Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
PHOTOVOLTAIC ROOF MOUNT SYSTEM RECLJVED AR 2 5 2020 ea ELEMENTAL 31 MODULES-ROOF MOUNTED - 8.99 kWDC, 6.67 kWAC CITY OF TIGARD ENERGY BUILDING DIVISION 11049 SW BLACK DIAMOND WAY, TIGARD, OR 97223 USA 1339 SE BTH AVE, PORTLAND.OR 97214 --- _ - - - Phone-(541)316-5786 PROJECT INFORMATION: SYSTEM SUMMARY: GOVERNING CODES: conhacro4 OR CCS#:185141 OWNER: KATHRYN GIBBS SYSTEM SIZE(DC): 8.99 KW 2017 NATIONAL ELECTRICAL CODE(NEC) REVISIONS ADDRESS: 11049 SW BLACK DIAMOND WAY, TIGARD, OR 97223 SYSTEM SIZE (AC):6.67 KW 2019 OREGON FIRE CODE(OFC) COUNTY: WASHINGTON COUNTY (N)31 -HYUNDAI HID-S29ORG BK (290W) MODULES 2019 OREGON MECHANICAL SPECIALTY CODE (OMSC) DESCRIPTION DATE REV APN: R2032104 (N)31 -ENPHASE M215-60-2LL-US-S22 MICRO-INVERTERS 2017 OREGON RESIDENTIAL SPECIALTY CODE (ORSC) FIRST DRAFT 02/20/2020 COORDINATES: 45.4418679,-122.790722 (N)Q BOX PV QMQB-J1 B 2017 OREGON PLUMBING SPECIALTY CODE(OPSC) _ CUST. PHONE: N/A (E)200A MAIN SERVICE PANEL WITH 200A MAIN BREAKER, PGE BUILDING DATA: SINGLE FAMILY RESIDENTIAL APPLICABLE CODES: 2017 OESC&2019 OSSC VALIDITY OF PERMIT MAX, MIN TEMP: 37°,-8° DESIGN CRITERIA: FINANCING: N/A THE ISSUANCE OF A PERMIT SHEET INDEX Electrical Contractor CLIMATE DATA SOURCE: PORTLAND/HILLSBORO OFFICE COPY WIND SPEED: 96 MPH (ASCE7-16)RISK CATEGORY: II BASED ON CONSTRUCTION DOCUMENTS AND OTHER PV-0 COVER SHEET WIND EXPOSURE CATEGORY: B PV-1 OVERALL SITE PLAN DATA SHALL NOT PREVENT GENERAL NOTES: GROUND SNOW LOAD: 25 PSF PV-2 ROOF PLAN WITH MODULES ROOF TYPE:ASPHALT SHINGLE THE CODE OFFICIAL FROM PV-3 BRANCH LAYOUT FFICE TJT 1. PV SYSTEMS AND SUPPORTING STRUCTURE SHALL COMPLY NUMBER OF LAYERS:-01 REQUIRING THE CORRECTION PV-4 FRAMING PLAN &SECTION DETAIL WITH REQUIREMENTS OF 2017 OESC&2019 OSSC. ROOF FRAME:2"X8"PRESCRIPTIVE RAFTERS 24"OC OF ERRORS.ORSC 105.4 PV-4A ATTACHMENT DETAIL 2. 3111.3.2-PV RACKING AND ATTACHMENTS SHALL BE UL 1703 STORY: TWO PV-5 THREE LINE DIAGRAM PROJECT NAME CERTIFIED. LIABILITY PV-6 ELECTRICAL CALCULATION& 3. 3111.3.4-PV SYSTEM SHALL HAVE A FIRE CLASSIFICATION The Cityof Tigard Approved ELECTRICAL NOTE THAT IS EQUAL TO OR GREATER THAN THE ROOF ASSEMBLY g rd and its pp plans PV-7 WARNING LABELS REQUIRED BY OSSC SECTION 1505.1. employees shall not be shall be on job sue. LU < 4. 