Plans SOLAR
COMBINER
Array of 9 modules and Inverter Gable �� -.1QA
Black-L1
91Q7X-96-2-US Microinverters Red-L2 JBox I, A
\ Green Ground N
, O 1/
�� #10 Awg THHN „ 15A \
CD O PV PV 3/4'EMT or FMC
HHN
Module Module Ground#6Awg * MT or FMC
Distance 25 H 3/G EMT# FMC
Q ^^ I Ground#BAwgg
Distance 5 ft
L 't3
LT IV
CO = Array of 5 modules and Inverter Cable
' " tr) 5I07X-96-2-US Microinverters Black-L2 JBox n
(....7Green Ground\ N I xi --4
Z Z O m -{ oom •
001 1, v '
-ncm - 0Q)
#10 Awg THHN �) m XI O (� C o " rj
PV 3/4•EMT or PMC el,
m Z O _ O
Module Module Ground#6 Awg ` j vJ
Distance 10 n ril O +O m r Z z -1
r -1C) 'V
n Pmmz [nOm ®
13
C 0 -1 Array of 5 modules and Inverter Gable
Q r- Q C D m
SZ3 CD m- 5107X-96-2-US Microinverters Red-L2 JBox - m m m .�y
C73 CD
\ Green Ground\ O _ m w^
(D Q D #10 Awg THHN 2 00 000PV PV 3/4"EMT or FLAG ~
CO PV
Module Ground#6 Awg at fa
Distance A
Q. Distance 5 •• v.,mac 4 ..
--t -• .....I 3, •••••••• lei
-� 0 0 ---I howlpr. -2.:o �. )
TableQ8 Internal Q Cable VRise(Landscape 60 Cell Cable Q-12-17-240 d \ it 0 i!%' No ':a iII
rw
IQ7 Microinverters per branch [p •= ry .0 L .J
.. vX --,
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Pagel of
Ni
Job: Address:
Current(A) 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10 11 12 13 14 15 16
9, Elin&Paul Teyler
PNW0259 14777 SW 80th Ave
VRise(V) 0.03 0.08 0.16 0.26 0.39 0.55 0.73 0.94 1.17 1.43 1.71 2.03 2.36 2.73 3.12 3.53
n Tigard OR 97224
VRise(%) 0.01 0.03 0.06 0.11 0.16 0.23 0.30 0.39 0.49 0.60 0.71 0.84 0.99 1.14 1.30 1.47
til
PIV V'/ S o1ar
Utility Meter
e
m=9lm
200A
Westinghouse
BR \
200A --{
•
1_iM� i
-;�811 35A
n
PV Module Ratin 9 3f4s /48 AWGTrFMC
"EMT or FMC
Manufacture: Panasonic Ground #6 AWG
Model#:VBHN325SA17 Total number of Modules: 19 Distance 5'
Open-Circuit Voltage: 69.6V System Size:6.18 kW
Operation Voltage: 57.6V Inverter Specs:
Max String Voltage: 600V Manufacture:Enphase
Operating Current: 5.65A Module: IQ7X-96-2-US
Short-Circuit Current: 6.03A Max Output Current: 1.31A NEC 690.54 AC Point of
Max Series Fuse: 15A Nominal Output Volts: 240V Interconnection
Maximum Power(STC):325W Output Frequency: 47Hz-68Hz Rated AC Output: 24.89 Amps
Power Tolerance: +/-10% Output Volt Range:211V-264V Nominal AC Voltage: 240 Vac
New Solar System
240Vac Voltage Drops
Description Current(A) Wire Size(Awg) Distance(feet) Percent(%)
Trunk Cable 0.49 Page 2 of 3
Array to Combiner 11.79 10 25 0.29 Job: Address:
Combiner to Main 24.89 8 5 0.08 Elin&Paul Teyler
PNW0259 14777 SW 80th Ave
Tigard OR 97224
Total 0.86
PNW Solar
Circuit Map
❑ ❑ ❑ ❑ ❑
2 2 2 2 2
2 2 2 2
1 1 1 1 1 1 1
O
1 1 1
Page 3 of 3
Job: Address:
Elfin & Paul Teyler
PNW0259 14777 SW 80th Ave
Tigard OR 97224
PNW Solar
A
Plot
135'
Home °'
Q
0
co
56' C/)
XDriveway
Mainpanel /'/
Utility Meter
Combiner Panel
. 12" Section 3111.4.8.1
Spans Elevation <18" Section 3111.5.3.5
Weight of solar < 4.5 lb/sqft
Spans comply with 2308.7.2
2x8 rafters 24" OC 35°
6:12, comp roof, one layer 26'
Ground to Eave Ground to Peak
2x8 rafters 24"OC
Page 1 of 3
1101.11.111111111
Job: Address:
2x8 'oists 24"OC Elin & Paul Teyler
PNW0259 14777 SW 80th Ave
11, Tigard OR 97224
PNW Solar
Detail
Attic
z12" Section 3111.4.8.1 Vents
DOD DO
36" Pathway Section 3111.3.4.8.4
(smoke vents)
Suneye#1 r� Vent / 12" Section 3111.4.8.1
Pipe
0
GG� Heat
62 Ve0nt
-41 .5 "
a)
Suneye Legend (degrees): Solar Array Coverage:
1. Tilt = 35 Azimuth = 180 Solar Array sgft = 343
Roof Surface sgft = 3175
Solar Array covers 11% of roof surface
Solar Array Setbacks: Page 2 of 3
>_12" along all horizontal ridges per OSSC 3111.4.8.1 Job: Address:
36" heat vent clearance per OSSC 3111.3.4.8.4
Elfin & Paul Teyler
Solar Array Attachments: Solar racking attachments per PNW0259 14777 SW 80th Ave
3111.3.5.3.3 24" OC within 3' of edge hip eave or ridge, 48' Tigard OR 97224
OC elsewhere
I IVW Solar
2x framing
24" Max on Center
Solar Pane
4.5PSF maxl�
I""'`"". , a '4
Panel connected
to rails with 1 connector ``
for each 8 Sq feet or less II, '
per rack manufacturer's specs
Aluminum Rails to alternate---------
roof framing 4' OC max.
Two rails per min. per panel
Panels 41 .5" X
62.6" aprox.
2X joist/truss to meet
Oregon Solar code span
requirements /84
Max
Min 16" SS lag embedded 2" min 2 Layers or less
center of framing member Y
of roof material
lashed and sealed
roof penetration
Page 3 of 3
Job: Address:
Elfin & Paul Teyler
PNW0259 14777 SW 80th Ave
Tigard OR 97224
PNW Solar
Oregon Pathways & Holdowns
Attic
12" Vents
/00
o O 0
E
am
Vent
co
Pipe 12"
0 0 0 0 0 0
O 0 0 0
0 0 0 0 T
Heat
Flue
o 0
0 0 0 0 0 0 0 0 38"
O 0 0 0
O 0 0 0 0 c
Oregon pathways and setbacks in green
Hold downs in red
Installers:
35 deg comp roof, Westinghouse panel, install 35A breaker in main panel,
bring slim 15A breakers, install generator connection system with plug-in on
exterior of garage wall, work with client to determine circuits to dedicate to
transfer panel.
Job: Address:
Elfin & Paul Teyler
PNW0259 14777 SW 80th Ave
Tigard OR 97224
I IVW Solar