Loading...
Report (2) HardiePlank` I ..� R C !V D Sleek and strong, HardiePlank°lap Apk 1 C GQ 1 siding is not just our best-selling `i ARD product—it's the most popular brand a t L.21VISjt"t!y of siding in America. „„- ,;.; With a full spectrum of colors and ' 4; , gat �rrUEr textures,homeowners can enjoy -.*1 .,,, protection from the elements and the versatility to make their dream home a reality.From Victorians to Colonials, i' � �imigtOgi HardiePlank lap siding sets the 4. standard in exterior cladding. 1 _,,`*.. Illiellgt,, \.. .Q HardiePlanle N Lap Siding Select Cedarmill° Khaki Brown `" 74 ,4, .,,,.. ......, 1 ., t r"--k"."-*-k---""------------------..• , ,.......... it A classic look for THE HOME OF THEIR DREAMS. SELECT CEDARMILL°&SMOOTH HardiePlank Width 5.25 in 6.25 in 7.25 in 8.25 in 9.25 in 12 in` Thickness 5/16 in Exposure 4 in 5 in 6 in 7 in 8 in 10.75 in Length 12 It planks Prime Pcs/Pallet 360 308 252 230 190 152 ColorPlus Pcs/Pallet 324 280 252 210 - - Pcs/Sq 25.0 20.0 16.7 14.3 12.5 9.3 SELECT CEDARMILL SELECT CEDARMILL Width 5.25 in 6.25 in 7.25 in 8.25 in 9.25 in 12 in* STATEMENT ✓ COLLECTION'" DREAM ✓ V V V COLLECTION'" PRIME ✓ V V V V V SMOOTH SMOOTH Width 5.25 in 6.25 in 7.25 in 8.25 in 9.25 in 12 in' STATEMENT COLLECTION" DREAM V V V COLLECTION"' PRIME ✓ V V V V V HZ5'planks feature a drip edge.9.25 in and 12 in widths in do not feature the drip edge BEADED CEDARMILL' BEADED SMOOTH BEADED CEDARMILLm&BEADED SMOOTH Width 8.25 in STATEMENT Exposure 7 in COLLECTION" Prime Pcs/Pallet 240 DREAM ✓ COLLECTION"' ColorPlus PcslPallet 210 PRIME V Pcs/Sq 14.3 COLONIAL ROUGHSAWN COLONIAL SMOOTH COLONIAL ROUGHSAWN"& COLONIAL SMOOTH Width 8 in STATEMENT -4114124111*11 - Exposure 6.75 in COLLECTION'" Prime Pcs/Pallet 240 DREAM V ColorPlus Pcs/Pallet 240 COLLECTION'" F _ ILPcs/Sq 14.9 PRIME V RUSTIC CEDAR RUSTIC CEDAR Width 6.25 in 8.25 in STATEMENT '- Exposure 5 in 7 in COLLECTION"" Prime Pcs/Pallet 308 240 DREAM :' ColorPlus Pcs/Pallet - COLLECTION'" _" ,# .; , ..� ``` Pcs/Sq 20 14.3 PRIME V 13 * N �� RECE ,V ' lifir APR 1 20 (� HardiePlank' Lap Siding .. 41,14WI . litI�u�i+�Q�jvjcnr EFFECTIVE DECEMBER 2019 IMPORTANT:FAILURE TO FOLLOW JAMES HARDIE WRITTEN INSTALLATION INSTRUCTIONS AND COMPLY WITH APPLICABLE BUILDING CODES MAY VIOLATE LOCAL LAWS,AFFECT BUILDING ENVELOPE PERFORMANCE AND MAY AFFECT WARRANTY COVERAGE.FAILURE TO COMPLY WITH ALL HEALTH AND SAFETY REGULATIONS WHEN CUTTING AND INSTALLING THIS PRODUCT MAY RESULT IN PERSONAL INJURY.BEFORE INSTALLATION,CONFIRM YOU ME USING THE CORRECT HARDIEZONE°PRODUCT INSTRUCTIONS BY VISITING HARDIEZONE.COM OR CALL 1-866-942-7343(866-9-HARDIE) © CUTTING INSTRUCTIONS STORAGE& HANDLING: OUTDOORS INDOORS 1.Position cutting station so that airflow blows dust away from the DO NOT grind or cut with a power saw indoors.Cut using shears(manual,pneumatic or Store flat and keep dry and covered prior to user and others near the cutting area. electric)or the score and snap method,not recommended for products thicker than 7/16 in. installation.Installing siding wet or saturated may 2.Cut using one of the following methods: result in shrinkage at butt joints.Carry planks on a.Best: Circular saw equipped with a HardieBlades saw blade and attached vacuum dust collection system.Shears - DO NOT dry sweep dust;use wet dust suppression or vacuum to collect dust. edge. Protect edges and corners from breakage. (manual,pneumatic or electric)may also be used,not - For maximum dust reduction,James Hardie recommends using the"Best"cutting James Hardie Is not responsible for damage caused recommended far products thicker than 7/16 in. practices.Always foNow the equipment manufacturer's instructions for proper operation. by improper storage and b.Better: Circular saw equipped with a dust collection feature - For best performance when cutting with a circular saw,James Hardie recommends handling of the c.Goad: Circular saw equipped witha(e.g.Roanesaw)and a Har Har de saw