2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 13145 Southwest Ash Drive, Tigard, Oregon, 97223, United
City: Zip:
Owner's Name: Margaret (Peggy) Dahms Date: 03/25/2020
Contractor's Name: Blue Raven Solar CCB #: 227185
Design Parameters of the Property/Structure
If"Yes", does not
Is the installation qualify for the
Flood Hazard Located in a flood ❑ Yes
prescriptive path, follow
Area plain/flood way? p No OSSC or ORSC for
design requirements.
MI
Is the wind exposure Is If"Yes", qualifies for
Wind Exposure "C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
0 Yes the prescriptive path.
above
❑ No
1
I:/Building/Forms/Photo Voltaic-Checklist02-01-11.docx
Is the construction
material wood and does 0 Yes
Type of If"Yes", qualifies for
the construction qualify
Construction as"conventional light ❑ No the prescriptive path.
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. 0 Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. El Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Is the combined weight p Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
El
layout in accordance Yes If"Yes", qualifies for
with Section 305.4(3) of
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ❑ of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
of composition
shingle.
Is the roof mounted p Yes
Connections of solar assembly
the solar assembly connected to roof If"Yes",e iqpti e p for
to the roof framing or blocking ❑ No the prescriptive path.
directly?
2
L•Building/Forms/Phata V oltaic-Checklist02-01-11.docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metal panels If the width of the panel
Width of roofing is less than 18 inches,
panels? 18 inches or less qualifies for the
inches
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. '/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12" o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the 0 Yes If"Yes", qualifies for
solar modules module to the roof the prescriptive path.
surface. ❑ No
3
I:Building/Forms/Photo V oltaic-ChecklistO2-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing (rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: J in ko
Model Number: 315
Listing Agency: CSA