Report (2) Mecz026 - c /3 i/73y SR) 72 '6/Jac RECEIVED APR 09 2020 CITY OF TIGARD FlUILDING DIVISION °Irl Jacobs Heating and Air Conditioning Inc. Submittal Packet 72' Ave Apts - RETAIL TI Salon WO# 50746.005 Opp,/o b TABLE OF CONTENTS Job Name: 72nd Ave Apts Job No. 50746 Submittal Packet DESCRIPTION Section Tab Carrier PerformanceTM Multi-Zone Heat Pump with Basepan Heater Model: 38MGRQ18B- -3 HP-3 1 Carrier PerformanceTM High Wall Indoor Unit Model: 40MAQB09B- -3 FC-3A & 3B 2 Refco Gobi II Condensate Pump Model: 3004045 Cond. Pump 3 Markel®HotPod Duct Mounted Heater Model: HP8-1440120-2T SF-1 4 Broan®FLEX Series Single-Speed Bathroom Exhaust Fan Model: A110 EF-1 &2 5 HEATING &AIR CONDITIONING TAB 1 gocog Outdoor Unit Multi-zone Heat Pump Ductless System Outdoor Model 38MGRQ18B--3 Submittal Data Job Data: Location: Buyer: Buyer P.O.#:I Carrier* Unit Number: Model Number: Performance Data Certified By: Date: It 1 � MULTI-ZONE STANDARD FEATURES h 111{ Features Outdoor: •Connect 2,multiple style indoor units •���� - - High Wall �a���,` '' °' Cassette /1/0,`0 a ' {lr �' Ducted ll i(f !r!MOW i�1 (� � Console *V. s" /1 •Variable Speed(Inverteri Compressor f/ •Qui e op Heater factory installed •Quiet operation •Aluminum Golden Hydrophilic pre-coated fins Cooling operating range-13°-122°F(-25°-50°C) • Heating operating range-22 -86°F(-30°-30°C) LIMITED WARRANTY* •10 year limited to original purchaser on compressor and parts upon timely registration,otherwise 5 years *For residential applications.See warranty for full details. Compatibility Table For matched compatibility see Product Data INDOOR UNIT 40MPHAQ09XA3 619PHAQ09XA3 DHMPHAQ09XA3 PHASED OUT 40MPHAQ12XA3 619PHAQ12XA3 DHMPHAQ12XA3 INDOOR UNITS High Wall 4OMAQB09B--3 619PE0009BBMA DHMSHAQ09XA3 40MAQB12B--3 619PEQ012BBMA DHMSHAQ12XA3 40MHH409---3 40MHHQ12---3 Cassette 40MBQB09C--3 619RE0009CBMA 40MBCQ09---3 40MBQB12C--3 619RE0012CBMA 40MBCQ12---3 Ducted 40MBQB09D--3 619RE0009DBMA 40MBDQ09---3 40MBQB12D--3 61 9REQ012DBMA 40MBDQ12--3 Console - 40MBQB09F--3 619RE0009FBMA 40MBFQ09--3 40MBQB12F--3 61 9REQ012FBMA 40MBFQ12--3 Copyright 2019 CACIBDP•Atlanta,GA 30339 Edition Date:11/2019 Catalog No:38MGR-113-04SB SUBJECT TO CHANGE WITHOUT NOTICE Page 1 Replaces:38MGR-18-03SB Specifications Size 18 Coding Outdoor DB Min- °F(°C) -13-122(-25-50) Operating Max System Outdoor Model 38MGRQ188--3 Range Heating Outdoor DB Min- °F(°C) -22-86(-30-30) Max Max Number of Zones 2 Total Piping Length ft(m) 131(40) Energy Star YES Piping to furthest FCU ft(m) 82(25) Cooling System Tons 1.5 Drop(OD above ID) ft(m) 49(15) Cooling Rated Capacity Btu/h 18,000 Piping Lift(OD below ID) ft(m) 49(15) Cooling Cap.Range Min-Max Btu/h 5,810-21,940 Pipe Connection Size- in(mm) 1/4`2(6.35°2) Liquid SEER 22 5 Pipe Connection Size- in(mm) 3/8*2(9.52`2) Performance Suction Non-Ducted EER 12.5 Type R410A Heating Rated Capacity (47°F) Btu/h 19,000 Refrigerant Charge I lbs(kg) 4.41(2.0) Heating Maximum Capacity (5°F) Btu/h 14,400 Metering Device EEV Heating Cap.Range Min-Max Btu/h 5,760-24,480 Voltage,Phase,Cycle I V/Ph/Hz 208/230-1-60 HSPF 10.3 Power Supply Indoor unit powered Electrical from outdoor unit COP(47°F) W/W 3.6 MCA A. 18 COP(5°F) W/W 2.15 MOCP-Fuse Rating A. 25 Energy Star NO Type R410A Cooling System Tons 1.5 Model ATM150D23UFZ Cooling Rated Capacity Btu/h 18,000 Compressor Oil Type ESTER OIL VG74 Cooling Cap.Range Min-Max Btu/h 5,795-20,708 Oil Charge Fl.Oz. 17.64 Performance SEER 20.5 Rated Current RLA 10 Combination EER 12.15 Unit Width in(mm) 37.31(948) Dulled and Heating Rated Capacity (47°F) Btu/h 18,700 Unit Height in(mm) 27.64(702) Non-Ducted Heating Maximum Capacity (5°F) Btu/h 14,565 Unit Depth in(mm) 14.82(376) Heating Cap.Range Min-Max Btu/h 5,650-24,365 Outdoor Net Weight lbs(kg) 105.8(48) HSPF 22.5 Airflow CFM 1390 COP(47°F) WAN 3.7 Sound Pressure dB(A) 62.4 COP(5°F) W/W 2.125 Energy Star NO Cooling System Tons 1.5 Cooling Rated Capacity Btu/h 18,000 Cooling Cap.Range Min-Max Blu/h 5,780-19,476 SEER 18.5 Performance EER 11.8 Ducted Heating Rated Capacity (47°F) Btu/h 18,500 Heating Maximum Capacity (5°F) Btu/h 14,730 Heating Cap.Range Min-Max Btu/h 5,539-24,249 HSPF 10 COP(47°F) W/W 3.8 COP(5°F) W/W 2.1 Rated Combinations Two Zones 9+9 9+12 12+12 Copyright 2019 CAC/BDP•Atlanta,GA30339 Edition Date:11/2019 Catalog Na 38MGR-18-04SB SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces.38MGR-18-03S8 Construction View Outdoor Model: 38MGRQ18B--3 • i = ==‘ • ''''r '£, 1; fit /i a qe$Z�(3}ti aa�Jbw n k". at P r d + x ti'� 1,1 k"�'3 . i9} �Ii }z 1� aS' ( h 4t' Si �wt^4 1 S 8 -L#6 IS aEt `;C ' • • • Tp :: A,t I i • I I. 1 iA. -R rV -.