Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
. . RECEIVED . 4.... 0 AT&T MAR 3 0 202 _ CITY QV TIGARD AT&T SITE \IUMIBEP: PT87 BUSI\ESS UNIT #: 874135 p.UILDIN ; DlvlsiON a: CROWN AT&T SITE \AVE: TIGARD NE LIABILITY CASTLE SITE ADD E S S•. 10955 SW 65TH AVE 1505 WESTLAKE AVENUE NORTH,SUITE 800 AT&T FA CODE: 10094051 The City of Tigard and its TIGARD, OR 97223 SEATTLE,WA 98109 employees shall not be AT&T PACE NU V B E : MRWOR046691 responsible for discrepancies COUNTY: OFFICE COPY WASH ' \GTO\ 60 INA00." SITE TYPE: MONOPOLE Which may appear herein. JU ISDICTIO\ : CITY OF TIGAD Approved plans TWA/FAA APPROVED HGT: 100'-0" Not �eq'd P.MARSHALL&ASS • OCIATES shall be on job site. PROJECT: 5 G \ R 1 S SITE INFORMATION DRAWING INDEX LOCATION MAP PT87 CROWN CASTLE USA INC. TIGARD NE SHEET # SHEET DESCRIPTION BU yy: 874135 SITE NAME: T-1 TITLE SHEET & PROJECT INFORMATION tt SITE ADDRESS: 10955 SW 65TH AVE T_2 GENERAL NOTES TIGARD NE TIGARD, OR 97223 • ... COUNTY: WASHINGTON 10955 SW 65TH AVE C-1.1 OVERALL SITE PLAN WEST TIGARD, OR 97223 MAP/PARCEL#: 1S136AD06300 C-1.2 EXISTING & FINAL EQUIPMENT PLANS AREA OF CONSTRUCTION: EXISTING C-2 EXISTING & FINAL ELEVATIONS • PORTLAND PARK LATITUDE: 45' 26'29.40' (45.4415) C-3 EXISTING & FINAL ANTENNA PLANS Metzger LONGITUDE: -122' 44'38.30'(-122.7439722222) C-4 FINAL ANTENNA & CABLE SCHEDULE LAT/LONG TYPE (NAD 83) C-5 ELECTRICAL WIRING DIAGRAM _ Loll CURRENT ZONING: C-G C-6 EQUIPMENT DETAILS • JURISDICTION: CITY OF TIGARD C-7 EQUIPMENT DETAILS - OCCUPANCY CLASSIFICATION: U C-8 EQUIPMENT DETAILS Portland Wildwooc REV DATE DESCRIPTION TYPE OF CONSTRUCTION: IIB L A.D.A. COMPLIANCE FACILITY IS UNMANNED AND NOT FOR HUMAN G-1 GROUNDING SCHEMATIC .._. V,I;L�L RIDGE Community Natural ArE A 3/4/20 PRELIMS HABITATION G-2 GROUNDING DETAILS Fred Meyer 9 College S 0 3/18/20 FOR CONSTRUCTION - PROPERTY OWNER: PORTLAND GENERAL ELECTRIC ATTACHED PLUMBING DIAGRAM l':/' Sylvania 121 SW SALMON ST9 --- -PORTLAND, OR OR 97204 ; � TOWER OWNER: CROWN0DRPORE USA IncE •ii. 2 MPLTANCE - REVIEWED E s 2DDD CORPORATE DRIVE `\ .!r U) m CANONSBURG, PA 15317 - s '�Z i/1' `L PROJECT DESCRIPTION � lrn -a.6 Approved; [ �� CARRIER APPLICANT: AT&T TOWER ASSET GROUP ® • tp w TC: , 19801 SW 72ND AVENUE THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNA ® -9 Costco Wholesale ill "P a•� TUALATIN, OR 97062 MODIFICATION ON AN EXISTING WIRELESS SITE. • ill "Po/ TOWER SCOPE OF WORK {l PCrf7ljt #: "7t� r �. �.. CONTRACTOR TO MAINTAIN RRH TO BACK OF ANTENNA . _i "eEf AC CLEARANCE AS WELL AS 614 ANTENNA CLEARANCES PER LATEST ( sf( - S ""°9''� ' 7 I� I / -14''-AJ� AT&T RF GUIDELINES. Go:gle Ik Suits�data©2020 • INSTALL (3) ANTENNAS III / `��N • INSTALL (3) RRHs Q� NO SCALE B}: Aft Dv:: Li ' fV).-. PROJECT TEAM GROUND SCOPE OF WORK ' • REMOVE EXISTING +24V POWER PLANT APPLICABLE CODES/REFERENCE DOCUMENTS A&E FIRM: P. MARSHALL & ASSOCIATES • REMOVE POWER EQUIPMENT FROM EXISTING CONVERTER _ DESIGNED:EBG 1000 HOLCOMB WOODS PKWY STE. 210 SHELF, REMOVE CONVERTER SHELF; TRANSFER LOADS TO All WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE REFERENCE DOCUMENTS: DRAWN: EBG ROSWELL, GA 30076 NEW POWER PLANT WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE RFDS ID: 3586908 �/ '�PATRICK W MARSHALL, P.E. • INSTALL -48V EMERSON NETSURF 721 DC PLANT W/ (8) LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED CHECKED: PWM 678-280-2325 RECTIRERS, & (2) CONVERTER MODULES TO PERMIT WORK NOT CONFORMING TO THESE CODES: APPLICATION 10: 511775 CROWN CASTLE USA 1505 WESTLAKE AVENUE NORTH, SUITE 600 • RE-CONFIGURE (4) EXISTING +24V BATTERY STRINGS TO CODE TYPE 24RE INC. DISTRICT: SEATTLE, WA 98109 (2) -48V BUILDING 2019 OSSC JOB#: CONTACTS: KARIN JACKSON - PROJECT MANAGER BATTERY STRINGS FOR THE NEW POWER PLANT MECHANICAL 2019 OMSC kr•it V 4 i;" 20ACCATM06-0034 ELECTRICAL 2017 OESC �pyyc �{ TIGARD IX%RES:8/30/2020 (480) 735-6953 pp 4= by Planning PAUL LONG - CONSTRUCTION MANAGER VALIDITY OF PERMIT D> #- �_.� ?A TITLE SHEET & (206 (206) 388-9090 THE ISSUANCE OF A PERMIT LAURA MANSFIELD - A&E SPECIALIST (rill. PROJECT (720) 414-7271 BASED ON CONSTRUCTION INFORMATION AT&T CONTACT: JOSH DORNON DOCUMENTS AND OTHER 19801 SW 72ND AVENUE DATA SHALL NOT PREVENT CALL OREGON ONE CALL TUAATIN, OR 97062 NOTE; 4 (503) 569-7818 THE CODE OFFICIAL FROM I (800)332-2344 811 JD07250ATT.COM REQUIRING THE CORRECTION NOC ACCESSING/ENTERINGPRR TO MUST AT (BOO) 788-0 1 & CROWN CONSTRUCTION MANAGERCONTACT THE CROWN \' I) CALL 3 WORKING DAYS �V � T. BEFORE YOU DIG! OF ERRORS.ORSC 105.4 ' GENERAL NOTES: 1. EVERY EFFORT HAS BEEN MADE IN THE CONSTRUCTION DOCUMENTS TO PROVIDE A COMPLETE SCOPE OF WORK. MINOR ABBREVIATIONS 411.0w DISCREPANCIES IN THE DRAWINGS AND/OR SPECIFICATIONS SHALL NOT EXCUSE CONTRACTORS FROM COMPLETING THE �- AT&T PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. A/C AIR CONDITIONING MFR MANUFACTURER `�� 2. ALL