Specifications /3 z45' svv h' 02. �6r2(24-aJ/7P �� OregofBesidentialfngineers dba Ukiah Engineering, Inc '.� _ 1730 SW Skyline Blvd., Ste 128 Portland, Oregon 97221 11, Phone 503-482-7045 -+-_. i www.0regon-Residential-Engineers.com Civil/Structural Engineers— Commercial and Residential— Single and Multifamily— Seismic Upgrades 13245 SW Ash St, Tigard, OR — Patio Deck Enclosed are calculations and structural submittal drawings for the building permit for the above referenced project. The following is included as part of this submittal: 1. All work is to be constructed per the 2017 Oregon Residential Specialty Code, a copy of which shall be on site at all times construction is underway. 2. Construction details as outlined in the 2017 Oregon Residential Specialty Code are included by reference in this document. 3. Geotechnical information is based on 2017 Oregon Residential Specialty Code minimums. �'" QFFIC' 4 COPY . ; F. EXPIRES:6 3c,.2,r1d Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 1 of 18 . .. ma. ASCE 7 Hazards Report AMERICAN SOCIETY OF CML tN FLMTi Address: Standard: ASCE/SEI 7-16 Elevation: 194.11 ft(NAVD 88) 13245 SW Ash Dr Risk Category: II Latitude: 45.424765 Portland, Oregon Soil Class: D - Default(see Longitude: -122.776506 97223 Section 11.4.3) 44, .:70c4.../„.71„, - 114-4,k,„,--,N1/4. -y .N7t,..-1; s w a •A• 17. Rr•tlnnJ wM ,yy(( 1 .f I y# t"-".mom 1 y' •-.,•, „, i -a �.. Wind Results: Wind Speed: 96 Vmph 10-year MRI 66 Vmph 25-year MRI 73 Vmph 50-year MRI 77 Vmph 100-year MRI 82 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1—CC.2-4 Date Accessed: Thu May 07 2020 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years(annual exceedance probability= 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Mountainous terrain, gorges, ocean promontories, and special wind regions should be examined for unusual wind conditions. httpsl/asce7hazardtool_online/ Page 1 of 6 Thu May 07 2020 Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 2 of 18 ASCE At n:AN SOCIETY OF CM MINEiHS Seismic Site Soil Class: D- Default(see Section 11.4.3) Results: SS : 0.856 So, : N/A Si : 0.394 TL : 16 Fe : 1.2 PGA : 0.39 F, : N/A PGA M : 0.472 SMS : 1.027 FpGA : 1.21 SM, : N/A le : 1 Sus : 0.685 C, : 1.228 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Thu May 07 2020 Date Source: USGS Seismic Design Maps https:l/asce7hazardtool.online/ Page 2 of 6 Thu May 07 2020 Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 3 of 18 ma. AMERICAN SOCIETY OF MIL ENUNEEM Ice Results: Ice Thickness: 1.50 in. Concurrent Temperature: 25 F Gust Speed: 30 mph Data Source: Standard ASCE/SEI 7-16, Figs. 10-2 through 10-8 Date Accessed: Thu May 07 2020 Ice thicknesses on structures in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Values provided are equivalent radial ice thicknesses due to freezing rain with concurrent 3-second gust speeds, for a 500-year mean recurrence interval, and temperatures concurrent with ice thicknesses due to freezing rain. Thicknesses for ice accretions caused by other sources shall be obtained from local meteorological studies. Ice thicknesses in exposed locations at elevations higher than the surrounding terrain and in valleys and gorges may exceed the mapped values. Snow Results: Elevation: Data Source: Date Accessed: Thu May 07 2020 In "Case Study"areas, site-specific case studies are required to establish ground snow loads. Extreme local variations in ground snow loads in these areas preclude mapping at this scale. Ground snow load determination for such sites shall be based on an extreme value statistical analysis of data available in the vicinity of the site using a value with a 2 percent annual probability of being exceeded (50-year mean recurrence interval). Site is outside ASCE/SEI 7-16, Table 7.2-7 boundaries. For ground snow loads in this area, see Structural Engineers Association of Oregon and PRISM Climate Group of Oregon State University. (2013). Snow Load Analysis for Oregon. 