Report Msi2ozo- oot`ts. City of Tigard Building,Division 2020 13125 SW Hall Blvd,Tigard,OR 97223 {2- �b l Phone: 503.718.2439 Fax 503.598.1960 Cif�Y�N���1 sa � r'f-,^�,i t{ ( i T I G A R D Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: f4777 6vv 630Tik Avt City: T1 e ' Zip: q 7Z zi Owner's Name: i;Li N F' t t_ TeY" Date: f . 0 , Contractor's Name: =;i2,4_rr; T 5e.fautc cL CCB #: ( . ' jZ Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation E Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? —o OSSC or ORSC for design requirements. Wind Ex osure Erc Is the wind exposure es If"Yes", qualifies for p "C"or less? n No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes Er-Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than E Yes the prescriptive path. above ❑ No 1 l:fBuildin&Forms/PhotoVoftaic-Checklist02-01-11.docx Is the construction material wood and does Yes Type of e If"Yes", qualifies for the construction qualify Construction as "conventional light C No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for [ Yes the prescriptive path. ❑ No Is the combined weight Er Yes of the PV modules and If"Yes", qualifies for racking less than or C No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation [ Yes layout in accordance If"Yes", qualifies for with Section 305.4(3) of the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of of wood one of the three types material roofing material shingle/shake checked, qualifies for E ofax. two layers the prescriptive path. composition shingle. Is the roof mountedEr—Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ❑ No the prescriptive path. to the roof framing or blocking directly? '1 7 I:/Buildin8'Forms/PhotoVoltaic-Checklist02-01-11.doca 2 I Is the gauge 26 or less? E Yes If"Yes", gralifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes",qualifies for ❑ Yes the prescriptive path. ❑ No ,. Min'' um Uplift rating o Clamps? 75 lbs fo 8 inches spac g or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted If the spacing falls Spacing clami�s? inimum 24 inches within 24 inches and 60 solar systems p g of , directly to inches M: urn 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel " panels? 18 inches • less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of f"Yes", qualifies for fastener? El Yes t' prescriptive path. C No Is the roof decking of WSP min. 'A"thickness, P Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails 6"/1.2"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 i1Building'Forms/PhotoVoltaic-Checkiist02-01-1 l,docx Submittal Documents required for Prescriptive Installations Show the locationon of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV, IVIodul.es Manufacturer: P,a ,7 .A.;y Model Number: t/g ftel 3z5"5 A 1 t7 Listing Agency: L L / 70,3 4 I:/Building/Fonns/PhotoVoltaic-Checkli siO2-01-I 1.docx