Loading...
Plans OFFICE COPY GENERAL NOTES AERIAL VIEW . CODES AND STANDARDS ` 1. ALL WORK SHALL COMPLY WITH 2O17 OREGON ELECTRIC CODE(OEC),2017 OREGON BLUE RESIDENTIAL SPECIALTY CODE,AND ALL STATE AND LOCAL BUILDING AND ELECTRICAL at II BLUE RAVEN CODES. 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. A. A. i. SITE NOTES/OSHA REGULATION „� QJ � 1403 N RESEARCH WAY,BUILDING J 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. ut._ :� ,,,' OREM,UT 84097 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY " ' Cr INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. , r . , a 600-377-4480 1. WWW.BLUERAVENSOLAR.COM 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR z `" a a ' BUILDING ROOF VENTS. ;hT"�' CONFIDENTIAL-THE INFORMATION 4. ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH E.l�� tl, HEREIN CONTAINED SHALL NOT BE THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF •.,? �- 4' USED FOR THE BENEFIT OF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. ' ANYONE EXCEPT . -, '� ,'-� a ` . BLUERAVENSOLAR NOR SHALL IT 5.NO.OF SHINGLE LAYERS-1 ;- - -- '-'s ' <`,,,_., - Y..., „5 BE DISCLOSED IN WHOLE OR IN ,� i .. f PART TO OTHERS OUTSIDE (I) RECIPIENTS ORGANIZATION, SOLAR CONTRACTOR EXCEPT IN CONNECTION WITH THE ' �.. e SALE AND USE OF THE RESPECTIVE 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 7` ;*` i ,+, ,§1 EQUIPMENT,WITHOUT THE 2- IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING '� y WRITTEN PERMISSION OF LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. ' * a 1 1, ' ' BLUERAVENSOLAR LTC. 3- AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED 4 11i 41 IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION .I 1 ,, 1 `. AND APPROVED BY THE AHJ. ; € `' 3 �BCEP 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE t � i "1 NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 1 5095 Southwest CERTIFIED 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND e� a y�c. PV INSTALLATION SEALED WITH A SUITABLE SEALING COMPOUND 1 J�t h Avenue - - 4 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. ,' r ' PROFESSIONAL 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ :,.` - Scott Gurney SUITABLE WIRING CLIPS. ! - A PV-01 1 71 9-01 5866 B. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR CONTRACTOR: VOC UNLESS NOT AVAILABLE. BRS FIELD OPS 9. ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, `` 3$5.498.6700 AC PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT .. =, COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM - ...e " - ' WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(B). -.. 1- "" 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. - ° L- 11. TERMINALS AND LUGS WILL BE TIGHTENED TO MANUFACTURER TORQUE SPECIFICATIONS(WHEN T M ECE�VED PROVIDED)IN ACCORDANCE WITH NEC CODE 110.14(D)ON ALL ELECTRICAL CONNECTIONS. q V EQUIPMENT LOCATIONS MAR I020 1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL �`, ,� ARD co EQUIPMENT WILL BE PROVIDED AS PER SECTION[NEC 110.26]. CITY OF T �.,� 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING '- �- C l(Il-DING Dd�/ISION r TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)-(B)]AND[NEC TABLE 310.15(B)]. Z L CNI 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX T I. w TO THE UTILITY AC DISCONNECT,OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. I— Q) N 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO WIND SPEED: 120 MPH OCCUPANCY - R3 PV1 - COVER SHEET < 3 0 NEC APPLICABLE CODES. GROUND SNOW LOAD: 40 PSF CONSTRUCTION - V-B PV2 - PROPERTY PLAN 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN WIND EXPOSURE FACTOR: C ZONING: RESIDENTIAL PV3 - SITE PLAN p c� '3 c w APPROPRIATE. 7 1— OFFICE COPY SEISMIC DESIGN CATEGORY: D PV4 - EQUIPMENT & ATTACHMENT DETAIL • (n 0 1- PV5 - ELECTRICAL SINGLE LINE DIAGRAM z 5 U) co • ' SCOPE OF WORK PV6 - ELECTRICAL CALCULATIONS & I- c 0 a1 U ELECTRICAL NOTES � N — I- o CITY O TIGARD INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM PV7 MAIN BREAKER DEBATE CALCS. DRAWING BY REVIEWED FOR; ODE COMPLIANCE (IF NEEDED) DIN ENGINEERING Approved: [ A. 4.13 kW DC PHOTOVOLTAIC SOLAR ARRAY• PV8 LABELS & LOCATIONS PV9 CUSTOM DIRECTORY PLACARD DATE OTC: [ j . ROOF TYPE: Comp Shingle :�Li!>ITY OF PERMIT (IF NEEDED - NEC 690.5PLA March i i, 2020 �� ��� MODULES: (14) SolarWorld 295 THE ISSUANCE OF A PERMIT Permit#: INVERTER(S): Enphase IQ7 Microinverters,---- :::Erc):DNE CONSTRUCTION PROJECT NUMBER Address: D .9-� RACKING: Unirac SFM Infinity CUENTS AND OTHER LIABIL. y 73200308 Suite #: A ALL NOT PREVENT The City of Tigard and its 13): ill{* Date: 3 Approved pia+' OFFICIAL FROM SHEET NAME shall be on job S�ae7- REQUIRING THE CORRECTION employees shall not be COVER SHEET OF ERRORS. ORSC 105.4 responsible for discrepancies which may appear herein. PAGE NUMBER REVISION PV1 0 LEGEND INV INVERTER&DC DISCONNECT OLUE RAVEN SUB (E) SUBPANFL LC (N) LOAD CENTER 1403 N RESEARCH WAY,BUILDING J OREM,UT 84097 AC AC DISCONNECT 800-377-4480 M UTILITY METER WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION M AC C N MSP MAIN SERVICE PANEL HEREIN CONTAINED SHALL NOT BE III USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT MSP BLUERAVENSOLAR NOR SHALL IT BEU DISCLOS:OD: D IN WHOLE OR INI O TS TRANSFER SWITCH PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, ❑ p EXCEPT IN CONNEC TION WITH THE ❑ C COMBINER BOX/AGGREGATOR SALE AND USE OF THE RESPECTIVE 0 0 EQUIPMENT,WITHOUT THE PV PV REVENUE METER WRITTEN PERMISSION OF BLUERAVENSOLARLLC. O j FIRE SETBACK 0 ❑ / EMT CONDUIT RUN �p p ❑ (TO BE DETERMINED IN FIELD) f ' ABC EP c CERTIFIED 0 w Q PVWIRESTRING PV INSTALLATION 0 0 0 0 i PROFESSIONAL 0 I t Gurney I PROPERTY LINE LO I #PV-011719-015866 O LL 1- 0 SCALE: 3/32"= 1'-0'' CONTRACTOR: p Z D a s BRS FIELD OPS o O 385.498.6700 L.L.CC In as) 0 JB io ,— a) 0 61c Sic D 0 C gc c ffc ///6"//////g7/////I Q Y c, MFG lg. ffc 6ic t Z i in N igc Igcc Ic &c 0 Q N CA N cc c _c O) 0 - N LL 7 I) 0 1- z 5 Lo >- w 0) C) N co — Lo ROOF ATTACHMENTS SHALL BE SPACED r� N T F— 0 NO GREATER THAN 24" ON CENTER IN DRAWING BY ANY DIRECTION WHERE LOCATED DIN ENGINEERING WITHIN 3' OF A ROOF EDGE, HIP, EAVE, OR RIDGE OSSC 3111.5.3 ITEM 3.2 DATE March 11, 2020 PROJECT NJMRFR DC SYSTEM SIZE: 4.13 kW DC 73200308 ROOF TYPE: Comp Shingle SHFFT NAME (14) Solarworld 295 PROPERTY PLAN Enphase IQ7 Microinverters,----INVERTER PAGE NUMBER REVISION PV2 0 LEGEND \lie INV INVERTER B DC DISCONNECT BLUEAVE`�R UNDERGROUND SERVICE LINE SUB (E) SUBPANEL RAVEN / LC (N) LOAD CENTER 1403 N RESEARCH WAY,BUILDING J OREM,UT 84097 AC I AC DISCONNECT � 800-377-4480 M AC C IN MSP MAIN SERVICE PANEL I I UTILITY METER WWW.BLUERAVENSOLAR.COM E CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE MSP