Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
2 972 5J ,(c,g wAL.A/4r Sr MSTzozo-ooi 76 PHOTOVOLTAIC ROOF MOUNT SYSTEM RECEIVED E?9ENERGYNTAL 1339 SE 8TH AVE, 42 MODULES-ROOF MOUNTED - 13.44 kWDC, 10.08 kWAC MAY 2 9 2020 eTL 54)3,9/214 Contractor#OR CCB#:195141 12972 SW BLACK WALNUT ST, TIGARD, OR 97224 USA c`r'f '"` TrAAD REVISIONS DIN,; DiViSICN DESCRIPTION DATE REV PROJECT INFORMATION: SYSTEM SUMMARY: . GOVERNING CODES: OWNER: SULAIMAN REZAYEE SYSTEM SIZE : 13.44 KWDC 2017 NATIONAL ELECTRICAL CODE(NEC) ADDRESS: 12972 SW BLACK WALNUT ST,TIGARD,OR 97224 SYSTEM SIZE : 10.08 KWAC OFFICE COPY 2019 OREGON FIRE CODE(OFC) COUNTY: WASHINGTON COUNTY (N)42-HANWHA Q.PEAK DUO BLK-G5 (320W) MODULES 2019 OREGON STRUCTURAL SPECIALTY CODE APN: 2S109DA11300 (N)42-ENPHASE IQ7-60-2-US MICRO-INVERTERS COORDINATES: 45.40802, -122.81038 (N)JUNCTION BOX CUST. PHONE: N/A (E)200A MAIN SERVICE PANEL WITH 200A MAIN BREAKER, PGE ELECTRICAL CONTRACTOR BUILDING DATA: SINGLE FAMILY RESIDENTIAL (N)60A FUSED AC DISCONNECT WITH 60A FUSES, NEMA 3R,240V APPLICABLE CODES: 2017 OESC&2019 OSSC SHEET INDEX MAX, MIN TEMP: 37°,-8° DESIGN CRITERIA: COVER SHEET FINANCING: N/A WIND SPEED:96 MPH(ASCE7-16) PV-1 OVERALL SITE PLAN CLIMATE DATA SOURCE: PORTLAND/HILLSBORO RISK CATEGORY: II PV-2 ROOF PLAN WITH MODULES WIND EXPOSURE CATEGORY: B PV-3 BRANCH LAYOUT GENERAL NOTES: GROUND SNOW LOAD: 25 PV-4 FRAMING PLAN ROOF TYPE:ASPHALT SHINGLE PV-4.1 ATTACHMENT DETAIL 1. PV SYSTEMS AND SUPPORTING STRUCTURE SHALL COMPLY NUMBER OF LAYERS:-01 PV-5 ELECTRICAL LINE DIAGRAM WITH REQUIREMENTSEMSAND F ESC&2019 SSC. ROOF FRAME: PRE-ENGINEERED TRUSSES 24"O.C. PV-6 WARNING LABELS 2. 3111.3.2-PV RACKING AND ATTACHMENTS SHALL BE UL 1703 STORY:TWO ACIDITY OF PERMIT PROJECT NAME CERTIFIED. THE ISSUANCE OF A PERMIT 3. 3111.3.4-PV SYSTEM SHALL HAVE A FIRE CLASSIFICATION BASED ON CONSTRUCTION W THAT IS EQUAL TO OR GREATER THAN THE ROOF ASSEMBLY DOCUMENTS AND OTHER Z REQUIRED BY OSSC SECTION 1505.1. Approved plans DATA SHALL NOT PREVENT W 4. 3111.4.3-3111.4.7-PV LAYOUT SHALL NOT RESTRICT EGRESS, shall be on job S?te. THE CODE OFFICIAL FROM H LIGHT VENTILATION, OR ROOF DRAINAGE REQUIREMENTS. REQUIRING THE CORRECTION - fA 5. 