4th Ed. Statutory requirements of the Authority Having Jurisdiction are not included. https•lasce7hazardtool.online/ Page 3 of 6 Thu May 07 2020 Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 4 of 18 Rain Results: 15-minute duration: No Data 60-minute duration: No Data Data Source: NOAA National Weather Service, Precipitation Frequency Data Server,Atlas 14 jhttos://www.nws.noaa.gov/oh/hdsc/1 Date Accessed: Thu May 07 2020 For rainfall-event data in this area, see NOAA Hydrometeorological Design Studies Center, Current Precipitation Frequency Information and Documents for Oregon. htlps://asce7hazardtool.online/ Page 4 of 6 Thu May 07 2020 Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 5 of 18 AXE AMERICAN SOCIETY OF CA1 WINOS Flood Results: Flood Zone Categorization: X (unshaded) Base Flood Elevation: Refer to map for local elevations and interpolate according to the Authority Having Jurisdiction. Data Source: FEMA National Flood Hazard Layer-Effective Flood Hazard Layer for US, where modernized (https://msc.fema.gov/portal/search) Date Accessed: Thu May 07 2020 FIRM Panel: If available, download FIRM panel here Insurance Study Note: Download FEMA Flood Insurance Study for this area here ( • • a a • ' Tsunami Results: Tsunami: Not in mapped tsunami design zone. Data Source: ASCE Tsunami Design Geodatabase Date Accessed: Thu May 07 2020 https://asce7hazardtool.online/ Page 5 of 6 Thu May 07 2020 Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 6 of 18 ma AMERICAN SOCtlY Or CAW ENGINEERS The ASCE 7 Hazard Tool is provided for your convenience,for informational purposes only,and is provided"as is"and without warranties of any kind.The location data included herein has been obtained from information developed,produced,and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard.While ASCE has made every effort to use data obtained from reliable sources or methodologies,ASCE does not make any representations or warranties as to the accuracy,completeness,reliability, currency,or quality of any data provided herein.Any third-party links provided by this Tool should not be construed as an endorsement, affiliation,relationship,or sponsorship of such third-party content by or from ASCE. ASCE does not intend,nor should anyone interpret,the results provided by this Tool to replace the sound judgment of a competent professional,having knowledge and experience in the appropriate field(s)of practice,nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool,you expressly assume all risks associated with your use.Under no circumstances shall ASCE or its officers,directors, employees,members,affiliates,or agents be liable to you or any other person for any direct,indirect,special,incidental,or consequential damages arising from or related to your use of,or reliance on,the Tool or any information obtained therein.To the fullest extent permitted by law,you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https://asce7hazardtool.online/ Page 6 of6 Thu May 07 2020 Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 7 of 18 • Seismic Calculation in accordance with ASCE 7-16 12.14.8 Simplified Lateral Load Analysis 13245 SW Ash St., Tigard OR Ss:=.856 From ASCE Reference Seismic Design Category D Fa:=1.2 ASCE Hazard Analysis Sns:=(3)•Fa•Ss=0.685 It:=7 ASCE 7-16, Table 12.2-1 Line B.22 F:=1.0 ASCE 7-16; 12.14.8.1 V=Seismic Base Shear ASCE 7-16 Equation 