Report MECZOZ0 -C.OZl3 739 SW 2,440 RECEIVED COMcheck Software Version 4.1.1.0 APR 0 9 2020 Mechanical Compliance Certificate CITY OFTIGARD BUILDING DIVISION Project Information Energy Code: 90.1 (2016)Standard Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Location: Portland, Oregon Climate Zone: 4c Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 11740 SW 72nd Ave. Jacobs Heating Mark Denyer Tigard, OR 97223 (503) 234-7331 MFIA CONSULTING ENGINEERS 2007 ASH ST. PORTLAND, OR 97214 503 234 0548 Mechanical Systems List Quantity System Type&Description 1 HP-3(Single Zone): Split System Heat Pump Heating Mode:Capacity= 18 kBtu/h, Proposed Efficiency= 10.30 HSPF, Required Efficiency=8.20 HSPF Cooling Mode:Capacity= 18 kBtu/h, , No Economizer, Economizer exception:Low Capacity Residential Proposed Efficiency=22.50 SEER, Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 1 I FC-1 --Compliance(Motor nameplate HP method): Passes Fans: FAN 1 Supply,Constant Volume,870 CFM,0.3 motor nameplate hp,0.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 90.1 (2016) Standard requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist Mark Denyer yZ� 4-8-2 0 Name-Title Signature Date Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\Jacobs Heating &Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 1 of 10 Salon T.I.cck COMcheck Software Version 4.1.1.0 Inspection Checklist Energy Code; 90.1 (2016) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review Complies? Comments/Assumptions & Req.ID 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 6,4.4.2.1, calculations provide all information ODoes Not 6.7.2 with which compliance can be ❑Not Observable Location on plans/spec: M6.0 [PR2]1 determined for the mechanical ❑Not Applicable systems and equipment and pp document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and handbooks. 4.2.2, Plans, specifications, and/or '❑Complies Requirement will be met. 8.4.1.1, calculations provide all information ❑Does Not 8.4.1.2, with which compliance can be 8.7 determined for the electrical systems ❑Not Observable [PR6]2 and equipment and document where I❑Not Applicable exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. • 6.7.2.4 .Detailed instructions for HVAC ❑Complies Exception: Requirement does not apply. [PR5]1 systems commissioning included on ❑Does Not the plans or specifications for projects Observable >=50,000 ft2. ❑Not Applicable Additional Comments/Assumptions: r1�High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\Jacobs Heating &Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 2 of 10 Salon T.I.cck Section Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID •- 6.4.3.7 Freeze protection and snow/ice ❑Complies Exception: Requirement does not apply. [FO9]3 melting system sensors for future ❑Does Not connection to controls. ❑Not Observable • ❑Not Applicable Additional Comments/Assumptions: n High Impact(Tier 1) r2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\jacobs Heating &Air Conditioning\10031 72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 3 of 10 Salon T.I.cck Section Mechanical Rough-In Plans Verified Field Verified # Inspection Value Value Complies? Comments/Assumptions & Req.ID -• 6.4.1.4, HVAC equipment efficiency Efficiency: Efficiency:_ :❑Complies See the Mechanical Systems list 6.4.1.5 verified. Non-NAECA HVAC ❑Does Not for values. [ME1]2 equipment labeled as meeting 90.1. ❑Not Observable ❑Not Applicable 6.4.3.4.1 Stair and elevator shaft vents ❑Complies Exception: Requirement [ME3]3 have motorized dampers that ❑Does Not does not apply. automatically close. ❑Not Observable ❑Not Applicable 6.4.3.4,2, Outdoor air and exhaust systems ❑Complies Requirement will be met. 6.4.3.4.3 have motorized dampers that ❑Does Not [ME4]3 automatically shut when not in use and meet maximum leakage ['Not Observable rates. Check gravity dampers ❑Not Applicable where allowed. 