�a.J.' r u \ ' /7! 11 s „ uu . C(fT1111)US "r...211 :'4.4.iii: Copyright 2019 CAC/BDP•Atlanta,GA30339 Edition Date:11/2019 Catalog No:38MGR-18-04SB SUBJECT TO CHANGE WITHOUT NOTICE Page 3 Replaces:38MGR-I8-03SB TAB 2 gocog and Aft Conditioning • High Wall Heat Pump Ductless System Indoor Model: 40MAQB09B--3tom to the lexperts' • Submittal Data Job Data: Location: Buyer: Buyer P.O.#: Carrier#: Unit Number: Model Number: Performance Data Certified By: Date: STANDARD FEATURES •Modes: Cool, Heat, Dry, Fan,Auto •Turbo Mode • Four fan speeds •Sleep Mode • Up-Down Louver control(fixed or swing) •Follow Me(senses temperature at handheld remote) •Heating Setback(46°F Heating Mode) •Quiet indoor operation •Aluminum Golden Hydrophilic pre-coated fins CONTROLS: •Wireless Remote Controller included with indoor unit •Wired Remote Controller KSACNO401AAA(7 Day programmable)(Optional) LIMITED WARRANTY* I? rf ort n )r ice • 10 year limited to original purchaser on compressor and parts fl upon timely registration,otherwise 5 years *For residential applications. See warranty for full details. System Size 9 Face Area I Sq.Ft. 2.19 Indoor Model 40MAQB09B--3 No.Rows 2 Voltage,Phase, Indoor Coil g Cycle I V/Ph/Hz 208/230-1-60 Fins per inch 20 Electrical Power Supply Indoor unit powered by outdoor unit Circuits 3 MCA I A. 0.2 Unit Width in(mm) 32.87(835) Controls Wireless Remote Controller(°F/°C Convertible) Standard Unit Height in(mm) 11.02(280) Wired Remote Controller(°F/°C Convertible) Optional Unit Depth in(mm) 7.80(198) Operating Cooling Indoor DB Min-Max °F(°C) 63-86(17-30) Net Weight lbs(kg) 19.18(8.7) Range Heating Indoor DB Min-Max °F(°C) 32-86(0-30) Number of Fan Speeds 4 Pipe Connection Size-Liquid in(mm) 1/4(6.35) Indoor Airflow(lowest to CFM 210/290/360/380 Piping highest) Pipe Connection Size-Suction in(mm) 3/8(9.52) Sound Pressure(lowest dB(A) 27/34/42 to highest) Air throw Data ft(m) 23(7) Moisture removal 'int/h(Ur 1.1 (0.5) Field Drain Pipe Size 01 in(mm) 0.625(16) Performance may vary based on the outdoor unit matched to.See compatible outdoor units pages for Performance Data. For Compatibility See Product Data Copyright 2018 Carrier Corporation•7310 W.Moms SI. Indianapolis,IN 46231 Edition Date:03/2018 Catalog No:SUB40MA0-09-3-02 SUBJECT TO CHANGE WTHOUT NOTICE Page 1 Replaces:SUB40MAO.09-3-01 Accessories 53DS-900---118 Condensate Pump(2081230V) KSACNO101AAA Wired Remote Control with Timer Function KSACNO401AAA Wired Remote Control 7 day Programmable* KSAIF0301AAA Wi-Firm Kit High Wall Mid-Tier KSAIC0101230 24V Interface Kit 230V 53DS-900--089 Insulated 25'Line Set-1/4"x 3/8" 53DS-900--090 Wireless Remote Control Locking Mount Kit Note:*KSACNO401AAA Wired Remote Control 7 Day programmable compatible with High Walls Units starting with Serial Number 0216V10001. **24V Interface compatible with High Walls Units starting with Serial Number 4316V10001. Construction View Indoor Model: 40MAQB09B--3 "r . . ,, -.-._ " z. i }1. H - Unit Width in(mm) 32.87(835) Unit Height in(mm) 11.02(280) Unit Depth in(mm) 7.80(198) Net Weight lbs(kg) 19.18(8.7) Om .1.„,,.... „, .,_ .„„„ Copyright 2018 Cartier Corporation•7310 W.Moms St. Indianapolis,IN 46231 Edition Date:03/2018 Catalog No:SUB40MAQ-093-02 SUBJECT TO CHANGE WITHOUT NOTICE Page 2 Replaces:SUB40MAQ-09-3-01 TAB 3 gocoks 3'4‘- w ` , 6 , , 2 C : « , . ( a 7 . . \ - : > � : , »< m, . < x » : . � dt . . - c ±< wz « . mm _ « A`y<» 2:44 1. # a \ ..ctA . . . . .;.. ..2- .m2 I :\ 4' \\ \\ / } / ,It * . \ ( < d.00 d»:, © y « t. «. . -.„.*— . \ \\ /\)d %»%2\?\d English Instruction manual Gobi II Contents djF. th Please read all safety and installation instructions completely before commencing. Introduction 02 . For indoor use only. General information 02 1 -÷ The identify electrical equipment designed primarily for indoor use Important safety notice 02 Waste of Electrical and Electronic Equipment Technical data 03 Ma (WEEE) Do not throw the pump in domestic waste Product description 04 e eCE compliant Transport and storage 06 To Certification mark that indicates conformity with health, safety and environmental protection standart for products Commissioning 06 ETL recognized component Maintenance 12 This product has been tested and meets the applicable Return and disposal 13 published standart for North America and Canada Troubleshooting 14 ROM RoHS compliant Replacement parts 15 Regulatory Compliance Mark(RCM) Compliant with the electrical safety requirements of Australia and New Zealand Introduction Thank you for purchasing our all new Gobi II condensate pump. Safety instructions The