3111.4.8.1 -GENERAL PATHWAY REQUIREMENTS: _ U) • 36"WIDE PATHWAY SHALL NOT BE REQUIRED ON ,-:,, OF ERRORS.ORSC 10' T Z 00 E,.zaCeth STRUCTURES WITH A PV ARRAY AREA OF 1,000 SF OR LESS ' '"cePark "Pe I'm -' _ r INSTALLED ON A ROOF WITH A SLOPE THAT EXCEEDS 2:12 AND PROJECT SITE al ARRAY LOCATION , w J N WITH AN INTERSECTING ADJACENT ROOF AND WHERE NO /ii If1 l CW W j SECTION IS LARGER THAN 150 FEET MEASURED IN LENGTH OR } --- WIDTH. a r� _ ' % �+ rt 0 ••• • WHERE PV ARRAY DOES NOT EXCEED 25%AS MEASURED IN .i �o,d .. i !V PLAN VIEW OF TOTAL ROOF AREA OF A STRUCTURE,A r••.• + LU < O O— } MINIMUM OF 12"UNOBSTRUCTED PATHWAY SHALL BE a, i ~ MAINTAINED ALONG EACH SIDE OF ANY HORIZONTAL RIDGE. +p° ( + J. z m N lcrnq Gay Pu•,.,''- A .,..4Y a• 1C2...�, • WHERE THE SOLAR ARRAY EXCEEDS 25%AS MEASURED IN '; PP t Golf Y. �_J, �` 3 ' PLAN VIEW OF TOTAL ROOF AREA OF THE STRUCTURE,A 412972 e¢ Q "` Brack Walnut Street 1 Green Planet ' \ MINIMUM OF ONE 36"UNOBSTRUCTED PATHWAY SHALL BE ,, t 1 * Will PROVIDED IN ADDITION TO A MINIMUM 12"UNOBSTRUCTED .r. \, > ' 1 Q ti Q i, taa�J*, . ; , •l C)ALONG EA. SIDE OF ANY HORIZONTAL RIDGE. ' i� \ \ i J 6. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED WOOD \ . 1~O 1_„ • i \; 7 Southwest e N CONSTRUCTION WITH PRE-ENGINEERED TRUSSES @ 24"0.C. " ` 1 1T 1 4 REFER TO ALLOWABLE SPAN REQUIREMENTS IN TABLE 305.4.1. sd' w 1 �Iy �Street• 4 • i • `f'a_ 4 -�". - �4,.�.a PROJECT 7. 3111.4.8.5.1 -DISCONNECTS,J-BOXES, COMBINER BOXES OR , GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED PATHWAY CITY OF TIGARD ` �.� • • .+ OR CUTOUT. �•�,�.�`c��77�`�.'`a�a-� yyjj ��. (� N/A J1�.ai Y lli W J.iL' (y�OD•C(r�j.Vrl�LY��i�[]1V CE ; O T..gard ro ...^ A 8. 3111.5.3.1 -TOTAL SYSTEM WEIGHT SHALL NOT EXCEED 4.5 mr.;•:--. 4 v • • • • • SHEET NAME PSF. PV MODULES AND RACKING SHALL BE DIRECTLY Approved: . ATTACHED TO ROOF FRAMING AS SHOWN IN PV-2. OTC: C l Q DMa Treeo a;l ', I A { ' ATTACHMENT SPACING WILL BE 48"O.C. MAX,AND WHEN ' ' 3 i1`A.aaf e 1 i� _ e COVER SHEET ATTACHMENT LOCATED WITHIN 3'OF ROOF EDGE, HIP, EAVE, Permit#: ( ��) — 0D( 1(4 I :4 • I• ' 5 RIDGE SHALL BE 24"O.C. MAX. Y S'' • s� • ' t ' `' ;'4 �` 9. 3111.5.4-MAX MODULE HEIGHT< 18"OFF ROOF SURFACE. Address: 1241-7' . 5 F,1,..d, W41..{401-5i' I +J �� r .