Plans
• OREGON STATE CODE COMPLIANCE: ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WIT-' T ■ • 0 ■ THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES.NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO PERMIT OFF-ICE COPY E,, WORK NOT CONFORMING TO THESE CODES: • CITY }''! 'Ti(� A n 2019 OREGON STRUCTURAL SPECIALTY CODE TT T� CIT 1' OF TIGARD 2017 OREGON MECHANICAL SPECIALTY CODE R�VlE,V �'� r'U ( i,v llli COMPLIANCE SITE NAME: SITE NUMBER: IV 201]OREGON RESIDENTIAL SPECIALTY CODE T M 2019 OREGON FIRE GOOE 2012 O REGON ZERO ENERGY READY COMMERCIAL CODE 2017ENERGYEGONCONSERVATION CODE SPECIALTY OREGON Approved: I WA SQUARE MALL POYHO24A APR 2017 OREGON ELECTRICAL CODEE 2020 2010 OREGON PLUMBINGSPECIALTYDWELLING 0 / 2002 OREGON MANUFACTURED INSTALLATION SPECIALTY CODE �`�� r Cl OF 11� " I LOCAL ODE MANAMENREDDWELLINGANDPARKSPECIALTVCODE • POYHO24A WA SQUARE MALL DAS FCD TAEC 01 -29-2018 LOCAL CODES AND AMENDMENTS . .Jyyy f.f ' + r-'•2,-)P- ITC Tlill tt: �f•2•�^�� 1Q- — — LI 7•-,1,0 F12n 290 02Puce SS REV FCC NOTE: l �Yf• 4 a, roaLTeNt115 D' MEM'. THIS WIRELESS COMMUNICATION FACILITY COMPLIES WITH FEDERAL STANDARDS FOR Address: 9vc-�?s �...at 9 W WASHINGTON SQ. RD., PORTLAND, OR 97216 • • RADIO FREQUENCY IN ACCORDANCE WITH THE TELECOMMUNICATION ACT OF 1996 AND ` . T f SUBSEQUENT AMENDMENTS AND ANY OTHER REQUIREMENTS IMPOSED BY STATE OR S1 i t e #: C O _-- y ■■Mobiles• FEDERAL REGULATORY AGENCIES. x J(I JI 1 C�C�� CODE COMPLIANCE t 1. Date: `rJI 8961)ALDERWOODROAD -'L _ PORTLAND,OR 97220 APPLICANT: _�+`-VA TWOBILE USA INC. 830 NE HOLLADAY STREET Technology Associates PORTLAND,OR 97232 PROPERTY OWNER: PNW MARKET OFFICE 9364 SW WASHINGTON SQUARE RD ® el. • y �1"�ti 'r:. 711TSW BEVELAND STREET, TOTAL LEASE AREA: Reai4 --01)Centert) MN! 'V-.� ; SHEET DESCRIPTION SUITE 101 TIGARD.OR 9rn5 :n:_ • ` TIGARD.• OR 98006 2 30 eQ.X. 1 T iR �, 14 a. h. . -= • f E- TA TITLE SHEET • SITE ADDRESS: EXISTING USE , •a-�.-„ , - N 1 =�•I T-2 NOTES&LEGEND 9585 SW WASHINGTON SO.RD. UNMANNED TELECOMMUNICATIONS FACILITY Technology Associates PORTLAND.OR 97zw 8 � y I �- • ; ;+ A-1 SITE PLAN SITE PARCEL NUMBER: NEW USE: ., t5 ARCHITECTURE&ENGINEERING 151280000300 UNMANNED TELECOMMUNICATIONS FACILITY y 4 Ill `1.7:� A-2 FIRST FLOOR PLAN '.W „Fh +-+ •• .4� + 2851 GAMING DEL RIO SOUTH,STE.200 ® ••a"• , "Tl) SAN DIEGO,CA 92108 COUNTY: JURISDICTION: 1 S `'eil •yA3 EQUIPMENT PLANSMULTNOMPH COUNTY CITY OF TGARO SITE . �,-+;- A-4 DETAILS LATITUDE AND LONGITUDE: ZONING: ' /� L - �. ` t E-1 ELECTRICAL NOTES - N 45.451194W',W 122]7922600' IM _ f`•� _ • Q' - ', a1NwaOlS PTG GOMMEN%S MUM (BASED ON RFDS V.0.1 DATED:07/12/2017) - I *.-� :�'i E-2 ELECTRICAL SITE PLAN a 5/1/10510 IFVSE5ESNEETB EL LEGAL DESCRIPTION: se ' 1 R J • -•- E-3 GROUNDING DIAGRAM AND NOTES 09rz2I2017 NEW rs DIAGRAM MGM PER ASSESSOR FILE: (-) - ( rr yy - . - O �t p:1: l it i -Ai arP .} 0-1 R9"NI2 ISSUED FOR I[MUD RENEW MGM HANDICAP REQUIREMENTS 6 �_: e _n-• GROUNDING PLANS • ` ' A W,OIg011 ISSUED FOR 90%CD RENEW MGM FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.HANDICAP ACCESS REDUIREMENT(5) A '"'�• u. 1" 4;ea G-2 GROUNDING DETAILS REV DATE DESCRIPTION By DONOTAPPLV t • •6A1IN i-'T _ e T ' , ,,,f D-2 REMOTE NODE WIRING DIAGRAM SITE INFORMATION .. POYHO24A _- ordt-. 9 5 _NSTALL(5)NEW FV6B(1 PER EACH NODE) V . WA SQUARE NSTALL(5)NEW FWFA(1 PER EACH NODE) NSTALL(6)NEW FOFA(1 PER EACH NODE) .��. 1 ♦ • �•+ t yaa 1• I NSTALL(1)NEW1D-RACK ®- • , - t 4�1. I ` MALL N NSTALL CO NEW CSR ROUTER INSIDE EXISTING SERVER ROOM - W,161 Y" uNSTALL(t)NEW AAV BACKHAUL ROUTER _ - 5 NSTALL(t)NEW 5AR-6RO ER or 11 scn:r `* 9585 SW WASHINGTON SQ.RD. NSTALL(3)NEW SAR-A ROUTER • + '- +• + W NSTALL(1)NEW OURACOM AC.DC POWER CONVERTER NSUTERSINEWH6ER CABLE FROM EXISTING TELCO ROOM(HOER DEMARC)TO NEW UA10B1LE VICINITY MAP LOCAL MAP p RSTALL(INEWFIBE CABLE PORTLAND, OR 9721 w POWER TO BE PROVIDED BY LANDLORD FROM EXISTING ELECTRICAL ROOM(EXISTING PANEL 2A 120/240V,30.4W,200A - IN-BUILDING PROJECT DESCRIPTION o STARTING FROM 9900 ALDERWOOD ROAD PORTLAND OR 97220- APPROVAL SIGNATURE DATE 1. HEAD SOUTHEAST ON NE ALDERWOOD RO TOWARD ALDERWOOD TRAIL PROJECT MANAGER SHEET INDEX o PROJECT MANAGEMENT: ZONING&PERMITTING: 2. TURN RIGHT ONTO NE 105TH AVE T-MOBILE USA INC. TECHNOLOGY ASSOCIATES EC,INC 3. TURN RIGHT ONTO NE SANDY BLVD T-MOBILE RF ENGINEER 830 NE HOLLADAY STREET 7117 SW BEVELAND STREET SUITE 101 4. TURN LEFT ONTO NE 102ND AVE DO NOT SCALE DRAWINGS PORTLAND,OR 91232 TIGARD.OR 27223 SITE AGOUISITON 11C CONTACT: NEELY WILLIAMS CONTACT: HANNAH KAMPH 5. TURN RIGHT TO MERGE ONT01-84 WNS-30 W TOWARD PORTLAND w OFFICE: (406)546-8073 OFFICE, (509)4224905 6. MERGE ONTO I-84 WNS90 W EMAIL: ke61y.WXliema310@4moblle.wm EMAIL: h L hannaamh� «pb .nel CONSTRUCTION MANAGE • R Li ]. USE THE LEFT 2 LANES TO TAKE THE EXIT TOWARD SALEM CONTRACTOR SHALL VERIFY ALL PLANS&EXISTING LOCATIONS, 8. MERGE ONTO 13 S CONDITIONS ON THE JOB SITE&SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING • SITE ACQUISITION: CONSTRUCTION MANAGER: SITE OWNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE 9. KEEP RIGHT AT THE FORK TO STAY ON-5 5,FOLLOW SIGNS FOR JURISDICTION APPROVAL SCAMP • TECHNOLOGY ASSOCIATES EC,INC TECHNOLOGY ASSOCIATES EL.INC FOR SAME i 7117 SW ORBEVELAND STREET SUITE 101 7117 SW OR 0722ND STREET SUITE 101 INTERSTATE 6 S15ALR T-MOBILE DEVELOPMENT • DEVMIIMENT FOR LAW USE » TIGARD,OR 97223 TIGARD,OR 27223 10. TAKE EXIT 206 TOWARD CAPITOL HIGHWAY MANAGER DEPARTMENT FOR BUILONO 6 CONSTRUCTION CONTACT: HANNAH KAMPH CONTACT: JEREMY JONES n 11. TURN LEFT ONTO SW TAYLORS FERRY RD T-MOBILE CONSTRUCTION OFFICE: (503)422-2265 PHONE: (503)949-0759 EMAIL: hamah Nampheataee am EMAIL'. jeremyones�M«.nat 12. TURN RIGHT ONTO SW 80TH AVE MANAGER SHEET TITLE I 19. TURN LEFT ONTO SWOLESONRD TITLE I T-MOBILE OPS MANAGER o ARCHITECTURE: ENGINEER: ER. CONTINUE ONTO SW GREENBURG RD (qv __ FIC Know what's below. TECHNOLOGY ASSOCIATES EC,INC TECHNOLOGY ASSOCIATES EC.INC 16. TURN RIGHT ONTO SW WASHINGTON SQUARE RD T-MOBILE REGULATORY REVIEW CALL before you dig. SHEET n 7808 SOUTH HIGHLAND DRIVE,STE.200 7826 SOUTH HIGHLAND DRIVE.STE.200 16. TURN RIGHT COTTONWOOD HEIGHTS,UT 84121 COTTONWOOD HEIGHTS.LIT 84121 ,. .:0„,7 a T-MOBILE PROJECT MANAGER T 1. = CONTACT'. JOEL R.HARTMAN,PE CONTACT: JOEL R.HARTMAN,PE 1T. TURN LEFT OFFICE: (eDp 463-tO2(16210) OFFICE: (801)969-1020A 210] th D L_ SHEET NUMBER EMUI: OM grtmen®a«nat EMAIL: joeLha,tman®te«.net CALL AT LEAST TWO WORKING T-MOBILE PERMITTING € DIG ALERT DAYS BEFORE YOU DIG T. 01 CONTACT INFORMATION DRIVING DIRECTIONS APPROVALS D GENERAL NOTES 1. THIS FACILITY IS EXEMPT FROM HANDICAP REQUIREMENTS PER 201A OREGON STRUCTURAL SPECIALTY CODE SECTION 110329.THIS FACILITY IS NON OCCUPIABLE SPACE AND ENTERED ONLY BY SERVICE PERSONNEL.THIS SPACER NOT FOR HUMAN OCCUPANCY. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING HIS BID.ANY DISCREPANCIES. ABBREVIATION DEFINITION ABBREVIATION DEFINITION ABBREVIATION DEFINITION CONFLICTS OR OMISSIONS SHALL BE REPORTED TO THE ENGINEER PRIOR TO SUBMITTING BIDS.AND PROCEEDING WITH ANY WORK. - 3. THE CONTRACTOR SHALL NOTIFY ENGINEER OF ANY ERRORS,OMISSIONS,OR DISCREPANCIES AS THEY MAY BE DISCOVERED IN THE PLANS, AB ANCHOR BOLT FAB. FABRICATION(OR) EWE POWER(CABINET) SPECIFICATIONS.6 NOTES PRIOR TO STARTING CONSTRUCTION.INCLUDING BUT NOT LIMITED BY DEMOLITION.THE CONTRACTOR SHALL BE ABV. ABOVE F.F. FINISH FLOOR CITY. QUANTITY RESPONSIBLE FOR CORRECTING ANY ERRORS,OMISSION,OR INCONSISTENCY AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN ACCA ANTENNA CABLE COVER ASSEMBLY F.G. FINISH GRADE RAD.IR) RADIUS BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER AND SHALL INCUR ANY EXPENSES TO RECTIFY THE SITUATION.THE METHOD OF ADD'L ADDITIONAL FIN. FINISH(ED) REF. REFERENCE CORRECTION SHALL BE APPROVED BY THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT. A.F.F. ABOVE FINISHED FLOOR FLR. FLOOR REINF. REINFORCEMENT(ING) ED A. PRIOR TO STARTING CONSTTJGTION,THE CONTRACTOR HAS THE RESPONSIBILITY TO LOCATE ALL EXISTING UTILITIES.WHETHER OR NOT AF.M. ABOVELIFINISHED GRADE FOAL. FOUNDATIONFROE REQDIG SHOWN ON THE PLANS,ABS TO PROTECT THEM FROM DAMAGE.THE CONTRACTOR OR SUBCONTRACTOR SHALL BEAR THE EXPENSE OF ALTAR. ALUMINUM F.O.C. FACE OF CONCRETEYROE. RIGIDGALVANIZED REMOTETTEEL REPAIRING OR REPLACING ANY DAMAGE TO THE UTILITIES CAUSED DURING THE EXECUTION OF THE WORK.CONTACT USA DIG ALERT M ALT.T ALTERNATE F.O.M. FACE OF MASONRY RRU. RADIOE EUNIT ANT. ANTENNA F.O.S, FACE OF STUDWALL SOH. SCHEDULE 800-22)'N00 ARCH. ARPIIITECAUR.NL) F.O.W. FACE OFWALL SHT. SHEET 5. PRIOR TO STARTING CONSTRUCTION,THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING ARCH. ARCHITECT(URAL) F.S FINISH SURFACE SIM. SIMILAR CONSTRUCTION.ANY DAMAGE TO PROPOSED OR EXISTING SURFACES.STRUCTURES OR EQUIPMENT SHALL BE IMMEDIATELY REPAIRED OR AWO. AMERICAN WIRE GAUGE FT.