Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (5)
tv 2020 -a0226, iOzoio sal 6a2g RD Job Name: Tag# ;'.. Submittal Data Sheet FTKI8NMVJU I RKI8NMVJU 1.5-Ton Wall Mounted Cooling Only System t�fii� ( ag t ,ii itix t t si ii _e !( E l`Y E Efficiency Coating ,21 APR 1 b 2020 SEER 18 awrag � .. _ — .. CITY Of'T.'GARD EER 12.5 * J ,1 tiLDING DIVISION _.. .: '1��1 = `_� = ! Performance r:� .. -_ _ _ — Coaling(Btu/hr) --"—�=#' Rated(Min/Max) 18,000{5,500/20,000) J 1,/J J 1` ;�- -.. - . i j, , r)rj.r. `i' ... Sensible @ AHRI 14,480 — L. — Moisture Removal gal/h 1.0 - Standard Operating Range 5Q°F—115`F Complete warranty details available from your local dealer or at Extended Operating Range" -4 -� 15°F www.daikincomfort.com.To receive the 12-Year Parts Limited Rated Cooling Conditions: Indoor:80°F DB/67°F WB Warranty,online registration must be completed within 60 days of Outdoor:95°F DB/75°F WB installation.Online registration is not required in California or Quebec. *With field settings and wind baffle If product is installed in a commercial application,limited warranty period is 5 years. Electrical Indoor Specifications 208/60/1 230/60/1 Cooling System MCA 18.3 18.3 H ? M System MFA 20 20 Airflow Rate(cfm) 713 579 Compressor RLA 10.0 10.0 L SL Outdoor fan motor FLA .45 .45 448 403 Outdoor fan motor W 69 69 Sound(dBA) 49/44/38/33 Indoor fan motor FLA .30 .30 H/M/L/SL Indoor fan motor 46 46 Dimensions(H x W x D)(in) 11-5/8 x 39 x 10-3/8 MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A) Weight(Lbs) 27 RLA:Rated load amps(A) W:Fan motor rated output(W) Outdoor Specifications Compressor Hermetically Sealed Swing Type Piping Refrigerant R-410A Liquid (in) 1/4 Factory Charge(Lbs) 2.49 Gas(in) 1/2 Refrigerant Oil PVE(FVCSOK) Drain (in) 5/8 lirtz,Cooling Max. Interunit Piping Length (ft) 98.4 Airflow Rate(cfm) H 2,461 Max. Interunit Height Difference (ft) 65.625 Chargeless(ft) 32.8 SL 2,108 Additional Charge of Refrigerant(oz/ft) .21 Sound Pressure Level(dBA) 54 Dimensions(H x W x D) (in) 28-15/16 x 34-1/4 x 12-5/8 Weight(Lbs) 97 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date:September 2018 Page 1 of 4 a s 0 3 ry rdia w A a a t VI awleg THE MARK(->)SHOWS PIPING DIRECTION kLI a'AIR FLOW(INDOOR) ._ 111111 REAR 39(990mm) o fiafaiia .--" n�iaioiiiii�iiiaii�1 4 U LEFT �■■■■■■■ RIGHT �� j E w0= c .;:. .------i,>: (INCLUDING A a¢ m m ���=���I♦III MOUNTING PLATE % % ,o rn a o c 10.7/16(265mm) / 5� G ; n o 70-3J8(263mm) 1.16/16(50mm)MIN 0 ( 1-15/16(50mm)MIN c u —' REQUIRED SPACE o a E �-. GENERAL RATING MAINTENANCE) (SPACE FOR in e NAME PLATE MAINTENANCE) 'o e TERMINAL BLOCK -" _ m o ;, ': m WITH EARTH it o a N r TERMINAL Yto E' __—�. \" (INSIDE) a G ' o BOTTOM FRONT GRILLE FIXING SCREWS 1 I UP AND DOWN WIND DIRECTION ^ •� - c (INSIDE) CONTROL BLADE MOVABLE RANGE -'� �` L - n O. m FLAPS ABOUTI5-3/414WITu1t DRAIN HOSE ,� GAS PIPE 0112.