USED FOR THE BENEFIT OF ILL__" J I JB I JUNCTION BOX ANYONE EXCEPT O BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED NWHHO E OR IN TS TRANSFER SWITCH PART TO OTHERS OUTSIDE III IIIRECIPIENTS ORGANIZATION, ❑ EXCEPT IN CONNEC TION WITH THE ❑ ❑ C COMBINER BOYJAGGREGATOR SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE PV PV REVENUE METER WRITTEN PERMISSION OF BLUERAVENSOLAR LLC. jFIRE SETBACK ❑ (TOEMTBE DETERMIT RUN NED NED IN FIELD) BCEP CERTIFIED ❑ I PV WIRE STRING PV INSTALLATION PROFESSIONAL ❑ 1 PROPERTY LINE Scott Gurney ❑ #PV-011719-015866 ❑ ❑ ❑ SCALE: 1/8"=1'-0" CONTRACTOR: ELD ❑ 0 0 EaliffaISI BRS 3 5.498 6 00S O Z 0 0 C ❑ ■ Q CO T JB z 4 N O inCV ffc Sic r1' Q rn N ffc ffc ffc ///r///////ti/////// cc c _c 0 w m W O 1— ffc c Sic IlC z 5 (n _ (J) W cm rn c1s U) c c c c c I-u-) N O� H 0 DRAWING BY MP1 DIN ENGINEERING # OF MODULES: 14 AZIMUTH:180° DATE PITCH:27° March 11, 2020 TSRF:100% AREA: 460.86 SQ. FT PROJECT NUMBER 73200308 DC SYSTEM SIZE: 4.13 kW DC ROOF TYPE: Comp Shingle SHEET NAME SITE PLAN (14) SolarWorld 295 Enphase IQ7 Microinverters,----INVERTER PAGE NUMBER REVISION PV3 0 ROOF ATTACHMENTS SHALL BE SPACED PV MODULE(BEHIND TRIM RAIL) Unirac SFM Infinity TRIM RAIL PV ARRAY INFORMATION NO GREATER THAN 24" ON CENTER INNOP' ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, EAVE, ` LANDSCAPE BLUE RAVEN PV MODULE COUNT: 14 MODULES OR RIDGE OSSC 3111.5.3 ITEM 3.2 # OF ATTACHMENT POINTS: 31 1 11 48" MAX. r MAX. ARRAY AREA: Module Count x 17.51 ft2=245.1 ft2 1403 N RESEARCH WAY,BUILDING J ROOF AREA: 2477.5ft2 PORTRAIT OREM,UT 84097 800-3 OF ARRAY/ROOF: 9.9% (9 ( UERA ENSO 1'-11' -4480 WWW.BLUERAVENSOLAR.COM ARRAY WEIGHT: Module Count x 501bs = 700.DIbs MAX. 48" MAX. ARRAY DETAIL, FRONT VIEW coNFIDENTwL-THE INFORMATION DISTRIBUTED LOAD: Array Weight_Array Area =2.86 Ibs/ft2 SFM Infinity Flashkif Scale: 3/8" = 1'-0" HERUSEIN FOR CONTAINED SHALL of BE POINT LOAD: Array Weight_Attachments =22.6lbs/attachment ANYONE EXCEPT RACKING ATTACHMENTS TO BE Unirac SEM Infinity FRAME BLUERAVENSOLAR NOR SHALL IT STAGGERED BY SHIFTING EACH BE DISCLOSED IN WHOLE OR IN SUBSEQUENT ROW OF ATTACHMENTS PORTRAIT PART TO OTHERS OUTSIDE ONE RAFTER OVER. ® RECIPIENTS ORGANIZATION, r-„ EXCEPT IN CONNED TION WITH THE ® ' SALE AND USE OF RESPECTIVE EQUIPMENT,WITHOUTTHE WRITTEN PERMISSION OF ( „oilBLUERAVENSOLAR LLD. Unirac SFM Infinity UNIRAC TRIMRAIL �� MODULE LANDSCAPE WIDTH ' NABCEP SolarWorld 295 i CERTIFIED 0 PV MODULE O a ' ARRAY DETAIL, SIDE VIEW PV INSTALLATION 27 Scale: 3/8" = 1'-0" PROFESSIONAL urney l (E) ROOF r) A PV-011719-015866 II: •! MEMBRANE 1 ' MODULE O no CONTRACTOR: , (4:, , — 2.5 , UNIRAC SLIDERS AND WIDTH BRS FIELD PS I— I J TRIMRAIL ROOF ATTACHMENTS 385.498.6700 I— coai To I FLASHING J (n 2.5" MIN. EMBEDS la— 5/16" STAINLESS STEEL LAG BOLT ROOF TYPE: Comp Shingle 0 O WITH 2-1/2" MIN. EMBEDMENT ROOF FRAMING TYPE: Manufactured Truss a) AND FLAT WASHER N (} (E) BUILDING RAFTER OR TOP CHORD(TRUSS)2x4 ( 24"O.C. STRUCTURE CEILING JOIST OR BOTTOM CHORD(TRUSS) 2x4 @ 24"0.C. Q cr) T Z 4 N 4 O Lr) T N c"�n N. N Unirac SFM Infinity 0) 3 o O (q W O SolarWorld 295 O 5 (n O u) 0 • PV MODULE s LC) -p } ZQ I---al 0) o 05 Cn — CA CA N H 0 o_ - O O L,y I (E) ROOF DRAWING B" w 2.5" MEMBRANE DIN ENGINEERING J _n _" c —_ BAIL UNIRAC SLIDERS March 11, 2020 U --610111111111111111 J 2.5" MIN. EMBED. PROJECT NUMBER I- FLASHING 73200308 w 5/16"STAINLESS STEEL LAG BOLT SHEET NAME = WITH 2-1/2" MIN. EMBEDMENT EQUIP. DETAIL AND FLAT WASHER 41111111 (E) BUILDING PAGE NUMBER REVISION STRUCTURE PV4 0 I i) 10 AVM THH14/711WN-2,CU.,RAO(( 14 0 A AC (1) 10-2 UF•11W/G.T1604/THWN-L SCUD CU. MAAX 14.0 A AC II) 10.2 UF-0(or NAB WM,THFIN/THWN-2.Sl MAX 14.0 A AC (1) 12.2 TC-ERTHHN/T14WN-2,CU. MAX 14,0 A AC ..1C II) 10 AWG THNN/THWN-2,CU.,RED(L2) 240 VAC 3 240 VAC 2 240 VAC 1 (1) 6 A WG RARE,QI IEGC) 240 V AC ,J--** (i) 10 AWG Tt4QVTHWN-2.al.WHITE(NI (1) 10 AWG THI3N/THWN-$CU.,GREEN(EGC) (1) 3/4 INCH EMT EXTERIOR (1) 3/4 INCH EMT EXTERIOR INTERIOR EXTERIOR BLUE RAVE N ALL CONDUIT TO BE RAN AT LEAST 7/8"ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. 1403 N RESEARCH WAY,BUILDING J OREM,UT 84097 800-377-4480 W W W.BLUERAVE NSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE SUPPLY SIDE CONNECTION EQUIPMENT,WITHOUT THE 206,NEC 230.79(D), WRITTEN PERMISSION OF (E)200A MAIN SERVICE PANEL NECPER 705.12(A)NEC3 .4 (14)SolarWorld 295 BLUERAVENSOLAR LLC. (E)200A/2P MAIN BREAKER Enphase IQ Combiner 3 UL 1703 COMPLIANT PV AC DISCONNECT X-IQ-AM1-240-3 'JUNCTION BOX(S) E FUSED,10okAIC-R (SOLAR LOADS ONLY) FONR YWIRE SPLICLING (14)Enphase 107 Microinverters MICRO (E)200A/2P LOCKABLE,VISIBLE OPEN O-C BLEO(O-OEflAOR UL1INVER MPLIANT NABCEP F SERVICE RATED • 60A,240V,2-POLE UF-B USED FOR 7 MODULES MAX FOR ALL SUB-BRANCH CERTIFIED ENTIRE HOMERUN CIRCUIT(S)TO COMPLY WITH VRIS, CALCS PV INSTALLATION (E) _N JUNCTION BOX JUNCTION BOX PROFESSIONAL LOADS FUSES _ ney Scott011 19 01 CLASSR - (N)20A/e:_7 \_=�J (1) CIRCUIT Ill �p�� qPV-011719-015866 CONTR�, , �� '" OF 14 MODULES �� �� G �I _F �� -T l hi I CTOR: BRS FELD OSEGC �- - - - — — — — — - 120/240 VAC 7 - V v 385.498.6700 60HZ 1 PHASE TO UTILITY 16 ';'J O v 0 GRID c a)CI :21"- Q_ (E) GROUNDING MLELECTRODE(S) Z � 4 T _£ �= t/J CN T RI "" WO ? o - u_Z .5 Cnn„. - t W rn rn CA 4 1"`„ H a6i a) U 7.. (A N H ❑ ' `, ` DRAWING BY DIN ENGINEERING - . ; 4., l' ' INTERCONNECTION NOTES ,, i 1. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)]WITH SERVICE DArE ENTRANCE CONDUCTORS IN ACCORDANCE WITH[NEC 240.21(B)] x March 11, 2020 DISCONNECT NOTES ) ' "� 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS �' " ) s'. r „ � PROJECTNUMBER OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE 73200308 TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) y yl 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE r� :, M=, SHEET NAME LOCKABLE,AND BEAVISIBLE-BREAKSWITCH �F [D : I 1 ELEC. 3 LINE DIAG.f . r � ^ PAGE NUMBER REVISION PV5 0 MODULE SPECIFICATIONS Sunmodule Plus SW295MBlack DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER(STC) 295 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG.HIGH TEMP MICROINVERTERTO MAX.SHORT CIRCUIT CURRRENT IISC)= 14.0 A AC ' MODULE VOC 40 V DC STATE Oregon JUNCTION BOX(1) MAX.CURRENT(ISCX1.25)= 17.5 AAC MODULE VMP 31.5 V DC CITY Tigard CONDUCTOR(TC-ER,COPPER 190'C))= 12 AWG BLUE RAVEN MODULE IMP 9.45 A DC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 30 A MODULE ISC 10.1 A DC ASHRAE EXTREME LOW TEMP('C) -6 AMB.TEMP.AMP.CORRECTION= Q96 VOC CORRECTION -0.31%J'C ASHRAE 2%AVG.HIGH TEMP('C) 32 ADJUSTED AMP.