Gobi II has been completely redesigned retaining all the good features you like and upgrading everything else. Its digital water /\[ � r� Please read all safety and installation instructions sensor, universal voltage and user configurable flow ensure it is completely before commencing, the strongest, quietest under A/C mounted condensate pump on To prevent any risk only certified and appropria- the market today. tely trained staff with sufficient technical training and tools shall • install this product.Product installation and electrical connections both require professional training for safe installation and correct General information product operation. REFCO products have been specially designed and manufactured Save these instructions for further reference. for use by trained refrigeration and air-conditioning service en- yq gineers only. REFCO explicitly states that their products must only For indoor use only.To identify electrical equipment be sold to professionally trained service engineers. designed primarly for indoor use. Not submersible. These operating instructions contain important information about The Gobi II condensate pump is to be installed in accordance with handling the Gobi II.Safe operation of the device requires adheren- local and regional electrical codes. ce to all safety instructions and operating guidelines. WARNING:Disconnect all electrical power before starting - The local safety regulations applicable to the area in which the installation,maintenance,or service work. Gobi Il is being used should also be adhered to,along with gene- ral safety guidelines. A WARNING: Disconnect electrical power before removing and checking internal fuse. - The operating instructions are part of the product and should CAUTION: Do not install the REFCO condensate pump if be stored in close proximity to the Gobi II where they should be there are any signs of damage. readily accessible to qualified personnel at all times. - The qualified personnel must have carefully read and under- WARNING:Check the cables REFCO condensate pump stood the operating instructions prior to operating the device. f 1 power and alarm cords prior to,during and periodically for signs of damage. If either the power or alarm cords - The manufacturer shall not be liable for any damage whatsoever are damaged, isolate and disconnect the condensate arising through improper use,failure to comply with these ope- pump from service.Contact REFCO for a replacement. rating instructions,assignment of inadequately qualified person- The Gobi II combined power/alarm cable lead-out is nel,or unauthorised modification of the Gobi II. non-replaceable.If this is damaged the entire pump must - The general terms and conditions as set out in the sales docu- be replaced. mentation shall apply. WARNING:The REFCO condensate pump cables should not be cut,and should be routed so that they cannot be Symbols and writing standards damaged during and after installation. Aff CAUTION:All tubing connections are to be secured in place on WARNING/CAUTION the barb connections using self-locking cable tie-wraps. A An appropriate safety instruction should be followed or caution to a potential hazard exists. DO NOT use tools to connect the tubing. DOUS VOLTAGE DO NOT operate this product in ambient temperatures below 5 To ANGERindicate hazards arising from dangerous voltages. °C(41 °F). 2 Instruction manual Gobi II English DO NOT operate with incoming water above a temperature of 40 installed or leaking condensate pump,it is strongly recommended °C(104°F). that the alarm relay shall be used in fail-safe mode to completely shut down the air conditioning unit,should a pump failure occur. CAUTION: Do not allow any chemicals to come in contact with this condensate pump. Please remove the pump and water sensor before using any coil cleaning solutions and other chemicals. Flush jetSupply cord with connector a Ito,has only IPXO and the evaporator coils with water before reinstalling the condensate must be mounted in a dry area. pump and water sensor. Ensure the coils are chemical free before reinstallation. CAUTION: In all installations where any property damage and or personal injury may result from an inoperative,failed,incorrectly Technical data Maximum flow rate: 42 I/Hr.(11 GPH) Maximum suction: 3 m(9.80 ft.)self priming Maximum head: 20 m(65.60 ft.) Maximum horizontal run: 100 m(330 R.)at 0 head and 0 suction Sound: 19dBA at 1 m DIN EN ISO 3741:2011/DIN EN ISO 3744:2010 Voltage: 100—240 VAC 50/60 Hz auto sensing universal power input Power. 8 watts during maximum operation at 110v Alarm relay. 