(Q12.7mm)CUT v GAS PIPE m E u r ABOUT 17-5/16(440mm) LIQUID PIPE �^ o .5 �` .. SIGNAL RECEIVER I =OUT 18-1/8 060mm) = !}� OPERATION LAMP in m-c ' b TIMER LAMP U c '= (Z , INDOOR UNIT ON/OFF SWITCH DRAIN HOSE ��` ���� 3 GI ROOM TEMP.THERMISTOR (CONNECTING PART LIQUID PIPE$1/4(06.4mm)CUT _ o m I.D. 59/16(4514mm) ABOUT 14-3/16(380mm) a a (INSIDE) u MODEL NAME PLATE O.D.0.5/8(516mm) ABOUT 143/8(365mm) < Si .o CZ ABOUT 17-3/4(450mm) f c c CD--SIGNAL TRANSMII IIR E Y C /BLADE ANGLES o Z O 1-7/8(48mm) _13N6(20mm) UP/DOWN(AUTOMATIC) C 38(990mm) = o m 29-3/8(746mm) 5(126.5mm) c '^ Cl) COALING,DRY FAN o ,`, N111 IE E v O 30� 5 I 55' 70' 85' 80' - -' __— _—__--- 00 I WALL HOLE FOR EMBEDDED PIPING N RIGHT/LEFT(MANUAL) 1-Tl8(48mm) U3-1J8(o80mm)HOLE 2-3/8(60mm) WALL HOLE o `w 03-Ile(080mm)HOLE o n STANDARD LOCATIONS OF WALL HOLES E, WIRELESS REMOTE CONTROLLER \ as•q; / a 2 (ARc460A9) 3D091781 n N Z I I CCI I1 6L N O 7, v N Zion..._ o a P HANDLE 9/16(14) 34-1/4(870) 2-3/4(70) ro _ ELECTRIC WIRE INTAKE 1/4IlIlt (7) 12-5/8(320) 1-3116(30) BRAND NAME PLATE OUTDOOR AIR THERMISTOR Y c ImiMANUFACTURER'SLABEL I 111• LI ' g —IM ..Ili Ve iarkt N fT WWI MfiI c II 141 rr 9116(14.5) 7/8(23) a) v p 4-HOLES FOR FOUNDATION BOLTS 'r' c (M8 OR M10) 23.5/B(600) I _ 4.15116(125) 13-5/8(346) 7/16(11) o. 0. fO (INSTALLATION LEG LL ,E, c 'a. ", PITCH) .`o E 1', I O '1' Ii. 14.1/2(368) ti ° }, m 0 g 'n 9°u n 0 I O ' I' WALL HEIGHT ON AIR OUTLET SIDE ro m CO GROUND TERMINAL ^ ( e=1m 1 MINIMUM SPACE FOR AIR PASSAGE -LESS THAN 47-1/4(1200) Y 3 - WI _ ,: occo 0 Y `w 2 0 :���.: LIQUID E N 5' 1 k 20-11/16(525) 7 riirisirnirrrilvriiivvi +' STOP VALVE / ! t _ (01/4(o6.4)CuT) DRAIN OUTLET y QI LCONNECTION WJOINT) ¢ a CuT c y a .N p 1-15/16(50) 1 m 1.15/16(50) v 1-15/16(50) w SERVICE = ( n M AS 8. CD PORT CO r fi E r'l a} 1p .._.._. viiirrrvrrrrovriiiilviiir II CS ol 0 co A., N CI IIIII,If I liJi;4dII ---i D {}. UNIT:inch(mm) ° v 6-13/16(173) IN CASE OF REMOVING C:3D092224 v :s ` STOP VALVE COVER AND `^ /� TERMINAL STRIP COVER 2 ili a Z t c 0 CO 0 a v 7, a 1— -C N V IyO s 11 E I7J .0 En ,t ri a 4 s • BRC944B2E-A08 —Wired Remote Controller Kit Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing #: MODEL COMPATIBILITY: Compatible with Single Zone/Multi Zone/SkyAir system indoor unit models: • FTXS, CTXS, CTXG, FTXG, FDXS, CDXS, FVXS • FTX, FTXN, FTK, and FTKN with the use of an Interface adaptor KRP067A41 E/KRP980B1/KRP980B2E (sold separately): Indoor Unit Models Interface Adaptor Part Number FTX09NMVJU, FTX12NMVJU, FTKO9NMVJU, FTK12NMVJU, KRP067A41E FTXN09NMVJU, FTXN12NMVJU, FTKNO9NMVJU, FTKN12NMVJU FTXN_KEVJU KRP980B1 FTX15NMVJU, FTX18NMVJU, FTX24NMVJU, FTK18NMVJU, FTK24NMVJU, FTXN18NMVJU, FTXN24NMVJU, FTKN18NMVJU, KRP980B2E FTKN24NMVJU SPECIFICATIONS: PRODUCT IMAGE: Model BRC944B2E-A08 Description Wired Remote Controller Kit 0 Maximum Indoor Units 1 Total Wiring Length 26ft (8m) 4.75 in x 4.75 in x 0.69 in � � ' Dimensions (120mm x 120mm x 17.5 mm) gy Communication ` Protocol S21 j �, - s, t� Comfort