3111.4.3-3111.4.7-PV LAYOUT SHALL NOT RESTRICT EGRESS, LIGHT VENTILATION, OR ROOF DRAINAGE REQUIREMENTS. responsible for discrepancies 0 Z 5. 3111.4.8.1 -GENERAL PATHWAY REQUIREMENTS: Which may appear herein. LLJ 0 • 36"WIDE PATHWAY SHALL NOT BE REQUIRED ON a Z � "l.acys CP.1.1 �f ARRAY LOCATIONS o N ' w STRUCTURES WITH A PV ARRAY AREA OF 1,000 SF OR LESS CITY OF TIGARD �' cp INSTALLED ON A ROOF WITH A SLOPE THAT EXCEEDS 2:12 AND REVIEWED FOR ODE COMPLIANCE I, .a Li] Q N WITH AN INTERSECTING ADJACENT ROOF AND WHERE NO Washington yquare9 9 „ q Q M SECTION IS LARGER THAN 150 FEET MEASURED IN LENGTH OR Approved: [ ,c .,• ct WIDTH. OTC: ? �. m Y 0 CNI • WHERE PV ARRAY DOES NOT EXCEED 25%AS MEASURED IN !— PLAN VIEW OF TOTAL ROOF AREA OF A STRUCTURE,A Permit#: Crescent Grove Cemetery . a _ ` m U 0 — YY�ST 7.0— 0�0�17 E > " Q z MINIMUM OF 12" UNOBSTRUCTED PATHWAY SHALL BE C7 J Z J MAINTAINED ALONG EACH SIDE OF ANY HORIZONTAL RIDGE. Address: \0L( 4 � [. pJ, • +3yt'1 , m Q — rL 'V p a H. • WHERE THE SOLAR ARRAY EXCEEDS 25%AS MEASURED IN Suite #. it-.A,- d C1r w i " • 11049 Southwest } o < D PLAN VIEW OF TOTAL ROOF AREA OF THE STRUCTURE,A / p+ nn > i— MINIMUM OF ONE 36"UNOBSTRUCTED PATHWAY SHALL BE P} k Date: 3( ,l 2DZG # it',„:,:;\,,,:,• B4ack V. . f and a I -PROVIDED IN ADDITION TO A MINIMUM 12"UNOBSTRUCTED y _ tGasrrepub and Grili Lion 4 a HALONG EA. SIDE OF ANY HORIZONTAL RIDGE. Q 1 1w6. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED WOOD , , rCONSTRUCTION WITH 2"X8"PRESCRIPTIVE RAFTERS @ 24" o4. O.C. REFER TO ALLOWABLE SPAN REQUIREMENTS IN TABLE `" " IFLY 9 7. 3111.4.8.5.1 -DISCONNECTS,J-BOXES, COMBINER BOXES OR Englewood a t` J PROJECT GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED PATHWAY Park 3 �.8s� E `' 4 20-1123 OR CUTOUT. 11049 Southwest a 8. 3111.5.3.1 -TOTAL SYSTEM WEIGHT SHALL NOT EXCEED 4.5 Black Diamond Way J�` •;.,a. SHEET NAME PSF. PV MODULES AND RACKING SHALL BE DIRECTLY Rose City Futsal WEST 9 , - ATTACHED TO ROOF FRAMING AS SHOWN IN PV-2. s , --, COVER SHEET ATTACHMENT SPACING WILL BE 48"O.C. MAX,AND WHEN s� 0 ". x ' ATTACHMENT LOCATED WITHIN 3'OF ROOF EDGE, HIP, EAVE, PROJECT SITE H;gh snorts ,� RIDGE SHALL BE 24"O.C. MAX. �I SHEET SIZE 9. 