Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
OFFICE COPY PRIME ELECTRICAL SERVICES, LLC. RECEIVED Electrical ♦ Communications♦ Life Safety • Security• CCTV PO Box 872395 Vancouver,WA 98687♦Phone(360)335-3565 MAY 6 2020 OR CCB#217825♦ WA#PRIMEES822BE CITY OF TIGARD BUILDING DIVISION FIRE ALARM SYSTEM SUBMITTAL Durham Creekside Building SW Durham Rd. Tigard, OR 97224 March 30, 2020 OFFICE COPY Proposed by Prime Electrical Services PO 20-167 Project Manager: Oleg Primachenko Honeywell ri SILENT' KNIGHT EVS-50W Intelligent 50 Watt Amplifier The EVS-50W is an intelligent 50 watt amplifier for use with the 5820XL- EVS or 6820EVS.The EVS-50W is used to amplify the audio message for distribution throughout the facility.Since it is designed as a self-contained distributed amplifier it can be conveniently located near the area of I protection to reduce wiring demands. Each EVS-50W is capable of producing 50-watts of audio power.Up to four EVS-50W's can be used on the voice evacuation system. The EVS-50W has its own power supply with battery backup and four speaker circuits which can be expanded to eight speaker circuits with the optional EVS-CE4.The EVS-50W is fully supervised by the main panel for trouble conditions. INSTALLATION The EVS-50W can be surface or flush mounted. COMPATIBILITY EVS-50W The EVS-50W is compatible with the following Honeywell Silent Knight Series FACPs: • 6820EVS:Addressable fire alarm control panel with an emergency voice system,up to 1,110 addressable points,and four programmable buttons that can be programmed for routine or complex tasks • 5820XL-EVS:Addressable fire alarm control panel with an emergency voice systems and up to 792 addressable points FEATURES & BENEFITS • Integrates directly • Communicators • Accounts can be easily • Includes Quality of • Programmable with Silent Knight provide dual path managed through Service(QOS) supervision time from Series 6000 panels. cellular and IP on-line management diagnostics via 1 to 60 minutes Installation is easy as reporting capability tools AlarmNet which • Provides full data there is no need for when combined with conveys vital • Remote mount up to reporting using special programming 6000 series panels 6000 feet to ensure communicator Contact ID format or a separate dialer • UL 864 and NFPA 72 best reception information,including capture module code compliant for when messages are • Battery backup sole,primary,or received,signal provided by the fire backup strength,and message alarm control panel for communications path used enhance efficiencies and cost savings it EVS-50W Technical Specifications Fora complete listing of all compliance approvals and PHYSICAL ORDERING INFORMATION certifications,please visit www.silentknight.com. Flush Mount Dimensions:14.5"W x 24.75"H x EVS-50W: Intelligent SO Watt Amplifier 3.4"D(36.8 W x 62.9 H x 8.7 D cm) Microsoft,Windows,and Overall Dimensions:16.1"W x 26.5"H x 4.1"D(40.6 ACCESSORIES the Windows Logo are W x 66.7 H x 10.5 D cm) EVS-CE4: Adds four additional audio circuits to the registered trademarks Color:Red EVS-50W. or trademarks of Microsoft Corporation. RBB: Remote Battery Box Accessory Cabinet.Use ENVIRONMENTAL for backup batteries up to 35 AH. Silent Knight'and • Operating Temperature:32°F to 120°F (0°C to AB55: Remote Battery Box Accessory Cabinet Use Honeywellmareregistered tra49°C) for back batteries upto 55AH and too large to fit International, anonmarks 1, Honeywell g International,Inc Humidity:10 to 93%relative humidity(non- into EVS-50W Cabinet. condensing) This document is not AGENCY LISTINGS AND APPROVALS intended to be used for ELECTRICAL UL 864 and UL 2572 installation purposes.We try to keep our product Primary AC:120 VAC @ 60Hz Meets the requirements for NFPA 72 Local information up-to Standby Current:85mA @ 25 Vrms;100mA® Protective Signaling Systems&Emergency date and accurate.We 70.7Vrms Communication Systems. cannot cover all specific Alarm Current:525mA @ 25 rms;580mA® CSFM 7165-559:0172 applications or anticipate 70.7Vrm all requirements.All specifications are subject Total Power:50W @ 25 Vrms or 70.7Vrms to change without notice. •Circuit 1-4:Rated at 50W each For Technical •EVS-CE4 Circuits 5-8:Rated at 50W Support.Please call Main ECS Panel SBUS Standby&Alarm:10mA 800-446-6444. Battery Charging Capacity:7—35AH Battery Size:18AH max allowed in cabinet.Use RBB accessory cabinet for larger batteries up to 35AH per system. Voice Integration Wiring: Six conductor Two voice bus Four SBUS T For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 SILENT' Doc 3506051 Rev D 105/18 ®I ILEN1' 800-328-0103 ©2018 Honeywell International Inc. Honeywell 0 SILENT' KNIGHT 5496 Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today.It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor,Gentex•', AMSECO,and Wheelock.The 5496's advanced microprocessor design is years ahead of the competition.Its switch mode power supply design is up to 50%more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection,battery charging circuit,and backup battery for use with the Honeywell Silent Knight series fire alarm control panels(FACPs).The 5496 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act """ci (ADA).The 5496 has built-in ANSI cadence pattern.The output circuits can be programmed as notification appliance circuits,or as auxiliary power(configurable for constant,resettable,or door holder power). Compatibility 5496 The 5496 is compatible with the following Honeywell Silent Knight FACPs: • 6820/6820EVS • 5820XL/5820XL-EVS • 6808 • 6700 • 5808 • 5700 FEATURES & BENEFITS • UL Listed for 6 amps • Built-in • NACs are • Communicates to the • Lightweight design of notification power synchronization for programmable as FACP via 4-wire SBUS adds to ease of • Powersupply's appliances from notification appliance (wire runs up to 6000 installation and advanced switch mode Gentex,AMSECO, circuits,or as auxiliary ft) reduces shipping design reduces System Sensor,and power to be used as • AC loss delay option costs dama in heat and Wheelock constant,resettable, shuts off power to • g g or door holder power ANSI Cadence pattern manages power up to • Four power-limited non-essential high output capability 50%more efficiently notification outputs;2 • 3 amps per output current accessories built-in than other systems Class A or 4 Class B,or circuit like magnetic door • UL 864,1481&1971 1 Class A and 2 Class holders • 24 VDC filtered output • Ground fault detector Listed voltage B •• CSFM approved MEA approved • OSHPD(CA) OSP-0065-10(see accessories) C 5496 Technical Specifications For a complete listing of all compliance approvals and 4 Outputs Programmable certifications,please visit p 9 www.silentknight.com. as Notification Appliance Circuits, or as Auxiliary Power teWindows Microsoft,Windows,are and the Windows Logo are registered trademarks opSBUS Communication Microsofttorpof Output 1 �, Mcosoft Corporation. To a Compatible . Silent Knight FACP System Sensor'and Output 2 Honeywell®are registered 1100. trademarks of Honeywell International,Inc Output 3 . This document is not intended to be used for Output 4 Il installation purposes.We try to keep our product information up-to Auxiliary Power Can Be date and accurate.We cannot cover spec Programmed To Be Constant, applications orr anticipate Resettable, or Door Holder Power all requirements.All specifications are subject to change without notice. For Technical Support, PHYSICAL required on each Class B circuit ca11800-446-6444 Overall Dimensions:16"H x 12.25"W x 3"D(40.6 x Battery Charging Capacity:7.0-35.0AH 30.9 x 7.6 cm) Shipping Weight:8.71bs ORDERING INFORMATION ENVIRONMENTAL 5496:Intelligent Power Module Operating Temperature:32°F to 120°F (0°C to ACCESSORIES 49°C) RBB: Remote Battery Box Accessory Cabinet.16" Humidity:10to93%relative humidity(non- Wx 10"H x 6"D(406 mm Wx 254 mm H x 152 mm condensing) D) ELECTRICAL: SK-SCK: Seismic Compliance Kit AC Input:120VAC at 2.7A AGENCY LISTINGS AND APPROVALS Output:24VDC at 6A • CSFM approved Standby&Alarm Current:10mA Notification/Aux.Power Circuits:4 • NFPA 72 Output Configuration: • UL listed 2 Class A(Style Z) 4 Class B(Style Y) • FM approved 1 Class A&2 Class B Amps Per Output Circuit:3.0(6.0 amps total) • City of NY:429 90 E Vot XIV Notification Circuit Output:20.4-27.3VDC C� 3.0A each End-of-Line Resistance:4.7k W EOL resistor For more information Learn more about Silent Knight's Product and other products available by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 800 328 0103 Doc 3503871 Rev FI 11/17 D SILENT www.silentknight.com 02017 Honeywell International