() FOOT(FEET) SPEC. SPECIFICATION(S) REPLACED TO THE SATISFACTION OF THE PROPERTY OWNER.THE CONTRACTOR SHALL BEAR THE EXPENSE OF REPAIRING OR REPLACING BLDG. BUILDING Fr . FOOTING SQ. SQUARE ANY DAMAGED AREAS. BLK. BLOCK G. GROWTH(CABINET) S.S. STAINLESS STEEL BLKG. BLOCKING GA. GAUGE STD. STANDARD 8. A COPY OF THE APPROVED PLANS SHALL BE KEPT IN A PLACE SPECIFIED BY THE GOVERNING AGENCY,AND BY LAW SHALL BE AVAILABLE FOR BM. BEAM GI. GALVANIZE(D) STL. STEEL INSPECTION AT ALL TIMES_IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE ALL CONSTRUCTION SETS REFLECT THE SAME B.N. BOUNDARY NAILING G.F.I. GROUND FAULT CIRCUIT INTERRUPTER STRUC. STRUCTURAL IT G AVIOIATIN OF LAW FOR ANY PERSON.OLESS THEE INFORMATION AS THE APPROVED PLANS THE CONTRACTOR SHALL ALSO MAINTAIN ONE SET OF PLANS AT THE SITE FOR THE PURPOSE OF STOW. BARE TINNED COPPER WIRE GLB.(OLU{AM) GLUE LAMINATED BEAM TEMP. TEMPORARY ARE ACTING NITER IRE DIRECTION OF A LICENSED DOCUMENTING ALL AS-BUILT CHANGES.REVISIONS.ADDENDA.OR CHANGE ORDERS.THE CONTRACTOR SHALL FORWARD THE B.O.F. BOTTOM OF FOOTING CAPS GLOBAL POSITIONING SYSTEM THIS. THICK(NESS) PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT. AS-UILTMIRED DRAWINGS TO THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT AT THE CONCLUSION OF THE PROJECT. BN BACKUP CABINET GRIND. GROUND TMA TOWER MOUNTED AMPLIFIER CAB. CABINET HOE HEADER T.N. TOENAIL 7 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE THE WORT IS IN PROGRESS UNTIL THE JOB IS CANT. CANTILEVERED) NOR. HANGER T.O.A. TOP OF ANTENNA COMPLETE COP. CAST IN PLACE HT. HEIGHT T.O.C. TOP OF CURB //��• CLG. CEILING ICGB. ISOLATED COPPER GROUND BUS T.O.F. TOP OF FOUNDATION ■ •■■■ O 1 P■ B. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE TEMPORARY POWER.WATER,AND TOILET FACILITIES AS REQUIRED BY THE PROPERTY CLR. CLEAR IN.(') INCH(ES) TO.P. TOP OF PLATE(PARAPET) 1 v OWNER OR GOVERNING AGENCY. COL. COLUMN INYY. INTERIOR T.O.S. TOP OF STEEL CONC. CONCRETE LE.(0) POUND(S) T.O.W. TOP OF WALL B, ALL CONSTRUCTION THROUGH THE PROJECT SHALL CONFORM TO THE LATEST OREGON BUILDING CODES AND ALL OTHER GOVERNING CONN. CONNECTION(OR) L.B. LAG BOLTS TYP, TYPICAL 8960 ALDERWOOD ROAD CODES,THE MOST RESTRICTIVE CODE SHALL GOVERN. CONST. CONSTRUCTION L.F. LINEAR FEET(FOOT) U.G. UNDER GROUND PORTLAND,OR 97220 CONT. CONTINUOUS L. LONG(ITUDINAL) U.L. UNDERWRITERS LABORATORY 10. THE CONTRACTOR AND SUBCONTRACTOR SHALL COMPLY WITH ALL LOCAL AND STATE REGULATIONS INCLUDING ALL OSHA REQUIREMENTS. S PENNY(NAILS) MAS. MASONRY U.N.O. UNLESS NOTED OTHERWISE DBL. DOUBLE MARL MAXIMUM V.I.F. VERIFY IN FIELD II. WHEN REQUIRED STORAGE OF MATERIALS OCCURS,THEY SHALL BE EVENLY DISTRIBUTED OVER THE FLOOR OR ROOF SO AS NOT TO DEPT. DEPARTMENT M.B. MACHINE BOLT W WIDE(WIDTH) EXCEED THE DESIGNED LIVE LOADS FOR THE STRUCTURE TEMPORARY SHORING OR BRACING SHALL BE PROVIDED WHERE THE STRUCTURE D.F. DOUGLAS FIR MECH. MECHANICAL W/ WITH TechnologyAssociates OR SOL HAS NOT ATTAINED THE DESIGN STRENGTH FOR THE CONDITIONS PRESENT DIA DIAMETER MFR. MANUFACTURER WD. WOOD U. THE CONTRACTOR SHALL SUPERVISE AND COORDINATE ALL WORK,USING HIS PROFESSIONAL KNOWLEDGE AND SKILLS.HE IS SOLELY DIAL. DIMENSIONDIAGONAL MIN. MINIMUM W.P. WEATHERPROOF RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METHODS.TECHNIQUES.PROCEDURES AVE SEQUENCING AND COORDINATING ALL DIM. UTL. MISCELLANEOUS WT. WEIGHT PORTIONS OF THE WORK UNDER THE PROJECT. DWG. DRAWING(S) MTL. METAL F CENTERLNE OWL. DOWELIS)EACH I+"a.(I� NUMBER B PLATE PNW MARKET OFFICE 13. THE CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN AND PAY FOR ALL PERMITS LICENSES AND INSPECTIONS WITH RESPECT TO THE 7117SW BEVELAND STREET, WINK TO COMPLETE THE PROJECT.BUILDING PERMIT APPLICATIONS SHALL BE EXEC BY THE OWNER OR AUTHORIZED AGENT.CONTRACTOR EL. ELEVATION N.TS. NOT TO SCALE SUITE 101 SHALL OBTAIN THE PERMIT AND MAKE FINAL PAYMENT OF SAID DOCUMENT. ELEC. ELECTRICAL OC ON CENTER TIGARD,OR98006 ELEV. ELEVATOR OPNG. OPENING 14 ALL DIMENSIONS TAKE PRECEDENCE OVER SCALE.DRAWINGS ARE NOT TO BE SCALED UNDER ANY CIRCUMSTANCES. ENT ELECTRICAL METALLIC TUBING P/C PRECAST CONCRETE E.N. EDGE NAIL PCS PERSONAL COMMUNICATION SERVICES 15. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING,BACKING,FRMIING,HANGERS OR SUPPORTS FOR INSTALLATION OF ITEMS ENG. ENGINEER PLY. PLYWOOD INDICATED ON THE DRAWINGS. EC/ EQUAL PPG POWER PROTECTION CABINET Technology Associates EXP. EXPANSION PRC PRIMARY RADIO CABINET 18. THE CONTRACTOR SHALL PROVIDE THE FIRE MARSHALL OR ILL APPROVED MATERIALS TO FILL/SEAL PENETRATIONS THROUGH FIRE RATED EXST.(E) EXISTING P.S.F. POUNDS PER SQUARE FOOT ASSEMBLIES. EXT. EXTERIOR P.S.I. POUNDS PER SQUARE INCH PT. PRESSURE TREATED ARCHITECTURE&ENGINEERING IT. PROPOSED CONSTRUCTION ADDED TO EXISTING CONSTRUCTION SHALL BE MATCHED IN FORM,TEXTURE.MATERIAL AND PAINT COLOR EXCEPT AS NOTED IN THE PLANS. 2851 CAMINO DEL RIO SOUTH, SAN DIEGO,CA 92108 IA, THE CONTRACTOR IS TO PROVIDE PORTABLE FIRE EXTINGUISHERS HAVING A MINIMUM 2A:10-BC RATING WITHIN T5FT.OF TRAVEL TO ALL PORTIORE O THE RE CODESCTION0081. ABBREVIATIONS 1 P TONS OF FIEFO CODE SECTION REA, 6BOB.1.7 AND SECTION 908.3.11 IS_. MATERIALS TESTING SHALL BE TO THE LATEST STANDARDS AVAILABLE AS REQUIRED BY THE LOCAL GOVERNING AGENCY RESPONSIBLE FOR APPROVING THE RESULTS. ofnarrufe ATC COMMENTS MGM 20. ALL GENERAL NOTES AND STANDARD DETAILS ARE THE MINIMUM REQUIREMENTS TO BE USED IN CONDITIONS WHICH ARE NOT SPECIFICALLY Q NEW ANTENNA OX GRID REFERENCE 2 01n02018 REVISED ESNEETs EL SHOWN OTHERWISE. ® DETAIL REFERENCE 1 WR2a01T NEW RF DIAGRAM MGM 21. ALL IJEPRE AND REFUSE IS TORE REMOVED FROM THE PROJECT.PREMISES SHALL BE LEFT INACLEAN BROOM FINISHED CONDITION AT ALL EXISTING ANTENNA ® 0 CR57DT7 ISSUED I OH 1006Ln RE VIEW MGM TIMES. 22. BUILDING INSPECTORS AND/OR OTHER BUILDING OFFICIALS ARE TO BE NOTIFIED PRIOR TO ANY GRADING AND CONSTRUCTION EFFORT AS ® ELEVATION REFERENCE A OMl1aBU ISSUED FOR m%cD PEVEYI MGM MANDATED BY THE GOVERNING AGENCY. GROUND ROD REV DATE DESCRIPTION BY 23. ALL SYMBOLS AND ABBREVIATIONS ARE CONSIDERED CONSTRUCTION INDUSTRY STANDARDS.IF A CONTRACTOR HAS A QUESTION -1-6/ _ I SECTION REFERENCE REGARDING THEIR EXACT MEANING THE ARCHITECT OR THE ENGINEER RESPONSIBLE OF THE PROJECT SHALL BE NOTIFIED FOR GROUND BUS BAR �/ CLAW FICTIONS 24. SITE CONTRACTOR TO CALL DIG ALERT(1-800)227-2690)TO LOCATE ANY AND ALL UNDERGROUND UTILITIES PRIOR TO ANY EXCAVATION. R GRWTORPLASTER POYHO24A • MECHANICAL GRNO.CONN. W 25. ALL FACILITIES TO BE INSTALLED ARE UNMANNED.NO(E)PARKING SPACES WILL BE USED OR REMOVED BY THIS PROJECT. I (E)BRICK m DR. PRIOR TO THEISSUANCEOFANYCONSTRUCTIONPERMITS,THEAPPLICANTSHALLINCORPORATEANYCONSTRUCTIONBESTMANAGEMENT ■ CADWELD WA SQUARE H PRACTICES NECESSARY TO COMPLY WITH THE GINS MUNICIPAL CODES INTO THE CONSTRUCTION PLANS OR SPECIFICATIONS. d27. PRIOR TO THE ISSUANCE OF ANY CONSTRUCTION PERMITS,THE APPLICANT SHALL SUBMIT A WATER POLLUTION CONTROL PLAN WPCP).TIE ® (EI MASONRY • WPCP SHALL SE PREPARED IN AOCORDANCE WITH THE GUIDELINES IN APPENDIX E OF THE CITTS STORM WATER STANDARDS E.:?, GROUND ACCESS WELL MALL O • O 2B. THIS PROJECT PROPOSES NO DEVELOPMENT IMPROVEMENTS OUTSIDE THE EXISTING BUILDING FOOTPRINT FOR THIS DISCRETIONARY I CONCRETE B REVIEW AND THEREFORE DOES NOT REQUIRE ANY PERMANENT STORM WATER BEST MANAGEMENT PRACTICES. �E ELECTRIC BOX 9585 SW WASHINGTON 5O. RD. X 20. THIS PROJECT PROPOSES NO WORK WITHIN THE PUBLIC RIGHT-OF-WAY. EARTH O p TELEPHONE BOX PORTLAND, OR 97216 -DO'{'OO*( GRAVEL -j'Ti' LIGHT POLE IN-BUILDING STORM WATER QUALITY NOTES CONSTRUCTION BMPS: ® PLYWOOD G THIS PROJECT SHALL COMPLY WITH ALL REQUIREMENTS OF THE STATE PERMIT. 