= 2&8 > 17.5 1403 N RESEARCH WAY,BUILDING J VMP CORRECTION -0.43%PC JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 14.0 AAC OREM,UT 84097 SERIES FUSE RATING 25 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 OR 2 CIR 3 CIR 4 OR 5 CI 6 JUNCTION BOX(2) MAX.CURRENT(ISC X1.25)= 17.5 A AC 800-377-4480 W W W.BLUERAVENSOLAR.COM ADJ.MODULE VOC @ ASI*AE LOW TEMP 43.8 V DC NUMBER OF MODULES PER MPPT 14 { CONDUCTOR(UF-B,COPPER(6.0'C))= 10 AWG ADJ.MODULE VMP @ ASHRAE 2%AVG.HIGH TEP 26.2 V DC DC POWER RATING PER CIRCUIT(STC) 4130 CONDUCTOR RATING= 30 A CONFIDENTIAL-THE INFORMATION - - HEREIN CONTAINED SHALL NOT BE TOTAL MODULE NUMBER 14 MODULES CONDUIT FILL ORATE.1::, 1 USED FOR THE BENEFIT OF ANYONE EXCEPT MICRO INVERTER SPECIFICATIONS Enphase IQ7 Mlcro¢mrerters STC RATING OF ARRAY 4130W DC AMB,TEMP.AMP.CORRECTION= 0.96 BLUERAVENSOLAR NOR SHALL IT POWER POINT TRACKING(MPPT)MIN/MAX ,22 - 48 V DC AC CURRENT la MAX POWER POINT(IMP' 14.0 ADJUSTED AMP.= 28.8 > 17.5 BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MAXIMUM INPUT VOLTAGE 48 V DC MAX.CURRENT I IMP X L25) 17.5 JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 14.0 A AC RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 COMBINER BOX(3) MAX.CURRENT(ISCXL25)= 17.55 AAC SALE AND USE OF THE RESPECTIVE MAXIMUM USABLE DC INPUT POWER 350 W MAX.COMB.ARRAY AC CURRENT(IMP) 14.0 CONDUCTOR(lW-R COPPER(60°C))= 10AWG EQUIPMENT,WITHOUT THEWRITTEN PERMISSION OF MAXIMUM OUTPUT CURRENT 1 AAC MAX.ARRAY AC POWER 3360W AC CONDUCTOR RATING II 30 A BLUERAVENSOLAR LLC. AC OVERCIJRRENT PROTECTION 20 A CONDUIT FILL DERATE= 1 MAXIMUM OUTPUT POWER 240W AC VOLTAGE RISE CALCULATIONS DIST(FT) COND. JRISE(V) VEND(Vi%VRISE 107-7 AMB.TEMP.AMP.CORRECTION= 0.96 NABCEP CEC WEJGHTEDEFFICIENCY 97% VRISE SEC.1(MICROTOBOX) 25.2 12 Cu. 0.71 240.71 0.30% ADJUSTED AMP.= 28.8 > 17.5 CERTIFIED VRISE SEC.2(JBOXTD COMBINER BOX) 70 10Cu. 2.49 24249 L04% COMBINER BOX TO INVERTER RATED AMPS= 14.0AAC PV INSTALLATION ACPHOTOVOLATTC MODULE MARKING(NEC 690.52) VRIS€SEC.3(COMBINER BOX TOPOI) 10 10CU. 0.36 240.36 0.15% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS X1.25)= 17.5AAC PROFESSIONAL NOMINAL OPERATING AC VOLTAGE 240 V AC TOTAL VRISE 3.56 243.56 L48% CONDUCTOR(THWN-2,COPPER(75'CTERM))= 10 AWG Scott Gurney NONALOP€RATING AC FREQUENCY 47-fill IQ CONDUCTOR RATING= 35 A #PV-011719-015866 MI MAXIMUM POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) CONDUIT FILL DERATE= 1 CONTRACTOR: MAXIMUM AC CURRENT LO A AC AC OUTPUT CURRENT 14.0 A AC ANS TEMP.AMP.CORRECTION= 0.96 BRS FIELD OPS MAXIMUM OCPD RATING FOR AC MODULE 20 A AC NOMINAL AC VOLTAGE 240 V AC ADJUSTED AMP.= 33.6 > 17.5 385.498.6700 cu 0 GROUNDING NOTES STRANDED,AND BARE WHEN EXPOSED. 690.8] FOR MULTIPLE CONDUCTORS m ❑ 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690-47]AND 11.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED N [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED.PER NEC, 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG AT LEAST 7/8"ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO[NEC TABLE > GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND SHALL BE USED WHEN EXPOSED TO DAMAGE). 310.15(B)(2)(a),NEC TABLE 310.15(B)(3)(a),&NEC 310.15(13)(3)(c)]. Q C`') BONDED TO AT THE SERVICE ENTRANCE.IF EXISTING SYSTEM IS INACCESSIBLE, 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV . . _C T OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE 0 Z d- N GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF USED TO PROTECT WIRE FROM SHARP EDGES • ui CNJ CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 � u) CA N 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL 14.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47],(NEC TABLE 250.66],DC INSULATED,90°C RATED,WET AND UV RESISTANT, RATED FOR 600V 0 C (7) DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER)IF SYSTEM GEC SIZED ACCORDING TO[NEC 250.166],MINIMUM#8AWG WHEN 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER Cr C .0 cm 2 SMALLER THAN#6 AWG COPPER WIRE PER NEC 250-64B.THE GROUNDING ELECTRODE INSULATED,#6AWG WHEN EXPOSED TO DAMAGE. VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. 0 CI 5 N LU CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS 15.EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION Li_ ? 0 0 H WITHIN LISTED EQUIPMENT PER[NEC 250.64C.]. EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN 13. VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS z 5 u } 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS W O C") c13 U) NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING FOLLOWS: DC POSITIVE-RED(OR MARKED RED),DC NEGATIVE-GREY(OR MARKED GREY) �- 1- 00 CD o ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. WIRING&CONDUIT NOTES 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: Cl) N - I- ❑ 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 1.ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK) DRAWING BY 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC APPROVED FOR THE SITE APPLICATIONS 16. AC CONDUCTORS>4AWG COLOR CODED OR MARKED: DIN ENGINEERING 690.46]. 2.BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED PHASE A OR L1-BLACK,PHASE B OR L2-RED,PHASE C OR L3-BLUE,NEUTRAL- DIN ENGINEERING 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC CONDUCTOR(USE POLARIS BLOCK OR NEUTRAL BAR) WHITE/GRAY 690.42]. 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT. REDUCING WASHERS 'USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY DATE 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT DISALLOWED ABOVE LIVE PARTS,MEYERS HUBS RECOMMENDED BE USED INSIDE March 11, 2020 THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR 4. UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT "USE-2 IS AVAILABLE AS UV WHITE TO ANOTHER MODULE. OFF THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A-B).300.4 17. RIGID CONDUIT, IF INSTALLED, (AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROJECT NUMBER 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR PROTECT WIRES. 73200308 IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH RUNS. BE EITHER EMT, FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31,NEC SHEET NAME AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR 250.118(10).DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 ELEC. CALCS. GROUNDING LUGS. CABLE LISTED AND IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT; ROUTED TO 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND SOURCE CIRCUIT COMBINER BOXES AS REQUIRED COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC PAGE NUMBER REVISION GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 7.