Report New Unit /J,8C202c�-od3l/
/60 a7 clPPM_ 2 F
Job Name: „, .
Tag# � `
i Submittal Data Sheet FTK24NMVJU / RK24NMVJU
1
•1 2-Ton Wall Mounted Cooling Only System
Efficiency
Cooling
SEER 18
EER 12.5
* —'
r ,. _
J J '..1,...)
Performance
r , rj r� = .E_
JJr.l�. 1 '-I m wm- Cooling(Btu/hr)
i l J„ r r J, _ Rated(Min/Max) 21,200(5,500/24,000)
//r.ry gym : Sensible @ AHRI 15,760
r.nryr.NJr - �y
Moisture Removal gal/h 1.2
'* Standard Operating Range 50°F—115°F
Complete warranty details available from your local dealer or at Extended Operating Range* -4°F-115°F
www.daikincomfort.com.To receive the 12-Year Parts Limited Rated Cooling Conditions: Indoor:80°F DB/67°F WB
Warranty,online registration must be completed within 60 days of Outdoor:95'F DB/75'F WB
installation.Online registration is not required in California or Quebec. *With field settings and wind baffle
If product is installed in a commercial application,limited warranty
period is 5 years.
Electrical
Indoor Specifications 208/60/1 230/60/1
Cooling System MCA 18.3 18.3
H M System MFA 20 20
Airflow Rate(cfm) 713 579 Compressor RLA 12.0 12.0
L SL Outdoor fan motor FLA .38 .38
512 403
Sound(dBA) Outdoor fan motor W 58 58
H/M/L/SL 53/45/39/34 Indoor fan motor FLA .30 .30
Dimensions(H x W x D)(in) 11-5/8 x 39 x 10-3/8 Indoor fan motor W 46 46
Weight(Lbs) 27 MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A)
RLA:Rated load amps(A) W:Fan motor rated output(W)
Outdoor Specifications
Compressor Hermetically Sealed Swing Type
Refrigerant R-410A Piping
Factory Charge(Lbs) 3.20 Liquid (in) 1/4
Refrigerant Oil PVE(FVCSOK) Gas(in) 5/8
Cooling Drain (in) 5/8
Airflow Rate(cfm) H 2,101 Max. Interunit Piping Length (ft) 98.4
Max. Interunit Height Difference(ft) 65.625
SL 1,762 Chargeless(ft) 32.8
Sound Pressure Level(dBA) 55 Additional Charge of Refrigerant(oz/ft) .21
Dimensions(H x W x D)(in) 28-15/16 x 34-1/4 x 12-5/8
Weight(Lbs) 108
Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056
(Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date:December 2019 Page 1 of 4
z
O 5
i N
m
♦+ m
m m
m a
L
N
N
IMO m
Y
THE MARK(-,)SHOWS PIPING DIRECTION L1 AIR FLOW(INDOOR) c
O
REAR 39(99Dmm) - o
� ' I 1 �iIooiiJJliaiiiaiaoaiiaiiiai/i
LEFT I I I - RIGHT g ¢a o
I EO c
INCLUDING 4E w¢ o a
0 - MOUNTING PLATE b Q¢ tr.