REFERENCES TO OWNER HEREIN SHALL BE CONSTRUED TO MEAN THE CARRIER OR ITS DESIGNATED REPRESENTATIVE. AFF ABOVE FINISHED FLOOR MGR MANAGER AGL ABOVE GROUND LEVEL, MIN MINIMUM �.1� _ 3. BIDDING REQUIREMENTS ABOVE GRADE LEVEL MISC MISCELLANEOUS �� a. PRIOR TO THE SUBMISSION OF BIDS, VISIT THE JOB SITE TO BECOME FAMILIAR WITH ALL CONDITIONS AFFECTING THE AWS ADVANCED WIRELESS SERVICE NA NOT APPLICABLE PROPOSED PROJECT. VISIT THE SITE WITH THE CONSTRUCTION DOCUMENTS TO VERIFY FIELD DIMENSIONS AND BBU BATTERY BACKUP UNIT NIC NOT IN CONTRACT CONDITIONS TO CONFIRM THAT THE PROJECT WILL BE ACCOMPLISHED AS SHOWN. BLDG BUILDING NO NUMBER CROWN b. PROVIDE NOTIFICATION TO OWNER IN WRITING OF ANY CONFLICTS, ERRORS, OR OMISSIONS PRIOR TO SUBMISSION OF BLK BLOCKING NTS NOT TO SCALE CROWN 1tl ' PRICE PROPOSAL. IN THE EVENT OF DISCREPANCIES, PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS CLG CEILING OC ON CENTER CASTLE DIRECTED OTHERWISE. CLR CLEAR OD OUTSIDE DIAMETER v V II c. WHEN TOWER IS OWNED BY A THIRD PARTY, CONTACT TOWER OWNER REPRESENTATIVE FOR PARTICIPATION IN BID CONC CONCRETE PCS PERSONAL COMMUNICATION 1505 WESTLAKE AVENUE NORTH,SUITE BOO WALK. CONT CONTINUOUS SERVICE SEATTLE,WA 98109 d. WHERE ANCHORING TO A CONCRETE ROOF SLAB, CONFIRM (PRIOR TO SUBMITTING BID) THE PRESENCE OF POST p DEPTH PDU POWER DISTRIBUTION UNIT TENSION TENDONS. INCLUDE PROVISIONS FOR X—RAY PROCEDURES TO LOCATE THE TENDONS PRIOR TO CONSTRUCTION. DEL DOUBLE PROD PROJECP .k % DEC DEGREE PROP PROPERTY 4. DRAWINGS ARE NOT TO BE SCALED. WRITTEN DIMENSIONS TAKE PRECEDENCE. CONSTRUCTION DOCUMENTS ARE 0, DIA DIAMETER PT PRESSURE TREATEDINTENDED FOR DIAGRAMMATIC PURPOSES ONLY, LINO. DIAL DIAGONAL PVC POLYVINYL CHLORIDE DN DOWN RED REQUIRED ; A .w, 5. FIELD VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TO BEGINNING ANY MATERIALS ORDERING, DEf DETAIL RF RADIO FREQUENCY FABRICATION OR CONSTRUCTION WORK ON THIS PROJECT. BRING ANY DISCREPANCIES IMMEDIATELY TO THE ATTENTION DWG DRAWING RM ROOM P.MARSHALL&ASSOCIATES OF THE OWNER AND RESOLVE BEFORE PROCEEDING WITH THE WORK. E EXISTING RO ROUGH OPENING EA EACH RRH REMOTE RADIO HEAD 6. FURNISH ALL MATERIALS, EQUIPMENT, LABOR, AND ANY REQUIREMENTS NECESSARY TO COMPLETE PROJECT AS ELEV, ELELEVATION SHT SHEET DESCRIBED IN THE CONSTRUCTION DOCUMENTS. ELEC ELECTRICAL SIM SIMILAR EQ EQUAL SPEC SPECIFICATION 7. SUPERVISE AND DIRECT THE PROJECT DESCRIBED IN THE CONSTRUCTION DOCUMENTS. PROVIDE ALL CONSTRUCTION EQUIP EQUIPMENT SF SQUARE FOOT PT87 MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER EXT EXTERIOR SS STAINLESS STEEL THE CONTRACT. FIF FIBER INTERFACE FRAME, STL STEEL FACILITY INTERFACE FRAME SUSP SUSPENDED BU #: 874135 8. ALL WORK PERFORMED ON THE PROJECT AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL FIN FINISH TMA TOWER MOUNTED AMPLIFIER TIGARD NE APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, FLUOR FLUORESCENT TND TINNED RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY, MUNICIPAL AND UTILITY COMPANY FLR FLOOR TYP TYPICAL 10955 SW 65TH AVE SPECIFICATIONS, AND LOCAL AND STATE JURISDICTIONAL CODES APPLICABLE TO THE WORK. FT FOOT, FEET UMTS UNIVERSAL MOBILE TIGARD, OR 97223 GA GAUGE TELECOMMUNICATION SERVICE 9. CONSTRUCTION COORDINATION REQUIREMENTS GALV GALVANIZED UNO UNLESS NOTED OTHERWISE a. NOTIFY OWNER OF ANY DISCREPANCIES PRIOR TO START OF WORK. GC GENERAL CONTRACTOR VERT VERTICAL b. OBTAIN ALL PERMITS. SCHEDULE AND COORDINATE ALL INSPECTIONS. GRND GROUND W/ WITH c. PROVIDE, AT THE PROJECT SITE, A FULL, CURRENT SET OF CONSTRUCTION DOCUMENTS FOR USE BY ALL PERSONNEL GSM GLOBAL SYSTEM MOBILE W/O WITHOUT INVOLVED WITH THE PROJECT. GYP GYPSUM BOARD WCS WIRELESS COMMUNICATION d. RECEIVE WRITTEN AUTHORIZATION TO PROCEED WITH CONSTRUCTION PRIOR TO STARTING WORK ON ANY ITEM NOT HORZ HORIZONTAL SERVICE REV DATE DESCRIPTION CLEARLY DEFINED BY THE CONSTRUCTION DOCUMENTS. HR HOUR WP WATER PROOF A 3/4/20 PRELIMS e. PERFORM WORK DURING OWNER'S PREFERRED HOURS TO AVOID DISTURBING NORMAL BUSINESS. HT HEIGHT f. PROVIDE FALL PROTECTION IN ACCORDANCE WITH FEDERAL, STATE, LOCAL, AND OWNER REQUIREMENTS. ID INSIDE DIAMETER _ 0 3/1B/20 FOR CONSTRUCTION q. IF FAA LIGHTING AND MARKING IS PRESENT ON SITE AND IS POWERED BY ELECTRICAL SERVICE THAT IS TO BE IN INCH, INCHES INTERRUPTED, MAINTAIN THE NECESSARY LIGHTS DURING CONSTRUCTION AND NOTIFY THE PROPER AUTHORITIES IN INSUL INSULATION THE EVENT OF A DISRUPTION. INT INTERIOR h. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2—A OR 2—A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF PROJECT AREA DURING CONSTRUCTION. L LENGTH i. STRUCTURAL COMPONENTS OF ADJACENT FACILITIES SHALL NOT BE ALTERED BY THIS CONSTRUCTION PROJECT, UNO. LBS POUNDS ENSURE THAT EXCAVATION DOES NOT AFFECT ADJACENT STRUCTURES. LTE LONG TERM EVOLUTION j. SEAL ALL PENETRATIONS THROUGH FIRE—RATED AREAS WITH U.L. USTED OR FIRE MARSHALL—APPROVED MATERIALS, IF MAX MAXIMUM APPLICABLE. MECH MECHANICAL k. BURIED UTILITIES MAY EXIST IN THE AREA AND UTILITY INFORMATION SHOWN MAY NOT BE COMPLETE. CONTACT THE MTL METAL UTILITY LOCATE SERVICE A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION. I. COORDINATE ALL POWER INSTALLATION WITH POWER COMPANY AS REQUIRED. REPORT POWER INSTALLATION • COORDINATION SOLUTION(S) TO OWNER. m. PROTECT EXISTING IMPROVEMENTS, EASEMENTS, PAVING, CURBING, ETC. DURING CONSTRUCTION. UPON COMPLETION OF WORK, REPAIR ANY DAMAGE THAT MAY HAVE OCCURRED DUE TO CONSTRUCTION ON OR ABOUT THE PROPERTY. n. KEEP GENERAL WORK AREA CLEAN AND HAZARD FREE DURING CONSTRUCTION AND DISPOSE OF ALL DIRT, DEBRIS, AND RUBBISH. REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY OR PREMISES. SITE SHALL BE LEFT IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. — -- o. MAINTAIN THE INTEGRITY OF THE BUILDING ENVELOPE AND CONSTRUCT BARRIERS IN THE AREA OF WORK TO PREVENT DAMAGE FROM WEATHER AS WELL AS FROM CONSTRUCTION DUST AND DEBRIS. 10. INSTALL ALL EQUIPMENT AND MATERIALS ACCORDING TO MANUFACTURER'S SPECIFICATIONS, UNO, OR WHERE LOCAL DESIGNED:EBG CODES OR ORDINANCES DIRECT OTHERWISE. DRAWN: EBG 11. PROPOSED CELLULAR EQUIPMENT AND FIXTURES WILL BE FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR, CHECKED: PWM UNLESS NOTED OTHERWISE. 12. ANY SUBSTITUTIONS OF MATERIALS AND/OR EQUIPMENT, MUST BE APPROVED BY OWNER. qte40,,,t" JOB #.20ACCATM06-0034 EXPIRES:6/30/2020 13. DOCUMENT ALL CHANGES MADE IN THE FIELD BY MARKING UP THE APPROVED CONSTRUCTION DRAWINGS AND SUBMITTING THE REDLINED SET TO OWNER UPON COMPLETION. DOCUMENT ALL WORK PERFORMED WITH PHOTOGRAPHS TO BE SUBMITTED WITH REDLINED CONSTRUCTION DRAWINGS. 14. PROVIDE SUPPORTS FOR CABLES TO THE ELEVATION OF ALL INITIAL AND FUTURE ANTENNAS IN ACCORDANCE WITH ALL GENERAL NOTES MANUFACTURER'S REQUIREMENTS. "a. CONFIRM THAT THE REQUIREMENTS OF THE STRUCTURAL ANALYSIS, MOUNT ANALYSIS AND ANY ASSOCIATED MODIFICATIONS HAVE BEEN FOLLOWED AND COMPLETED AS REQUIRED TO SUPPORT THE EQUIPMENT ASSOCIATED WITH THIS PROJECT. T-2 1/4..4........0, ...........„ AT&T P Pn „z- _........____ ... _____ --cu"E CROWN NPPROXI ' nDN aC CASTLE z.i J I 1505 WESTLAKE NORTH,SUITE 800 SEATTLE,WA 98109 D IIIPIA Oo di=A P.MARSHALL&ASSOCIATES 1 DT87 BU #: 874135 EXISTING LANDSCAPE ? TIGARD NE J BUFFER TO REMAIN / EXISTING POWER 1 10955 SW 65TH AVE SUBSTATION / EXISTING SITE LOCATION o TIGARD, OR 97223 f - SEE SHEET C-1.2 FOR DETAILS 2 °-1 4 oI w Z Z 0 0.0 O a O wl REV. DATE DESCRIPTION a SUBJECT PARCEL: C l I A : 3/4/20 PRELIMS IO 1S136A00 ZONING: Coo CQ O 8 0 3/18/20 FOR CONSTRUCTION o. x n 0- F C-g CC6CD 6 /o a F C ro I o6' I ti f� m 6 :7:1 EXISTING CHAINLINK FENCE o ce ��y WITH BARBED WIRE L.L. q`F I I EXISTING ACCESS ROAD • I I DESIGNED:EBG DRAWN: EBG I CHECKED: PWM 414N Mgg JOB 6. IXO%6 R :IP6/30/2020 20ACCATM06-0034 NSNE PUN gSCAMER PROPERTY ONES MD SIRUCIUES HARE BEEN DIGITIZED MY JURISDICTIONAL GIS.CROWN CASTLE USA INC.HAS NOT COMPLETED A SUE TORS AC0 CYEOF 11A16 NO CUM A5 OVERALL SITE PLAN TO ACCURACY OF INFORMAOON DEPICTED ON THIS SHEET. W - — E OVERALL SITE PLAN '",".:. 1"=40' 0" (FULL j C-1 .1 SIZE) S 40 2C 0 ,.--��40' 1"=80' 0" 11x17 EXISTING AT&T ICE BRIDGE 4.1111110 .z.........„01,... AT8ET EXISTING SLACK BOX EXISTING ) CO FEEDLINES CROWN (13) COAX CABLES " \��\ EXISTING AT&T ".I CASTLE EXISTING COAX PORT - (6) DC TRUNKS 11'-6" x 28'-0" ENTRY \\ - (2) FIBER TRUNK EQUIPMENT SHELTER DOOR \ - (1) RET I 1505 W ESTLAKE AVENUE NORTH,SUITE 800 _ , SEATTLE,WA 98?09 1 — EXISTING ARGUS +24V DC EXISTING. EXISTING I PLANT TO BE REMOVED BATTERY BATTERY I411 a .CABINET. CABINET IIO A HVAC p. ¢ P.MARSHALL&ASSOCIATES _ i EXISTING RACK W/ (2) RAYCAP DC12 (LTE) (2) -48V CONVERTER SYSTEM, FSM4, RACK EXISTING MOUNTED SLACK TRAY CCU RACK - EXISTING CABLE LADDER �T8 7 m 1 \ , BU #: 874135 o EXISTING EXISTING TIGARD NE HVAC NDKIA GSM NOKIA I" CABINET UMTS 10955 SW 65TH AVE (RETIRED) CABINET .____- TIGARD, OR 97223 ROSE[ EXISTING EQUIPMENT PLAN EOUIPMENT LAYOUT SHOWN IS BASED ON THE PRE\OUS ., 1" 2'-0" (FULL SIZE) CONSTRUCTION DRAT/RAGS DONE EY VELOCITEL,LLC REV DATE DESCRIPTION _ DATED 8/27/1s AS WELL AS MOST RECENT AUDIT 2 1 0 2� 1"=4'-0" (11x17) PHOTOS AND MEASUREMENTS.IF EQUIPMENT LAYOUT DIFEERs FROM WHAT IS SHOWN,CONTRACTOR TO / A 3/4/20 PRELIMS CONTACT THE CONSTRUCTION MANAGER. EXISTING AT&T ICE BRIDGE %\ 0 3118/20 FOR CONSTRUCTION EXISTING SLACK BOX TING AT&T EXISTING AT&T FEEDLINES EXIS 11 EXIS x AT&T -., - (13) COAX CABLES RE-CONFIGURE (4) EXISTING +24V EQUIPMENT SHELTER \\ EXISTING COAX PORT - (6) DC TRUNKS BATTERY STRINGS TO (2) -48V BATTERY . ENTRY \ - (2) FIBER TRUNK STRINGS FOR THE NEW PP DOOR \ - (1) RET 1 REMOVE POWER EQUIPMENT FROM EXISTING PROPOSED -48V EMERSON NETSURE 721 DC PLANT EXISTING EXISTING -- CONVERTER SHELF, REMOVE CONVERTER SHELF; W/ (8) RECTIFIERS, (2) CONVERTER MODULES BATTERY BATTERY TRANSFER LOADS TO NEW POWER PLANT w __ CABINET CABINET Q HVAC a (2) -48V CONVERTER. SYSTEM,FSM4, RACK DESIGNED:EBG MOUNTED SLACK TRAY - DRAWN: EBG EXISTING //� EXISTING (1) FSM4.