10 Amps NO or NC contacts with integrated replaceable 10A fuse 5 x 20 mm Weight: 1'100 g(2.45 Lbs.) • Discharge star tube: 6.25 mm I.D.(1/4")x 1 m(3.3 ft.) Packaging dimensions: 250 x 340 x 54 mm(9.9 x 13.4 x 2.1 inches) Bulk pack dimensions: 10 Pcs dimensions are 590 x 265 x 365 mm(23.2 x 10.4 x 14.4 inches) Color: RAL#9003 white Protection: Class II double insulation,fully potted,IP-44 Operation temp: Ambient 3°C to 40°C(37.5°F to 104°F)/Water 5°C to 25°C(41°F to 77°F) Compliance: Conforms to UL:778 and certified to CSA C22.2#68 ',",' Dili illl „,,,, r- i Capacity US G/Hr 12 14 O. •' .. N p 2 1 6 8 0 -a 16 i8 20 22 24 25 26 34 Capacity I/Hr ■ Gobi II 3 • English Instruction manual Gobi II Product description Pump body Factory-installed fuse Replaceable filter Digital sensor 13 Water tray Dip-switches USB port a Diagnostic LED Wall back plate chi Cover , i 4 arr;ht � o "s Dimensions pump = , i I 3 <.._...- 53.nm _. 285mm Provided accessories � , � ( �' hiR 'Pot Screws, 3 pcs. Star tube and Stop-Siphon device Alarm relay HR 10A fuse/ Screw anchors, 3 pcs Part No. 3004050 Cable ties, 3 pcs. Power cable Alarm cable Wire nut, indoor use only 4 Instruction manual Gobi II English LED alarm relay indications�� ,4i1i�`' 011ii��" Ills I0a4`1"'��iiilii�l"�l viU 1ill�it;�� 4r - Ii -, I ,i1111 E— ,Imi dl it , II-III __ I. 11 3 : `, E F� ate.., ; I {, , c � t ftI1 LED alarm relay operation table I Start up sequence NC No (normally closed) (normally open) Pump status Condensate level Default operation Fail-safe operation NO NO Not powered N/A o cam a COM NC NC NO NO�(� Powered Below alarm level COM '�QGOM NcO Nc° NO r., NO Powered Alarm-activated COM -0C0M NC° Nc O * Alarm relay operation is user configurable see page 9 LED indications in operation No power Pump is miswired or no incoming voltage Problem with NC system or alarm is miswired. Start up LED sequence Alternating red/green flashes 5x only then stops ,_ (default)NC and goes to standby mode. Start up LED sequence Alternating red/green flashes 5x only then stops (fail safe)NO and goes to standby mode. Standby mode- waiting for water Blinking green continuously. Pumping water 'i . Solid green. Running in low,med low, med high,or high power config. normal operation. High water level mode Blinking red. Running above high water level. • Alarm mode- �,�;; „ ,-� ,,,;, Solid red. Pump cannot keep up with water input. relay activated To prevent water overflow break power to A/C until water level reduces. Reconfigure code 11 Pump has had 3 u dip-switches for moreextra capacity.long rncycles,reconfigure 5 , . English Instruction manual Gobi II F. <::'.------> ---..",---- f-j ,--,="--- '..---;--' .„,„., , ON p-,-.1 ::'''''' ;%;1"- ; ,',;''-'; ;;; ..- i•iwo 0,,,_;;;' \ %t;;' ; ; ,"`f-'7 .;;;;''';;;;--------;--;; •`/'.k.-- --k,r.:.;.; Factory default ON ON ON ON 51 :1 1 2 1 2 1 2 1 2 a Ratings for air conditioning units low medium low medium high high The rating of the condensate pump has to up to 18K Btu/h up to 42K Btu/h up to 72K Btu/h up to 120K Btu/h be adjusted according to the power of the (5.3kW) (12kW) (21.1kW) (35kW) conditioning unit. Transport and storage Transport Inspect the GOBI II for any potential transportation damage.Any obvious damage should be reported to the vendor immediately. Storage -Storage temperature:-20 °C to+60 'C -Humidity: 0 to 90%relative humidity(no condensation) Commissioning ‘"IP-1111Cai°n e- -- - - - - ,-_----- 1- ir !I I ',I t __ ._______________. - ----J.. ..... .._.-..::.--- . The Gobi II pump can be mounted on the right or left side of an evaporator unit. Tools need - 11' '"1" -- 7.'-.7:7-----H1 --11-. 1107:: ' - - `d, ----- it i r---7,i7:-.-'-`:::------------- , '71aS----- ,11,1)k, 1 I • \ / „....-",.. --I,m / / „ .11 '"\,,\•1. t A A,%. I ' ) ( 1 1 1 ,, ,,r, , ... , :',.,:4 1, ..,... ,I ...-, 7/32" ]: ! _ — I I PH#2 6 Instruction manual Gobi II English s, fill roil itioCAUTION: Cables and pipes may be in the wall cavity. " Be careful)while drilling anchor holes. I 5.5mm/7/32" + :TTTz Dc pl' �\) cy / _ %e'7/ L `i, !� x 3 i E PH#2 x3 0 7 English Instruction manual Gobi II — Field supplied 1I f ,,;; �to drain t lb do x i WARNING: Disconnect all electrical power before starting INPUT POWER: installation, maintenance, or service work. 100-24OV, 50/60Hz, 2.5A(Max) The alarm relay fuse must be rated for the specific Installations only made by qualified people. application and of the HR type, 5 x 20mm 250 VAC, 10A(Max) T a , Plug connections have to be completely dry. hasSupply only IPXOcord andwithconnector must be mounted in a dry area. 1 i > EE , __ A iffi Y.+a. ._. C_...M.