blade.tllettlade saw blade. using HardieBladeo saw blades. a Har product. ;� - - Go to jameshardiepros.com for additional cutting and dust control recommendations, _ IMPORTANT:The Occupational Safety and Health Administration(OSHA)regulates workplace exposure to silica dust. For construction sites,OSHA has deemed that cutting fiber cement with a circular saw having a blade diameter less than 8 inches and connected to a commercially available dust collection system per manufacturer's instructions results in exposures below the OSHA Permissible Exposure Limit(FEL)for respirable crystalline silica,without the need for additional respiratory protection. If you are unsure about how to comply with OSHA silica dust regulations,consult a qualified industrial hygienist or safety professional,or contact your James Hardie technical sales representative for assistance.James Hardie makes no representation or warranty that adopting a particular cutting practice will assure your compliance with OSHA rules or other applicable laws and safety requirements. GENERAL REQUIREMENTS: • HardiePlank®lap siding can be installed over braced wood or steel studs,20 gauge(33 mils)minimum to 16 gauge(54 mils)maximum,spaced a maximum of 24 in o.c.or directly to minimum 7/16 in thick OSB sheathing.See General Fastening Requirements.Irregularities in framing and sheathing can mirror through the finished application.Correct irregularities before installing siding. • Information on installing James Hardie products over non-nailable substrates(ex:gypsum,foam,etc.)can be located in JH Tech Bulletin 19 at www.jamehardie.com • A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration.James Hardie does manufacture HardieWrape Weather Barrier,a non-woven non-perforated housewrap',which complies with building code requirements. • When installing James Hardie products all clearance details in figs.3-14 must be followed. Double Wall Figure 1 Single Wall • Adjacent finished grade must slope away from the building in accordance with local building codes-typically a minimum Construction Construction of 6 in.in the first 10 ft.. water-resistive let-in bracing • Do not use HardiePlank lap siding in Fascia or Trim applications. barrier plywood or 24 in.o.c.max. • Do not install James Hardie products,such that they may remain in contact with standing water. OSB sheathing rr • HardiePlank lap siding may be installed on flat vertical wall applications only. ''i .��I� • For larger projects,including commercial and multi-family projects,where the span of the wall is significant in length,the designer and/or architect should take Into consideration the coefficient of thermal expansion and I� �I moisture movement of the product in their design.These values can be found in the Technical Bulletin"Expansion Characteristics es of James Hardie®rivide installation/wind at www.load information sli •James Hardie Building Products provides installation/wind load information for buildings with a maximum mean roof height of 85 feet For information on installations above 60 feet,please contact JH technical support. INSTALLATION: JOINT TREATMENT Figure 2 One or more of the following joint treatment options are stud Nail line(If nail line is not / required by code(as referenced 2009IRC R703.10.2) present,place fastener A.Joint Hashing(James Hardie recommended) �,'V.ltll between 3/4 in.&1 in. water-resistive B.Caulking*(Caulking is not recommended wgter- r404from top of plank) barrier for ColorPlus for aesthetic reasons as the Caulkingresistive harrier Nail 3/8 in.from 4 fastener and ColorPlus will weather ' edge of plank joint - Install a 1 1/4in.starter stripto differently.For the same reason, flashing ; Leave appropriate gap between ensure a consistent plank angle do not caulk nail heads on Install planks in planks and trim,then caulk.' ColorPlus products.) I moderate contact at buff joints C."H" jointer cover ® JamesHardie Note:Field painting over caulking may produce a sheen difference when compared to the field painted PrimePlus.