6.4.3.4.5 Enclosed parking garage ❑Complies Exception: Requirement [ME39]3 ventilation has automatic ❑Does Not does not apply. contaminant detection and capacity to stage or modulate ❑Not Observable fans to 50%or less of design ❑Not Applicable capacity. 6.4.3.4.4 Ventilation fans >0.75 hp have ❑Complies Requirement will be met. [ME5]3 automatic controls to shut off fan ❑Does Not when not required. ❑Not Observable ❑Not Applicable 6.4.3.8 Demand control ventilation ❑Complies Exception: Systems with a [ME6]' j provided for spaces >500 ft2 and ❑Does Not design outdoor airflow less ;>25 people/1000 ft2 occupant ❑Not Observable than 1200 cfm. density and served by systems with air side economizer, auto ❑Not Applicable modulating outside air damper control, or design airflow>3,000 cfm. ; 6.5.3.2.1 DX cooling systems >=75 kBtu/h ❑Complies Exception: Requirement [ME40]2 (>= 65 kBtu/h effective 1/2016) ❑Does Not does not apply. and chilled-water and ❑Not Observable evaporative cooling fan motor hp See the Mechanical Systems list >= V4 designed to vary supply ❑Not Applicable for values, fan airflow as a function of load and comply with operational requirements. 6.4.4.1.1 Insulation exposed to weather ❑Complies Requirement will be met. [ME7]3 protected from damage. ❑Does Not Insulation outside of the conditioned space and associated ['Not Observable with cooling systems is vapor ❑Not Applicable retardant. 6.4.4.1.2 HVAC ducts and plenums R-_ R-_ ❑Complies Exception: Ducts/plenums [ME8]2 insulated per Table 6.8.2.Where ❑Does Not 'located in heated, semi- ducts or plenums are installed in 'heated, or cooled spaces. or under a slab,verification may ! ❑Not Observable need to occur during Foundation ❑Not Applicable Inspection. 6.4.4.1.3 HVAC piping insulation thickness. in. in. ❑Complies Exception: Requirement [ME9]2 Where piping is installed in or ❑Does Not 'does not apply. under a slab, verification may need to occur during Foundation ❑Not Observable Inspection. ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\Jacobs Heating &Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 4 of 10 Salon T.I.cck Section Mechanical Rough-In Plans Verified Field Verified Inspection Value Value Complies? Comments/Assumptions & Req.ID 6.4.4.1.4 Thermally ineffective panel ❑Complies Exception: Requirement [ME41]3 surfaces of sensible heating ❑Does Not does not apply. panels have insulation >= R-3.5. [Not Observable • ❑Not Applicable 6.4.4.2.1 Ducts and plenums having ❑Complies Exception: Requirement [ME10]2 pressure class ratings are Seal ❑Does Not does not apply. Class A construction. ❑Not Observable ❑Not Applicable 6.4.4.2,2 :Ductwork operating >3 in. water ❑Complies Exception: Requirement [ME11]3 :column requires air leakage ❑Does Not does not apply. testing. ❑Not Observable ❑Not Applicable 6.5.2.3 :Dehumidification controls EComplies Requirement will be met. [ME19]3 provided to prevent reheating, ❑Does Not recooling, mixing of hot and cold airstreams or concurrent heating :Not Observable and cooling of the same ❑Not Applicable airstream. 6.5.2.4.1 Humidifiers with airstream ❑Complies Exception: Requirement [ME68)3 mounted preheating jackets have ❑Does Not does not apply. preheat auto-shutoff value set to .activate when humidification is ❑Not Observable not required. ❑Not Applicable 6.5.2.4.2 Humidification system dispersion ❑Complies Exception: Requirement [ME69]3 'tube hot surfaces in the EDoes Not does not apply. airstreams of ducts or air- handling units insulated >= R- ENot Observable 0.5. ❑Not Applicable 6.5.2.5 Preheat coils controlled to stop ❑Complies Requirement will be met. [ME70]3 heat output whenever ❑Does Not mechanical cooling, including ,Location on plans/spec: economizer operation, is active. ❑Not Observable NA ❑Not Applicable 6.5.2.6 !Units that provide ventilation air ❑Complies Exception: Requirement [ME106]3 to multiple zones and operate in ❑Does Not ,does not apply. conjunction with zone heating and cooling systems are ❑Not Observable 'prevented from using heating or ❑Not Applicable heat recovery to warm supply air above 60°F when representative building loads or outdoor air :temperature indicate that most 'zones demand cooling. 