—_t ---- - 1 8 Instruction manual Gobi II English Below are examples of how REFCO pumps can be installed.For reference only. When indoor evaporator unit is powered from the outdoor condenser unit (drawing# ) 1 U 1 11 11 I l I II 11 I L Evaporator unit Condenser unit(outdoor) (indoor) Lo © � OData(communications)- i --- Earth(ground) O O Neutral live 2 © `•: O 100-240vac live 1 43 , I y ,._Connection u -' ( ) :made inside Utility power `""" the indoor z evaporator te :8w 3 Alarm relay operation table Or _o _+_ _0 __m _m Power up LED flash sequence m m m m m FIRM m m 0 No ©a 0 0 NC default NO fail-safe Pump status Condensate level operation operation N � i NOO NO No -i t)npowered n/a .75___OcOM 15_,-OcoM -' Pump or(pump fafere) tic NC I I • co for indoor COI0 NO Nam relay tic use only Powered Below alarm level _-Q�oM �roM NC Nc0 **ORANGE:Isolate with wire nut or tape during NC(normally closed)default operation NO NOO Powered Alarm activated O mM �cou NC NC When multi-split system is installed (drawing To change alarm relay operation #'` 1.Unplug pump r^d c'" 2.Move dip-switch positions to •• NC= Normally closed relay 1 >'- 3.Plug pump in NO=Normally open relay 4.Wait for one green LED blink a • To use fail-safe operation. 5.Move dip-switch positions to a a 1.Remove the violet wire from indoor connection and isolate with wire nut. +^=' 6.Wait for one red LED blink 0 2.Connect the orange wire to the sa me 1 II I I 1 I l a indoor connection. I II I 1 7.Reset dip-switch positions to •• 3.Change alarm relay to fail-safe operation Evaporator units(indoor) I • aarm , 8.Wail for one green LED blink 0 aaety • 0 0 0 © i 9.Unplug pump I uk dI ___ _ _ i 10.Set the dip-switches back to the desired capacity configuration.(Low,medium-low,medlum-high,high) I 11.Plug pump in and check that power up LED sequence matches the desired alarm relay operation 12.0one! r I 0 ,t„ Ely', I ,1/4. N To reset alarm relay to default(NC)operation repeat steps 1 thru 11 J JO p .5 _ t I I VRF/VRV condenser unit(outdoor) ® no I l e 0 "o 1 Data 1 1 © P,0411117 . : _ i ---- A 1 °to" Earth .round ® Alarm relay © 1 BLUE Pump ` Neutral live 2 © �.* N for indoor 1 BROWN 100-240vac (live 1) use only Oi © C ® I Utility power *1 ORANGE:Isolate with wire nut or tope during NC(nrma ly closed)default operation 9 English Instruction manual Gobi II Below are examples of how REFCO pumps can be installed.for reference only. When outdoor condenser is powered from the indoor evaporator unit (drawing#3) r 1 Evaporator(Indoor) 1` i II II I I I II II I t- -I Condenser unit(outdoor) ® i Data(communications) i I \J O CO ® O )—•—•—•—•—•—•—•—•— I 3 L, Earth (ground) 0 Utility power Neutral live 2 Or* 100-240vac (live 1) O 411. Connection made inside the indoor i evaporator L' gti w• Alarm relay operation table Or e3' ' a: m > m' * _ /.D( Power up LED flash sequence ®M I ®i ® i m®m 00 O "° ® NC default NO fail-safe Pump status Condensate level e operation operation NOO no NO - (JnpOWered n/a `Jel^ I l cOM �coM or(pump failure) I • Pump NC NC i •NC cost for indoor No no Moan Relay use only Powered Below alarm level �coM NC° COM NC **ORANGE:Isolate with wire nut or tape during NC(normally closed)default operation NO NO0 Powered Alarm activated �Jcos 75„ COM NCO NC To change alarm relay operation 1.Unplug pump 2.Move dip-switch positions to .II NC= Normally dosed relay 3.Plug pump In NO=Normally open relay Power only with no alarm circuit 4-Wait for one green LED blink Q (drawing#4) To use fail-safe operation. 5.Move dip-switch positions to in• 1.Remove the violet wire from indoor connection and isolate with wire nut. 6.Wait for one red LED blink 0 2.Connect the orange wire to the same indoor connection. Not recommended:Water damage can occur if 7.Reset dlp-switch positions to •• 3.Change alarm relay to fail-safe operation drain line becomes kinked,pinched or plugged. Water damage can occur if pump fails. &WOit for one green LED blink 9.Unplug pump 10.5et the dip-switches back to the desired capacity configuration.