— - Sr it4,41?!4'dwsi `dl SHEET SIZE Suite #: I I. ,r, I 4, - ANSI B :t , i ,, ; rat Br: AP►' Date: k 8 �<•, SHEET NUMBER O ';,,COVER SHEET OFFICE COPY CINITY MAP � AERIAL VIEW � - ') SCALE: NTS. SCALE:NTS SCALE:NTS N PU 0 AV �� => Copyright tie,lnr hitnl Energy 2020. AN rights reserved. i PROJECT DESCRIPTION: SW BLACK WALNUT ST ROOF DESCRIPTION EE) ELEMENTAL ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES ROOF TYPE ASPHALT SHINGLE ENERGY 42 HANWHA Q.PEAK DUO BLK-G5(320W) MODULES 1339 SE 8TH AVE, 42 ENPHASE IQ7-60-2-US MICRO-INVERTERS ROOF ROOF TILT AZIMUTH PORTLAND,OR 97214 Phone-(541)316-5786 �5 PROPERTY LINE #1 25° 180° Confractor#ORCCB#195141 SYSTEM SIZE: 13.44 KWDC ---------- 10.08 KWAC #2 25° 270° REVISIONS 1 c I #3 25° 90° DESCRIPTION DATE REV NOTE: *CHECK WITH CITY/COUNTY OR LAND SURVEYOR 1 o EXISTING FOR ACCURATE PROPERTY LOCATION. I ;p DRIVEWAY I 1 N A. 1 CO I-- 1 -4 I t (E)UTILITY METER(EXTERIOR WALL) 1 o V-10.00' ELECTRICAL CONTRACTOR (E) 200A MAIN SERVICE PANEL WITH) L_ 200A MAIN BREAKER(INTERIOR WALL) —� <NN , IZ — Li 1 I (N)60A FUSED AC DISCONNECT WITH 60A FUSES, I H LOCKABLE UTILITY DISCONNECT WITHIN 10'OF METER i I W (EXTERIOR WALL) 1 a_(N)ENPHASE COMBINER PANEL(EXTERIOR WALL) I o s -- ROOF#3 'I I - TILT-25° IY AZIM.-90° ROOF#2 1 O -- 1 a ' TILT-25° I O ❑ --- AZIM.-270° 1 /// -- PROJECT NAME W 0 ROOF#2 i I SUNEYE LOCATION WZ(14)HANWHA Q.PEAK DUO BLK-G5 / 0 H (320W)MODULES I IIII I N— ROOF#3 _ (n (14) HANWHA Q.PEAK DUO BLK-G5 (n ti I 11111111 I I (320W)MODULES L Z N co v I 11'-6" F- W J N .— W I 1 W < 1) ' a_ t i 1 1 I } co Q Y O CD I u? N ROOF#1 ROOF#1 1 U O } (14)HANWHA Q.PEAK DUO BLK-GS TILT-25° Ic7j W Q 0 r- AZIM.-180° J (320W)MODULES I t m ct N I I Q 0Z 1 I I aN ~ Q I I I I J ~ I U) 1 N I I I I I PROJECT I iO 1 N/A I 1 SHEET NAME I I I Z I I OVERALL SITE PLAN I I SHEET SIZE w I ANSI B tL L__ _ ----------- �,OVERALL SITE PLAN 0 1 -__� SHEET NUMBER 1 SCALE: 1/16°= V PROPERTY LINE PU-1 J r �60.00 O Copyright Elemental Energy 2020, Ali rirl'ht: res^+vea. , MODULE TYPE, DIMENSIONS & WEIGHT BILL OF MATERIALS ee ELEMENTAL NUMBER OF MODULES=42 MODULES EQUIPMENT QTY DESCRIPTION ENERGY MODULE TYPE=HANWHA Q.PEAK DUO BLK-G5(320W)MODULES SOLAR PV MODULE 42 HANWHA Q.PEAK DUO BLK-G5 MODULE 1339 SE 8TH AVE, PORTLAND,OR 97214 MODULE WEIGHT=41.23 LBS/18.7 KG. INVERTER 42 ENPHASE IQ7-60-2-US MICRO-INVERTERS Phone-(541)316.5786 MODULE DIMENSIONS= 66.34"X 39.37"= 18.14 SF Contractor#OR CCB#:195141 UNIT WEIGHT OF ARRAY=2.57 PSF ATTACHMENT 108 SUNMODO EZ3 FLASHING REVISIONS RAILS 21 IRONRIDGE XR10 RACKING-168"SECTION GENERAL NOTES: RAIL SPLICE 10 SPLICE KIT DESCRIPTION DATE REV 1. CONDUIT IS