12.14-12 W:=(28 ft•22 ft)•15 lb=(9.24.103) lb ft Vna e•=F•Sns •W=903.936 lb Roof Weight V ul V6ase =150.656 lb '= Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 8 of 18 • Project:321 12345 SWAsh StruCalc Version 10.0.1.6 5/15/20201:37:02 PM �� Location:Footing Size for Gravity Load / Footing o [2015 International Building Code(2015 NDS)] Footing Size:24.0 FT Round Diameter X 24.00 IN Deep Section Footing Design Adequate Location:Rafters Lower End Roof Rafter [2015 International Building Code(2015 NDS)] 1.5INx5.5INx10.19FT(9.5+0.7)1216O.C. #1-Douglas-Fir-Larch-Dry Use Section Adequate By:79.1% Controlling Factor:Moment Location:Rafters Upper End Roof Rafter [2015 International Building Code(2015 NDS)1 1.5INx5.5INx11.52FT(2+9.5)@16O.C. #1-Douglas-Fir-Larch-Dry Use Section Adequate By:51.3% Controlling Factor.Deflection Location:Roof Beam Center Multi-Span Combination Roof And Floor Beam [2015 International Building Code(2015 NDS)] 5.5 IN x 11.5 IN x 15.16 FT #1 -Douglas-Fir-Larch-Dry Use Section Adequate By:48.4% Controlling Factor:Deflection Location:Roof Beam Left Multi-Span Combination Roof And Floor Beam [2015 International Building Code(2015 NOS)] 5.5 IN x 11.5 IN x 15.16 FT #1 -Douglas-Fir-Larch-Dry Use Section Adequate By: 106.0% Controlling Factor.Deflection • Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 9 of 18 Project:321 12345 SWAsh StruCalc Version 10.0.1.6 5/15/2020 1:37:03 PM Page Location:Footing Size for Gravity Load Footing of [2015 International Building Code(2015 NDS)] Footing Size:24.0 FT Round Diameter X 24.00 IN Deep Section Footing Design Adequate CAUTIONS *Footing has been designed without reinforcement FOOTING PROPERTIES LOADING DIAGRAM Allowable Soil Bearing Pressure: Qs= 1500 psf Concrete Compressive Strength: F'c= 2500 psi Reinforcing Steel Yield Strength: Fy= 40000 psi Concrete Reinforcement Cover: c= 3 in FOOTING SIZE Diameter: Dia.= 24 ft Effective Depth to Top Layer of Steel: d= 22 in COLUMN AND BASEPLATE SIZE Column Type: Wood Column Width: m= 5.5 in Column Depth: n= 5.5 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Qu= 9 psf Effective Allowable Soil Bearing Pressure:Qe= 1200 psf Required Footing Area: Areq= 3.52 sf Area Provided: A= 452.39 sf Baseplate Bearing: Bearing Required: Bear= 6066 lb Allowable Bearing: Bear-A= 70709 lb Beam Shear Calculations(One Way Shear): Beam Shear: Vu1 = 2510 lb lsLe in Allowable Beam Shear: Vc1 = 205888 lb T Punching Shear Calculations(Two Way Shear): 2 1 n Critical Perimeter. Bo= 110 in 24 ft Punching Shear: Vu2= 5996 lb Controlling Allowable Punching Shear: vc2= 177023 lb Bending Calculations: FOOTING LOADING Factored Moment: Mu= 193531 in-lb Live Load: PL= 2499 lb* Nominal Moment Strength: Mn= 2830963 in-lb Dead Load: PD= 1723 lb* NOTES Total Load: PT= 4222 lb* Ultimate Factored Load: Pu= 6066 lb Footing plus soil above footing weight: Wt= 87462 lb *Load obtained from Load Tracker.See Summary Report for details. Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 10 of 18 Project:321 12345 SW Ash S[mCalc Version 10.0.1.E 5/75/2020 1:37:03 PM e Location:Rafters Lower End Roof Rafter of [2015 International Building Code(2015 NOS)] 1.5 IN x 5.5IN x 10.19 FT(9.5+0.7)@ 16 0.C. #1-Douglas-Fir-Larch-Dry Use Section Adequate By:79.1% Controlling Factor:Moment DEFLECTIONS Center Right LOADING DIAGRAM Live Load 0.18 IN U647 0.00 IN 2L/19378 Dead Load 0.11 in 0.00 in Total Load 0.29 IN U404 0.00 IN 2Ulnfinity Live Load Deflection Criteria:U240 Total Load Deflection Criteria:U180 REACTIONS A Live Load 159 lb 182 lb Dead Load 96 lb 111 lb Total Load 255 lb 293 lb Bearing Length 0.27 in 0.31 in SUPPORT LOADS A B _ Live Load 119 plf 137 plf Dead Load 72 pif 83 pif -- - ---esz n- - - - l¢s7ft plfFFF999 Total Load 191 plf 220 plf MATERIAL PROPERTIES #1-Douglas-Fir-Larch RAFTER DATA Interior Eave Base Values Adiusted Span Length 9.52 ft 0.67 ft Bending Stress: Fb= 1000 psi Fb'= 1719 psi Rafter Pitch 2 :12 Cd=1.15 CF=1.30 Cr=l.15 Roof sheathing applied to top of joists-top of rafters fully braced. Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Duration Factor 1.15 Cd=1.15 Peak Notch Depth 0.00 Modulus of Elasticity: E= 1700 ksi E'= 1700 ksi Base Notch Depth 0.00 Comp.1 to Grain: Fc-1= 625 psi Fc-1'= 625 psi RAFTER LOADING Controlling Moment 605 ft-lb Uniform Roof Loading 4.764 Ft from left support of span 2(Center Span) Roof Live Load: LL= 25 psf Created by combining all dead loads and live loads on span(s)2 Roof Dead Load: DL= 15 psf Controlling Shear. 233 lb Slope Adjusted Spans And Loads supportLeft Span: L-adj= 0 ft At a distance d from right of span 2(Center Span) Interior Span: L-adj= 9.65 ft Created by combining all dead loads and live loads on span(s)2,3 Eave Span: L-Eave-adj= 0.68 ft Left Live Load: wL-adj= NaN plf Comparisons with required sections: Req'd Provided Interior Live Load: wL-adj= 32 Of Section Modulus: 4.22 in3 7.5E in3 Eave Live Load: wL-Eave-adj= 32 plf Area(Shear): 1.69 in2 8.25 in2 Left Dead Load: wD-adj= NaN plf Moment of Inertia(deflection): 9.27 in4 20.8 in4 Interior Dead Load: wD-adj= 20 pif Moment: 605 ft-lb 1 D83 ft-lb Eave Dead Load: wD-Eave-adj= 20 plf Shear: -233 lb 1139 lb Left Total Load: wT-adj= NaN pit NOTEZ Interior Total Load: wT-adj= 52 plf Eave Total Load: wT-Eave-adj= 52 riff Job 322 13245 SW Ash.St Patio Cover 5/15/2020 Page 11 of 18 Project:321 12345 SW Ash StruCalc Version 10.0.1.6 5/15/2020 1:37:04 PM Page Location:Rafters Upper End Roof Rafter or [2015 International Building Code(2015 NDS)] 1.5IN x 5.5 IN x 11.52 FT(2+9.5)@ 16 0.C. #1-Douglas-Fir-Larch-Dry Use Section Adequate By:51.3% Controlling Factor:Deflection DEFLECTIONS Left Center LOADING DIAGRAM Live Load -0.12 IN 2L/404 0.18 IN L/647 Dead Load -0.06 in 0.10 in Total Load -0.18 IN 2L/272 0.28 IN L/419 Live Load Deflection Criteria:L/240 Total Load Deflection Criteria: U180 REACTIONS A Live Load 232 lb 159 lb Dead Load 141 lb 92 lb Total Load 373 lb 251 lb Bearing Length 0.40 in 0.27 in SUPPORT LOADS A B F Live Load 174 Of 119 plf -_-- -- Dead Load 106 plf 69 plf 2ft 9.52n Total Load 280 Of 188 plf MATERIAL PROPERTIES #1-Douglas-Fir-Larch RAFTER DATA Left Interior Base Values Adjusted Span Length 2 ft 9.52 ft Bending Stress: Fb= 1000 psi Fb'= 1719 psi Rafter Pitch 2 :12 Cd=1.15 CF=1.30 Cr-1.15 Roof sheathing applied to top of joists-top of rafters fully braced. Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Duration Factor 1.15 Cd=1.15 Peak Notch Depth 0.00 Modulus of Elasticity: E= 1700 ksi E'= 1700 ksi Base Notch Depth 0.00 Comp.-L to Grain: Fc- = 625 psi Fc--L'= 625 psi RAFTER LOADING Uniform Roof Loading Controlling Moment: 587 ft-lb Roof Live Load: LL= 25 psf 4.853 Ft from left support of span 2(Center Span) Roof Dead Load: DL= 15 psf Created by combining all dead loads and live loads on span(s)2 Slope Adjusted Spans And Loads Controlling Shear: 243 lb Left Span: L-adj= 2.03 ft At a distance d from left support of span 2(Center Span) Interior Span: L-adj= 9.65 ft Created by combining all dead loads and live loads on span(s)1,2 Eave Span: L-Eave-adj= 0 ft Comparisons with required sections: Rea'd Provided Left Live Load: wL-adj= 32 plf Section Modulus: 4.1 in3 7.56 in3 Interior Live Load: wL-adj= 32 plf Area(Shear): 1.76 in2 8.25 in2 Eave Live Load: wL-Eave-adj= NaN plf Left Dead Load: wD-adj= 20 plf Moment of Inertia(deflection): 13.74 in4 20.8 in4 Interior Dead Load: wD-adj= 20 ptf Moment: 587 ft-lb 1083 ft-lb Eave Dead Load: wD-Eave-adj= NaN plf Shear: 243 lb 1139 lb Left Total Load: wT-adj= 52 plf NOTES Interior Total Load: wT-adj= 52 plf Eave Total Load: wT-Eave-adj= NaN plf Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 12 of 18 Project:321 12345 SW Ash StruCalc Version 10.0.1.6 5/15/2020 1:37:05 PM Page Location:Roof Beam Center Multi-Span Combination Roof And Floor Beam a [2015 International Building Code(2015 NOS)] 5.5 IN x 11.5 IN x 15.16 FT #1-Douglas-Fir-Larch-Dry Use Section Adequate By:48.4% Controlling Factor.Deflection DEFLECTIONS Left Center Right LOADING DIAGRAM Live Load -0.12 IN 2U594 0.21 IN L/873 -0.12 IN 2U594 Dead Load -0.08 in 0.14 in -0.08 in Total Load -0.20 IN 2U356 0.35 IN U524 -0.20 IN 2U356 Live Load Deflection Criteria:U360 Total Load Deflection Criteria:U240 REACTIONS A @ Live Load 2499 lb 2499 lb Dead Load 1664 lb 1664 lb Total Load 4163 lb 4163 lb Bearing Length 1.21 in 1.21 in BEAM DATA Left Center Right Span Length 2.92 ft 15.16 ft 2.92 ft __ __.� Unbraced Length-Top O ft O ft O ft F-2.92ft t -15.19ft 41: 2.92 ft-1 Unbraced Length-Bottom 1 ft 15 ft 0.7 ft Notch Depth 1.00 MATERIAL PIRTIES ROOF LOADING Left Center Riaht #1-Douglas-Fir-Larch Live Load RLL= 25 psf 25 psf 25 psf Base Values Adiusted Dead Load RDL= 15 psf 15 psf 15 psf Bending Stress: Fb= 1350 psi Fb'= 1553 psi Tributary Width Side One TW1= 4.8 ft 4.8 ft 4.8 ft Cd=1./5 CF=1.00 Tributary Width Side Two TW2= 4.8 ft 4.8 ft 4.8 ft Shear Stress: Fv= 170 psi Fv'= 196 psi FLOOR LOADING ]weft Center Right Cd=1.15 Live Load FLL= 40 psf 40 psf 40 psf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Dead Load FDL= 15 psf 15 psf 15 psf Comp.1 to Grain: Fc-1= 625 psi Fc-1'= 625 psi Tributary Width Side One TW1 = 0 ft 0 ft 0 ft Tributary Wtdtli Side Two TW2= 0 ft O ft O ft Controlling Moment 970011-lb Wall Load WALL= 0 pit 0 plf 0 pit 7.58 Ft from left support of span 2(Center Span) BEAM LOADING Left Center Riaht Created by combining all dead loads and live loads on span(s)1,2,3 Roof Uniform Live Load: 238 plf 238 Of 238 plf Controlling Shear. -2645 Ib Roof Uniform Dead Load: 145 plf 145 Of 145 plf At a distanced from right support of span 2(Center Span) Floor Uniform Live Load: 0 plf 0 plf 0 plf Created by combining all dead loads and live loads on spans)1,2,3 Floor Uniform Dead Load: 0 plf 0 plf 0 plf Co Self Weight: Comparisons with required sections: Rea'd Provided Section Modulus: 74.98 in3 121.23 in3 Combined Uniform Live Load: 238 Of 238 Of 238 plf 14 plf 14 plf 14 plf Combined Uniform Dead Load: 158 ptf 158 plf 158 plf Area(Shear): 20.29 in2 63.25 in2 Moment of Inertia(deflection): 469.87 in4 697.07 in4 Combined Uniform Total Load: 396 pH 396 plf 396 plf Moment: 9700 ft-lb 15684 ft-lb Shear. -2645 lb 8244 lb NOTES Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 13 of 18 • Papa Project:321 12345 SWAsh StruCalc Version 10.0.1.6 5/15/2020 1:37:06 PM Location:Roof Beam Left Multi-Span Combination Roof And Floor Beam of [2015 International Building Code(2015 NOS)] 5.5 IN x 11.5 IN x 15.16 FT #1-Douglas-Fir-Larch-Dry Use Section Adequate By:106.0% Controlling Factor:Deflection DEFLECTIONS Left Center Riaht LOADING DIAGRAM Live Load -0.08 IN 2U836 0.15 IN U1229 -0.08 IN 2U836 Dead Load -0.06 in 0.10 in -0.06 in Total Load -0.14 IN 2U494 0.25 IN U728 -0.14 IN 2L/494 Live Load Deflection Criteria:U360 Total Load Deflection Criteria:U240 REACTIONS A Live Load 1775 lb 1775 lb Dead Load 1223 lb 1223 lb Total Load 2998 lb 2998 lb Bearing Length 0.87 in 0.87 in BEAM DATA Left Center Riaht Span Length 2.92 ft 15.16 ft 2.92 ft Unbraced Length-Top O ft O ft O ft F-292e T 15,16ft 12.92ft-{ Unbraced Length-Bottom 