3111.5.4-MAX MODULE HEIGHT< 18"OFF ROOF SURFACE. .. Ne 4 ,; ,x Nw:h C41,03r -._. „•4c ANSI B 4t' 'COVER SHEET VICINITY MAP "1/4, AERIAL VIEW ^ SHEET NUMBER SCALE: NTS. SCALE:NTS W SCALE:NTS W PV-0 ©Copyright Elemental Energy 2020. Ail rights reserved. PROJECT DESCRIPTION: -0 NOTE: *CHECK WITH 31*290 HYUNDAI HID-S290RG BK(290W)MODULES (E) BACK OF RESIDENCE �(j• N o FOR ACCURATE PROPERTY OLOCATION.tAND SURVEYOR ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES OPE' ELEMENTAL SYSTEM SIZE: 8.99 DC QR/ I mm ENERGY 6.67 AC -Al ? -/ 1 -I 1339 SE 9TH AVE, EQUIPMENT SUMMARY / I r PORTLAND,OR97214 31 HYUNDAI HID-S29ORG BK(290W)MODULES I Z Phone-(541)316 5786 31 ENPHASE M215-60-2LL-US-S22 INVERTERS .,./ I m Contractor#OR CC13# 195141 . ./ I REVISIONS -- _18.04' ........0**'.' -/ DESCRIPTION DATE REV FIRST DRAFT 0212012020 I I I O i (p Electrical Contractor 16'-6" I I 1 PROJECT NAME ROOF#1 - I (15)HYUNDAI HID-S29ORG BK 1 E (290W)MODULES I. 0 I �- W Q i 0 c ' 00 Z _ I O_ oI ❑ I i O Z c1) COI ' O (N' d- W t (n 0 0 ROOF#3 SUNEYE LOCATION I \ ❑ I (06)HYUNDAI HID-S29ORG BK Q N 0_ (E)MAIN SERVICE PANEL 200A I O ' (290W)MODULES O O RATED,WITH 200A MAIN BREAKER I `� coY }' (INTERIOR WALL) ROOF#2 - EtI I (06)HYUNDAI HID-S29ORG BK CD J Z - (E) UTILITY METER(EXTERIOR WALL) I (290W)MODULES (N)AC COMBINER PANEURSD -� 1 z COc.D0_ D I _ Q (EXTERIOR WALL) `N i Ct I— `� W — I (E) FENCE II < C I n r ROOF#4 —___ 2 -11 Y co HYUNDAI HID-S29ORG BK . (290W)MODULES 1 �, PROJECT �W I I 20-1123 QO I �- (E)TREE EV OUTLET Z I EXISTING I SHEET NAME H1 DRIVEWAY b I (N I OVERALL SITE PLAN CLUJ1 0 I IY I I SHEET SIZE a-L--------------___--------------1_1 ANSI B PROPERTY LINE -60.01 ' 1 OVERALL SITE PLAN ^ SHEET NUMBER J SCALE: 3/32"=1'-0. SW BLACK DIAMOND WAY PV-1 (E) FRONT OF RESIDENCE ©Copyright Elemental Energy 2020. All rights reserved. MODULE TYPE, DIMENSIONS & WEIGHT ROOF DESCRIPTION NUMBER OF MODULES=31 MODULES AREA OF NEW AREA OF ROOF TYPE ASPHALT SHINGLE ELEMENTAL MODULE TYPE= HYUNDAI HID-S29ORG BK(290W)MODULES ARRAY ROOF(PLAN VIEW) TOTAL ROOF AREAee MODULE WEIGHT=39.7 LBS/18.0 KG. (Sq.Ft.) (Sq.Ft.) COVERED BY ARRAY% ROOF PRESCRIPT! PRESCRIPTIVE ENERGY ROOF TILT AZIMUTH VE RAFTERS RAFTERS MODULE DIMENSIONS= 65.95"X 39.40"= 18.04 SF UNIT WEIGHT OF ARRAY=2.20 PSF 559 2480.96 23% #1 SIZE SPACING 1339 SE 8TH AVE, 34° 270° 2"X8" 24"O.C. PORTLAND.OR 97214 GENERAL NOTES: 23% ROOF AREA(ARRAY>25%OF ROOF AREA) #2 34° 180° 2"X8" 24"O.C. Phone-(541)316-5786 1. CONDUIT IS DIAGRAMMATIC.FINAL ROUTING TO BE DETERMINED BY INSTALLER. - #3 