DIAGRAMMATIC. FINAL ROUTING TO BE DETERMINED BY INSTALLER. MID CLAMPS 66 MID CLAMPS/UFO 2. SUNEYE SHOT S1 WAS COLLECTED IN THE SPECIFIED LOCATIONS AND CORRESPONDS TO SULAIMAN REZAYEE RESIDENCE SHADE REPORT"PDF SW BLACK WALNUT ST END CLAMPS 36 END CLAMPS I STOPPER SLEEVE GROUNDING LUG 9 IRONRIDGE GROUNDING LUG (E) FRONT OF RESIDENCE ROOF DESCRIPTION ELECTRICAL CONTRACTOR ROOF TYPE ASPHALT SHINGLE (E)UTILITY METER(EXTERIOR WALL) (E) 200A MAIN SERVICE PANEL WITH) ROOF PRE-ENGINEERED PRE-ENGINEERED 200A MAIN BREAKER(INTERIOR WALL) 0 ROOF TILT AZIMUTH TRUSSES SIZE TRUSSESSPACING (N)60A FUSED AC DISCONNECT WITH 60A FUSES, p j� #1 25° 180° 2"X4" 24"O.C. LOCKABLE UTILITY DISCONNECT WITHIN 10'OF METER _ ° in #2 25° 270" 2"X4" 24"O.C. (EXTERIOR WALL) t •— #3 25° 90° 2"X4" 24"O.C. (N)ENPHASE COMBINER PANEL(EXTERIOR WALL) I N ♦ AREA OF NEW AREA OF ROOF TOTAL ROOF AREA PROJECT NAME A• • 59 � (PLAN VIEW)(Sq.Ft.) COVERED BY ARRAY% of / ROOF#2 ROOF#3 U TILT-25° •• I , . _ TILT-25° 762 3171.60 24% Z AZIM. -270` O o AZIM.-90° LLI • 24%ROOF AREA(ARRAY<25%OF ROOF AREA) 0 H • _ • 4 - -- a I x I 0) I- - - D a • _ . N z N O 7. �� wQ � , w 0) < 0- N I (N)IRON RIDGE XR10 RAIL Q (N)(108)SUNMODO EZ3 SPACED AT 24"&48"O.0 LN :71 O > • ROOF#3 0 :,2 J(E)ASPHALT SHINGLE ROOF TYP. y\ °� (E) HANWHA Q.EREDPEAK DUO SEESBLK- @z Q R (320W)MODULES Q 0 z D 5 ° �_ a. ROOF#2 N (E)PRE-ENGINEERED TRUSSES @ 24"O.C. N Q (14)HANWHA Q.PEAK DUO BLK-G5 0 `i ' Q l� (320W)MODULES J r �/D�� N • • • . I • 1 , • C/ T VII* ( .f \ 12"FIRE PATHWAY ///i7 N PROJECT >�6'-8" 26'-10^ 81-2" N/A _ LEGEND SHEET NAME ROOF#1 — ROOF#1 UM UTILITY METER • SUNMODO FLASHING ROOF PLAN WITH TILT-25° (14)HANWHA Q.PEAK DUO BLK-G5 MODULES AZIM.-180° (320W)MODULES MSP 200A MAIN SERVICE PANEL IRON RIDGE XR10 RAIL WITH 200A MAIN BREAKER SHEET SIZE ACC FUSED AC DISCONNECT CHIMNEY ANSI B (E) BACK OF RESIDENCE CB ENPHASE COMBINER PANEL O PIPE VENT ROOFPLAN WITH MODULES A r JB JUNCTION BOX ATTIC VENT SHEET NUMBER SCALE: 3/32" = T-0" CONDUIT RUN PV-2 ©Copyright Elemental Energy 2020.All rights reserved. (42) HANWHA Q.PEAK DUO BLK-G5 (320W) MODULE 12" FIRE PATHWAY ELEMENTAL(42) ENPHASE IQ7-60-2-US MICRO-INVERTERS SWBLACK WALNUT ST b ENERGY • VE. 5785 (3) BRANCHES OF 14 MODULES (E) FRONT OF RESIDENCE 1R3LSN ,ORTH 972 PORTLANq OR 97214 CONNECTED IN PARALLEL PER BRANCH PHOTOVOLTAIC MODULES Phone-(5R CCB :195 HANWHA