Inc. IChIIGI ---411.11111 Honeywell SILEGHTNT' KNI SK-ISO Intelligent Fault Isolator Module The SK-ISO is an addressable line isolator module for use with the Honeywell Silent Knight Series fire alarm control panels(FACPs). The SK-ISO acts as an automatic switch that opens when the line voltage on the signaling line circuit(SLC)loop drops below four volts.Isolator modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop.If a short occurs between any two isolators, then both isolators immediately switch to an open circuit state and isolate the devices between them.The remaining units on the SLC loop continue to fully operate.No more than 25 devices are recommended for each group. SK-ISO INSTALLATION The SK-ISO mounts directly into a 4"square electrical box.The box must have a minimum depth of 2-1/8".A surface mount electrical box(System Sensor°PN SMB500)is available from Silent Knight. FEATURES & BENEFITS • Panel controlled • Protects the modules • SEMS screws for easy status LED that on the SLC loop so wiringUL Listed flashes green in other devices continue • CSFM Listed normal state and is to operate solid red in alarm • FM Approved • Standard 4 inch • Isolates short circuits electrical box on an SLC loop mounting SK-ISO Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions:4.5"H x 4"W x 0.25"D(11.4x 10.2 x SK-ISO:Line isolation module 6cm) Microsoft.Windows,and the indos Logo Shipping Weight:6.3 oz(196 g) ACCESSORIES registered trademarks SMB500:4"Square Surface Mount Electrical Box or trademarks of ELECTRICAL Microsoft Corporation. Operating Voltage:15-32 VDC COMPATIBILITY tem Standby Current:450 µA max(not isolating:relay The SK-ISO is compatible with the following Silentn rKnight*,adoneywe p 9 Sensor°'andHoneywell' closed) Honeywell Silent Knight fire alarm control panels: are registered Isolation Current:5mA max 6820:Addressable fire alarm control panel trademarks of Honeywell Fault Detection Delay:250ms min. 6820EVS:Addressable fire alarm control panel International.Inc. Fault Detection Threshold:4V with an emergency system. This document is not Line Restoration Threshold:7V 6808:Addressable fire alarm control panel intended to be used for 6700:Addressable fire alarm control panel installation purposes.We try to ENVIRONMENTAL 5700:Addressable fire alarm control panelinformation up-to Operating Temperature:32°F-120°F(0°C- 5808:Addressable fire alarm control panel date and accurate.We 49°C) 5820XL:Addressable fire alarm control panel cannot coverallspecific Humidity:l0%-93%non-condensing 5820XL EVS:Addressablefirealarmcontrolpanel all applications or anticipate requirements.All with an emergency voice system specifications are subject to change without notice. For Technical Support, call 800-446-64L4. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 3501341 Rev F 111/17 SILENT' 800-328-0103 e 2017 Honeywell International Inc. KNIGHT Honeywell DSILENT' KNIGHT SK-MONITOR Intelligent Monitor Module The SK-MONITOR is an addressable monitor module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-MONITOR is intended for use in intelligent,two-wire systems,where individual address of each module is selected using the built-in rotary switches. The SK-MONITOR supports Class A supervised or Class B supervised wiring to the load device.Conventional4-wire smoke detectors can be monitored for alarm and trouble conditions. INSTALLATION The SK-MONITOR mounts directly into a 4"square electrical box.The box must have a minimum depth of 2-1/8".A surface mount electrical box (System Sensor®PN SMB500)is available from Silent Knight. SK-MONITOR FEATURES & BENEFITS • Single contact monitor • Panel controlled • UL Listed • Support for Class A status LED that • Rotary address and Class B wiring flashes green in switches for fast normal state and is installation • Fully supervised solid red in alarm • SEMS screws for easy wiring C SK-MONITOR Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Height:4.5"H x4"W x 1.25"D(11.4X 10.2 X 3cm) SK-MONITOR:Monitor Module MShipping Weight:6.3 oz(196 g) thecrosoft.Windows Logo a,eand ACCESSORIES. Logo are registered trademarks ELECTRICAL SMB500:4"Square surface mount electrical box or trademarks of Operating Voltage:15-32VDC Microsoft Corporation. Current Draw(LED on):5.0mA max COMPATIBILITY Silent Knight,System Operating Current(LED flashing):375µA The SK-MONITOR is compatible with the Sensor'and Honeywell' Standby Current:400 µA max®24 VDC(one following Honeywell Silent Knight fire alarm are registered communication every 5 sec with 47K EOL);550 µA control panels: trademarks of Honeywell max®24 VDC(one communication every 5 sec 6820:Addressable fire alarm control panel International,Inc. with EOL<1K) 6820EVS:Addressable fire alarm control panel This document is not 5.5 mA(with LED latched on) with an emergency mass notification system. intended to be used for LED Current:5.5 mA(with LED latched on) 6808:Addressable fire alarm control panel installation purposes.We End-of-Line Resistance:47K S2 6700:Addressable fire alarm control panel try to keep our product information up-to Initiating Device Circuit Wiring Resistance:1,500 5700:Addressable fire alarm control panel date and accurate.We S2max 5808:Addressable fire alarm control panel cannot cover all specific SLC Loop Resistance:40S2max. 5820XL:Addressable fire alarm control panel applications or anticipate all requirements.All ENVIRONMENTAL 5820XL-EVS:Addressable fire alarm control panel specifications are subject with an emergency mass notification system to change without notice. Operating Temperature:32°F-120°F(0°C- 49°C) For Technical Support, Humidity:10%-93/a non-condensing gal 800 4a6 6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com HoneywellSil ClintonClintonville tadight Honeywell 12 Clintonville Road Northford,CT 06472 Doc 3501311 Rev GI 11/17 SILENT' 800-328-0103 r°2017 Honeywell International Inc. ®KNIGHT Honeywell SILEN KNIGHTT SK-MINIMON Intelligent Mini Monitor Module The SK-MINIMON is an addressable monitor modules for use with the Honeywell Silent Knight fire alarm control panels(FACPs).The SK- MINIMON `� acts as an interface to contact devices,such as waterflow �49 t switches and pull stations.The SK-MINIMON supports Class B supervised " . wiring to the load device.Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device.Its small size and lightweight allow it to be installed without rigid mounting requirements. SK-MINIMON INSTALLATION The SK-MINIMON can be mounted in a single gang junction box directly behind the monitored device.Its small size and light weight allow it to be installed without rigid mounting requirements. FEATURES & BENEFITS • Single contact monitor • Rotary address • SK-Minimon support switches for fast for Class B(Style B) installation contact monitor wiring • UL Listed • Small and lightweight • CSFM Listed size allows for flexible • FM Approved mounting options SK-MINIMON Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions:2.75"Wx 1.3"H x 0.5"D SK-MINIMON:Mini monitoring module Microsoft,Windows,and Weight:1.2 Oz(37 g) the Windows Logo are COMPATIBILITY registered trademarks ELECTRICAL The SK-MINIMON is compatible with the or trademarks of Operating Voltage:15-32VDC following Honeywell Silent Knight fire alarm Microsoft Corporation. SLC Standbyand Alarm Current:350 A control panels: R Silent Knight'',System End-of-Line Resistance:47K S2 6820:Addressable fire alarm control panel Sensors and Honeywell' Initiating device circuit wiring resistance:1,50052 6820EVS:Addressablefire alarm control panel are registered max with an emergencyvoice system. trademarks of Honeywell SLC loop resistance:400 max 6808:Addressable fire alarm control panel International,Inc. Wire Length:6"min. 6700:Addressable fire alarm control panel This document is not 5700:Addressable fire alarm control panel intended to be used for ENVIRONMENTAL 5808:Addressable fire alarm control panel nstauation purposes.We try to keep our product Operating Temperature:32°F-120°F(0°C- 5820XL:Addressable fire alarm control panel information up-to 49°C) 5820XL-EVS:Addressable fire alarm control panel date and accurate.We Humidity:10%-93%non-condensing with an emergencyvoice system cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For Technical Support. call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 3501331 Rev G 111/17 MI SILENT' 800-328-0103 ©2017 Honeywell International Inc. KNIGHT Honeywell SILENT' KNIGHT SK-RELAY Intelligent Relay Module The SK-RELAY is an addressable relay module for use with Honeywell Silent Knight Series fire alarm control panels(FACPs).The SK-RELAY allows a Silent Knight FACP to switch discrete contacts by code command.The relay contains two isolated sets of Form C contacts,which operate as a f, DPDT switch.No supervision is provided for the notification appliance circuit. Honeywell '; The SK-RELAY contacts can be used for virtually any normally open or 'ZT;rr normally closed application.Each SK-RELAY is programmed with a unique signaling line circuit(SLC)loop address.When an event occurs that controls the SK-RELAY,the relay is triggered by the FACP. INSTALLATION The SK-RELAY mounts directly into a 4"square electrical box.The box must SK RELAY have a minimum depth of 2-1/8".A surface mount electrical box(System Sensor*PN SMB500)is available from Silent Knight. FEATURES & BENEFITS • Two sets of Form C • Panel controlled • Polling LED visible contacts status LED that through the cover • Rotary address flashes green in plate switchesforfast normal state and is • SEMS screws for easy installation solid red in alarm wiring • Contacts are rated for • Relay programming is • UL Listed a variety of amps(see completely flexible- Specifications) can be mapped to zone conditions C SK-RELAY Technical Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. 