34° 180° 2"X8" 24"O.C. Contractor#OR CC8#:195141 2. SUNEYE SHOT S1 WAS COLLECTED IN THE SPECIFIED LOCATIONS AND #4 CORRESPONDS TO KATHRYN GIBBS RESIDENCE SHADE REPORT"PDF 34° 180° 2"X8" 24"O.C. REVISIONS DESCRIPTION DATE REV X65.95" X FIRST DRAFT 02120\2020 -c (E) BACK OF RESIDENCE 0 o; 0, 16'-11" PHOTOVOLTAIC MODULESX ' 1'-11" Electrical Contractor HYUNDAI HID-S29ORG BK - (290 W)MODULES ) / 12"FIRE PATHWAY (N)(49)FLASHKIT SFM SLIDER COMP DARK is, o (N)(4)SFM ATT SPLICE 8" r �__�_ ///;, (N)(20)SFM SPLICE 6.5" 6'-11 6'-8" 18'-2" © - ,Y / PROJECT NAME ROOF#1 \--- , +a_ ° i o (15)HYUNDAI HID-S29ORG BK(290W) 0 MODULES \_ • + 01 /r i% 4/, ,/,' \ >' e(E)MAIN SERVICE PANEL 200A I I + i/ Ill Q RATED,WITH 200A MAIN BREAKER 1t V (INTERIOR WALL) II _ _ _ } W p a Z M (E) UTILITY METER(EXTERIOR WALL) F 1(-7 �j , N V" (N)AC COMBINER PANEURSD N .A0 m ROOF#3 w O� (EXTERIOR WALL) T (06)HYUNDAI HID-S29ORG BK(290W) Ct Q a) CV a r MODULES 3 IYM 1- .---- - - ..►- coY + • e ROOF#3 CO 0 Q W I— M T TILT-34° ( J Z ROOF#1 2 ;-- t * AZIM.-180° Q a I TILT-34° m o ZCO Ur Q ROOF -270° „ r_ ROOF#2 .r • Z a) (06)HYUNDAI HID-S29ORG BK(290W) r - 1 - - -- ROOF 4 < CD MODULES - I AZIM.-180° r' X 5'-6„ 2Z-3" - X 6'-0" X ROOF#4 LEGEND TILT-34° -- - AZIM.-180° UM UTILITY METER MN SFM SPLICE 6.5" 1 PROJECT EV OUTLET _ (E)(38)SFM TRIMRAIL UNIV CLIP W/HDW MSP VVIT 20MA AN SERVICE PANEL ® SFM MICRORAIL 2" 20-1123 WITH 2O0A MAIN BREAKER ROOF#4 SHEET NAME (04)HYUNDAI HID-S29ORG BK(290W) RSD RAPID SHUTDOWN SFM ATTACHED SPLICE 8" MODULES ROOF PLAN WITH (N)(10)SFM TRIM SPLICE DRK CB ENPHASE COMBINER BOX • SFM TRIM ATTACHMENT SW BLACK DIAMOND WAY _- • MODULES (N)(31) FLASHKIT SFM TRIM COMP DARK JB JUNCTION BOX SFM TRIM UNIV CLIP (E) FRONT OF RESIDENCE CHIMNEY min FULL TRIM SECTION SHEET SIZE 0 PIPE VENT CUT TRIM SECTION ANSI B PROOFPLAN WITH MODULES ATTIC VENT TRIM SPLICE SHEET NUMBER 1 CONDUIT RUN SCALE: 3/32" = 1'-0" � PV-2 ©Copyright Elemental Energy 2020. All rights reserved. (31) HYUNDAI HID-S29ORG BK MODULE .r 65.95" ,r (31) ENPHASE M215-60-2LL-US-S22 MICROINVERTERS (E) BACK OF RESIDENCE b (3, ELEMENTAL' (1) BRANCH OF 16MODULES & ENERGY M (1) BRANCH OF 15MODULES Hc CONNECTED IN PARALLEL PER BRANCHES PHOTOVOLTAIC MODULES 1339A PORTLAND,LAND,OR 97214 HYUNDAI HID-S29ORG BK Phone-(541)316-5786 BILL OF MATERIALS (290 W)MODULES contractor*OR CCB#r 195141 