Q.PEAK DUO Contractor#OR CCe#:195141 ' i BLK-G5(320W) MODULES REVISIONS DESCRIPTION DATE REV �' 66.34" --f J l� ❑ co co ei co ❑ ELECTRICAL CONTRACTOR I1 N. •/ II O 0 1 I PROJECT NAME W E---� jl Z / W ROOF#3 �_ CI (14)HANWHA Q.PEAK DUO BLK-G5 (n 1_ (42)ENPHASE IQ7 60 2 US MICRO INVERTERS IT 1 II (320W)MODULES rn Z O BRANCH#2 I 1 - BRANCH#3 IW Q r CV W II I CT) Q cu ROOF#2 } > (14)HANWHA Q.PEAK DUO BLK-G5 I I N Y O (320W)MODULES . .— Q O >- / W CO I // I pJp fY N J ./ I < PD \ J O \ D N • _--u- -•--. -.Ai--_-a CO N- VJ PROJECT N/A SHEET NAME ROOF#1 (14)HANWHA Q.PEAK DUO BLK-G5 BRANCH LAYOUT (320W)MODULES /BRANCH#1 —' SHEET SIZE ANSI B i �i BRANCH LAYOUT9\r (E) BACK OF RESIDENCE SHEET NUMBER � /� SCALE: 3/32" =1'-0" PV-3 J Copyright Elemental Energy 2020. All rights reser,,,�c1 ee ELEMENTAL 9 (� (E)PRE-ENGINEERED TRUSSES ENERGY - 4 @ 24"O.C. 1339 SE 8TH AVE, EAVE o 0 • PORTL4ND,OR 97214 NN. / ' ` SOLAR MODULES Phone-(541)316-5785 \\// Contractor#OR CCB#:195141 O 1~ REVISIONS () 2 DESCRIPTION DATE REV Q PV4.1 _ ""r- I m ELECTRICAL CONTRACTOR m I m � 'IT co ao y,` I I. 4 N - , N 011 EAVE ICI PROJECT NAME . . -- I w FRAMING PLAN SECTION DETAIL z PV-4 SCALE: 1/8" = 1'-0" w SCALE: 1/16" = 1-0" ❑ (n (E)PRE-ENGINEERED TRUSSES ~ @ 24"O C (E)PRE-ENGINEERED TRUSSES W z Ril- O SOLAR MODULES @ 24"O.C. J (N M LLI •- 5' w - Q 0 \, \ SOLAR MODULES N 0 O O � }waoU) Y mN ' W J Q > 0 z D • Q Q J D CV U) O •• M co M 00 N N PROJECT N/A 0 O N N SHEET NAME j FRAMING PLAN DETAIL SHEET SIZE \ ` • • • ANSI B SECTION DETAIL C6SECTION DETAIL SHEET NUMBER SCALE: 1/8" = 1'-0" V-4 SCALE: 1/8" = 1'-0" PV-4 ©Copyright Elemental Energy 2020. All rights reserved. ea ELEMENTAL �,,. ENERGY - _r/� 1339 SE 8TH AVE, PORTLA_//1 Phone OR6-5788 �% 97214 Phone-(541)3165786 ,. ����/�� Contract REVISIONS 195141 PV MODULE "1 DESCRIPTION DATE REV SEE(2/PV-4.1) FOR ATTACHMENT DETAIL (ENLARGED VIEW) d i�d ELECTRICAL CONTRACTOR \-- (E)ASPHALT SHINGLE ROOF ilik ���� ``�riP \ PRE-ENGINEERED TRUSSES @ 24" O.C. O"" `�O PROJECT NAME w ATTACHMENT DETAIL U z SCALE: NTS. LU C f- PV MODULE inJ N o W Q END/MID CLAMP } CD IRONRIDGE XR10 RAIL U O o L-FOOT SERRATED W Q - .