Report ?CCS' sui thed?/k'612. z'ZUZO a0/86 • FB4C LEGACY LINE, FAN COIL B ryant SIZES 018 THRU 060 Product Data RECtiVCA MAR 3 0 2020 CITY OF 7+GA RD BUILDING DIVISION AIR HANDLER TECHNOLOGY AT ITS FINEST The FB4C fan coil has the proven technology of Bryant fan coil units with Puron® refrigerant as well as vertical and horizontal applications. The design features contoured condensate pans with rugged drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life, features homeowners appreciate. Standard features include grooved tubing and louvered fins. Coil circuiting has also been updated to make the most of all Bryant heat pumps and air conditioners. Units come with solid state fan controls, 1-inch (25mm) thick insulation with R-value of 4.2, multi-speed motors, and fully-wettable coils. Units can accommodate factory- and/or field-installed heaters from 3 to 30 kW. It also should be noted that the unique cabinet design of these fan coils meet stringent regulations for cabinet air leakage - a requirement of 2%cabinet leakage rate when tested at 1.0 inches of static pressure. • The FB4C fan coil design is loaded with popular features.These 0 • fan coils utilize the latest in electronic commutation motor(ECM) technology through the use of high efficiency, multi-tap ECM 1 motors allowing reliable air delivery with increased static pressure. It comes in a pre-painted(taupe metallic)galvanized steel casing and a factory-supplied power plug for ease of installation. The FB4C unit is shipped with a factory-installed Teflon-ring piston FB4CNF(018-048) or a Puron refrigerant TXV FB4CNF060, A10083 FB4CNP(018-060). STANDARD FEATURES • Multi-tap ECM(electronic commutating motor)motors-all sizes • Integrated motor controls,with 90-sec off TDR function,have replaced integrated circuit board • Five available speed tags to meet a wide range of applications • Large,grooved tube,louvered fin coils • Efficient,quiet,time-tested blower housings and diffusers • Sturdy,drainable condensate pans • Cabinet construction features innovations designed to prevent cabinet sweating • Tested for condensate disposal in much tougher conditions than Air Conditioning and Refrigeration Institute requirements • Super-thick R-4.2 insulation with vapor barrier • Pre-painted galvanized steel cabinet(taupe metallic) • Cabinet design meets stringent regulations for 2%cabinet leakage rate when tested at 1.0 inches static pressure • Installation-flexible,multipoise units • Horizontal hanging provisions on cabinet • No tools required to access filter • Newly improved filter rack area filter door insulation added for improved air seal • Factory-installed heater packages available on select models(5-through 15-kW) • 3-through 30-kW accessory heaters-field installed • Factory-supplied power plug • Easy plug-in provisions for heater installation • Entry options for high and low voltage wiring hook-up • Leak-preventing sweat connections • Puron refrigeration factory-installed Teflon-ring pistons on all FB4CNF(018-048)coils • Thermostatic expansion valve,TXV,on all FB4CNP coils and FB4CNF060 • Designed for manufactured housing applications. ADDITIONAL FEATURES • Factory-installed heater packages available on select models 2 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 F B 4 CNF 0 1 8 0 0 0 Product Heating Size F= Fan Coil 00 = No Heat 05 = 5 kW 7Ype 75 = 7.5 kW B= Base,Puron 08 = 8 kW 10= 10 kW Position 11 = 11 kW 4 = Muhipoise 15= 15 kW Coil Type Series 0= Copper C T=Tin—plate L=Aluminum Electrical N = 208/230v, 1 ph,80 Hz Capacity 018= 18,000 Cabinet Style 024 = 24,000 F = Single Piece with piston (TXV on FB4CNF060) 030= 30,000 P = TXV 036= 36,000 042 = 42,000 048= 48,000 060= 60,000 A PP .-... i CERTIFIED ® tare of me RHRI Codified TA indicates a aa+ Puron _ c us N▪m111k go for Individual U ,°.,weehne°T«wn«c. ISO 9001 QMISAIGbM0 DURATECH 3 IIWf SFR ILS ELECTRICAL A B C D E F G N J mAr 6mny SHIPPING XT SHIPPING WI , CHARACTERS TICS SLOPE 'A' NON 11 XCOAffO iIXCOA LED 1 fB/C XF 118 B,C • 42 11/16' 11 5/16' 12 7/16' 12 5/16' 11 1116' 18 1/8' 18 5/8' f2' A 112 11t IB/C XF 12I R,C 42 11/il' 11 5/16' 12 i116' 12 5/16' 11 1116' 18 118' IA 5/8' 12' A 112 112 1BIC NFUI B,C _ • /9 5/8' 11 5!8' IS 311' IS 5/B' IS 31 B' it 1l8' 23 SIBS • li' A • 122 122 Pli PB/CNF836 B.0 • 19 516' 11 SIBS IS 31 A' IS SIBS IS 318' 2J 1/8' 2J SIB• • IT' I - 122 122 FB IC NFUI B.0 •• 19 5/8' 8 I/8' 19 LP 19 1/8' 15 111E 6' 23 1I16' 23 1l8' -- Y 15i 151 iB ICNF118 B.0 q SIB' 21 1!8' 19 1/1' 19 118' 15 11116' 21 1116' 21 118' [ 151 151 a • • FBICNF80 B.C.O 53 MR' 21 1/0' 19 1//' 19 I/8' 19 fa' 27 111' 26 15/16' - - - A 175 175 s 7/8', 1 3/32' A=1F3 3 2'DIA N.0.'S _ FOR NIGH VOLTAGE 0=110 POWER WIRING -• •=1E5, DUE TO AVAILABLE FIELD 7/6'DIA. N.O. - INSTALLED HEATERS. a. 1 7!6' FOR LOW VOLTAGE ,, 523 2 r'` CONTROL WIRING 5 ■ `�-A g Uhl1 15116' ri ' NOTE NOTE: ALLOW 21' FROM FRONT W 8 g 1 318' 1. SERIES DESIGNATION IS THE 1/111 POSITION FOR SERVICE TOP VIEW Of 01111 PRODUCT NUMBER m m 22 1/16• 2. ALL DIMENSIONS ARE IN 'INCHES' UNLESS NOTED. II 3016' II' 7/9' GR *1 15/16'-.7 C-51 2 1/8' 1 OU TLFL AIR 3l1• �� D1.1 ISCONNECT OR �T Uy a L.I 1-+ CIRCUIT BREAAER ly a x V Y LOCATION `ALTERNATE y UNIT CONNECTION SIZES THB',1 3/12',2'DIA, N.O.•5 °fig ycyy IN -LOWER,CONTROL. FOR NIGH VOLTAG[ NITS MODULAR HAVE N•xl �• I ELECTRIC HEATER SUCTION. /18 6 124 • 5/8' I.D. SWEAT ALTERNATE POWER WIRING AN ISO-PIECEHAVE DN \►\►\Mwww3JJ111 A ACCESS PANEL 631 6 136 - ILA' I.D. SWEAT 7/6'DIA. N.O. OPPOSITE SIDE 3)6 y (1 112 TNRU 060- 118' 1.0. SWEAT FOR LOS VOLTAGE CABINET /y Z LIQUID: 3/8' I.D. SWEAT CONTROL WIRING = z CONDENSATE: 311'FPT e OPTIONAL FIELD CONVERTED _a ? 1� Y ISLOPEIGHT SIDE COILRUY1It5 ONU Y N LNG Nth. m O NLET AIR y 7CA ' PANELM OIL ACCESS A 1 10' a 93atle s L.• =� c MAO M11 I16' _ _ _ J �_ o S 2 5/8' o a ?4 • 2-„, • LIQUID LINE • E ■! ° z so:W iTTIXG IOUID LINE CONNECTION111 LIQUID LINE • ! o f^mod J M PANEL I 3 1/16' CONNECTION CONNECTION EI �R Eyy h SUCTION LINE CONNECTION • e Ymx 6 �R • ♦Ri II ` 19' NAfI MODULA gmE RRUNITS g gin SUCTION LINE i 11 7/16' ® `, , 11 3/I' CONNECTION . o' z w a N • 91/O'; IIIIlY • 1 III' � e5i • /T�� 6 3116' �.aiLli9 '� • • 11 'R �`i >tu 1� •- • • . c 3 �1 FILTER ACCESS OPENING PANEL 1 1fl'-�1 19 13I16' II OPENING ACCESS PANEL CONEIG FOB 2 112' 1, D ,1 SLOPE COIL DETAILS SLOPE COILS RIGHT SIDE VIEW CONNECTION LOCATIONS E.OWM DOWNFLON OR HOAR. FOR UPFLGIY OR NORM. RIGHT APPLICATIONS o J �NL Ei A[R LEFT APPLICATIONS AND INLET AI� J. v FRONT VIEW "A" COILS DOWNFIOW APPLICATIONS = 0 N SHOWN WITH'A'COIL DETAILS CONNECTION LOCATIONS FOR UPFLOW OR NORI2. APPLICATIONS MEASUREMENT- ENGLISH '" soee9e a m NA •"e 2 I E s N 4 • IMR SERIFS 11 Ef TALC A'' A B I C D E F G M J NON,ORATION SHIPPING W' C NAAAC i CRSf ICE SLOPE 'A' ILBSI (1113NP0161 A 4 ' I 12 11/16' 14 5/16" 12 1 I6 12 5,16' 10 1116' 18 1/8 18 5,1' '2 A 112 (BdCNP O2 dL A A • 42 II/I6' 11 5/16' 12 11I 6' 12 5116' 10 1116' 18 110" 18 518' - '2' 4 - Ill e (B40NP0301 A A • 49 5/8' 17 5/5" 15 3l1' 15 5/8" 15 318" 23 118' 23 518' - '1" A - Tit (B4CXP0361. A 4 • 49 5/8' 17 5/8' 15 3/4' 15 SIB' 15 PPE' 23 I/0' 23 5/4' - 'l' A - 122 - ___- FB4CNP012L A 4 • 49 5/0' 2 1l8' 19 III' 19 I/8' IS 11116" 23 1/IS" 13 1/8' - - 4 157 I (BICXPOIBI A I • 49 5,8' 21 1,8' 19 14' 19 1/8" 15 11/IP 13 7/16' 13 118" I 157 R AACNP 060t D 4 53 7/16' 2+ III' 19 1/6' 19 1 F8' 19 112" 27 111' 26 15r16' - - - A 115 '.. T-I/B I 3/32' 2' DIA. X.O.'S _ ,,, A-YES FOR HIGH VOL'ACE 07/10 POWER xl RIX4 471E5, DUE TO AVAILABLE FIELD INSTALLED N424, 1/8"DIA. R.O. [xS IAL LED HEATERS _ ./8-_, (0R LON VOLTAGE $ ti 57. CONTROL WIRING TW __ -..-I--1 I5/16' —El. MOTE: NWT' ALLOW 22 SE NVIC FROM FRONT Si 1 3l8' I SERIES DESIGNATION IS THE 141N POSITION TOP TOP 'VIEW OF UNIT PRODUCT/TABER 2P t/16' I t t'�— 2. ALL DIMENSIONS ARE IN 'INCHES' UNLESS NOTED. 10 3/16' II" 7/8' -B C .II L127R .1 (C 1 1' 1 v•L� i_a E�7 D ISCOx NECI OR 6 R_. N CIRCUIT 5REAXER yr. F LOCATION "\-ALIERNATE y UNIT CONNECTION SIZES n0'n Lu',2°DIA. rc.0.'S 6eD �I �J BLOWER. CONTROL. FOR 1IGH VOLTAGE hOiE' MOGUL AR C[I III d ELECTRIC HEATER SUCTION' 018 1 021 5/B' I SWEAT AL i ER XA1E� POxEP WIRING A TWO WILL',AVE 9 ACCESS PANEL 030 6 Ol6 -J/4' ].p SWEAT A II*PIECE _ 118'D1A n.0 OPPOS1lL SIDE O n 042 THRU 060 - 7/8' I.O. SWEA' FOR LOVE VOLTAGE WINE TOWD. 3/8' 1_D. SWEAT [OMIAOL WIRING CONDENSATE' 3l1' F8i OPTIONAL FIELD CONVERTED Z LA RIGHT SIDE RETURN OPENING yWW 6 ISLOPE COIL UNITS OSl O, LNL Er AIR A CA OIL ACCESS l—•• r_' 1/2" e — ANEL n r' % s/8. ITT/16' i , 4 P�'P (ITrINcLIOUID LINE ° E : {{{111 I ° si', ,c A ° L10UID LINE CONNECTION ill CONNECTION lIOU[0 LI NF ° A :1:12: 111.,: PANtI J 111 fi" CONNECTION dl_(. Wg II. S.CTIOX LINE CONNEC-ION • I I �— i� 1 3.16 Mu H g � s • �/ �¢ I FOR• 19' NO-DULAR UNITS •suc SUCTION LINE �• dil 10 IA l CONNECTION IP ° 0 I =.- _ f 'o O•) 6 31,6" 9 112' .; r ° o .' 10 ° .. i JId' L $fie E O—GPENING��•: 6 I I � . • • .r I 1 FIER ACCESSOPENING SLOPE COIL DETAILS P. D ACCESS PANEL CONFIC FOR 1 1/P fk 19 13/16` 2 1/2 SLOPE COILS RIGHT SIDE VIEW CONNECTION iI pN LOCATIONS SHOWN OOWNR Ox OR HORIt s■t LFOR MIN OR NDR:Z. RIGHT APPLICATIONS ��� c X.Ei AIR LEFT APPLICATIONS ANOLE1 AIR �' FRONT VIEW "A' COILS _ ,�y Ro SHOWN WITH TA' COIL DE1AIt5 CONNECTION DCWN/LOW APPLICATIONS 38E/ LOCATIONS FOR UPFLOW OR HOAR. APPLICATIONS W MEASUREMENT- ENGLISH ' sos206 A so gr. •,� r i NOTES: SLOPE C011 I.CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. 2. ALL DIMENSIONS ARE IN'INCHES' UNLESS NOTED. o 1/16' TOP. AIRFLOR 12 PLACID. AIRFLDW' l 2 3/IS'TIP. - tt PL A[[Sb 11 + Y © T ZI• TYP. 1 PRIMARY DRAT (2 PLACES!. 3 1/1' SECONDARY DRAT F G PRIMARY DRAT III SECONDARY DRAY gi PRIMARY DRAT 113116' r. SECONDARY DRAI TYP.• i IYP.. C I SECONDARY DRAIN FrI S• 8 _ PRIINRY GRAIN H tPb; I' 2 ?IV m illW 6' L 3.•:4.:_i 5l a' _ Egli s b I12' YIP I' irr.TU/PLACES In• !.- 4 TYP,• 5/9' 2 9116" 12 PLACES). 2 118' 1 I11' TOP.• 11 ]l8' i LI May 'P!Sy57S 1/8. 2 118' 2 3TYP• 3 111. ITYP6• F TYP.• fey ly J IYP.• (2 PLACES). DOWNFLOW , -HORIZ. LEFT s UPFLOW (FIELD CONVERTED) HORIZ. RIGHT 01 e (AS SHIPPED) (AS SHIPPED) (FIELD CONVERTED) _ — a G �J v OI m AA • HORIZONTAL MOUNT LOCATIONS . DIMPLES PROVIDED IN TOP PANEL. AIRFLOW 1116'TYP. 11 PLACES/ESI AIRFLOW IF AND BACK SF CABINET. IN CABINET HORROR. HOLES PROVIDED _ n r 2 3TYP' TOP, CA n .136' DIA. HORIZONTAL HANGING HARDWARE TO DE FIELD SUPPLIED. t I t2 PLACES). :2 '/ w 1 0 Eek N O I'T . - ¢ _ ., L © -CTIT.12 PLACES! 1 TaA T. = SECONDARY DRAI F 1 3/1' ' G o g`-ST1 22 a �"+ TO PRIMARY DRAI 3 I/16'T 1 SECONDARY DRAIN PRIMARY DRAIN z *oVeR c 8e PRIMARY DRAY 13f 16' O . •. kae* S/16' TYP• 1 ECONDART DRAIN `o W`ai_SECONDARY DRAI R iY A _ .. 4.. 1 — `21 1 , ,_ PRIMARY DRA IX� e>s:3 L iM ,._ . • 112' I Ili'l 1• • 5/16' �, 3 Il l6' it l6' iI P,-�{I�-� 5 118' Tl l6' If2' TYP• ] 5 OAR' 2 II/16' I ' I TYP• 11 PLACES]. .1 1/8' lla• 3TYP' 2 3TYP' 1 311' 113/16' IYP.• s N • TIP. 1 718• 12 PLACES!. DOWNFLOW TAP. HORIZ. RIGHT TOP]• II �' HORIZ. LEFT UPFLOW (FIELD CONVERTED! (FIELD CONVERTED) (AS SHIPPED) (AS SHIPPED) = CO s o A COI L MEASUREMENT- ENG ^^ 25158-/ 7 7 ..' 1 2 A D 1 Lou SHIPPING VT SHIPPINGIy� W1 TAINT SERIES ELECiRICAI A 8 C 0 E F G N 3 S OPE AA•IID•X NON iiM9•COAIED iiN LDA1II0 [NARAC IE RStI[S F BICNF tlB B,C % • 1184.3 383.6 315.1 312.8 265.1 461.4 473.1 314.8 N - 51.8 50.8 • F34CN5121 8,C % I 1684.3 363.E 315.9 312.8 265.1 411.4 473.1 - 314.8 X • 51.8 50.8lj Illill FUCKS). 8.0 X • 1261.5 447.7 411J 391-9 391.5 587.4 611.1 - 431.8 N • 55.3 55.3 ffi FBHCNF136 8,C X • 1t61.5 111.1 111.1 396.9 191.5 557.1 6H.1 431.8 N 55.3 55.3 f00018112 B.0 % • 1261.5 536.E 489.1 185.8 398.5 595.3 581.1 X 71.2 71.2 FB/CNF118 B.0 % • 1261.5 536.E /89.1 /85.8 398.5 595.3 581.1 X 71.2 77.2 _, • • FBICNF661 B,C,D % I 1357.3 536.6 489.I 485.8 495.3 612.2 681.2 - - - X 79.4 79.4 X 22.23, 27.18 Y 51.81 DIA. N.O.'S 0:YES F0A NIGH VOLTAGE 0:N0 POWER WIRING ..YES. DUE TO AVAILABLE FIELD 22.23 DIA. A.D. Ol O INSTALLED HEATERS. Z.; 41.6 FOR LO1 VOLTAGE ,., ,V CONTROL WIRING y_ ill19.2 -1 25.1 NOTE. NOTE. ALLOW 555.4 FROM FRONT W'p' S I 54.9 1. SERIES DESIGNATION IS THE IITH POSITION FOR SERVICE .Y t V TOP VIEW OF UNIT PRODUCT NUMBER - m m s 561.1 I �7I 2. ALL DIMENSIONS ARE IN'OM' UNLESS NOTED. 258.8 219 1 22 2 a 23.8-+7 �-C------------, 51.1 r-25.1 OUTL ET AIA 1 {19.1 aga I�1 W :I SCSNNECT OR / a�b A CIRCUIT BRENNER Y: e`s" 1 LOCATION ALTERNATE N g Z UNIT CONNECTION SIZES 22.23. 21.10. 53.81 DIA. %.0.'S hgy LOSER, CONTROL. FOR HIGH VOLTAGE NOTE NODULAR gy te 6 ELECTRIC HEATER SUCTION: 118 1 624 - 15.88 I.D. SWEAT ALTERNATE POWER WIRING UNITS BILL HAVE �� ACCESS PANEL 131 d 036 19.15 1.0. SWEAT EAT 22.23 DIA X.O. OPPOSITEWIRING LNG •IE O A 142 THRU 166• 22.23 I.D. SWEAT FOR LOW VOLTAGE CABINET IECE M _ n LIgl10: 9.53 I.O. SWAT CONTROL WIRING - m •Y, CONDENSATE, 18,1 FPT OPTIONAL FIELD CONVERTED .N. < Z "V RIGHT SIDE RETURN OPENING =y 5 m 1 INLET AIR (SLOPE COIL UNITS ONlfl GO OIL ACCESS A o Ode z ^ ' PAMCL _, 1111111111111111.1; __-_-___ _ 3B.1 Q 0. Q O n 66.7 119.1 •• III _• E 1y1w•. _ e !w1 PANEL '• IOUID LINE CONNECTION ll 8 ONNED LONE • e Cp11O1MCCIIOA E n I , o 2:E d w CONNECTION I °J ee -p III SUCTION LINE CONNECTION • . ., C5 sp6 �y _ 31.2�{ I M,J1A H e gybe _ (s. ° .., I¢ I FOR = AZGOR 482.6 NOOULAA UNITS E 265.1 ' SUCTION LINE‘w 0 I W e h��� 233.1 CONNECTION 2n 3 Y Y u.l a -= i' ,,,,, in, ,5 .2 i a • 127.0 FILTER ACCESS OPENING I )1 OPENING PANEL •• ACCESS PANEL CONFIG wR 31.8--.1 'A 513.2 `'I -63.5 1 8 25.1 D SLOPE COIL DETAILS SLOPE COILS RIGHT SIDE VIEW !