0 AND.MONUMENT IL ic NOTES 1-8 BELOW REPRESENT KEY MINIMUM REQUIREMENTS FOR CONSTRUCTION MPS. I SAND A 1. SUFFICIENT BMPS MUST BE INSTALLED TO PREVENT SILT,MUD OR OTHER CONSTRUCTION DEBRIS FROM BEING TRACKED INTO THE ADJACENT STREET(S)OR STORM 4 SPOT ELEVATION ® WOOD CONT. WATER CONVEYANCE SYSTEMS DUE TO CONSTRUCTION VEHICLES OR ANY OTHER CONSTRUCTION ACTIVITY.THE CONTRACTOR SHALL BE RESPONSIBLE FOR O CLEANING ANY SUCH DEBRIS THAT MAY BE IN THE STREET AT THE END OF EACH WORK DAY OR AFTER A STORM EVENT THAT CAUSES A BREECH IN THE INSTALLED n CONSTRUCTION IMPS. , SET POINT I`1 WOOD BLOCKING O 2,ALL STOCK PILES OF UN-COMPACTED SOIL AND/OR BULGING MATERIALS THAT ARE INTENDED TO BE LEFT UNPROTECTED FOR A PERIOD GREATER THAN SEVEN F CALENDAR DAYS ARE TO BE PROVIDED WITH EROSION AND SEDIMENT CONTROLS,SUCH SOIL MUST BE PROTECTED EACH DAY WHEN THE PROBABILITY OF RAIN IS 4099 =ISTEEL g OR GREATER A REVISION —T/E — OVERHEAD SERVICE J 3. A CONCRETE WASHOUT SHALL BE PROVIDED ON ALL PROJECTS WHICH PROPOSE THE CONSTRUCTION OF ANY CONCRETE IMPROVEMENTS THAT ARE TO BE POURED IN CONDUCTORS o PLACE ON THE SITE — A — COAXIAL CABLE N CENTERLINE A ALL EROSION/SEDIMENT CONTROL DEVICES SHALL BE MAINTAINED IN WORKING ORDER AT ALL TIMES. - F FIBER so 5. ALL SLOPES THAT ARE CREATED OR DISTURBED BY CONSTRUCTION ACTMIY MUST BE PROTECTED AGAINST EROSION AND SEDIMENT TRANSPORT AT ALL TIMES. — — — PROPERNAFASF LINE —PEE - POWER AND FIBER JURISDICTION MHNOVAL STAMP el B. THE STORAGE OF ALL CONSTRUCTION MATERIALS AND EQUIPMENT MUST BE PROTECTED AGAINST ANY POTENTIAL RELEASE OF POLLUTANTS INTO THE ENVIRONMENT, X — CHAIN LINK FENCING DEPARTMENT FOR DOR A ULAND USE U DEPARTMENT FOR RTMESTRVCTIVry O Q g MATCH LINE 0w 0 w0 W000 FENCE SHEET TITLE A OVERHEAD PoWER LINE 11 GENERAL FIRE NOTES: SI-- WORK POINT LAP BURIED POWER LINE NOTES & M 1. CODEGGSUNDERGOINGCONSTRUCTION,ALTERATION,OR DEMOLITION SHALL BE IN ACCORDANCE WITH 2O14 OREGON FIRE CODE AND ALL GOVERNING GROUND CONDUCTOR —SIT OVERHEAD TELEPHONE LINE LEGEND M J 2. ADDRESS SHALL BE PROVIDED FOR ALL PROPOSED AND EXISTING BUILDINGS IN A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR —UST— BURIED TELEPHONE LINE B ROAD FRONTING THE PROPEAN(201A OREGON FIRE CODE SECTION 505.1) T TELEPHONE CONDUIT -_Li-Id WATERLINE SHEET NUMBER �A p 3. DECORATES MATERIALS SHALL BE MAINTAINED IN AFL MERETARDANT CONDIITON.)201A OREGON ARE CODE SECTION 808.1) • • O _ —SS BURIED DRAINSE T-2 N. PORTABLE FIRE EXTINGUISHERS:AT LEAST ONE FIRE EXTINGUISHER WITH A MINIMUM RATNG OF 2-A-10B:C SHALL BE PROVIDED WITHIN 75 FEET MrWMUM _ — ELECTRICAL CONDUIT FTRAVEL DISTANCE FOR GC/U SQUARE ORPORTIDN THEREOF ON EACH FLOOR(20 OREGON FIRE CODE SECTION B08.1.1 AND SECTION 008.3.1) (POWER) �S0— BURIED STORM 2 GENERAL NOTES 4 LEGEND 3 NOT USED 2 li • I DISCLAIMER I THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND SURVEY.ALL PROPERTY LINES,EASEMENTS, I LANDLORD SIGNATURE ONSTRU'TIo TAECDOESNOTGU RANTEETHEACCURACY OF SAID PROPERTY LINES,EASEMENTS,ROADS AND SETBACKS / 44 C°.. I L SING I �_ , lit ` ' 7 � ' 11 I 1---- -„,,„ 7 0 q(� It B A VIOL/JON OF LAW FOR ANY PERSON.UNLESS 1NEr IIIII�� ® ®0 OOW / /, ARE ACTING MOM THE dRECTaNOFAL6:ENslD I j L �i PROFE991CNAL ENGINEER.TO ALTER THIS DOE,IMF? BUILDING same/5, , /'A Z I Z in J T • •Mobile°• �J I Ld / 8960 ALDERWOOD ROAD SITE PARCEL NUMBER: 1 PORTLAND,OR 97220 / iii r 1512QW0030D I I / JURISDICTION. L CITY OF TIGARD ' ZONING: TechnologyAssociates IM PROPERTY LINE NE ////// PNW MARKET OFFICE/ 7117 SW BEVELAND STREET, PROPERTY LINE PROPERTY LINE: r / = TICARD OR98006 SUITE 101 —— / /�� i / ', /iiaiiaiiaia�� / PROPERTY LINE IaO NEW T-M°BILE >r TechnologyAssociates L EQUIPMENT 8 ANTENNA I AREA,LOCATED ON 1ST _ ARCHITECTURE&ENGINEERING ���.dd56dV�� % % "°°R OF BD"DI"D SW WASHINGTON SQ. RD. _ CCC��- 2851 GAMING DEL RIo SOUTH,STE.zoo 1 PROPERTY uN � SAN DIEGO,CA 92108 it - E ,. r / /� 4 Z j NEW T-MOBILE EQUIPMENT AREA IN J OIISB"pls ATC COMMENTS MGM EXISTING RST tO ` ////// % / FLOOR,NEW TI-MOBILE FPMENT IBER DEM ON FIMA D :P 2 0/11012015 REVISEDE.SNEETS EL PROPERTY LINE 16 — LOCATED WITHIN EXISTING TELCO ROOM p.� / I� 1 OR]]]AI] NEWaF MORAN MOM 9 1 ON 1ST FLOOR FOR EQUIPMENT PLAN SEE: "� / 17 2 ® 4�Y a( a �� D CBOIIDOI] ISSUED Fog 1DJ%CDVIEREVIEW MGM W fY(�^Y��' 1 A Od911M1] ISSUED FOR 9R%GD REVIEW �� © w I 'K A I A,I REV DATE DESCRIPTION BY Li POYHO24A t A i_EX STING TREES YP) P n L ® rai/ —— — — 4 WA SQUARE \ LPROP ERTYUNE E%I9TING ` MALL 51P73 / / CEMETERY / o s I. ' 1 M 9585 SW WASHINGTON SQ. RD. 0 _ _ — _ _ — _ _ PORTLAND,OR 97216 W ®Q IN BUILDING p SQL 1 i/ ///�i��ii/////////// j o 1 0 %//////////////////// G111 ///////�/�i .� I 0 / a Qj 000000® I Al / m �® 1 _ ` �/ JIMBODIDNAPPROVAL STAMP M % DEPARTMENT FOR LAND USE ry �\E DEPARTMENT FOR BUILDING 6ND JOE UCT[M 5 y� SHEET TITLE o \CO, , i. SITE PLAN 0II,� -0 A- i w SITE PLAN 200®O' S(OR)E01/2'=200'-0'(11a1T) 1 DISCLAIMER THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF -- A CURRENT LAND SURVEY.ALL PROPERTY LINES,EASEMENTS. LANDLORD SIGNATURE AND CONSTRUBCCKS SHALL BE VERIFIED PRIOR TO START OF TONSTAEC DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINES,EASEMENTS,ROADS AND SETBACKS. JCPENNEY I. I I IT RVIOLATIONA VIOLATION 6 LAW FOR ANT PERSON.UNLESS]XEY ARE ACTING VILER)NE DIRECTION Of A LICENSW ARE ENGINEER.TO ALTER THIS DOCUMENT T ••Mobile®- 1 NEW T-MOBILE NODE AREA,NODE DESIGNATION:P02005ZA,FOR 1 EQUIPMENT PLAN SEE: 89PORTIAND,OR 97220 ROAD NEW T-MOBILE FIBER ROUTE FROM Q. EXISTING TELCO ROOM TO FLEXI I I'- ZONE MICRO ANDFLE%RITE Technology ASSoclates ,r' ANTENNA LOCATIONS.ATC TO RUN DICK'S r POWER9 FIBER FROM HEAD END PNW MARKET OFFICE SPORTING L-(I ROOM TO SMALL CELL ATC TO BRING 7117 SW BEVELAND STREET, GOODS 200 AMP SERVICE TO HEAD END SUITE 101 SPACE NEW 2-B CONDUITS WITH — TO EXISTING CEILING. TOETAALOUNTEO SUITE 101 006 J n DISTANCE TO BE VERIFIED BY / _ CONTRACTOR. T I- NEW T-MOBILE EQUIPMENT AREA(HUB IT1 ® I I FOR POYH024ALOCATIONIINEXISTING Technology 4 Associates 4 / [ EQUIPMENT ROOM AND NEWT-MOBILE C I FIBER DEMARC LOCATED WITHIN ARCHITECTURE&ENGINEERING \ EXISTING TELCO ROOM,FOR - [[ EQUIPMENT PLAN see. 2851 CAMINO DEL RIO SOUTH,STE.200 .1 L I I i a. SAN DIEGO,CA 92108 r L. jj J I � 1 rUr _ ___ 1 \ / L I- 1--- - S IP20,201S ATO CoMMENTS MGM �� I CR02501) REVISEDE AURAM! EL 4 I W'311101) NEW AP MAMMA MGM 0 09IIRAS17 RAVED FOR 10014CD RENEW SCM I - rE A MN R01] ISSUED FOR WYCOREVIEW mum \ r REV DATE DESCRIPTION BY i�NEW T-MOBILE NODE AREA.NODE L. DESIGNATION:P02000ZA,FOR POYH024A EQUIPMENT PLAN SEE' I -- L—j F—F—F—F—FT—P P I F F FF { R MACYS ❑ 4 © U SEARS C Li WA SQUARE ev 4 _ MALL g L 4 1 r_ • 9585 SW WASHINGTON SQ.RD. I �..-- _ PORTLAND,OR 97216 CI L NEW T.MOBILE NODE AREA,NODE u DESIGNATION:P02001ZA,FOR — EQUIPMENT PLAN SEE: A IN-BUILDING w __ NEW T-MOBILE NODE AREA,NODE R DESIGNATION:P0200SZA.FOR r I _ 11 O EQUIPMENT PLAN SEE: �� ( � IV u. A I I L T I I NEW T-MTBINE NODE AREA,NODE S DESIGNATION:P02002ZA.FOR — O LI Li/ — EQUIPMENT PLAN SEE: n2 ink I QD Ur / W \> O — NORDSTROM VD JURISDICTION APPROVAL STAMP rMEN1 I DA LANDUSE6D '�I — — OEPARTAENTGO0.BALDING SCgISTiUCTDN a. \ I- ___ T 1ST FLOOR / PLAN / A,\ ---le SHEET SHEET NUMBER w 60 0 30. 