- 1_ CD C N J Q s 0 Z D (E) ASPHALT SHINGLE ROOF N ~ Q J 0) �'IfiPJ°#0 40 *ti1" _ ' D N -04- 1\0. �� PROJECT AirliSUN MODO EZ3 FLASHING NIA SHEET NAME Ailler Ai PRE-ENGINEERED TRUSSES @ 24" O.C. ATTACHMENT 41 DETAIL 5/16" X3" LAG BOLT SHEET SIZEANSI B ` ATTACHMENT DETAIL (ENLARGED VIEW) SHEET NUMBER 2 SCALE: NTS. PV-4.1 CO Copyright Elemental Energy 2020. All rights reserved. CONDUCTOR SCHEDULE AND CALCULATIONS ea ELEMENTAL ~TAG LOCATION DESCRIPTION EQUIPMENT #OF STRING CURRENT(A) STC #PARALLAL #C.CARRYING WIRE WIRE COND. COND. MULTI MULTI DERATED 1-WAY VD VD OCPD NEUTRAL GROUND CONDUIT CONDUIT ENERGY WIRE RUN FROM HOME RUN ID STRING IMP ISC 690.9(13)(5) VOLTAGE(V) RUNS CONDUCTORS SIZE TYPE MATERIAL RATING(A) TEMP #COND. (A) L(FT.) VOLTS % RATING SIZE SIZE TYPE SIZE 1339 SE 8TH AVE, AC1 PV STRING TO JUNCTION BOX STR 3 9.47 9.94 17.50 240 1 2 12 AWG THWN-2 CU 30 0.91 1.0 27.30 55 3.06 1.27% N/A N/A 6 AWG FREE AIR N/A PORTLAND.OR 97214 AC2 JUNCTION BOX TO COMBINER BOX J BOX 3 9.47 9.94 17.50 240 1 2 10 AWG THWN-2 CU 40 0.71 1.0 28.40 30 1.05 0.44% N/A N/A 10 AWG EMT 3/4" Phone-(541)316-57 86 Contractor#OR CCB#:195141 AC3 COMBINER BOX,ACD TO COMNINER BOX N/A - - 52.50 240 1 2 6 AWG THWN-2 CU 75 0.91 1 68.25 10 0.41 0.17% 52.50 6 AWG 8 AWG EMT 3/4" INTERCONNECTION REVISIONS MAX VOLTAGE DROP: 1.88% DESCRIPTION DATE REV ELECTRICAL CONTRACTOR BI-DIRECTIONAL UTILITY METER 1-PHASE,3-W, 120V/240V 14 MICRO-INVERTERS IN BRANCH CIRCUIT#1 TO UTILITY GRID L1 L2 N / LOCKABLE UTILITY DISCONNECT _ . . . WITHIN 10'OF METER (N)125A ENPHASE 0 UTILITY METER COMBINER PANEL (EXTERIOR) tEEI-/ I / I i NEMA-3R,120/240V,1$ SUPPLY SIDE PROJECT NAME / • ) • ) (EXTERIOR) INTERCONNECTION W m ❑ ❑ ❑ U (E)MAIN BREAKER, Z 14 MICRO-INVERTERS IN BRANCH CIRCUIT#2 200A RATED,120/240V WI - (INTERIOR) . (E)MAIN SERVICE Q I- 15A 60A FUSED AC • PANEL,200A RATED, - Cl) (N)JUNCTION BOX " 120/240V(INTERIOR) Cr) I- • DISCONNECT WITH 60A 20A FUSES,LOCKABLE 200A o(o LLI D CD (l- 1- i &813-7 i �l / i , L4 UTILITY DISCONNECT ` ` Z (V CO ,V I 4, ti I WITHIN 10'OF METER, o W J (V LLI �) J"�) '�") L--- 20A NEMA 3R,240V o LLI Q ti .- 0 m t5 ❑ ❑ i (N)JUNCTIONBOX _T •20A (EXTERIOR) o N Y 0Cr) O rGi _ L 14 MICRO-INVERTERS IN BRANCH CIRCUIT#3 i ^BOA FUSES/ ^ W 0 O _ -I L, n v-d o et a Q (n . . . L2 " Z CO Et N (N)JUNCTION BOX - Q N N Q _U Z It 17 _ G ® IQ-Envoy - G CC ,^ Al /N i i V I Q Q �.) J�-./ / — - z6==='==ii F. 1 I GEC N @ ❑ ❑ ❑ L �I I T----J --- ` AC3 __ (n N- (2)6 AWG THWN-2 GROUNDING - ENPHASE IQ7-60-2-US MICRO-INVERTERS(240V) AC1 AC2 (1)6 AWG THWN-2 NEUTRAL ELECTRODE SYSTEM (LOCATED UNDER EACH