/ CONNECTION LOCATIONS SH0/N DOWNFLOU OR xOLS FORLEFT APPLICLOW ATIONS NOR IE. RIGHT APPLICATIONS u I INLET AIR AP PLI[AT IONS AND INLE1 AIA FRONT VIEW 'A" COILS 0 ' SHOWN WITH'A'COIL DETAILS CONNECTION p01FNFlOW APPLICATIONS �/ LOCATIONS FOR UPFEOW OR HURI2. APPLICATIONS MEASUREMENT- METRIC "sr '"' S3489e-1 I" "• •a m, 1 3 E 70 N 8 ELECIDIUL PoWrI5YAU19A SHIPPING WI IIR SERIFS CR680011801IDS A 8 C D C r 6 H 3 SLOPE .AT L X9+1 F64C6IP0I8L 9 A '094,3 363.6 315.9 312.3 265.1 460.4 413.1 - 304.8 i - 50.8 E44C1112024L I • '084.) 363.6 315.3 312.6 265.1 460.4 433.1 - 304-6 1 - 50,8 FB4C11P030L A • 1260.5 447.7 400.0 396.9 390.5 581.A 600.7 - 431.8 I - 55.1 e FB4CN1,036L I • '260.5 447 1 400.0 396.9 110.5 ' 581.e 600.1 431.8 9 - 55.3 1B406P042L I 9 6 '260,5 536.6 489.0 485.8 398 5 595 3 581 a - - - 9 11.1 F44CNP038.1 A 6 1260.5 536.6 489.0 485.8 398.5 595.3 581.4 - - • I 11.2 2 ai • ° FB6NP06C.I U A •• I 1353.3 536.6 489.0 485.8 435.3 692.2 684.2 - - - 9 19.4 /r22 23 2r 16 50,60 DIA. e.O.'5I _ I VIES TOR HIGH vOLTAGE OLEO °OWEN WIRING .,YES. DUE 10 AVAILABLE FIELD 22.23 DIA XAG l INSTALLED HEATERS. 4L6 / FOR ROL VOLTAGE ,,, y 4\�CTry]/F CONTROL WIRING _ 49,2 -1 25 4 NOTE: SERIES OC SSG XNT ION IS THE 141H POSI'ION NOTE' FOR OSERVICE 3.. IRON FRONT I:tl LE V TOP VIEW 34,9 Or UNIT PRODUCT NUMBER W,�m m 2 ALL DIMENSIONS AWE IN'AM'UNLESS NOTED. 8 r 560�258.8 4 219.4 -22.2 _8 23.8 C 51 0- --25.4 OUIl ET AIR -I3.0 e,y LLE���11I -DISCONNECT OR } V °; S N CIRCUIT BREPXfR 1 Wy\.JW LOCATION -AL iE Ap4TC L UNIT CONNECTION SIZES 2223 21.16. 50.80 DIA. N.C.'s hg4 'LOWER, CON t NOL NOTE: MODULAR 9• 6 ELECTRIC HEATER SUMO: 018 4 024 - 15.48 I.U. SWEAT -OR HIGH VOLTAGE 8CA - Ac([53 PANEL 030 4 036 19.05 I.D SWEAT UNITS WIE HAVE I ii" ALTERNATE °OWER WIRING n 2t.23 D1A SO, OPPOSITE 510E 053 1HRU SWEAT -2223 LD. SWEA, A TWO'PIECE � l"DUID 9 SJ I.D. BNEAT FOR '.RR VOLTAGE CABINET Z CONDENSATE: 19.0 EP1 CONTROL WIRING r- / o ii CC b 1 RIGHT 514E RETURONAL FIELD N OPENING ' ' INE AIR y 'SLOPE CO:L OTS ONUI 85 / OIL ACCESS A /� ]d.f PANEL � a !CC iffloommet . O n 66.1 119.E 1 1131 •• • °� FITTING 1° LWNID LINE CONNECTION ° LIOU IG LINE •° 110UID l]XE ° ° ° 'a=Wa v° V '`nil �PnREL 1L8 /CONNECTION CON NCG ION / V Sex SUCTION LINE CONNECTION d_1 V k;1.; �p89A� i - [. 30 2-1,- vNg H o -6 _ �5,2� = _sue"., " lR ° • '" • ,z 482.6- - A9 MCO G>AP RUNT iS E =g - ..y. 265.1 SUCTION LINE I >: `S. 2 0,0 CONNECTION ° ° c c„" o 2e'.1 .411 • a I.Y1 0 44.4 o Bi?_S • f'ti 0 i11TER ACCESS PANEL OPENING OPENING ACELS5 PANE CONFIG. FOR 21.8--1 I 503.2 zs e-- 0 SLOPE COIL DETAILS SLOPE COILS i63.5 CONNECTION LOCATIONS SHOWN RIGHT SIDE VIEW FOR UPI LOW OR RORI2. DOWNFL09 OR HORI2. INLET FIN? LEFT APfI ICA'IONS RIGHT AP PL IC AT IOAc AND IXL Er a1J a I F RON7 VIEW "A" COILS DDWxr109 APPLICATIONS Wo SHOWN WITH 'A'COIL DETAILS CONNECTION 100 LOCATIONS FOR UPIl0W OR HOW. APPLICATIONS Os MEASUREMENT- METRIC "Sr ""' SDS2I& 4 ,HI " Y A 1 V NOTES: SLOPE COI ) I.CONDENSATE PAN DRAIN CAPS NOT SHOWN FOR CLARITY. . 2 ALL DIMENSIONS ARE IN'MR' UNLESS NOTED. o II.1 TOP. AIRFLOWli PLACESI• AINFLON 55.6 TIP. 1 I r12 PLACESI• 1 + 2 © 25.1 IIP. PRIMARY DRAI 12 PLACES]. 82.6 SECONDARY DRAI F y+�. G PRIMARY DAAI el 31.8 'II SECONDARY DRAI F. PRIMARY DRAIN I6.0��II II�� 1 SECONDARY DRAIN i+P.• I �� YIP • •+ II SECONDARY DRAI , imixii © I I :i PAIMAR}DAAI� rr` © `� �� 1iJ.U/ , lL Qo I .. iesZ el 31.82 . 11 PI ACESb�::i:i rLi iTP.• 11.3 .I I2 PCf3Y• 51.0 iTP.• 22.2 a=e A 16,0v 3,8 IIP.• y1 n 22.2 13.0 55.TYP6 82.6 IIP.• F = l� Z TYP.• HORIZ. LEFT 127.0 12 PLACESI• UPFLOW DOWNFLOW agy 'z (AS SHIPPED) (AS SHIPPED) (FIELD CONVERTED) HORIZ, RIGHT ge - m (FIELD CONVERTED) !Q C1-1 0 a =y A:) CO • AMIDNORIZONIAL MOUNT LOCATIONS •DIMPLES PROVIDED IN TOP PANEL. AIAFLOI U PlAtE 31 AIRFLOW s4CI m VI A AND BACK OF CABINET. IN CANINE)BOTTOM. HOLES PROVIDED r 55.6 IIP. 3 n 3.45 DI A. HORIZONTAL HANGING HARDWARE 10 BE(ICED SUPPLIED, } 4 PL ACE31• e =„a *CI -I-25.4 TIP. A T o aa�a C 12 PLACES) - a I sY$ a q SECONDARY DRAI F 120 6 ••0 O• G _-mss 3 R PRIMARY DRAI co11.8- ♦ . SECONDARY DRAIN PRIMARY DRAIN $ IOC L PRIMARY DRAT TYP�• I•� O f I 8.D SECONDARY DRAIN a ?a - SECONDARY DRAIN I I TYP.• PRIMARY OAAIM� ` OQPeT 11O :�cJ © �o1ill �1 Ir-�I®•. p .O� OJ1�i1.1 •sI?2 PlACE31• �� 38.1 lyaY a I::: 38.1J 1 119.2 8.0 L*, iLB L Y ILI Ty 1/9.2 30.2 12.1� e. ti 30.2 TIP. 55.6 q0.6 68.3 t1 PIAC ES)• �20a.0 _ P.• 22.2 16.0 I+P• 200.0 C2 PLACED]. DOWNFLOW TM. HOR Z. RIGHT TOP., HORIZ. LEFT UPFLOW (FIELD CONVERTED) (FIELD CONVERTED) d / °; (AS SHIPPED) (AS SHIPPED) •' A-CO I L -' KV MEASUREMENT- METRIC 'Sr - S05I58-11 9I A ao, A a N to PHYSICAL DATA NOMINAL COOLING DIMENSIONS SHIPPING ORDERING NO. CAPACITY(Btuh) Height Width Depth WEIGHT FB4CN(F,P)018(0,T,L) 18,000 42-11/18 in. 14-5/16 in. 22-1/16 in. 112 lb 1084mm 363mm 560mm 51 kg FB4CN(F,P)024(0,T,L) P4,000 42-11/16 in. 14-5/16 in. 22-1/16 in. 112 lb 1084mm 363mm 560mm 51 kg FB4CN(F,P)030(0,T,L) 30,000 49-5/8 in. 17-5/8 in. 22-1/16 in. 122 lb 1260mm 447mm 560mm 55 kg FB4CN(F,P)036(0,T,L) 36,000 49-5/8 in. 17-5/B in. 22-1/16 in. 122 lb 1260mm 447mm 560mm 55 kg FB4CN(F,P)042(0,T,L) 42,000 49-5/8 in. 21-1/8 in. 22-1/16 in. 1571b 1260mm 536mm 560mm 71 kg FB4CN(F,P)046(0,T,L) 48,000 49-5/8 in. 21-1/8 in. 22-1/16 in. 157 lb 1260mm 536mm 560mm 71 kg FB4CN(F,P)060(0,T,L) 60,000 53-7/16 in. 21-1/8 in. 22-1/16 in. 1751b 1357mm 536mm 560mm 79 kg SPECIFICATIONS FB4C 18 24 30 38 42 48 80 EVAPORATOR COIL Face Area(sq.ft) 2.23 2.97 4.45 5.93 Configuration Slope A FB4CNF TXV Metering Device (Copper and (Teflon—ring piston) EA52PT052 F059PT057 EA52PT067 EA52PT070 EA52PT076 EA52PT080 Tin models Puron Refrigerant only) FB4CNP TXV Metering Device TXV TXV TXV TXV TXV TXV (Aluminum Puron Refrigerant models only) FILTER* 21-1/2—in 13—in 16-3/8—in 19-7/8—in (546 mm)X (330 mm) (417 mm) (505 mm) BLOWER ASSEMBLY Motor Type(ECM) Multi—tap ECM Motor HP 1/3 1/3 1/3 1/2 1/2 3/4 3/4 CFM 600 800 1000 1200 1400 1600 1750 *Fitter must be field—supplied for FB4C units. 10 PERFORMANCE DATA FB4C AIRFLOW PERFORMANCE (CFM) • MODEL&SIZE BLOWER SPEED 0.10 0.20 0.90 0.40 0.50 0.60 Tap 5 669 620 565 Tap 4 614 569 534 486 436 398 FB4C 018 Tap 3 860 818 581 537 499 Tap 2 614 569 534 486 436 398 Tap1 614 589 534 486 436 398 Tap 5 892 835 763 676 Tap 4 826 795 766 743 706 660 FB4C 024 Tap 3 826 795 766 743 706 660 Tap 2 701 660 616 581 537 499 Tap 1 617 592 552 507 472 420 Tap 5 1108 1090 1065 1034 1009 974 Tap 4 1026 1000 969 938 899 865 FB4C 030 Tap 3 1026 1000 969 938 899 865 Tap 2 909 873 842 799 762 724 Tap 1 825 795 757 722 674 634 Tap 5 1301 1276 1245 1218 1176 1121 Tap 4 1227 1191 1169 1143 1105 1074 FB4C 036 Tap 3 1227 1191 1169 1143 1105 1074 Tap 2 1087 1062 1030 1001 966 930 Tap 1 1026 1000 969 938 899 865 Tap 5 1560 1544 1507 1464 1424 1358 Tap 4 1419 1397 1358 1320 1279 1239 FB4C 042 Tap 3 1419 1397 1358 1320 1279 1239 Tap 2 1249 1220 1184 1142 1093 1052 Tap 1 1242 1205 1158 1110 1069 1026 Tap 5 1743 1712 1679 1642 1810 1574 Tap 4 1669 1634 1599 1564 1531 1499 FB4C 048 Tap 3 1669 1634 1599 1584 1531 1499 Tap 2 1452 1413 1377 1339 1308 1271 Tap 1 1300 1256 1221 1182 1142 1101 Tap 5 1897 1887 1836 1808 1774 1738 Tap 4 1817 1785 1757 1724 1693 1655 FB4C 060 Tap 3 1817 1785 1757 1724 1693 1655 Tap 2 1657 1621 1589 1557 1518 1474 Tap 1 1443 1412 1377 1332 1286 1243 —Airflow above 450 cfm/ton. NOTES: 1. Airflow based upon dry coil at 230v with factory—approved filter and electric heater(2 element heater sizes 018 through 036,3 element heater sizes 042 through 060).For FB4C models,airflow at 208 volts is approximately the same as 230 volts because the multi—tap ECM motor is a constant torque motor.The torque doesn't drop off at the speeds the motor operates. 2. To avoid potential for condensate blowing out of drain pan prior to making drain trap: Return static pressure must be less than 0.40 in.wc. Horizontal applications of 042—060 sizes must have supply static greater than 0.20 in.wc. 3. Airflow above 400 cfm/ton on 048-060 size could result in condensate blowing off coil or splashing out of drain pan. 11 PERFORMANCE DATA (cont.) GROSS COOLING CAPACITIES (MBH) - PURON® REFRIGERANT UNIT INDOOR COIL SATURATED TEMPERATURE LEAVING EVAPORATOR(°F/°C) SIZE AIR 35/2 40/4 45/7 50/10 55/13 CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF 72/22 41 20 0.00 37 17 0.00 32 15 0.00 27 13 0.02 21 11 0.03 525 67/19 33 20 0.03 29 18 0.03 24 18 0.03 19 13 0.03 13 11 0.04 62/17 26 20 0.03 22 18 0.03 18 16 0.04 14 14 0.10 11 11 0.26 FB4C 72/22 45 22 0.00 40 19 0.00 35 17 0.01 30 15 0.03 23 12 0.04 018 600 67/19 37 22 0.04 32 20 0.04 27 17 0.04 21 15 0.04 15 12 0.05 62/17 29 22 0.04 24 20 0.04 19 18 0.05 15 15 0.12 13 13 0.28 72/22 49 24 0.00 44 21 0.00 38 19 0.03 32 16 0.04 25 13 0.05 675 67/19 40 24 0.05 35 22 0.05 29 19 0.05 23 16 0.05 16 14 0.06 62/17 32 25 0.05 27 22 0.05 21 19 0.08 17 17 0.14 14 14 0.29 72/22 43 22 0.00 38 20 0.00 33 17 0.03 28 15 0.04 22 12 0.05 700 67/19 35 23 0.05 30 20 ' 0.05 25 18 0.05 20 15 0.05 14 13 0.06 62/17 28 23 0.06 23 21 0.06 18 18 0.06 15 15 0.14 12 12 0.29 FB4C 72/22 47 24 0.00 42 22 0.01 36 19 0.04 31 17 0.06 24 14 0.06 024 800 67/19 38 25 0.06 33 22 0.08 28 20 0.07 22 17 0.07 15 14 0.08 62/17 30 26 0.07 25 23 0.07 20 20 0.08 16 16 0.17 13 13 0.31 72/22 51 26 0.00 45 24 0.03 40 21 0.06 33 18 0.07 26 15 0.07 900 67/19 41 27 0.07 36 25 0.08 30 22 0.08 24 19 0.08 17 16 0.09 62/17 33 28 0.08 28 25 0.08 22 22 0.09 18 18 0.19 15 15 0.33 72/22 62 31 0.00 56 28 0.00 49 24 0.02 41 21 0.04 32 17 0.04 875 67/19 51 32 0.04 44 28 0.05 37 25 0.05 29 21 0.05 21 18 0.05 62/17 40 32 0.05 34 29 0.05 27 25 0.06 21 21 0.13 18 18 0.28 FB4C 72/22 68 34 0.00 61 31 0.00 53 27 0.04 45 23 0.05 35 19 0.06 030 1000 67/19 56 35 0.06 49 31 0.06 41 28 0.06 32 24 0.06 22 20 0.07 62/17 44 36 0.06 37 32 0.06 29 28 0.07 24 24 0.16 20 20 0.30 72/22 74 37 0.00 66 33 0.02 58 29 0.05 48 25 0.06 38 21 0.07 1125 67/19 60 38 0.07 53 34 0.07 44 30 0.07 35 26 0.07 24 22 0.08 62/17 48 39 0.07 40 35 0.07 32 31 0.09 26 26 0.18 21 21 0.32 72/22 68 34 0.00 61 31 0.00 53 27 0.04 45 23 0.05 35 20 0.06 1050 67/19 56 36 0.06 49 32 0.06 41 28 0.06 32 24 0.07 22 20 0.07 62/17 44 36 0.07 37 33 0.07 30 29 0.08 24 24 0.17 20 20 0.31 FB4C 72/22 75 38 0.00 67 34 0.03 58 30 0.06 49 26 0.07 38 22 0.07 036 1200 67/19 61 39 0.07 53 35 0.08 45 31 0.08 35 27 0.08 25 22 0.09 62/17 49 40 0.08 41 36 0.08 32 32 0.09 26 26 0.19 22 22 0.33 72/22 81 41 0.00 72 37 0.05 63 32 0.07 53 28 0.08 41 23 0.09 1350 67/19 66 43 0.08 58 38 0.09 48 34 0.09 38 29 0.09 27 25 0.10 62/17 53 44 0.09 44 40 0.09 35 35 0.11 29 29 0.22 24 24 0.35 72/22 89 44 0.00 80 40 0.00 70 35 0.02 58 30 0.03 46 25 0.04 1225 67/19 73 45 0.04 63 41 0.04 53 38 0.04 42 31 0.04 29 25 0.05 62/17 58 46 0.04 48 41 0.04 38 38 0.05 30 30 0.12 25 25 0.28 FB4C 72/22 98 49 0.00 88 44 0.00 77 39 0.03 64 33 0.04 50 28 0.05 042 1400 67/19 BO 50 0.05 70 45 0.05 58 39 0.05 46 34 0.05 32 28 0.06 62/17 64 51 0.06 53 46 0.06 42 40 0.06 34 34 0.14 28 28 0.29 72/22 106 53 0.00 95 48 0.00 83 42 0.04 69 36 0.05 54 30 0.06 1575 67/19 87 55 0.06 76 49 0.06 63 43 0.08 50 37 0.07 35 31 0.07 62/17 69 56 0.07 58 50 0.07 46 44 0.08 37 37 0.17 31 31 0.31 72/22 88 46 0.00 79 42 0.00 69 37 0.03 58 31 0.04 45 26 0.05 1400 67/19 72 48 0.05 63 43 0.05 52 37 0.05 41 32 0.05 29 27 0.06 82/17 57 49 0.06 48 43 0.06 38 38 0.06 30 30 0.14 25 25 0.29 FB4C 72/22 97 51 0.00 87 46 0.01 75 40 0.04 83 35 0.06 49 29 0.06 048 1600 67/19 79 52 0.06 69 47 0.06 57 41 0.07 45 36 0.07 32 30 0.08 82/17 63 54 0.07 53 48 0.07 42 42 0.08 34 34 0.17 28 28 0.31 72/22 105 55 0.00 94 50 0.03 82 44 0.06 68 38 0.07 54 31 0.07 1800 67/19 86 57 0.07 75 51 0.08 62 45 0.08 49 39 0.08 34 33 0.09 62/17 68 59 0.08 57 53 0.08 45 47 0.09 37 37 0.19 30 30 0.33 72/22 106 54 0.00 95 49 0.00 82 43 0.01 69 37 0.03 54 31 0.04 1600 67/19 86 56 0.04 75 50 0.04 63 44 0.04 49 37 0.04 35 31 0.05 62/17 68 56 0.04 57 50 0.04 45 44 0.05 36 36 0.12 29 29 0.28 FB4C 72/22 113 58 0.00 101 52 0.00 88 46 0.02 74 39 0.04 58 33 0.04 O60 1750 67/19 92 59 0.04 80 53 0.05 67 47 0.05 53 40 0.05 37 33 0.05 62/17 73 61 0.05 61 54 0.05 49 48 0.06 39 39 0.13 32 32 0.28 72/22 124 64 0.00 111 57 0.00 97 50 0.04 81 43 0.05 63 36 0.06 2000 67/19 101 66 0.06 88 59 0.06 74 52 0.06 58 44 0.06 41 37 0.07 62/17 80 67 0.06 67 60 0.06 53 53 0.07 43 43 0.16 35 35 0.30 CFM-Cubic Ft per Minute EWB-Entering Wet Bulb°F(°C) LWB-Leaving Wet Bulb°F(°C) TC-Gross Cooling Capacity 1000 Btuh SHC-Gross Sensible Capacity 1000 Btuh BF-Bypass Factor MBH-1000 Btuh 12 PERFORMANCE DATA (cont.) NOTES: SHC CORRECTION FACTOR 1. Contact manufacturer for cooling capacities at conditions ENTERING AIR DRY-BULB TEMPERATURE(°F) other than shown in table. 