Setpoint Range 64°F—90°F Set Point Range I'll= Start/Stop ill Mode (Auto/Heat/Cool/Dry) BRC944B2E(A remote controller adaptor is included) Operation Set Temperature Setpoint Fan Speed Airflow Direction One-time Timer BRCW901A08 Scheduling Daily Timer FEATURES: • The Wired Remote Controller kit includes a Wired Remote Controller(BRC944B2E)and a wired remote controller cable (BRCW901A08) Daikin North America LLC,5151 San Felipe,Suite 500, Houston TX,77056 www.daikinac.com www.daikincitv.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Page 1 of 2 BRC944B2E-A08 - Wired Remote Controller Kit Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing#: • Selectable auto/cool /heat/dry operation modes with adjustable setpoint and fan speed • Set temperature setpoint in °F or°C units with 1 degree increments • Temperature is controlled through indoor unit temperature sensor • Built in one time or daily timer functionality with up to 2 timer actions per day • Approximately two hour battery backup • Can be used together with the factory supplied standard wireless remote controller DIMENSIONS: 4-1/4 - N V n CORD our ETt£ u 11/16 7/8 1-1/8 11/16 1-1 /18 L DOCUMENTATION: Documentation available on www.daikincitv.com and/or www.daikinac.com: • Submittal • Installation Manual • Operation Manual Daikin North America LLC,5151 San Felipe,Suite 500, Houston TX, 77056 www.daikinac.com www.daikincitv.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Page 2 of 2 LI KRP067A41E/KRP980B1/KRP980B2E Interface Adaptor for Wired Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing #: MODEL COMPATIBILITY: Part Number Compatible Indoor Unit Models KRP067A41E FTX09NMVJU, FTX12NMVJU, FTKO9NMVJU, FTK12NMVJU, FTXN09NMVJU, FTXN12NMVJU, FTKNO9NMVJU, FTKN12NMVJU KRP980B1 FTXN_KEVJU KRP980B2E FTX18NMVJU, FTX24NMVJU, FTK18NMVJU, FTK24NMVJU, FTXN18NMVJU, FTXN24NMVJU, FTKN18NMVJU, FTKN24NMVJU SPECIFICATIONS: PRODUCT IMAGE: Model KRP067A41 E/KRP980B1/KRP980B2E •a Description Interface Adaptor for Wired Controllers • { Maximum Connections 1 indoor unit *" : • Dimensions 4.25 x 1.88 x 1.30 inches Mounting Inside the indoor unit FEATURES: • Provides a S21 interface for the compatible indoor unit model which does not have a build-in S21 connector • Connects the compatible indoor unit with one of the following controller/adaptor*: o BRC944B2 -Wired Remote Controller o KRP928BB2S - RA Interface Adaptor for Dill-Net o KRP413AB1S -Wiring Adaptor for Timer Clock I Remote Controller o BRP072A43-Wireless LAN Connect Adaptor(includes an Adaptor for Wired Controller already) *Additional cable(BRCW901A08/DACA-BRCW901 P10/DACA-BRCW901 P25)is needed if both BRC94482 and KRP928BB2S are connected. (The Wired Remote Controller Kit BRC944B2-A08 includes both the controller BRC944B2 and the cable BRCW901A08.) WIRING DIAGRAM: • Connects to one controller/adaptor: Daikin North America LLC,5151 San Felipe,Suite 500, Houston TX, 77056 www.daikinac.com www.daikincitv.