PANEL) (1)Q-CABLE (2)10 AWG THWN-2 (1)BAWG THWN-2 GND PROJECT (2)12 AWG TRUNK CABLE (1)10 AWG THWN-2 GND IN 3/4"EMT CONDUIT BRANCH TERMINATOR Q-TERM (1)PV 6 BARE CU GND IN 3/4"EMT OR NMB ROMEX N/A FOR IQ SERIES(TYP.) SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE GENERAL NOTES: ANSI B E::i:iiEi)ELECTRICAL LINE DIAGRAM 1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL SHEET NUMBER LOCAL OR NATIONAL CODE REQUIREMENTS AND EQUIPMENT INSTALLATION INSTRUCTIONS. PV-5 SCALE: NTS 2. SEE PV-6 FOR LABELING REQUIREMENTS ©Copyright Elemental Energy 2020. All rights reserved. 2" ELEMENTAL '1' 2" )r ; ,� 4" ,� Ems? ENERGY - WARNING: -- - -- - ♦ 1339 SE 8TH AVE, ELECTRIC SHOCK HAZARD. PORTLAND,OR 97214 TERMINALS ON THE LINE SOLAR AC DISCONNECT WARNING:DUAL POWER SOURCES PRESENT. Phone Contractor*ORICCB#:195141 AND LOAD SIDES MAY BE 240VAC 42 AAC - 13440 WATT PHOTOVOLTAIC ARRAY LOCATED ON ROOF. _ ENERGIZED IN THE OPEN AC DISCONNECT AND RAPID SHUTDOWN INITIATION DEVICE REVISIONS POSITION. 1 LOCATED OUTSIDE NEXT TO THIS METER. DESCRvnoN DATE REV ♦ LOCATION: AC DISCONNECT, QUANTITY:1 • LOCATION:AC DISCONNECT QUANTITY:1 LOCATION:AT METER QUANTITY:1 DC DISCONNECT 690.17E 3" _- � ♦ SOLAR PV SYSTEM ,Y ' ELECTRICAL CONTRACTOR TWO POWER SOURCES PRESENT.SECOND SOURCE IS A PV ARRAY.SUPPLY SIDE X 1 1/2" Jr ♦ EQUIPPED WITH CONNECTION IN THIS PANEL.AC DISCONNECT :- AND RAPID SHUTDOWN INITIATION DEVICE BRANCH#1 DISCONNECT N RAPID SHUTDOWN LOCATED OUTSIDE LOCATED NEXT TO METER. 240VAC 14 AAC LOCATION: INTERCONNECTION PANEL QUANTITY:1 LOCATION: COMBINER PANEL QUANTITY:1 1 1/2" ), .r ♦ I PROJECT NAME 5.25" BRANCH#2 DISCONNECT N 011.1 240VAC 14 AAC \ \ Lo❑ Z LOCATION: COMBINER PANEL QUANTITY:1 , 1U - RAPID SHUTDOWN SWITCH LLI D o Co X 1 v2 X_slcTURN RAPID SHUTDOWN ' cc w J N o w FOR SOLAR PV SYSTEM BRANCH#3 DISCONNECT & 1 I " in < ~ ,_ CD 240VAC14AAC SWITCH TO THE OF "F rn Q a. POSITION TO SHUT N o o ii LOCATION: COMBINER PANEL QUANTITY:1 H \ DOWN PV SYSTEM AND CC < a in -H m CC N J LOCATION: RSD INITIATION DEVICE QUANTITY:1 REDUCE SHOCK HAZARD Q > < Z I 2" IN THE ARRAY Q p a s N T Cn CAUTION: 3 4' PHOTOVOLTAIC SYSTEM _ COMBINER PANEL.DO PROJECT NOT ADD LOADS. LOCATION: MAIN DISCONNECT QUANTITY:1 N/A ♦ SHEET NAME LOCATION: COMBINER PANEL QUANTITY:1 WARNING LABELS SHEET SIZE ANSI B SHEET NUMBER PV-6 i i!jht Flon ntal Fnergy 2020_ Ail rights re:terwA,