c
10-rt6(265mm ; , Cl 1 _ m a t m
1038(263=0 1-15/16(50mm)MIN g m
- ._,,,! Enini (SPACE FOR 1-15/16(50mm)MIN
GENERAL RATING REQUIRED SPACE o d
MAINTENANCE) (SPACE FOR • N
NAMEPLATE MAINTENANCE) • c
cu TERMINAL BLOCK = m
`, •. _�) WITH EARTH II o y go� ■ - _ TERMINAL m D o
_ / (INSIDE) 5 o >-
' BOTTOM'
FRONT GRILLE FIXING SCREWS UP AND DOWN WIND DIRECTION - --"'
(INSIDE) N CONTROL BLADE MOVABLE RANGE n rz-
FLAPS `� GAS PIPE ABOUT 15-34(400mmi I DRAIN HOSE LL .-
GAS PIPE o5/8(o15-9rtm)CUT o
ABOUT 17-5'16(440mm) E
LIOUID PIPE �n
_" SIGNAL RECEIVER 1,7* 18-1/6(460mm) m " 'o
CO I''_ -OPERATION LAMP gmL`'
' �_ TIMERLAMP — -v 3
INDOOR UNIT ON/OFF SWITCHDRAIN HOSE - c
(� (CONNECTING PART LIQUID PIPE 01l4(06.4mm)CuT u N▪ m
ROOM TEMP.THERMISTOR I D 49116(o14mm) ABOUT 14-396(360mm)1 a, m
0 (INSIDE) 15
.11
MODEL NAME PLATE O.D.Qs/8(o16mm) ABOUT 14 3'6(365mm) E m a V. 0
ABOUT 17-3/4(450mm) r c
CU SIGNAL TRANSMITTER /BLADE ANGLES \ m 39(990mm) Z '-`
1-7/8(48mm) 13/16(20mm) r= c o
1 ., ..... ---- UP/DOWN(AUTOMATIC) m 29-3/81746mm $(126.5mm) Y
COOLING,DRY FAN ) T. N
C _� /J9 E E
W " E 15" ��//0. 10°c 1�� $ 4 a
�8 .0 55' 70' 80" '�, g
ooa RIGHT/LEFT(MANUAL) 1-7/8(48mml, • W0.ALL
I IOR EI EDDED PIPING 2-3/8(60mm ° N
�� 'N STANDARD LOCATIONS OF WALL HOLES 0-1/8(0BOmm)HOLE o E
> WIRELESS REMOTE CONTROLLER \ '-- A`.i9. / 3D091782 y 6
C (ARC4HOA9) +
C aN
�
Z m
m p
N C
u
N
Y
o >
aaz
N m
C -•
LL s E
m
g m
o 46
o o
3 m
W N
d d
N
MIMI
eo
co
HANDLE 9/16(14) 34-1/4(870) 2-3/4(70) OUTDOOR AIR THERMISTOR a
111
1/4(7) 12-518(320) 1-3/16(30) BRAND NAME PLATE ELECTRIC WIRE INTAKEc
LIIIIIII lir
7 • °
> `. 11 m
' y, ` ' , ',.l�,'!I MANUFACTURERS LABEL'
el
a ;177 ]:
)\‘iLr/�t�� l � 1 IM11111111i
3/4(19)
an
:41
1
a Yi _ liz l g on v m
0
4-HOLES FOR FOUNDATION BOLTS 9/16(14.5) 7!B(�) v c
MB OR M70 23-518(600) _I 4-15/16(125) 13-5J8(346) 7/16(11) n D.
(INSTALLATION LEG Ti tom
_'
PITCH) '.. c o u
_ E ._
coZS I - O R 14-1/2(368)
r..-- a p N
O N L
CO GROUND TERMINAL C I
O c 0 I1011 MINIMUM SPACE FOR AIR PASSAGE WALL HEIGHT ON AIR OUTLET SIDE co '� v( =LESS THAN 47-1/4(1200) 5 m Y
/fit -�. - GOOD O ^ U A
•V❑ --. LIQUID _ •w pi m °;
'[i-laiii-';; STOP VALVE 20-11/16(525) wiiiiviiiiivvuiiiiiry / 7 L y c
(®1/4(06.4)CUT) i -O -C c
GAS DRAIN o5 OUTLET)HOSE FOR 4 :2
C STOP VALVE (I.DCONNECTION WITH DRAIN JOINT) ; $ Clo - a
O (65/8(015.91CuT) i $ gl a 4 'L1 m a PyC SERVICE CO o I 1-15/16(50) 1-15/16(50) I 1-15/16(50)CD �� �' mv � �Svavu 'VE Fiiiiiiiiiruiiiiiriiiiiii firivvvrivriiiiiiviii/ mQ IIY (, ■I�1 Q
IL - !IIc co
0.,
Il unit inch(mm) u °
6-13/16(173) IN CASE OF REMOVING E
STOP VALVE COVER AND C:3D09223D °1 a,
__ TERMINAL STRIP COVER c i
m °1
Z m o
N
N e
n To
�/ To
..v •E
1a
O 1
V
Optional Accessories DAIKIN
Indoor Unit
Included Part Number Description _
BRP072A43 Wireless Interface Adapter(S21 Adapter Included)
BRC944B2-A08 Wired Remote Controller kit(Adaptor Required)