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 330.30(B). PVF) 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR LABEL 1 - LABEL 7 FOR PV DISCONNECTING MEANS WHERE ALL AT DIRECT-CURRENT EXPOSED RACEWAYS,CABLE TRAYS,COVERS AND ENCLOSURES OF JUNCTION BOXES,AND OTHER »'". ` TERMINALS OF THE DISCONNECTING MEANS MAY BE F . WIRING METHODS;SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES,WALLS,PARTITIONS, ELECTRIC SHOCK HAZARD ENERGIZED IN THE OPEN POSITION. CEILINGS,OR FLOORS. BLUE RAVEN TERMINALS ON THE LINE AND [NEC 690.13(B),NEC 705.22] [NEC 690.31(G)(3&4)] LOAD SIDES MAY BE ENERGIZED SOLAR— THEOPENTl PV SYSTEM EQUIPPED, LABL 8 OREPV SYSTEMS THAT SHUT DOWN THE ARRAY LABEL 11 c��.t�tYf��a AND CONDUCTORS LEAVING THE ARRAY: PERMANENT DIRECTORY TO BE LOCATED AT 1403 N RESEARCH WAY,BUILDING J MATH RAPID SHL OO ��many MAIN SERVICE EQUIPMENT LOCATION IF ALL OREM,UT 84097 LABEL 2 pMO atom SIGN TO BE LOCATED ON OR NO MORE THAN 3 ELECTRICAL POWER SOURCE DISCONNECTING FT AWAY FROM SERVICE DISCONNECTING - N tp1NBrKA40AKiiAILAIM Yntri 800-377-4480 t I e; AT EACH DC DISCONNECTING MEANS,INCLUDING THE SiceMMOTTE _ Pc3 A c01,41 W IN 40UYtAASUMAC MEANS (SOLAR ARRAY RAPID SHUTDOWN MEANS TO WHICH THE PV SYSTEMS ARE 'Of4'RI3CNR) APAPICYAINOVM 041rWFtEGTNii SWITCH)ARE GROUPED AND IN LINE OF SITE OF WWW BLUERAVENSOLAR. M DC DISCONNECT AT THE INVERTER. ONNECTED AND SHALL INDICATE THE ORW4°APO LABELED TTiE OF 01F L• !., ,]„ z - ; B Al,T- MAIN SERVICE DISCONNECTING MEANS. [NEC 690.53,NEC 690.13(B)] ldn DUCE M LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN ANpros.T CC TN1S LOGMM�N [NECiONFIDENTIAL-THE INFORMATION 011:0r1At�� , SWITCHES IF NOT AT THE SAME LOCATION. - - - NEC 690.56(C)&NEC 705.10]. HEREIN CONTAINED SHALL NOT BE MAXIMUM VOLTAGE V'OC : --tr T+flfYYrY -. [NEC 690.58(C)(1)(A)] USED FOR THE BENEFIT OF MAX CIRCUIT CURRENT AMPS LABEL 12 ANYONE EXCEPT '"" -e' BLUERAVENSOLAR NOR SHALL IT LABEL 9 , °/kWARNIN ` PERMANENT DIRECTORY TO BE LOCATED AT BE DISCLOSED IN WHOLE OR IN S°LAIR Pd 1 STEM LOUIPPEt� FOR PV SYSTEMS THAT ONLY SHUT DOWN SOLAR ARRAY RAPID SHUTDOWN SWITCH PART TO OTHERS OUTSIDE 1oA NtA 10 neS worm&iSALA DENOTING THE LOCATION OF THE SERVICE LABEL 3 WITH RAPID SHUTDOWN CONDUCTORS LEAVING THE ARRAY: RECIPIENTS ORGANIZATION, SIGN TO BE LOCATED ON OR NO MORE THAN 3 ELIPPUED FROM HAINOIS CATER EQUIPMENT LOCATION IF SOLAR ARRAY RAPID EXCEPT IN CONNEC TION WITH THE PHOTOVOLTAIC SYSTEM AT POINT OF INTERCONNECTION,MARKED AT AC r FT AWAY FROM SERVICE DISCONNECTING IJTtJTY p19(SOF Ci LOCATED SHUT DOWN DISCONNECT SWITCH IS NOT SALE AND USE OF THE RESPECTIVE DISCONNECTING MEANS. : volumpowcoatitsts ji, MEANS TO WHICH THE PV SYSTEMS ARE GROUPED AND WITHIN LINE OF SITE OF MAIN EQUIPMENT,WITHOUT THE �! AC DISCONNECT � [NEC890.54,NEC690.13(B)] Ofide�`t^p�cMr�& ,,� CONNECTED AND SHALL INDICATE THE SERVICE DISCONNECTING MEANS. WRITTEN PERMISSION OF RATED AL OUTPUT CURRENT A TrtARR1lIELWani 1 LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN [NEC 705.10] BLUERAVENSOLAR LLC. SWITCHES IF NOT AT THE SAME LOCATION. OPERAIMAC LTX% 11 [NEC 690.56(C)(1)(B)] LABEL 13 PERMANENT DIRECTORY TO BE LOCATED AT MAIN NABCE P SERVICE EQUIPMENT DENOTING THE LOCATION LABEL4 .. , LABEL 10 ►ONER10MSWIL rAENDOISUTLIECI OFTHEPVRAPIDSHUTDOWNSYSTEM CERTIFIED IF INTERCONNECTING ON THE LOAD SIDE,INSTALL THIS " SIGN LOCATED AT RAPID SHUT DOWN WOROOF MOWED OMARA Y.SOLAR DISCONNECTING MEANS IF SOLAR ARRAY RAPID d t LABEL ANYWHERE THAT IS POWERED BY BOTH THE - DISCONNECT SWITCH[NEC 690.56(C)(3)]. ArwAY RAPID 810.8 006910111001N1GCTII SHUT DOWN DISCONNECT SWITCH IS NOT PV INSTALLATION UTILITY AND THE SOLAR PV SYSTEM:THE MAIN SERVICE LOOVEPlxnaroErtIXTTOUwMftIENIVEr. GROUPED AND WITHIN LINE OF SITE OF MAIN PROFESSIONAL DUAL POWER SUPPLY PANEL AND SUB PANELS. v, - t) SERVICE DISCONNECTING MEANS.[NEC 705.10, Scott Gurney SOURCES:UTftfY GRID AND [NEC 705.12(B)(3)] NEC 690.56(C)(1)] #PV-011719-015866 PV SOLAR ELECTRIC SYSTEM CONTRACTOR: LABELING DIAGRAM FOR MICRO INV.: BRS FIELD OPS MAIN SERVICE PANEL 385.498.6700 , LABEL 5 EXISTING SUB PANEL PV COMBINER Ai i ;p, ,,, „ PLACED ADJACENT F OM THE IINVERTERTOTHE BACK-FED BREAER IF TIE IN CONSISTS OF LOAD O O (IF WHERE INT RCONNEOCTIONF IFUSED SUBPANETOL COMBINE AC JUNCTION BOX INVERTER OUTPUT CONNECTION N CONNECTION TO BUSBAR.EC 705.12(B)(2)(3)(b)] IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS OR AC COMBINER BOX [SIDEN DO NOT RELOCATE 0 13 IF BROEAKEROUSED O O O O D a THIS OVERCURREN7 — DEVICE °°° ® Q aa) & ,o Q ¢' 011 13 OR IF BREAKER USED CO OR PLACARD 8 OR O T PLACARD Z N A (ONLY IF 3 OR MORE SUPPLY SOURCES TO 5 O O N =� A BUSBAR) O � 11 0 CV W SIGN LOCATED AT LOAD CENTER IF IT (ONLY IF PV (ONLY IF PV 0--- o N. NISEQU TENT FED BY WLTELE CONTAINS 3OR MORE POWER SOURCES INTERCONNECTION NTERCONNECTIOI ¢ 0) — SOURCES TCTAL RATING OFALL [NEC 705.12(B)(2)(3)(C)] CONSISTS OF LOAD CONSISTS OF LOAD cl) U) SIDE BREAKER) SIDE BREAKER) 2 .0 0) CL RRENT DEVICES,FTF l WING — ra , ,, LL1 DEVICE SUPPLY ALLEXCEED LABELING DIAGRAM FOR STRING INV./DC OPTIMIZER INV.: 0VERCURRENT 0 F AMPAfiaTYOf EUSSAR MAIN SERVICE PANEL — L Lc-) "O >- O EXISTING SUB PANEL PV COMBINER INVERTER(S) [1J Cr) Cr) t0 U) (IF WHERE POINT OF SUBPANEL- 1- N tjj 0 O&O INTERCONNECTION IF USED TO COMBINE U) N r 0 IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS IF BREAKER USED O O 0 DRAWING CDINENGINEERING ° ° OORO — °°° O&O - ® O DATE 0 OR 0 IF BREAKER USED Au JUNCTION BOX March 11, 2020 OR PLACARD 0 OR O oc OR COMBINER BOX LABELING NOTES: PLACARD 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO O O PROJECT NUMBER DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND (ONLY IF PV (ONLY IF PV O i O O O 73200308 MAKE APPROPRIATE ADJUSTMENTS. NTERCONNECTION INTERCONNECTION 2. LABELING REQUIREMENTS RASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD CONSISTS OF LOAD CONSISTS OF LOAD n O 7 SHEET NAME 19010.145,ANSI 2535. SIDE BREAKER) SIDE BREAKER)3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. LABELS 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND INTEGRATED DC DISCONNECT SHALL NOT BE MINIMUMHANDWRITTEN[NEC HEIGHT110.H1] `ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS 5. AND LABELS M N A LETTERD[IFC OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE, PAGE NUMBER REVISION AND PERMANENTLY AFFIXED[IFC 605.11.1.1] PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. PV8 0 \IF- BLUE RAVEN .r°inverters 1403 N RESEARCH WAY,BUILDING J Enphase IQ 7 and IQ 7+ Microinverters OREM,UT 84097 800-377-4480 INPUT DATA(DC) 1Q7-60-2•LiS i IQ7-60-IP-US 11)7PLLIS-72.2•DS I 1197PLUS•72-13-US VvVvW BLUERAVENSOLAR.COM Commonly iseedModule pa Minge' 235W-350W+ i3.5 W-440 W• Module compatibility 60,c,eli PV modules Only 60-cell and 72-cell PV module, CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE VAMM The high-powered smart grid-ready N4 urn input DC voltage 48 V 60V USED FOR THE BENEFIT OF Enphase Enphase IQ 7 Micro"and Enphase 10 7. Micro' Peak power