1 ft 15 ft 0.7 ft AAA ttttYYYY Notch Depth 1.00 MATERIAL PIRTIE$ ROOF LOADING )_eft Center Riaht #1-Douglas-Fir-Larch Live Load RLL= 25 psf 25 psf 25 psf Base Values Adjusted Dead Load RDL= 15 psf 15 psf 15 psf Bending Stress: Fb= 1350 psi Fb'= 1553 psi Tributary Width Side One TW1= 2 ft 2 ft 2 ft Cd=1.15 CF=1.00 Tributary Wdth Side Two TW2= 4.8 ft 4.8 ft 4.8 ft Shear Stress: Fv= 170 psi Fv'= 196 psi FLOOR LOADING Left Center Riaht Cd=1.15 Live Load FLL= 40 psf 40 psf 40 psf Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Dead Load FDL= 15 psf 15 psf 15 psf Comp.-Lto Grain: Fc--L= 625 psi Fc = 625 psi Tributary Wdth Side One TW1= 0 ft 0 ft 0 ft Tributary Width Side Two TW2= 0 ft O ft O ft Controlling Moment 6985 ft-lb Wall Load WALL= 0 plf 0 plf 0 plf 7.58 Ft from left support of span 2(Center Span) BEAM LOADING j�ft Center Riaht Created by combining all dead loads and live loads on span(s)1,2,3 Roof Uniform Live Load: 169 pH 169 pH 169 pH Controlling Shear. -1904 lb Roof Uniform Dead Load: 103 pH 103 pH 103 pH At a distanced from right support of span 2(Center Span) Floor Uniform Live Load: 0 pH 0 pH 0 pH Created by combining all dead loads and live loads on span(s)1,2,3 Floor Uniform Dead Load: 0 Of 0 pH 0 pH Comparisons with required sections: Read Provided Combeam n Self Weight: 14 pH 14 pit 14 pH Section Modulus: 53.99 in3 121.23 in3 Combined Uniform DeadLiea Load: 117 pH 1691 pH 11769 pH Area(Shear): 14.61 in2 63.25 in2 Combined Uniform Load: 117 pH 117 pH 117 pH Moment of Inertia(deflection): 338.36 in4 697.07 in4 Combined Uniform Total Load: 286 pH 286 pH 286 pH Moment: 6985 ft-lb 15684 ft-Ib Shear. -1904 lb 8244 lb NOTES Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 14 of 18 • Project:321 12345 SW Ash StruCalc Version 10.0.1.6 5/15/2020 1:38:05 PM page Location:Cols(Embedded) Column or [2015 International Building Code(2015 NDS)] 5.5 IN x 5.5 IN x 9.0 FT #1-Douglas-Fir-Larch-Dry Use Section Adequate By:46.7% Footing Design Adequate CAUTIONa *This column has been designed as a cantilever. *The design results are a lateral force only.Vertical force design for a footing and/or collar are to be designed separately. DEFLECTIONS LOADING DIAGRAM-Embedded Column Deflection due to lateral loads only: Deft= 0 IN=L/MAX Live Load Deflection Criteria: L/180 VERTICAL REACTIONS Live Load: Vert-LL-Rxn= 2499 lb Dead Load: Vert-DL-Rxn= 1723 lb Total Load: Vert-TL-Rxn= 4222 lb HORIZONTAL REACTIONS Total Reaction at Top of Column: TL-Rxn-Top= 0 lb 9 n Total Reaction at Bottom of Column: TL-Rxn-Bottom= 151 lb COLUMN DATA Total Column Length: 9 ft A Unbraced Length(X-Axis)Lx: 9 ft Unbraced Length(Y-Axis)Ly: 9 ft LOADING DIAGRAM-Round Footing Column End Condition-K(e): 2.1 Axial Load Duration Factor 1.00 Lateral Load Duration Factor(Wind/Seismic) 1.33 COLUMN PROPERTIES #1-Douglas-Fir-Larch Base Values Adjusted *Sin Compressive Stress: Fc= 1000 psi Fc'= 262 psi Cd=1.00 Cp=0.26 Bending Stress(X-X Axis): Fbx= 1200 psi Fbx'= 1200 psi 2 ft Cd=1.00 CF-1.00 Bending Stress(Y-Y Axis): Fby= 1200 psi Fby'= 1200 psi Cd=1.00 CF=1.00 Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi I 2e I Column Section(X-X Axis): dx= 5.5 in Column Section(Y-Y Axis): dy= 5.5 in AXIAL LOADING Area: A= 30.25 in2 Live Load: PL= 2499 lb* * Section Modulus(X-X Axis): Sx= 27.73 in3 Dead Load: PD= 1664 lb Section Modulus(Y-Y Axis): Sy= 27.73 in3 Column Self Weigh: CSW= 59 lb Slenderness Ratio: Lex/dx= 41.24 Total Axial Load: PT= 4222 lb Ley/dy= 41.24 *Load obtained from Load Tracker.See Summary Report for details. Column Calculations(Controlling Case Only): LATERAL LOADING (Dy Face) Controlling Load Case:Axial Total Load Only(L+D) Uniform Lateral Load: wL-Lat= 0 