79 78 77 78 75 Under 75 2. Formulas: - Leaving db=entering db-sensible heat cap. BYPASS 81 82 83 84 85 Over 85 1.09 x CFM FACTOR ENTERING AIR DRY-BULB TEMPERATURE(°C) Leaving wb =wb corresponding to enthalpy of air leaving 26 25 25 24 24 Under 75 coil(hlwb) 27 28 28 29 29 Over 85 hlwb=hewb-total capacity(Btuh) Correction Factor 4.5 x CFM 0.10 .098 1.96 2.94 3.92 4.91 Use where hewb=enthalpy of air entering coil.Direct interpola- 0.20 0.87 1.74 2.62 3.49 4.36 - formula tion is permissible.Do not extrapolate. shown 0.30 0.76 1.53 2.29 3.05 3.82 below 3. SHC is based on 80°F(27°C)db temperature of air enter- Inte lation is rmissible. ing coil.Below 80°F(27°C)db,subtract(Correction Factor Correction Factor=1.09 x(1 - BF)x(db-80) x CFM)from SHC. Above 80°F(27°C)db, add (Correc- tion Factor x CFM)to SHC. 4. Bypass Factor=0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation. FB4C AIR DELIVERY PERFORMANCE CORRECTION COMPONENT PRESSURE DROP (in wc)AT INDICATED AIRFLOW (DRY TO WET COIL) CFM UNIT SIZE 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 018 024 -- 030 038 -- -- -- -- --042 -- 048 -- -- -- -- -- -- -- -- -- 0.063 0.070 0.076 0.083 0.090 -- -- 060 -- -- -- -- -- -- -- -- -- -- -- 0.049 0.054 0.059 0.065 0.070 ELECTRIC HEATER STATIC PRESSURE DROP(in wc) FB4C FB4C 018-038 042-060 HEATER EXTERNAL STATIC HEATER EXTERNAL STATIC ELEMENTS kW PRESSURE ELEMENTS kW PRESSURE CORRECTION CORRECTION 0 0 +.02 0 0 +.04 1 3,5 +.01 2 8,10 +.02 2 8,10 0 3 9,15 0 3 9, 15 -.02 4 20 -.02 4 20 -.04 6 18,24,30 -.10 The airflow performance data was developed using fan coils with 10-kW electric heaters(2 elements)in the 018 through 036 size units and 15-kW heaters(3 elements)in the 042 through 060 size units.For fan coils with heaters of a different number of elements,the external avail- able static at a given CFM from the curve may be corrected by adding or subtracting available external static pressure as indicated above. MINIMUM CFM AND MOTOR SPEED SELECTION FB4C HEATER kW 3 5 8 9 10 15 18 20 24 30 018 525 525 525 - 600 - - - - - 024 700 700 700 - 700 775 - - • - - 030 - 875 875 - 875 875 - 1060 - - 036 - 1050 970 970 970 920 - 1040 - - 042 1225 1225 1225 1225 1225 1225 - - 048 - - 1400 1400 1400 1400 1400 1400 1400 1400 060 - - 1750 1750 1750 1750 1750 1750 1750 1750 Speed Tap 4(white wire)is used for electric heat only.White wire must remain on tap 4. 13 PERFORMANCE DATA (cont.) FIELD-INSTALLED FILTER STATIC PRESSURE DROP(in wc) CFM FB4C 400 600 800 1000 1200 1400 1600 1800 2000 018 0.02 0.044 0.075 - - - - - - 024,030 - 0.022 0.048 0.072 0.100 - - 036,042,048 - 0.051 0.070 0.092 0.120 0.152 - 060 - - - - - - 0.086 0.105 0.130 ACCESSORY ELECTRIC HEATERS HEATER kW @ VOLTS! STAGES(kW INTERNAL FAN COIL SIZE HEATING CAR** PART NO. 240V PH OPERATING) CIRCUIT USED WITH @ 230V PROTECTION KFCEH0401 NO3 3 230/1 3 None 018-024 9,400 KFCEH0501N05 5 230/1 5 None 018-060 15,700 KFCEH0801N08 8 230/1 8 None 018-060 25,100 KFCEH0901N10 10 230/1 10 None 018-060 31,400 KFCEH3201 F20 20 230/1 5,20 Fuse$ 030-060 62,800 KFCEH1601315 15 230/3 5,15 None 036-080 47,100 KFCEH2001318 18 230/3 6,12,18 None 042-060 56,500 KFCEH3401F24 24 230/3* 8,16,24 Fuse 048,060 78,300 KFCEH3501F30 30 230/3* 10,20,30 Fuse 048,060 94,100 KFCEH2401C05 5 230/1 5 Circuit Breaker 018-060 15,700 KFCEH2501C08 8 230/1 8 Circuit Breaker 018-060 25,100 KFCEH2601C10 10 230/1 10 Circuit Breaker 018-060 31,400 KFCEH3301C20 20 230/1 5,20 Circuit Breaker 030-060 62,800 KFCEH2901N09 9 230/1t 3,9 None 036-060 28,200 KFCEH3001F15 15 230/1 5,15 Fuse$ 024-060 47,100 KFCEH3101C15 15 230/1 5,15 Circuit Breaker 024-060 47,100 *Field convertible to 1 phase. tField convertible to 3 phase. *Single point wiring kit required for these heaters in Canada. **Blower Motor heat not included. ESTIMATED SOUND POWER LEVEL (dBA) CONDITIONS OCTAVE BAND CENTER FREQUENCY* FB4C CFM Pressure 63 125 260 600 1000 2000 4000 018 600 0.25 64.7 60.7 56.7 53.7 51.7 49.7 45.7 024 800 0.25 66.0 62.0 58.0 55.0 53.0 51.0 47.0 030 1000 0.25 67.0 63.0 59.0 56.0 54.0 52.0 48.0 036 1200 0.25 67.8 63.8 59.8 56.8 54.8 52.8 48.8 042 1400 0.25 68.4 64.4 60.4 57.4 55.4 53.4 49.4 048 1600 0.25 69.0 65.0 61.0 58.0 56.0 54.0 50.0 080 2000 0.25 70.0 68.0 62.0 59.0 57.0 55.0 51.0 *Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems&Applications Handbook,Chapter 52,p. 52.7. 14 PERFORMANCE DATA (cont.) ELECTRICAL DATA FOR UNITS WITH FACTORY-INSTALLED HEAT SINGLE CIRCUIT DUAL CIRCUIT FB4CNF MTR MTR VOLTS/PH/ HEAT PACK HTR. MCA MOCP HTR. MCA MOCP HP FLA HZ INSTALLED Amps MCA MOCP AMPS AMPS L1/L2 L1/L2 L1/L2 L3/L4 LS/L4 L3/L4 018(0,T,L)05 1/3 2.8 208/230/1/60 MKFCEH0501 N05 18.1/20.0 26.1/28.5 30/30 N/A N/A N/A N/A N/A N/A 018(0,T,L)08 1/3 2.8 208/230/1/60 MKFCEH0801 N08 28.9/32.0 39.6/43.5 40/45 N/A N/A N/A N/A N/A N/A 024(0,T,L)05 1/3 4.1 208/230/1/60 MKFCEH0501 N05 18.1/20.0 27.8/30.0 30/30 N/A N/A N/A N/A N/A N/A 024(T,L)10 1/3 4.1 208/230/1/80 MKFCEH0901N10 36.2/40.0 50.4/55.1 60/60 N/A N/A N/A N/A N/A N/A 030(0,7,,L)08 1/3 2.8 208/230/1/60 MKFCEH0801 N08 28.9/32.0 39.8/43.5 40/45 N/A N/A N/A N/A N/A N/A 030(0,T,L)10 1/3 2.8 208/230/1/60 MKFCEH0901N10 36.2/40.0 48.8/53.5 50/80 N/A N/A N/A N/A N/A N/A 036(T,L)10 1/2 4.1 208/230/1/60 MKFCEH0901N10 36.2/40.0 50.4/55.1 60/60 N/A N/A N/A N/A N/A N/A 042(T,L)10 1/2 4.1 208/230/1/60 MKFCEH0901N10 36.2/40.0 50.4/55.1 80/60 N/A N/A N/A N/A N/A N/A 042(T,L)15 1/2 4.1 208/230/1/60 MKFCEH1501F15 54.2/59.9 72.9/80.0 80/80 36.2/40.0 50.4/55.2 50/60 18.1/20.0 22.6/25.0 25/25 048(T,L)10 3/4 6.0 208/230/1/60 MKFCEH0901N10 36.2/40.0 52.8/57.5 80/60 N/A N/A N/A N/A N/A N/A 048(T,L)15 3/4 6.0 208/230/1/60 MKFCEH1501F15 54.2/59.9 75.3/82.4 80/90 36.2/40.0 52.8/57.5 60/60 18.1/20.0 22.6/25.0 25/25 ELECTRICAL DATA FOR UNITS WITHOUT ELECTRICAL HEAT SINGLE CIRCUIT MTR MTR MAXIMUM BRANCH CIRCUIT MODEL NO. HP FLA VOLTS/PH/HZ MIN WIRE SIZE MCA OVERCURRENT AWG PROTECTION FB4CN(F,P)018(0,T,L)00 1/3 2.8 208/230/1/60 3.5 15 14 FB4CN(F,P)024(0,T,L)00 1/3 4.1 208/230/1/60 5.1 15 14 FB4CN(F,P)030(0,T,L)00 1/3 2.8 208/230/1/60 3.5 15 14 FB4CN(F,P)036(0,T,L)00 1/2 4.1 208/230/1/60 5.1 15 14 FB4CN(F,P)042(0,T,L)00 1/2 4.1 208/230/1/60 5.1 15 14 FB4CN(F,P)048(0,T,L)00 3/4 6.0 208/230/1/60 7.5 15 14 FB4CN(F,P)060(0,T,L)00 3/4 6.0 208/230/1/60 7.5 15 14 *Use copper wire only.Use 75°C only in this application.When using non—metallic(NM)sheathed cable,wire size required should be based on that of 80°C conductors,instead of wire sizes shown in table above per NEC Article 338-26. NOTE:If branch circuit wire length exceeds 100 ft(30 m),consult NEC 215-2 to determine maximum wire length.Use 2%voltage drop. FLA—Full Load Amps 15 ACCESSORY ELECTRIC HEATER ELECTRICAL DATA , BRANCH CIRCUITP H INTERNAL 20B/230V HEATER AMPS Min Alnpacity Min Wire Size(AWG) Min Gnd Wire Size Max Fuse/Ckt Bkr Amps Max Wire Length ' HEATER kW 208/230V• 208/230Vt 208/230V 208/230V 208/230V(Ft)n PART NO. A CIRCUIT S PROTECTION &ngb Duel Circuit BIngt Dual Circuit Single Duel Circuit Single Dual Circuit Single Dual Circuit Singe Dual Circuit 240v 208v E Crcuit L1,12 um Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 Circuit L1,L2 L3,L4 KFCEH0401NO3 3 2.3 1 None 10.9/12.0 — — 15.9/17.3 — — 12/12 — — 12/12 — — 20/20 — — 87/88 — — KFCEH0501N051 5 3.8 1 None 18.1/20.0 — — 26.0/28.4 — — 10/10 — — 10/10 — — 30/30 — — 86/86 — — KFCEH0601N062 5 3.8 1 None 18.1/20.0 — — 31.2/33.5 — — 8/e 10/10 — — 35185 85/88 — — KFCEH2401C081 5 3.8 1 Ckt Bkr 18.1/20.0 — — 28.0/28.4 — — 10/10 — — 10/10 — — 30/30 — — 86/88 — — KFCEH2401C052 5 3.8 1 Ckt Bkr 18.1/20.0 — — 31.2/33.5 — — 8/B — — 10/10 — — 35/35 — — 85/88 — — — KFCEH0801N08 8 6.0 1 None 28.9/32.D — — 44.7/48.5 — — 8/B — — 10/10 — — 45/50 — — 59/80 — — KFCEH2501C08 8 6.0 1 Ckt Bkr 28.9/32.0 — — 44.7/48.5 — — 8/8 — — 10/10 45/50 — — 59/80 — — KFCEH2901N09 9 8.8 1 None 32.8/38.0 — — 49.5/53.5 — — 8/6 — — 10/10 — — 50/80 54/87 — — KFCEH2901N09" 9 8.8 3 None 18.8/20.8 — — 32.0/34.5 — — 8/8 10/10 — — 35/35 83/85 — — KFCEH0g01N10 10 7.5 1 None 36.2/40.0 — — 53.8/58.5 — — 8/6 — — 10/10 — — 80/60 7B/80 — — KFCEH2601C10 10 7.5 1 Ckt Bkr 38.2/40.0 — — 53.8/58.5 — — 8/8 — — 10/10 — — 60/80 — — 7B/80 — — KFCEH3001F15 15 11.3 1 Fuse 54.2/59.9 36.2/40.0 18.1/20.0 78.3/83.4 53.13/58.5 22.7/25.0 4/4 6/6 10/10 8/8 10/10 10/10 80/90 80/60 25/25 88/89 78/80 75/78 KFCE113101C15 15 11.3 1 Ckt Bkr — 38.2/40.0 13.1/20.0 — 53.8/58.5 22.7/25.0 — 8/6 10/10 — 10/10 10/10 — 60/60 25/25 — 78/80 75/78 KFCEH1601318 15 11.3 3 None 31.3/34.6 — — 47.7/51.8 — — 8/6 — — 10/10 — — 50/60 56/90 — — KFCEH2001318 18 13.5 3 None 37.8/41.5 — — 55.5/80.4 — — 6/6 — — 10/8 — — 60/70 — — 76/77 — — KFCEH3201F20 20 15.0 1 Fuse 72.3/79.9 38.2/40.0 36.2/40.0 98.9/108.4 53.8/58.5 45.3/50.0 3/2 8/6 8/8 8/8 10/10 10/10 100/110 60/60 50/50 85/109 78/80 59/59 KFCEH3301C20 20 15.0 1 CM Bkr — 38.2/40.0 38.2/40.0 — 53.8/58.5 45.3/50.0 — 8/6 8/8 — 10/10 10/10 — 60/80 50/50 — 78/80 59/59 24 18.0 3 Fuse 50.1/55.4 — — 71.2/77.8 — — 4/4 — — 8/8 — — 80/80 — — 94/95 Cz �KEtf34011'24it 24 18.0 1 Fuse 86.7/95.5 — — 116.9/127.9 — — 1/1 — — 6/6 — — 125/150 — — 115/116 — — 30 22.5 3 Fuse 62.8/69.2 — — 813.8/95.0 — — 3/3 — — 8/8 — — 90/100 — — 97/98 — — KFCEM3501F3Ott 30 22.5 1 Fuse 109.0/120.0 144.8/158.5 — — 0/00 — — 6/8 — — 150/175 — — 117/150 — — FIELD MULTIPOINT WIRING OF 24-AND 30-kW SINGLE PHASE P HEATER AMPS MIN AMPACITY MIN WIRE SIZE(AWG) MAX FUSE/CKT BKR MAX WIRE LENGTH kW H HEATER PART 208/230V 208/230V' 208/230Vt MIN AMPS 208/230V(FT)*SIZ WIRE SIZ NO. A E 208/230V g 208/230V 240V 208V E LIU L3,1.4 LAL8 L1,L2 L3,L4 usu L1,L2 L3,L4 L5,L6 L1,L2 L3,L4 L6,L6 LUZ L9,L4 L6,L6 KFCEH3401F24tt 24 18.0 1 28.9/32.0 28.9/32.0 28.9/32.0 44.7/48.5 382/40.0 36.2/40.0 8/8 8/8 8/8 10/10 45/50 40/40 40/40 59/60 73/73 73/73 KFCEH3501F3Ott 30 22.5 1 38.2/40.0 313.2/40.0 38.2/40.0 53.8/58.5 45.3/50.0 45.3/50.0 6/8 8/8 8/8 10/10 80/60 50/50 50/50 78/80 59/59 59/59 *Includes blower motor amps of largest fan coil used with heater. tCopper wire must be used.If other than uncoated(non—plated),75°C ambient,copper wire(solid wire for 10 AWG and smaller,stranded wire for larger than 10 AWG)is used,consult applicable tables of the National Electric Code (ANSI/NFPA 70). tLenglh shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2/. **Field convertible to 3 phase. ttField convertible to 1 phase,single or multiple supply circuit. NOTES: 1. For fan coil sizes 018-036. 2. For fan coil sizes 042-060. 3. Single circuit application of F15 and F2D heaters requires single—point wiring kit accessory. HEATER ELECTRICAL DATA ELECTRIC HEATER INTERNAL PROTECTION HEATER kW PHASE FUSE CKT BKR• OTY/SIZE OTY/SIZE 5 1 — 1/60 8 1 — 1/60 9 1/3 - — 10 1 — 1/80 15 1 2/30-2/60 2/80 15 3 - — 18 3 - — 20 1 4/80 2/60 24 1/3 8/80 — 30 1/3*All circuit circuit breakers are 2 pole. When using units with 20-, 24-, and 30-kW electric heaters,maintain a 1-in. (25mm)clearance from combustible materials to discharge plenum and ductwork and maintain a distance of 36-in. (914mm) from the unit. Use an accessory downflow base to maintain proper clearance on downflow installations.Use flexible connectors between ductwork and unit to prevent transmission of vibration.When electric heater is installed,use heat resistant material for flexible connector between ductwork and unit at discharge connection. Ductwork passing through unconditioned space must be insulated and covered with vapor barrier ACCESSORIES ITEM ACCESSORY PART NO.* FAN COIL SIZE USED WITH 1. Disconnect Kit KFADK0201 DSC Cooling controls and heaters 3-through 10-kW KFACB0101CFB 018,024 2. Downflow Base Kit KFACB0201 CFB 030,036 KFACB0301CFB 042,048,080 KFADCO201SLP Slope Coil Units-018,024,030,038 3. Downflow Conversion Kit t KFADC0401ACL A-Coil Units-042,048,080 4. Downflow/Horizontal Conversion Gasket Kit KFAHD0101SLP All 5. Horizontal Water Management Kit(25 pack)t KFAHC0125AAA All 6. Single-Point Wiring Kit KFASP0101SPK Only with 15-and 20-kW Fused Heaters KFAFK0112SML 018,024 7. Filter Kit(12 Pack) KFAFK0212MED 030,036 KFAFK0312LRG 042,048,080 FNCCABCC0014 018,024 (FILXXFNC0014) Fan Coil Filter Cabinet FNCCABCC0017 8. (Fan Coil Filter Media) (FIL)0(FNC0017) 030,038 FNCCABCC0021 042,048 080 (FILXXFNC0021) 9. PVC Condensate Trap Ka(50 pack) KFAET0150ETK All 10. Air Cleaner 240-volt Conversion Kit KEAVCO201240 All KFAFRO101FRM 018,024 11. Standard Filter Rack KitKFAFR0201FRM 030,036 KFAFRO301FRM 042,048,080 KFAFRO401FRM NA KSATX0201PUR 018,024,030 12. TXV Kit Puron R-410A KSATX0301PUR 038,042 KSATX0401PUR 048 KSATX0801HSO 018,024,030,038,042 13. TXV Kit R-22 KSATX0701HSO 048 KSATX1001HSO 080 * Factory authorized and listed,field-installed. t KFAHD0101 SLP must also be purchased for downflow applications. KFAHD0101 SLP must also be purchased for downflow or horizontal applications. 17 ACCESSORIES (cont.) Accessory Kits Description Suggested and Required Use 1. Disconnect Kit The kit is used to disconnect electrical power to the fan coil so service or maintenance may be performed safely. SUGGESTED USE: Units for 3-through 10-kW electric resistance heaters and cooling controls. 2. Downflow Base Kit This kit is designed to provide a 1-in.(25mm)minimum clearance between unit discharge plenum,ductwork,and combustible materi- als.It also provides a gap-free seal with the floor. REQUIRED USE:This kit must be used whenever fan coils are used in downflow applications. 3. Downflow Conversion Kit Fan coils are shipped from the factory for upflow or horizontal-left applications.Downflow conversion kits provide proper condensate water drainage and support for the coil when used in downflow applications.Separate kits are available for slope coils and A-coils. REQUIRED USE:This kit must be used whenever fan coils are used in downflow applications. 4. Downflow/Horizontal Conversion Gasket Kit This kit provides the proper gasketing of units when applied in either a downflow or horizontal application. REQUIRED USE:Fan coils in either downflow or horizontal applications. 5. Horizontal Applications-Water Management Kit This kit provides proper installation of fan coils under conditions of high static pressure and high relative humidity. SUGGESTED USE: All fan coils. 