hackin g v oltage 27 V-37 V 27 V-45 V ANYONE EXCEPT BLUE RAVEN Operatng range 16'1/ 4.9V 15 V-60 V SOLAR NOR SHALL IT BE IQ 7 and IQ 7-' dramatically simplify the installation process whileMintMx a Wan lt a eaag Max DC Hurt cecul current grixlule hicll :12 y 48 V 22 t 15A l DISCLOSED IN WHOLE OR IN PART i 60 V 15A TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION EXCEPT IN achieving the highest system efficiency. Over sollage deal DC port II II CONNECTION WTH THE SALE AND Microinverte; _ Part of the Enphase IQ System.the IQ 7 and DC porlbackteed current Ini array configuration 0 A BA USE OF THE RESPECTIVE I a 1 ungrounded array,No addrliOnal DC sae protection te-quIrel EQUIPMENT,WITHOUT THE AC side protection reriutree mai 20A pa blanch circuti WRITTEN PERMISSION OF BLUE IQ 7+Microinverters integrate with the Enphase RAVEN SOLAR LLC OUTPUT DATA(At) IQ 7 Maroloverter IQ 7e Micrelneerter IQ Envoy",Enphase IQ Battery-.and the Enphase Peak output power 250 VA 205VA Enlighten monitoring and analysis software_ Maximum co.-gnaws output power 240 VA 290 VA NABCEP Nominal(L•L)soltagerrenge 240Vi 206 V i 240 Vii 206V/ 211-264 V 183-229V 183-M9 V IQ Series Microinverters extend the reliability Maximum c ont etudes output current I D A 1240 VI 1 15 A)208 V) 1 21 A 211-264 V(240 VI 1 39 A(208 VI CERTIFIED standards set forth by previous generations and Nornhal frequency 60 etz 60 HZ PV INSTALLATION [ landed frecarency range 47-68 Hz 47-58 I-0 PROFESSIONAL undergo over a million hours of power-on testing, AC short circuit fault mated owe 3 cyders 5 8 Anna 5 e Anna Scott Gurney enabling Enphase to provide an industry-leading Maximum units per 20 A(i_..l.1 bra ridi circuit' 16(240 VAC) 13(206 VAC, 13(24D VAC) 11 (208 VAC I I PV-011719-015888 warranty of up to 25 years. Opervelltage dee AC port III III CONTRACTOR: AC pal backfeed current 0 A 0 A BRS FIELD OPS Power fectco tootling 1 0 re Power factor(adhiniii . 0 7 leading 0 7 lagging 0 7 haling 0 7 Le 385.498.6700opold EFFICIENCY @210 V @nos V doit40 V (0206 Y Pick CEC rfficiencr 97 6 It 976's. 9-T.5 CEC weighted efficiency Ea t Install MECHANICAL DATA o sy Ambient temperature range .406C to r-65•C •••-• • Ughtwetgirt and sirnple Relative hone:My range 4••:.to 100%.(condensing) ,.; • Faster installation web improved,lighter two-wire cabSing Comecter type(827-60-2-US 6 1Q7PLUS•72-2-US) MC4(or Amphora'I44 UT X with additional 0-0CC.5 adapter) Connector type(837..6043.0S 13.1Q7PLJS.77:8-US) Fr tends PV2{MC4 intern-L.84mb* _ __, _ , _ • Buht-in rabid shutdown compliant INEC 21314 E 2017) Adaptors for modules with MC4 or UT X connectore — .IN2 to MC4.order ECA-S20-522 I II -PV2 to UT X order EGA-820-525 Productive and Reliable ob.....luni twm WO/ 212 trim x 175 rem*30.2 war(without twactal) — - Weight 1 OE irg.',2 38 les) • Opitirnized for fugh pow sr ed 60-cell and 72-call'modules Coettng Neural cermiction-No fans • More than a rrellion hours cri se-sting Approved for wet iocatiena Yes • Class It double-insulated enclosure Polution degree P03 " • UL listed Enclosure Class II double-insulated,COVTO$,on rrotivent Polymeric enclosure -L., Emilie aim de atrocory i uv gs.posure rating NEM A Type 6 ir outdoor FEATURES Smart Grid Ready coninUnicrticri Power Une Coneturacil Se(PLC) Monitoring Enlighten Manager and MyEnlighten mongering options •.-- • Carralres wet,advariced grid support,voltage and Oath opl lona require instellgel ion of an Erphase ID Envoy :,-- IP frerarency ride-through requicerieixs Disconnecting mean rho AC and DC correctors Nee been evekialed end'waved by ill for use as the eel-bras ii • Remotely updates to respond to charging connect rewired by NEC 6 40 grid requirements Compliance CA Rule 21 ill.R.1741-5A) . Ut.62109-1,U11741/IEEE1547.FCC Part 1 5 Clays B. ICES-0003 Class B. • Configurable for varying grid profiles CA/VC SA-C22 2 NO 1127,1-01 • Meets CA Rule 21 (UL 1741-SA) This product NUL L heed es PV Rapid Shut Down Equipment and contemns with NEC-2014 end NEC•201 7 section 69012 and C22 1-2015 RMe 64-21S Rape Shutdown of PV Systems tra AC and DC c4nductora,when inn illad according menufacturer's instructions 71441 10 74 MVO ra rOirl11 et to support 72-call modulascft — — WM/ I.No•”,14.1‘nd I-I.C,A.-rot 44 f;nr.I r ..L.b7 I.can Motu rubilps.licsWima.cerVan.iiaisubuoiltoliAble caropeitar : Na'5 nINi Nil 11 l.01 1-0094 ran Le tl.tvndedLNAVOkloormAl,11..-cuJinl(fly lie vITAT °= r.ae r6av,n,r Rrir,to Ivoral,mil ges.mtellc warren the ourtam ni et crorvemBer.pre branch 44 y11411 aims ENPHASE. SHEET NAME To learn more about Enphase offertigs,visit enphasexom %.,..f To learn more about Enphase offerings,visit eaphase.corn ENPHASE, SPEC SHEET ....... PAGE NUMBER REVISION SS 0 . . ...- BLUE RAVEN Enphase IQ Combiner 3 Eriphase Networiung 1403 N RESEARCH WAY,BUILDING J MODEL NUMBER OREM,UT 84097 lt)Combiner 3 X4ChAM11-2,40-3 10 Combiner 8 wall EaPhase ii3Eneor Waded alretat board tar Intagentrid revenue grade PV 800-377-4480 ;Abdution metering tANSI C12 20 t1-0 5'5)and options&odrtsumpalOnMenit8rM0 tah 2 Tal VWVIN BLUERAVENSOLAR.COM ACCESSORIES and REPLACEMENT PARTS(not arc luded.cede',. ..• ,•'-.• CONFIDENTIAL-THE INFORMATION &Otte.MObbe Connect" HEREIN CONTAINED SHALL NOT BE gal_MODE ht 413.(4C i 12-year debt Oen) Riog and slay iirdatte 44 grade ceeLliar modern Mtn data plan tot systems up to PO USED FOR THE BENEFIT OF b.al I MODEM-21 f,3•C t 5-yew data Man) microinvertete (Available in the US,Carlotta,Mexico,Puerto R .and the US Virgin Iolanda. ANYONE EXCEPT BLUE RAVEN crt000nem4in(4G beiarlitE4A i 5gleg date 0 km) neon trete a adaddele cedular melon In the Irolettation area 9 SOLAR NOR SHALL IT BE Enphase , The Enphase IQ Combiner 3 oz,th Enphase I,cosureplion Mond/tit-yr CT CT-200-SPLIT Spin cote=Tem tranTfwrwers enabie wivie home consumption metering f7,-'2 5'.....',, DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS IQ IQ Envoy' con so dates nterconnect on ORGANIZATION,EXCEPT IN Combiner 3 ci,....,13reekete 810A-2-240 Support*Eaton OR210,8R21 20 5,BR2 ,BR229,9R240,8I1250,and 8R250 choice breakers Cecuit breaker,2 dote 10A,EMOnaR210 CONNECTION WITH THE SALE AND egu orient nto e s ng e elliC osure and BROM-2-240 Ciente breaker,2 prilt.15A,EalleeteR2Is USE OF THE RESPECTIVE EQUIPMENT.MATHOUT THE (X-IQ-AM1-240-3) stream nes PV and storage ,nsta at ors by BEL8-2042P-240 cmia ben an 2 peas 20A,Eaton 818220 WRITTEN PERMISSION OF BLUE EPLC-01 Power Ine!Arne.COMnrriummation bridge pm),quantity 2 RAVEN SOLAR LLC crovtd,ng a cons stern,pre-w,red SOILItiOrl for XA-PLUG-120-3 Accessory receptacle for Paper Lin*Car/tar In Kt Combiner 3 bemired los EPLC-01) MN/ENV-PULA-3 Replacement IQ Envoy printed circuit board(PCS)tor Combiner 3 res-dent a app!,cat-ons It eers up to'our NABC EP ELECTRICAL SPECIFICATIONS 2-poe, nput c mu ts end Eaton BR ser,es CERTIFIED Ratec Continuous duty busbar assernby systml voltage 120/243 VAC,612 Ht PV INSTALLATION Eaton 8R/sienna Mahar 194.01,0 125A PROFESSIONAL Scott Gurney Max comahmus.tune rating(output to.grid) 65 A a PV-011719-015868 Max.fusercirouit rating foutpuN 90A CONTRACTOR: Branch circuits(solar and/or storage). Up to fOut 2.