`Refer to Caulking section in these instructions. 'For additional information on HardieWrap®Weather Barrier,consult James Hardie at 1-866-4Hardie or www.hardiewrap.com SELECT CEDARMILL° I SMOOTH I BEADED CEDARMILL° I BEADED SMOOTH I CUSTOM COLONIAL SMOOTH° I CUSTOM COLONIAL—ROUGHSAWN Visit jameshardiepros.com for the most recent version. HS11119 P1/4 12/19 kNZ NardiePlane Lap Siding CLEARANCE AND FLASHING REQUIREMENTS Figure 3 Figure 4 Figure 5 Figure 6 Roof to Wall Horizontal Flashing Kickout Flashing Slabs,Path, Steps to Siding i iimn---- Z-Flashing T �® As required i bylRCcode �� �� l��,y�mm4in.x 4la Min.not in. `� ��kk !1: Do caulk. . Alk in. '�, �. 1n. r I,� Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Deck to Wall Ground to Siding Gutter to Siding Sheltered Areas Mortar/Masonry JN 4 V -- _ y =Flashing Z-flashing Z-Fla hing _ `_ Z-Fleshing in.t Min.1/4 in. r4/---' in. 6 in. 1: �, rt ��r in.IA Min.1/2 in. Figure 12 Figure 13 Figure 14 Drip Edge Block Penetration Valley/Shingle Extension 'ecommended in HZ10 �� fi'r� - Extejulshingles in•Y4 it at le 1 in.out''. `�' 1i , Caulk Iroutthefascia �� I� when gutters r are nt FASTENER REQUIREMENTS* I Refer to the applicable ESR report online to determine which fastener meets your wind load design criteria. Blind Nailing is the preferred method of installation for HardiePlanke lap siding products.Face nailing should only be used where required by code for high wind areas and must not be used in conjunction with Blind nailing(Please see JH Tech bulletin 17 for exemption when doing a repair). BLIND NAILING FACE NAILING Nails-Wood Framing Nails-Waod Framing09 •6d(0.113 in.shank x 0.267 in.HD x 2 in.long) •Siding o nail ng(0 nail in.(0.1212 in.s.shank in.HD x 2.H long) •Siding nail(0.09"shank x 0.221"HD x 2"long) •11 ga.roofing x 0.371 in.HD x 1.25 in.long) Screws-Steel Framing Screws-Steel Framing •Ribbed Wafer-head or equivalent(No.8 x 1 1/4 in.long •Ribbed Bugle-head or equivalent(No.8-18 x 1-5/8 in.long x x 0.375 in.HD)Screws must penetrate 3 threads into metal framing. 0.323 in.HD)Screws must penetrate 3 threads into metal framing, Nails-Steel Framing Nails-Steel Framing •ET&F Panelfasi•nails or equivalent(0.10 in.shank x 0.313 in.HD x 1-1/2 in.long) •ET&F pin or equivalent(0.10 in.shank x 0.25 in.HD x 1-1/2 in.long) Nails must penetrate minimum 1/4 in.into metal framing. Nails must penetrate minimum 1/4 in.into metal framing. OSB minimum 7/16 in. OSB minimum 7/16 in. I *Siding nail(0.09 in.shank x 0.215 in.HD x 1-1/2 in.long •Siding nail(0.09 in.shank x 0.221 in.HD x 1-1/2 in.long) •Ribbed Wafer-head or equivalent(No.8 x 1 5/8 in,long x 0.375 in.HD). 'Also see General Fastening Requirements;and when considering attemative fastening options refer to James Hardie's Technical Bulletin USTB 5-Fastening Tips for HardiePlank Lap Siding. H511119 P2/4 12/19 4,tii ij;� HardiePlank®Lap Siding FASTENER REQUIREMENTS continued 24• -- Figure 15 Figure 16 St d — 0.C.max Stud 24' ---. iII11i4lilli1i11 O.C.max ----- Joint low 1 114"min. y- - Minimum overlap Flashing �4m' P :+r" for Both Face •�"� i T,_rr—'r• 1 and Blind Nailing I w"•1 r - - — _ Nail Line rf ; �' 7r _3/4"- 1 / c Blind Nail min.1 1/4 in. �� overlap II Face Nail } ; r j Water Resistive II Water Resistive Berner 1 1/4-min. Barrier Overlap Laminate sheet to be removed immediately after installation of each course for ColorPlus®products. IPin-backed corners may be done for aesthetic purposes only.Finish nails are recommended for pin-backs.Headed siding nails are allowed.Place pin-backs no closer than 1 in.from plank ends and 3/4 in.from plank edge into min.3/8 in.wood structural panel.Pin-backs are not a substitute for blind or face nailing. GENERAL FASTENING REQUIREMENTS PNEUMATIC FASTENING Fasteners must be corrosion resistant,galvanized,or stainless steel.Electro-galvanized James Hardie products can be hand nailed or fastened with