6. Single Point Wiring Kit The single point wiring kit acts as a jumper between Ll and L3 lugs,and between the L2 and L4 lugs.This allows the installer to run two heavy-gauge,high-voltage wires into the fan coil rather than 4 light-gauge,high-voltage wires. SUGGESTED USE:Fan coils with 15-and 20-kW fused heaters only. 7. Filter Kit(12 pack) The kit consists of 12 fan coil framed filters. These filters collect large dust particles from the return air entering the fan coil and prevents them from collecting on the coil. This process helps to keep the coil clean, which increases heat transfer and, in turn, the efficiency of the system. SUGGESTED USE:To replace filters in fan coils. REQUIRED USE:All units unless a filter grille is used. 8. Fan Coil Filter Cabinet This cabinet is mounted to the fan coil on the return air end and designed to slip over the outer fan coil casing. The cabinets are insulated using the same insulation as production fan coils.They are designed for the removal of particulates from indoor air using FILXXFNC00(14,17,21,24)media filter cartridges.These fan coil media filter cartridge kits are designed for the removal of particles from indoor air.The cartridge is installed in the return air duct next to the air handler or further upstream. SUGGESTED USE: All fan coils. 9. Condensate Drain Trap Kit This kit consists of 50 PVC condensate traps.Each trap is pre-formed and ready for field installation.This deep trap helps the system make and hold proper condensate flow even during blower initiation. SUGGESTED USE:All fan coils. 10. Air Cleaner 240-volt Conversion Kit The AIRA electronic air cleaner comes ready for 115-v operation. REQUIRED USE:This kit is required when running 240-volt circuit to air cleaner. 11. Standard Filter Rack Kit This kit mounts in fan coil filter rack area and modifies the existing filter rack to support standard 1-in.filter sizes. SUGGESTED USE:Fan coils using standard filter sizes. ©2014 Bryant Heating&Cooling Systems a 7310 W.Morris St.s Indianapolis,IN 46231 Edition Date: 02/14 U.S.Export Classification:EARN. Catalog No. PDSFB4CNF-08 Manufacturer reserves the right to discontinue,or change al any time,specifications or designs without notice and without incurring obligations. Replaces:PDSFB4CNF-07 18 BRêAN ` ,u SPECIFICATION SHEET REG <<, 3 0 2020 MODELS A80, A110NcaT,?`q+"y le4�\]* \' .14 FLEXTM SERIES FANS DESCRIPTION TYPICAL SPECIFICATION BLOWER: Fan shall be Broan Model A80(A110). • Plug-in, permanently lubricated motor-engineered for Fan shall have corrosion resistant galvanized steel housing continuous operation with four-point mounting capability. It shall be ducted to a • Dynamically balanced centrifugal blower wheel for quiet, roof or wall cap using 4"round ductwork. efficient performance Blower assembly shall be removable, have a centrifugal- • Low RPM for quiet operation type blower wheel and a permanently lubricated motor HOUSING: designed for continuous operation. • Rugged, 26 gauge, galvanized steel construction Non-metallic damper/duct connector shall be included. • Polymeric,4"duct connector with tapered sleeve and no Air delivery shall be no less than the airflow values and metallic clatter no greater than the sound level values listed in the HVI • 53/4"height allows for 2"x 6"ceiling installations Performance Specifications provided in this specification • Sturdy, easy,four-point mounting directly to joist (see following chart).All air and sound ratings shall be • Can be mounted in ceilings up to 7/12 pitch certified by HVI. • Can be installed in a wall if mounted 8-ft.or more above Ceiling Ventilator shall be U.L.Listed for use over bathtubs the floor and showers when connected to a GFCI protected branch GRILLE: circuit. • Polymeric construction • Innovative design-the result of extensive research with designers and consumers CONTROLS(Purchase separately): 2100 M, • Refer to Broan's catalog for a complete line of n UL us liv, accessories to effectively adapt these fans to your y CERTIFIED construction requirements. U.L. Listed for use over bathtubs and showers when connected to a GFCI protected branch circuit(ceiling mount only). 1-Year Warranty Broan Hartford,Wisconsin www.broan.com 800-558-1711 Venmar Ventilation ULC Drummondville(Quebec), Canada www.broan.ca 877-896-1119 REFERENCE QTY. REMARKS Project Location Architect Engineer Contractor Submitted by Date 91D 99045370D PERFORMANCE RATINGS - FLEXTM SERIES FANS HVI PERFORMANCE ELECTRICAL & WEIGHT 0.1 Ps-Static Pressure(in.H20) 0.25 Ps Model Volts Hz Amps Shipping Model Airflow Sound Power Efficacy Airflow Weight (CFM) (Sones) (Watts) (CFM/W) (CFM) A80 120 60 0.37 10.0 lb. • A80 80 2.0 43.1 1.89 67 A110 120 60 0.40 10.0 lb. A110 110 3.0 47.3 2.36 102 ® HVI-2100 CERTIFIED RATINGS comply with new 2100 II- testing technologies and procedures prescribed by the H V Home Ventilating Institute,for off-the-shelf products,as they are available to consumers.Product performance is rated at 0.1 in. static pressure, based on tests CERTIFIED conducted in a state-of-the-art test laboratory.Sones AIR FLOW PERFORMANCE are a measure of humanly-perceived loudness,based on laboratory measurements. Model A80 0.6 3 0.5 �....... C � US m . co c� rum 0.4 m ° 0.3 0. Le V L �f �� 0 co` 0.2 - 0 .��. al . I 0.1 a if I � \ r . 1° 0.0 ��d I a� 0 10 20 30 40 50 60 70 80 90 100 1111111111,1I �' • ` (�` Air Flow(CFM-Cubic Feet per Minute) I1 �rl-t� ® 4 �� Model A110 A \ / 0.7 �j/ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIU11111111111111111 111111111I1111111111111111111111111111111111111llllll111111111111 IIIIIIIIIIIIIIII11 IIIII11 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII111 IIIIIII 4. § 0.6 1111 1 irisri1ii1riri111111111111111111iii riln11111111111111 6' 0 5 IIIIIIIIIIl::VIIIIIIIII111111111u1111111111111111111111111111u III11nnn11n.:■In1IIIUIImllnmu11m11n1111nnn111I /• CL 0 1IIIIIIIIIIII1111I10■ 9Iu1u111111111I111111/u1111111I11111tu \ IIIu1uII1111I11uI1III1.:1u1I111111u11I11nnn11l11uulull Y / m 11111111111111111111111IIlII.:9Iluliu1111un11111111111111111 \� ra 0.4 IlulluII/1IIIIIIIu1111I11IIh Iu1II11IlIIIIII111111111u11111 r.i 111I1I1111111111IIII111111111111111011I11IIII11I1I1111II1111111I IIIIIIIIIIIIIIIIII11I11IIIIII111111IItu4I1II1I11IIIIIIlI111111111 o I/1I11111I11I1111I1111111I111111I1111II1:!11111111111I11I1I111I11 NOTE:Dimensions shown are in inches. a w IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIG'IIIIIIIl1IIII1111111I °2 02 IIIIIIIIu11IuI1111u11111u111IlIllllaul11111u/111u11 ° uunnmuulmnnnuunnmumuumanuunnnuu c 11111111u1111u1111u111u1u111111111111I1u111:u111u111111u to= 111111111111111111111111111111Iluullll111111111111►11111111111111 11111111111111111111I11111111III11I11/11111111I111111111111/11I11 O 0.2 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII111IIIIIIIIIIIlIl11III x 11IIIII1111111IIIII111111111111111I1111I11I1II11III11II1111I11I1I Illl1II111111111111111111111111111111111111111111111,1111111Iuulul IIIIIlu11111I1IIII11I1111I11111I111111111111111111111111111111I11 " IIII11I11111IIIIIl11I11111111111I1111I1111I1111111I169111111111I 0.1 IIIIIIIIIIIIIIIIIIIIIIII111111I1111111I11111111111I111'111111I111 1I1I11I11I11III11I11111III11IIII11111I1111I11111I1111I1.7I111IIII 111111111I1111111111111I1I11I1II1111IIuuuuu11I11I1111111011111111 111111111111I111111111111111I11111111I111111111111111111111I11111 0.0 IIIIIIIIII111111111111111111I1111111111I1111111111I1IIIIIII6IIII 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Air Flow(CFM-Cubic Feet per Minute) BROAN Broan Hartford,Wisconsin www.broan.com 800-558-1711 r� Venmar Ventilation ULC Drummondville(Quebec), Canada www.broan.ca 877-896-1119 214D Legacy'" Line Heat Pump Lbryant_] - with Puron® Refrigerant 1-1/2 To 5 Nominal Tons Product Data RECEIVED MAR 3 0 2020 INDUSTRY LEADING CITY OF-Pc ARD FEATURES/ BENEFITS HJfLDIN(DIVISION "' — .. - "r Efficiency • 14 SEER/11.5 - 11.7EER/8.2HSPF �+ I -i I' • Microtube Technology refrigeration system 1 � ������� • Indoor air quality accessories available 11111 I . IL C` Sound I� � �, �� ��� , • Sound level as low as 69 dBA .. {I ail I I'11 III • Sound levels as low as 68 dBA with accessorysound blanket 1111 t1IIII I ' Comfort , I I'4 1' l • System supports Housewise""or standard thermostat controls 1 ,414_111 1 III �� Reliability I1 11 1I , IIII • Puron®refrigerant-environmentally sound,won't deplete the 1 �I 1 ozone layer and low lifetime service cost. Iy i • Scroll compressor L'- J • Internal pressure relief valve • Internal thermal overload • High pressure switch fit • Loss of charge switch Puron. • Filter drier • Balanced refrigeration system for maximum reliability Durability Bryant heat pumps with Puron®refrigerant provide a collection of DuraGuard " protection package: features unmatched by any other family of equipment. The 214D • Solid,durable sheet metal construction has been designed utilizing Bryant's Puron refrigerant. The environmentally sound refrigerant allows consumers to make a • Dense wire coil guard responsible decision in the protection of the earth's ozone layer. • Baked-on powder paint NOTE: Ratings contained in this document are subject to Applications change at any time. Always refer to the AHRI directory • Long-line-up to 250 feet(76.20 m)total equivalent length,up (www.ahridirectory.org) for the most up-to-date ratings to 200 feet(60.96 m)condenser above evaporator,or up to 80 ft. information. (24.38 m)evaporator above condenser(See Longline Guide for more information.) • Low ambient(down to-20°F/-28.9°C)with accessory kit MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A NIN N N N N A/N A/N N A 2 1 4 D N A 0 3 6 0 0 0 0 Prod- Tier SEER Major Voltage Grille Cooling Capacity Open Open Open Minor uct Series Variations Series Family 2=HP 1= 4=14 SEER D=Puron N=208/23 A=Dense 1,000 Nominal Btuh O=Not 0=Not 0=Not A= Legrac- 0-1 Defined Defined Defined Original y P=208/230 Series RNC —3 E=460/3 ® rill CERTIFIED. C UL us Puron Use of the AHRI Certified TM Mark Indicates a manufacturer's partidpelbn in the program For verification of certification for Individual product,go to www.anddaeaory.org. STANDARD FEATURES Feature 18 24 30 38 42 48 80 Puron Refrigerant X X X X X X X Scroll Compressor X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Suction Line Accumulator X X X X X X X High Pressure Switch X X X X X X X Loss of Charge Switch X X X X X X X X=Standard 2 PHYSICAL DATA UNIT SIZE SERIES 18-A I 24-A I 30-A 38-B I 42-A I 48-A I 80-A . Compressor type Scroll REFRIGERANT Purone(R-410A) Control TXV(Puron Hard Shutoff) Charge lb(kg) 5.3(2.4) I 5.8(2.5) I 8.4(2.9) I 7.87(3.48) I 8.25(3.74) I 8.88(3.94) I 10.8(4.81) COND FAN Forwrard Swept or Propeller Type,Direct Drive Air Discharge Vertical Motor HP 1/12 1/10 1/4 1/5 1/4 1/4 1/4 Motor RPM 1100 1100 1100 1100 1100 1100 800 VALVE CONNECT.(In.ID) Vapor 5/8 j 5/8 3/4 3/4 I 7/8 I 7/8 I 7/8 Liquid 3/8 REFRIGERANT TUBES*(In.OD) Rated Vapor 5/8 I 5/8 I 3/4 I 3/4 I 7/8 I 7/8 I 1-1/8 Max Liquid Line 3/8 *Units are rated with 25 ft(7.8 m)of lineset length. See Vapor Line Sizing end Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for HP systems with Puron refrigerant: Vapor Line Sizing and Cooling Capacity Losses-Puron®Refrigerant 1-Stage Heat Pump Applications Acceptable Totall Cooling Capacity LineLoss Le egthh(ft) Unit Nominal Size Vapor Line (Stith) Diameters Standard Application (In.OD) 25 50 80 (7.82) (152) (24A) 18000 1/2 1 2 3 1-Stage HP 5/8 0 0 1 24000 5/8 0 1 1 1-Stage HP 3/4 0 0 0 5/8 1 2 3 30000 3/4 0 0 1 1-Stage HP 7/8 0 0 0 5/8 1 2 4 38000 3/4 0 0 1 1-Stage HP 7/8 0 0 0 42000 3/4 0 1 2 ®_ 1-Stage HP 7/8 0 0 1 2 2 2 3 3 48000 3/4 0 1 2 5 5 I 8 i 7 8 1-Stage HP 7/8 0 0 1 2 2 3 13 4 3/4 1 2 4 4 5 8 .,.:..a 7 9 10 11__-- 12 60000 7/8 0 1 2 2_ 2 3 4 4 . 5 5 8 1-Stage Puron HP _ _ 11/8 0 0 0 r,. 0-. 1 1 IIIMINIMIIMIRIMMINNIMI Standard Length=80 ft.