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without Incurring any obligations) Page 1 of 3 atart. heeAt �t KRP067A41 E/KRP980B 1/KRP980B2E Interface Adaptor for Wired Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing#: Adaptor for --Inside indoor unit Wired Controller S602 TWO Option a 6RC94482/ KRP928882S/ 8RP072A43/ KRP413AB1S 321 1 � i S403 t I € 1 PCB of indoor unit i 4 ! t S 3 • Connects to BRC944B2 and KRP928BB2S together -inside indoor unit Adaptor Adaptorfar Wired uttosoxarm som Controller KRP9288B2S S21 € r :1151i Hit O racy SWii SW2 0 '— LED1 0 ss SWa sate Test Si R S8 SS ®9 Stft2-. ()tbd 0 zt—_� 1 Ft PCB of indoor unit • Additional cable(BRCW901A08/DACA-BRCW901P10/DACA- BRC944B2 BRCW901P25)is needed(The Wired Remote Controller Kit BRC944B2-A08 includes both the controller BRC944B2 and the cable BRCW901A08.) Daikin North America LLC,5151 San Felipe,Suite 500,Houston TX,77056 www.daikinac.com www.daikincity.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Page 2 of 3 KRP067A41 E/KRP980B1/KRP980B2E Interface Adaptor for Wired Controller Project Name: Location: Approval: Engineer: Date: Submitted to: Construction: Submitted by: Unit#: Reference: Drawing#: DOCUMENTATION: Documentation available on www.daikincitv.com and/or www.daikinac.com: • Submittal • Installation Manual Daikin North America LLC,5151 San Felipe,Suite 500, Houston TX,77056 www.daikinac.com www.daikincitv.com (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incuning any obligations) Page 3 of 3 RECEIVED APR 1 b 2.02E AMERICAN HEATING C`TY°F C'G HEAT PUMP ON WOOD PLATFORM BOLDING DIVI,. 2x PLATFORM AT METAL ROOF STRUCTURAL CALCULATIONS ANCHORAGE: Al-A4 SKETCHES: CU2 (6 PAGES TOTAL INCLUDING COVER SHEET) 1Aii/21 �``*y.' NVA �Q ' 7 July 24, 2019 ;�/A U ` PROJECT NUMBER: 190237.01 iyx4 ior `S A`w T i R' if 11 0 ARC HI IEC LURE Ell A ERING 111) PLAT.NtJIN G I N E R 1 0 k% to N DS CAPE 15895 SW 72ND AVE SUITE 200 PORTLAND,OR 97224 PHONE:503.226.1285 FAX:503.226.1670 INFO@CIDAINC.COM W W W.CIDAINC.COM CIDA AMERICAN HEATING STANDARDS RNH TEL: (503) 226-1285 CONDENSER UNIT 7/24/2019 FAX: (503)226 1670 MECHANICAL UNIT ATTACHMENT-LATERAL FORCES HEAT PUMP ON 2x PLATFORM Wp:= 2701b Weight of unit W,:= 1001b Weight of curb Wt:= Wp+ W, Wt=370 lb L:= 34in Length of unit Lc:= 44in Length of Curb wm:= 34in Width of unit w,:= 42in Width of curb hm := 40•in Height of unit h,:= 12•in Height of Platform hmc:= hm + h, hmc= 52 in Total height of unit on Platform SEISMIC PARTS AND PORTIONS (PORTLAND, OR 97227) Mapped Adjusted Maximum Design S Ss:= 1.043 site class= D Sms:= 1.126 Fa:= S ss Fa= 1.08 Sips := 3'Sms SDS =0.751 s SEISMIC PARTS AND PORTIONS (BEAVERTON, OR 97005) Mapped Adjusted Maximum Design Sms 2 Ss := 1.076 she class=D Sms:= 1.151 Fa:_ — Fa= 1.07 SDS:_ —'Sms SDS = 0.767 Ss 3 SEISMIC PARTS AND PORTIONS (VANCOUVER, WA 98663) Mapped Adjusted Maximum Design 2 Ss:= 1.016 site class=D Sms:= 1.107 Fa:= SS ss Fa= 1.09 SDS:= 3'Sms SDS =0.738 S BEAVERTON AREA GOVERNS USE SDS:= 0.85 CONSERVATIVE FOR PORTLAND-VANCOUVER MEINOAREA h := 30ft 1p:= 1.0 ap:= 2.5 RP:= 6 z:= h Air side HVAC component 0.4•ap•SDs•Ip FPun+t:= Rp I + 2•hzl l•Wp F 114.75lb 0.7•F 80.32 lb Punit= Punit= 0.4.ap•Sm.1p z Fp := (I + 2.