60. SCALE: 1-=60'-0-(24x38) o A-2 FIRST FLOOR PLAN (FINAL) ® (OR) 1/2 =ryyD ,,,x,,, 1 NOTE: 1. FOR SMALL CELL ROOM LOCATIONS,REFER TO FLOOR PLAN ON SHEET A-2. LANDLORD SIGNATURE 2. THE DISPLAYED PLAN D TYPICAL FOR NODE LOCATIONS'P02401ZA P02402ZA,P0024032A,P024042A AND P02405ZA. tW.O / EXISTING EQUIPMENT ROOM '1 s 9Z12,11////////071GZ7/X'//////////G/-%%z Y-//,7/,/, /, J N IS A VIOLATION OF LAW FOR ANY PERSONUNLESST1EY NEW TMOBI LE LEASE AREA AI( T ME ACTING UNDER THE DIRECTION OF A LICENSED PRKESSY VIAL ENGINEER.,A TER TI CVOCVM[N r I M I NEW T-MOBILE 19"RACK(ALL NEW ROUTERS w� • D AND AC/DC CONVERTER TO BE MOUNTED T I INSIDE RACK) i ■■Mobile , Ir / i III II it w I NEWT-MOBILE FIBER ROUTE FROM EXISTING 8960 ALDERWOOD ROAD T, u 9 W TELCO ROOM TO FLEXI ZONE MICRO AND PORTLAND,OR 97220 FLEXI LITE ANTENNA LOCATIONS.ATC TO 2 FUTURE FUTUREI RUN POWER&FIBER FROM HEAD END ROOM CARRIER CARRIER T TO SMALL CELL.ATC TO BRING 200 AMP O ID'M ID'X3' w I SERVN:ETO HEAD END SPACENEW 2"B Technology ASSociates 0 EQUIPMENT E AREA Y Z W CONDUITS WITH POWER ANO FIBER ROUTE AREA AREA MOUNTED TO EXISTING CEILING.TOTAL w'1( - -- -E - T U 1A d DISTANCE TO BE VERIFIED BY CONTRACTOR. PNW MARKET OFFICE 6 FUTURE FUTURE AI7117 SW BEVELAND STREET, 5 Y CARRIER CARRIER I Eln°m 1IPM5' 10401 I SUITE 101 - EQUIPMENT EQUIPMENT TIGARD,OR98006 10 AREA 4 NEW T-MOBILE(FLEXI ZONE MICRO)FWIB 2W (1 PER NODE LOCATION,5 TOTAL) / IL. AI TechnologyAssociates ARCHITECTURE&ENGINEERING 4 2851 CAMINO DEL RIO SOUTH,STE.200 1 SAN DIEGO,CA 92108 JW I EXISTING OVERHEAD CABLE LADDER EXISTING PANEL 2A 120)340V,30,514,203A NEW NEW T-MOBILE(FLEXI ZONE MICRO) FA T-MOBILE IS"RACH LE POWER SOURCE TO NEW FW (1 PER NODE LOCATION,5 TOTAL) ILE I Ali If 7016 ATC COMMENTS UM./ ®IV 2 MI�NSB1x REVISED EbMEETS EL ■ EXISTING FUSED DISCONNECT SWITCH YOU C�yy /// N/ I eMvm1) NEW RFIXAGRAM P//� //.%/:% / 4 0 OW213017 ISSUED FOR I WNCD RENEW MGM A DNGIRUI) ISSUED FOR MJN RENEW MGM / 11 REV DATE DESCRIPTION B" / Y/� A EXISTING TELCO BOARD r NEW T-MOBILE(FLEX)CITE BTS)FOFA POY H 024A EXISTING (1 PER NODE LOCATION,5 TOTAL) � STAIRS (TYE,/ 7WAIN" WA SQUARE Ill 00 NEW T-MOBILE FIBER ROUTE FROM EXISTING TELCO ROOM MALL I..0TO FLEXI ZONE MICRO AND FLEX)LITE ANTENNA LOCATIONS. E I /. ATC TO RUN POWER S FIBER FROM HEAD END ROOM TO I I I HEAD END SPACEC NEW S O CONDUITS ATC TO BRING BRX POWER AND0 AMP SERVICET FIBER ROUTE 9585 SW WASHINGTON SQ.RD. V MOUNTED TO EXISTING CEILING.TOTAL DISTANCE TO BE PORTLAND,OR 97216 VERIFIED BY CONTRACTOR. IN-BUILDING W V 7 , / / ® // s / EXISTING EXISTING 09. 4 %/ SWITCH GEAR SWITCH GEAR I 0 V TJAOB E2 MY(FIBER DEFAME)DEFAME) i T I LOCATED IN EASON*TELCO ROOM i 1 I11 S. ■ x Lj-+ j—a—e—,— 4 y�%L NAPPROVAL I n El I T n 1-�1 n I I r1 r1 'UDEPARTMENT FOR LAND USES DEPARTMENT FOB WILDING S CONSTRUCTION a SHEET TITLE vi EQUIPMENT w PLANS w A h - A-3 NUMBER o SCALE: 3/B">•t•-0^(24:361 EQUIPMENT PLAN FIRST FLOOR (FINAL) O® SCALE: 1l4"= -0(11917) I ALL NODE LOCATIONS (FINAL) - TYPICAL 0 '' z' '' 2 (0R) DVEl"=V-0"(29E2 ® (GRI 3116"=1'-0"(11A1T) "A'.DIA.OF CROWN DIAMETER TO NOKIA FLEXI ZONE SMALL CELLS:FWIB BE THE DIAMETER OF THE WALL IB„ OPENING PLUS t' DIMENSIONS: SAND: 4 HEIGHT'. 9.T2' UL: 1710-1755 MHz FIRE-RATED GYPBDSTUD WALL ASSEMBLY EXISTING BUILDING WALL WIDTH: 12.8T DL: 2110.2155MHz DEPTH: 3 36' BANDWIDTHS: 5.10,15,AND 20 MHz 3'MAX DIA.MTL.PIPE.PROVIDE S NEW UNISTRUT WEIGHT: 11.46 LBS CARRIERS: 1 - NOM.t'ANNULAR SPACE AROUND MOUNTING PIPE 1 H.-�"II\� - 12 8T k OPTIONAL FORMING MATERIAL-RECESSED -.I Ilk V2'FROM THE SURFACE FOR FS900 =: MATERIAL(MINERAL WOOL. I♦l'11 J POLYSTYRENE...ETC.I l TRENCO THROUGH-PENETRATION I 1 I I FIRE-STOP SYSTEMS,ASTM E 814,UL I 147P,UL 2079 ADD.MATERIAL ADDED TO FORM sir _ CROWN AROUND CONDUIT AND �1 Il�k (NI EQUIPMENT - - 1'•,• III I rl l It Ili \ LAPPING 1"BEYOND OPENINGMII©© III II �,. insxvgUwrrox or LAW FOR ANY PERSON.UNLESS THEY ENSED FRAMED WALL PENETRATION vvv _ _ _ ( OF SSIONAL1ENOINCF DIOECTaRTHISO OF A CIIMrNr PROFESSIONAL EACTIND UNDER THE DIRECTION FRONT VIEW TOP VIEW T "'sR n"°`n"uurx SECURE TO RRH MOUNT USING: i ■.mobile. Q STEEL STUDS:I l4'-xl'SCREW . ---/�� ‘-..:„..rr3 t14'MIN.CONG WALL OR CMU. Q WOOD:12'O LAG SCREWS WITH T MIN.EMBED.11 UOPENING TO PROVIDE Y4'MAX. QGDNCRETE:1170 HILTI I(B-R WITH 2'EMBED. Iu6960 ALDERWOOD ROAD ANNULAR SPACEAROUND PIPE QCMU:1?01MLTI KB3NTTN 2-1N'MIN.EMBED. N"T'Tl_L1 sar PORTLAND,OR 97220 IF THRU-BOLTED:Ilr0 A307 THRU-BOLTS AND NUTS. IMIIMIBOTTOM VIEW BIDE VIEW - f0 PAX METAL PIE SCALE ' SCALE N.T.S. SCALE Technology Associates NOT USED N.T.S. 10 EQUIPMENT MOUNTING 4 FWIB 1 pNw MARKET OFFICE TREMCO THROUGH-PENETRATION N.T.S. FIRE-STOP SYSTEMS.ASTM E Pa.UL 7117 SW BEVELAND STREET, phi. 1479:UL2079 NOKIA:FLEXI LITE BTS 1900(FQFA) TIGARD SUITE O 101 MINERAL WOOL(4 PCF)PACKED INTO 98006 ANNULAR SPACE AND RECESSED 12' FREQUENCY BAND' SUPPORTS WCDMA RAND II(PCS) FROM WALL SURFACES UPLINK 1850-1910 MHz,DOWNLINK 1930-1990 MHz CONCRETE PENETRATION CAPACITY: HSPA UP TO 84 Mbps RECEIVE SENSITIVITY: SINGLE BRANCH-107dBm TO-121d8m Technology Associates CONDUIT FLOOR CLAMP.TYP. TEMPERATURE RANGE: -35°C TO+SVC WATER INGRESS PROTECTION CLASS. IP65 ARCHITECTURE&ENGINEERING Ella ANCHOR BOLT OR EXISTING CONCRETE DIMENSIONS,HxWSO: 14.96'x 12.83'x 3.98'(360mm x 326mm x101mm) 2851 CAMINO DEL RIO SOUTH,STE.200 11 ,1z TREMCO APPROVED EQUIVALENT CEILING SLAB WEIGHT: 27.6 lb(12.5 kg) SAN DIEGO,CA 92108 I� FITHROUGH-PENETRATION ITYP. • • POWER UTPU INPUT 1FROM VAC,250m S(P100) FIRE-STOP SYSTEMS,ASTME OUTPUT POWER: FROM 250mW(PICO)TO5W(MICRO)IN 1tl8 STEPS 814,UL 14]9:UL 2079 miribi ME I FIBER AND POWER 3 01l194918 AnCCYMENi4 MGM CONDUIT PER PLAN(4'-MAX.) I SERVICE CONDUIT s omwe9+e REVISED ESNEETs EL ill EXISTING CEILING COUPLING(TYR) I.I AMA (E)CONCRETEFLDOR J\ I 1 ourzoaun NEW NF 0RIWI MOM ROD(TTHREADEDLENGTH NGTEEL I /,/--\'\I STEEL WASHER CONCRETE FLOOR PENETRATION ROD(TVP.)LENGTIR AS AND NUT(TYP.) 9 O9/NR91T ISSUED Fort1W%fA REVIEW MGM NECESSARY TO SUIT , A C001001T ISSUED FOR 99iED REVIEW NOTE: FIELD CONDITIONS REV DATE DESCRIPTION By I CONTRACTOR TO X-RAY PRIOR TO DRILLING OR CORING TO LOCATE(E) nI Iu RE.UAR.DONOT CUT RE.60R. SPACING OF CHANNELS GALVANIZED STEEL •--..•....-�•-��-�...+--..w�. SHALL BE PER NEC CHARNEL.UNITRUT 2.PENETRATIONS THRU WALLS SHALL COMPLY P.1000OR APPROVE P OY H 024A F RATING-PENETRATIONS 4'0 OR LESS. EQUIVALENT T RATING-PENETRATIONS LARGER THAN 4-0,PENETRATIONS Q CORRIDOR CLOS.WHICH ARE NOT RATED BELOW Lu Old! 3 PENETRATIONS THOU FLOORS/CE ILINGS SHALL COMPLY WA SQUARE PENETRATIONSIARGER n THAN IV,PENETRATIONS NOT CONTAINED WRN H A WALL ISOMETRIC VIEW MALL O 4.ALL PENETRATIONS SHALL CONFORM TO JURISDICTIONS BUILDING CODES. 8 0 9 SCALE SCALE Q SCALE SCALE 9585 SW WASHINGTON SQ.RD. W NOT USED N.T.S. 11 PENETRATION DETAIL N.T.S. 8 CABLE MOUNTING N.T.S. 5 BASE STATION SPECIFICATIONS N.T.S. 2 PORTLAND, OR 97216 COOPER B-LINE TWO-POST w, $ NOKIA FLEXI ZONE SMALL CELLS:FWFA NETWORK EQUIPMENT RACKLu IN BUILDING DIMENSIONS: •BAND'. 2/25 M III HEIGHT: 9.72' UL: 1850-I9I5 MHz 0 DIMENSIONS 19'RACK WIDTH MOTH: 1267' DE. 1930-1995 MHz w O A'OVERALL HEIGHT 38'-tp0' II I' DEPTH: 472' AN 6: 5,10,i6,AN020 MHz 4 'B'OVERALL WIDTH 205716' 04111 WEIGHT: 13.66 LBS CARRIERS: 1 0O C'PANEL MOUNTING 16 Y16' i' 12.67- z 'D'USABLE INSIDE WIDTH P 3/4' F 'E BASE ANCHOR SPACING 16' rc-C W Q a NOTE5 n 1. Y12-2d PANEL MOUNTING HOLES. 2. CONFORMANCE TO EINECA-310-E, r r I 1 3. LOAD RATING'.1200 LBS. • f H�TI J l JURISOCTION APPROVAL STAMP DISTRIBUTEDx WEIGHT ACITY FORT EE.HHEQHET6ILY IYP'0 HOLESTTOP.ED • fl ,II'�IIIII,• rl,ll rllelll•..C yI�..I 41I o�ulnDEARTMENFOR FOR USF 9 OF THE RACK. 4. DOUBLE SIDED UNIVERSAL (5l('.Ur)MOUNTING SPACING. FRONT VIEW TOP VIEW SHEET TITLE :It. MATERIAL:6061-T6 ALUMINUM ALLOY N DETAILS .,1%,... .n1 • a ANCHORAGE USE. C0_--JIQ� � Jy 1 Q ROOD:IR'O LAG SCREWS WITH 2'MIN.EMBED. O • ug tll� I SHEET NUMBER e Q CONCRETE:12'O HILTI KB-TZ WITH 2'EMBED. ���� .