(AMIA) IS ADEQUATE, REMOVE SPARE (1). _, _ ` ccu / ASIA & (1) ABTA.FROM C2 SIDE OF EXISTING FSM4.(AMIA). . �� CHECKED: PWM RACK /// UIIULE EXISIINU.(1) ASIA AND (S) ABIA CARUS UN-IHE Cl _.+� . `/ lr SIDE FOR LTE ADD 5G GROWTH KIT ON THE C2 SIDE FOR 5G _ p, N�M1M�,'�c JOB): --,� �\ EXPIRES.6/30/2020 ' 20ACCATM06-0034 EXISTING CABLELADDER o \ \ r (TYP.) p EXISTING EXISTING NDKIA GSM NOKIa HVAC EXISTING & FINAL CABINET UMTS ((RETIRED) CABINET INSTALLFRNOTE; EQUIPMENT PLANS CROWN CASTLE HAS BEEN INFORMED BY THE CARRIER THAT THE REMOVAL OF THE --'-'— - EXISTING EQUIPMENT AND REPLACEMENT WENT NEW EQUIPMENT WALL NOT INVOLVE ANY MODIFICATION OR UPGRADES TO THE EXISTING AC ELECTRICAL SYSTEM AND THAT THE PROPOSED EQUIPMENT WILL UTILIZE THE SAME BREAKER,WIRE.AND CONDUIT THAT FINAL EQUIPMENT PLAN WAS USED FOR DIE EQUIPMENT BEING REPLACED.THE CONTRACTOR IS TO NOTIFY THE ENGINEER OF RECORD IF ANY ELECTRICAL MODIFICATIONS TO THE EXISTING AC 1"=2—O_ (FULL SIZE) ELECTRICAL bEILM ARE NECESSARY FOR THE REQUESTED WORK TO BE PERFORMED. 2 1 U ;:.:.2' 1"=4'-0° (11x17) C-1 .2 I CONTRACTOR TO ENSURE THAT ALL AT&T TOWER MOUNTED EQUIPMENTRODIS BELOW THE TOWER LIIS N BEACON & AT&T COMPLIANT WITH ALL REGULATORY REQUIREMENTS. THE FAA APPROVED HEIGHT FOR THIS SITE IS Not ReENT CONTRACTOR TO REFER TO THE TOWER STRUCTURAL ANALYSIS �-� FOR THIS PROJECT BY OTHERS. �� EXISTING AT&T EQUIPMENT TO REMAIN CROWN - (6) ANTENNAS CASTLE - (15) RRH EXISTING AT&T EQUIPMENT TO REMAIN GIC - (3) DC6-48-60-18-8F RAYCAP SQUID - (6) ANTENNAS - (15) RRH 1505 WESTLAKE AVENUE NORTH,SUITE 800 - (3) DC6-48-60-18-8F RAYCAP SQUID SEATTLE,WA 98109 • �L n I— A .,.... i p P.MARSHALL&ASSOCIATES AT&T EQUIPMENT TO BE INSTALLED ' - (3) COMMSCOPE NNHH-65C-R4 ANTENNAS - (3) NOKIA RRH 4T4R B5 160W AHCA - (6) FIBER JUMPERS, 2 PER PROPOSED RRH 1 T87 11 BU #: 874135 ii TIGARD NE I 10955 SW 65TH AVE _1 _I [ TIGARD, OR 97223 CD CD a J J I O ¢ O I EXISTING CARRIER _ I EXISTING CARRIER IL Il _IL ANTENNAS TYP. b O ( ) O O ANTENNAS (TYP.) I O I O REV DATE DESCRIPTION p II 00 II - A 3/4/20 _. PRELIMS W ---- W .-- '---- "I - 0 3/18/20 FOR CONSTRUCTION Z a-, Z II J .r .c 'Tr 'It' II = °v^ v 'r z 11 ZII I I- U O- U CD Q . CD Q Z Z Z Z I- Z I= Z - W W ¢ EXISTING MONOPOLE W ZQ EXISTING MONOPOLE • 0 0 0_ Q 0_ Q EXISTING AT&T FEEDLINES O- CD EXISTING AT&T FEEDLINES Z - (13) COAX CABLES Z - (13) COAX CABLES - (6) DC TRUNKS ♦- - (6) DC TRUNKS (2) FIBER TRUNK (/_ W - (1) RET X - (2) FIBER TRUNK W - (1) RET DESIGNED:EBG Az Ara DRAWN: EBG EXISTING AT&T EXISTING AT&T CHECKED: PWM EQUIPMENT EQUIPMENT J03 if: 20ACCATM06-0034 EX%RES:6/30/2020 ♦•;: ♦:**::*i♦i�0•♦♦�♦♦♦r *iIt • `«iri••0*•%i• :rt_ •Oi0•*XOOOi V:.,;♦'gJ♦ 0 O♦♦O�«SS*:;:;:♦♦O'�0;:44, '♦ t: •*AI:i0O k:SS:V 1 • O.♦♦6♦i•♦O♦•ii ♦009.0;• ::: ♦;♦�O:Y�♦♦«•♦O ;♦4.*::::O•II•O•♦•04i•♦•:00•� "O♦• '':%::::: 4::::::: - •00♦0i . iii•Oi••O•• S•••O•• ••• ♦0•0*0,?o♦O•�•♦O♦O¢00 ♦• EXISTING 8� FINAL ;m0• . .04P*V •••: ♦ `••:S•;••ti°o: .4. °•°',•'•••o• :+:4+:4. .>♦ vo......s♦• O ELEVATIONS O•♦♦•• •0•,I.�„00 O¢.O coo %♦O♦ ♦♦ O♦•••Z•.:":"0••••OO•,,..• �y•,%v..•��•••:J:m... .. Oii• •6 ii ♦04' ♦f j 00O♦•♦O•O♦•i i 00 ♦•♦O•♦Ji ♦•♦•�♦O♦ 'Y♦♦ O ♦ ♦♦♦00 Od!♦i ♦♦♦' �• • • , •♦C,O �Oaj.♦♦♦♦O� � ♦♦00♦♦•ii♦0♦♦♦♦,♦♦♦...� �•r.��33'';O♦O.•i♦Oi••♦•♦•♦♦O•♦ ♦• ♦9.♦�.. ��Oi.♦.♦.w@i.0i--i♦O< ��. - e._♦es w.♦9.♦.s.�acaa. ♦ • • • • • - EXISTING WEST ELEVATION FINAL WEST ELEVATION C-2 NOT TO SCALE NOT TO SCALE ,�`-�. EXISTING PLATFORM `C\ MOUNT TO REMAIN ` AT&T A4 EXISTING AT&T RRH TO REMAIN 1.TE�� �/ NOKIA B66A RRH4X45-4R ;d - (TOTAL OF 3, 1 PER SECTOR) , J� 61 80 11 CROWN - 0.. EXISTING AT&T RRH TO REMAIN 1 NOKIA RRH2X40-07L-AT 0:: CASTLE (TOTAL OF 3, 1 PER SECTOR) y11D1, 1505 WESTLAKE AVENUE NORTH,SUITE 800 ��! ' SEATTLE,WA 98109 EXISTING AT&T ANTENNAS TO REMAIN ti"� h � } 1• EXISTING AT&T RRH TO REMAIN KATHREIN - 80010866p t Bt1@nl NOKIA RRH 4T4R B14 160W FRBI (TOTAL OF 1, ALPHA SECTOR) ` �• O n (TOTAL OF 3, 1 PER SECTOR) Al � i ,� nl Mi . A04 EXISTING AT&T RRH TO REMAIN T1% O NOKIA B25 RRH4X30-4R , ,yi ' _ WO ® i. w (TOTAL OF 3, 1 PER SECTOR) 4 .• p' ,14 P.MARSHALL&ASSOCIATES `---, - .. _ . 4-t-! EXISTING AT&T ANTENNAS TO REMAIN .F -1'-' KMW EPBQ-654L8H8-L2 71), `f. �� v*y,, ;j (TOTAL OF 3, 1 PER SECTOR) u1111- ?` 1111111y ca • 1 1 EiE� / -/ � � `1'I, A;� B4 - B0. PT8 7 1 4 BU #: 874135 MR EXISTING AT&T RAYCAP TIGARD NE DC6-48-60-18-SF TO REMAIN EXISTING AT&T RRH TO REMAIN (TOTAL OE 3. 