— •Wt Fp= 157.25 lb 0.7•Fp= 110.07 lb Rp `` hi E:\adcadd119\00000-2019 Mechanical Units10237.01 American Heating Standards 2019\Structural\Heat Pump at Wood Box\METAL DECK\IateraIMECH A2- CIDA ,AMERICAN HEATING STANDARDS RNH TEL: (503)226-1285 CONDENSER UNIT 7/24/2019 FAX: (503)226 1670 WIND LOAD: BASED ON 2012 IBC/2014 OSSC WIND SPEED FOR WASH INGTON COUNTY=120 MPH WIND SPEED FOR CLACKAMAS COUNTY=120 MPH WIND SPEED FOR MULTNOMAH COUNTY=120 MPH WIND SPEED FOR VANCOUVER,WA=135 MPH VANCOUVER,WA GOVERNS V35:= 135 Exposure B Kd:=-0.85 Kh:= 0.7 Kzt:= 1.0 GCr:= 1.9 GCr ven:= 1.5 q1:= 0.00256•Kh•Kn•Kd•V3s2•psf F:= GC qZ F= 52.74 psf Pwind unit F•L•hm Pwind unit=498.14 lb Pwind F.L'hmc Pwind= 647.59 lb WIND LOAD: BASED ON 2012 IBC/ASCE7-10-VERTICAL Fvert qi GCr ven Fvert =41.64 psf Pwind unit vert Fven'L.Wm Pwind unit vert = 334.28 lb 'wind_total_ven Fvert'Lc'we Ptvind total vert= 534.3916 OVERTURNING-UNIT TO PLATFORM LC#7 0.6D+0.6W LC#8 0.6D+0.7E WIND-Overturning at unit to platform SEISMIC-Overturning at unit to platform him /hml Mot_wind unit_H -= Pwind unit'2 Mot,,.seismic unit := Fpunit'` 2 Mot wind unit H = 830.24lbft Mot seismic unit = 191.25 lb ft (wm�Mot wind_unit_.V = Pwind_utnt vert' 2 Mot wind unit V =473.56 lb ft Mot wind unit = Mot wind unit H + Mot wind unit V Mot wind unit '= 1303-8 lb ft w Mres Wp' m Mres=382.51b ft 2�0.6Mot wind unit fl 6'Mres� F _ (0.7•Mot_seismic_unit 0.6•Mres) Fup_wind_unit — up_setsmic._unit •— We wc Fup wind unit = 157.94 lb Fup eismic unit =—27.32lb WIND GOVERNS UNIT TO CURB E:\adcadd\19\00000-2019 Mechanical Units10237.01 American Heating Standards 20191Structural\Heat Pump at Wood Box\METAL DECK\IateraIMECH CIDA AMERICAN HEATING STANDARDS RNH TEL: (503)226-1285 CONDENSER UNIT 7/24/2019 FAX: (503)226 1670 ATTACHMENT Design attachment for 2991b sliding and 1581b tension at unit to curb connection—18GAcurb 0.6•Pwind_unit = 298.89 lb Fup w nd unit = 157.94lb Try#12x1 1/2"screws each end ofUrwstrut.(2)brackets to resist up ft,(4)trial nscrews_per_bracket I 0.6Pwind unit Fup_wind_unit Vx:= Vx= 74.72 lb Vy:- V = 78.9716 4.nscrewsj,er_bracket 2'nscrewsyer bracket Vscrew Y Vx2 + Vy2 Vscrew = 108.72 lb V a := atan( r a =46.58 deg Angle between grab and direction of loading l Vx Screw Dimensions and Capacities: dscrew 0.216in Screw Diameter Lscrew 1.5in Screw Length Lscrew Ltbread 3 Thread Length Lp Lscrew —0.25in Lp = 1.25 in Screw length-Angle Thickness Lp CD p:= Cp =0.58 10•dscrew V'II:= 1.6.250Ib•Cp V'n=231.48 lb V'T:= 1.6.2501b•Cp V'T=231.48 lb V11'VT V'a :_ / // 1 V', = 231.48 lb > Vs„,„ = 108.72 lb V'Iisin(a)2 + V'T•coS\a)2 Use(2)#12x1 1/2"wood screws at each