-pale Eaton BR aeries Distributed Generation(09)breakers onty(not included) BRS FIELD OPS Mo.corierwouy tUrretli rating latpUt arare RV) 54 A 385.498.6700 Max total branch ci-cuis b- aker rating(input) BOA rri custrbuted veneration I MA with ICI Envoy Otto tor,nckAa0 Smart Pt odurdeart Meter T 20t3 A goad cora pregnialiee arid wired to ha Envoy .1.e 'N.:, • Includes ICI Envoy1of comreitielcatlea MECHANICAL DATA ,.,../ and contror . . 8/91Moilons(WMMEO 405x 325 x 16 8cm(19 5"x 14,25.x 6.631 elaighl Is 21.06*(53.5 ern with mounting bracketa) I t I / ..„4-try oi Ye mi • Flexible netivorking supports Wi-Fi, WMPO 2 5 kg 116 5 MN e IIIIIII.,„ , ttig i, Ethernet,or ceiltilar IR-i Y i • .-,-. ; AmbRalt tampon/tuna num* 401-C to+OM C(4109 to 1158 F) c:1 81 4 ii. - - ;I 11 ' 1 . Optional AC receptacle available for PLC bootie Cooling Natural unions:0e.plue Nest ebteld -?, -ll . i t i- • : •,t • Ptovides production Metering arta aphonal Enclosure ameonertentel retina Outdoor,Watt,c*tiffitsi NEMA type alt polvearbansis vase:rumen consumption monitoring Was stun - ZIA to Se A breatiar nputs 14 to 4 AWG copper conductors r„1 0 ,,:,t. ., -: 1,, I ' , • 69 A tgoa kw Manch input 4 lo tiOAWG copper conductors - Main lug combined output 10 to 283 AWG comer conductora t, "` - - , 11 ';'. * Neutral and ground la to 1.'0 030W C0ndix150a Simple ,, ,..-!! --- -r. .4.,: , ,,,,,,,,,,s,...,local code requireenents tot conductor sizing (*. .1.." :', , - ,' e 4- l',,. a 0 . • Henon arm from previous combiner AlitIllide To 2000 memo Itt 550 Teti I , i„ IN -0 -, ,-t ta Centered mounting brackets support single INTERNET CONNECTION OPTIONS xt-kit I- . ..,..'- stud moIjn1rng Integrated W141 ;I I' 80/11bigin ' ,„ • Supports Mick and side conduit entry Ethernet Oottonal,802 3,eat5E(04,Cat 6)UTP Ethistnet cable (AM'notated) ., s.....zir .'''' , • Up IC lour 2;pole btanch babbitt;for 2413 VAC Cellular Optfonal,CELLM0DEM-9I OM et enimoormo3140 ta°CaLMODEM-fiet MG based LTE4911 plugdn breakers(not inciuded) ',f104 inC14466) • at)A total PV Of storage branch cum lta COMPLIANCE CoMplaince.Y.ditibmat Lk 1741 Wait-Rat=2 no 1071 Reliable Ai CFR.Part IS,Cteme 4,ICES 003 Production metering.ANSI 912 33 anance elan 0,5(RV ptedubhon) / Durable Nat L-certified NEMA type Compliance IQ Envoy LA,60601.11CA tit,SA 22.2 No.610113-1 3R enelostee 4111) • kiveiyeet warranty *Consumption monitoring is requaed for Encibase Storage System • UL listeds To learn'rive about EnphaSe offerings,visil eapheaccom LISTED -,„-, ,,ENPHASE, ,, e, rala-it,'-'1",.,Ji 1."ri"'"1„?.4',4-4 1 '`4,15*,{44 'f 7.,..401,4,-,,I,,., 1, ,,,tvt.s.F,,,ct 7,4-Ay-t--,:.,4.4.-I,-:,,f4- ENPHASE. -- ,,--,more at)out Enphase offerings visit enphasexam N., SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 11/411110000" BLUE RAVEN i 1 I i i 1 i j1/11q 0 *f a Plus, Sunmodule/ Plus SOL ARWORLD Sunmodule,/ SOLANWORLD 1 1403 N RESEARCH WAY,BUILDING J SWA 285 - 290 MONO BLACK ..,......." REAL VALUE SWA 285 - 290 MONO BLACK ..,..._..../ REAL VALUE OREM,UT 84097 800-377-4480 VVWVV B L UERAVEN SO LAR.COM PERFORMANCE UNDER STANDARD TEST CONDITIONS{.5TC)* CONFIDENTIAL-THE INFORMATION OA o sheet SWA al9 SWA 290 HEREIN CONTAINED SHALL NOT BE . ., . .. _,,,e‘a0.` -WA, USED FOR THE BENEFIT OF _ . ..IC.Wp ,Z90 Wp ANYONE EXCEPT BLUE RAVEN circuit votive. V, 15 2 v 111V SOLAR NOR SHALL IT BE ; . Maximum parer poi#War V,„ 11 0 v St 2 V DtSCLOSED IN VVHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS . Matt ensittornertr 1,, s s.i A St 60 A -.me-. - .1 I I 1 I ! 44"iirnitMPPIrTP?I',./C4"71"( • V DOA sutra RGANIZATION,EXCEPT IN CONNECTION WTH THE SALE AND 1'; 1 I • 1 . ' , Modateekteme 4. 110 I{ 17.3% USE OF THE RESPECTIVE I I EQUIPMENT,WITHOUT THE , $111,41.41/Mg ttlIP/AMP{P.,,j IrAer Able to 1 lN IthommUnd,,,,' 1.4 sir 104X,V1iPH,,Inir,itat 1 S WRITTEN PERMISSION OF BLUE . 1 PERFORMANCE AT SOO Vona,NOCT,AM 1.5 S siV:ii.i2:,S, SWAJ RAVEN SOLAR LLC. I . ' , t . : i • abonmsoriperwr NABCEP 36.2 v OO _ _. SV FCERTIFIED 4.- I Mmytmem porrerpone*error Moot theaft fumed V_,. I, ASV /SO A 19 9v tee A PV INSTALLATION .., , -----.-- i I Motitosaii parlor Wet torornt 1,,,,,, WA 717A , r • PROFESSIONAL I Mirof reauctson n trtmeney undo portal load rtmemoin al 25 X.At 200 Wire'.9A Di MI Of the 57C tflsoency row A/' I 4*mimed Scott Gurney tt a PV-01 1719-015868 PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION -,... ..-EI . ,sortiog Mese/*Sete ^ (( 41 Et gi CONTRACTOR. ?Mamma.,syfttm iv4taye St il/KC le9()V . k0 ..........,...• BR S FIELD OPS I 385.498.6700 3 . , fArrn1t1t/Of boast NMI I . 4 21) w,g--1 9.Ptnli^9,1"Pirtu'r 40 to YilS`C .440.70,4.03 erkign t000x 000 norwavoir T13 ps2 kronur Ard,64 psi upward vi"er, -kei Ill 410011NN Y107416 iv 1 ClUALITY BY SOLARWORLD - 01 Aiello t Mote 011 sgeytor tre pOdis*nward.44 estkm*4M 'my woe-zym.'...,,,--sley 4114/10.0.wolHastforci.f..Sat ottvi.,4K,kAtOrarM04.0 kVat Hat 080 Mt • 0 COS I'9. . od COMPONENT MATERIALS sollowotki. foundation Iii bola on mote than Orem of ongoing innovation,contirtuout optimisation end Ntehriology oxspottite,MI pruction ., Peps from silicon to modulo are established at our produetion$ites ensvoing the highttg possible quality for out customers.Our modules t*roe in feff$pt'mask 80 c., a variety et different sites and newer,making then suitable fin all global apefiCatIOns-born residential solar systents to terstaecale power plants. Crnytto.. Martor.2,11.1Wlint PIRC gi ,,„„ 6Meniiites ton 8 tt Irl 4'136 Inm x 11%rrtniJ .._ = 7-. front Tonnets-s1 sect veep with atit ON IMO) E''. *e' muttyines Jr* Imicirodwwwt,Wad ; L Front alert*iodate Amin" hegerd aieSthetsc desilps-enteely Katt solm module,horn SotacWorld Efficelt'Kik t ett technology tor the Mghest „al Ilk.the cells and Nome tot he module cornerS possible energy yields __—___. ____—_ PM r4ffliettot @Nem*tUL470 SI*eh Arophenol Lax 41111,11N Win istremely tough and stable,despite tts light weightPatented corner destan with integrated dramaste tor - cdolef.re pniorThinancr p.n.170sFyor 1 in handle Mud s up to int pst(8.5,kNim/) optioned sethd m eaning ,atilli111111 i- y 0 tit3'I9) da11111111 .010E1 'tested in extreme weather conch'ions hail impact tested High transmissive glass with antureffective coating ' inni DIMENSIONS/WEIGHT THERMAL CHARACTERISTICS il P AIM 1 Ili II II III And trsm ant co salt spray,frost,ansfrentia,dost and sand i Longterm