BRCW901A08 Wired Remote Controller Cable—25ft(Included in above kit)
BRCW901A03 Wired Remote Controller Cable—10ft
KRP980B2 Adaptor for wired remote controller(18&24)
KAF970A45 Titanium apatite photocatalytic au-purifying filter WITH frame
KAF970A46 Titanium apatite photocatalytic air-purifying filter WITHOUT frame
DACA-CP1-1 Inline Condensate Pump(Fits inside all Daikin wall&floor mount units)
DACA-CP4-1 External Condensate Pump
KRP928BB2S+KRP980B2 Interface Adaptor for DIII-NET
Outdoor Unit
Included Part Number Description
DACA-WB-1 Powder-Coated Wall-Mounted Bracket
KPW063B4 Air direction adjustment grille(18&24)
KEH063A4E Daikin BML Drain Pan Heater Large RX18,24&RXN18,24
KKG063A42 Back protection wire net(I8&24)
KKP937A4 Drain Plug for OD Unit
Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056
(Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without
notice and without incurring any obligations)
Submittal Revision Date:December 2019 Page 4 of 4
_ .
Existing Unit ��/ur(n. f.'.v1) ' p
MITSUBISHI MAY 2 0 2020 Art ELECTRIC C;i 'OFDGA S�II�If. ®
HVAC Advanced Products Division ` f • i.' • - `('r?,''' Split Zoning A/C and Heat Pumps
SUBMITTAL DATA: MSY A24NA & MUY A24NA 24,000 BTU/H WALL-MOUNTED AIR-CONDITIONING SYSTEMS
- Job Name: Location: Date:
' Purchaser: Engineer:
Submitted to: For ❑Reference ❑Approval Construction
Unit Designation: Schedule No.:
GENERAL FEATURES
•Wall-mounted indoor unit for residential applications
•Compact side discharge outdoor unit
•Zone control
•Quiet operation for both indoor and outdoor units
•"Powerful Mode"function permits system to temporarily run at a Indoor Unit:MSY-A24NA w 1
lower/higher temperature with an increased fan speed,which
quickly brings the room to the optimum comfort level —
•Wireless remote controller is included
•Indoor unit powered from outdoor unit using A-Control i Div
•Automatic restart following a power outage
•Self-check functon—onboard diagnostics
•Dry Mode function is standard Outdoor unit:MUKA24NA
•Limited warranty:five years on parts and defects and seven years
on compressors _
Wireless Remote Controller
Indoor Unit
MCA 1 0 A
OPTIONAL ACCESSORIES Fan Motor 076 F.L.A.
Indoor Unit Airflow(Lo-Med-Hi-Powerful)
Adapter MAC-3991F Cooling 296-431 -568-624 Dry CFM
• M-NET Control Ada
P ( ) 265-385-508-558 Wet CFM
• MA Contact Terminal Interface(MAC-3971F)
•Wired Remote Controller(PAR-21MAA; requires MAC-3971F) Sound Pressure Level(Lo-Med-Hi-Powerful)
• Condensate Pump(230V; S13100-230) Cooling 34-40-49-51 dB(A)
•Anti-allergy Enzyme Filter(MAC-2300FT)
•Three-pole Disconnect Switch(TAZ-MS303) DIMENSIONS UNIT INCHES/MM
W 43-5/16/1,100
D 10-1/4/260
H 12-13/16/325
Weight 37 lbs./17 kg
External Finish Munsell No.3Y 7.8/1.1
Field Drainpipe Size O.D. 5/8"/15.88 mm
Remote Controller Wireless
Outdoor Unit
Cooling` Compressor DC-driven Inverter Twin Rotary
Rated Capacity 22,000 Btu/h MCA 17 A
Minimum Capacity 4,400 Btu/h S 0.93 F.L.A.