1 PER SECTOR) G1 NOKIA RRH4X25-WCS-4R 10955 SW 65TH AVE to (TOTAL OF 3, 1 PER SECTOR) TIGARD, DR 97223 EXISTING AT&T ANTENNAS TO REMAIN �u•/ COMMSCOPE - JAHH-65C-R3B-V3 '4,m (TOTAL OF 2, 1 PER BETA & GAMMA SECTORS) 1 NOTE: N EQUIPMENT LAYOUT SHOWN IS BASED ON THE PREVIOUS CD EXISTING ANTENNA PLAN CONSTRUCRON DRAWINGS DONE BY vELocna.uc NOT TO SCALE DATED B/27/18 AS WELL AS MOST RECENT AUDITREV DATE DESCRIPTION PHOTOS AND MEASUREMENTS. IF EQUIPMENT LAYOUT DIFFEXa FROM WHAT 6 SHOWN,CONTRACTOR TO A 3/4/20 PRELIMS CONTACT THE CONSTRUCTOR MANAGER. \ EXISTING PLATFORM �;, MOUNT TO REMAIN 0 3/18/20 FOR CONSTRUCTION EXISTING AT&T RRH TO REMAIN `6•\ EXISTING AT&T ANTENNAS TO REMAIN NOKIA B66A RRH4X45-4R COMMSCOPE - JAI-IH-65C-R3B-V3 (TOTAL OF 3, 1 PER SECTOR) A4 (TOTAL OF 2, 1 PER BETA & GAMMA SECTORS) LTE__,. PROPOSED AT&T ANTENNAS /�%b j42 EXISTING AT&T RRH TO REMAIN COMMSCOPE - NNHH-65C-R4 RR i. RyO NOKIA RRH2X40-07L-AT klii (TOTAL OF 3, 1 PER SECTOR) �.l� 4. ,;yi�. (TOTAL OF 3, 1 PER SECTOR) �Q • �d i� LTE. �ii'Ao• Gp g0• EXISTING AT&T ANTENNAS TO REMAIN "i `� ,yqy y�►t2 - 7 KATHREIN - 80010866IR ' d� 41I 1 (TOTAL OF 1• , ALPHA SECTOR) '..".•,:* ' 407 n 1 NOTES Al iy � ." / EXISTING AT&T RRH TO REMAIN DO NOT INSTALL RAYCAPS OR RRUS IN A MANNER THAT INFRINGES INin 1 • EXISTING AT&T RRH TO REMAIN I�Ilnntl NOKIA RRH 4T4R B14 160W FRBI UPON THE TOWER SAFETY CLIMB. 1V1nlln (TOTAL OF 3, 1 PER NOKIA 625 RRH4X30-4R 's �Innnn SECTOR) • THE CONTRACTOR SHALL OBTAIN THE FINAL RFDS PRIOR TO �' - vim ' (TOTAL OF 3, 1 PER SECTOR) � ?o� _ tippet CONSTRUCTION. �'- �n11neN1 DESIGNED:EBG • CONTRACTOR TO CONFIGURE ALL RAYCAP SQUID ALARMS ACCORDING TO A .�wt, ,�2 EXISTING AT&T ANTENNAS TO REMAIN THE NUMBER OF RADIOS INSTALLED, FOLLOW MFR'S SPECIFICATIONS. � '� - 1ST SQUID INSTALLED WILL BE ALARMED TO LOWEST - � _, .• ,.I.+►` :-' KMW EPB0-654L8H8-L2 �� DRAWN: EBG BAND RRU TO THE ALPHA SECTOR. i� e ��� '� ;' (TOTAL OF 3, 1 PER SECTOR) p CHECKED: PWM - 2ND SQUID INSTALLED WILL BE ALARMED TO LOWEST �► �zc' �,� a� BAND RRU TO THE BETA SECTOR. G4 ~' _-.. il t Ile 1 OE �'' - 3RD SQUID INSTALLED WILL BE ALARMED TO LOWEST �,ice.; - � d08 . BAND RRU TO THE GAMMA SECTOR. �r "$ c, U!"'- �80' 20ACCATM06-0034 W/ �.� 1, i y B4 EXPIRES:B/3f1/DOUR - SQUID ALARMS ARE NET TO BE DAISY CHAINED. �Ta . �°, -4. 11 a04-, \‘ G2 EXISTING AF TO RAYCAPEMAIN IS EXISTING AT&T RRH TO REMAIN EXISTING & FINAL DC6-48-60-18-8F TO REMAIN /t G1 NOKIA RRH4X25-WCS-4R (TOTAL OF 3, 1 PER SECTOR) 1 / (TOTAL OF 3, 1 PER SECTOR) ANTENNA PLANS PROPOSED AT&T RRH 1 ,toNOKIA RRH 4T4R 65 160W AHCA JT 0' (TOTAL OF 3, 1 PER SECTOR) 1 N FINAL ANTENNA PLAN C-3 NOT TO SCALE FINAL EQUIPMENT SCHEDULE AT&T (VERIFY WITH CURRENT REDS) ALPHA ANTENNA RADIO DIPLEIRR TW SURGE PROTECTION CABLES POSITION TECH. STATUS/MANUFACTURER MODEL AZIMUTH RAD CENTER OTT. STATUS/MODEL LOCATION OTY. STATUS LOCATION 01T. STATUS/MODEL OTT. STATUS/MODEL 01T. STATUS/ITPE LENGTH 1 (E)RRH2X40-0IlAT 2 (E)COAX 120'-0' CROWN Al LTE (800A0866" 330' 99' TOWER - - - - - - - CE41:10 CASTLE 1 (E)B25 RRH4X30-4R 1 (E) RET 120'-0' 1505 WESTLAKE AVENUE NORTH,SUITE 800 SEATTLE,WA 98109 A2 LTE (P)COMMSCOPE 331T 99' 1 (P)ItoH 4T4R B5 160W AHCA TOWER _ - _ _ - _ - -NNHH-65C-R4 - - A3 _ _ - _ _ _ _ _ _ _ _ _ _ - _ _ _ • O , I (E)RRH 4T4R 814 160W TRBI TOWER 2 (E)COAX 120'-0' J A4 LTE (E)08W 330' 99' 1 (E)8664 RRH4x25-WCS-4R TOWER - - - - - 1P.MARSHALL&ASSOCIATES EPB9-654L648-12 (E)OC6-48-60-18-BF I (E)FIBER 120'-0' 1 (E)RRH4X25-WCS-4R TOWER 2 (E)DC 120'-0' BETA I (E)R12412X40-07LAT P T 8 7 B1 LTE COCOMMSCOPE BO' 99' TOWER - - - - - - - JAHH-650-R38-V3 I (E)825 RRN4%3O-SR 3 (E)COAX 120'-0- BU #: 874135 B2 LIE (P)CCIANSCOPE 80' 99' I (P)RRH 4T4R B5 160W MICA IOWEN _ _ _ _ - TIGARD NE NNHH-65C-R4 - - - - 10955 SW 65TH AVE TIGARD, DR 97223 B3 - - - - _ - _ _ - - _ - _ _ _ - - I (E)RRH 4T4R B14 160W TRW TOWER • 2 04 LEE (E)MOW 80' 99' t (E)B66A RRH4E2E-WCS-.RR TOWER - - - - - 1 (E)COAX 120'-0" EP�_834L8118-U (E7 DC6-46-60-18-8F I (F)RRH4X25-WCS-4R TOWER 2 (E)DC , 120.-0- REV DATE DESCRIPTION A 3/4/20 PRELIMS 0 3/18/20 FOR CONSTRUCTION GAMMA 1 (E)RRH2X40-07LiT GI LTE (E)COMMSCOPE 195' 99' TOWER - - - - - - - 2 (E)COAX 12D'-0' JAHH-650-R38-V3 I (E)825 RRH4X30-4R G2 LTE (P)COUMSCOPE 195 99' 1 (P)RRH 4T4R 85 160,11 MICA TOWER _ _ _ _ _ _ _ _ _ -- --- NNHH-65C-R4 • .G3 _ - - - - _ _ _ _ - - _ - - _ _ _ I (E)RRH 4T4R B14 16074 TRW TOWER 2 C4 LIE EPBOO MAW 195' 99' 1 (E)866A RRH4x25-WCS-4R TOWER - - - - - 1 (E)DC6-48-60-18-SF 1 (E)FIBER 120'-0- 1 (E)RRH4X25-WCS-4R TOWER 2 (E)DC 120'-0' . NQTE: (E) -D(ISIING (P) -PROPOSED Voltage Drop Calculations _ DESIGNED:EBG Wane(yI AOp w = 48 eraOe = t0.00 I Tenperature('C)= TS J CABLE COUNT -� � 5b ''. DRAWN: EBG « Paws Rent to DC-6(Junper) DC-6 to Souk((Trunk) Squid to RRH (Jumper) Final Voltage Total Voltage Sect rube Sie Wm Length(N R Oka) Voltage Drop 'Mre Sint Wins Length(0) R(SPAN) Voltage Drop Wire See Wire Length(TM R(DAdt) Voltage Drop 0) Drop(%) OTT CABLE TYPE CHECKED: PWM ri el ii Ape. 12 15 1.9800 0.5940 8 120 0.7780 1.8872 12 15 1.9800 0.5840 44.94 6.37 13 COAX CBE �1��A!� JOB#: 4. Bad 12 15 1.4800 0.5940 6 120 0.7780 1.6872 12 15 1.9800 0.5940 44.94 8.37 6 DC TRUNK �'4^1'✓•-+''^' YY 2OACCATM06-0034 Genre 12 15 1.9800 0.5840 8 120 0.7780 1.8672 12 15 1.9500 0.5940 44.94 6.37 2 FIBER IRON( FXRWE6:6/30/2020 NOTES. 