4.675"H x 4.275"W x 1.4"D SK-REIAY:Relay Module Microsoft,Windows,and Shipping Weight:6.3 oz(196 g) the Windows Logo are ACCESSORIES. registered trademarks ELECTRICAL SMB500:4"Square Surface Mount Electrical Box or trademarks of Operating Voltage:15-32 VDC CB500:Module Barrier Microsoft Corporation. End-of-Line Resistance:Not used Silent Knight',System SLC Standby&Alarm Current:.255mA max @ COMPATIBILITY Sensor'and Honeywell' 24VDC(one communication every 5 sec with LED The SK-RELAY is compatible with the following are registered enabled) Honeywell Silent Knight fire alarm control panels: trademarks of Honeywell 6820:Addressable fire alarm control panel International,Inc. ENVIRONMENTAL 6820EVS:Addressable fire alarm control panel This document is not Operating Temperature:32°F-120°F(0°C- with an emergency mass notification system. intended to be used for 49°C) installation purposes.We 6808:Addressable fire alarm control panel Humidity:10%-93%non-condensing 6700:Addressable fire alarm controlpanel try to keep our product information up-to RELAY CONTACT RATINGS 5700:Addressable fire alarm control panel date and accurate.We 3.OA®30VDCresistive 5808:Addressable fire alarm control panel cannot cover alt specific 5820XL:Addressable fire alarm control panel appticairementsons or All anticipate 0.9A®110VDC resistive all requirements.All 0.9A 125VAC resistive 5820XL-EVS:Addressable fire alarm control panel specifications are subject 0.5A 125VAC inductive(PF=.35) with an emergency mass notification system. to change without notice. 0.7A®75VAC inductive(PF=.35) For Technical Support, call 800-446-6444. For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight Honeywell 12 Clintonville Road Northford,CT 06472 Doc 3501271 Rev GI 11/17 SILENT 800-328-0103 ©2017 Honeyweu International Inc. NW KNIGHT _ p T _W SK HO O SERIES Addressable Photoelectric Smoke Detectors The Silent Knight® SK-PHOTO-W Series feature a modern design and expanded color options support a variety of contemporary aesthetic demands. In addition, each detector is constructed for exceptional installation and maintenance efficiency. - The SK-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics,and are direct replacements for the SK-PHOTO Series detectors.A new modern,sleek,contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards.The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software.Sensitivity is continuously monitored and reported to the panel.Point ID capability allows each detector's address to be set with rotary,decimal address switches,providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level.Dual electronic thermistors add 135°F(57°C)fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. FEATURES AND BENEFITS • Designed to meet UL 1268 7th Edition steady red in Alarm • Sealed against back pressure • Sleek and stylish contemporary design • Integral communications and built-in • Plugs into separate base for ease of • Stable communication technique with device-type identification installation and maintenance noise immunity • Remote test feature from the panel • Expanded color options • Addressable by device • Built-in functional test switch activated by • SEMS screws for wiring of the separate base • Rotary,decimal addressing(Refer to the external magnet • Optional remote,single-gang LED Silent Knight panel manuals for device • Walk test with address display(an address accessory capacity) of 121 will blink the detector LED 12- • Optional sounder,relay,and isolator bases • Two-wire SLC connection (pause)-1) • LEDs blink every time the unit is polled • Low standby current • 360°-field viewing angle of the visual alarm • Built-in tamper-resistant feature indicators(two bi-color LEDs);LEDs blink • Designed for direct-surface or electrical- Honeywell green in Normal condition and turn on box mounting SILENT' lima KNIGHT ' INSTALLATION B200SR-LF-WH:White,Low Frequency Intelligent sounder base The SK-PHOTO-WSeries plug-in intelligent thermal detectors use a for retrofit applications separate base to simplify installation,service,and maintenance. B200SR-LF-IV:Ivory,Low Frequency Intelligent sounder base for Installation instructions are shipped with each detector. retrofit applications Mount base(all base types)on an electrical backbox which is at B224RB-WH:White,plug-in System Sensor°relay base least 1.5'(3.81 cm)deep.For a chart of compatible junction boxes, B224RB-IV:Ivory,plug-in System Sensor relay base see SK-61045. B224BI-WH:White,plug-in System Sensor isolator detector base Note:Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required.Wiring"T-taps"or branches B224BI-IV:Ivory,plug-in System Sensor isolator detector base are permitted for Style 4(Class"B")wiring. ACCESSORIES Note:When using relay or sounder bases,consult the SK-ISO TR300:White,replacement flange for B210LP or B300-6 bases installation sheet 156-3627 for device limitations between isolator TR300-IV:Ivory,replacement flange for B210LP or B300-6 bases modules and isolator bases. RA100Z(A):Remote 3-32 VDC LED annunciator,mounts to a U.S. OPERATION single-gang electrical box,for use with B501 and B300-6 bases Each SK-PHOTO-W Series detector uses one of the panel's addresses only (total limit is panel dependent)on the Signaling Line Circuit(SLC).It M02-04-00:Test magnet responds to regular polls from the control panel and reports its type and the status.If it receives a test command from the panel(or a local M02-09-00:Test magnet with telescoping handle magnettest),it stimulates its electronics and reports an alarm.It blinks CK300:White,detector color kit,pack of 10 its LEDs when polled and turns the LEDs on when commanded by the CK300-IV:Ivory,detector color kit,pack of 10 panel.The SK-PHOTO-W Series offers features and performance that CK300-BL Black,detector color kit,pack of 10 represent the latest in smoke detector technology. PRODUCT LINE INFORMATION Note:"-IV"suffix indicates ivory color. SK-PHOTO-W:White,low-profile photoelectric sensor SK-PHOTO-T-W:White,same as SK-PHOTO-W but includes a built-in 135°F(57°C)fixed-temperature thermal device SK-PHOTO-R-W:White,low-profile intelligent photoelectric sensor, remote test capable,for use with DN R/DN RW B300-6:White,standard flanged low-profile mounting base B300-6-BP:Bulk pack of B300-6,package contains 10 B300-6-IV:Ivory,standard flanged low-profile mounting base B501-WHITE:White,standard European flangeless mounting base B501-BL:Black,standard European flangeless mounting base B501-IV:Ivory,standard European flangeless mounting base B501-WHITE-BP:Bulk pack of B501-WHITE,contains 10 B200S-WH:White,Intelligent,programmable sounder base B200S-IV:Ivory,Intelligent,programmable sounder base B200SR-WH:White,Intelligent sounder base for retrofit applications B200SR-IV:Ivory,Intelligent sounder base for retrofit applications B200S-LF-WH:White,Low Frequency Intelligent,programmable sounder base B200S-LF-IV:Ivory,Low Frequency Intelligent,programmable sounder base Page 2 of 3—351634:B•7/1/2019 SK-PHOTO-W SERIES TECHNICAL SPECIFICATIONS PHYSICAL/ENVIRONMENTAL DETECTOR SPACING AND Sensitivity: APPLICATIONS Silent Knight'and System Sensor" 0 o Silent Knight recommends spacing are registered trademarks of - UL Applications:0.5/o to 4.0/o per foot Honeywell International,Inc. obscuration. detectors in compliance with NFPA 72.In - ULC Applications:0.5%to 3.5%per foot low airflow smooth ceiling, This document is not intended to be obscuration space detectors 30 feet(9.1m).For specific used for installation purposes.We information regarding detector spacing, try to keep our product information Size:2.0'(5.3 cm)high;base determines placement,and special applications refer to diameter up-to-date and accurate.We cannot NFPA 72.ASystem Smoke Detector cover all specific applications or - B300-6:6.1"(15.6 cm)diameter Application Guide,document A05-1003,is anticipate all requirements.All - B501:4'(10.2 cm)diameter available at www.systemsensoccom. specifications are subject to change For a complete list of detector bases,see AGENCY LISTINGS AND without notice. SK-61045. APPROVALS Country of origin:Mexico Shipping weight:3.4 oz.