EQUIPMENT QTY DESCRIPTION 12"FIRE PATHWAY REVISIONS O DESCRIPTION DATE REV SOLAR PV MODULE 31 HYUNDAI HID-S29ORG BK 290(290W)MODULES / /l FIRST DRAFT 02/2012020 INVERTER 31 ENPHASE:M215-60-2LL-US-S22 INVERTERS TRIM 18 SFM TRIMRAIL 66 UNIV DRK TRIM SPLICE 10 SFM TRIM SPLICE DRK ROOF ATTACHMENT 31 FLASHKIT SFM TRIM COMP DARK Electrical Contractor MICRORAIL 45 SFM MIRCRORAIL 2" ROOF#3 MICRORAIL ATT 4 SFM ATT SPLICE 8" II MODULES6) HYUNDAI HID-S29DRG BK(29GW) SPLICE MICRORAIL SPLICE 20 SFM SPLICE 6.5" ❑ a — (31) ENPHASE M215-60-2LL-US-S22 MICRO INVERTERS FLASHING 49 FLASHKIT SFM SLIDER COMP DARK Iliv -''/, / 2i/'/: /Y. / // j ////////// BRANCH#2 PROJECT NAME / I ROOF ATTACHMENT 11 SFM TRIM BONDING CLAMP 1. I it • LH CLIP 38 SFM TRIMRAIL UNIV CLIP W/HDW I I NN I `'/ j1 /�- GROUNDING LUG 4 ILSCO LAY IN LUG(GBL4DBT) �- Iill Iji / �\ — LLJ N-S WIRE CLIP 19 SFM N/S BONDING CLAMP • I I 1 /1 L.1�2 /// \ Z END CAP 11 SFM TRIM END CAPS I ■ i I I I / \\ , ti o , ■ I ■ MI -� cf Q a) N Cl I I • // / o IY Cr i mQoI- BRANCH#1 �' \tN OD Z Q I- d ROOF#1 \N CD Q D (15)HYUNDAI HID-S29ORG BK(290W) 1 (1 ' MODULES ROOF#2 /// Q O (06) HYUNDAI HID-S29ORG BK(290W) MODULES H N----a-- --.-- ---E------ S ROOF#4 — (04) HYUNDAI HID-S29ORG BK(290W) PROJECT MODULES 20-1123 SW BLACK DIAMOND WAY SHEET NAME (E) FRONT OF RESIDENCE BRANCHING LAYOUT SHEET SIZE ANSI B , LAYOU SHEET NUMBER 1 (fBRANCHING SCALE: 1/8" =1'-0" PV-3 iy-• ©Copyright Elemental Energy 2020. All rights reserved. • / 10'-6" / 5'-8" PRESCRIPTIVE CODE FOR \ MAX SPAN 2"X8"@24" 12'-4' eeRIDGE BEAM ELEMENTAL j RAKE „ EAVE SOLAR MODULE -- 2"x8" RAFTERS @ 24"O.C. ENERGY. 1-T-4 1339 SE 8TH AVE, in M // 7� y PORTLAND,OR 87214 ?Ni D Phone-(541)316-5786 � y P� j Contractor#OR CCB#:195141 i7 e J Q 7 PURLIN BRACE IIIRI DESCRIPTION DATE REV ;1111111G)11.1N11114111 V Po FIRST DRAFT 02\20\2020 00 O /110111:31kk< 2"x10"CEILING JOIST @ 24"O.C.ni TOP PLATE in 7 \ Electrical Contractor - 1aL ArdnitiMaid EAVE elti 4 6 22 3„ 7, 0 liar BEARING WALL PROJECT NAME M LLI FRAMING PLAN U Q SCALE: 1/16" = 1'-0" Z \ \ \ LLI ❑ SECTION DETAIL FOR ROOF #1 ❑ z M SCALE: 3/16" =1'-0" W 0 p SOLAR MODULE Q CT) CVCL 2"x8" RAFTERS @ 24"O.C. - RIDGE BOARD — m-I l -._D\ RIDGE BEAM SOLAR MODULE s 9 a RIDGE BEAMty co l ❑ Li-O N O 4# �/' 2"x8" RAFTERS @ 24"O,C.OLAR MOD\E 2-10" my 1'-10" CO U Q 2'x8" RAFTERS @ 24" O.C. } m� I rI 