6.5.3.6 'Motors for fans >= 1/12 hp and ❑Complies Exception: Requirement [ME72)2 < 1 hp are electronically- ❑Does Not does not apply. commutated motors or have a minimum motor efficiency of ['Not Observable 70%.These motors are also ❑Not Applicable speed adjustable for either balancing or remote control. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\jacobs Heating &Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 5 of 10 Salon T.I.cck Section Mechanical Rough-In Plans Verified Field Verified Inspection Value Value Complies? Comments/Assumptions & Req.ID 6.5.3.4 Parallel-flow fan-powered VAV air ❑Complies Exception: Requirement [ME108]2 terminals have automatic ❑Does Not does not apply. controls to a)turn off the terminal fan except when space ENot Observable heating Is required or if required ❑Not Applicable for ventilation; b)turn on the terminal fan as the first stage of heating before the heating coil is :activated; and c) during heating for warmup or setback temperature control, either operate the terminal fan and heating coil without primary air or reverse the terminal damper logic and provide heating from the central air handler through primary air. 6.5.3.7 Required minimum outdoor air EComplies Requirement will be met. [ME109]2 rate is the larger of minimum ❑Does Not outdoor air rate or minimum Location on plans/spec: exhaust air rate required by ENot Observable M6.0 Standard 62.1, Standard 170, or ENot Applicable applicable codes or accreditation standards. Outdoor air ventilation systems shall comply with one of the following: a) design minimum system outdoor air provided < 135%of the required minimum outdoor air rate, b) dampers, ductwork, and controls allow the system to supply <= the required minimum outdoor air rate with a single set-point adjustment., or c) system includes exhaust air energy recovery complying with Section 6.5.6.1. 6.5.3.3 Multiple zone VAV systems with ❑Complies Exception: Requirement [ME42]3 DDC of individual zone boxes ❑Does Not does not apply. have static pressure setpoint reset controls. ['Not Observable See the Mechanical Systems list ENot Applicable for values. 6.5.4.2 ,HVAC pumping systems with >= ❑Complies Exception: Requirement [ME25]3 !3 control values designed for EDoes Not does not apply. variable fluid flow(see section details). ❑Not Observable ❑Not Applicable 6.5.6.1 Exhaust air energy recovery on ❑Complies Exception: Requirement [ME56]1 systems meeting Tables 6.5.6.1- ❑Does Not does not apply. 1, and 6.5.6.1-2. ❑Not Observable ❑Not Applicable 6.5.7.1 Conditioned supply air to space ❑Complies Requirement will be met. [ME100]2 with mechanical exhaust <=the ❑Does Not greater of criteria of supply flow, ❑Not Observable required ventilation rate, exhaust flow minu the available transffer ENot Applicable lair(see section details). 6,5.7,2.1 Kitchen hoods >5,000 cfm have ❑Complies :Exception: Requirement [ME32]2 make up air>=50%of exhaust ❑Does Not 'does not apply. air volume. ENot Observable ❑Not Applicable n High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\jacobs Heating &Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 6 of 10 Salon T.I.cck Section Mechanical Rough-In Plans Verified Field Verified # Inspection Value Value Complies? Comments/Assumptions & Req.ID ' 6.5.7.2.4 Approved field test used to ❑Complies Exception: Requirement [ME49]3 evaluate design air flow rates ❑Does Not does not apply. and demonstrate proper capture and containment of kitchen :Not Observable exhaust systems. ❑Not Applicable 6.5.8.1 Unenclosed spaces that are ❑Complies Exception: Requirement [ME3412 heated use only radiant heat. ❑Does Not does not apply. :Not Observable ❑Not Applicable 6.4.3.9 Heating for vestibules and air ❑Complies 'Exception: Requirement [ME6312 curtains with integral heating ❑Does Not does not apply. include automatic controls that ❑Not Observable shut off the heating system when outdoor air temperatures >45F. ❑Not Applicable Vestibule heating and cooling systems controlled by a thermostat in the vestibule with heating setpoint <= 60F and cooling setpoint>= 80F. 6.5.10 Doors separating conditioned ❑Complies Exception:Alteration [ME73]3 space from the outdoors have ❑Does Not ,project to existing building. controls that disable/reset ['Not Observable heating and cooling system when open. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact (Tier 3) Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\Jacobs Heating&Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms172nd Ave Apts Page 7 of 10 Salon T.I.cck Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID 8.4.2 At least 50%of all 125 volt 15-and ❑Complies Requirement will be met. [EL10]2 20-Amp receptacles are controlled by ❑Does Not an automatic control device. I❑Not Observable'. ❑Not Applicable 8.4.3 New buildings have electrical energy DComplies Requirement will be met. [EL11j2 use measurement devices installed. ❑Does Not Where tenant spaces exist, each 'tenant is monitored separately. In ❑Not Observable'. buildings with a digital control system ❑Not Applicable the energy use is transmitted to to control system and displayed graphically. 10.4.1 Electric motors meet requirements ❑Complies Requirement will be met. [EL9]2 where applicable. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\Jacobs Heating &Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 8 of 10 Salon T.I.cck Section # Final Inspection Complies? Comments/Assumptions & Req.ID 6.4.3.1.2 Thermostatic controls have a 5 °F ❑Complies Requirement will be met. [FI3)3 deadband. ❑Does Not ❑Not Observable ❑Not Applicable 6.4.3.2 Temperature controls have setpoint ❑Complies Requirement will be met. [F120)3 overlap restrictions. ❑Does Not ❑Not Observable; ❑Not Applicable 6.4.3.3.1 'HVAC systems equipped with at least ❑Complies Requirement will be met. [F121]3 ,one automatic shutdown control. DDoes Not ❑Not Observable ❑Not Applicable 6.4.3.3.2 Setback controls allow automatic ,❑Complies ,Requirement will be met. [F122]3 restart and temporary operation as EDoes Not required for maintenance. ❑Not Observable:. j❑Not Applicable 6.4.3.5 Heat pump controls prevent ❑Complies .Requirement will be met. [F15]3 supplemental electric resistance heat '❑Does Not from coming on when not needed. ❑Not Observable ❑Not Applicable 6.4.3.6 ;When humidification and ❑Complies Requirement will be met. [FI6)3 !dehumidification are provided to a ❑Does Not zone, simultaneous operation is prohibited. Humidity control prohibits ❑Not Observable the use of fossil fuel or electricity to ❑Not Applicable produce RH > 30%in the warmest zone humidified and RH < 60%in the coldest zone dehumidified. 6.7.2.1 Furnished HVAC as-built drawings ❑Complies Requirement will be met. [FI7]3 submitted within 90 days of system ,❑Does Not acceptance. ❑Not Observable ❑Not Applicable 6.7.2.2 Furnished O&M manuals for HVAC Complies Requirement will be met. [F18]3 systems within 90 days of system ❑Does Not acceptance. ❑Not Observable ❑Not Applicable 6.7.2.3 'An air and/or hydronic system ❑Complies Exception: Requirement does not apply. [F19]1 balancing report is provided for HVAC '❑Does Not systems serving zones >5,000 ft2 of conditioned area. ['Not Observable ❑Not Applicable 6.7.2.4 HVAC control systems have been ❑Complies :Requirement will be met. [F110]1 tested to ensure proper operation, ❑Does Not calibration and adjustment of controls. ENot Observable ❑Not Applicable 10.4.3 Elevators are designed with the ❑Complies Exception: Requirement does not apply. [F124? proper lighting,ventilation power, and ❑Does Not standby mode. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:\jacobs Heating &Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 9 of 10 Salon T.I.cck Project Title: 72ND AVENUE APARTMENTS-SUITE 130 T.I. Report date: 04/08/20 Data filename: G:1Jacobs Heating &Air Conditioning\10031_72nd Apts-Salon TI\Energy Forms\72nd Ave Apts Page 10 of 10 Salon T.I.cck