bracket—(4)Brackets Minimum E:\adcadd\19100000-2019 Mechanical Units\0237.01 American Heating Standards 20191StructurahHeat Pump at Wood Box\METAL DECKtlateralMECH Alt CIDA AMERICAN HEATING STANDARDS RNH TEL: (503)226-1285 CONDENSER UNIT 7/24/2019 FAX:(503)226 1670 OVERTURNING-CURB TO ROOF LC#7 0.6D+0.6W LC#8 0.6D+0.7E WIND-Overturning at unit to curb SEISMIC-Overturning at unit to curb M (ot_wind_total_HP hmcElm,•_ wind' 2 •Jf Mot seismic total FP'2 Mot_wind_total_H = 1403.1 Ib ft Mot seismic total =340,71 lb ft wm Mot_wind_total_V Pwind total_vert' Mot wind total v = 757.05 lb ft Mot wind total Mot wind total H + Mot wind total V Mat wind total =2160.15 lb ft we Mres = 382.5lbft Mres:= Wt.2 (0.6Mot_wind_total —(16'Mres) (0•7'Mot_seismic total — 0.6•Mres) Fup wind total Fup seismic_total we We Fup_wind_total = 259.31 lb Fup_seismic_total =—42.86 lb WIND GOVERNS CURB TO ROOF ATTACHMENT Design attachment for 3891b sliding and 26016 uplift at curb to roof connection 0.6•Pw.ind= 388.55 lb Fup wind total = 259.31 lb A34 Clip with #9x1 1/2"SDS screws to wood and#8 SMS to steel roof Vallow_clip 455 lb nper_face_bracket 4 Fasteners per face of clip nclip_per_side := 1 Per Screw Vscrew I621b Tscrew 71 lb 0.6•Psind Fup wind total Uclip= Uclip =0.85 Uwithdrawat Uwithdrawal =0.91 Vallowcl ip 9 per_face_bracket'Tscrew 0.6•Pwind Uscrew_shear Uscrew_shear =0.3 2nclip_per_side'nper_face_bracket'Vscrew USE(1)A34 per side—(4)A34 total with(4)#9x1 12"SDS screws to wood,and(4)#8 SMS to steel roof E:\adcadd119100000-2019 Mechanical Units\0237.01 American Heating Standards 2019\Structural\Heat Pump at Wood Box\METAL DECK\IateralMECH ✓\ ' i )! / / 110Eakittp .1-1 1 " # . ;s'PROft i ry-„S GIIE / SECTION A—A i '"o1:0 • ,7 r ' f/ �_ ,7 - T OREGON '-- -' \ G , 13. 2� �� �T"S D. GPC'9 EXPIRES: 6/30/21 /270 LB HEAT PUMP 1 5/8" SUPERSTRUT EA. SIDE OF HEAT PUMP ATTACH TO UNIT W/ 3/8"0 BOLTS 6" 6" L3x3x1/4 x1 5/8" ATTACH W/ / MAX. , / MAX. / (1) 3/8"0 BOLT TO SUPERSTRUT AND A (1) #12x1 1/2" WOOD SCREW TO WOOD PLATFORM SIMPSON A34 EACH SIDE OF PLATFORM USE #9x1 1/2" SIMPSON SD SCREWS TO PLATFORM AND #8 SCREWS TO DECK iNAIL 2x12 EACH SIDE OF UNIT-- EXISTING 1 1/2" B DECK A CORNERS W/ (3) 16d MIN. N MAX SPAN = 7'—O" FOR 20GA DECK MAX SPAN = 9'—O" FOR 18GA DECK 2—SPAN MIN LAYUP REQUIRED NOTE: • LOCATE ONE EDGE OF PLATFORM OVER DECK SUPPORT BEAM/JOIST • IT IS ACCEPTABLE TO INSTALL CLIPS ON THE INTERIOR OR EXTERIOR OF 2x12 19/32" PLYWOOD PLATFORM-- PROVIDED CLIPS LAND ON A HIGH FLUTE NAIL TO 2x W/ 10d AT 6" O.C. ALL EDGES NOTE: VERIFICATION OF ROOF FRAMING BY OTHERS fillHEAT PUMP ATTACHMENT AT METAL DECK 1.. = ,._0„ Q DRAWING TL.E:HEAT PUMP ATTACHMENT DRAWING: Q TT PROJECT: I� APCNftECNAE 15895 SW 72ND Ave SUITE 200 AMERI�'AN HEATING STANDARD DETAIL L U ENGINEERING PORTLAND, OREGON 97224 C U U PLANNING ,„„,„s TEL : 503 . 226 . 1 285 LANDSCAPE FAX : 5 0 3 . 2 2 6 . 1 6 7 0 JOB: 190237.01 DATE:7.24.19 © EMI ca.hhc.ui amns RESERVED