Plans 2 a delK- CorAJ2,f / - 2 fM 3)ri f.za - 1 roP ✓
s � � � �-
aoI
$ L,
x
2�,
-0 { 1 �/ \ ?f 4
r i A t _ r i 9 7t #`_ y y ,R^ y A Ti
Ili
iiiWie
p #P,
v
R
SSS
.
Iran n
/•
> ,fir.
. ,P
OFFICE COPY RECEIVED
VALIDITY OF PERT• IT CITY 7F TTGARD
P r jIT ViI It Ls� 1-(''t CODECU,tiII'I.I:�NCE
MAR 1 2 ZOZO
THE ISSUANCE OF A
BASED Oi\I CONST`tuC r,H'R
ON A�i',3 o�`Cd j CITY OP TIGARD
DOCUMENTS AND OT
DATA SHALL.NOT PREVENT O.1 C: i 1 BUILDING DIVISION
THE CODE OFFICIAL FROM
REQUIRING THE Permit #: aU o1.Qag. .
OF BRROPS.
OSSC 105.4CORRECTION
Address: j i 1, �< S `� C .- 0 . H Syr y
Suite#:By: Date: vie
s
A/1
RECEIVED JANUARY 2018
insite.
MAR l 2 Z020 ® JamesHardie
Building design.Streamlined.
CITY OF TIGARD
BUILDING DIVISION
HardiePlank® Lap Siding Submittal Form 41
Submitted to: HZ5®Product Zone HZ1 O®Product Zone
Project Name' Product Width: 5-1/4in 6-1/4in 7-1/4in an 8-1/41n 9-1/4in 12in
Submitted by' Product Finish: Primed ColorPlus®Technology
Product Texture: Smooth Select Cedarmill® Colonial Roughsawn®
Date' Colonial Smooth® Rustic Cedar
DIVISION:07 00 00 THERMAL AND MOISTURE PROTECTION SECTION:07 46 46 FIBRE CEMENT SIDING
HARDIEPLANK® LAP SIDING Available Sizes
Manufacturer Product Width(in) Length Thickness(in)
James Hardie Building Products, Inc HardiePlank lap siding* 5-1/4, 6-1/4, 12 teat 5/15
The products are manufactured at the following locations,with quality 7-1/4,8,8-1/4,
control inspections by ICC-ES: 9-1/4, 12
• Cleburne,Texas • Peru,Illinois "HZ5:9-1/4, 12 only available primed HZ10:5-1/4,9-1/4, 12 only available primed.
• Plant City,Florida • Pulaski,Virginia
• Reno,Nevada • Tacoma,Washington
• Waxahachie,Texas • Fontana,California Texture&Finish
HardiePlank lap siding comes in a variety of textures and finishes.The product
is available in smooth or wood grain texture.Additional textures are available
Compliance with the following codes on a regional basis.Finish options are primed for field paint,or factory
• 2012,2009 and 2006 International Building Code®(IBC) finished with ColorPlus®Technology.Color availability varies by region.
• 2012,2009 and 2006 International Residential Code®(IRC)
Engineered for Climate®
Features HardiePlank lap siding is engineered for performance to specific weather
conditions by climate zones as identified by the following map.
• Noncombustible • Weather Resistant-Engineered for Climate®
• Dimensionally Stable • Impact resistant
• Resists damage from pests • Sustainable
Use
James Hardie fiber-cement lap siding is used as exterior wall covering.
The product complies with IBC Section 1404.10 and IRC Section R703.10.
The product may be used on exterior walls of buildings of Type I,II,III and IV
construction(IBC) yZ
s �
Description 1 A xg
HardiePlank lap siding is a single-faced,cellulose fiber-reinforced cement .t r+ t4
a
(fiber-cement)product. HardiePlank lap siding complies with ASTM C1186,
as Grade II,Type A;has a flame-spread index of 0 and a smoke-developed
index of 5 when tested in accordance with ASTM E84;and is classified as
noncombustible when tested in accordance with ASTM E136,
SPECIFICATION SHEET 01 JANUARY 2018
Performance Properties
General Property Test Method Unit or Characteristic Requirement Result
_e-latn ±0.5%or t 1/4 in
W Width i 0.5%or±1/4 in
5 Dimensional Tolerances ASTM C1185 Thickness ±0.04 in Pass
m Squareness <1/32 in/ft of length
Q Edge Straightness <1/32 in/ft of length
Q Density,Ib/ft" ASTM C1185 As reported 83
o Water Absorption,%by mass ASTM C1185 As reported 36
i Water Tightness ASTM C1185 Physical Observations No drop formation Pass
o_ Wet conditioned,psi >1015 psi
Flexural Strength ASTM C1185 Pass
Equilibrium conditioned,psi >1450 psi
.J Thermal Conductivity (BTU/(hr-ft°F))/inch 2.07
a
2 Actual Thermal Conductivity (K� 6.62
cc ASTM C177 As reported
= Thermal Resistance R=1/Keff 0.48
I- Actual Thermal Resistance (R) 0.15
Warm Water Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass
_ Heat/Rain Resistance ASTM C1185 Physical Observations No visible cracks or structural alteration Pass Pa
—'m Physical Observations No visible cracks or structural alteration
g Freeze/Thaw Resistance ASTM C1185 Mass Loss,% <3.0% Pass
p Freeze/Thaw,%strength retention >80%
UV Accelerated Weathering Test ASTM G23 Physical Observations No cracking,checking,or crazing Pass
Flame Spread Index(FSI) 0
U Surface Burning Characteristics ASTM E84 Smoke Developed Index(SDI) <5
Fuel Contributed 0
w NFPA Class A
cc t'i 8 Uniform Building Code Class As reported 1
International Building Code®class A
U Noncombustibility ASTM E136 Noncombustible Pass/fail • Pass
Fire Resistance Rated Construction ASTM E119 Fire Resistance Rating 1-hour Note 1
Note 1:listed on Wamock Hersey and ESR 2290
Installation Sustainable Design Contribution
Install HardiePlank lap siding in accordance with: • Regionally sourced content-varies by project location
• HardiePlank lap siding installation instructions • Avoidance of certain chemicals or Red List Compliance
• ICC-ES ESR 2290 Detailed product information for LEED projects,or other state or regional
• Requirements of authorities having jursidiction sustainability programs is available through James Hardie Technical Services.
Warranty Storage and Handling
HardiePlank lap siding:30-year,Non-Prorated,Limited Warranty Store flat and keep dry and covered prior to installation.
ColorPlus Technology: 15-year Limited Finish Warranty
Technical Services
Contact James Hardie Technical Services online at JamesHardie.com,
or by phone at(800)426-4051
P2
IMPORTANT:Failure to install and finish this product in accordance with applicable building codes and
James Hardie written application instructions may affect system performance,violate local building
a mesHardie codes,void the product-only warranty and lead to personal injury.
•
DESIGN ADVICE:Any information or assistance provided by James Hardie in relation to specific projects
must be approved by the relevant specialists engaged for the project eg.builder,architect or engineer.
Additional Installation Information,Warranties, James Hardie will not be responsible in connection with any such information or assistance.
and Warning are available at JamesHardie.com
®2018 James Hardie Building Products Inc.All rights reserved.TM,SM,and®
denote trademarks or registered trademarks of James Hardie Technology Limited. '
1 866 442 7343 I www.jameshardie.com The International Building Code and International Residential Code trademarks are registered trademarks
of International Code Council.Inc.TB1001 07/14