� BOTTOM VIEW SIDE VIEW '1.' QCMU 1 fro BOLTE DTI KB32"0 307WITHTH1N'MINEMBED. EQUIPMENT CONFIGURATION IF THRU-BOLTED 1)70 A307 THRU-BOLTS AND NUTS. A..4 w SCALE SCALE SCALE NOT USED 12 RACK SPECIFICATIONS N.T,S- 6 FWFA N.T.S. I N.T.S. 1.GENERAL REQUIREMENTS 4.SUBSTITUTIONS EQUIPMENT POWER SHALL BE 200A 10.3W,120208V OR 5. ALL MIRING SHALL BE COPPER 75'C U.N.O. A. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE A NO SUBSTITUTIONS ARE ALLOWED. ALL WIRE AND CABLE SHALL BE COPPER.500 VOLT,812 AWG 120/240V, LATEST RILES AND REGULATIONS OF THE NATIONAL ELECTRIC CODE MINIMUM UNLESS SPECIFICALLY NOTED OTHERWISE ON THE 8. CONDUIT REQUIREMENTS(TYP.,U.N.O.I AND ALL STATE AND LOCAL CODES.NOTHING IN THESE PLANS OR 5.TESTS DRAWINGS.CONDUCTORS BID AWG AND SMALLER SHALL BE SOLID. UTILITY RECEPTACLE IS A GFCI DUPLEX OUTLET INSTALLED IN UNDERGROUND:PVC(SCHED 40 OR 80) SPECIFICATIONS SHALL BE CONSTRUED AS TO PERMIT WORK NOT CONDUCTORS 88AWG AND LARGER SHALL BE STRANDED.TYPE THE DEADFRONT OF PPC. INDOOR. EMT(RGS IN TRAFFIC AREAS) CONFORMING TO THE MOST STRINGENT OF THESE CODES SHOULD THHN INSULATION USED UNLESS CONDUCTORS INSTALLED IN OUTDOOR: RGS(ABOVE GRADE) CHANGES BE NECESSARY IN THE DRAWINGS OR SPECIFICATIONS TO A. BEFORE FINAL ACCEPTANCE OF WORK,THE CONTRACTOR CONDUIT EXPOSED TO WEATHER.IN WHICH CASE TYPE THWN 3. PROVIDED A MIN.38-WORK CLEARANCE IN FRONT OF PANELS/ MAKE THE WORK COMPLY WITH THESE REQUIREMENTS.THE SHALL INSURE THAT ALL EQUIPMENT,SYSTEMS.FIXTURES,ETC., INSULATION SHALL BE USED. SERVICE EQUIPMENT. 7, APPLETON EMERGENCY GENERATOR PLUG AT 38-AF.F. PRE WORKING SATISFACTORILY AND TO THE INTENT OF THE CONTRACTOR TO VERIFY EXACT LOCATION WITH LANDLORD AND CONTRACTORSHRLIMMEDIATELY NOTIFY THE ARCHITECT IN DRAWINGS. WRITING AND CEASE WORK ON PARTS OF THE CONTRACT WHICH ARE D. PROVIDE GALVANIZED COATED STEEL BOXES AND ACCESSORIES 4, ALL BREAKERS IN THE ELEC.PANEL ARE RATED 10,000 RUE UTILITY COORDINATOR. AFFECTED. SIZED PER CODE TO ACCOMMODATE ALL DEVICES AND WIRING. SYMMETRICAL AMPS,240V MAX 75'C. 6.PERMITS B. PLACE TRUE TAPE-AND PULL ROPE IN THE CONDUITS AS REQUIRED. B. THE CONTRACTOR SHALL MAKE A SITE VISIT PRIOR TO BIDDING AND E. DUPLEX RECEPTACLES SHALL BE SPECIFICATION GRADE WITH CONSTRUCTION TO VERIFY ALL EXISTING CONDITIONS AND SHALL A. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAXING OUT AND WHITE FINISH(UNLESS NOTED BY ARCHITECT/ENGINEER).20 AMP, NOTIFY THE ARCHITECT IMMEDIATELY UPON DISCOVERY OF ANY PAYING FOR ALL THE REQUIRED PERMITS,INSPECTION AND 125 VOLT.THREE WIRE GROUNDING TYPE.NEMA 5-20R.MOUNT SCALE DISCREPANCIES THE CONTRACTOR ASSUMES ALL LIABILITY FOR EXAMINATION WITHOUT ADDITIONAL EXPENSE TO THE OWNER. RECEPTACLE AT•1Z ABOVE FINISHED FLOOR UNLESS OTHERWISE ELECTRICAL NOTES 2 FAILURE TO COMPLY WITH THIS PROVISION. INDICATED ON DRAWINGS OR IN DETAILS,WEATHERPROOF N.T.S. 7.GROUNDING RECEPTACLES SHALL BE GROUND FAULT INTERRUPTER TYPE C. THE EXTENT OF THE WORK IS INDICATED BY THE DRAWINGS, WITH SIERRA}AND-S LIFT COVERPLATES. SCHEDULES,AND SPECIFICATIONS AND IS SUBJECT TO THE TERMS A. THE CONTRACTOR SHALL PROVIDE A COMPLETE.AND APPROVED A AMPERE ELEC ELECTRICAL MFR MANUFACTURER SAF SAFETY AND CONDITIONS OF THE CONTRACT.THE WORK SHALL CONSIST OF GROUNDING SYSTEM INCLUDING ELECTRODES.ELECTRODE F. TOGGLE SWITCHES SHALL BE 20 AMP,120 VOLT AC,SPECIFICATION ACCA ANTENNACABLECOVER EMT ELECTRICAL METALLIC TUBING nsAVOUTCR OF LAW FOR ANY PERSON.UNLESS ntEr FURNISHING ALL LABOR,EQUIPMENT.MATERIALS AND SUPPLIES CONDUCTOR,BONDING CONDUCTORS,AND EQUIPMENT GRADE WHITE(UNLESS NOTED OTHER'M9E)FINISH.MOUNT MIN MINIMUM SDBC SOFT BARE COPPER AAE ACTING UNDER THE DIRECTOR OF A LICENSED NECESSARY FOR A COMPLETE AND OPERATIONAL ELECTRICAL CONDUCTORS AS REQUIRED BY ARTICLE 25D OF NATIONAL SWITCHES AT A46-ABOVE FINISHED FLOOR. ASSEMBLY ENCL ENCLOSURE MLO MAIN LUGS ONLY SEC SECONDARY v FISSIONAL ENDINFFR,TO AI TEO Ti Mrs DOCUMENT. SYSTEM.THE WORK SHALL ALSO INCLUDE THE COMPLETION OF ALL ELECTRICAL CODE. AIC AMPERE INTERRUPTING EXIST EXISTING MTD MOUNTED S.N. SOLID NEUTRAL ELECTRICAL WORK NOT MENTIONED OR SHOWN WHICH ARE G. PANELBOARDS SHALL BE DEAD FRONT SAFETY TYPE WITH CAPACITY FAG FACTOR WO MOUNTING SURF SURFACE NECESSARY FOR SUCCESSFUL OPERATION OF ALL SYSTEMS B. CONDUITS CONNECTED TO EQUIPMENT AND DEVICES SHALL BE ANTI-BURN SOLDERLESS COMPRESSION APPROVED FOR A/PROX APPROXIMATELY F/A FIRE ALARM ARTS MANUAL TRANSFER SNITCH SW SWITCH 1 METALLICALLY JOINED TOGETHER TO PROVIDE AN EFFECTIVE COPPER CONDUCTORS.COPPER BUS BARS.FULL SIZED /,0��1/�m D. THE CONTRACTOR SHALL PREPARE A BID FOR A COMPLETE AND ELECTRICAL CONTINUITY. NEUTRAL BUS,GROUND BUS AND EQUIPPED WITH QUICK- AT AMPERE TRIP FLUOR FLUORESCENT N NEUTRAL TEL TELEPHONE ■ ■ M• e■ OPERATIONAL SYSTEM WHICH INCLUDES THE COST FOR MATERIAL MAKE QUICK-BREAK BOLT-IN TYPE THERMAL MAGNETIC AWG AMERICA WIRE GAGE FT FOOT/FEET IN) NEW TYP TYPICAL AND LABOR, C. FEEDERS AND BRANCH CIRCUIT WIRING INSTALLED IN A CIRCUIT BREAKERS.MOUNT TOP OF THE PANELBOARDS AT 8-3' BATT BATTERY FU FUSE NEMA NATIONAL ELECTRICAL DIG UNDERGROUND NONMETALLIC CONDUIT SHALL INCLUDE A CODE SIZED GROUNDING ABOVE FINISHED FLOOR.PROVIDE TYPEWRITTEN CIRCUIT gp BOARD G GROUND MANUFACTURERS ASSOC. U.L. UNDERWRITERS LABORATORY INC. 8960 ALDERWOOD ROAD E. WORKMANSHIP AND NEAT APPEARANCE SHALL BE AS IMPORTANT AS CONDUCTOR HAVING GREEN INSULATION. THE GROUND DIRECTORY. THE OPERATION.DEFECTIVE OR DAMAGED MATERIALS SHALL BE CONDUCTOR SHALL BE PROPERLY CONNECTED AT BOTH ENDS TO BR BRANCH GEN GENERATOR OH OVERHEAD PORTLAND,OR 97220 REPLACED OR REPAIRED PRIOR TO FINAL ACCEPTANCE IN A MANNER MAINTAIN ELECTRICAL CONTINUITY. H. ALL CIRCUIT BREAKERS,MAGNETIC STARTERS AND OTHER BRKR BREAKER GM GROUND FAULT CIRCUIT P POLE U.N.0 UNLESS NOTED OTHERWISE ACCEPTABLE TO OWNER AND ARCHITECT/ENGINEER ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING BTCW BARE TINNED COPPER WIRE INTERRUPTER PCS PERSONAL COMMUNICATION V VOLT RATING NOT LESS THAN MAXIMUM SHORT CIRCUIT CURRENT SYSTEM VAC VOLT ALTERNATING CURRENT D. REFERMPTO GROUNDNDUCTOAI,GROUND ( (AND DE, ATE BASETRANSMISSIONSYSTEM GND GROUNDING F. COMPLETE THEENTIREINSTALLATION AS SOON AS THE PROGRESS COMPLETE WITH CONDUCTORS,GROUND ROIXS)ANDOESCRIBED TO WHICH THEY MAY BE SUBJECTED. OF THE WORK WILL PERMIT.ARRANGE ANY OUTAGE OF SERVICE TERMINATIONS. C CONDUIT GPS GLOBAL POSITIONING SYSTEM PH PHASE W WATT OR WIRE Technology Associates WITH THE OWNER AND BUILDING MANAGER IN ADVANCE.MINIMIZE I. GROUND RODS SHALL BE COPPER CLAD STEEL,S/S-ROUND AND IO' CAB CABINET GR GROWTH PNLBD PAELBOARD W/ WITH DOWNTIME ON THE BUILDING ELECTRICAL SYSTEM. E. ALL GROUNDING CONDUCTORS SHALL BE SOLID LINED COPPER AND LONG.COPPERWELD OR APPROVED EQUAL CB CIRCUIT BREAKER HOBO HARD DRAWN COPPER WIRE PPC POWER PROTECTION CABINET W/O WITHOUT pNW MARKET OFFICE ANNEALED 52 UNLESS NOTED OTHERWISE. CKT CIRCUIT HPS HIGH PRESSURE SODIUM PRC PRIMARY RADIO CABINET XFER TRANSFER 7117 SW MARKENO$TREET, G. THE ENTIRE ELECTRICAL SYSTEM INSTALLED UNDER THIS CONTRACT 10. INSTALLATION COAT CONTINUOUS LG LENGTH PRI PRIMARY XFMR TRANSFORMER SUITE 101 SHALL BE DEUVERED IN PROPER WORKING ORDER.REPLACE, F. ALL NON-DIRECT BURIED TELEPHONE EQUIPMENT CONDUCTORS OEM DEMAND LPS LOW PRESSURE SODIUM POUR POWER XLPE TRANSFORK POLYETHVLErvE WITHOUT ADDITIONAL COST TO THE OWNER,ANY DEFECTIVE SHALL BE 82 STRANDED,GROUND THHN(GREEN)INSULATION. A PROVIDE SUPPORTING DEVICES FOR ALL ELECTRICAL TIGARD,OR 98006 MATERIAL AND EQUIPMENT WITHIN ONE YEAR FROM THE DATE OF EQUIPMENT.FIXTURES.BOXES,PANEL.ETC..SUPPORT LUMINARIES (E) EXISTING MAX MAXIMUM RCPT RECEPTACLE FINAL ACCEPTANCE. G. ALL GROUND CONNECTIONS SHALL BE MADE WITH'HYGROUND- FROM UNDERSIDE OF STRUCTURAL CEILING,EQUIPMENT SHALL BE EGR EMERGENCY GEN.RECEPTACLE MECH MECHANICAL RGS RIGID GALVANIZED STEEL COMPRESSION SYSTEM BURNDY CONNECTORS EXCEPT WHERE BRACED TO WITHSTAND HORIZONTAL FORCES IN ACCORDANCE AARA. I. ANY ERROR,OMISSION OR DESIGN DISCREPANCY ON THE DRAWINGS NOTED OTHERWISE. WITH STATE AND LOCAL CODE REQUIREMENTS.PROVIDE PRIOR SCALE 4q Technolo Associates SHALL BE BROUGHT TO THE ATTENTION OF THE ALIGNMENT AND LEVELING OF ALL DEVICES AND FIXTURES. GENERAL ABBREVIATIONS 3 gy ARCHITECT/ENGINEER FOR CLARIFICATION OR CORRECTION BEFORE H. PAINT AT ALL GROUND CONNECTIONS SHALL BE REMOVED. N.T.S. CONSTRUCTION. B. CUTTING,PATCHING,CHASES,OPENINGS:PROVIDE LAYOUT INI. ARCHITECTURE&ENGINEERING GROUNDING SYSTEM RESISTANCE SHALL NOT EXCEED 5 OHMS.IF ADVANCE TO ELIMINATE UNNECESSARY CUTTING OR DRILLING OF y-.