Loading...
PFI2020-00213 r CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT 1` COMMUNITY DEVELOPMENT Permit#: PF12020-00213 Date Issued: 06/24/2020 -F f G.A.P D 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Parcel: SEG2260 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: Comcast Project Description: SEG 2260/ 15648 SW Summerfield Lane. Bore one 2" HDPE from dog house through ROW s 9'then bore E under SANS, road ROW to power on house at min. depth of 36". Class of Work: FEES Description Date Amount Type 1 -Utilities(gas, electric,data) PFI Permit Fee 06/24/2020 $300.00 Total $300.00 Owner: REQUIRED INSPECTIONS Call 503-639-4175 for the IVR inspection request line or visit the City of PHONE: Tigard website at www.tioard-or.gov to schedule inspections online. Contractor: LINESCAPE LLC 19100 SW 51ST AVE TAULATIN, OR 97062 PHONE: 5039694409 Applicant: RANDY SHIELDS 11308 SW 68TH PARKWAY TIGARD, OR 97223 PHONE: 5035963996 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: See application Issued By: Special Conditions(See Attached) Note: THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PF12020-00213 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law,the Tigard Municipal Code,and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition,free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEO requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced, with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services Association [ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area.Traffic control devices,flag persons, etc.,shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time,without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept.,Tualatin Fire &Rescue) and to 503-962-8140 (Tri-Met) and 503-431-2345 (Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours (min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m. to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14- UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities (roads, ditches, etc.)as may be necessary, as determined by the Inspector,to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19- PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity,the applicant shall coordinate with the City's inspector, <Insert Name> at<Insert Phone#>,to establish a preconstruction meeting. PFI_Utilities 20- NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms,conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis,to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or -construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general,will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing,of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicants failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance (Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and,also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also,any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER • Applied Notice Other RECEIVED JUN 2 2 202 CIin oftTigard 0 2020-00213 l ` trt'�I l tG '�t. l>l E' ' RI .vII N CITY OFTIGARD NNING/ENGINEERINL Public l'acilities mprovement (Pill) Permit PROJECT INFORMATIt) Pr n mint- 1 a t s i u`M t^r a-Lai . TN PE Of CORK Lr IN Pt. ru■ lS r I$n tieNcttpul =ii pttt}t[i pct. Gt14. P N dPE Y�+YL j •pl t.•ire l� VI\,IS # rw In } tVJ Ana; 6"46 • r .y / fir.., 51L 1t fokyrila TV i I At rai VRIi*A anva•h71.v L o, 14.0 . tiu Aci k' ".