Loading...
Plans VALIDITY OF PERMIT THE ISSUANr'E OF A PERMIT Job: Leng BASED DOCUM NTSANDOTH RN 12350 SW Winterview Dr. DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM Tigard, OR 97224 REQUIRING ORs o CORRECTION NW Wanell st. OFFICE COPY LIABILITY The City of Tigard and its employees shall not be responsible for discrepancies which may appear herein. Driveway AC Disconnect next to Utility net meter opposite to 2 story comp roof 22 deg slope main panel inside garage CITY OF TIGARD N REVIEWED FOR ODE COM LIANCE Approved: [ OTC: [ I Permit#: i S W 11 Total roof sq ft: 2,000 W 114A-.4�V� �( Total array sq ft: 365 Address: ,�23�0 S >12"from ridge ratio: 18.25% Suite#: Section 3111 4.81 By: INA Date: /2. ,/'iri2.O (20) REC320NP Solar panels Modules 40"x66" micro inverters under modules Suneye attachmenst every 4' Approved plans or 2' when within 3' or ridge or edge PV array less than 25% roof sq footage shall be on job site. Utility/Net meter Conductors=#10 AWG THHN in 3/4"EMT or FMC Neutral#10AWG PV PV PV PV o Ground #6AWG a 0 Module Module Module Module Distance 40' 00 C \�Qi1 Cutler-Hammer " OO © _ _ S 'v (non tan) 20 Modules with a total of Inverter Black able' 1 10 CP720 Micros split into 2 trunks Red-L2 White-N Trunk cord conductors=#10 Green-G 30A AC Disconnect 200A Modules grounded per ® �, �� �~ 690.43(C)with listed CD Sunmodo rail clips O �� /G � Conductors=#10 AWG THHN 30A *Neutral is a non current carry conductor in 3/4"EMT or FMC used for power line communication only Neutral#10AWG Ground #6AWG Distance 5' Voltage Drop Calculation and wire size all THHN PV Module Ratings copper: Manufacture: REC Inverters trunk cord =.320% Inverter Specs: Model#: REC320NP Manufacture: Chilicon Inverters to AC Disconnect 10 awg =1.032% Open-Circuit Voltage: 40.3V Module: CP720 AC Disconnect to Panel 10 awg =.129% Operation Voltage: 34.2V Max Output Current: 2.4A Total AC Voltage Drop =1.481% Max String Voltage: 1000V Nominal Output Volts: 240V Operating Current: 9.37A Output Frequency: 59.3hZ-60.5hZ AC Point of Interconnection fob: Leng Short-Circuit Current: 10.22A Output Volt Range: 211V-264V (NEC 690.54): Max Series Fuse: 20A Rated AC output: 24A Address: 12350 SW Winterview Dr. Maximum Power(STC): 320W Total number of Modules: 20 (#of invertersX2.4A) Tigard, OR 97224 VOC Temp Coeff: -.27%C System Size: 6.4 kW Nominal AC Voltage: 240V 1V t i o r, I S o i at.r Job: Leng 12350 SW Winterview Dr. ELEVATION Tigard, OR 97224 <18" Section 305.4 PV Module / >_12"from ridge Section 304.8 SPANS EZ roof mount attachment -i 6'6" 1- 2x4 engineered trusses � � Rafter i6'6" r @24" OC 1 e 28' Ext.Wall 22' 20' Spans comply with Table 802.5.1(3) Comp roof, one layer Sunmodo EZ roof mount attachments: UL2703 Compliant L-Foot .(.4,cy— 9/16"hex bolt Rafters @ 24" OC EZ roof mount Attachments 2" Stand off I.II I! @ 48" OC PV Module 4/11: 4"x5/16" lag bolt Aluminum Sunmodo rail Al el1rr oofshoe I�,! I• Micro inverter, 1 per 2 modules Rafter (under Flashing)