SEER 16.0 u Sound Pressure Level
Total Input 2,880 W Cooling 55 dB(A)
*Rating Conditions(Cooling)-Indoor:80°F(27°C)DB,67°F(19°C)WB;
Outdoor:95°F(35°C)DB,75°F(24°C)WB. DIMENSIONS INCHES/MM
Power Supply 208/230V, 1-Phase,60 Hz W 33-1/16/840
Breaker Size 20 A D 13/330
Voltage H 33-7/16/849
InSoor-Outdoor S1-S2 AC 208/230V
Inc:oor-Outdoor S2-S3 DC 12-24V Weight 128 lbs./58 kg
Indoor-Remote Controller Wireless External Finish Munsell 3Y 7.8/1.1
OPERATING RANGE Refrigerant Type R410A
Indoor Intake Air Temp. Outdoor Intake Air Temp. Refrigerant Pipe Size O.D.
Gas Side 5/8"/15.88 mm
90°F(32°C)DB Liquid Side 1/4"/6.35 mm
Maximum 115°F(46°C)DB q
Coolin 73°F(23°C)We Max. Refrigerant Pipe Length 100 ft./30 m
9 67°F(19°C)DB, Pipe 9 Max. Refrigerant Height Difference 50 ft./15 m
minim„,.,, 57°F(14°C)WB 14°F(-10°C)DB Connection Method Flared
MI6 I E R
r • DIMENSIONS: MSY-A24NA & MUY A24NA
MSY-A24NA Unit: inch
42-1/16 Installation plate Indoor unit
3-7/8 / 6-13/16 m
ui
1 ===___ _� - -- - - - -i- - --
_ 1 I
L_ _+Z_ -------- �7•
CO CO
43-5/16 lc 7/8 16-5/16 16-5/16 6-13/16
a
1.
I I Wall hole 03
CD }
10-1/4 3/16
Air incti Installation plate
Liquid line 01/4 19-11/16
2-3/16 31-1/8 9-15/16 1 Gas line 05/8 16-15/16
Insulation 01-15/16 O.D
01-1/4 I.D
2-5/16 13/4
. - Drain hose 05/8
rb�1 -
Air out (Connected part O.D)
Insulation 01-1/8
Wireless remote controller
MUY-A24NA REQUIRED SPACE open as a rule Unit:Inch
20 inch or more If
20.e12 . the front and both
� sides are open
1-BHB
AI .. 4 Inds or more/
8 inch or more if
- ` iiiii`� there are a obstacles
to both sides
Air In 4, -- I' ft 0
di,�, I 1 //r rQi �t�,,�
Air out
t&11I16 .I d-3/8x13/18 Oval hde �� y' '•o,. ""r8
33-1116 3-3/16 Open as a rule
- 4-25/32 -' - 20 inch or more If the back,
both sides and top are open
.
-1
- Service panel
I j4, �\\ = Liquid refrigerant
�����//%f\� �` po pipe joint
Illu��/011llrr ,t61101�% Refrigerant pipe
I111 `
n \,so�11«\ji V: (flared)e1/4
dditt
- �--- 11 _ia
,y 1� j•
Gas refrigerant
— -— t --} pipe joint gm Refrigerant pipe
(flared)05/8
MITSUBISHI
m ENERGYJTAR ELECTRIC
wwwLuu�a-' CERTIFIED PARTNER HVAC Advanced Products Division
34387501 0AG 3400 Lawrenceville Suwanee Rd
AH1 5 Standard210/240 Suwanee,GA 30024
aaaai,.„r�•,.»�,.��•.,m•.x.n�.�,...»�.•n O/STO ® Tele:678-376.2900•Fax:800-889-9904
Toll Free:800-433-4822(p3)
www.mehvac.com
C SD-MSY-A24NA&MUY-A24NA-200905 0 MITSUBISHI ELECTRIC/HVAC 2009 Specifications are subject to change without notice.