plf Actual Compressive Stress: Fc= 140 psi Point Load: One Allowable Compressive Stress: Fc'= 262 psi Live Load: 151 lb Eccentricity Moment(X-X Axis): Mx-ex= 0 ft-lb Location: 8.9 ft Eccentricity Moment(Y-Y Axis): My-ey= 0 ft-lb Embedded Footing Properties Moment Due to Lateral Loads(X-X Axis): Mx= 0 ft-lb Footing VMdth: 2 ft Moment Due to Lateral Loads(Y-Y Axis): My= 0 ft-lb Footing Depth: 2 ft Bending Stress Lateral Loads Only(X-X Axis):Fbx= 0 psi Depth Required: 0.55 ft per IBC Equation 18-1 (Non-constrained) Allowable Bending Stress(X-X Axis): Fbx'= 1200 psi Bending Stress Lateral Loads Only(Y-YAxis): Fby= 0 psi Allowable Bending Stress(Y-YAxis): Fby'= 1200 psi Combined Stress Factor: CSF= 0.53 NOTES Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 15 of 18 • page Co d a er$yu}mmaryryAs StruCalc Version 10.0.1.6 5/15/2020 11:41:02 AM oMmn- x 5.5 IN z 9.87 FT #1-Douglas-Fir-Larch-Dry Use Axial Load Roof Seam Center Reaction A:LL= 2499 lbs DL= 1664 lbs TL= 4163 lbs of j Footing Size for Gravity Load Footing-Size: 3.75 FT Round Diameter 30.00 IN Deep Footing Load Cols(Embedded) Reaction A:LL= 2499 lbs DL= 1729 lbs TL= 4228 lbs Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 16 of 18 • General Notes 1. All work to be performed in accordance with the 2017 19.Use lightweight equipment to compact the soil within Oregon Residential Specialty Code,a copy of which 2 feet around foundations.Excavation shall be shall be on site while work is being performed.Refer to properly back filled. code for additional details that may not be shown on 20.Roof and area drainage shall be directed away from these drawings. the foundation. 2. The scope shall include but not be limited to the 21.All wood exposed to the weather or in contact with furnishing of all labor,materials,and equipment concrete or masonry shall be pressure treated or necessary to complete the work shown or inferred by protected with a waterproof membrane.Newly any and all of the documents included in this permit exposed surfaces resulting from field cutting,boring or submittal, handling shall be field treated in accordance with 3. All certifications demonstrating the project's AWPA M-4. compliance with these permit documents shall be in 22.The constructor shall maintain a copy of the Simpson writing and maintained in project files which shall be Catalog and Simpson Installation Manual on site at all made available upon request times and shall install all Simpson connections in 4. Provide manufacturers approved product evaluation accordance with the installation manual. reports and a list of all proposed substitutes to the 23.All wood framing shall be Structural Grade Doug Fir or engineer for review and approval. better unless otherwise noted on the drawings. 5. These drawings and specifications represent the Comply with PS 20,American softwood lumber finished structure and do not indicate means, standard and standard grading rules for western methods,procedures,or sequence of construction. lumber. 6. The constructor shall take necessary precautions to 24.The moisture content of any wood installed in this maintain and ensure the integrity of the new and any project shall be no greater than 19%. existing structures during construction.The design 25.All wood members shall be stamped showing wood stresses on any element shall not be exceeded during grading and the grading agency.Any material used in construction. this project which does not exhibit this stamp shall be 7. Constructor only shall be responsible for or enforce examined by an appropriately certified professional any safety measures or regulations.Constructor shall who shall verify that the material meets the Structural design,construct,and maintain all safety devices, Grade Doug Fir standard or better.Such certification including shoring and bracing for the new and existing shall be in writing and available as needed or structures,and shall be solely responsible for requested. conforming to all local state and Federal safety and 26.All Timbers to be FSC rated. health standards,laws,and regulations. 