(95 g) These listings and approvals apply to the Operating temperature range: modules specified in this document.ln some • SK-PHOTO-W:32°F to 122°F(0°C to 50°C) cases,certain modules or applications may • SK-PHOTO-T-W:32°F to 100°F(0°C to not be listed by certain approvalagencies,or 38°C) listing may be in process.Consult factory for • SK-PHOTO-R-W installed in a DNR/DNRW: latest listing status. -4°F to 158°F(-20°C to 70°C) • UL Listed:S6173 UL/ULC Listed Velocity Range:0-4000 ft/ • FM Approved min.(1219.2 m/min.),suitable for • CSFM:7272-0559:0512 installation in ducts Relative humidity:10%-93%non- condensing Thermal ratings:fixed-temperature set point 135°F(57°C),rate-of-rise detection 15°F(8.3°C)per minute,high temperature heat 190°F(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(one communication every 5 seconds with LED enabled) Max current:4.5 mA c 24VDC CON") Honeywell Silent Knight 12 Clintonville Road Northford,CT06472-1610 Honeywell 203.484,7161 35163413I07/19 E71 SILENT' www.silentknight.com ©2019 Honeywell International KNIGHT SERIES Addressable Heat Detectors The Silent Knight® SK-HEAT-W Series heat detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the SK-HEAT-W Series Iideal for both system operation and building design. The series includes a 135°F/57°C fixed-temperature,rate-of-rise,and a 180°F/88°C fixed high-temperature detectors and are direct replacements for the SK-HEAT Series heat detectors.The point ID address,set using rotary decimal switches,provide specific detector locations.These thermal detectors provide effective,intelligent property protection in a variety of applications. • SK-HEAT-W offers 135°F fixed thermal detection. • SK-HEAT-ROR-W offers 135°F fixed and rate-of-rise thermal detection. • SK-HEAT-HT-W provides fixed high-temperature detection at 190°F. FEATURES AND BENEFITS • Designed to meet UL 268 7th Edition • 360°-field viewing angle of the visual alarm • Designed for direct-surface or electrical- • Sleek and stylish contemporary design indicators(two bi-color LEDs);LEDs blink box mounting • Advanced thermal technology for fast green in Normal condition and turn on • Sealed against back pressure response steady red in Alarm • Plugs into separate base for ease of • Fixed temperature model(SK-HEAT-W) • Integral communications and built-in installation and maintenance factory preset to 135°F(57°C) device-type identification • SEMS screws for wiring of the separate base • Rate-of-rise model(SK-HEAT-ROR-W), • Remote test feature from the panel • Optional remote,single-gang LED 15°F(8.3°C)per minute • Built-in functional test switch activated by accessory • High temperature model(SK-HEAT-HT-W) external magnet • Optional sounder,relay,and isolator bases factory preset to 190°F(88°C) • Walk test with address display(an address • Optional flanged surface mounting kit • Addressable by device of 121 will blink the detector LED 12- • Rotary,decimal addressing(Refer to the (pause)-1) Silent Knight panel manuals for device • Low standby current capacity) • Built-in tamper-resistant feature Honeywell • Two-wire SLC connection • LEDs blink every time the unit is polled SILENT' ®KNIGHT APPLICATIONS B200SR-LF-IV:Ivory,Low Frequency Intelligent sounder base for Use thermal detectors for protection of property.For further retrofit applications information,refer to manual 156-6529,Applications Manual for B224RB-WH:White,plug-in System Sensor®relay base System Smoke Detectors,which provides detailed information on B224RB-IV:Ivory,plug-in System Sensor relay base detector spacing,placement,zoning,wiring,and special B224BI-WH:White,plug-in System Sensor isolator detector base applications. B224BI-IV:Ivory,plug-in System Sensor isolator detector base INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a ACCESSORIES separate base to simplify installation,service,and maintenance. TR300:White,replacement flange for B210LP or B300-6 bases Installation instructions are shipped with each detector. TR300-IV:Ivory,replacement flange for B210LP or B300-6 bases Mount base(all base types)on an electrical backbox which is at RA100Z(A):Remote 3-32 VDC LED annunciator,mounts to a U.S. least 1.5"(3.81 cm)deep.For a chart of compatible junction boxes, single-gang electrical box,for use with B501 and B300-6 bases see SK-61045. only Note:Because of the inherent supervision provided bythe SLC loop, M02-04-00:Test magnet end-of-line resistors are not required.Wiring"T-taps"or branches are permitted for Style 4(Class"B")wiring. M02-09-00:Test magnet with telescoping handle Note:When using relay or sounder bases,consult the SK-ISO CK300:White,detector color kit,pack of 10 installation sheet 156-3627 for device limitations between isolator CK300-IV:Ivory,detector color kit,pack of 10 modules and isolator bases. CK300-BL:Black,detector color kit,pack of 10 PRODUCT LINE INFORMATION SK-HEAT-W:White,low-profile intelligent 135°F fixed thermal sensor SK-HEAT-ROR-W:White,low-profile intelligent rate-of-rise thermal sensor SK-HEAT-HT-W:White,low-profile intelligent 190°F fixed thermal sensor B300-6:White,standard flanged low-profile mounting base B300-6-BP:Bulk pack of B300-6,package contains 10 B300-6-IV:Ivory,standard flanged low-profile mounting base B501-WHITE:White,standard European flangeless mounting base B501-BL:Black,standard European flangeless mounting base B501-IV:Ivory,standard European flangeless mounting base B501-WHITE-BP:Bulk pack of B501-WHITE,contains 10 B200S-WH:White,Intelligent,programmable sounder base B200S-IV:Ivory,Intelligent,programmable sounder base B200SR-WH:White,Intelligent sounder base for retrofit applications B200SR-IV:Ivory,Intelligent sounder base for retrofit applications B200S-LF-WH:White,Low Frequency Intelligent,programmable sounder base B200S-LF-IV:Ivory,Low Frequency Intelligent,programmable sounder base B200SR-LF-WH:White,Low Frequency Intelligent sounder base for retrofit applications Page 2 of 3—351637:B•7/1/2019 SK-HEAT-W SERIES TECHNICAL SPECIFICATIONS • PHYSICAL/ENVIRONMENTAL AGENCY LISTINGS AND Size:2.0"(5.3 cm)high;base determines APPROVALS Silent Knight'and System Sensor"' diameter These listings and approvals apply to the are registered trademarks of moduless ecified in this document.ln some Honeywell International,Inc. -B300-6:6.1"(15.6 cm)diameterp -6501:4"(10.2 cm)diameter cases,certain modules or applications may This document is not intended to be For a complete list of detector bases,see not be listed by certain approval agencies.or used for installation purposes.We listing may be in process.Consult factory for keep SK-61045. try to our product information latest listing status. up-to-date and accurate.We cannot Operating temperature range:SK-HEAT-W, • UL Listed:S6228 cover all specific applications or SK-HEAT-ROR-W:-4°Fto 100°F • FM Approved anticipate all requirements.All (-20°C to 38°C) • CSFM:7270-0559:0511 specifications are subjectto change SK-HEAT-HT-W:-4°F to 150°F(-20°C to without notice. 66°C) Country of origin:Mexico Detector spacing:UL approved for 50 ft. (15.24 m)center to center;FM approved for 25 x 25 ft.