(Low,medium-low,medium-high,high) 11.PIug pump In and check that power up LED sequence matches the desired alarm relay operation 12.Done! Pump(for indoor use only) \ * To reset alarm relay to default(NC)operation repeat steps 1 thru 11 %Q O Alarm cable not used Condenser unit(outdoor) ... O Data line O O Earth (ground) O ,:* Neutral (live 2) 2 w �• • 100-240vac(live 1) O CI- - Evaporator unit(indoor) L 10 • Instruction manual Gobi II _ English Supply cord with connector e , has only IPXO and must be mounted in a dry area. ' 1 l 'f ' S e. it- s, le 11(t �lr � �J ''' -7--I:-1-7:I.:I.....' - - - 11 English Instruction manual Gobi II iti II11 __ —_ - -rr 1 i, 1 , .r tt; M �- f. r i 1 Pt 'M 1 , 1 , 1 v \ \_-__,lam-` ,{l i i 7 4 - -XE------r- __ i rri i r- i Maintenance Water filter maintenance Regular cleaning/replacement of the Gobi II water filter will help to prolong the life of the pump.The sole purpose of the water filter is to prevent foreign debris from entering the pump itself.The time period between filter service can only be determined from the specific environment in which the pump is installed.We recommend cleaning or replacing the water filter a minimum of every 12 months. However,when installed in environments with high dust,smoke,cooking oils or the possibility of algae growth it is recommended to clean or replace the filter every 3 months. To clean/replace the water filter,simply remove it from the Gobi II suction barb and thoroughly wash with cold water and replace on the pump suction barb. 12 Instruction manual Gobi II English • Change filter <111i1( ' 1,j i$-(i iIII % it � r ;` 'ii °t., ;� x C ' p I ( ,1 -- b< l �111 � � tl ,.,.j NY Change alarm fuse : s-;< 11l i ' ii ' , l l u / 47/ f/ tj 1 WARNING: jak Disconnect all electrical power before starting installation, maintenance,or service work. The alarm relay fuse must be rated for the specific applica- tion and of the HR type, 5 x 20 mm 250VAC, 10A(MAX) iik Installations only made by qualified people. . Return and disposa. At the end of useful life of the condensate pump send the product to the separate collection for electric and electronic devices. (According to local regulations) 13 English Instruction manual Gobi II 0 0 - I I Fault Correction No LED lights Check for incoming voltage.The blue and brown wires are for power. • Pump runs constantly Check filter placement.The water filter should not touch the digital sensor. Check the digital sensor for dirt,mold or debris.Clean with water. Check all tubing connections and ensure they are firmly pressed on the connection barbs and secured using cable ties.Check the entire drain line for clogs,kinks or the tube being pinched. If the pump is running constantly and water is flowing from the end of the drain line then you need to change the dip-switch power settings to increase the pump's capacity.The system has too much water or lift for the pump's current power setting. A/C unit is off Check the pump LED status light. If it's solid red(not blinking)AND the alarm wiring is connected pro- perly,then the pump alarm relay is intentionally stopping the NC unit from running.This prevents water overflow and possible water damage.This is the correct function of a condensate pump alarm relay. If the alarm wiring has been used,check the HRC alarm fuse for continuity using a multimeter and replace it if necessary.Glass fuses can be inspected visually. If the alarm wiring has been used,check that the color of wires used matches the alarm mode(default vs fail-safe)you have selected:grey+violet for default(N/C)alarm mode or grey+orange for fail-safe (N/O)alarm mode. If the alarm wiring has been used and the wiring is correct,check the status LED; if it is OFF,with no LED lights at all,then there is a fault either with the power main supply to the pump or with the pump itself. During alarm status the pump itself will continue to run to decrease the water level even when the NC unit is not running.Once the water level is low enough,the pump will automatically reset the alarm relay to re-connect power back to the A/C unit. Please note: Many outdoor NC units have a 5 min.time delay before they turn on the compressor and resume normal cooling operation. Alarm is activated If the alarm is activated(LED is solid red),the pump has too much incoming water for it to keep up. Once the water level gets too high on the digital sensor it will trip the alarm relay and stop power to the A/C system.(Only if the alarm wiring is used).The drain line could be blocked,kinked or pinched.You may have incorrect capacity settings on the pump relative to the capacity of the NC unit and or a high lift vertical run. Water is dripping Check to ensure the alarm cable is correctly installed according to the appropriate wiring diagrams. Please note:There are different diagrams according to different types of NC systems. If the alarm is not used and the drain line gets blocked, kinked or clogged,the pump can overflow.This is why you should always use the alarm function. Check all your hose connections. If you have a high head pressure(long vertical run),the water pressure can blow a hose off its barb.This is why you should always use the factory supplied cable ties. With Gobi II pump:Ensure the wall back plate,the water tray and the Gobi II pump body are all mounted and installed level. Pump is noisy Check the filter placement.If the water filter is touching the digital sensor,the digital sensor may believe it is water and activate the pump causing it to run dry when it should not be running at all. Clean the digital sensor and the filter with water. Configure pump capacity correctly according to the A/C capacity and lift rise and run of the drain line. (See dip-switch settings in installation instructions). Slurping or gurgling Check for and correct a siphon in the drain line.