(24.4 m)or less total equivalent length tT,.,-„+y,, ar- _ r. l too -, 3 REFRIGERANT PIPING LENGTH LIMITATIONS Maximum Line Lengths: The maximum allowable total equivalent length for heat pumps varies depending on the vertical separation. See the tables below for allowable lengths depending on whether the outdoor unit is on the same level,above or below the outdoor unit. Maximum Line Lengths for Heat Pump Applications MAXIMUM ACTUAL LENGTH MAXIMUM EQUIVALENT LENGTHt MAXIMUM VERTICAL ft(m) ft(m) SEPARATION ft(m) Units on equal level 200(61) 250(78.2) N/A Outdoor unit ABOVE 200(61) 250(76.2) 200(61) indoor unit Outdoor unit BELOW See Table'Maximum Total Equivalent Length:Outdoor Unit BELOW Indoor Unit' Indoor unit t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. Maximum Total Equivalent Lengtht-Outdoor Unit BELOW Indoor Unit Liquid Line HP with Puron*Refrigerant-Maximum Total Equivalent Lengtht Size Diameter Vertical Separation ft(m)Outdoor unit BELOW Indoor unit; wlTXV 0-20 21-30 31-40 41-50 51-80 61-70 71-80 (0-6.1) (6.4-9.1) (9A-122) (12.5-152) (15.5-18.3) (18.8-21.3) (21.8-24.4) 18000 HP with 3/8 250* 250* 250* 250* 250* 250* 250* Puron 24000 HP with 3/8 250* 250* 250* 250* 250* 250* 250* Puron 30000 HP with 3/8 250* 250* 250* 250* 250* 250* 250* Puron 36000 HP with 3/8 250* 250* 250* 250* 250* 250* 250* Puron 42000 HP with 3/8 250* 250* 250* 250* 250* 250* 150 Puron 48000 HP with 3/8 250* 250* 250* 250* 230 160 -- Puron 60000 HP with 3/8 250* 225* 190 150 110 -- -- Puron * Maximum actual length not to exceed 200 ft(61 m) t Total equivalent length accounts for losses due to elbows or fitting.See the Long Line Guideline for details. -- =outside acceptable range LONG LINE APPLICATIONS An application is considered Long Line when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. Defining a system as long line depends on the liquid line diameter,actual length of the tubing, and vertical separation between the indoor and outdoor units. For Heat Pump systems,the chart below shows when an application is considered Long Line. Beyond these lengths,long line accessories are required: HP WITH PURON®REFRIGERANT LONG LINE DESCRIPTION ft(m) Beyond these lengths,long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 3/8 80(24.4) 20(6.1)vertical or 80(24.4)total 80(24.4) Note: See Long Line Guideline for details 4 ACCESSORIES ORDER NUMBER DESCRIPTION 18-A 24-A 30-A 38-B 42-A 48-A 80-A HC32GE234 BALL BEARING FAN MOTOR X HC34GE240 BALL BEARING FAN MOTOR X HC38GE219 BALL BEARING FAN MOTOR X HC4OGE228 BALL BEARING FAN MOTOR X X X HC40GE228 BALL BEARING FAN MOTOR X KAACH1601AAA CRKC HTR KIT X X KAACH1701AAA CRKC HTRKIT X X X X KAACS0201 PTC KIT PTC X X X X X X X KAAFT0101AAA FTC THERM KIT X X X X X X X KAATD0101TDR TIME DELAY KIT X X X X X X X KHAIR0201AAA ISLN RELAY KIT X X X X X X X KHALSO401 LLS SOL VALVE KIT X X X X X X X KHAOT0201 SEC OUTDR THERM KIT X X X X X X X KHAOT0301 FST OUTDR THERM KIT X X X X X X X KHASS0606MPK SNOW STAND KIT X X X X X X X KSACY0101AAA CYCLE PROTR KIT X X X X X X X KSAHS1701AAA HARD START KIT X X X X X X X KSALA0301410 LOW AMBIENT KIT X X X X X X X KSALA0601AAA MOTORMASTER KIT X X X X X X X KSASF0101AAA SPRT FEET KIT X X X X X KSASF0201AAA SPRT FEET KIT X X KSASH0601COP SOUND BLKT KIT X X X X X KSASH2101COP SOUND BLKT KIT X X KSATX0201 PUR TXV KIT(for copper coils) X X X KSATX0301 PUR TXV KIT(for copper coils) X X KSA1X0501 PUR TXV KIT(for copper coils) X X KSBTX0201PUR TXV KIT(for aluminum coils) X X- X KSBTX0301 PUR TXV KIT(for aluminum coils) X X KSBTX0401 PUR TXV KIT(for aluminum coils) X X x=Accessory ACCESSORY THERMOSTATS Capabilities Heat Cool Part Number Description Heat Gas Bettie El Stages Stages Pump T6-WEM01 Housewise'Wi-A Programmable Relative Humidity Thermostat y y y 4 2 T8-PRH01-A Programmable Relative Humidity Thermostat y y y 3 2 TB-PHP01 Programmable Thermostat(HP or AC) y y 3 2 T6-NRH01-A Non-Programmable Relative Humidity Thermostat y y y 3 2 78-NHP01 Non-Programmable Thermostat(HP or AC) y y 3 2 T2-WHS01 Wi-FP Programmable y y y 3 2 T2-PHP01 5-2 Day Programmable Thermostat y y 3 2 T2-NHP01 Non-Programmale Thermostat (HP or AC) V V 3 2 T2SNHP01 Non-Programmable Thermostat (HP or AC) y y 2 1 T1-PHP01 5-2 Day Programmable Thermostat y y y 2 1 T1-NHP01 Non-Programmable Thermostat(HP or AC) V V V 2 1 Thermostat Accessories Part Number Description Used With TO-EXPO1-A ExPs Computer Programming Accessory TO-P thermostats TSTATXXCNV10 Thermostat Conversion Kit(4 to 5 wire) -10 pack All Bryant branded thermostats TX-LBP01 Large Decorative Backplate TB-Pxx,T6-Nxx,and T2-Pxx TX-MBP01 Medium Decorative Bookplate T2-Nxx and T1-Pxx TX-SBP01 Small Decorative Backplate T1-Nxx TSTATXXSEN01-B• Outdoor Air Temperature Sensor All TO-thermostats 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR LOW-AMBIENT REQUIRED FOR AccessoryCOOLING APPLICATIONS REQUIRED FOR SEA COAST APPLICATIONS (Below 55°F/12.8°C) LONG LINE APPLICATIONS* (Within 2 miles/3.22 km) Accumulator Standard Standard Standard Ball Bearing Fan Motor Vest No No Compressor Start Assist Capacitor and Yes Yes No Relay Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Hard Shutoff TICV Yes Yes No Isolation Relay Yes No No Liquid Line Solenoid Valve No See Long-Une Application Guideline No Motor Master®Control or Low Ambient Switch Yes No No Support Feet Recommended No Recommended *For tubing line sets between 80 and 200 ft.(24.38 and 60.96 m) and/or 20 ft.(6.09 m)vertical differential,refer to Residential Split-System Longline Application Guideline. t Additional requirement for Low-Ambient Controller(full modulation feature)MotorMasters Control. Accessory Description and Usage(Listed Alphabetically) 1.Ball-Bearing Fan Motor 6. Isolation Relay A fan motor with ball bearings which permits speed reduction An SPDT relay which switches the low-ambient controller out of while maintaining bearing lubrication. the outdoor fan motor circuit when the heat pump switches to Usage Guideline: heating mode. Required on all units when using MotorMaster® Usage Guideline: 2.Compressor Start Assist-Capacitor and Relay Required in all heat pumps where low ambient kit has Start capacitor and relay gives a hard boost to compressor motor at been added. each start up. 7.Liquid-Line Solenoid Valve(LLS) Usage Guideline: An electrically operated shutoff valve which stops and starts Required for reciprocating compressors in the following refrigerant liquid flow in response to compressor operation.It is to applications: be installed at the outdoor unit to control refrigerant off cycle Long line migration in the heating mode. Low ambient cooling Usage Guideline: An LLS is required in all long line heat pump Hard shut off expansion valve on indoor coil applications to control refrigerant off cycle migration in Liquid line solenoid on indoor coil the heating mode.See Long Line Guideline. Required for single-phase scroll compressors in the 8.Low-Ambient Pressure Switch Kit following applications: A long life pressure switch which is mounted to outdoor unit Long line service valve.It is designed to cycle the outdoor fan motor in order Low ambient cooling to maintain head pressure within normal operating limits. The Suggested for all compressors in areas with a history of control will maintain working head pressure at low-ambient low voltage problems. temperatures down to 0°F(-18°C)when properly installed. 3.Compressor Start Assist—PTC Type Usage Guideline: Solid state electrical device which gives a soft boost to the A Low-Ambient Pressure Switch or MotorMaster® compressor at each start-up. Low-Ambient Controller must be used when cooling Usage Guideline: operation is used at outdoor temperatures below 55°F (12.8°C). Suggested in installations with marginal power supply. g,MotorMaster®Low-Ambient Controller 4.Crankcase Heater A fan-speed control device activated by a temperature sensor, An electric resistance heater which mounts to the base of the designed to control condenser fan motor speed in response to the compressor to keep the lubricant warm during off cycles.Improves saturated, condensing temperature during operation in cooling compressor lubrication on restart and minimizes the chance of mode only.For outdoor temperatures down to-20°F(-28.9°C),it liquid slugging. maintains condensing temperature at 100°F ±10°F (37.8°C ± Usage Guideline: 6.5°C). Required in low ambient cooling applications. Usage Guideline: Required in long line applications. A MotorMaster® Low Ambient Controller or Suggested in all commercial applications. Low-Ambient Pressure Switch must be used when 5.Evaporator Freeze Thermostat cooling operation is used at outdoor temperatures An SPST temperature-actuated switch that stops unit operation below 55°F(12.8°C). when evaporator reaches freeze-up conditions. Suggested for all commercial applications. Usage Guideline: Required when low ambient kit has been added. 6 Accessory Description and Usage (Listed Alphabetically) - CONTINUED 10.Outdoor Air Temperature Sensor 14.Sound Hood Designed for use with Bryant Thermostats listed in this Wraparound sound reducing cover for the compressor.Reduces the publication. This device enables the thermostat to display the sound level by about 2 dBA. outdoor temperature.This device also is required to enable special Usage Guideline: thermostat features such as auxiliary heat lock out. Suggested when unit is installed closer than 15 ft. Usage Guideline: (4.577 m)to quiet areas,bedrooms,etc. Suggested for all Bryant thermostats listed in this Suggested when unit is installed between two houses less publication. than 10 ft.(3.05 m) apart. 11.Outdoor Thermostat 15.Thermostatic Expansion Valve(TXV)Bi-Flow An SPDT temperature-actuated switch which turns on A modulating flow-control valve which meters refrigerant liquid supplemental electric heaters when outdoor air temperature drops flow rate into the evaporator in response to the superheat of the below a user-selected set point. refrigerant gas leaving the evaporator. Usage Guideline: Usage Guideline: Electric supplemental heat applications in non-variable Accessory required to meet AHRI rating and system speed indoor units when electric heat staging is desired. reliability,where indoor not equipped. 12.Secondary Outdoor Thermostat Required in all heat pump applications designed with An SPDT temperature-actuated switch which turns on third-stage Puron refrigerant. of supplemental electric heaters when outdoor air temperature 16.Time-Delay Relay drops below the second-stage set point. An SPST delay relay which briefly continues operation of indoor Usage Guideline: blower motor to provide additional cooling after the compressor Outdoor thermostat applications where electric heater is cycles off. capable of 3-stage operation. Note:Most indoor unit controls include this feature.For those that 13.Snow Stand Rack do not,use the guideline below. Coated wire rack which supports unit 18 in. (457.2 mm) above Usage Guideline: mounting pad to allow for drainage from unit base. Accessory required to meet AHRI rating,where indoor Usage Guideline: not equipped. Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. • ELECTRICAL DATA OPER VOLTS* COMPR FAN MAX or ' UNIT SIZE V/PH MCA FUSE**K MAX MIN LRA RLA FLA CA BR AMPS 18 48.0 9.0 0.50 11.8 20 24 82.9 10.9 0.60 14.2 25 30 72.5 13.5 1.40 18.3 30 38 208/230/1 253 197 75.0 14.7 1.10 19.5 30 42 105.5 15.5 1.40 24.0 40 48 108.0 19.0 1.40 25.2 40 60 144.2 - 24.4 1.52 32.0 50 * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time-Delay fuse. FLA - Full Load Amps LRA - Locked Rotor Amps MCA- Minimum Circuit Amps RLA - Rated Load Amps NOTE:Control circuit is 24-V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1 A-WEIGHTED SOUND POWER STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA,without tone adjustment) UNIT SIZE RATING (dBA) 125 260 600 1000 2000 4000 8000 18 69 45 48 58 82 55 53 47 24 78 48 56 59 63 63 60 55 30 77 52 62 87 68 65 62 55 96 77 51 82 66 69 84 61 53 42 76 49 61 63 85 82 60 52 48 79 53 66 69 71 67 64 57 60 73 50 83 62 63 60 58 52 NOTE: Tested In accordance with AHRI Standard 270-08(not listed in AHRI). A-WEIGHTED SOUND POWER WITH SOUND HOOD UNIT SIZE STANDARD TYPICAL OCTAVE BAND SPECTRUM(dBA,without tone adjustment) RATING 126 260 500 1000 2000 4000 8000 18 e8 47 48 56 61 55 52 46 24 74 47 57 59 62 61 58 51 30 77 52 62 67 67 e5 62 54 38 78 52 62 66 67 e4 60 52 42 74 50 61 63 64 81 58 49 48 79 54 66 69 70 87 64 56 80 73 51 84 82 83 59 58 49 NOTE: Tested in accordance with AHRI Standard 270-08(not listed In AHRI). CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING°F CC) 18 11 (6.1) 24 11 (6.1) 30 10(5.6) 36 10(5.6) 42 10(5.6) 48 14(7.8) 60 15(8.3) HP ONLY REPLACEMENT WITH PISTON INDOORS When the 214D is used as a replacement component in a system with a piston fan coil,use the indoor piston size specified below: UNIT SIZE PISTON SIZE FB4CNF FFM FPMA 18 0.052 0.050 0.050 24 0.057 0.057 0.056 30 0.087 0.070 0.087 36 0.070 0.072 0.069 42 0.078 48 0.084 60 =N/A 8 DIMENSIONS - ENGLISH NIPPING SNPPING lAlfT SERFS CHARACTERISTICS A B C D E F G K L M N P TRICAL CPEFUVMOWMx) W ) t*EIIS1ONS IL x W x H) 2146018 A X 0 0 0 23 1/8' 35 1/4" 3 3/4' _518"_ 4 1/46' 18 I/16' T 13/16' 2 13/16" 1/2" 11" 15 3/4' 12' 136 166 25 1/4" X 25 1/4' X 40' 2140024 A X 0 0 0 25 3/4" 35 1/1" 3 3/4' sir 4 7/16' 21 114' 1 1/8' 2 13/16' 1/2" 12' 13 1/4' 13 1/2' 144 175 27 7/8" X 21 7/8' X 40' 2140030 A K 0 0 0 31 3/16' 31 13/16' 3 3/4' 3/4' 6 9/16' 24 11/16' 9 1/8" 2 15/16' 5/8" 15" 11' 16' 158 - 180 33 3/8' X 33 3/8' X 36 5/8' 2146036 D X 0 0 0 31 3/16' 28 7/16' 3 3/4' 3/4' 6 9/16' 24 11/16" 9 1/8' 2 15/16' 5/8' 15 3/4' 14' 10 3/4' 170 201 33 3/8' X 33 3/8• X 33 1/4• 2140042 A X 0 0 0 31 3/16' 39 1/8' 3 7/8' 7/8' 6 9/16' 24 11/16' 9 1/8' 2 15/16" 5/8' _15 1/2" 13 1/2' 14' 201 235 33 3/8' X 33 3/8' X 43 1/2' 2140048 A X 0 0 0 31 3/16" 28 7/16' 3 7/8' 7/8' 6 9/16' 21 11/16' 9 1/8' 2 15/16' 5/8' 16 1/2" 11 1/2' 15' 197 232 33 3/8" X 33 3/8' X 33 1/4' 2146060 A X 0 0 QQ0 31 3/16' 31 13/16' 3 7/8' 7/8' 6 9/16' 24 11/16" 9 1/8' 2 15/16' 5/8" to 3/4' 15 3/4' 16 1/4" 212 248 33 3/8' X 33 3/8" X 36 5/8' § j, 9r X = TES 2i�i55 � i 0 = x0 1 AQ. M AIR IN AIR DISCHARGE G AIR DISCHARGE r'r \ i I I' % ;\ to lierf lit: FIELD CONTROL AIR IN— , iti;� I� • •,1�1 F B SUP718'CROLE �Aimio, A 1 _`����� —AIR IN FIELD POWER SUPPLY CONK. ���- 0 7/8' HOLE WITH �� Q11 ve• KNOCKOUT rA �� N LIQUID LINE CONN. 0 P 3 13/16• • �4��� E C 3 1/2' 4 + + a.► 1 7/8' )' 1 118'--o- op VAPOR LINE CONK. II Yso. I K [AIR IN F X SO. 03/8' TIEDOWN KNOCKOUTS (21 PLACES '1C MN OROl9D Y NN NOOFIXP When installing,allow sufficient spacefor airflow clearance,wiring,refrigerant i in and service.Allow 24 in.(609.6 UNIT SIZE MAIM PAD NWWArIW6 PAD n9. piping,9 mm) APPLICATION APRACATIONI clearance to service end of unit and 48 In.(1219.2 mm)(above unit.For proper airflow,a 6—in.(152.4 mm)clearance on 1 dBBQ6 ONSIMON16 side of unit and 12—in.