�cs.i s 15#o' avi *ns,;n_ Eh o ry t_G►�i • " s .Awarw {Rrar • erne NMn nr4-1 fcvne SITE INFORMATION ' 'Nau re rc•wr• li'iYl aM•aSon•, a•wl man kt»"nip l mean. i ;t xcadahlr : I i st,o itseiOt 11 TtPJ I-ILA k..4,iroweln tt*.% SEG2260Tt ti._oR 9 7axSt jaekath.Yunit twl tow Ia*».Whirr/ innitair.any • 'rdwhr»+.,di*.w"'101l1#ws APPLICANT INFORMAL IONr. • <xr �3w.l,aav; nut �0 relC�� • t.{.Ilnr.."e4 tir.CM a wn' in .M`,t h.Ma F; }i r *�,I Q, j� }�,11 `-" sa,rMi ccoer. Fiend saw. and I*-and 'IA{Itt g addrt% I I?$, . / 7 Y J."* j �• �y r ari[+rn'!tia ( 11''Ralt'; tekMe. 4Ca7 Zip I ?s if [ I1cPEf- inlad1ei actability. ell t' 0 gin Lima 5j t !a ...._ l 7vRf: ..r.:s'as„, "1L::C'�.. . ... Nam 1 and 2 apgietw';e► 1oar he J c^•{{�+ , j �} ( (wain'hr FJ`a1 fc#'rd L, ,,I tti, i,(1PJCt IkUUIC VGA tt Ni I n *C i'va4 CONTRACTOR INI tilt 41It tutu tYl '5 ;2 j.. -� _ t ( N Nuinitrr , I ►" 14a lfsili atltln-ss: 11 Lao.... t4._ 5st vti -,.11 1 , ?., Zit olp a- 1 c ENGINEER INFORMATION Name. N1ading aticireaS; f Phrinr I.tint! ADDITIONAL INFORMATION I. unwtrtl t ahx Ur At/al,.tt"'tjtkttt 4.1 ii r is rt S. ■11.1.$ w"!tfiin dye poker attls' (h tt'I,tic aca#tcj tr,a I.I N 1) I I)I t.hit 1'vr numb, City alTpwd • I t:4 Skt !Lail ii1,I • !"Iyttenl.t Lec K1 ; .'.,'; • walk.tylaedc•s;{xm • ;a,#-1s ZE! • Air I of APPLICANTS NUYL: Prrum yrs-Inni s•Y}lplk+nl"•haZi Ik S..e strd'i,.lmnnef'sini•t,,:l pt••,Mk fala1x1e1 s••utan;t ti W nrvk s requard b•she co,pef.uanl k, PLC 1 i n4 141 taw,dr.1.•}+1r a.a.•vwn.jws••.i,•vwr,••.. wW kc. n rat.Ades Are 001 l yv4 evn+1 n.,Ala.sal/v yV++«+ WV*IlIWI p edA.do ddieam a...It I;.•X{vu•i+•,.a`ny..kl n•dose,a•e•.u,s�+.•1 god odds,. nAok•o. •i tona dM.• tWf i .•its heal 1a 1,4 .4111 .1{•....•n•M•q fM eTroia + ell el,• d. mud 1•„eM.`W.•Minn.e..YNgc a di.naaf li*Irk OA 4wkaln 1:.r1_.,'-<1adw.xv111k11..Ine••lal.nd,,stead d:odd:-,wauar.,e:de t1pL:sxe. I.the apphcam.(chic slur • L..the beat or rise kfrfwla ge,all the rliornnaln pn•.td.d utdun Ida.appliuu.si pwtkai'•n•+afli,iett and daeaftafc. • 'the above request dlrs not creaser am nx,,rdeu cknl n•.1 i sees,d»1 nut-Iry ached to is.unposed kixxi t r •alone prt1lrm. • It thy apytiltew,n is grants.!,I Milt•-tin tv the+ydul.:etanik.I in•re•,nif Ile• with the term%sfal eubjen so all the turlshunw and hnutstkk•a Ili the apper4xl OcAccuno stilt . ppbcant s or sudklturd apnu'..gluturt Pont name I.)utr Pervert)•..axis signatory if tryuirrd Pont•unit [hlt STAFF ItSF:O lei 12Q20:DD21, 2/201 / /1�7a - ` : /2 cire4rived • 1112%FO I IA ht"I • Tapnt et:-n __ • -..•eu:_r1- • r:1-114.24.1 • • DEVELOPMENT ENGINEERINt;FEES rwmic recibir hollow.morn?(PFI)Pamir INITIAL PFt PERMIT FEF Pus Re•fUlttoi ulvnets1 sDr vs 1.1-1 ot 1 VCS I3 ko tolcuiaro klImannon NI-:.r FF1 Plf--RMIT FEE Pot 2: AU a.k•n ennnn Inlet 1."VAN'.1 tktil,:js7C'S lit-in:4X P I lk-ono I-to RATER UNE CONSTItrrilIrN FEE- Pati 11 Pabbc u""' • • ••"Ar 1 CI*11 Alt'Oa.(ANL% 141111 141 Ai 1 I.SE 01121 '111,E&SMALL WI RE4.1,..SS IAaLriy 'JAPE -3;DETAILED St'RMITTAI, IECKLIST REQUIREMENTS 1-1.VI 1 s.1) r. - .gr.ludr rIsri-,h 'truckle facialts*agsdanti. er. • D ' ' 44 6%41 410 Situ, ..11 .;• 1,113110,11111,0111111tioto Nog...mod**ran I?lw. I Or ,r1 14.0:4 to,./tA „14 or 22 r S4,orkl 44,01.111.41,11.11MS1100 at1 oubretatal pomp/sof afropmeku lorouol 41,1sort tio tntosortro, Intnro• "rho phirts 44.4111.14,4111141k; Noirkir Riestwa-ti.7 Poll& la t•Kn ftrypiirossoii tlf tat knits porare ovoory,,to,wit.tin kIrror vow,Cir JAN a OW NItt,""Elan.Pr.rat, ; A.4 a, ,f'OtIlt"4,11 N25111,11 N,HU4 wu, ;1; t4t! tAVICICS,P105.010t44;;S,"14' A Li ?"441,l1 ura4rhutLialStnr: .0 Arr,Ittocri<tCtl'witnikoltk :444 tbnipai imod time not,,rot rend pimp •44, drat 14td•tAil 90.46•14011.