(Review siphon specific instruction sheet). If the drain line extends below the level of the pump,when the pump shuts down,the weight of the water remaining in the drain line will create a siphon effect which will suck water away from the pump causing the pump to start and run dry until reprimed with water.This can cause slurping and gurgling noises.Correctly install your drain line to prevent a siphon from occurring. LED lights flash Immediately on initial power-up the pumps will always have a LED start sequence 5x and then go into standby(blinking green).This is normal operation.This LED start sequence is the only indication of which way the alarm relay is currently configured.NO(Normally Open)or configured in NC(Normally Closed).The alarm relay is user configurable and can be changed back and forth.(See wiring diagram instructions). 3 red & 3 green This is the pump reconfigure code.The pump is asking for help! If it has had 3 consecutive long run LED flashes cycles where it went from standby mode all the way into alarm mode,it is asking to be re-configured for more power as its current dip-switch power settings are too low for the incoming water flow,lift or both. Give it more power by reconfiguring the dip-switch settings.This reconfigure code will only appear after 3 consecutive long run cycles that went into alarm mode. 14 Instruction manual Gobi II English Re.Iacement .arts and accessories HSG-4065/4 '' FIL-4064/4 Stop-Siphon Device, 4 pcs. Filter, 4 pcs. Part No 3004065 Part No 3004064 w FUS-4050/10 KIT-4087 Fuses 5x20 10A, 10 pcs. Star tube with Stop-Siphon device Part No 3004050 Part No 3004087 PVC TUBE _ Plastic tube 6 mm (1/4"), minimum 30 meters Part No 4679160 15 qiiN . \. % 2 ƒ w \ /» //. . Illiammo 2 ploiliviimmikril SI } j \ 11 ƒ 4 die 114 \ " d2y:\\ : . . . ; : m« : . . m - = z . � � : , , gtiiiiiiiiiiiill i::-!Iiiii.,11L''''4'414!Ill'kiiiiitilli:121111: dy> R m&cuw� d imaIllitileign < . : d u�e g 2 \ \ » \'\ @SH6G� - Switzerland minigiggeulia \ \11,48014941101, \ A�n +G 4191972 82 ^ A * +q a #§ » y . - ° 5 p . i : . in @ c ch 2 = ^ _«r m>h % TAB 4 gocoas Marker Products Company HotPod Duct Mounted Heating Standard Features • B"and 6"sizes available hot podiT • Use to heat cold rooms or additions without upgrading central system • Fan only operation for increased CFM output for NC cycles • 6"1000/500 Watt • 8"1440/720 Watt • Two stage operation • 120v corded and hard wire models available • 10'Cord length on corded models • Zero clearance for all models • All models include UT8003 low voltage thermostat • Optional wireless thermostat • Silent booster option available for rigid duct applications • Silent boot can only be uses with rigid ductwork 4 7 PuceW Standard HotPod Models ITEM# MODEL DESCRIPTION CFM WATTS VOLTS MCA LBS NOM DIMENSIONS 290074 HP6-1000120-2T 6"0 INLET-HARDWIRE 130 1000/500 120v 8.33 4.0 11"X 9"X 6" 290043 HP6-1000120-2CT 6"0 INLET-WITH CORD 130 1000/500 120v 8.33 4.0 11"X 9"X 6" 290081 HP8-1440120-2T 8"0 INLET-HARDWIRE 210 1440/720 120v 12.6 6.0 11"X 10"X 8" 290067 HP8-1440120-2CT 8"0 INLET-WITH CORD 210 1440/720 120v 12.6 6.0 11"X 10"X 8" Additional Features Premium Components • Air flow through design • Integrated furnace control board • Quiet operation • Conformal anti-corrosion coating • 1 year limited warranty • Heavy duty high cycle relays • 50,000 hour operation rating • 24 Volt 10VA transformer • Easy to install with no complicated • Low voltage fused protection ductwork or wiring • Self contained premium blower • Economical alternative to conventional • High efficient motor zoning.Saves money,lowers heating bills • High temperature ball bearings and is easy to Install.Save on energy • High temperature thermal plastic fan blades costs by keeping one room warmer or • Premium safety discharge air limit cooler than the rest of the house with the • 100,000 cycle rating ` ,s 20 • 25 30° energy efficient HotPod! • Blocked airflow safety limit SC • e0 • 70 • so • High gloss powder