Report City of Tigard RECEI\ID , '' Building Division 13125 SW Hall Blvd, Tigard, OR 97223 MAY 1 E` Phone: 503.718.2439 Fax: 503.598.1960 CITY of l T I GARD Inspection Line: 503.639.4175 BUILDING DMVI&ON www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: l 0["j 04 s vv i\1 ot, ve S-- City: 1103atx Zip: 97224 Owner's Name: Date: Contractor's Name: TESLA CCB #: 180498 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation ❑ Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Is the wind exposure El Yes If"Yes", qualifies for Wind Exposure "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for ® Yes the prescriptive path. above ❑ No 1 I:Building/Forms/Photo Voltaic-Checklist.docx Is the construction El material wood and does Yes Type of If"Yes", qualifies for the construction qualify Construction as"conventional light ❑ No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. ElYes If"Yes", qualifies for the prescriptive path. No Roof framing members Is the spacing 24 inches or less? 7 " if"Yes", qualifies for Nominal lumber. ® Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance Yes If"Yes", qualifies for with Section 305.4(3) of the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. // of composition shingle. Is the roof mounted ® Yes Connections of solar assembly the solar assembly connected to roof No If"Yes",prescriptiveqp p for to the roof framing or blocking ❑ the path. directly? 2 (:Building/Forms/PhotoVoltaic-Checkl ist.docx Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? El Yes "Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? El Yes the prescriptive path. ❑ No Is the roof decking of WSP min. Y2" thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof El Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/PholoV oltai c-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Model Number: 260 Listing Agency: UL1703 4 I:/Build ing/Forms/PhotoVoltaic-Checklist.docx Branden Taggart From: Branden Taggart Sent: Wednesday, May 20, 2020 1:21 PM To: Melissa Farias Subject: Permit Submittal for 10504 SW Naeve St. Attachments: Branden Taggart2.vcf;Transmittal Letter_Revisions_052512.pdf; RegPermitAction_ 120518.pdf Hi Melissa, We received your submittal for the "downsized" solar photovoltaic system for Ann Tran, located at 10504 SW Naeve Street. However,we will need to receive (1)completed transmittal letter to revise the permit and (1) Request for Permit Action form for the electrical permit fee refund. Both forms are attached above. Feel free to email this back to me, and I will route these changes to our Plans Examiner. Please note that refunds are processed within 4-6 weeks, and the refund will be received in the form of a check. Please let me know if you have questions. Thank you, IN Brendan Taggart ' City of Tigard R Senior Permit Technician TU3AkD Community Development 13125 SW Hall Blvd Tigard, OR 97223 (503)718-2449 brandent@tigard-or.gov 1 RECEIVED MAY 1 9 2020 Hi City of Tigard O CITY OF TIGARD BUILDING DIVISION We originally submitted for this permit as a 7.56 KW, however the customer decided to downsize the system to a 3kw. lye attached all new plans/apps just in case it's needed. Feel free to use whats needed to make the adjustments to the permit, and shred the rest. Permit: MST20205-00083