(304.8 mm)on all remaining sides must be maintained.Maintain a distance of 24 in.(809.8 mm) 18 23 1/8' 17 3/4' between units or 18 in.(457.2 mm)if no overhang withIn 12 ft.(3.66 m)Position so water,snow,or ice from roof or eaves 24 25 3/4' 20 7/16- cannot fall directly on unit. 30,37,42,48.60 31 3I16' 23" NOTE:18"(457.2 mm)clearance option described above is approved for outdoor units with wire grille coil guard only.Units 35" 26 3/4' with louver panels require 24'(609.8 mm)between units. On rooftop applications,locale unit at least 6 in.(152.4 mm)above roof surface. DIMENSIONS - SI . ELECTRICAL IIT SERIES C 5 A B C D E F 0 K L M N POPERATING WBOHT ) SHIPPING W x Hl 2140018 A X 0 0 0 587.4 895.4 95.2 15.9 112.7 458.8 198.4 71.4 12.7 279.4 400.1 304.8 61.7 75.3 641.5 X 641.5 X 1016.9 2140024 A X 0 0 0 654.0 895.4 _95.2 15.9 112.7 539.8 231.8 71,4 12.7 304.8 336.6 342.9 65.3 79.4 708.0 X 708.0 X 1016.9 210030 A X 0 0 0 192.2 808.0 95.2 19.0 166.7 621.1 231.8 74.6 15.9 381.0 279.4 406.4 71.7 81.6 846.6 X 846.6 X 930.6 2140036 8 X 0 0 0 192.2 722.3 95.2 19.0 166.7 627.1 231.8 74.6 15.9 400.1 355.6 273.1 77.1 91.2 846.6 X 846.6 X 844,2 214D042 A X 0 0 0 792.2 993.8 98.4 22.2 166,7 621.1 231.8 14.6 15.9 393.7 342.9 355.6 91.2 106.6 846.6 X 846.6 X 1103.3 2140048 A I 0 0 0 712.2 722.3 98.4 22.2 166,7 627.1 231.8 74.6 15.9 419.1 292.1 381.0 89.4 105.2 846.6 X 846.6 X 844.2 _ 2t4D060 A 0 0 0 0 792.2 808.0 18,4 22.2 166.7 627.1 231.8 74.6 15.9 374.7 400.1 412.8 _ 96.2 112.5 846.6 X 846.6 X 930,6 X = YES `N+ 0 = NO _ Ao. M AIR IN AIR DISCHARGE G AIR DISCHARGE \ f / ImussermillasyN Nipoij A `.r z ✓. �A .gym, !! .: FIELD CONTROL kt,47,10/)!� �i � AIR INS SUPPLT CONN. , IB022.23 HOLE . Ip FIELD POWER SUPPLY CONN. % -AIA IN f1i 2.23 HOLE WITH w��, �� za.sa KNOCKOUT '``\., �/ N 09.53NN ,�\�L[OUID LIME CONN. _, P Q\\ �_._ - O 96.8 y0, >��� / E C 88.9 . in r. o 1 i 3 d, 47.6 L _ 28.6 OD VAPOR LINE CONN. , X 0 I K AIR IN _( 09.53 TIEOONN KNOCKOUTS 127 PLACES 'X'NM=IM Y 1.9 ROtF TP When installing,allow sufficient space for airflow clearance,wiring,refrigerant piping,and service.Allow 24 in.(609.6 mm) UNIT WE N101117940 301 TaNIN10 PAD clearance to service end of unit and 48 In.(1219.2 mm)(above unit.For proper airflow,a 6-in.(152.4 mm)clearance on 1 O MOf6 �8i1 6 side of unit and 12-in.(304.8 mm)on all remaining sides must be maintained.Maintain a distance of 24 in.(609.8 mm) 18 587.4 45t.3 between units or 18 In.(457.2 mm)if no overhang within 12 ft.(3.66 m)Position so water,snow.or ice from roof or eaves cannot fall directly on unit. 24 654.0 518,5, NOTE:18"(457.2 mm)clearance option described above Is approved for outdoor units with wire grille coil guard only.Units 30,37,42,18,60 792.2 583.2 with Iouver panels require 24"(609.6 mm)between units. 889.0 679.7 On rooftop applications,locate unit at least 6 in.(152.4 mm)above roof surface. CLEARANCES Clearances (various examples) Wall Wall 6" 152.4 24" (609.6) 24" 12„ Service (609.6) (304.8) Service 12" 6„ Ell (304.8) 152.4) -- 12" (304.8) 12" (304.8) Wall 24" 24" 24" (609.6) (609.6) (609.6) Service Service Service / 18" 18" 18" (457.2) (457.2) (457.2) Note: Numbers in () = mm IMPORTANT. When installing multiple units in an alcove,roof well,or partially enclosed area,ensure there is adequate ventilation to prevent re-circulation of discharge air. BALANCE POINT WORKSHEET 80 1 I 1 I I I I I I { I I I I 1 1 I I I I I I I I 1 I 1 I I I I I I I I I 23.4 --1-+-I--I---t-F--1-+---1-t-t--1---+-1-1-t---I--I-----1---+-1--I-t- -I--f-+-1---t----I--F---1--1-+-I S __1_1_1_-1---1--LJ-1--_1--L-J--1----1--1-_1- ----I-_L-1--1--- 1--1---1--1.- -I---1--1--L---1_-L-I-4---L-1-1-I H1 1 1 1 11 I I II _ III 11 1 I _ 1 1 1 1 1 I I I 11 I I 1 1 I I I- --1-T r 1 1 I 1 I 1 -1- 1 1 1 1 1 I 1- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ' " ' I M --1-t-r-1---r-r-f-t---1--t-r-r--1--1- 1--r-`'-1--t-r-r--t-r-1--r- -r-r-t-r - t r - t- - 214DNA060 - - 70 1 I 1 1 1 I I I I I 1 1 IIII I -I I I 1 1 I I 1 1 I I I I FX4DNF061 L 1 20.5 _J_1_LJ_-_L_I_1_1__J_1_L_I___L_LJ-1___I_1_L_L__1_LJ_1_ _I_J_L_L__ _L_I-1___`�_�_L_ I I 1 1 11 1 I I I 1 I I I 1 1 1 1 1 1 1 1 1 1 1 I 1 I I I 1 I I I I V --1-1--r-1---1"-1--1--t----1-T--r-I---r-r1-7- 1--r-r-r--T-r7-1-- -1-7-t_r -t-1--I--r---r-I-t-r- Q --I-+-1- ---4--I--f-+----I-+- -I---+-I--1- 1----1- F-4--I---+-1--1-+- -I--}--I a _J_1-LJ___L_LJ-1__J-1_L_I___1_LJ_1__J_J_L_L-_1_LJ_1_ _Li _L__1_L_I_. 214DNA048 _L_ Q 60 1 1 I 1 1 1 II 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I FB4CNP048L 1 17.6 C.) I I I I I I I 1 1 1 1 1 I I I I 1 1 1 1 1 1 1 1 1 1 1 I 1 --r-+-t--1---t-I--1-+---1-t-1--I---+-1--I-+---1--t-t-1---+-1--I-t I--1-+-I---+ -I-H----I-1-+-I-- (' -J-1-L_--__L-L-1--I---1-1- -I----1--1_�_1-_-1-.1-1-L--1_1__I_ _I_�_1-L- - -I--I-' _L_ Z 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1- 1 I I I I _ 1 -I 1 1 1_ 1 -1 I 1 I 214DNA042 _1 _ H - IIFI T 1 1 T I I 1 I T r1 T 1 1 r I - T r T- -T T T I I .FB4CNP042L _r- -1-t-r-1---r-r-[-t-- r--r-r-1---t-r-1-t---I--r-r-r--t -1- -1--r- -r--t r 2 50 I I 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I ' 1 I 1 1 1 ! I I I 14.6 J_1_L_I-__L_LJ_1__J_1_L_I___1_LJ_1__J_J._L_L_ _LJ_1_ . _J_1 __1_L_I--' L_ ❑ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I 214DNA036 1 w --1-T-r-I---r-r-r-T---1--r-r-1---r-r-i-7-77-7-r-r T-r-1 -I- r-r--T-r --F84CNP036L-r- --1-+-1--1---+--I--I-+---1-+-I--1---+-1---1-+- 1-4-1-- --+-1 -I-+-1---+ - -1-- _J_1_LJ___L_LJ_1__J_1_L_I___L_LJ_1__J_�._ _L__1 _LJ_1-L_ _L_I_1___LJ_1_L_ 1 1 I I I I 1 I I I I 1 I 1 1 1 1 I I I I 11 I W40 I 1 1 1 1 I - 1111 I 1 I II 1 I I I-- 214DNA030 -1 11.7 � --1-+-+--1---t ---1--r-+---1-t-1--1- -t-r--1-t- --r-t-I- -r -r---t-t r-- Z _--1-1--1---1--LJ-1---1----1--L--J--L-1 ---I-4-1- _ --I-1-I--- . -.FB4CNP030L-1-- 1 1 1 1 1 1 1 1 1 1 _ 1 -1 _ 1 - 1 1_ 1- 1 1 1 1 1 -1-1 r 1 I I _( I I -" I 1 + 1 T I I I -( 1 1 1 1 1 1 I 1- Iv ~ --1-t-r-I---r-r-1-t---1--t-r-1-- r7-t-- -1--r- - t-h--t-t--I- -1-- m 30 1 1 1 1 1 1 1 1 - 1 1 1 1 1 1 1 1 1 1 1 I 1 1 I 214DNA024 �_ 8.8 _J-1-LJ___L_LJ_1_-J_ _I__-1_ _ __1_ _I_J_1_L-_ _ FB4CNP030L_L- C/j 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 v> --1-T-r7---1--r-r-T- -7-r-1- -1--1-r- - -1- - - ---r-r--1--r---rl-T-r-- O --1-+-f--1----I -1- - ---I-+- - -+---I -+-1---+-1- 4---"-I-1-1-- J -J_1_LJ___ _1__J _LJ_l_ _1_1_1_L I _I JI_. 214DNA018 L- a 20 I I I I II I ow-- �- �- FB4CNP018L II5.9 W -J-t-i-----1-- -F-i--- -r i-t--- 1---t-t- - -r-t-+-I---1--1--I- I 1 1 1 -1- I --I-1--L-1- ---I -I---1--L __J__1-1--L-- --1-4- -1--1-1-L-- -1--1-4---L-1-1--L- _ I �j __ _ 1 _1_L_I_ I I I I _ 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 Z I t- j' 1 I 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 11 I I G 10 =-1- I -I-1-- -1-t-- I I I -r--1--1- - -r-r-I---t-1--1--t- -1--r-t-I---t-r-1-rt---r-r-t-r- 2.9 J_1-L _ _LJ_1__ ____L_LJ_1__J_1_L_L__1_LJ_1_ _I_1_1_L__1_LJ_1___LJ_1_L_ 5 I I I I I I I I I 1 1 1 1 1 I I 1 I I I lilt 1 1 1 I m -J-T-r --- --T---1-T-r-r--r-r7-T---I-7-r-r--T-1- BASED T-r- -+-+-1- ---1--f-J-+-----+-+--I---+-FJ-+---I---+-I---+-I--1 +-1-- _J_1_LJ___L_LJ_1__J_1_L_L__1_LJ_1___I_1_1__L--1_LJ_ AT 70.F(21.10C)AND AT RATED CFM 1_L_ 0 1 1 1 1 1 1 1 1 IIII 1 1 1 1 1 1 1 1 I 1 1 I I I I I I I ir- I I r 0.0 0 F -10.0 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 1 e i , i e , , e P 0� -23.3 -17.8 -12.2 -6.7 -1.1 4.4 10.0 15.6 21.1 26.7 OUTDOOR TEMPERATURE TESTED AIIRI COMBINATION RATINGS NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates,please refer to the AHRI directory www.ahridirectorv.org Additional ratings and system combinations can be accessed via the Bryant database at: www,MyBryantRatings.com For performance data at specific application&/or design conditions with various indoor unit combinations,the equipment performance calculator can be accessed at: http://rpmobbrv.wrightsoft.com/ High Tamp Low limp Model Number Indoor Coll Model Cooling EER SEER CapacityE COP HSPF CapH acity COP Number Capacity 21413NA018—A FB4CNP0181 17,800 11.7 14 17,800 9.72 8.2 10,400 2.40 2140NA024—A FB4CNP030L 22,200 11.5 14 22,200 9.84 8.2 13,200 2.54 2140NA030—A FB4CNP0301 28.800 11.7 14 28,600 9.82 8.2 17,100 2.44 214DNA036—B FB4CNP0301 33,000 11.7 14 93,800 9.622 8.2 21,000 2.40 2140NA042—A FB4CNP042L 40,000 11.5 14 41,000 9.62 8.2 25,200 2.50 2140NA048—A FB4CNP046L 46,000 11.7 14 45,500 9.84 8.2 27,800 2.56 2140NA060-A FX4DN(B,F)061L 57,000 11.7 14 54,500 3.70 8.2 33,000 2.56 " AHRI=Air Conditioning,Heating&Refrigeration Institute *Ratings are net values reflecting the effects of circulating fan heat.Supplemental electric heat Is not included.Ratings are based on: Cooling Standard:80°F(27°C)db 67°F(19°C)wb indoor entering air temperature and 95°F(35°C)db air entering outdoor unit. High—Temp Heating Standard:70°F(21°C)db indoor entering air temperature and 47°F(8°C)db 43°F(6°C)wb air entering outdoor unit. Low—Temp Heating Standard:70°F(21°C)db Indoor entering air temperature and 17°F(-8°C)db 15°F(-9°C)wb air entering outdoor unit. COP—Coefficient of Performance EER—Energy Efficiency Ratio HSPF—Heating Seasonal Performance Factor SEER—Seasonal Energy Efficiency Ratio 13 DETAILED COOLING CAPACITIES# EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES•FCC) 75(23.9) 85(29.4) 95(35) 105(40.0) 115(40.1) 125(51.7) EMI_ Capacity MBtuh TetiStem Capacity MBtuh total em Capacity MBluh Total em Capacity MBtuh TotalSYstern Capacity MBtuh Told Brion Capacity MBtuh Total CFM SYstall •FCC) Total Sena* Total Sant Kw• Total Sens* Total• Sens* Total Sala* Total Sens* KW** 214DNA018 Outdoor Section Witt FBACNP01111 Indoor Se-lion 72(222) 1.43 1044 1.20 20.38 0.08 1. v 19.27 9.88 1.54 18.10 _ 9.26 1.74 18.88 8.83 15.58 8.39 2.22 67(19.4) 19.44 12.77 1.19 18.48 12.39 ' 1.38 17.47 11,99 " 1.53 16.40 11.58 1.73 15.28 11.15 1.96 14.08 10.69 2.21 525 83(17.2)7* 17.99 12.27 1.19 17.10 11.90 1.35 16.16 ' 11.50 1.63 _ 15.16 11.00 - 1.79 _ 14.10 10.65 1.95 _ 12.98 10.19 2.20 62(16.7) 17.64 15.03 1.19 18.78 14.84 1.35 15.88 14.22 1.53 14.93 13.78 1.73 14.00 14.00 1.95 13.10 13.10 2.20 57(13.9) 16.97 16.97 1.19 16.30 16.30 1.35 15.58 15.58 1.52 14.51 14.81 1.73 13.98 13.98 1.95 13.08 13.08 2.20 72(22.2) 21.88 10.96 1.21 20.77 10.58 1.38 19.62 ' 10.18 1.58 18.40 9.76 1.76 17.12 9.33 1.98 15.77 8.88 2.23 87(19A) 19.86 13.61 1.20 18.88 13.22 ' 1.37 17.80 12.82 1.55 16.69 12.39 1.75 15.51 11.95 1.97 14.27 11,48 2.22 000 63(17.2)tt 18.40 13.06 1.20 17.47 12.87 1.36 16,49 ' 12.27 _ 1.54 15.44 11.84 1.74 14.34 11.39 _ 1.97 13.19 10.92 2.21 62(16.7) 18.08 16.13 1.20 17.20 15.71 - 1.36 18.27 18.27 1.54 15.43 15.43 1.74 14.54 14.54 1.97 13.59 13.59 2.22 57(13.9) 17.73 17.73 1.20 17.01 17.01 1.36 16.24 18.24 1.54 15.41 16.41 1.74 14.52 14.52 1.97 _ 13.57 13.57 2.22 72(222) 22.22 11.46 1.22 21.08 11.07 1.39 19.88 10.88 1.57 18.83 10.24 1.77 17.31 9.80 2.00 15.92 9.35 2.25 87(19A) 20.19 14.41 1.22 19.15 14,01 1.38 18.06 13.60 + 1.56 16.91 13.18 1.76 _ 15.70 12.71 1,99 14.44 12.22 2.23 575 63(17.2)11 18.71 13.81 1.21 17.75 13.41 1.38 16.74 12.99 1.58 15.66 12.55 _ 1.75 14.53 12.09 1.98 13.35 11,59 2.23 82(16.7) 18.48 17.11 1.21 17.83 17.83 138 18.80 ' 16.80 1.56 15.93 15.93 1.76 14.99 14.99 1,98 13,99 13.99 2.23 57(13.9) 18.36 18.36 1.21 17.60 17.60 1.38 16.78 18.78 1.58 15.91 15.91 1.75 14.97 14.97 1.93 13.97 13.97 2.23 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES•F(•C) 75(23.9) 55(29A) 95(35) 105(40.5) 115(46.1)_ 120(51.7) CFI, ET88 Capacity MBtuh TMd Capacity MBWh SYStIlin Total Capacity MBtuh BYellm Total Capacity MBtuh Total Capacity MBhSt SYstem Total Capacity MBtuh Total Total Sena* KW,* Total Sala* K Total Sent KKW• Total Sent KM/* Total Sena* Total Sens* K T,4CNp02-1 Cut door Section With FB-CNP03 IL r udoor Section 72(222) 2247 13.51 1.53 _ 2528 13.08 1.71 24.03 12.62 1,91 22.72 12.15 2.14 21.30 _ 11.55 2,41 19.77 11.11 2.72 67(19.4) 24.06 18.88 153 22.98 18.24 171 21.82 15.76 1.91 20.62 15.31 2.15 19.39 14.80 2,42 17.93 14,25 2.72 700 83(17.2)11 22.32 16.04 153 21.30 15.60 1.72 2023 15.14 1.92 19.11 14.68 2.16 17.91 14.15 2.42 18.82 13.80 2.73 62(16.7) 21.92 19.75 1.53 2094 19.28 1.72 1923 16,78 192 18.88 18.78 2.10 17.88 17.88 2.42 18,93 18.113 2.73 57(139) 21.31 21.31 1.54 20.52 20.52 1.72 19.70 19,70 1.92 18.81 18.81 2.18 1796 17.86 2.42 1631 16.81 2.73 �., 72(222) 2697 1420 1.55 25.73 13.75 1.72 24.44 13.30 1.92 23.07 12.82 ' 2.16 21.60 12.31 2.43 20.01 11.76 2.74 67(19.41 24.53 17.79 1.55 23.38 17.34 1.73 22.20 18.87 1.93 20.95 1638 2.16 19.81 15.88 2.43 18.18 1529 2,74 800 83(172)tt 22.77 17.07 1.55 21.70 18.62 1.73 20.80 16.15 1.94 19.43 15.85 2.17 18.19 15.13 2.44 16.86 14.56 2.75 62(16,7) 22.45 21.17 1.55 21.45 21.27 1.73 20.50 20.50 194 1955 19.55 2.17 15.53 16.53 244 17.41 17.41 2.74 67(13.9) 2220 2220 1.55 - 2135 2135 1.73 2047 20.47 1.94 19.53 19.53 2.17 18.61 1851 2.44 17.39 1739 2.74 72(222) 2735 14.88 1.56 26.08 14.41 1.74 24.73 13,94 1.94 2333 13.46 2.17 21.82 12,94 2.44 20.16 12.38 2.75 57(19.4) 24.89 1825 157 23.71 18.38 115 22.49 17.91 1,95 2120 17.40 2.18 19.84 18.86 2.45 18.37 1628 2.76 900 83(172)tt 23.12 18.05 1.57 22,02 17.59 1.75 - 20.88 17.10 1.96 19.58 16.59 2.19 18.41 _ 18.05 2.48 17.05 15.45 2.77 62(18.7) 22.97 22.97 157 22,08 2208 1.75 21.14 21.14 1,95 20.14 20.14 2.19 19.07 19.07 2.45 17.88 17.88 2.78 57(13.9) 22.94 22.94 1.57 22.05 22.05 1.75 21.11 21.11 1.95 20.12 20.12 2.19 19.04 19.04 2.45 17,86 17.86 2.76 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES•F C C) 75(239) _ 85(29.4) 95(35) 106(40.6) 115(48.1) 125(51.7) EV219 Capacity MBtuh Total Capacity MBtuh Total CapacityMBtuh Total Capacity MBtuhBtuh Total Capacity M Total Capacity MStuh Tot CFM al•FSentC) Total Set Total Sens* Sy tam Total Swett K91 en Total Swat n Total Set Kyy.m• Total Sent 2t40NA030 Outdoor Section WItt FB4CNP030L Indoor Secion 72(22. 