(7.62 x 7.62 m)spacing Relative humidity:10%-93%non- condensing Thermal ratings:Fixed-temperature set point 135°F(57°C),rate-of-rise detection 15°F(8.3°C)per minute,high temperature heat 190°F(88°C) ELECTRICAL SPECIFICATIONS Voltage range:15-32 volts DC peak Standby current(max.avg.):200uA @ 24 VDC(one communication every 5 seconds with LED enabled) LED current(max.):4.5mA @ 24 VDC("ON") Honeywell Silent Knight 12 Clintonville Road Northford,CT 06472-1610 Honeywell 203.484.7161 351637 e I 07119 SILENT' www.silentknight.com ©2019 Honeywell International Inc. OaKNIGHT ---.4441111111111 Honeywell ®SILENT KNIHT' SK-DUCT Intelligent Air Duct Smoke Detector The SK-DUCT Intelligent air duct smoke detector is used with SK-PHOTOR (included)for detecting smoke and products of combustion present in air moving through an HVAC air handling system.When smoke is detected in a duct,the unit communicates the condition to the Honeywell Silent Knight _r control panel.The panel,in turn,depending on programming and wiring, turns off fans,blowers,and other devices.The duct housing allows for -r mounting of SK-RELAY addressable relay module. The ModeLSK-DUCT Air Duct Smoke Detector utilizes photoelectric technology for the detection of smoke.It provides early detection of smoke and products of combustion present in air moving through HVAC ducts in SK-DUCT Commercial and Industrial applications. The SK-DUCT is in a heavy duty gray steel back box with a clear cover.It features a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct.It installs quickly and easily. The unit senses smoke in the most challenging conditions,operating in airflow speeds of 100 to 4000 feet per minute,temperatures of-4°F to 158°F,and a humidity range of 0 to 95 percent(non-condensing). FEATURES & BENEFITS • Versatile mounting • Rugged steel back box • Patented sampling options:square or with clear plastic cover tube installs from rectangular • Easy tocLean front or back of the configuration detector with no tools • Large terminal required • New Cover tamper connection screws signal • Available space within • Transparent cover for housing to • LED alarm indication convenient visual accommodate and communication inspection mounting of relay on sensor head module • Detects and limits the • UL listed spread of smoke SK-DUCT Technical Specifications For a complete listing of all PHYSICAL IMPORTANT NOTES: compliance approvals and (Rectangular):14.38"(37 cm)L X 5"(12.7 cm)W X •The use of either RTS151 or RTS151KEY certifications,please visit www.si le n tk n ig ht.c om. 2.5"(6.6 cm)D requires the installation of an accessory coil, (Square):7.75°(19.7cm)L x 9"(22.9cm)W x 2.5'D DCOI L,sold separately.Please refer to the Microsoft.Windows,and (6.35cm) SK-DUCT installation instructions for more the Windows Logo are information registered trademarks Weight:1.6lb(0.73kg) or trademarks of •The RTS151/RTS151KEY test coil circuit Microsoft Corporation. ELECTRICAL(using SK-Photo orSK-PhotoR) requires an external 24VDC power supply which Operating Voltage:15-32 VDC must be LA_listed. Silent Knight',System Sensor'and Honeywell' Standby Current:300 µA @ 24VDC max. ACCESSORY CURRENT LOADS AT 24VDC are registered Alarm Current:6.5 mA @ 24 VDC max(with LED Device Standby Alarm trademarks of Honeywell on) International,Inc. RA100Z OmA 12mA Max. This document is not ENVIRONMENTAL RTS151 OmA 12mA Max intended to be used for Operating Temperature:-4°F-158°F(-20°C- installation purposes.We 70°C) RTS151KEY 12mA 12mA Max try to keep our product Humidity:0%-95%(non-condensing) information up-to date and accurate.We COMPATIBILITY cannot cover all specific AIR VELOCITY The SK-DUCT is compatible with the following applications or anticipate 100 to 4000 ft/min: (0.5-20.3 m/sec.) Honeywell Silent Knight fire alarm control panels: all requirements.All 6820:Addressable fire alarm control panel specifications are subject ORDERING INFORMATION to change without notice. SK DUCT: Intelligent non-relay duct smoke 6820EVS:Addressablefirealarmcontrolpanel with an emergency mass notification system. For Technical Support, detector 6808:Addressable fire alarm control panel call 800 446 6444. SK-PHOTO: Addressable Photo Detector 6700:Addressable fire alarm control panel SK-PHOTOR: Addressable Photo Detector with 5700:Addressable fire alarm control panel remote test capability(included with S'K-Duct) SK-RELAY: Addressable Relay Module,must be 5808:Addressable fire alarm control panel added if relay function is required,(fits in housing) 5820XL:Addressable fire alarm control panel 5820XL-EVS:Addressable fire alarm control panel ACCESSORIES with an emergency mass notification system. DST1: Metal Sampling Tube Duct Width up to l' DST1.5: Metal Sampling Tube Duct Widths l'-2' DST3:Metal Sampling Tube Duct Widths 2'-4' DST5: Metal Sampling Tube DuctWidths4'-8' DST10: Metal Sampling Tube Duct Widths 8'-12' DH4000E-1: Weatherproof Enclosure ETX: Metal ExhaustTube Duct width 1' RA100Z: Remote LED Annunciator DCOIL: Duct accessory coil,required if using with SK-PHOTO and not SK-PHOTOR(included)with SK-DUCT RTS151: Magnetic Remote Test station RTS151KEY: Key-Activated Remote Test station M02-04-O0 Test Magnet P48-21-00 Replacement End Cap for Metal Sampling Tube APA151:Remote annunciator with piezo alarm For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com H K 2 Clinton i Silent dight Honeywell 12 Clintonville Road N o rthfard,CT 06472 Doc 350122 Rev F I uiv ®SILENT' 800-328-0103 G�2017 Honeywell International Inc. KNIGHT Honeywell ® SILENT' KNIGHT SK-PULL-SA / SK-PULL-DA ----14411111119111 Intelligent Pull Stations The SK-PULL-SA is a single action putt station requiring only one motion to IR E activate the station.The SK-PULL-DA is a dual action pull station requiring two motions to active the station.The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel(FACP). PULL 1DOWN1 Extremely easy to operate,the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal.The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. Honeywell INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/O SK-PULL-SA surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13"(5.40 cm)or double gang or 4"(10.61 cm)square electrical box.You can also use the optional(System Sensor®PN BG-TR) trim ring if the station is being semi-flush mounted. PULLPUSHDOWNIN 1 1. r0IIRE oneywell D:'.' :. a SK-PULL-DA /71 FEATURES & BENEFITS • Installer can open • Key operated test and • Meets the Americans • Reliable analog • Handle latches in station without reset lock using lock with Disabilities Act communications for down position and the causing an alarm plate actuator Accessibility trouble-free operation word Activated condition • Key matches Guidelines(ADAAG) • Braille text on station appears,clearly • Dual-color LED is compatible FACP controls and operating handle indicating the station visible through handle locks mechanisms has been pulled guidelines(Section • Rotary address of station blinks green switches •forfast • UL Listed,including • Meets ADA 4.1.3113]) UL 38,Standard of to indicate normal requirement for 5 lbs installation operation and remains maximum pullforceto • Shell,door,and handle Manually Actuated steady red in an alarm active molded from durable Signaling System condition LEXAN' • CSFM Listed • MEA Listed SK-PULL-SA / SK-PULL-DA Technical. Specifications For a complete listing of all compliance approvals and certifications,please visit PHYSICAL ORDERING INFORMATION www.sitentknight.com. Dimensions:5.5"H x 4"W x 1.45"D(14x 10.2 x SK-Pull-SA:Single Action Pull Station 3.7cm) Microsoft,Windows,and SK-Pull-DA:Dual Action Pull Station the Windows Logo are Housing Material:LEXAN polycarbonate resin registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green:Normal BG-TR:Optional trim ring. Microsoft Corporation. Steady Red:Alarm SB-I/O:Surface backbox,indoor/outdoor. Silent Knight'',System Switch:Single pole,single throw(SPST)normally *Unless otherwise noted,specifications apply to Sensor'and Honeywell' open(N/O)switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International,Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage:15-32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current:350µA Knight fire alarm control panels: installation purposes.We 6820:Addressablefirealarmcontrol panel try to keep our product Wire Gauge:Up to 12AWG(3.1 mm2) information up-to 6820EVS:Addressable fire alarm control panel date and accurate.We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature:32°F-120°F(0°C- 6808:Addressable fire alarm control panel applications or anticipate 49°C) 6700:Addressable fire alarm control panel all requirements.All specifications are subject Humidity:10%-93%non-condensing 5700:Addressable fire alarm control panel to change without notice. 5808:Addressable fire alarm control panel rt, 5820XL:Addressable fire alarm control panel call800- 46-644cat 4. ca11800-446-6444. 