„,11 iet,•Cowl-Mr:10,A -.,%;orritt • ,-1.11-.2.4400..:14droorroL • I. so t tssoo. 1,..) 14.-1..is COI of Tigard * 1)125 St).•E•1 • otoo1 /now,II 2." • *kw%tt,garki,o;ow • 4,4'14.;el • Pair J(4'4 aN Ns ... si: r a A . ; • C a kis C • -0 11-T- .... , ) rh") b 1.4 tlo' i.' ' Dgep Ira, / iDovi 4 t i 0 V • 0 ot. p.e..1 14-1"."-. 1`361171" -----,10,. tow. %Fa — ' • 1 15' I 1 I 1 I ' I lift IwC H 1 1 1 I I I He.4 • I I I S..4 11,••••••(I:et.11 LPL I 1 kb 1 . A 0 -1 • s g . •••4 t I' I; If' . 1 I •••C Dew 11101 • 111111111111111110 sew bow OM 17=1=1=2 a=t1Miliellinli )11 1...aw e• sivegiplikt pis./ . . 9 „ • .-., ," Ca gliiiila er irri • Jr g OM . so NIB MIR INN • — ---) T- • /40 Sit' • • 14 A 4.Wag- ....; Page 842011 Edition 2011 Edition Pow.85 S ant' Elena dreiiiiiiirO F ;Fie in 99 9 Diagram 320 Stationary Lane Closure with Flagging Diagram 320 covers total closure of one lane of a two-lane,two-way 99 9 Diagram 320 roadway. See the detail inset for the layout if using a single nagger to control both directions of traffic an low volume roads(less than 400 ADT)with good 4 x sight distance as discussed below. Zt �I 1. Use truck mounted flashing warning fights on work and protection vehicles. See Section 4.3-Lights and Lighted Signs for exceptions. Ok 2. For added visibility,a truck-mounted arrow board or PCMS In caution 8 mode may be used. u $ 4 1cm 3• Flaggers al each approach are required if any of the following ,�g Git conditions exist: a o _ d I F- a. Night Operations. b. Work space is over 200 feel in length. wii c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. t ► •• 4. The length between the Flagger Ahead signs shall not exceed one Q1 g 4 I t •% P mile. Use Diagram 340-Lane Closure with Pilot Car if exceeding one V d 1• mile. 4 1 T. f€ F ., • 5. Cones should be used to outline the work space when curves or other [� - roadway alignments prevent clear direction for the motorists to pass I e 1.-'• �I- the work space safely. j ° v 6. Cones along the work space are recommended when posted speeds E ' Ii are 4s mph orr wer greater,a 11 hen working under heavy traffic or when travel I'. lanes are narrower than 11 feet. _ • 'ilk I 7. Extended queue signing(see Diagram 5-4)should be used when ' a traffic queues extend beyond the initial advance warning sign. c — •�... g 4't ' *I c.N 8. When flagging near an intersection,the"Flagger Ahead'(CW23-2) .r g£ Isign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). s+on ac..mv„a suffer LanesBase 4t inu — u: -_... Posted � Sped"Beiy ear etn yq,s. -�eo _ sw.a: a C Iva pE O 9. Sign set-up and nagger placement shown may be used for intermittent mPN•m.^r n 20 full road closures of 20 minutes or less. zs m « 00 r, xi ,i:o 10. The'ONE LANE ROAD AHEAD"(W20-4)sign is optional and should �" an5 "° "° '� +n °Q be considered on high volume or high speed roads,or when extended W'� ..e�' " +� 9 queues are expected. A0 t00 SS m SI n1 adn, end Suffer ten,tilt feet Su.dement Potted —15pado Between S.nil Buffer 7Mptm5 December 2011 December 2011 Seed A B C Space Chanter$ 60 285 65 700 700 700 325 70 365