safety and guaranteed top per lutt Hance ttittnti -1.11 tertgle Oh OS in POTS mod MXT 4,5*I Woven guarantee against Notspots end PILSiifree to 2 5.year linear performance warranty,20-year product i ______ _ IL(OZSO4 1 warranty Width 39 40 in poo mall -rC A. 007%it 1- IS 4 Mimi 1,..145 1r,m m0 rev, -0.29%A' ISO lith Wight ,1511 pa 0 so li 0.4.r 439%A Mr units wooded mt femoral ilsonli mended ot Potentinries ORDERING INFORMATION CERTIFICATES AND WARRANTIES a*,woe/0. Dm roan le{91730 IC 91715 1?!.17.0. — - CNIVNIN dailleilla Sortroaduir elos.SYSA Selmonennet MOWN Surtyrsedult Plus WY*290 mono black Eredass Warranty 20 Kafl 5 smear err tanname Conveyor* 25 remrs .......... MADE IN USA Ivoreffivtutrmwontymvetoo avowerkrovitilsooarwcoomwtolcr- ..k; OK/roawey hotwelian PwrOnnt-orwrowwbroeuedittorwizrourownet 6 Cs US sIMP47grtIVN6tt WWW soh rworld.q sa,com 5.040,41,041 Arnow"Inc resents tot ri pi to MN*241kwItIrotn/ro rhArogtro vrotnout rorotwo Om dais show g tompillevetttts trio+piplorewii.01101 VOW) SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 • BLUE RAVEN 4 3 2 1 ._.... ....-.....,.__ .-..__._..__.-.._ _...--_ _�.-. __._ __.. ........_...__..._.___ 1403 N RESEARCH WAY,BUILDING J 1 OREM,UT 84097 800-377-4480 VVVWV.BLUERAVENSOLAR.COM I ITEM NO. PART NUMBER DESCRIPTION QTY. CONFIDENTIAL-THE INFORMATION JB-1 Bod w/ E Z LOK POLYCARBONATE WITH UV HEREIN CONTAINED SHALL NOT BE 1 Y 1 USED FOR THE BENEFIT OF N TECHNOLOGY INHIBITORS ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE 2 JB 1 Lid w/Gasket POLYCARBONATE WITH UV 1 DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN 7/ 10 32 x 1" Phillips CONNECTION W TH THE SALE AND 3 pan head bolt USE OF THE RESPECTIVE ----"'N' EQUIPMENT,WITHOUT THE B [86.66mm] • 4 #8 x 1-1/4" Phillips 4 B KITTRAPERMISSION SOLAR L OFC. BLUE RAVEN LLC. 3.41 in pan head screw /[41.37mm] I BCEP 1.63in '� CERTIFIED �r 15-20 lbs-in PV INSTALLATION 01111 Torque Specification: PROFESSIONAL Certifications: ULStandard 1741, NEMA3R Scott N cR y / ` #PV-011719-015868 _ Weight (LBS): 1.3 lbs CONTRACTOR: 1304.80mrr +— —+ [198.37mm] C BRS FIELD OPS 12.00in I 7.81 in 385.498.6700 • I I I I --j , - 4' EZ Solar 1 L ,_ [24.81 mm] SLC, UT USA I f, 98in Phone (385) 202-4150 [77.09mm] y www•ersolarproducts.com A 3.041n A UNLESS OTHERWISE SPECIFIED: NAME DATE [ [183.97mm] DIMENSIONS ARE IN INCHES DRAWN _ .E 7.24in TOLERANCES: CHECKED TITLE: --- FRACTIONAL! V ANGULAR:MACH! REND_ ENGAPPR. EZ SOLAR TWPLACE ° [266.70mm] TWO PE DECIMAL THREE PLACE DECIMAL ! MFG APPR. 10.50in NTERPRE GEOMLIRC GA I I PROPRIETARY AND CONFIDENTIAL TOLERANCIIG'ER: COMMENTS: THE INFORMATION CONTAINED IN THIS - - MATERIAI - SIZE DWG. NO. REV ,DRAWING IS THE SOLE PROPERTY OF IR REPRODU.ANY , B �J V_1 THOIHEW IN PART ORASA WHOLE FINISH WITHOUT' THE WRITTEN PERMISSION or NE%I ASSY JSFD ON -.__. -....-... -1 RSERTCDMPANY NAME HERDR F - - - - ROHIBRED. APPIIGTION DO NOT SCALE DRAWING SCALE. 1:2 WEIGHT: SHEET 1OF.3i 4 3 2 1 SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 Nib IF" 4 3 2 1 BLUE RAVEN [170.73mm] I 1 6.721n 1403 N RESEARCH WAY,BUILDING J OREM,UT 84097 [19.81mm] [55.89mm] 0.78in 2.20in 80o-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION \ HEREIN CONTAINED SHALL NOTBE I (---------- \ USED FOR THE BENEFIT OF [57.94mm] ANYONESLAR NO SHALL LITBERAVEN ! 2.281n I!, DISCLOSED NOWHO ELOR IN PART TO OTHERS OUTSIDE RECIPIENTS B , ORGANIZATION,EXCEPT IN B CONNECTION WITH THE SALE AND J/� A [12.42mm] USE OF THE RESPECTIVE `` .30 f �j�� 0.49in / EQUIPMENT,WITHOUT THE 1 WRITTEN PERMISSION OF BLUE [6.60mm] RO 2h 3• W 1'•' ' i////l/// //// RAVEN SOLAR LLC. 0.26in •73• r ` �' J I • // / / I i i / I / ! l/ NABCEP CERTIFIED PV INSTALLATION [15.88mm] -® A ® SIONAL [304.80mm] 0.625in / ST:TT PROFESIIGS=1 > 12.00 i n / I #PV-011719-015866 [50.80mm] . _ [175.61 mm] / CONTRACTOR: _____ 2.00in 6.91 in BRS FIELD OPS 385.498.6700 [9.53mm] y [F 0 4- 0.38in • [5.55mm] _y f 0.22in L. , SECTION A-A SCALE 1 : 1 �._ .i Indent --Mi.. [57.94mm] F A _ [266.70mm] 2.28in A 10.50in _ _ UNLESS OTHERWISE SPECIFIED: NAME DATE , - _ - -- DIMENSIONS ARE IN INCHES DRAWN _ TOLERANCES: y -- - - FRACTIONALt CHECKED TITLE: } ANGULAR'MACH!, BEND! ENG APPR. TWO PLACE DECIMAL . .. EZ SOLAR THREE PLACE DECIMAL I- MFGAPPR. -... - INTERPRET GEOMETRIC G.A PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: COMMENTS: . THE INFORMATION CONTAINED IN THIS MA ERIAL SIZE .DWG. NO. REV DRAWING IS THE SOLE PROPERTY OfEZ R. ANY REPRODUCTION E R - -. FINISH B �J B_1 ANYS AWHOLE WITHOUT IN PART ORASAWHOF FTSOARTHEWRIREN NEXT- ASSY USED ON PERMIStroN OF EZ SOLAR IS PROHIBITED. - - APPLICATION DO NOT SCALE DRAWING ' SCALE:1:2 WEIGHT: ; SHEET 2 OF 3 1 . 4 3 2 1 SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0 BLUE RAVEN 4 3 2 1 1403 N RESEARCH WAY,BUILDING J .. ,. . ..._,,._..,... _..._.___..__....._. _..._.___..._....�.....W.__ -__..___... OREM.UT 84097 800-377-4480 WVWV.BLUERAVENSOLAR.C O M CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF . ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE OUTSIDE INSIDE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SECTION A-A EQUIPMENT,WITHOUT THE A F B WRITTEN PERMISSION OF BLUE B SCALE 1 :2 I RAVEN SOLAR LLC 0 ���� / NABCEP j; CERTIFIED 4\ P; ` -- RIOFESS ONVif' I `. Scott Gurney C- I I( 4 #PV-011719-0158 I 1 CONTRACTOR: 1 BRS FIELD OPS 385.498.6700 [198.37mm] 7.81 in 1 1 LI iN___:_iia_ • -- [3.18mm] 1 .13in LID OVERHANG Ate— [22.23mm] . [183.97mm] .88in 7.24in A A UNLESS OTHERWISE SPECIFIED: NAME DATE DIMENSIONS ARE IN INCHES DRAWN TOLERANCES:FRACTIONALS CHECKED TITLE: ANGULAR'MACH! BEND! ENG APPR. TWO PLACE DECIMAL 2 _ __. _...._ EZ SOLAR THREE PLACE DECIMAL ! MFG APPR IMERPRF GEOMETRIC CA. PROPRIETARY AND CONFIDENTIAL TOLERANCING PER: -- - " COMMENTS: THE INFORM SATHEOSOLEN OPROPERTYOf IN THIS MATERIAL • SIZE !DWG. NO. REV DRAWINGE2 SOLAR.ANY B J B-1 REPRODUCTION IN PART OR AS A WHOLE HNLSH WITHOUT THE WRITTEN PERMISSION OF NM ASSY USED ON <INSERT COMPA NY NAME HERE>IS - PROHISYED. APPLICATION DO NOT SCALE SCALE: 1:2 WEIGHT: SHEET 3 OF 3 I 4 ___ 3 2 ] SHEET NAME SPEC SHEET PAGENUMBER REVISION SS 0 ,N,„ 1�■ sFmFRITME 1 BLUE RAVEN (� 1 FRAME ' 1 403 N RESEARCH WAY,BUILDING J ■■ MICRORAIiTM INSTALLATION GUIDE : PAGE OREM,UT 84097 800-377-4480 WWW.BLU ERAVENSOLAR.COM p CONFIDENTIAL-THE INFORMATION I I I 1 .I 11 t— S "" ',,•"� HEREIN CONTAINED SHALL NOT BE I _ I USED FOR THE BENEFIT OF . IIANYONE EXCEPT BLUE RAVEN ' SOLAR NOR SHALL IT BE o, DISCLOSED IN WHOLE OR IN PART v - TO OTHERS OUTSIDE RECIPIENTS I 1 ' l ORGANIZATION,EXCEPT IN 1 CONNECTION WITH THE SALE AND USE OF THE IVE -< EQUIPMENT.WITHOUT THE .. I _ __ WRITTENL_ -- PERMISSION OF B � : RAVEN SOLAR LLC. ' �u I r �- NABCEP CERTIFIED I 4;f ti PV INSTALLATION +rg,. . ii E-W BONDING PATH: PROFESSIONAL ONAL Scott Gume E-W module to module bonding is accomplished #PV-011719-01588e t with 2 pre-installed bonding pins which engage CONTRACTOR: I on the secure side of the MicrorailTM and splice. BRS FIELD OPS 385 498 6700 1 —II I 1 1 I I I 1 t i t J 1 1 J 1 I 1 1 1 I I I 1 I I I 1 1 1 1 I I ( I I 1 1 I 1 I J I I 1 I l I 1 ( I ( 1 �'� 1 I 1 1 1 1 I I 1 1 1 I I I Star Washer is t° EE6L.',.t : :Ante Use Only Single Use Onty '�ireat�Inet�lcxd N-S BONDING PATH: T I; § T, �E N-S module to module bonding is 1 ,ha rt t duct.nr And accomplished with bonding clamp with 2 integral torque t the hallowing: TERMIINALTORQUFE. TERMINAL TORQUE, bonding pins, 4-6 Ze1r6. 