5820XL-EVS:Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 Doc 3501351 Rev E 111/17 PA SILENT' 800-328-0103 it 2017 Honeywell International Inc. KNIGHT *Th, SYSTEM SENSOR® V. r Indoor Selectable- I : Output Speaker Strobes and Dual Voltage Evacuation Speakers for Ceiling Applications System Sensor L-Series selectable-output speaker strobesAar and dual-voltage evacuation speakers can reduce ground /�► faults and enable faster installation with lower current draw and modern aesthetics. System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a plug-in design and universal Features mounting plate that allow the installer to pre-wire mounting plates, • Plug-in design and protective cover reduce ground faults dress the wires,and confirm wiring continuity before plugging in the speakers.In addition,a protective plastic cover prevents nicked • Universal mounting plate with an onboard shorting spring tests wires by covering exposed speaker components. wiring continuity before installation • No extension ring required These devices also enable faster installations by providing instant • Field selectable candela settings on ceiling units: feedback to ensure that wiring is properly connected,rotary switches 15,30,75,95, 115, 150,and 177 to select voltage and power settings,and 7 field-selectable candela settings for both wall and ceiling speaker strobes. • Automatic selection of 12-or 24-volt operation at 15 and 30 candela The low total harmonic distortion of the SP speaker offers high fidelity • Rotary switch simplifies field selection of speaker voltage(25 sound output while still offering high volume sound output for use in and 70.7 Vrms)and power settings('A,1/2, 1 and 2 watts) high ambient noise applications. • Speakers offer high fidelity and high volume sound output L-Series makes installation easy • 520 Hz+/-10%square wave tone capable with compatible FACP •Attach a universal mounting plate to a 4 x 4 x 2'/e inch back box. • Compatible with System Sensor synchronization protocol Flush-mount applications do not require an extension ring. • Electrical compatibility with existing SpectrAlert and SpectrAlert •Connect the notification appliance circuit or speaker wiring to the Advance products terminals on the mounting plate. •Attach the speaker or speaker strobe to the mounting plate by • Tamper-resistant construction inserting the product tabs into the mounting plate grooves.Hinge • Updated modern aesthetics the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a Agency Listings catch until it is secured with a captured mounting screw. SIGNALING APPROVED I, I LISTED 8404B FM approved except 7320-15530505 for ALERT models 3057493 AVOS866-03•03/23/2018•Pagel L-Series Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21/e-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also,L-Series speaker strobes,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified,unfiltered power supply.Speaker strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,177. Speaker The speaker shall be a System Sensor L-Series model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms.It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor L-Series model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 4'1/16 x 411/16 x 21/a-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Dimensions,Ceiling-Mount Diameter Depth SPC Speaker 6.8 in, 173 mm 1.0 in,25 mm With Surface Mount Back Box 6.9 in, 176 mm 3.5 in,89 mm SPSC Speaker Strobe 6.8 in, 173 mm 2.8 in,73 mm With Surface Mount Back Box 6.9 in, 176 mm 5.37 in, 136 mm *When using 12AWG, 14 AWG,or adding extra wires in the box,a deeper box or extension ring is recommended. Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts(nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC or regulated 24 VDC/FWR''2 Operating Voltage Range(includes fire 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) alarm panels with built in sync) Operating Voltage with MDL3 Sync Module 6.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Frequency Range 400 to 4,000 Hz3 Power VA,Y, 1,2 watts 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 and 30 cd. 3.520 Hz+/-10%square wave tone capable with compatible FACP. AVOS866-03.03/23/2018•Page 2 UL Current Draw Data - UL Max.Strobe Current Draw(mA RMS) 8 to 17.5 Volts 16 to 33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 NA 111 142 95 NA 134 164 115 NA 158 191 150 NA 189 228 177 NA 226 264 Ceiling-Mount Speaker Sound Output Setting UL Reverberant(dBA @10 ft) UL Anechoic(dBA @10 ft) 1/4 W 79 79 1/2 W 82 82 1 W 85 85 2 W 88 88 Ceiling-Mount Speaker Strobe Sound Output Setting UL Reverberant(dBA @10 ft) UL Anechoic(dBA @10 ft) 1/4 W 77 77 1/2 W 80 80 1 W 83 83 2 W 86 86 L-Series Dimensions 68 tl1n. (254 mm) SW mm) (n3 mml ,, 01.111 �: A0543-00 Ceiling Speaker zer• �. (TM (u m;1174.- mm) (TM mm) (44.l mm)+iI eo1OrmMr A/ti ,� : + I A. -m:�1 III4 :... I ATT1`: iMl•� .„,„„ \...„„„„..„,:,,,,, ,,,_,4*,,,,,,.... a , A0544-00 Ceiling Speaker Strobe AVDS666-03•03/23/2018•Page 3 • Surface Mounting 1 i 1` , - - f 11 FA l ° ,,,.6,° Nlitigt� I,Ir o ` ` v:. xx �r.sY 2 7. ii ex \52 - - A0"C4-C I 1, A0520-01 Ceiling Speaker with Surface Mount Back Box Ceiling Speaker Strobe with Surface Mount Back Box °o° , • ,' \lio' o -01'-' ' $)''-.-------' r(i7:•:..,.:',...' 7.,,, A0542-00 Ceiling Speaker Strobe with Trim Ring and 4"Square Electrical Box \,L-Series Ordering Information Ceiling Mount White Red Description SPCWL SPCRL Speaker only SPSCWL SPSCRL Speaker Strobe SPSCWL-P — Plain,Speaker Strobe SPSCWL-SP — Fuego,Speaker Strobe SPSCWL-CLR-ALERT — Alert,Speaker Strobe,Clear Lens Accessories While Red Description SBBCWL SBBCRL Universal Ceiling Surface Mount Back Box TRC-2W TRC-2 Universal Ceiling Trim Ring *� .SYSTEM 3825 Ohio Avenue•St.Charles,IL 60174 02018 System Sensor. SENSOR Q Phone:800-SENSOR2•Fax 630-377-6495 Product specificationsubeouoohangesthou:nouee.Malsysten•ensoroom JE,Y COI• for current product irtormatlon,including the latest version Ibis data sheet. www.systemsensoccom AVDS866-03.03/23/2018 *Th, SYSTEM SENSOR Indoor Selectable- Output Speaker • Strobes and Dual Voltage Evacuation R , 1 •c •;t Speakers for Wall Applications The SpectrAlert Advance selectable output speaker strobes and dual-voltage evacuation speakers can reduce SPECTR9ert ground faults and enable faster installation. Armituy Features The SpectrAlert Advance Series of speakers and speaker • Plug-in design and protective cover reduce ground faults strobes reduce costly ground faults using a plug-in design and universal mounting plate that allow the installer to pre-wire mounting • Universal mounting plate with an onboard shorting spring tests plates, dress the wires,and confirm wiring continuity before plugging wiring continuity before installation in the speakers.In addition,a protective plastic cover prevents • No extension ring required nicked wires by covering exposed speaker components. • Field selectable candela settings: These devices also enable faster installations by providing instant Standard: 15, 15/75,30,75,95, 110, 115 feedback to ensure that wiring is properly connected,rotary switches High: 135, 150, 177, 185 to select voltage and power settings,and 11 field-selectable candela • Automatic selection of 12-or 24-volt operation at 15 settings for both wall and ceiling speaker strobes. and 15/75 candela • Rotary switch simplifies field selection of speaker voltage The low total harmonic distortion of the SP speaker offers high fidelity (25 and 70.7 Vrms)and power settings(1/4,1, 1 and 2 watts) sound output while the SPV speaker offers high volume sound output • SP speakers offer high fidelity sound output for use in high ambient noise applications. • SPV speakers offer high volume sound output SpectrAlert Advance makes installation easy • Compatible with System Sensor synchronization protocol •Attach a universal mounting plate to a 4 x 4 x 21/8 inch back box. Flush-mount applications do not require an extension ring. • Electrical compatibility with existing SpectrAlert products •Connect the notification appliance circuit or speaker wiring to the • Tamper-resistant construction terminals on the mounting plate. • Listed for ceiling or wall mounting •Attach the speaker or speaker strobe to the mounting plate by inserting the product tabs into the mounting plate grooves.Hinge the device into position to lock the product pins into the mounting plate terminals.The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. Agency Listings SIGNALING 0 �� MEA LISTED 111 „�.,E, approved Sa^tP, 7320-1653.201 10-05-E SpectrAlert Advance Speaker and Speaker Strobe Specifications Architectural/Engineering Specifications General SpectrAlert Advance speaker and speaker strobes shall mount to a 4 x 4 x 21/8-inch back box,A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate.Also, SpectrAlert Advance speaker strobes,when used with the Sync•CircuitTM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32°F and 120°F from a regulated DC,or full-wave rectified, unfiltered power supply.Speaker strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115,135, 