33.97 17.32 1.97 32.47 16.75 .17 30.87 ' 16.16 2.40 29.15 15.54 _ 2.67 _ 27.30 14.87 2.813 25.29 14.15 3.33 67(19.4) 30.80 21.30 1.97 29.42 " 20.72 2.17 27.96 20.13 2.40 28.39 19.50 2.67 _ 24.E 18.82 2.98 22.86 18.10 3,32 875 83(17.2)11 28.51 20.48 1.97 27.22 19.89 _ 2.17 25.86 19.29 2.41 24.39 18,68 2.67 22.82 17.98 2.97 21.12 1725 3.32 62(18.7) 27.99 25.15 1.97 26.74 24.55 2.17 25.44 2390 2.41 24.07 23.17 2.87 22.67 22,67 2.97 21.30 21.30 3.32 57(13.9) 27.05 27.05 1.97 28.08 26.06 2.18 25.01 25.01 2.41 23.88 23.58 2.87 22.84 22.64 2.97 21.27 21.27 3.32 72(22.2) 34.85 18.48 2.00 33.25 17.90 _ 2.21 31.57 1730 2.44 29.78 18.88 2.71 27.81 15.97 3.02 25.71 15.24 337 67(19.4) 31.61 23.17 2.01 30.15 22.59 221 28.60 _ 2197 2.44 28.95 21.32 2.71 26,18 20.81 3.02 23.27 19.84 3.36 1050 83(17.2)1f 29.28 22.21 2.01 - 27.91 21.82 ' 2.21 28.47 21.00 2.45 24.94 20.34 2.71 23.29 _ 19.83 3.01 21.52 18.86 3.38 132(18.7) 28.88 27.53 2.01 27.62 27.37 2.21 2638 26.36 245 25,12 25.12 2.71 23.77 _ 23.77 3.01 22.28 22.28 3.36 57(13.9) 28.55 28.55 2.01 27.48 27.48 2.21 26.33 26.33 2.45 26.09 25.09 2.71 23,74 23.74 3.01 22.28 22.26 3.36 72(22.2) 35.15 18.97 2,02 39.53 18.39 2.23 31.81 17.78 2.48 _ 29.98 ' 17.13 2.73 27.99 l 1644 393 25.85 15.70 3.38 87(19.4) 31.89 23.98 2.02 30.39 23.37 2.23 28.82 22.74 2.45 27.14 22.07 2.73 26,34 2135 3.03 23.41 20.58 3.38 1125 83(17.2)1' 29.55 22.94 2.03 28.15 22.34 2.23 26.69 21.71 2.48 25.12 21.03 2.73 23.45 20.30 3.03 21.88 19.51 3.38 ' 52(16.7) 29,18 29.18 2.03 28.02 28.02 2.23 26.83 28.83 2.46 25.55 25.55 2.73 _ 24.15 24.16 3.03 22,63 22.63 3.38 57(13.9) 29.10 29.10 2.03 27.98 2796 2.23 26.80 26.80 2.48 26.52 25.52 2.79 24.13 24.13 3.03 22.00 22,00 338 -bee notes on page 16 DETAILED COOLING CAPACIII'IES#CONTINUED EVAPORATOR AlR CONDENSER ENTERING AIR TEMPERATURES°F CC) 75(23.9) 85(29A) 95(35) 105(40.6) 115(46.1) 125(51.7) CFM EYYB Capacity MSWh 7bta1SWAM Capacity MDtah TotalDraw Capalsly MBtuh Total Capacity MBtuh TOWSleet Capacity MBtuh Total Capacity MOM, Total •F(*C) Total Sant KW" Wall Banat KW"• Total Sena* KW" Total Sense KW** Total Sant KW" SAM Sent Rylr.. .I IONARUJ Gu:dno,Ssctlon Vlir',FB4CNP00iL Indoor S,.r.Yion 1 r ,�1 L. I t.:i . 1 . I 67(19.4) 35.87 25.19 2.24 34.23 24.50 2.50 32.48 23.78 2.78 30.59 23.01 3.09 28.52 22.17 3.44 28.33 2129 3.84 1050 63(17.2)17 33.28 24.23 2.25 31.75 23.54 2.50 30.14 22.82 2.77 28.38 22.05 3.08 28.45 21.21 3.43 24.41 20.32 3.84 62(18.7) 32.68 29.85 2.25 31.22 29.12 2.50 29,9! 28.32 2.77 28.03 2/.40 3,08 25.31 26.31 3.43 24.65 24.65 3.84 5e(13.9) 91.53 31.83 2.26 30.46 90.48 2.50 29211 29.20 2.// 27.82 27.02 3.08 28.28 25.28 3.43 24.52 24.62 3.84 72 223 40.13 21.34 2.2! 38.A 2U.53 2.54 36.25 19.90 2.83- 34.10 19.12 3.14 31.76 -/' 6719.4) 35.53 213.7/ 2.28 34.82 25.07 2.54 39.09 25.34 2.if2 31.03 24.64 3.13 2--- 23.87 3.49 26.8�'�.75-j1.1 '3.W 1200 83(17.2)1'7 33.92 25.70 2.29 32.33 - 25.00 2.b4 ' 30.84 24.26 2.62 28.81 23.4/ 9.13 26.81 22.59 3.48 24.71 21.68 3.88 62(15.7) 33.39 31.85 2.29 31.E-- 31.112 2.54 30.31 - 30.31 2.62 - 28.80 28.80 3.12 2/.16 . 27.18 ' 3.48 25.40 25.40 3.138 51(13.9) 32.83 32.83 2.29 31.58 31.58 2.54 - 34).24 30.24 2.82 26.// 28.// 3.12 27.13 27.13 3.48 25.3/ 25.37 3,58 72(22.2) 40.68 22.25 2.31 38.72 21.53 2.58 30.00 211.80 2.9 34.45 20.81 3.19 82.03 19.15 3.54 29.50 18.25 3.94 87(19.4) 37.04 28.29 2.32 35.25 27.57 " 2.58 33:1/ 26.81 2.86 31.35 ' 25.98 ' 3.17 29.14 25.07 3.53 28.55 24.10 3.93 1350 53(17.2)11 34.40 2/.11 233 32./b 25.38 2.58 31.00 25.62 2.68 29.12 24./9 3.1! 27.07 ' 23.87 ' 3.52 24.93 22.89 3.92 62(16.7) 33.95 33.95 2.33 32.55 32.55 2.58 91.13 ' 31.13 2.85 29.57 29.57 3.17 27.85 27.85 3.52 ' 28.00 28.00 3.93 57(13.9) 39.84 33.84 2.33 32.51 32.51 2.58 31.TO 31.10 _ 228 29.54 2934 3.1/ 27.82 27.82 852 25.98 25.98 3.93 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES•F CC) 75(23A) 85(29A) 96(35) 106(40.6) 115(46.1) 125(51.7) CFM EYVB COY MBtuh TotaWan Capacity M134a1 Total SY a Capacity MBloh TotalCapacity MSluh TotalSY6 Capacity M IMI TotalSYstem Capacity MBtuh Total Wiest °FCC) Total Sens* KW" Tblai Sort KW** Metal Sense KW" Total Sent KW" Total Same KW** Total Sens* K • uoN,..9 L'Oaldou Secrio'r Wit 1 FB.IC1.1P042L Indoor SEKLori 72(22.2) 48.18 24.31 2.78 46.14 23.54 _ 3.12 43.91 22.72 3.47 41.39 21.79 3.89 38.48 20.75 4.38 35.14 19.57 4.98 67(19.4) 43.90 29.85 2.81 42.03 29.07 3.13 _ 40.00 2824 3.48 37.70 27.31 3.88 35.04 26.26 4.38 31.96 25.05 5.00 1225 83(172)1f , 40.78 28.78 2.83 39.02 _ 27.98 3.14 37.15 27.15 3.48 35.01 28.22 3.58 32.54 25.18 4.38 29.88 23.95 5.01 62(18.7) 40.02 35.22 2.83 38.32 34.41 3.14 36.51 33.54 3.48 34.48 32.52 9.88 32.15 32.15 4.35 29.82 29.82 5.01 57(13.9) 38.47 38.47 2.84 37.12 97.12 3.14 35.68 35.66 3.48 34.03 34.03 9.88 32.08 32.08 4.38 29.78 29.78 5.01 72(22.2) 49.11 25.48 2.81 45.98 24.70 9.15 44.84 23.85 3.51 42.03 22.91 9.92 39.00 21.85 4,41 35.57 20.88 5.02 67(19.4) 44.77 31.73 2.84 42.82 30.94 3.17 4030 _ 30.10 3.51 38.30 29.14 3.92 35.55 28.08 4.42 32.39 26.81 5.03 1400 89(17.2)11 41.89 30.52 2.86 39.80 29.72 3.17 37.83 28.87 3.52 35.61 27.92 9.92 33.04 28.83 _ 4,42 30,10 25.53 5.04 82(16.7) 40.95 37.70 2.86 39.20 38.82 3.18 37.36 35.82 3.62 _ 35.36 35.38 3.92 33.27 33.27 4.42 30.32 30.82 5.04 57(13.9) 40.07 40.07 2.67 38.63 38.83 3.18 37.09 37.09 3.52 35.31 35.31 3.92 33.23 33.23 4.42 30.78 30.78 5.04 72(22.2) 49.81 28.57 2.84 47.60 25.78 3.16 45.20 24.93 3.54 42.49 23.97 3.96 39.38 22.90 4.44 35.88 21.70 5.05 67(19.4) 46,44 33.53 2.87 43.41 32.72 3.20 41.22 31.135 3.55 38.75 30.88 3.96 35.92 29.75 4.45 32.71 28.46 5.06 1575 63(17.2)11 42.28 32.19 2.89 _ 40.38 31.38 _ 3.21 38.36 30.51 3.55 38.06 29.59 3.96 33.43 28.40 4.45 30.42 27.09 5.08 62(18.7) 41.78 39.89 2.89 39.97 39.97 3.21 38.30 38.30 3.55 38.41 36.41 3.96 34.21 34.21 4.45 31.84 31.64 5.07 57(18.9) 41.40 41.40 2.90 39.89 39.89 3.21 38.25 38.25 - 3.55 36.36 36.36 3.98 34.17 34.17 4.45 31.80 31.80 5.07 EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES•P re) 75(23.9) 85(29.4) 95(35) 105(40.8� 115(46.1) 126(51.7) CFM EWE Capacity MB1uh Total Capacity MBtah Total Capacity MBtuh Total tem gP�KY MBtuh Total Capacity MINIMTotalSYttem Capacity MStuh lOtal •FCC) Taal Sens* nSyst Total Sens* SKEW* Total Sens* SKEW** 'Mal Sens KW.* Total Sena* KW" TotalSens* KW.* 214DNA048 Outdoo SoclIon With FB4CNPn43L Indoor Section 72(222) 55.75 28.05 3.23 5927 27.12 3.59 50.55 28.11 3.96 47.48 _ 24.99 4.37 44.01 23.75 4.83 40.13 22.38 5.35 87(19.4) 50.68 34.45 3.22 48.45 33.53 3.57 46.00 32.52 _ 9.99 43.29 31.42 4.34 40.10 30.17 4.80 38.59 28,79 5.33 1400 63(17.2)ff 48.99 33.15 3.22 44.92 32.23 _ 3.55 42.87 31.23 3.91 40.12 30.14 4.31 97.25 28.91 4.78 34.00 27.52 5.32 62(18.7) 48.10 40.66 3.21 44.11 99.89 3.55 41.94 38.63 3.91 39.54 37.40 4.31 36.87 36.87 4.77 3421 34.21 5.32 57(13.9) 44.33 44.33 3.21 42.75 42.75 3.54 41.05 41.05 3.90 39.07 39.07 4.30 38.80 38.80 _ 4.77 34.17 34.17 5.32 72(22.2) 56.80 29.37 3.28 54.22 25.42 3.64 51.35 27.39 4.01 _ 48.15 26.25 4.42 44.55 24.98 4.88 40.58 23.80 5.40 87(19.4) 51.88 38.59 3.28 49.35 35.66 3.82 46.77 34.62 _ 3.99 43.87 _ 33.48 4.39 _ 40.84 _ 32.20 4,85 37.01 30.78 5.38 1600 83(172)11 47.95 35.15 3.27 45.79 34.21 3.61 43.42 33.18 _ 3.96 40.77 _ 32.08 4.37 37.78 30.79 4.83 34.43 29.35 5.37 62(18.7) 47.16 43.44 3.27 45.10 42.39 3.80 42.90 41.17 3.96 40.54 40.54 4.37 38.10 38.10 4.83 35.30 35.30 5.38 57(13.9) 46.14 48.14 3.26 44.46 44.46 3.80 42.61 42.61 3.96 40.49 40.49 4.37 38.06 38.06 4.83 35.26 35.25 5.37 72(22.2) 57.65 30.85 3.33 54.95 29.88 3.89 52.00 28.84 4.06 48.67 27.48 4.47 44.97 26.19 4.93 40.88 24.79 5.45 67(19.4) 52.48 38.69 3.33 50.04 37.72 _ 3.67 47.37 36.85 4.04 44.38 35.48 4.45 41.04 34.15 4.91 37.34 32.64 5.44 1800 63(17.2)1-1 48.72 37.10 3.32 46.47 36.13 3.68 44.02 35.07 4.02 41.28 33.91 4.42 98.20 32.58 4.88 34.78 31.07 5.42 82(18.7) 48.09 46.92 3.32 45.99 45.99 3.66 43.96 _ 43.96 4.02 41.71 41.71 4.43 39.13 39.13 4.89 38.17 36.17 5.43 57(13.9) 47.25 47.65 3.32 45.88 45.88 3.68 43.91 43.91 4.02 41.66 41.86 4.43 39.09 39.09 4.89 38.13 36.13 5.43 See notes on page 16 DETAILED COOLING CAPACTI'IES#CONTINUED EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES°F(°C) 75(23.9) 85(294 _ 95(35) 106(40.8) 115(46.1) 125(51.7) CFM EWB Capacity MBtuh Total Capacity MBIuh Total Capacity MBtuh Toth Capacity MBluh TotalSystem Capacity MBtuh Total Capacity MBIuh Total °FrC) Total Faust KW** Total Swaat KW" Total swat KW** Total Swat Kw** Total Sang# KW** Total Swat KW** IDNArGa Olatloor Sect10r With Fr'IDNIB.F106 I L Indoor Section 72(22.2) 64.47 36.36 3.53 61.89 35.21 3.88 58.75 34.01 _ 4.30 55.61 32.74 4.78 52.113 31.38 5.34 48.43 29.90 5.99 67(19.4) 58.78 44.97 3.50 58.25 43.82 3.86 53.58 42.82 427 50.71 41.34 _ 4.78 47.58 39.96 5.32 44.10 98.44 5.98 1750 63(17.2)tt 54.80 43.31 3.48 52.27 42.18 3.84 49.79 40.96 ' 4.25 47.13 39.88 4.74 44.21 38.28 5.29 40.98 38.76 5.94 62(16.7) 53.59 53.34 3.48 51.34 _ 52.14 3.84 48.98 50.87 4.25 48.43 49.42 4.73 43.81 43.81 529 41.19 41.19 5.94 57(13.9) 51.87 51.87 3.47 50.08 50.08 3.83 48.17 _ 48.17 425 48.08 _ 48.08 4.73 49.74 43.74 5.29 41.14 41.14 5.94 72(22.2) 85.81 38.13 3.59 82.71 38.85 ' 3.96 59.68 35.74 4.37 56.39 34.44 4.85 52.83 33.04 5.41 48.97 31.55 8.06 67(19.4) 59.88 47.88 3.57 57.21 46.69 3.92 54.43 45.47 4.34 51.45 44.18 4.82 48.19 42.72 5.38 44.64 41.17 8.03 2000 83(17.2)tt 55.86 46.01 3.55 53.22 44.83 3.91 50.64 43.61 4.32 _ 47.87 42.29 4.80 44.85 40.88 5.36 41.52 39.29 6.01 62(18.7) 54.79 57.14 3.55 52.47 55.78 3.90 50.08 50.08 4.32 47.80 47.60 4.80 45.32 45.32 5.36 42.64 42.54 8.02 57(13.9) 53.97 53.97 3.54 52.05 _ 52.05 3.90 49.99 49.99 4.32 47.74 _ 47.74 4.80 _ 45.26 45.26 5.36 _ 42.49 42.4E 6.02 72(22.2) 66.47 30.80 3.66 83.48 38.81 4.02 60.32 37.97 4.43 66.90 38.06 4.91 53.30 34.64 5.47 49.33 33.13 8.12 67(19.4) 60.87 50.85 3.63 57.94 49.44 3.99 55.07 48.18 4.40 51.99 48.83 4.89 48.87 45.37 5.45 45.03 43.74 8.09 2250 63(17.2)41 58.48 48.58 3.61 53.93 47.98 3.97 51.26 48.11 4.38 48.41 44.78 4.87 45.32 43.28 5.43 - 41.91 41.63 8.07 62(16.7) 55.83 55.83 3.61 53.75 53.75 3.97 51.56 51.56 4.39 49.17 49.17 4.87 48.57 48.57 544 ' 43.83 43.83 8.09 57(13.9) 55.71 55.71 3.61 53.68 1 53.68 3.97 51.49 51.49 4.39 49.12 49.12 4.87 48.49 48.49 5.43 ` 43.58 43.58 8.09 t Total and sensible capacities are net capacities.Blower motor heat has been subtracted. t Sensible capacities shown are based on 80°F(27°C)entering eV at the Indoor coll.For sensible capacities at other than 80°F(27°C),deduct 835 Btuh (245 kW)per 1000 CFM(480 US)of Indoor coil air for each degree below 80°F(27°C),or add 835 Btuh(245 kW)per 1000 CFM(480 US)of indoor coil air per degree above 80°F(27°C). #Detailed cooling capacities are based on Indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008.II additional tubing length and/or Indoor unit Is located above outdoor unit,a slight variation In capacity may occur. *'Sys.kw le total of Indoor and outdoor unit kilowatts. tt At TVA rating Indoor condition(75°F edb/63°F ewb).All other indoor air temperatures are at 80°F edb. NOTE:When the required data falls between the published data,interpolation may be pedonned.Extrapolation Is not an acceptable practice. EWB-Entering Wet Bulb 0+ at HEAT PUMP HEATING PERFORMANCE INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES•F PC) d(19A) 7(•13.9) 17(-23) 27(-2.M) 37(2.5) 47(93) 57(13.9) 67(19.4) Cpse117 MINIMTUE7l To191 UN 1bY TI 1 TOW N 19161 Total dploR7 M94eh gy9. C4pa6R7 MSh1h sKy. 6AB CapeCapacityheeKy. Commas M&W7 g),4. dpxlry MBE* dpaaly MSWh 8Y+- pa so_ Cacity M881h g1,4. EDS CFM °Fcc) M1a1 Inbp Kw Total Intel; Kw total IMP Kw Total leap Kww 1bW Meg ban Kw Total M19p Kw UP rotas Kw Total Inlep KW 214DNAUIF Outdoor Secliun WB%t F64CNPiISL Indoo Section 525 5.26 4.54 1.09 7A5 6.84 1.09 9.80 894 1.14 1254 11.14 _ 1.21 15.07 13.71 127 1797 17.87 1.35 21.00 21.00 1.44 24.19 24.19 1.53 ea 600 5.36 4.93 1.04 7.57 625 1.09 9.96 9.08 1.13 12.70 1128 1.19 1526 13,89 124 18.13 15.13 1.31 2135 2135 1.40 24.32 24.32 1A7 675 5.44 5.01 1.04 7.86 7.04 1.09 10.09 920 1.13 12.83 11 A0 1.19 15.49 14.04 1.23 18.33 18.33 129 21.54 2154 1.37 24.32 24.32 1.43 525 4.98 458 1.08 7.15 6.57 _ 1.14 9.49 8.85 1.20 1228 1090 127 14.78 13.45 193 17.54 1754 1.41 20.61 20.61 1S1 23.84 23.84 1.81 70 600 5.09 4.67 1.08 727 6.68 1.14 9.64 8.79 1.19 _ 12A5 11.05 125 _1498 13.63 121 17.80 1790 1.38 20.95 20.95 1.47 24.01 24.01 1,55 675 5.16 4.75 1.09 7.38 _ 8.78 1.14 9.77 8.91 _ 1.18 12.58 11.17 124 15.14 _ 19.78 _ 1.29 18.01 18.01 1.38 2121 21.21 1.44 24.05 2425 1.50 525 4.65 428 1.13 699 627 1.19 9.15 6.35 125 11.98 10.64_ 1,33 14A9 13.19 1A0 1721 _ 1721 1A8 2022 20.22 1.58 23A7 23A7 1.89 75 600 4.74 4.38 1.19 895 639 1.19 9.31 8.49 124 12.18 10.80 1.31 14.89 13.37 1.37 17.46 17.48 1.45 20.55 2055 1.54 23.68 23.68 1.62 575 4.84 4.45 1.14 7.05 8.48 1.19 9.44 8.61 1.24 12.30 10.93 1.30 14.88 19.62 1.36 17.87 17.87 1A2 2032 20.82 1.51 23.75 23.75 1.58 214DNA(124 Outdoor Section Wd0 FBICNP(-JCL Ir[h,o Sv,... 