( I. -PROVIDE':INDICATES THAT ALL ITEMS ARE TO BE FURNISHED. THE RESISTANCE VALUE IS EXCEEDED,NOTIFY THE OWNER FOR WALLS,FLOORS CEILINGS,AND ROOFS.ANY DAMAGE TO BUILDING -OHT/OHP- OVERHEAD TELEPHONE/OVERHEAD POWER Pa LIGHTING FIXTURE,1/175W METAL HALIDE,HUBBELL CAT 8MIC-0175H-33P 2851 CAMINO DEL RIO SOUTH,STE.200 INSTALLED AND CONNECTED IN PLACE. FUTURE INSTRUCTION ON METHODS FOR REDUCING THE STRUCTURE OR EQUIPMENT SHALL BE REPAIRED BY THE SAN DIEGO,CA 92108 RESISTANCE VALUE. SUBMIT TEST REPORTS AND FURNISH TO CONTRACTOR.OBTAIN PERMISSION FROM THE rr�� J. CONTRACTOR SHALL SECURE ALL NECESSARY BUILDING PERMITS SMART SMR ONE COMPLETE SET OF PRINTS SHOWING'INSTALLED ARCHITECT/ENGINEER BEFORE CORING. OHT OVERHEAD TELEPHONE LINE V 5B'%104Y CU.GND ROD 3O'MIN.BELOW GRADE. AND PAY ALL REQUIRED FEES. WORK-. C. IN DRILLING HOLES INTO CONCRETE WHETHER FOR FASTENING OR 2.EQUIPMENT LOCATION 8.UTILITY SERVICE ANCHORING PURPOSES,OR PENETRATIONS THROUGH THE FLOOR yTF�� 5/8'%10'-D',CU.GND RODIN TEST WELL30'MIN.BELOW GRADE. OlTdrzalS ATE COMMENTS MCra FOR CONDUIT RUNS,PIPE RUNS,ETC.,IT MUST BE DEARLY OHP OVERHEAD POWER LINE INz . mnorzom REVREO C-SHEETS EL A THE DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED A. TELEPHONE AND ELECTRICAL METERING FACILITIES SHALL UNDERSTOOD THAT TENDONS ANODR REIBFORCING STEELWILL LOCATIONS OR ARRANGEMENTS OF CONDUIT RUNS.OUTLETS. CONFORM TO THE REQUIREMENTS OF THE SERVING UTILITY NOT BE DRILLED INTO.CUT OR DAMAGED UNDER ANY I wr22aan NEW RF DIAGRAM M/ EQUIPMENT,ETC..AND ARE TO BE FOLLOWED AS CLOSELY AS COMPANIES,CONTRACTOR SHALL VERIFY SERVICE LOCATIONS AND CIRCUMSTANCES. E POWER RUN e CHEMICAL GROUND ROD(KIT GROUND ROD) 0 GpNpTp1T ISSUED FOR 1001NW REVIEW MOM POSSIBLE.PROPER JUDGMENT MUST BE EXERCISED IN EXECUTING REQUIREMENTS. SERVICE INFORMATION WILL BE FURNISHED BY THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THE SERVING UTILITIES, D. LOCATION OF TENDONS AND/OR REINFORCING STEEL ARE NOT RE A aRD+rzuv ISSUED FOR ROxcD REVIEW Mcr.I E AVAILABLE SPACE AND TO OVERCOME LOCAL DIFFICULTIES DUE DEFINITELY KNOWN AND THEREFORE,MUST BE SEARCHED FOR BY TO SPACE LIMITATIONS OR INTERFERENCE OF STRUCTURE B. CONFORM TO ALL REOUIREMENTS OF THE SERVING UTILITY APPROPRIATE METHODS AND EQUIPMENT VIA X-RAY OR OTHER - T TELCO RUN ■ CADWELD CONNECTION REV DATE DESCRIPTION BY CONDITIONS ENCOUNTERED. COMPANIES. DEVICES THAT CAN ACCURATELY LOCATE THE REINFORCING AND/OR STEEL TENDONS. B. IN THE EVENT CHANGES IN THE INDICATED LOCATIONS OR 9.PRODUCTS TIE POWER/TELCO RVN . MECHANICAL CONNECTION /.HI ARRANGEMENTS ARE NECESSARY,DUE TO FIELD CONDITIONS IN THE E. PENETRATIONS IN FIRE RATED WALLS SHALL BE FIRE U.S.0 POYHOZ4A BUILDING CONSTRUCTION OR REARRANGEMENT OF FURNISHINGS OR STOPPED IN ACCORDANCE WITH THE REQUIREMENTS OF THE . EQUIPMENT.SUCH CHANGES SHALL BE MADE WITHOUT COST, A ALL MATERIALS SHALL BE NEW,CONFORMING WITH THE NEC,ANSI. N PROVIDING THE CHANGE IS ORDERED BEFORE THE CONDUIT RUNS, NEMA AND THEY SHALL BE U.L.LISTED AND LABELED. 11.PROJECT CLOSEOUT -G- GROUNDING CONDUCTOR / HALO GROUND CONNECTION t ETC.,AND WORK DIRECTLY CONNECTED TO THE SAME IS INSTALLED �/�� AND NO EXTRA MATERIALS ME REQUIRED. B. CONDUIT: 1�v ASQUARE WA UPON COMPLETION OF WORK.CONDUCT CONTINUITY.SHORT z C LIGHTING FIXTURES ARESHOWN IN THEIR APPROXIMATE LOCATIONS 1. RIGID CONDUIT SHALL BE U.L.LABEL GALVANIZED ZINC CIRCUIT,AND FALL POTENTIAL GROUNDING TESTS FOR APPROVAL. -� GROUNDING CONDUCTOR fL CIRCUIT BREAKER n COATED WITH ZINC INTERIOR AND SHALL BE USED WHEN SUBMIT TEST REPORTS TO PROJECT MANAGER.CLEAN PREMISES MALL ONLY.COORDINATE THE FIXTURE LOCATION WITH MECHANICALRESULTING w EQUIPMENT TO AVOID INTERFERENCE.COORDINATE THE WORK OF INSTALLED CONCRETE SLABS,IN CONTACT WITH THE OF ALL DEBRIS UNDAMAGED FROM WORK AND LEAVE WORK IN A D THIS SECTION WITH THAT OF ALL OTHER TRADES.WHERE CONFLICTS EARTH,UNDER PUBLIC ROADWAYS,IN MASONRY WALLS OR COMPLETE ANDUNDAMAOEDCONDITION. - CONDUIT UNDERGROUND El UDLITY METER BASE S OCCUR.CONSULT WITH THE RESPECTNECONTRACTOR AND COME N CONTACT WTHHEARTHSHALLBD ON E12 LAPPED WRAPPED WI EXTERIOR.RIGID TH IT IHUNTS WRAP B. PROVIDE PROJECT MANAGER WITH ONE SET OF COMPLETE 9585 SW WASHINGTON SQ.RD. z TO AGREEMENT AS TO CHANGES NECESSARY.OBTAIN WRITTEN ELECTRICAL'AS INSTALLD-DRAWINGS AT THE COMPLETION OF c ACCEPTANCE FROM ARCHITECTENOINEER FOR THE NEW CHANGES ROCE53 NO.9, THE JOB,SHOWING ACTUAL DIMENSIONS,ROUTINGS AND CIRCUITS. FUSE,SIZE AND TYPE AS INDICATED. DI PORTLAND. OR 97216 O BEFORE PROCEEDING. 2. ELECTRICAL METALLIC TUBING SWILL HAVE U.L.LABEL.FITTINGS o 8/ 3.SHOP DRAWINGS SHALL BE COMPRESSION TYPE.EMT SHALL BE USED ONLY FOR C. ALL BROCHURES.OPERATING MANUALS,CATALOG.SHOP INTERIOR RUNS. DRAWINGS,ETC.,SHALL BE TURNED OVER TO OWNER AT JOB SAFETY SWITCH,2P-24M4MOA WHOA FUSES.NEMA 9R �I I IN-BUILDING o COMPLETION. STEPDOWN TRANSFORMER z A. NIA UNLESS NOTED OOTHERWISE. 3. FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L.LISTED LABEL AND ENCLOSURE.SOD CATALOG NO.H2Z2NRB J O MAY BE USED WHERE PERMITTED BY CODE,FITTINGS SHALL BE 'JAKE-OR'SQUEEZE-TYPE.SEAL TIGHT FIE)SBLE CONDUIT. C1 MANUAL TRANSFER SWITCH,2R240V-200A,NO FUSE, ® RECEPTACLE,2P-3W-125V-15A.DUPLEX,GROUND TYPE, o ALL CONDUIT IN EXCESS OF SIX FEET IN LENGTH SHALL HAVE FULL NEMA 9R ENCLOSURE MUSSEL CATALOG 85382 SIZE GROUND WIRE, > LIGHTING FIXTURE.FLUORESCENT,10.94-04'-0',2/40W, FN TOGGLE SNATCH,IP-125V-15A,HUBBELL CATALOG BHBL 6. CONDUITINDICATED RUNS OTHERWISE CONDUIT I INDICATED RUNS ® SURFACE MOUNTING TYPE,HUBBELL LIGHTING CATALOGS 1201CN 22 2 UNLESS INDICARORBELL 80/SW232T PARALLEL OR AT RIGHT ANGLES TO CEILING,FLOOR OR BEAMS. F VERIFY EXACT ROUTING OF ALL EXPOSED CONDUIT WITH LIGHTING FIXTURE.FLUORESCENT,10.94-z e'-0',2J95W, a ARCHITECT PRIOR TO INSTALLING. IT-5=1 SURFACE MOUNTING TYPE,HUBBELL LIGHTING CATALOG SV1P TOGGLE SWITCH,IP-120V-ISA-WE A 1TRNSM232T 5. ALL UNDERGROUND CONDUITS SHALL BE PVC SCHEDULE 40 (UNLESS NOTED OTHERWISE)ATA MINIMUM DEPTH OF 24'BELOW LIGHTING FIXTURE.HIGH PRESSURE SODIUM,CROW,WALL ev GRACE FE' MOUNTING TYPE,HUBBELL LIGHTING CATALOG 184120-307 OS IONIZATION SMOKE DETECTOR W/ALARM HORNS AUXILIARY CONTACT. OR 1/50W,HUBBELL LIGHTING CATALOG BNRG-121 120 VAC,CENTEX PART NO.7100E x 8. ALL CONDUIT ONLY(C,O,)SHALL HAVE PULL ROPE. AApp �j POLE JDRISDCTOM APPROVAL SIAM.. 7. CONDUITS RUN ON ROOFS SHALL BE INSTALLED ON 4 X 4 TKO EXIT SIGN,THERMOPLASTIC LED,SINGLE FACE,UNIVERSAL MOUNTING. DEPARTMENT FOR WE/ SLEEPERS,e'-P ON CENTER SET IN NON-HARDENING MASTIC. W EATTERY PACK.HUBBELL LIGHTING CATALOG WRB DEPARTMENT FOR SIRLONO A CONSTRUE-DON z a COMBINATION,EXIT SIGN 8 EMERGENCY LIGHTING, IT HUBBELL LIGHTING CATALOG OPRC (N)POLE MOUNTED%FMER SHEET TITLE �`11IY� EMERGENCY LIGHTING,2/i0W,HUBBELL LIGHTING CATALOG LI ELECTRICAL p I_J m''E850.2-RBI Q (E)POLEMODNTEDXFMR NOTES NM LIGHTING FIXTURE.HINCANDESCENT, ,WALL z MOUNTING TYPE,HUBBELL LIGHTING CATALOG IX (N)PAD MOUNTED%FMER 0-06-1 SHEET NUMBER 9 S OE UGHTING FIXTURE, O LIGHTING CATALOG 8GL805N QUARTZ,1/300W.HUBBELL ❑� (El PAD MOUNTED XFMER E- ELECTRICAL GENERAL NOTES 1 GENERAL LEGEND N.T.S.A 4 • DISCLAIMER THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND SURVEY.ALL PROPERTY LINES,EASEMENTS. LANDLORD SIGNATURE AND SETBACKS TART OF CONSTRUCTION STAEC DOES NOT GUARANIHALL BE VERIFIED PRIOR TO ES THE ACCURACY OF SAID PROPERTY LINES.EASEMENTS.ROADS