150, 177, 185. Speaker The speaker shall be a System Sensor SpectrAlert Advance model dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms.It should be listed to UL 1480 and shall be approved for fire protective service.The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F.The speaker shall have power taps and voltage that are selected by rotary switches. Speaker Strobe combination The speaker strobe shall be a System Sensor SpectrAlert Advance model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems.The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch,and shall have a frequency range of 400 to 4,000 Hz.The speaker shall have power taps that are selected by rotary switch.The strobe shall comply with the NFPA 72 requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz.The module shall mount to a 411/16 x 411/16 x 21B-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical Specifications Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non- condensing Dimensions,Wall-Mount Length Width Depth SP Speaker 6 in, 152 mm 5 in,127 mm 2.8 in, 71 mm SPV Speaker 6 in, 152 mm 5 in,127 mm 2.9 in,74 mm With Surface Mount Back Box 6 in, 152 mm 5.1 in,130 mm 3.4 in,86 mm SPS Speaker/Strobe 6 in, 152 mm 5.1 in, 127 mm 4.7 in, 119 mm (including lens and speaker) With Surface Mount Back Box 6 in, 152 mm 5.1 in,130 mm 5.325 in, 135 mm Electrical/Operating Specifications Nominal Voltage(speakers) 25 Volts or 70.7 Volts (nominal) Maximum Supervisory Voltage(speakers) 50 VDC Strobe Flash Rate 1 flash per second Nominal Voltage(strobes) Regulated 12 VDC/ FWR or regulated 24 DC/FWR Operating Voltage Range(includes fire 8 to 17.5 V(12 V alarm panels with built in sync) nominal)or 16 to 33V (24 V nominal) Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33V(24 V nominal) Frequency Range 400 to 4000 Hz Power '/4,Yz, 1,2 watts UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8to17.5Volts 16to33Volts Candela DC FWR DC FWR Standard 15 123 128 66 71 Candela Range 15/75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 Sound Output UL Reverberant(dBA @ 10 ft.) 2W 1W Ys W '/a W Wall-Mount SP Series 86 83 80 77 Wall-Mount SPV Series 90 87 84 81 Wall-Mount SPS Series 85 82 79 76 Wall-Mount SPSV Series 89 86 83 80 Dimensions .97---1.849-- 2.83" 5.00"" 5.00" 1.604_ -�� 1. 1.84= CO M..� c=im === ILL IIU6 men 5.98" ��.�( � 5.97" ::: 11E � -- n =OS L . Wall-Mount SP Speaker Wall-Mount SPS Speaker Strobe • Surface Mounting r�o �II"3 I. MN gio■mmiam---. Ili) ;111: Ip=O ..._. cz= .,,,........, „ :-_, ------, AL. .„,„ ...i.„-s, w..... -........., .... Wall-Mount Speaker Strobe with SBBSPR Surface Mount Back Ordering Infor, ation for SpectrAlert®Advance Speakers and Speaker Strobes Wall Mount White Red Description SPW SPR Speaker only SPWV SPRY Speaker only,High dB SPSW SPSR Speaker Strobe,Standard cd SPSW-P SPSR-P Plain Speaker Strobe,Standard cd SPSW-ALERT — Speaker Strobe,Standard cd,Amber Lens SPSW-CLR-ALERT — Speaker Strobe,Standard cd,Clear Lens SPSWH SPSRH Speaker Strobe,High cd SPSWH-P — Plain Speaker Strobe,High cd SPSWV SPSRV Speaker Strobe,Standard cd,High dB SPSWV-P SPSRV-P Plain Speaker Strobe,Standard cd,High dB Accessories While Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPW SBBSPR Surface Mount Back Box for Speakers and Speaker Strobes TRW TR Wall Mount Trim Ring Notes: All-P models have a plain housing(no"FIRE marking on the cover) "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. "High cd"refers to strobes that include 135,150,177,and 185 candela settings. �� .SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ®215 System Sensor. �� SENSORe Phone:800-SENSOR2•nso 630-377-6495 Product scecilicanona subject to change wend estce.Visitsystemsensoccom for current product inlormaeon,Including the latest version of nls data sheet. wwwsystemsensoccom AVDS11602.2/15 SYSTEM �$ SENSOR"' • Indoor Selectable- Output Strobes ands ` Horn Strobes for Ceiling Applications �' System Sensor L-Series audible visible notification 4,74-4 products are rich with features guaranteed to cut - a installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela • Field-selectable candela settings on ceiling units: The entire L-Series product line of ceiling-mount strobes and horn 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING 0 �► LISTED 85512 FM approved except 7125-16530534 S4011 for ALERT models 7135-1653.0503 3057383 AV5S068-02•12/012017•Page 3 • L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 1' -inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•CircuiP"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Rang& 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVD5868-02•12/O/2017•Page 2 UL Current Draw Data - UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe.Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 75cd 30cd 75cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 75cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVOS868-02•1 2/0112 01 7•Page 3 L-Series Dimensions 2,47"(62.7 mm) 1.3T(34.8 mm) _ = 6.92'dam. 2.5" b 6.83'diam. (175.77 mm) \ (64 mm) (173 mm) i 1 1 r v p Q o\• -�� \• ' ' C 0 ),,s, , 1 III Y } 800 ®8 `III " AC545-00 ACS4C-DO Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box mil - \7 .�� -- S y� i11��1����-� �' ��.. W,pl,aun -'�\ W';: '�iI 7lIA� rpypte" {1NJ1 / ,,££uu bS*, - s Q ® Lille/� ' k 2 �R4� ® ,fit �ry1� , � � � „ti1�i � �D * �i r. %c r- N. Vt, A0494-01 1� ---- A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe.Red SCRL Strobe, Red PC2WL 2-Wire.Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". *� SYSTEM ®201r System Sensor . �� SENSOR 3625 Ohio Avenue•St.Charles, IL 630-377-649560174 Productspepncenonssubiectrochangewithoutn oven, oIysterosenanr.nnm Phone:800-SENSOR2•Fax: for current product information,including me latest version of this data steel. AVDS868-02.12ro1/2017 SYSTEM SENSOR` F — • f Indoor Selectable- E Output Horns, Strobes, and r �� Horn Strobes for Wall Applications a -- SpectrAlerte Advance audible visible notification products SPECTRAriert are rich with features guaranteed to cut installation times __ 5 v fi ti c E and maximize profits. Features The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry. • Plug-in design with minimal intrusion into the back box With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela Like the entire SpectrAlert Advance product line,wall-mount horns, • Field-selectable candela settings on wall units: 15, 15/75, strobes,and horn strobes include a variety of features that increase 30,75.95, 110, 115, 135, 150, 177,and 185 their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring continuity before the device is installed. • Compatible with MDL3 sync module • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING C 0 i MEA filar LISTED APPROVED approved 7125-1853:188(horn strobes,e) 84011(chimes,horn strobes,horns) 3023572 MEA452-05-E chime strcbes( 55512(strobes) 7135-1653:189(hO'ns,chimes) • SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17B-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21B-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data • UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-175 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 St Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions • 2 i• W ■ OD 11111 5.6" i. Wall-mount horn strobes SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes(cont.) P2R 2-Wire Horn Strobe,Standard cd,Red SRH Strobe,High cd,Red P2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SRH-P Strobe, High cd,Red,Plain P2R-SP 2-Wire Horn Strobe,Standard cd,Red,"FUEGO" SRH-SP Strobe, High cd,Red,"FUEGO" P2RH 2-Wire Horn Strobe,High cd,Red SW Strobe,Standard cd,White P2RH-P 2-Wire Horn Strobe,High cd,Red,Plain SW-P Strobe,Standard cd,White,Plain P2W 2-Wire Horn Strobe,Standard cd,White SWH Strobe,High cd,White P2W-P 2-Wire Horn Strobe,Standard cd,White,Plain SWH-P Strobe,High cd,White,Plain P2WH 2-Wire Horn Strobe,High cd,White Horns P2WH-P 2-Wire Horn Strobe,High cd,White, Plain HR Horn,Red P4R 4-Wire Horn Strobe,Standard cd,Red HW Horn,White P4R-P 4-Wire Horn Strobe,Standard cd,Red,Plain Accessories \ P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White SBBR Indoor Surface Mount Back Box,Red \�Y1 Wall Strobes SBBW Indoor Surface Mount Back Box,White SR Strobe,Standard cd,Red SR-P Strobe,Standard cd,Red,Plain SR-SP Strobe,Standard cd,Red,"FUEGO" Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. "High cd"refers to strobes that include 135,150,177,and 185 candela settings. �� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 e2o,6sysremSensor. �� SENSOR Phone 800-SENSOR2•Fax:630-377-6495 Productspecificatanssubject to change wimannotice.vvaitsyslemsensacom for current product information,including the latest version of ens data sheet. www.systemsensor.com AVDS10201.1/16 POWERP...... ....SONIC ���""' TRUSTED B.TTEI SOLLiTITlN5 - • At ,� �I "Orl I'J +' P� ERA' S©NIC ® W V ismdl I nighµg lithiIl III b ,.wnww+v,,,,no.wr ,...