1.CALCULATIONS ARE BASED ON STRANDED,COPPER CONDUCTORS. 2.RESISTANCE VALUES FOR CONDUCTORS ARE BASED ON TABLE 8 OF THE NEC.DIRECT-CURRENT RESISTANCE FOR CONDUCTORS. 3.LENGTH SHOWN IS TIE LENGTH ONE-WAT TO DEVICE. FINAL ANTENNA & CABLE SCHEDULE NOTES: 1.REFER TO FINAL REDS FOR FINAL RF CONFIGURATION. FINAL ANTENNA & CABLE SCHEDULE 2.REDS ID 3586908 BEING USED. C 4 TO ANTENNAS 40MINIIMIOAT&T (PER SECTOR) / (4)COAX JUMPERSMP) 111 III III _I __ _ . MP) PER SECTOR Cj. CROWN _PE 7DD v CASTLE LTE WCS LTE 700 LTE B50 LTE PCS _'E AWE FIRSTNET 1505 WESTLAKE AVENUE NORTH,SUITE 800 • • • _.LA • • • • • • • SEATTLE,WA 98109 RRH 866A- RRH RRH RR- RRH :;. O AHNA RRH4x45 2z60-950 2x40W-07L 2z40W-07L RRH , v 1 T 1 r FIBER JUIdPER PAIRS -M v I'. — r O P) L11 L-- - J " , P.MARSHALL&ASSOCIATES -0P /1 F SQUID .. ___ p rl -- It ALARM CABLE P F F (1"F) L F F F P P P _II P P P P • F F F P P P P ``_\ --P `EXISTNG DC JUMPERS SET OF(2)DC JUMPERSPT8 7 1� a s u MP) CONDUCTOR BUNDLES NEW DC JUMPERS n (SIP) (TYP) 11111111-111 11 111 ILL DC/FIRER DC/FIBER BU #: 874135 r -0v DEMARCATION BOX DEMARCATION BOX T GARD NE - - - 10955 SW 65TH AVE CET of(2)DC ---DC POWER TRUNKS TIGARD, OR 97223 CONDUCTOR BUNDLES F F ( P p P ttP) P REVUC BUS INSIDE P— EXISTING DC TRUNKS P P P EXISTING POWER PLANT P P (TYP) DC JUMPERS(TYP) Lr —I v (VERIFY EXISTING OR INSTALL NEW) ALARM a C p P RACK MOUNTED SURGE REV DATE DESCRIPTION ' PROTECT/DC POWER A 3/4/20 PRELIMS C RACK MOUNTED SURGE r SUPPRESSOR 0 3/18/20 FOR CONSTRUCTION Mill C ' F F RACK MOUNTED BBU RACK MOUNTED SURGE PROTECT/DC POWER I I ___ —_ POWER PLANT _ \-DC 6 i —--— JUMPER RRH DESIGNED:EBG JUMPER TRUNK : � DRAWN: EBG POWER PLANT DC-6 SQUID RRH II CHECKED: PWM RRH NOTES: -.__'.'„e JOB #: EXPIRES:8/30/202• 20ACCATM06-0034 1. REFER TO CHART FOR CABLE QUANTITIES,SIZES, AND LENGTHS. ODC WIRING DIAGRAM (PROVIDED BY OTHERS) ELECTRICAL WIRING SCALE: NOT TO SCALE DIAGRAM C-5 ...... 1 AT&T CrCROWN CASTLE 1505 WESTLAKE AVENUE NORTH,SUITE 800 SEATTLE,WA 98109 >18" >I8" _. ANTENNA MOUNT PIPE (TYP.) ANTENNA MOUNT PIPE (TYP.) . O i RRU SUPPORT Q DOWNTILT BRACKET SUPPLIED WITH ANTENNA (TYP.) WITH ANT WITHDOWNTILT ANT BRACKET SUPPLIED P.MARSHALL&ASSOCIATES ENNA (TYP.) BRACKETS U-O 11-11 (TYP.) RRU SUPPORT �� BRACKETS � �`� RRUS II H PT87 (TYP.) _. Mil BU #: 874135 RRUS TIGARD NE 10955 SW 65TH AVE `° TIGARD, OR 97223 •_• LTE ANTENNA (TYP.) . LTE ANTENNA (TYP.) ' REV DATE DESCRIPTION �+� A - 3/4/20 PRELIMS 111 N .. 0 3/18/20 FOR CONSTRUCTION •l• .. •I MOUNTING BRACKET SUPPUED MOUNTING BRACKET SUPPLIED WITH ANTENNA (TOP.) WITH ANTENNA (TYP.) ANTENNA & RRU DETAIL NOT TO SCALE - • • DESIGNED:EBG DRAWN: EBG CHECKED: PWM m JOB #: IXpRts;e/bD/2fY20 20ACCATM06-0034 EQUIPMENT DETAILS C-6 mm MANUFACTURER: Co scope MANUFACTURER: NOKIA MODEL: NNHH-65C-R4 MODEL: AHCA (AIRSCALE 4T4R B5) HEIGHT: 96" (2738 mm) HEIGHT: 13.3" 337 mm) ra. WIDTH: 19.6'7.8" 978 m) WIDTH: 6.5" �655 mm AT&T DEPTH: 7.8" (197 mm) DEPTH: 6.5" (165 mm) ,. WEIGHT: 100.3 lbs (45.5 kg) WEIGHT: 35.27 lbs (16 kg) VENDOR: COMMSCOPE' MODEL: RR-FA2 �� WEIGHT: 35.88 LBS Fk —Al WIDTH al":10 CROWN ]< >7 c : o t� CASTLE �" BRACKET /3Y/�REAR ID/\ r n n L 1505 WEST AKE SEATTLE,WA 98109NUE H,SUITE 800 14" GALV FLAT /�; 1 1 f� J.�\ \ WASHER J 14"x 115" GALV Al,' 14E GALV �� I1 BOLT KIT HEX NUT 0 ,� LV I OCKAWASHER pt."' i 0.44'0, TYPvs: WELDED FRONT °..a 1.1 BRACKET P P.MARSHALL&ASSOCIATES III LEF! RRH HANGER, / _ TYP 2 !zp °::",:- 'o ' J4"x 114" GALV 52 THREADED ROD I = RF CONNECTIONS . I 9 �TQ 7 WIDTH lLJl 1 RIGHT RRH HANGER, TYP 2 BU #: 874135 TIGARD NE al ✓ 10955 SW 65TH AVE FCTION A-A of TIGARD, OR 97223 °Commscope NNHH-65C-R4 °DUAL MOUNTING BRACKET - HD °NOKIA AHCA (AIRSCALE 4T4R B5) NOT TO SCALE NOT TO SCALE NOT TO SCALE REV DATE DESCRIPTION A 3/4/20 PRELIMS 0 3/18/20 FOR CONSTRUCTION ;, DESIGNED:EBG DRAWN: EBG CHECKED: PWM or \ JOB#: 20ACCATM06-0034 EXPIRES 6/30/2020 EQUIPMENT DETAILS °NOT USED ONOT USED 0 NOT USED C�7 NOT TO SCALE NOT TO SCALE NOT TO SCALE 4....„.....0 375" 20,13 AT&T �� °ids•. CROWN L::C CASTLE 1505 WESTLAKE AVENUE NORTH,SUITE 800 SEAITLE,WA 98109 ,I „UD I 2.I}" 1111,11-° i P.MARSHALL&ASSOCIATES REFER TO SCOPE OF WOW ON SHEET C-1 FOR REWIRED QUANTITY OF RECTIFIERS MID OR/CONVERTERS FOR PROPOSED EWING PT87 1, , BU #: 874135 ' TIGARD NE �_ �" �� _. ° ICI ° • ® 10955 SW 65TH AVE TIGAR'1 0955 , OR 97223 DISIPoBIIION awe aaeaaea li ° CABINET eeeee°ee 0 0 ® �(ss;��% REV DATE DESCRIPTION p}'% �'J CONTROLLER OM A 3/4/20 PRELIMS -. - &Y111 13 0 3/18/20 FOR CONSTRUCTION 1 ®. —�-- RECTIFIER MODULE�: g<=i)), PROPOSED 1/2•DIAMETER,NOMINAL EMBEDMENT SENT(IClC STRUNG-BOLT 2 WEDGE --- A■pp ANCHOR WITH 3-3 4 NOMINAL EM3ECMEM'IOC ESR-3037 TO RE • =�==- INSTALLED A MINIMUM OF NT IN EACH CORNER OF GBNEC SEE MANUFACTURER'S EQUIPMENT INSTALLATION MANUAL FOR ANCHOR 114 LOCATIONS.IT IS ASSUMED THAT CABINET ANCHOR LOCATIONS HAVE BEEN �. • DESIGNED/REINFORCED BY THE MANUFACTURER TO WITHSTAND SHEAR AND UDLIFT FORCES AS CALCULATED IN THIS DESIGN _ • • 7 EQUIPMENT • LOCK BASE FRAME --- - • • • WASHER / PLATE• / • .