AND SETBACKS. JCPENNEV L IT I IT IS A VIOLATION OF LAW POR MT PERSON,UNLESS THEY ARE ACTOR UNDER THE DIRECTION OF ALRHISEO TOFESSIONAL ENSURER ISULLEN IM OC!DUMENT. r" -1 I NEW T.MOBILE NODE AREA,NODE + • ■Mobile®� a L DESIGNATION:P02mva,FOR EQUIPMENT PLAN SEE: 8960 ALDERWOOD ROAD I PORTLAND,OR 97220 r %V® NEW T-MOBILE FIBER ROUTE FROM — O EXISTING TELCO ROOM TO FLEXI ZONE MICRO AND FLEXI LITE Technology Associates ANTENNA LOCATIONS.ATC TO RUN DICES POWER S FIBER FROM HEAD END PNW MARKET OFFICE SPORTING EL. ROOM TO SMALL CELL.ATC TO BRING 7117 SW BEVELAND STREET, GOODY I 200 AMP SERVICE TO HEAD END - SUITE 101 'Li- SPACE.NEW re ROUTE MOUNTED WITH POWER AND FIBER ROUTE MOUNTED TIGARD,OR 98006 4 TO EXISTING CEILING.TOTAL - / - DISTANCE TO BE VERIFIED BY T. CONTRACTOR. I 1 NEWT.MOBILE EQUIPMENT AREA(HUB r1 Ir FOR POYHOXNA LOCATION)INEXISTING Technology Associates L el - l / L EQUIPMENT ROOM AND NEW TIAOBILE J l\ FIBER DEMARC LOCATED WITHIN EXISTING TELCO ROOM,FOR ARCHITECTURE&ENGINEERING L L EQUIPMENT 2851 CAMINO DEL RIO DIEGO,CA 9221OB STE.200 ..I r w®® \ / Lma 4 I 0IR9R0I6 ATE COMMENTS MGM = 2 OIOQRRIS REVISES E-SHEETS EL L. 1 1812,2017 NEW RF DIAGRAM MGM I--' D WRW2012 ISSUED FOR IMILCO RENEW MOM � * - �I A 0891(Al2 V ED FOR KISCO REVIEW MGM REV DATE DESCRIPTION RY I I NEWT-MOBILE NODE AREA,NODE -� POYH024A L. EQUIPMENT:PLAN FOR EQUIPMENT PLAN SEE: L-! F-FF F-FTF F ©© F-H-F-F-F L MAGYS CI L. L. SEARS w 4 �® �— , WA SQUARE 4 [1-7.11\ — MALL g 4 IIIrL 4 _ 1 J 9585 SW WASHINGTON SQ.RD. o _ _ ��— L PORTLAND,OR 97216 ODE — U 4 — NEW TNATIONE:NODESOIZA, DESIGNATION: FORNSEEZA, IN-BUILDING M L_ EQUIPMENT PLAN SEE: IX NEW T-MOBILE NODE AREA.NODE All Ali OEUIPMENON:PNSEE: FOR I-r� 1 �® ri p EQUIPMENT PLAN SEE: E ©� I I NEWT-MO BILE NODEAA.FOR E EJ WV VP L DESIGNATION:P026012A,FOR >..1.... \ / - EQUIPMENT PLAN SEE: z l I1 O I TV VI, L w o a NORDSTROM U M x 1 _ ri LNRISOICIKN APPROVAL STAMP OEPARTAEIIT Fpi L4YD IRE DEPARTMENT FOR SOLOING 6 CONSTRUCTnry M a — SHEET TITLE \ ..........,•\__ r ELECTRICAL SITE PLAN -p% SHEET NUMBER U0 •.�J w 60' 0 30. 60. KALE: 1-=60'-0'12HxD6) E-2 ELECTRICAL SITE PLAN ® (OR) 1,??'= -0-D1x17) 1 VOLTAGE 12012403O4W.200A 42 AIL CA: 1 MAIN CB. 3P/200A PANEL 'LA' LOCATION IN EQUIPMENT ROOM BUS: 200A cIT CKT BKR DESCRIPTION LOAD PER PHASE DESCRIPTION CKTSKR NO AMPS POLES Cl L2 L3 LCL Cl L2 L3 AMPS POLES XO LANDLORD SIGNATURE 1 20 I EXIT LIGHT 50 . - - - - SURGE 3 3D 2 SUPPRESSOR, 3 20 1 LIGHTING - 250 - - - - 5 20 1 GPI - - 180 - - - - - - 8 // 7 20 1 RECEPTACLES 720 - - 3840 - - TMO 2 40 8 "I EXISTING EQUIPMENT ROOM 1 f 9 SPACE - 840 - - - 11 12 Ns- -_ / , 13 SPACE 14 T'0' 15 10 NEW 1-MOBILE LEASE AREA a • 5 III; NEWT-MOBILE I9"RACK(ALL NEW ROUTERS 19 20 ARE Acil110 UNDER PIE DIRECTION GFALIC800Il IT B R VIOLATNNYOF LAW FOR ANY PERSON,UNLESS THEY AND ACIDC CONVERTER TO 8E MOUNTED 22 PROFESSIONIL rOGBEFA.To u TtO THIS DOCUMex1. cENSED I INSIDE RACK) 21 a ' W20 T Mobile® 24 N - �- -II H I I ■ ■ ■■ ■ �I III II II I NEW TAROOILE FIBER ROUTE FROM EXISTING 27 28 -J TELCO ROOM TO FLEX!ZONE MICRO AND FLEX!LITE ANTENNA LOCATIONS. ATC TO 29 30 / FUTURE I FUTURE I ( I I RUN POWER B FIBER FROM HEAD END ROOM 8960 ALDERWOOD ROAD CARRIER CARRIER 3 1 i TO SMALL CELL.ATC TO BRING 200 AMP 31 32 PORTLAND,OR 97220 O 10'x]' 1O'x3' i I W SERVICE TO HEAD END SPACE.NEW 2'B 33 34 ,,,IL CARRIER CARRIER CONDUITS WITH POWER AND FIBER ROUTE O , EQUIPMENT OUIPMEN tt AREA AREA y MOUNTED TO EXISTING CEILING,TOTAL 35 38 "I rl 4 DISTANCE TO BE VERIFIED BY CONTRACTOR. • /I�� FUTURE FUTURE , w ® 37 38 Technology llssociates 39 4O "a wNI 1IPM I PNW MARKET OFFICE EQUIPMENT FIPMEN 41 42 AREA AREA . 7117 SW BEVELAND STREET, w. . TOTAL 770 250 180 5500 5808 0 TOTAL SUITE 101 w f T -7TOTAL CONNECTED LOADS:8,888 VA TIGARD,OR 96006 I II I I b .1 _y_,L +1_i_I_",_ _-_1•1 4 TOTAL AMPG'.4M 1N.0T ALL EQUIPMENT(FUSES,CIRCUIT BREAKERS,BUSSING,ETC.)SHALL HAVE A SHORT CIRCUIT RATING EQUAL TO, TeChnOlOgyAssOCiateS w OR GREATER THAN,THE AVAILABLE SHORT CIRCUIT CURRENT AT THE LOCATION. ARCHITECTURE&ENGINEERING -- L _ L _ ' EXISTING OVERHEAD CABLE LADDER 2. ALL ELECTRICAL EQUIPMENT SHALL BE U.L.LISTED. II 2851 GAMING DEL RIO SOUTH,SEE.200 II EXISTING X S VIGT-M PANEL A EL2WER aov,30. TO 2N00 3. ALL ELECTRICAL EQUIPMENT EXPOSED TO THE WEATHER SHALL BE LISTED FOR EXTERIOR USE. SAN DIEGO,CA 92108 T-MOBILE I9"RACK 4. SQUARE"0"NOOD PANELBOARD ■ EXISTING FUSED DISCONNECT SWITCH 5. CU-2 SHALL OPERATE ONLY IF CU-1 IS DISCONNECTED FROM POWER BY AUTOMATIC CONTROLS. 6- MULTIPLE CIRCUITS NEED COMMON"OFF"HANDLE CUPS. 4 ,..,/,..,/.,,,/,,,,,,,/,/,///,/////,/,,,///„//,/,///,/,/,/// PANEL SCHEDULE SCALE 3 41�RBI, ATCCOMMENTS MGM &SHEETS EL SN N.T.S. I mrsv9n NEW RFDDMGRN.I mos. // EXISTING PANEL"LA"120V/240V.3 PHASE,4W,200A 9 1NIAT0IT ISSUED FOKImKCD REVIEW MGM v 4 I t EXISTING TELCO BOARD A mm�RB17 LsuED FOR eOxcD RENEW MGM �INSETNEWR 4AMPBE SERVICENEXISTING .—NE TEVTW.TH]-pAWOH1-#IDAWO REV DATE DESCRIPTION BY EXISTING STAIRS 7 U. (TYE) POYH024A w a ��• ::_=: WA SQUARE OX I I MALL p 4 l • W B ( III a 9585 SW WASHINGTON SQ.RD. I PORTLAND,OR 97216 p �1 EXISTING EXISTINGrP // SWITCH GEAR SWITCH GEAR to r�t1 IN-BUILDING 4: it/ l Q "---'/ �' p _I p w NEW T-M INLE MV(FIBERGTIL O ROOM III K LOCATED EXISTNO TELCO ROOM / NEW T-MOBLE EQUIPMENT RACK IMIIIII1 M F - joi larEn� W -�� NOTE , f _ ��,`�I I i n L_j_j_j_j-j- AWN I.UNLESS NOTED OTHERWISE,ALL CONDUITS J TO BE INSTALLED TD BE EMT FOR W DOOR I ���1�� I�1�� rl �! AND RIDGED FOR OUTDOOR.UNLESS NOT N I L //////////l/.%/////////////////// illUfOl//////per ALLOWED BY ELEC CODE. 11 x I: 1 JURISDICTION APPROVAL STAMP 2.ALL ELECTRICAL CONDUCTORS TO BE ■ ■ ' DEPARTMENT FOR LAND USE o APPROPRIATELY SIZED AND TO DEEMTIEXTFOR BUILDING 8 CONSTRUCTION az BE INSTALLED s UNLESSOTHERWISE NOTED. cc. L SHEET TITLE GROUNDING DIAGRAM AND = UTILITY POINTS OF SERVICE AND WORK!MATERIALS SHOWN ARE BASED UPON PRELIMINARY INFORMATION PROVIDED BY THE SITE WALK.PRIOR TO START NOTES II OF CONSTRUCTION CONTRACTOR TO OBTAIN CURRENT UTILITY PLAN. 4 CONTRACTOR SHALL COORDINATE WITH UTILITY COMPANY FOR FINAL AND EXACT WORK,MATERIALS REQUIREMENTS AND CONSTRUCT TO UTILITY SHEET NUMBER .)I ® COMPANY ENGINEERING PLANS AND SPECIFICATIONS ONLY.CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT.PULL ROPES.CABLES,PULL BOXES, VIA CONCRETE ENCASEMENT OF CONDUIT(IF REQUIRED).TRANSFORMER PAD,BARRIERS,POLE RISERS,TRENCHING,BACKF LL.PAY Al L UTILITY COMPANY FEES PAD INCLUDE ALL REQUIREMENTS IN SCOPE OF WORK x 111 E.3 EQUIPMENT ELECTRICAL PLAN N.T.S.CE 2 ONE LINE DIAGRAM N.T.S.AE 3 ' ELECTRICAL GROUNDING SPECIFICATIONS 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE CURRENTLY IN EFFECT FOR THE AUTHORITY HAVING LANDLORD SIGNATURE JURISDICTION. 2. ALL GROUNDING DEVICES SHALL BEUL.LISTED FOR THEIR INTENDED USE. S. GROUND WIRES SHALL BE TINNED K2 Awe BARE SOLID COPPER UNLESS OTHERWISE NOTED. 4. CONFECTIONS OF ALL GROUND WIRES TO THE GROUND RING SHALL BE EXOTHERMIC (CAD-WELDED),UNLESS OTHERWISE NOTED.AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS AND T-MOBILE WIRELESS BROADBAND STANDARDS. /���f�������������������������������������f����������������f����������������ll�� RlsREATIIG NFuwwR,ECTMOFLICETBER 6. GROUNDING CONDUCTORS SHALL BE ROUTED IsARE',VIOLATIOL OF LAT FOR NIT PERSON.UUuuS S THEY ALONG THE TEST AND T POSSIBLE WHEN NREQUIRED.G O ND LEADS CONNECTION/ CONN NEW ECTIONN(TIP.)ICAL UG ' SHALL BE BENT TO A MINIMUM OF 8'RADIUS. © T •■•Mobile®• 6. WHERE GROUND WIRES ARE ROUTED FROM ANY `� i CONNECTION ABOVE GRADE TO THE GROUND RING. ', INSTALL WIRE IN 3M'HEAW WALL LIQUID TIGHT r 7 r FLEXIBLE CONDUIT FROM CONNECTION POINT TO 5" BELOW GRADE AND SEAL THE TOP WITH SILICONE / i I V SEALANT. 