• Pu'pwc Lryhtme Smirk; �pE1 pglaTOf' ,,,, M 12 v n+^'v�" 1-,. .py ss .ama liti ss" I5-1 270 FEATURES 12V 7.0 AH @ 20-hr. • Absorbent Glass Mat(AGM)technology for 12V 6.5 AH @ 10-hr. superior performance Rechargeable Sealed Lead Acid Battery • Valve regulated,maintenance free spill proof construction PS - General Purpose Series • Power/volume ratio yielding excellent energy density TERMINALS:(mil) • Rugged vibration and impact resistant ABS case and cover F1: Quick disconnect tabs, F2: Quick disconnect tabs, 0.187"x 0.032'-Mate with 0.250"x 0.032"-Mate with • Gas recombination technology AMP INC.FASTON"187'series AMP INC FASTON'250"series • 5 year design life -1 `+-2.5 -7-1--•1 �z.s ��I� APPROVALS N`N OR 3.2 i � ... • Approved for transport by air.D.O.T.,I.A.T.A.,F.A.A. .-e.35-. , 3'4 �� I and C.A.B.certified 1-7.95---♦ - co0 �m • U.L.recognized Torque-Not Applicable Torque-Not Applicable • IS09001:2015-Quality management systems DIMENSIONS:inch(min) PERFORMANCE SPECIFICATIONS L: 5.95(151) Nominal Voltage 12 volts(6 cells) W: 2.56(65) ® H: 3.70(94) Nominal Capacity W HT:3.86(98) 20-hr. (350mA to 10.50 volts) 7.00 AH Tolerances are+/-0.04 in. 10-hr. (650mA to 10.50 volts) 6.50 AH (+/-imm)and eight 8 in. 5-hr. (1.2A to 10.20 volts) 6.00 AH dimensio for height dimensions.All data subject 1-hr. (4.5A to 9.00 volts) 4.50 AH to change without notice. Approximate Weight 4.80 lbs.(2.18 kg) � I I� ___.. tltlI�, Internal Resistance(approx.) 23.0 milliohms _^Y" WEiRFJ�� Max Short-Duration Discharge Current(10 Sec.) 70.0 amperes MODEL vsPi27o Fi llll IEW HT H ap Fir Shelf Life(%of nominal capacity at 68°F(20°C) 1 Month 97% " ". - 3 Month 91% E:i- 6 Month 83% FL H Operating Temperature Range Charge 5°F(-15°C)to 122°F(50°C) I Discharge -4°F(-20°C)to 140°F(60'C) CORPORATE HEADQUARTERS POWER-SONIC EUROPE LIMITED C8S8 ABS Plastic (USA AND INTERNATIONAL E%CLUDINS EMEA) (EMEA-EUROPE,MHDLE EAST AND AFRICA) PSC-12B00A-C Power-Sonic Corporation 3 Buckingham Square, Power Sonic Chargers 7550 Panasonic Way,San Diego, Hurricane Way,Wickford, PSC-121000-PC California 92154 Essex SS11 8YQ T: +1(619)661 2020 T: +44(0)1268 560686 F: +1(619)661 3650 F: +44(0)1268 560902 E: customer-service@power-sonic.com E: salesEMEA@power-sonlc.com To ensure safe and efficient operation always refer to the latest edition of nor Technical Manual as published on oor websde. C 2018.Power-Sonic Corporation.All rights reserved.Al trademarks mete property of their respective owners. �OS•/ M-CO!1I fS•f�OM All data subject to change without notice.ESO E h/ 1r 1 J 11 y y all 61.1 POWER ' 1 � H H CL PS-1210 12V 6.5 AH @10-hr. Rechargeable Sealed Lead Acid Battery PS - General Purpose Series SHELF LIFE Si STORAGE LIFE CHARACTERISTICS IN STAND-BY USE 100 Chews srct Ambient Tem peratu re 20°C(68°F) necessary Neae 100 o is requirerd.u 8 80 0 S°C Charging before use is necessary 60 p (41°F) to help recover Mlcapacity. Float Charging Voltage y 60 40 2.25-2.30 V/Cell m 20 40°C 30°C 20°C 'g 40 (104°F)—(86°F) (60°F) 0 a r I 0 1 2 3 4 5 V 0 Years 0 2 4 6 8 10 12 14 16 18 20 Standing Period(Months) CHARGING CHARGERS Cycle Applications:Apply constant voltage charge at Power Sonic offers a wide range of chargers suitable 2.35v/c-2.45v/c(14.1 -14.7v for 12v Monobloc)at 20°C. for batteries with a variety of capacities. Initial charging current should be set at less than 0.25C Please refer to our website for more information on Amps.Switch to float charge to avoid overcharging. our switch mode and transformer type chargers. "Float"or"Stand-By"Service:Apply constant voltage Please contact our technical department for advice if charge of 2.25v/c-2.30v/c(13.5 to 13.8 volts for 12v you have difficulty in locating a suitable charger. Monobloc at 20°C.When held at this voltage,the battery will seek its own current level and maintain itself in a fully charged condition. FURTHER INFORMATION Temperature Compensation:Charging Voltage for both Please refer to our website www.power-sonic.com Cyclic and Standby applications should be regulated in for a complete range of useful downloads,such as relation to ambient temperature.As temperature rises product catalogs,material safety data sheets(MSDS), charging voltage should be reduced to prevent overcharge ISO certification,etc. and increased as temperature falls to avoid undercharge. For further charging information including temperature compensation factors,see Power Sonic Technical Manual/ ow- Power Sonic Charger specifications. APPLICATIONS — " wale • General purpose • Medical eella" • Emergency lighting • Fire and security . , y/ER'• S©NC rdOOEi PS-12/0 F1•v fYN" IOTrM Hr CORPORATE HEADQUARTERS POWER-SONIC EUROPE LIMITED • ,e"« (USA AND INTERNATIONAL IXCWDIND EMEA) (EMEA-EUROPE,MIDDLE EAST AND AFRICAI "`'.-... Power-Sonic Corporation 3 Buckingham Square, 7550 Panasonic Way,San Diego, Hurricane Way,Wickford, California 92154 Essex SS11 8YQ T: +1(619)661 2020 T: +44(0)1268 560686 F: +1(619)661 3650 F: +44(0)1268 560902 E: customer-service@power-sonic.com E: salesEMEA@power-sonic.com To ensure safe and efficient operation always refer to the lelest edition of our Technical Manual,as published en ourwebaite. 02018.Power-Sonic Corporation.NI rights reserved.All trademarks are the property of their respective owners. OW �� O I - O MI data subject to change without nMlee.280.E ° W POWERp W SONIC rn N) i THLII:TrD PAULI., I I".'I:. IL PS-��/ 0 12V7.0 6A @10-hr. hEI ' 12V .5 AN @ 10-hr. 171F "'�� Rechargeable Sealed Lead Acid Battery MAY 0 6 2020 PS — General Purpose Series SHELF LIFE&STORAGE CITY r LIFE CHARACTERISTICS IN STAND-BY USE r3t.ils_Ol('.'Di* 100 Charging isnot Ambient Temperature 20°C(68°F) v necessary uNess 100 100%of is rertuifrd capacity BD ',1 AI r: m 80 Charging before lZ 5°C use isneasaary c (41°F)- to help reower 60 NU capacity. Float Charging Voltage c 60 s. 40 - 2.25-2.30 V/Cell r 40°C 30°C 20°C 20 o 40 (104°F)—(86°F)_(68°F) 0 5 RECEIVED p-.�- 1'-�` A OT I 0 1 2 3 Ee, L. V 0 2 4 6 8 10 12 14 16 18 20 Years Standing Period(Months) MAY 6 2020 CHARGING CHARGERS CITY OF TiGARD Cycle Applications:Apply constant voltage charge at Power Sonic offers a wide range of clblikkerS145V*ISION 2.35v/c-2.45v/c(14.1 -14.7v for 12v Monobloc)at 20°C. for batteries with a variety of capacities. Initial charging current should be set at less than 0.25C Please refer to our website for more information on Amps.Switch to float charge to avoid overcharging. our switch mode and transformer type chargers. "Float"or"Stand-By"Service:Apply constant voltage Please contact our technical department for advice if charge of 2.25v/c-2.30v/c(13.5 to 13.8 volts for 12v you have difficulty in locating a suitable charger. Monobloc at 20°C.When held at this voltage,the battery will seek its own current level and maintain itself in a fully FURTHER INFORMATION charged condition. Temperature Compensation:Charging Voltage for both Please refer to our website www.power-sonic.com Cyclic and Standby applications should be regulated in for a complete range of useful downloads,such as relation to ambient temperature.As temperature rises product catalogs,material safety data sheets(MSDS), charging voltage should be reduced to prevent overcharge ISO certification,etc. and increased as temperature falls to avoid undercharge. For mfurther nsa ion charging oisfsee oon including temperature compensation factors,see Power Sonic Technical Manual/ Power Sonic Charger specifications. APPLICATIONS llrill".1.4 • General purpose Medical• Emergency lighting • Fire and security r.CORPORATE HEADQUARTERS POWER-SONIC EUROPE LIMITED _- 15 (USA AND III1ERNA1IONAL!XWJIING EMUS) (USES-EUROPE,MIME EAST AIIO AFRICA) Power-Sonic Corporation 3 Buckingham Square, 7550 Panasonic Way,San Diego, Hurricane Way,Wickford, California 92154 Essex SS11 BYO T: +1(619)661 2020 T: +44(0)1268 560686 F: +1(619)661 3650 F: +44(0)1268 560902 E: customer-service@power•sonic.com E salesEMEA@power-sonic.com To ensue safe and efficient operation always refs to the latest edition of our Technical Manual as published on our website.02018.Power-Sonic Corporation.Alld rights reserved.All trademarks are the property oftheir respective owners. �OWCIy�SOI n IIC°CO111�y� Al data subject to change without notice.E&01