• WASHER • III I . • c .0 OM PI/�/�//////////1L//// n A • d = A n ° DESIGNED:EBG . • 0 0 0 _ .. `- G ° A .0 d ' DRAWN: EBG • • ' \ a F. `� A r da E CHECKED: PWM �A �� OPTIONAL fiA7HAcK ° aMy¢ a n a -? , ,� • U 0 o 5--- p A a o�. d °. ExPIRES:s/.w/2020 20ACCATM06-0034 ____------ \�/ CONCRETESLAB EQUIPMENT DETAILS VERTIV — NETSURE 721 POWER PLANT CABINET ANCHOR DETAIL SCALE: NOT TO SCALE SCALE: NOT TO SCALE C-8 I ., AT&T s .,„.,.______....,, ,d4o,1 N1 EXISTING AT&T GROUND BAR C tat n,,,,II CROWN =•r. °u!!' a: CASTLE 4 4 i � 1 1505 WESTLAKE AVENUE NORTH,SUITE 800 V m11m�u t e s 7 SEATTLE,WA 98109 i'll '' '4." ni w' 0 s 4 41 i �� P.MARSHALL&ASSOCIATES �y,« ip s\11!;;;,1110 UN11lV if 44 �y GROUNDING NOTES: P 8 7 milt 1. PROPOSED2 AWG STRANDED GREEN INSULATED COPPER WIRE FROM THE TOWER MOUNTED RAYCAP BU ll; 874135 DC6 OR DC9 TO THE SECTOR GROUND BAR. TIGARD NE GROUND PER MFR'S SPECIFICATIONS. PROPOSED #2 AWG SOLID BARE TINNED COPPER WIRE FROM ALL NEW 1 O9SS SW 65TH AVE RAYCAP SQUIDS. RRU's. TMA's, DIPLEXERS AND PIPE MOUNTS TO THE 2. PROPOSED #2 AWG STRANDED GREEN INSULATED EXISTING GROUND BAR. GROUND PER MANUFACTURER'S SPECIFICATIONS. COPPER WIRE FROM EACH TOWER MOUNTED RRU TO TIGARD, OR 97223 THE SECTOR GROUND BAR. GROUND PER MFR'S GROUNDING SCHEMATIC AT TOWER SPECIFICATIONS. 3. GROUND ALL RF EQUIPMENT INCLUDING BUT NOT GROUNDING KEY NOTES: UMITED TO COAX, DIPLEXERS, SURGE ARRESTORS, n PROPOSED #2 AWG STRANDED GREEN INSULATED COPPER WIRE '`j6.-4,' ���•�•, TMA's, RRU's ATT-AS, & ANTENNA MASTS PER � _ ��� NEC AND AT&T ATT-TP-76416. REV DATE DESCRIPTION FROM THE PROPOSED DC PLANT TO THE EXISTING MAIN GROUND �.• : A 3/4/20 PRELIMS BAR. GROUND PER MANUFACTURER'S SPECIFICATIONS. . . �� • ' 4. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL . 1I METAL BOXES, FRAMES AND SUPPORTS SHALL BE 0 3/18/20 FOR CONSTRUCTION '.:��♦�,� 4 BONDED TO THE GROUND RING, IN ACCORDANCE - -- _.- _ �♦♦♦ � WITH THE NEC. •,®��•�� 5. WIRE FROM ALL METAWC CROPOSED #2 AWG SOLID ONDO TSE NTO THE ED PPER ��.�� • EXISTING GROUND RING. USE BURNDY GAR SERIES 1 �:♦� CLAMPS TO CONNECT TO CONDUIT rL.' : — PROPOSED -48V EMERSON NETSURF 721 DC PLANT DESIGNED EBG WI (8) RECTIFIERS, (2) CONVERTER MODULES a` DRAWN: EBG WilCHECKED PWM Wmgh _Arte,Ai JOB)': \ Ezriacs<s/ao/m7o 20ACCATMO6-00 34 \ GROUNDING SCHEMATIC GROUNDING SCHEMATIC AT GROUND G-1 �I� TO ANTENNA COAX �JI TO ANTENNA COAX WIRE SIZE BURNDY LUG BOLT SIZE - COPPER/GALVANIZED CROJnO BAR /// COPPCR/GALVAN.ZED GROAN)BAR $6 GREEN INSULAILO VAAC-2TC38 3/6'- TB NC SS 2 BOLT \ /,...‘...„...., AT&T / / �_�I t 92 SOLID TINNED YAOC-2TC3d 3/e"- 16 NC SS 2 BOLT 0 0 00.........0 O O O O O O O O O O O O o 0 o #2 STRANDED YA2C-2TC38 3/H"- 16 NC 55 2 BOLT O O O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 E 0 c o o 000000 00000000000 Pi O O O O O O 0 0 0 0 0 0 0 0 0 0 0 ® $2/0 STRANDED VA26-2 C3W 3/6"- ifi NC 55 2 BOLT $4/D S1 BANDED YA26-2N 1/2'- 16 NC SS 2 BOLT $2 SOLID TINNED COPPER CONDUC-CR TO TOWER/SHELTER GROUND RING(2 BURROS GROUND LUG W/ LONG BARREL HEAL SHRINK TWO HOLE LONG BARREL COMPRESSION TWO HOLE LONG BARREL COMPRESSION LUG(TYP) UP.FOR BO'TOM GROUND BAR ONLY) (REF CHART) (CLEAR) CROWN LUG(TYP) NUT(TYR)- IOC,(WASHER(TYR) (X2 CASTLE NOTES NOTES. I. DOUBLING UP"DR STACKING'OF CONNECTIONS IS NOT PERMITTED. 1 EXTERIOR ANTIOXIDANT,;DINT COMPOUND TO BE JSED CN ALL EXTERIOR CONNECTIONS. 1505 WESTLAKE AVENUE NORTH,SUITE 800 CR 2. EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONVECTIONS. 2. GROUND BAR SHALL NOT BE ISOLATED FROM TOWER.MOUNT DIRECTLY TO TOWER STEEL(TOWER ONLY). CONDNC SEATTLE,WA 98109 3, GROUND CAR SHALL NOT BE ISOUTD FROM TOWER.MOUNT DIRECTLY TO TOWER STEEL. 3. GROUND BAR SHALL BE ISO'LAT ED FROM BUILDING DR SHELTER. CONDUCTOR GROUND WAR ANTENNA GROUND BAR DETAIL TOWER/SHELTER GROUND BAR DETAIL BURNDY TWO HOLE LUG W/ {TMP)(SEE CHART) II 4 O ,i/f.: LONG BARREL SCALE: NOT TO SCALE ®SCALE: NOT TO SCALE (SEE CHART) O IP BARE WIRE TO BE TREATED WITH .,. 