2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: l 0["j 04 s vv i\1 ot, ve S--
City: 1103atx Zip: 97224
Owner's Name: Date:
Contractor's Name: TESLA CCB #: 180498
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ® No OSSC or ORSC for
design requirements.
Is the wind exposure El Yes If"Yes", qualifies for
Wind Exposure "C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
® Yes the prescriptive path.
above
❑ No
1
I:Building/Forms/Photo Voltaic-Checklist.docx
Is the construction
El
material wood and does Yes
Type of If"Yes", qualifies for
the construction qualify
Construction as"conventional light ❑ No the prescriptive path.
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ElYes If"Yes", qualifies for
the prescriptive path.
No
Roof framing
members Is the spacing 24 inches
or less?
7 " if"Yes", qualifies for
Nominal lumber. ® Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance Yes If"Yes", qualifies for
with Section 305.4(3) of
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
// of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly
the solar assembly connected to roof No If"Yes",prescriptiveqp p for
to the roof framing or blocking ❑ the path.
directly?
2
(:Building/Forms/PhotoVoltaic-Checkl ist.docx
Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
El Yes
"Yes", qualifies for
Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
prescriptive path.
standing seam
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? El Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. Y2" thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof El Yes the prescriptive path.
surface. ❑ No
3
I:Building/Forms/PholoV oltai c-Checklist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: REC
Model Number: 260
Listing Agency: UL1703
4
I:/Build ing/Forms/PhotoVoltaic-Checklist.docx
Branden Taggart
From: Branden Taggart
Sent: Wednesday, May 20, 2020 1:21 PM
To: Melissa Farias
Subject: Permit Submittal for 10504 SW Naeve St.
Attachments: Branden Taggart2.vcf;Transmittal Letter_Revisions_052512.pdf; RegPermitAction_
120518.pdf
Hi Melissa,
We received your submittal for the "downsized" solar photovoltaic system for Ann Tran, located at 10504 SW Naeve
Street. However,we will need to receive (1)completed transmittal letter to revise the permit and (1) Request for Permit
Action form for the electrical permit fee refund. Both forms are attached above. Feel free to email this back to me, and
I will route these changes to our Plans Examiner.
Please note that refunds are processed within 4-6 weeks, and the refund will be received in the form of a check. Please
let me know if you have questions.
Thank you,
IN Brendan Taggart
' City of Tigard
R Senior Permit Technician
TU3AkD Community Development
13125 SW Hall Blvd
Tigard, OR 97223
(503)718-2449
brandent@tigard-or.gov
1
RECEIVED
MAY 1 9 2020
Hi City of Tigard O CITY OF TIGARD
BUILDING DIVISION
We originally submitted for this permit as a 7.56 KW, however the customer decided to downsize the
system to a 3kw.
lye attached all new plans/apps just in case it's needed. Feel free to use whats needed to make the
adjustments to the permit, and shred the rest.
Permit: MST20205-00083