a pneumatic tool. are acceptable but may exhibit premature corrosion. James Hardie recommends the Pneumatic fastening is highly recommended. Set air pressure so that the use of quality,hot-dipped galvanized nails.James Hardie is not responsible for the fastener is driven snug with the surface of the siding.A flush mount corrosion resistance of fasteners.Stainless steel fasteners are recommended when attachment on the pneumatic tool is recommended. This will help control the installing James Hardie®products near the ocean,large bodies of water,or in very depth the nail is driven.If setting the nail depth humid climates. proves difficult,choose a setting that under drives Manufacturers of ACO and CA preservative-treated wood recommend spacer materials \�-�J the nail. (Drive under driven nails snug with a or other physical barriers toprevent direct contact of ACO or CApreservative-treated smootha faced steel amammer- g).Do not apply for P Y SNUG FLUSH installation to steel framing). wood and aluminum products.Fasteners used to attach HardieTrim Tabs to preserva- tive-treated wood shall be of hot dipped zinc-coated galvanized steel or stainless steel and in accordance to 2009 IRC R317.3 or 2009 IBC 2304.9.5 DO NOT DO NOT DO NOT USE • Consult applicable product evaluation or listing for correct fasteners type and l% lk placement to achieve specified design wind loads. %Or 1ST tva� • NOTE:Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction.Consult James Hardie Technical Services if you are UNDER OVER SLANT ALUMINUM unsure of applicable compliance documentation. DRIVE DRIVE FASTENERS • Drive fasteners perpendicular to siding and framing. • Fastener heads should fit snug against siding(no air space). IF,THEN IF,THEN ADDITIONAL NAIL •NOTE:Whenever a structural member is present,HardiePlank should be fastened with even spacing to the structural member.The tables allowing direct to OSB or plywood WOOD STEEL FACE CLIPPED should only be used when traditional framing is not available. FRAME FRAME NAIL HEAL NAILS CUT EDGE TREATMENT r Caulk,paint or prime all field cut edges.James Hardie touch-up kits are required tom P ` touch-up ColorPlus products. COUNTERSINK STAPLES CAULKING HAMMER &Rtt FLUSH For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, REMOVE& Class 25 or higher or a Latex Joint Sealant complying with ASTM C834.Caulking/Sealant REPLACE must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note:some caulking manufacturers do not allow"tooling". PAINTING DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardiee Products.Factory-primed James Hardie products must be painted within 180 days of installation. 100%acrylic topcoats are recommended.Do not paint when wet.For application rates refer to paint manufacturers specifications.Back-rolling is recommended if the siding is sprayed. HS11119 P3/4 12/19 V • f Vy �o 4i7ly�_ HardiePlank°Lap Siding T COLORPLUS®TECHNOLOGY CAULKING,TOUCH-UP&LAMINATE •Care should be taken when handling and cutting James Hardie®ColorPlus®products.During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product,then rinse with a garden hose. •Touch up nicks,scrapes and nail heads using the ColorPlus®Technology touch-up applicator.Touch-up should be used sparingly. If large areas require touch-up,replace the damaged area with new HardiePlank®lap siding with ColorPlus®Technology. •Laminate sheet must be removed immediately after installation of each course. •Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPlus®product dealer. •Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your ColorPlus product dealer. Note:James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be covered under the James Hardie ColorPlus Limited Finish Warranty. PAINTING JAMES HARDIE®SIDING AND TRIM PRODUCTS WITH COLORPLUS®TECHNOLOGY When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application: • Ensure the surface is clean,dry,and free of any dust,dirt,or mildew • Repriming