27.All materials to be low VOC and non-urea 8. Obtain prior approval in writing for any changes to the formaldehyde. drawings. 28.All exposed steel timber hardware fasteners and 9. The constructor shall review and compare the connectors shall be galvanized.Connector hardware structural drawings with any other construction models are those for the Simpson Strong Tie Company. documents and the actual conditions and bring any Size and number of nails,screws,or bolts to be per discrepancies to the attention of the owner and manufacturers specifications. engineer. 29.Nails shall be common wire unless otherwise noted. 10.Do not scale drawings. The use of machine nailing is subject to satisfactory 11.The constructor shall verify dimensions,elevations and performance. all information,and report in writing any 30.All bolts to maintain a distance of not less than seven inconsistencies,errors,or omissions to the engineer bolt diameters from end and four bolt diameters from before proceeding with the work. edge of member. 12.Any substitutions for structural members,hardware or 31.Lag screws clearance and lead/pilot holes shall be details shall be reviewed by the engineer.Such review bored in two stages.Clearance hole for the shank shall will be prepaid by the general contractor with no have the same diameter as the shank.Clarence hole guarantee that the substitution will be allowed. shall be the same depth of penetration as the length of 13.All communication shall be in writing.No verbal the shank.The lead hole for the threaded portion shall communications,decisions,instructions,approvals have a diameter equal to 70%of the shank diameter shall be valid. and the length equal to at least the length of the 14.All construction shall be inspected by the building threaded portion. officials according to the codes applicable to the 32.Nailed or screwed hold down anchors shall be installed location of the project. per manufactures approved product evaluation report. 1S.Minimum compressive strength of concrete shall be as 33.In the event of any discrepancy between these noted on drawings. documents and the documents referenced in 16.All reinforcing steel shall be ASTM A615 Grade 60. Paragraph 2,the references in paragraph two shall 17.In the event that temperatures are above 80'F hot prevail. weather concrete procedures according to ACI 305R shall apply.When the average air temperatures are below 40'F,Cold weather concreting procedures according to ACI 306R shall apply. 18.Lacking an owner furnished geotechnical investigation, the foundation has been design based on the ORSC specified minimum bearing capacity of 1500 psf.ORE dba Ukiah Engineering,Inc.is not responsible for any future defects resulting from site conditions that may vary from the above assumption. Job 322 13245 SW Ash St Patio Cover SO1512020 Page 17 of 18 . 2'-I1" .! CoI — 1 —. Col---, Col Ftg Col Ftg- lider 21' 15 2" Existing Home /Col Ftg Col Ftg\ 2 � —. 2'_32"— 19'_2" 1 —8" 22' Plan View 2X6Q16"O.C. Roof Rafters;Sloped 2:12 X 12#1 Roof Beam Existing Home Col 6 X 6(typ)-2 — — Embedded X into footing mbed column 'i�— r.i ,�� to within 2" I _ of bottom Col Footin . 2'dia X 2'Deep 2500 psi(typ) End View 13245 SW Ash Patio Deck ROregoial Engineers tans Job 322 13245 SW Ash St Patio Cover 5/15/2020 Page 18 of 18