351n-Lb Install Conductor end instzall Conductor and 8 ay 'iiu. 25 In-Ilan torque to the following: Marque to the following: 10.14AWG 20 n4ilas 4-14AWG: 35n-lbs 6-14 W °7ft-ltrs I � I LUG DETAIL & TORQUE INFO LUG DETAIL &TORQUE INFO LUG DETAIL & TORQUE INFO ;� '' mow. Raw Lay-In Lug (GBL-4DBT) Race Range Lug(SGB-4) Wiley WEEBLug (6.7) • 10-32 mounting hardware • 1/4"mounting hardware • 1/4"mounting hardware • Torque = 5 ft-lb • Torque = 75 in-tb • Torque = 10 ft-lb -nat.,r e,ttcJ{k ., ``-,. • AWG4-14-So lid or Stranded • AWG 4-14-Solid or Stranded • AWG 6-14-Solid orStranded TRIMRAIL BONDING PATH: NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION TrimraiL to module bonding is accomplished with System bonding is accomplished through modules.System grounding accomplished by attaching bonding clamp with integral bonding pin and bonding T-bolt. SHEET NAME a ground lug to any module at a location on the module specified by the module manufacturer. SPEC SHEET PAGE NUMBER REVISION SS 0 • Nor- ntertek AUTHORIZATION TO MARK BLUE RAVEN Total Quality.Assured, 1403 N RESEARCH WAY,BUILDING J This authorizes the application of the Certification Mark(s) shown below to the models described in the Producl(s) OREM,UT NOV Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization alsoapplies to multiple listee model(s) identified on the correlation pageof the USti BOO-377-44BDI epo pi VWWJ BLUERAVENSO AR.COM Report CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be USED FOR THE BENEFIT OF applied only al the location of the Party Authorized To Apply Mark. ANYONE EXCEPT BLUE RAVEN SOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS Applicant: Unirac. Inc Manufacturer: Cixi Emeka Aluminum Co. Ltd ORGANIZATION,EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE 1411 Broadway Blvd NE No. 688 ChaoSheng Road WRITTEN PERMISSION OF BLUE Address: Abuquerque. NM 87102 Address: Cixi City RAVEN SOLAR LLc Zhejiang Province 315311 Country: USA Country: China NABCEP Contact: Klaus Contact: JiaLiu CERTIFIED Tom Young Robin Luo PV INSTALLATION 505-462-2190 r86-15267030962 PROFESSIONAL Phone: S 505-843-1418 Phone: +86-1 3621 78 5753 01171 -01 M PV-cot Gurney FAX: NA FAX: NA CONTRACTOR: klaus.nicolaedis@unirac.com jia BRS FIELD OPS wan.cxymj.xym Small: toddg c@unirac.com Small: buwan.luo@cxymj,com 385.498.6700 Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Lake Forest, CA U.S.A. 'fl _f� �s.• Control Number: 5003705 Authorized by: 1 �+a►+AI`�`k JJ for Dean Davidson,Certificate anager Gus Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. l ire harmalaNn 10 MYI,,pled Pp rrdue..r,r1tt d prvkA►Gerd Ordro prr.A'dp.o.uvr In 1R rirll,valrrnaprrnemI hHwrri.InIrrlen.And dICede.P41H try dnpanllpalya 11,061.10 nor urged b 14 bane aid cWdlvu aI Ili.rlpsamrrl Meng MIAMI rP I.L.1+I.w en.Darr..c rug Ira':0 Ili Gbrr.n ttuarderrce er41.114 aprwemra,b wo lors.rr+isirre w Mlape vccawned q the use d ten Auea§r1W 4 kirk Only h 01erd n..1un{1d lo your.upre4 01 dstnb son el d.e kunmlrnm lo 1aiek and Peer wdr 0,1 .,Hv010 1J351 d 140411144 Ceraksalrrf rrrerk IMPOS010Ito Cord:ars lard oN l Ire apeossie a angle,tea cur 1L1i0010 leak Any rr71el ire 011r teem.RIM rer Pr aye a aO oneher ore of ale mod mane!.Ie03.H1 at WAC O MN MI ra'r4 O.rd in wiling try Imp pa Ile eat F Rory Apple art)roarer to rtrevve0,err ire 1w P104e d*memo appRprele grape PI I1re G0Iarmrn rlrt 01 rcerpv ear DV epreerros Uses Vs notice re Purposes or prOelZ r0 QdMry toot and m nal Wove Ire Caerll C1 Asir ae0pu01s Ng lrte respect IMerlek Testing Services NA Inc. 545 East Algonquin Road.Arlington Heights, IL 60005 Telephone 800-345-9A51 or 847-439-5667 Fax 312-283-1672 Standard(s): Mounting Systems. Mounting Devices. ClampingPRetention Devices, and Ground Lugs for Use with Flat- Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1I Product: Photovoltaic Mounting System, Sun Frame Microrail • Installed Using Unirac Installation Guide, Rev PUB2019MAR01 with Annex North Row Extension Installation Guide Rev PUB2019FE R20 Brand Name: Unirac Models: Unirac SFM SHEET NAME SPEC SHEET ATM for Report 1 t12393982L4X•002 Page 1 of 1 ATM Issued:9 Apr 2019 PAGE NLM0ER REVISION ED If 315 1"20-Apr-'TI Merreeury SS 0 �■ SUN & sLIDERs ; ���,�a r BLUE RAVEN ■ FRAME 1403 N RESEARCH WAY,BUILDING J le Ili MICRORAIIN INSTALLATION GUIDE : PAGE OREM,UT 84097 800-377-4480 WWW.BLUERAVENSOLAR.COM _ CONFIDENTIAL-THE INFORMATION �i HEREIN CONTAINED SHALL NOT BE \ INSTALL SLIDERS AND USED FOR THE BENEFIT OF ROOF ANYONE EXCEPT BLUE RAVEN illti. . ' - Iqllppo„ - ATTACHMENTS:. SOLAR NOR SHALL IT INBE UP-SLOPE DISCLOSED IN WHOLE OR PART Follow manufacturer instructions TooTHERsouTSIDEREGIPIENTs 1. ORGANIZATION EXCEPT IN for flashing installation procedures CONNECTION WITH THE SALE AND 111111%11111teil - USE OF THE RESPECTIVE I iiii1 �` %po. EQUIPMENT,WITHOUT THE WRITTEN EO PERMISSION RESPECTIVE BLUE VEN SOLAR LLG 11141 yrf :RcRINA BCEP- TIFIEDL__.u. ._._ PALLATION 1: ° AlSSIONAL PILOT HOLES: FLASHINGS: Scott Gurney Drill pilot holes for lag screws or Place fleshings Mod NS + 1" #PV-01 1 71 9-01 58 88 ..,,,,,„,„,„ -,:.-- OP structural screws (as necessary) at _ _ CONTRACTOR. marked attachement points _ B38 FIELD 00 385.498.6700 • • . • • / /� tow NOTE.if N-5 module edge is w+ithtn t"of the • r ` shingle course above,you have the option to Wit/ pivot t i orate slider at the attachment owes • • • • ■ to span the next course and cut shingle.s as _ l/ '� Cut Shingles as Required II : - r. ~,r Mod N5 + 1" '' , y Rotate Slider f �r ----fir , 2,, -- l INSTALL SLIDERS AND TRIMRAIL ROOF ATTACHMENTS: #I. ® ! It r stt��kl;t ELrwR •�>" • ��_ _Less Than 1"---,w•• - ;,; Insert fleshings per manufacturer instructions 1 diameter of 5/1. " .»1 `, f • Attach sliders to rafters L , - -1 —i---IF illki • Verify proper row to row spacing for module size (Mod NS+ 1 ) t *ram • Ensure that TrimrailTM roof attachments in each row have sufficient 1 ' I I I engagement with slider dovetails for proper attachment. , 1N DON-'S�ILOPE J Jr''V { SHEET NAME SPEC SHEET PAGE NUMBER REVISION SS 0