is normally not necessary •100%acrylic topcoats are recommended • DO NOT use stain,oil/alkyd base paint,or powder coating on James Hardie®Products. • Apply finish coat in accordance with paint manufacturers written instructions regarding coverage,application methods,and application temperature • DO NOT caulk nail heads when using ColorPlus products,refer to the ColorPlus touch-up section COVERAGE CHART/ESTIMATING GUIDE Number of 12 ft.planks,does not include waste • • COVERAGE AREA LESS( NINGS 51/4 6173 RDIEP/11AI1K"t.itf SIDIN%WIDTH 81/4 91/4 91/2 12 (150.100 sq.ft.) (exposure) 4 5 6 61/4 6 3/4 7 8 81/4 10 3/4 ` 1 25 20 17 16 15 14 13 13 9 . 2 50 40 33 32 30 29 25 25 19 3 75 60 50 48 44 43 38 38 28 4 100 80 67 64 59 57 50 50 37 5 125 100 83 80 74 71 63 63 47 6 150 120 100 96 89 86 75 75 56 7 175 140 117 112 104 100 88 88 65 8 200 160 133 128 119 114 100 100 74 9 225 180 150 144 133 129 113 113 84 10 250 200 167 160 148 143 125 125 93 11 275 220 183 176 163 157 138 138 102 12 300 240 200 192 178 171 150 150 112 13 325 260 217 208 193 186 163 163 121 ' 14 350 280 233 224 207 200 175 175 130 15 375 300 250 240 222 214 188 188 140 16 400 320 267 256 237 229 200 200 149 17 425 340 283 272 252 243 213 213 158 18 450 360 300 288 267 257 225 225 167 19 475 380 317 304 281 271 238 238 177 20 500 400 333 320 296 286 250 250 186 This coverage chart is meant as a guide.Actual usage is subject to variables such as building design.James Hardie does not assume responsibility for over or under ordering of product. HS11119 P4/4 12/19 0 GANGER:May cause cancer if dust from product is inhaled.Causes damage to lungs and respiratory system through prolonged or repeated inhalation of dust train product.Refer to the current product Safely Data Sheet before use. The hazard associated with fiber cement arises from crystalline silica present in the dust generated by activities such as cutting,machining,drilling,routing,sawing,crushing,or otherwise abrading fiber cement,and when cleaning up,disposing of or moving the dust.When doing any of these activities in a manner that generates dust you must(1)comply with the OSHA standard for silica dust and/or other applicable law,(2)follow James Hardie cutting instructions to reduce or limit the release of dust;(3)warn others in the area to avoid breathing the dust;(4)when using mechanical saw or high speed cutting tools,work outdoors and use dust collection equipment;and(5)if no other dust controls are available,wear a dust mask or respirator that meets NIOSH requirements(e.g.N-95 dust mask).During clean-up,use a well maintained vacuum and fitter appropriate for capturing tine(respirable)duster use wet clean-up methods-never dry sweep. A WARNING:This product can expose you to chemicals including respirable crystalline silica,which is known to the State of California to cause cancer.For more information go to P65Warnings.ca.905. RECOGNITION:I In accordance with ICC-ES Evaluation Report ESR-2290,HardiePlank®lap siding is recognized as a suitable alternate to that specified in the 2006,2009,2012&2015 International Residential Code for One and Two-Family Dwellings,and the 2000,2009,2012&2015 International Building Code.HardiePlank lap siding is also recognized for application in the following:City of Los Angeles Research Report No.24862,State of Florida Product Approval FL#13192, Miami-Dade County Florida NOA No.17-0406.06,U.S.Dept.of HUD Materials Release 1263f,Texas Department of Insurance Product Evaluation EC-23,City of New York MEA 223-93-M,sad California OSA PA-019.These documents should also be corsubed for additional information concerning the suitability of this product for specific applications. 0 2018 James Hardie Building Products,Inc MI rights reserved TM,SM and® Product warranties,safety information and additional inslellalien I® Ja mesHardie denote trademarks or registered trademarks of James Hardie Technology Limited. information are evadable at lameshardiepros.com