coat paint finish • 24 Gauge galvanized spiral steel body SF-1 • Cast aluminum internal construction UT8003 Wall Mounted Thermostat Jacobs Heating ® 4474 SE Milwaukie Ave - Portland, OR 97202 o JacobsHVAC.com TAB 5 oecom BRêANSPECIFICATION SHEET MODELS A80, A110 ' ` " vir FLEXTM SERIES FANS DESCRIPTION TYPICAL SPECIFICATION BLOWER: Fan shall be Broan Model A80(A110). • Plug-in,permanently lubricated motor-engineered for Fan shall have corrosion resistant galvanized steel housing continuous operation with four-point mounting capability.It shall be ducted to a • Dynamically balanced centrifugal blower wheel for quiet, roof or wall cap using 4"round ductwork. efficient performance • Low RPM for quiet operation Blower assembly shall be removable,have a centrifugal- type blower wheel and a permanently lubricated motor HOUSING: designed for continuous operation. • Rugged,26 gauge,galvanized steel construction Non-metallic damper/duct connector shall be included. • Polymeric,4"duct connector with tapered sleeve and no Air delivery shall be no less than the airflow values and metallic clatter no greater than the sound level values listed in the HVI • 534"height allows for 2"x 6"ceiling installations Performance Specifications provided in this specification • Sturdy,easy,four-point mounting directly to joist (see following chart).All air and sound ratings shall be • Can be mounted in ceilings up to 7/12 pitch certified by HVI. • Can be installed in a wall if mounted 8-ft.or more above Ceiling Ventilator shall be U.L.Listed for use over bathtubs the floor and showers when connected to a GFCI protected branch GRILLE: circuit. • Polymeric construction • Innovative design-the result of extensive research with designers and consumers CONTROLS(Purchase separately): 2100 II • Refer to Broan's catalog for a complete line of C uI us li V I accessories to effectively adapt these fans to your CERTIFIED construction requirements. U.L.Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit(ceiling mount only). 1-Year Warranty Broan Hartford,Wisconsin www.broan.com 800-558-1711 Venmar Ventilation ULC Drummondville(Quebec),Canada www.broan.ca 877-896-1119 REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date 91D 99045370D PERFORMANCE RATINGS -- FLEXTM SERIES FANS HVI PERFORMANCE ELECTRICAL & WEIGHT 0.1 Ps-Static Pressure(In.H2O) 0.25 Ps Model Volts Hz Amps Shipping Model Airflow Sound Power Efficacy Airflow Weight (CFM) (Sones) (Watts) (CFM/W) (CFM) A80 120 60 0.37 10.0 lb. A80 80 2.0 43.1 1.89 67 A110 120 60 0.40 10.0 lb. A110 110 3.0 473 2.36 102 ® HVI-2100 CERTIFIED RATINGS comply with new 21 00 •� testing technologies and procedures prescribed by the H V HomeVentilating Institute,foroft-the-shelf products,as they are available to consumers.Product performance is rated at 0.1 in. static pressure, based on tests CERTIFIED conducted in a state-of-the-art test laboratory.Sones AIR FLOW PERFORMANCE area measure of humanly-perceived loudness,based on laboratory measurements. Model A80 0.6 0.5 c US - c t7 � ; 0.4 j R y3 a y 0.3 c 4. Al y- 0.2 l x" . i l 0.1 \ )111 -' e la� 0.0 ijrp1�-�? �a 0 10 20 30 40 50 60 70 80 90 100 1IIII1�� S Air Flow(CFM-Cubic Feet per Minute) II0f,�_Rf117 3 r � t,9, Model A110 \ / O a7 y \�\ 11111111111111111111111111oInu11nn111111111111111nu111111111 11111111OhI111111IIII11111111II11111111IulIIIIIIl1I1111111I11II IIIIIIIIIIIIIIIIIIIIllI III 111uu111111I111111111111IlIlIIIluuuu. \\\��\\�� 0.6 1112 lll1111ll ullllllllll11uuuIIull11111lllllIIIIlllllll11111 uu1:.11 munn1111lImIllII1u1I11lnnmlll III llllll uull �.,-: d mull.: s' 0.5 111111111111i:u11111111111111111111111111111111111111111I11111111I ::- //`, �cL mnmumnnw.::.Innullnnunumm�nnnnunw ? :9I1IuI111111Iuu11111ulu11O11uiuii \ / d 123 mnmmnmm�onun.:9nnnnnnnnnumm�nnw �G` D.4 Ilmmnnllumnmm111101nunnununmml 111111111 NOTE:Dimensions shown are in inches- a m IIIII11111111111111IIIIII1111llIIIIIIIIIIIC!1111IIIII111111111111 '_'. w 0.3 IIIIIIIIII111111111111111111II1111111llllll112 m 2111111I11I11III Zia)— 11111111IIIIIIII1111111111111111111111111111111111►1IIIIIIIIlhlII CL 0.2 I r: himllIIIl1I 111111111IIII111111Il1IIIIIl llll 1111111111111111111 ll 0 ll llll11II I 0.1 1111111llllllIIIII11111111111111111111111111111111111110 11111111111111111I111111111111111111111111I1111111111111k11111111 0.0 11111111111111111111I111111111111111111111111111111111111111:111I 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Air Flow(CFM-Cubic Feet per Minute) BR „�N® Broan Hartford,Wisconsin www.broan.com 800-558-1711 r Venmar Ventilation ULC Drummondville(Quebec),Canada www.broan.ca 877-896-1119