8960 ALDERWOOD ROAD _____ PORTLAND,OR 97220 T. ALL SECTOR GROUND BARS 2',COLSLLLECTOR AND MGB BARS 4'BE TINNED,1/4" ER. -j I /� NEW MOAWG FROM RACK OOF FOUI IICITH TO CONNECTIONS WITHOUTACCOMMODATE DOUBLING ALL j _ I C TQGRdINO BAR(TYP.) 0-6-G-6-G • iN �RAAA LUGS,AND EACH INSTALLED WITH ISOLATORS. /' 1 \ ® Technologyitnssociates WHEN CONNECTING GROUND BARS(WITHIN 10 - I, T "" 1I T i'I 7' WT-T 1Iry 0 • FEET OF GRADE)DIRECTLY TO THE GROUND RING, PNW MARKET OFFICE 2 EA 02 SOLID DOWNLEADS SHALL BE CAD-WELDED -- I 1 I I! 11 II I NEW GROUND BAR(FIELD I. °p 7117 SW BEVELAND STREET, TO THE GROUND BAR,I AT EACH OPPOSITE I II II I II I :1 I, II II I I je VERIFY LOQATIONHTYP) SUITE 101 BOTTOM CORNER.AND EACH SHALL RUN IN 3I4' �_ _1_1_J�_11_J_J__1_1_JL__.. HEAVY WALL LIQUID TIGHT FLEXIBLE CONDUIT }m NEW F6 BAG FROM FLEXI ZONE TIGARD,OR 98006 FROM GROUND BAR DOWN TO THE GROUND RING. % I w ® I. MICRO(FINIS S FWFA);ROUTE LEAD WHEN CONNECTING SECTOR GROUND BARS, TO NE IN CROON 0 RAR DAISY-CHAIN THE GROUND BARS AND RUN I EA.P2 E ® ss c AWO STRANDED FROM THE MIDDLE GWITH ROUND WN f I ® Technolo AsSociateS INSULATION FROM THE MIDDLE GROUND BAR TO -- .- w w 9y THE GROUND RING ANDCAO•WELD TO THE RING. I �G—G-G—G • H. ARCHITECTURE&ENGINEERING 8. WHEN ATTACHING STRANDED GROUND LEADS TO I 2851 GAMING DEL RIO SOUTH.STE.200 THE GROUND BARS.2 HOLE COMPRESSION LUGS j- — -H- -I F- — — SHALL BE USED,PROTECT WTH WEATHERPROOF w i SAN DIEGO,CA 92108 HEAT SHRIEK,AND WITH A THIN COAT OF T(OPR ISHIELD'OR EQUIVALENT PROPERLY APPLIED AND I v HARDWARE.ONLY WITH STAINLESS STEEL _:.-:::'::.� I I u ! it. I NEW N6AWG FROM FLEXI LITE BTS I DInw1I1E ATC COMMENTS MGM 9. WHEN GROUNDING EQUIPMENT ENCLOSURES. j====8 I I F== (FOFgI;ROUTE LEAD TO NEW 2 no];lOt6 REVISED ESXEETB EL PANELS.FRAMES,AND OTHER METAL APPARATUS. 1 GROUND BAR I OARYMtT NEW RF a+cRAM A 06 AWO STRANDED COPPER WIRE WITH THWN �. I c= MA w yMGM HOLE C ION SHALL BE ATTACHED UTILIZING A 2 H I I U C-2 0 00204017 ISSUED FOR 1B01LCD REVIEW MGM HOLE COMPRESSION TYPE LUG,AND CORROSION WITH '��' �(' ?� , T ,r T n -j'- TI WEATHERPROOF MEATA CLEAN AND CORROSION � T III ii it II 'i II I' II I � I A OBV1aon ISSUED FOR RBUD REVIEW MGM FREE METALLIC SURFACE UTILIZING STAINLESS ( ;I I I I I I I I I -i- STEEL9ELFTA➢%NG SCREWS AS NOTED IN NOTE I 1 it I !i w�G G-G-G • 10 BELOW f-. -t-�L-1_ll_J _Il__1__L_l_1_A_1IT1 HEN DATE DESCRIPTION 3v PREPARE ALL BONDING SURFACES EOR GOUND I W CAND ONNECTIONS BY REMOVING ANY AND ALL PANT --1 II II 1CAD-WELDEDCON ECTIONSTONON-COPPER f I POYHO24A w SURFACES,APPLY ONE COAT OF ANY I IIS ANT-OXIDIZING PANT.'COLD GALV OR w w EQUVALENT. _} J L _ _ -J L WA SQUARE X 11. GROUND ROOS SHALL SE COPPER.CLAD STEEL ' Oo 515UIO',SPACEDNOLESSTHAJIS.ONCENTER. % ,. MALL 4. ALL CONDUITUND S SECURED UTILIZING 9585 SW WASHINGTON SQ.RD. CONDUITS SHALL BE SECUR W UTILIZING ONLY oCLLAMPS.BLRACKIC.ET.ANDORS PPORTS-CONDUCTIVE,UV��D ` PORTLAND,OR 97216 WHEN D.THE CTOR SHALL c /9, EWGROGE ORMRE SYSTEM I IS pRVICES OF�ONOGAMEGGERTH OF E % ��// / L. NDEPENDENT IN-BUILDING 5(OHMS).A COPY OF THE COMPLETE TESTING OR LESS THAN .4' ��zz... ///////l//l�l/l////f/////////�////�//////,�////�/// D REPORT SHALL BE PROVIDED TO THE T-MOBILE I w REPRESENTATIVE. 14. ALL MATERIALS AND HARDWARE SHALL BR / LE INSTALLED IN A WORKMAN.UKE MANNER IN � - m ACCORDANCE WITH MANUFACTURERS i O RECOMMENDATIONS,AND DEFINED IN NFPA-TO AND L. FF APPROVED BYA.H,J, C U It. n LEGEND • EXOTHERMIC CONNECTION JI L STAlc DEPARTMENT FOR LAND USE • MECHANICAL CONNECTION L. DEPARTMENT FOR BUILDING I CONBTRucnx z F-4'...9 EQUIPMENT GROUND BAR SHEET n row.I ANTENNA GROUND BAR(AS REQUIRED) • 4- P2 AWG GROUND LEAD(AS REQUIRED) GROUNDING PLANS U n NOTE. m itv T CONTRACTOR TO REPLACE ALL MISSING GROUND BARS / SHEET NUMBER Q I AND GROUNDING CONNECTIONS AS REQUIRED. `.I.� 0 G. 1 o SCALE SCALE SCALE = NOTES & LEGEND N.T.S. 1 EQUIPMENT GROUNDING N.T.S. 2 ANTENNA GROUNDING - TYPICAL OF ALL NODES N.T.S. I 3 NOTES'. 1. PROVIDE NO-OX GREASE AT CONTACT `,` EXISTING YB AWG NEW RACK GROUNDING KIT:NB AWG 'ail .Ti I WIRES TO EXISTINGG EQUIPMENT T STRANDED Cu WIRE WITH GREEN,BODY, '�\ 1 SURFACE BETWEEN LUG AND GROUND BAR i THWN INSULATION OR BLACK ^ 2. CONTRACTOR WILL VERIFY BUSS BAR 011 GROUNDING TO THE TOWER OR RING. -- — — TYPE HS TYPE 2-YA-2 TYPE XA TYPE YA-2 TYPE GT _ 3. GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC jvivls -1 _ CONNECTION. 0 0 O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O EXISTING MAIN GROUND BAR TYPE TA TYPEVN TYPE NC TYPE SS TYPE GY O 00000000000000000000 0 0 • 00 00 0 00 0 O O O O 0 O VVrtipl.i. ;NT Ir ErtEMcnro uwEnwNERDmAEcrnlBio nucEM 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ' i MDESS L,UMEEkIVPLIENIM6o UMNT —J i \_J\_ TYPE VV TYPE VS TYPE VB ME PT TYPE OR 1 TWO-HOLE LUG,BOLTED TO T■ ••Mobil EXOTHERMIC WELD e®• GROUND BAR USING 3/8'-16 x 1 NOTE: 1/4-STAINLESS STEEL HEX UNIT �EXISTI NG(2)N2 AWG SOLID TINNED BARE Cu WIRE ' BOLTS AND HARDWARE. TO EXISTING GROUND RING ERGO EXOTHERMIC MOLD TYPES-SHOWN HERE ARE EXAMPLES CONSULT WITH PROJECT MANAGER FOR SPECIFIC MOLDS TO BE USED FOR THIS PROJECT. 8960 ALDERWOOD ROAD PORTLAND,OR 97220 SCALE SCALE SCALE Technology` Associates NOT USED N.T.S. 10 MAIN GROUND BAR N.T.S. 4 EXOTHERMIC WELDING N.T.S. 1 PNW MARKET OFFICE 7117 SW BEVELAND STREET, NOTES: SUITE 101 3' 12-TO 24- 1. ALL HARDWARE BOLTS,NUTS. WEATHERPROOFING f / I LOCK WASHERS SHALL BE TIGARD,OR 98006 KIT(SEE NOTE9) MIN. WIRE SIZE BURNDY LUG BOLT SIZE STAINLESS STEEL.ALL HARDWARE ARE TO BE AS ANTENNA CABLE CONNECTOR pit AWG GREEN INSULATED YMC-2TC98 3/8--IB NC S2 BOLT FOLLOWS.BOLT,FLAT epp��s WASHER GROUND BR, Techaology4® crates #2 AWG SOLID TINNED VM GROUND LUG,FIAT WASHER,C-2TC36 9/B'-IS NC 92 BOLT LOCK WASHER AND NUT. ARCHITECTURE&ENGINEERING ry #2 AWG STRANDED YA20-2TC30 Ur-18 NC S 2 BOLT 2. COPPER SHIELD,ANTIOX,CR 2851 CAMINO DEL RIO SOUTH,STE.200 CABLE GROUND KIT NO-OX OR EQUIVALENT SHALL SAN DIEGO,CA 92108 two AWG STRANDED YA2B-2TC3B 9/8--16 NC 92 BOLT BE PLACE WHERE ALL DISSIMILAR METALS CONNECT. N8 AWG STRANDED Cu WIRE WITH #4/0 AWG STRANDED vg2&2N v2--1e NC 52 BOLT 3, ALL LUGS ARE TO BE GREEN,BDOV,THWN INSULATION OR INSTALLED PER BLACK(GROUNDED TO GROUND BAR) MANUFACTURERS 3 01R00010 ARC COMMENTS MGM PEAT SHRINK SPECIFICATIONS. (CLEAR HEAT SHRINK INDOORB a1nA201S REVISED ESNEETS EL BLACK HEAT SHRINK OUTDOOR) 4. ALL LUGS MUST HAVE I 04rz2rz017 NEW RF CIAGIVAI MGM ANTENNA AND/OR GPS CABLE BURNDY GROUND LUG INSPECTION WINDOWS. CONNECTION (SEE TABLE FOR SIZE 0 W/Arz01) ISSUED FOR IW%CD REVIEW MGM AND MODEL) c'e A WAV101/ RUED FORPo%CD REVIEW MGM BURNDY AROUND IT NUT(TMR) (SEETABLE FOR SIZE REV DATE DESCRIPTION RV NOTES: LOCK WASHER AND MODEL) MP.) BARE WIRE TO BE I 1. DO NOT INSTALL CABLE GROINDKITATA BEND AND ALWAYS FLAT WASHER NOOXAT BOTH ENDS POYHO24A DIRECT GROUND WIRE DOWN TO GROUND BAR. (TYP) 2. GROUNDING KIT TYPE SHALL BE APPROVED BY TMO PRIOR TO INSTALLATION USHALL GROUNDING W TRETKT�CODFSHRINKSHALNOTBOEU9EDTE � ANERPROOFING pROUNDBR CONDUCTOR WA SQUARE FLAT WASHER Ill BOLT,TVP.) MALL 0 w 0 S NOT USED SCALE N.T.S. 11 NOT USED SCALE N.T.S. 8 CABLE GROUNDING SCALE N.T.S. 5 MECHANICAL LUG SIVCALE I 2 9585 SW WASHINGTON SQ.RD. NOTES. PORTLAND, OR 97216 O 1. PROVIDE NoOX GREASE AT CONTACT SURFACE BETWEEN LUG AND GROUND BAR IN-BUILDING U 0 w ¢ 2. CONTRACTOR WILL VERIFY BUSS BR GROUNDING TO THE TOWER I . O 3. GROUND BARS AT BOTTOM OF TOWERS OR MONOPOLES SHALL USE EXOTHERMIC FI 0 CONNECTION. ANTENNA GROUNDING KIT:NB AWG H STRANDED Cu WIRE WITH GREEN, O /OWVJHWN INSULATION OR BLACK O F ~ TWO-HOLE LUG,BOLTED TO GROUND BAR USING 318'-IS x 1 1/4'STAINLESS c - U STEEL HEX UNIT BOLTS a AND HARDWARE. K \/� C. r 0 O Q O 0 0 0 0 O 0 EXISTING 4"x12-x1/4- JURISDICTION DEPARTMENT FOR LAND USE THK.,TINNED DEPARTMENT FOR MURDIND S CONSTRUCTION .2O "f s'fS O O O O Q Q O 0000 O GROUND BAR ON WALL,FLOOR OR ON SHEET TITLE A ANTENNA TOWER 0 0 0 0 0 0 0 0 GROUNDING w EXOTHERMIC WELD DETAILS U 10 ED iR —�BAREICu WIRE TO EXISTINNG ft2 AWG SOLID G TOWER SHEET NUMBER u 0 ¢ GROUND BA IN A NOT USED SCALE 12 NOT USED SCALE 9 NOT USED SCALE 6 SECTOR GROUND BAR SCALE . . G-2 N.T.S. N.T.S. N.T.S. N.T.S.