700 8.09 745 1.53 1051 9.85 159 1325 12.08 1,65 18.10 14.30 1.71 18.99 1728 _ 1.79 2227 22.27 1,88 26.02 26.02 1.98 2955 29.55 2.06 65 800 823 7.67 1.54 10.66 9.80 158 19.83 12A3 1.84 18.28 14.46 1.70 _ 1922 17,49 1.76 22.55 22.55 1.64 28.19 28.19 1.92 29.49 29.49 2.00 900 8.35 7.89 1.54 10.81 993 1.59 13.78 1266 1.64 , 18.44 14.60 1.69 19.41 17.87 1.74 22.78 22.78 1.82 2620 2620 1.89 29.26 2926 1.95 700 7.89 7.08 1.60 10.12 9.30 1.66 12.77 11.64 1.72 15.81 14.04 1.80 18.67 _ 1699 1.87 21.95 21.95 1.96 25.62 _ 25.62 2.08 2923 29.23 218 70 800 7.84 721 1.60 _ 1029 9A5 1.85 1299 1124 1.71 15.99 14.20 1.78 18.89 17.19 1.84 2220 22.20 1.93 25.86 25.88 2.02 29.23 29.23 2.10 900 7.98 732 1.61 10.43 9.59 1.66 1321 12.05 _ 1.71 18.16 1435 1,77 19.08 17.37 1.83 22.42 22.42 191 25.98 25.98 1.98 29.10 29.10 205 700 7.30 6.71 1.87 9.74 895 1.73 12.37 1129 1.60 15.54 13.80 1.88 1837 16.72 1.96 21.80 21.80 2.06 25.21 25.21 2.111 28.90 28.90 226 75 800 7.44 694 1.87 9.90 9.10 1.73 12.57 11.46 _ 1.79 15.73 1397 _ 1.88 1858 1691 1.93 21.88 _21.8e 2.02 25.53 25.53 2.12 28.93 28.93 220 900 7.55 895 198 10.03 922 1.73 12.73 11.81 1.79 15.88 14.10 1.85 18.76 17.07 1.92 22.08 22.08 2.00 25.65 2598 2.08 28.88 28.88 2.15 2 4DNAO30 Outdoor 5cC1,nn Walk F84CNP430L Indoor Section 875 _ 1054 9.70 190 13.55 12.45 1137 17.16 15.84 _ 1.95 20.49 18.19 2.04 24.30 22.12 2.14 28.57 28.57 228 33.42 33.42 2A0 37.91 37.91 2.51 65 1050 10.81 9.96 1.81 13.87 12.75 1.88 17.44 15.90 1.95 _20.83 18,50 2.02 24.73 2250 2.11 29.10 29.10 222 33.84 33.84 2.34 37.90 37.90 2A3 F,, 1125 1091 10.04 1.82 13.99 12.86 1,88 1754 _ 15.99 1.95 20.96 18.61 202 24.68 _22.64 2.11 29.28 2928 222 33.88 33.88 2.32 37.80 37.80 2A1 J 875 10.08 927 1.87 13.10 12.04 1.95 16.82 1534 2.04 20.13 17.138 213 23.89 21.74 229 28.09 28.09 2.35 32.88 32.88 250 97.48 37.48 2.62 70 1050 10.34 9.51 1.89 13.40 12.31 1.96 17.12 15.61 2.03 20.47 18.18 211 24.31 22.12 220 2650 28.80 2.91 33.42 33.42 2A4 37.51 3751 2.53 1125 10.44 9.80 1.90 13.51 12.42 198 17.23 15.71 2.04 _ 20.59 1829 _ 2.11 _ 24.46 2226 220 28.79 28.79 2.31 33.53 33.53 2.42 0.00 0.00 0.00 875 951 8.84 195 12.64 11.62 2.02 16.08 14.68 2.11 19.78 17.57 222 23.48 21.37 2.32 27.82 27.62 2.45 32.34 3234 2.60 37.01 37.01 2.79 75 1050 9.86 9.07 196 12.94 11.89 2.03 18.76 1528 2.12 20.11 17.88 220 _23.69 21.74 2.30 28.11 28.11 2.41 32,93 32.93 2.54 37.11 37.11 2.84 1125 9.95 9.16 197 13.05 1199 2.04 16.87 1639 2.12 20.23 17.97 2.20 , 2404 21,88 229 28.30 2830 2A0 33.08 33.08 252 37.07 37.07 2.62 1-1❑rlA03.;Outdoor Seaton{:i0 F8.1CNP135L Indao Section 1050 12.92 11.69 2.18 16.60 15.18 228 20.40 18.60 2.34 2490 _ 22.12 245 29.12 2850 2.55 33.86 3398 2.68 39.26 39.25 2.81 45.49 45A9 3.02 65 1200 13.19 12.13 220 16.81 15.44 227 20.77 18.94 2.36 2523 _ 22.40 _2.44 29A9 25.84 2.53 _ 3432 _3432 2.69 39.87 39.87 2.76 4623 48.23 2.94 1350 13A3 1235 2.23 17.08 1559 229 21.13 1927 238 2551 22.66 2.44 29.82 27.14 2.52 34.70 34.70 2.61 40.38 4038 2.74 46.70 48.70 2.88 1050 12,30 11.32 226 1591 14.622 224 19.81 18.06 _ 2A3 2451 21.77 2.55 _ 28.67 28.09 2.65 3335 33.35 2.77 38.80 38.60 2.99 44.71 44.71 3.15 70 1200 1258 11.56 228 18.22 14.90 238 20.15 18.38 2.44 24.82 22.05 2.54 _29.04 28.43 2.83 33.80 33.80 2.74 99.20 39.20 2.813 45.47 45A7 3.07 1350 1220 11.77 231 16.48 _ 16.15 , 2.38 20.47 18.66 2.45 25.10 2229 2.55 29.38 _ 26.72 2.83 34.19 34.19 2.72 39.70 39.70 2.85 46.01 48.01 3.02 1050 11.66 10.73 2.35 15.90 14.08 2.49 1920 1750 253 24.07 _21.37 2.86 2823 25.89 2.77 32.83 _ 32.83 _ 2.89 37.95 37.95 3.06 4392 43.92 329 76 1200 11.92 1097 2.37 15.80 14.34 2.45 19.54 17.82 2.63 24A1 21.68 256 28.80 28.02 2.75 3328 _ 3328 2,85 98.54 38.54 _ 3.00 44.68 44.88 322 1350 12.15 11.18 2.40 15.87 14.58 2A7 19.85 16.10 2.55 24.89 21.93 2.65 28.91 2831 2.74 33.66 33.68 2.94 39.03 39.03 2.98 4528 45.28 9.16 6 See notes on page 18 HEAT PUMP HEATING PERFORMANCE CONTINUED INDOOR AIR OUTO0OR COIL ENTERING AIR TEMPERATIBIES•F re) -3(19A) 7(-13.9) 17(4.3) 27(-218) _ Total (2.8) _ 47(6 3) 57(13.9) 87(19.4) • 70 Total Togl Total 70W TOW Tbtel Tohl EDO Capacity MEWSsys_ Casualty MBtuh 9Ye- Capoolty MEath sr,. CePaaay MEWe BY► Cepedty MRWhsys_ Capacity MEMM sys_ Clanks MaM sys_ Camay MEtuh 'F(•C) CFM EMS hasp tem TOtaI Into; Mn 18 I htta9 tem Total Intag tem 15151 Gm tam tam tam Kw Told Kw KW hasp Kw Total !Meg Kw Thiel hop Kw Total Oleg Ky 211ONA042 Outdoor Secliun Will FSSCNP(42L Indoa Section 1225 15.59 14.35 2,48 19.93 18.31 259 24.83 22.64 2.71 3026 26.88 2.87 35.68 32.45 3.01 _4158 41.58 3.18 48.02 48.02 3.34 53.69 53.89 3.47 65 1400 1591 14.84 2.50 2028 18.64 259 25.75 23A8 2.72 30.60 27.17 2.84 38.05 32.81 2.98 42.10 4210 3.14 4521 48.21 326 53.51 53.51 3.37 1575 18.19 14.89 251 20.58 18.91 2.80 26.05 23.75 _ 2.72 30.91 2748 2.84 36.39 33.12 2.98 _ 42.45 42.45 3.10 48.18 48.18 320 5324 5324 3.31 1225 14.78 13.50 2.58 1920 1734 2.89 24.06 2153 2.82 29.80 26.47 299 35.19 32.02 3.14 41.00 41.00 3.32 47.42 47.42 3.48 53.09 53.09 3.52 70 1400 15.07 13.87 2.59 19.52 17.94 2.69 24.44 2228 2.81 30.13 26.78 2.96 35.55 32.35 3.10 41A9 41.49 327 47.70 47.70 3.40 5299 52.99 3.52 1575 15.33 14.10 2.61 19.82 18.21 2.71 24.79 22.80 2.52 30.42 27.02 295 35.89 32.88 3.02 _ 41.91 41.91 324 47.75 47.75 3.35 52.74 52.74 3.45 1225 14.00 12.88 2.68 18,60 17.00 2.79 23.38 21.32 _ 2.93 29.35 _ 28.07 3.11 34.70 _3157 328 40.41 40.41 347 46.83 46 7 39 3.84 52A7 52.47 3.79 75 1400 1427 13.13 289 1850 1728 290 23.74 21.85 2.92 29.38 26.38 3.09 35.07 3192 3.24 40.89 40.59 _ 3.41 47,79 47.13 355 52.43 • 52.43 3.68 1575 1451 13.34 2.71 19.07 17.53 2.81 24.05 21.93 2.93 29.95 28.80 3.07 35.39 3220 321 4130 41.30 3.38 4728 4728 3.50 62.23 5223 9.60 aI.IDNAOiE Ouhlnu'Svection vats F©.FCNPl 44L IF o,.n...- 1400 16.35 15.04 2.75 21 A0 19.68 2.87 28.82 24.46 3.00 33.50 29.76 3.17 3920 35.87 _ 9.31 45.88 _ 45.68 3.48 53,38 53.36 3.67 81.87 81.87 3.84 65 1800 16,69 1538 2.78 21.78 20.01 2.89 2725 24.85 3.00 33.88 30.09 3.18 _ 39.87 313.10 _ 329 4828 4826 3.44 54,19 54.19 3.61 62.42 82A2 3.78 1800 17.00 15.84 2.81 22.12 20.33 2.91 27.64 2520 3.02 _3422 30.40 3.17 _ 40.06 38A5 _ 328 48.75 46.75 3.42 _ 54.77 54.77 3.57 82.78 8278 3.72 1400 15,48 14.25 2.85 20.60 _ 18.93 2.97 26.05_ 23.75 3.11 32.88 29.19 323 38.68 3520 3.45 45.00 45.00 3.82 52.51 52.51 3ffi 81.02 61.02 4.00 70 1800 15.80 1454 2.87 20.97 1927 2.99 26.47 24.14 3.12 3335 29.82 328 39.10 35.5E 3.42 45,58 45.56 3,58 53.28 59.28 3.75 81.59 61.59 3.92 1800 16.05 14.76 2.91 2128 1955 3.02 28.84 24.47 3.13 33.71 29.94 3.29 39.47 38.92 3A2 _ 48.04 48.04 3.56 53.98 5358 3.72 61.98 81.98 3.87 1400 13.11 12.07 3.19 1831 18.83 334 23.83 21.72 3.50 29.75 26.42 3.67 37.16 , 33.82 393 43.00 43.00 4.12 4939 _ 49.89 432 58.18 58.18 4.52 as 1800 13.97 12.30 322 113.83 17.12 3.35 2421 22.07 3.50 3022 26.54 3.66 37.65 34.17 399 43.52 4352 4.07 50.88 50.66 425 58.88 58.88 4.43 1800 13.58 12.49 325 18.88 17.35 338 24.50 22,34 3.51 30.57 27.15 3.68 37.88 34A8 3.87 4396 43.96 4.04 51.35 5136 4.20 5933 59.33 437 21-DNA060 Outdoor Section With I X4DN(6 FIUI,IL Inch.or Section 1750 21,14 19.46 333 26.85 24.67 3.46 33.16 30.23 3.60 40.86 36.11 3.79 47.51 43.23 3.95 5522 5522 4.13 8429 84.29 432 7337 7331 4.50 85 2000 21.51 19.79 3.38 2726 25.05 3.48 33.65 30.68 3.61 41.06 36.45 3,77 48.03 43.70 392 55.86 6588 4.08 8495 64.95 4.23 73.54 7334 4.40 �, 2250 21.84 20.10 3A0 2722 2539 3.51 34.07 31.07 _ 3133 41.40 313.77 3.78 48.48 44.12 391 _ 56.46 58.46 4.07 8531 85.31 4.19 73.39 73.39 4.34 Co 1750 2038 18.76 3.48 28.13 24.01 3.02 32.40 29.54 3.76 _40.19 35.69 3.97 46.94 42.71 _ 4,14 _54.50 64.50 432 63.µ 63.µ 4.51 72.41 72.41 4.70 70 2000 20.74 19.06 3.51 28.54 2439 3.84 3287 29.97 _ 3.77 40.59 38.05 3.96 47A4 43.17 4.11 55.15 55.15 _ 4.27 64.14 84.14 4A2 72,69 72.69 4.80 2250 21.08 19.40 3.55 2691 _ 24,73 3.87 3330 _3036 3.79 40.95 _ 3837 3.98 _ 4798 4357 4.09 55,71 55.71 425 8455 64.55 4.38 72.83 72.63 4.53 1750 1958 18.01 3.63 2536 23.30 3.78 31.62 28.83 3.54 39.67 3523 4.16 46.37 4220 4,33 6390 5380 4.52 6259 52.69 4.72 71.50 71.50 4.92 75 2000 19.94 1835 3.87 25.78 23.69 3.80 32.10 2927 3.94 40.12 35.64 4.14 46.85 42.63 _ 429 54.42 54.42 4.48 8333 63,33 4.63 71.81 71.81 4.80 2250 2028 18.85 3.71 26.15 24.03 393 32.52 29.85 3.96 40.49 35.96 4.14 4726 4392 4.28 5497 54.97 4.43 63.78 63,78 457 71.82 71.82 4.73 NOTE:When the required data falls between the published data,interpolation may be performed.Extrapolation is not an acceptable practice. *The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted.The Btuh heating from supplement heaters should be added to those values to obtain total Sys.capacity. t The kW values include the compressor,outdoor fan motor,and Indoor blower motor.The kW from supplement heaters should be added to these values to obtain total Sys.kilowatts. EDB-Entering Dry Bulb • GUIDE SPECIFICATIONS AIR-COOLED,SPLIT-SYSTEM HEAT PUMP GENERAL 214nxA 1-1/2 TO S NOMINAL TONS System Description Fans Outdoor-mounted, air-cooled, split-system heat pump unit — Condenser fan will be direct-drive propeller type, suitable for ground or rooftop installation. Unit consists of a discharging air upward. hermetic compressor,an air-cooled coil,propeller-type condenser — Condenser fan motors will be totally enclosed, 1-phase fan, and a control box. Unit will discharge supply air upward as type with class B insulation and permanently lubricated shown on contract drawings. Unit will be used in a refrigeration bearings. circuit to match up to a packaged fan coil or coil unit. — Shafts will be corrosion resistant. Quality Assurance — Fan blades will be statically and dynamically balanced. — Unit will be rated in accordance with the latest edition of — Condenser fan openings will be equipped with steel wire AHRI Standard 240. safety guards. — Unit will be certified for capacity and efficiency, and Compressor listed in the latest AHRI directory. — Unit construction will comply with latest edition of — Compressor will be hermetically sealed. ANSI/ASHRAE and with NEC. — Compressor will be mounted on rubber vibration — Unit will be constructed in accordance with UL isolators. standards and will carry the UL label of approval. Unit Condenser Coil will have C-UL approval. — Condenser coil will be air cooled. — Unit cabinet will be capable of withstanding Federal Test — Coil will be constructed of aluminum fins mechanically Method Standard No. 141 (Method 6061) 500-hr salt bonded to copper tubes which are then cleaned, spray test. dehydrated,and sealed. — Air-cooled condenser coils are pressure tested and the Refrigeration Components outdoor unit is leak tested. — Refrigeration circuit components will include liquid-line — Unit constructed in ISO9001 approved facility. shutoff valve with sweat connections,vapor-line shutoff Delivery, Storage,and Handling valve with sweat connections, system charge of Puron® — Unit will be shipped as single package only and is stored (R-410A)refrigerant,POE compressor oil,accumulator, and handled per unit manufacturer's recommendations. and reversing valve. Warranty (for inclusion by specifying engineer) Operating Characteristics — U.S.and Canada only. — The capacity of the unit will meet or exceed Btuh PRODUCTS at a suction temperature of °F/°C. The power consumption at full load will not exceed kW. Equipment — Combination of the unit and the evaporator or fan coil — Factory assembled, single piece, air-cooled heat pump unit will have a total net cooling capacity of Btuh unit. Contained within the unit enclosure is all factory or greater at conditions of CFM entering air wiring, piping, controls, compressor, refrigerant charge temperature at the evaporator at °F wet bulb and Puron®(R-410A),and special features required prior to _°F/°C dry bulb,and air entering the unit at field start-up. °F/°C. Unit Cabinet — The system will have a SEER of Btuh/watt or greater at DOE conditions. — Unit cabinet will be constructed of galvanized steel, Electrical Requirements bonderized,and coated with a powder coat paint. Available with dense grille only. — Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of_v to v. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 19 SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01-in.wc. 2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F(12.8°C). 3. Maximum outdoor operating air temperature for cooling mode is 125°F(51.7°C). 4. Minimum outdoor operating air temperature for heating mode is—30°F(-34.4°C). 5. Maximum outdoor operating air temperature for heating mode is 66°F(18.9°C). 6. For reliable operation,unit should be level in all horizontal planes. 7. For interconnecting refrigerant tube lengths greater than 80 ft(23.4 m)and/or elevation differences between indoor and outdoor units greater than 20 ft(6.1 m),consult Residential Piping and Longline Guideline and Service Manual available from equipment distribut- or. 8. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm)vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in.(914.4 mm)may be buried without further consideration.Do not bury refrigerant lines longer than 36 in.(914.4 mm). 9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 10. Do not apply capillary tube indoor coils to these units. 11. Factory-supplied filter drier must be installed. ©Bryant Heating&Cooling Systems 7310 W.Morris St. Indianapolis,IN 48231 Edition Date 03/15 Catalog No.PDS214DNA-03 Manufacturer reserves the right to discontinue,or change et any time,specifications or designs without notice and without incurring obligations. Replaces: PDS214DNA-02 20