0ND-O%AT BOTH ENDS P.MARSHALL&ASSOCIATES mom: STRANDED ALL GROUNDING LUST ARE TO BE (SEE CHART) INSTALLED PER MANUFACTURERS IITwo \,, SPT LAC.DNS.ALL HARDWARE 9STEUN 3/6-11x1"-AMPER NUTS, LOCK WASHERS SHALL BE STAINLESS RESISTANT BOLT STEEL O ALL: HARDWARE ARE TO BE U PT87 (ttP) BAR, GROUND BOLT,FLAT WASHER,GROUND #6 MTV. FROM ANTENNA BAR, GROUND LUG FLAT WASHER AND CABLE GROUND KIT INSULATORS NUT. SEE NOTE 2. (TYR) ° BU #: 874135 WALL BRACKET o ° O MECHANICAL LUG CONNECTION TIGARD NE 0 ° ° SCALE: NOT TO SCALE GROUND BAR ON SHELTER.ICE " „ ' , „ 0 1 D955 SW 65TH AVE BRIDGE,OR ON ANTENNA TOWER o ° o TIGARD, OR 97223 1 0 ° CCU 1000OO ,OO °1OSEWEEOOAPER° O cal U O.O O 0, o GROUND BAR(4"x20") STAINLESS STEEL BOLT O O O ®'® O O 7 ice/ ,,J LOCK WASHER P/N M10 (TYP) Imi, --- (TYP) STARLESS STEEL REV DATE DESCRIPTION TWO-HOLE FLAT WASHER TWO ROLE LUG, OR EXOTHERMIC GROUNDING SHALL BE ELIMINATED COMPRESSION LUG 2-HOLE CRIMP/ (TYP) A 3/4/20 PRELIMS ____ WELD TO BE USED WITH#2 BARE WHEN GROUND BAR IS COMPRESSION CONNECTOR CONDUCTOR WIRE Tc BULL)NG ELECTRICALLY BONDED TO METAL 0 3/18/20 FOR CONSTRUCTION SERVICE GROUND OR GROUND HNG TOWER NOTES Ir--- GROUND 1. DOWN LEAD(HOME RUN)CONDUCTORS ARE NQT TO 3E INSTA_LED ON CROWN CASTLE USA INC. BAR TOWER,PER THE GROUNDING DOWN CONDUCTOR POLIO OAS-STD-10091.NO MODIFICATION OR DRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM CR FASHION, CAD-WELDING ON THE TOWER AND/OR IN THE STAINLESS STEEL -- ---- AIR ARE NOT PERMITTED. FLAT WASHER 2. EMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PUTCRM STEEL STAINLESS STEEL (TYP) ----- USE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS. BELLVILLE (PeP) STAINLESS STEEL NUT (TYP) SINGLE CONNECTOR AT GROUND BARS GROUNDWIRE INSTALLATION GROUND BAR DETAIL STAINLESS STEEL BOLT 4 SCALE: NOT TO SCALE 5 SCALE: NOT TO SCALE STAINT ESS STEEL RAT WASHER V \ DRAGON TOOTH WASHER 1 (TYR) : STEEL \i 2-HOLE CRIMP/ COMPRESSION STAINLESS STEEL WEATHERPROOFING KR CONNECTOR FLAT WASHER • tw..-,-,) (SEE NOTE 3) (1W) 120 Hu NOTE MINIMUM OF STA NLESS STEEL STAINLESS STEEL NUT COAX JUMPER : ANTENNA CABLES/S NUT 3 THREADS TOIBBE (TYP) BELLVILLE WASHER (TYP) MIN DESIGNED:EBG a� -I:��ids To ANTENNA (TAP) SINGLE CONNECTOR AT STEEL OBJECTS r� S/S SPLIT DRAWN: EBG WASHER CHECKED: PWM CABLE 2 HOLE LONG (TYP) CONNECTOR BARREL TINNED STAINLESS STEEL SOLID COPPER SELF-DRILLING STAINLESS STEEL WEATHERPROOFING KIT LUG S/S FLAT METAL SCREW FLAT WASHER Q,� JOB , $6 STRANDED COPPER GROUND (SEE NOTE 3) (TYP) _— WASHER (TYR) 019) "NO WIRE (TN) EXPIRES 6/ED/2(120 2OACCATMO6-0034 (GROUND TO GROUND BAR)SEE CABLE GROUND KT 2-HOLE CRIMP NOTES 1 &2 - COMPRESSION - TIN COATED SOLID CONNECTOR COPPER BUS BAR S/S FLAT NOTES: METALLIC OBJECT 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO CHERRY INSULATOR (DYE)ER DRAGON TOOTH WASHER GROUNDING GROUND BAR. INSTALLED IF REQUIRED S/S BOLT SINGLE CONNECTOR AT METALLIC STEEL OBJECTS DETAILS 2. GROUNDING KIT SHA'_L 3E TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BY CABLE (TYP) MANUFACTURER. 3. WEATHER PROOFING SHALL BE TWO-PART TAPE KIT,COLD SHRINK SHALL NOT BE USED. O SCALE: NOTT TO SCALEONNECTION ®SCALED NOT TO SCALE ®SCALE:NOTDTO SCALE EXTERIOR CONNECTIONS G.^ Sector A Ant Pos 1 Ant Pos 2 Ant Pos 4 80010066 NNHH-65C-R4 EPBQ-654L81-18-L2 _ IHNINI iliiiiin iiiiiiIiiini .... ....., RET 90( S AWS 90 1C1 s c. 700 850 850 850 5 700 700 700 70) VC �UU 9i "1 Al1'S:il r A�� mw ne oe .no. 1.,M114 114014 n.w lvrm ,xim �m .,,.� ,.� mm ,z.a. wmi 1.-..-, .o.n ,..... m.� .n.a. ,=r.m nm• RRH2x40.07LAT B25 RRH4X30.4R AirScale RRH 4T4R B5 1601^1 Fl RRH 4T4R B14 160W F'.: RRH4x25-WCS 1R B66A RRH4X45-4R AHCA p(1n) (1900) (A50) (7(10) (WCS) (AWS) 1II Optic > `Fth r --Cott'FiberI ti ---mantic Fiber I Ontir Fibet(nut „„1_Ontic Fib., Optic Fibe: Hatch Plate 1 Optic Fiber nnnnnnnnnnn DC Demarcation LJ L- Fiber Trunk Fiber Trunk 11111 Baseband U _:1d ,. Power Plant IORL002991 - :` iN001>" ''.' Sector B 1 Ant Pos 1 Ant Pos 2 Ant Pos 4 JAHH-65C-R313-V3 NNHH-65C-R4 EPBQ-654L8H8-L2 . HININHIN HINHOHNI X XiCiti< >< >< X >< >< i< X x x x x x x x x x h x x . RLT — ] 1 3 4 5�' g - g I r ; 4.. 5— ��... 7 N 1 .211 .111[ 4 9 tir T ..: ll_t3® f qtF 911LI 1000 � Is 901 C 700 90 5(� ft50 gyp OiU 85 700 700 700 70i 700 '� �. 1 111 MV .« rk,, � 1 Tu.. rsteed vanto ',Inate malt. n1.1 Istas, rt,tr, twou n.. 1,..., T.. Tula. RRH2x40-07L-AT B25 RRH4X30-4R AirScale RR H4TT4R B5 160W FI--.RRH 4T4R 014 160W F•0 RRH4s¢5-WCS-4R B66A RRH4X45-4R CA (700) (900) 13501 (700) (WCS) (AWS) _I . i i i III (c Fiber ...... ........ , 111 I P optic - —="-1')nlic F.ib= f. T ok= a I n P hr� l •.: •pnc Fibei M n NIB MO O Hatch Plate CO N O O 1 Optic Fiber :1-7W. Fiber Trunk Fiber Trunk ill 11111. and Unit Power Plant N0002991 Sector C Ant Pos 1 Ant Pos 2 Ant Pos 4 JAHH-65C-R3B-V3 NNHH-65C.R4 EPBQ-654L8H8-L2 . 111111111r1 x xxxx oe X % x x x x x x x x x x x xX% % x X X x X X % % x % % X x x x x X x X X x X x X X x x x X x x x x x % % x I 1111 HET REI- 1ow !i 3es ior 5 t, • 1 l S 5O (I= 7= 9� L T 3 4 14 ] 7 ,.,..,,‘ 1t 1_i 900 1900 . 5 AVF'S 901 C VC I 700 901 05 850 850 850 85, 700 700 700 70r • 00 J•j AW W tWS RRH2x40-07L-AT B25 RRH4X30-4R 'rScale RRH 4T4R R5 160 FI-xi RRH 4T4R B14 160W F"B RRH4x25-WCS-1R B66A RRH4X45-4R AHCA 1�S 4700) (1900) (850) (700) (WCS) 4AWS) 1 t r , 1 Ir I Optic Pie^� rFiller , ' . • I I vuu�riue) � u„) , rLl(:FIbP.i- 6 ' avairinars✓I r Fi -ipbG Fiber b I Fiber Iemarcation (D Squid) r.. La N. f] MINI In O 3 Hatch Plate 3 4-4 3.3 03 1 P 1 Optic Fiber MN Fiber Trunk Fiber Trunk II :..seband- Baseband Unit Power Plant (ORL002 UMTS 40RON000299) '..