4 J i Z-7Q �� PURLIN BRACE — PURLIN BRAG 384° CC iiiik Aii_iiiiii N < JOIST @ 24 O.C. \— - 2"x10"CEILING 2 x10 CEILING TOP PLATE r ' 2"x10" CEILING N TOP PLATE JOIST @ 24"O.C. TOP PLATE JOIST @ 24"O.C. PROJECT zo _ 20-1123 SHEET NAME FRAMING PLAN & 7 \ 7 I a) -11111111 BEARING WALL BEARING WALL BEARING WALL SECTION DETAIL }, SHEET SIZE ANSI B SHEET NUMBER "SECTION DETAIL FOR ROOF #2 PV4SECTION DETAIL FOR ROOF #3 P�,SECTION DETAIL FOR ROOF #4 PV-4 gypSCALE: 1/8" =1 -0' SCALE: 1/8 =1 -0 SCALE: 114" =1 -0 G Copyright Elemental Energy 2020. All rights reserved. ea ELEMENTAL SUNFRAME MICRORAIL 2" ENERGY 1339 SE 8TH AVE, PORTLAND,OR 97214 Phone—(541)316-5786 Contractor#OR CCS#:195141 SFM ATTACHED SPLICE 8" REVISIONS ',0 DESCRIPTION DATE REV — FIRST DRAFT 1 0212012020 it j ASPHALT SHINGLE ROOF Electrical Contractor 2" X 8" PRESCRIPTIVE RAFTERS PROJECT NAME @24" O.C. W < Z W ❑ PV MODULE ❑ Z CO N V' W CO c\i� �W CD MODULE CLIPAdllPl rx LU Q N a TRI-DRIVE NUT m N >_ CO U p � � q ..A.t,4 0 m Q a H #C �� FLASHKIT SFM TRIM } ?) Q D TRIM RAIL - CK a) 4 •Wli _ a) T-BOLT ASPHALT SHINGLE ROOF O SFM TRIM ROOF ATTACHEMENT PROJECT 20-1123 „ilia, iiille.:_____ — 2" X 8" PRESCRIPTIVE RAFTERS SHEET NAME @ 24" O.C. ATTACHMENT DETAIL -SHEET SIZE ANSI B ATTACHMENT DETAIL SHEET NUMBER \ I 2 SCALE: NTS. PV-4A © Copyright Elemental Energy 2020. All rights reserved. • SYSTEM SIZE: INTERCONNECTION AC OUTPUT CURRENT ACCORDING TO ART.690.8(B)(1) 27.9 Amps 31 x HYUNDAI HID-S29ORG BK=8.99kW 120% RULE- NEC 705.12(D)(2)(3)(b) NOMINAL AC VOLTAGE 240 Volts 31 x ENPHASE M215-60-2LL-US-S22=6.67kW THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) ee ELEMENTAL UTILITY FEED + SOLAR BACKFEED ENERGY 200A 40A240A (31) HYUNDAI HID-S29ORG BK MODULE + = GENERAL NOTES: (31) ENPHASE M215-60-2LL-US-S22 MICROINVERTERS BUSS RATING x 120% 1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL PORTLAND.OR97214 200A x 120% =240A LOCAL OR NATIONAL CODE REQUIREMENTS AND Phone-(541)316-5786 (1) BRANCH OF 16MODULES & ` EQUIPMENT INSTALLATION INSTRUCTIONS. Contractor##OR CCB#;195141 (1) BRANCH OF 15MODULES 2. SEE PV-7 FOR LABELING REQUIREMENTS CONNECTED IN PARALLEL PER BRANCHES REVISIONS DESCRIPTION DATE I REV FIRST DRAFT 0212012020 TO UTILITY GRID Electrical Contractor Lt L2N M* Envoy-S (N)100A AC COMBINER PANEURSD, NEMA-3R,120/240V,im BI-DIRECTIONAL UTILITY 16 MICRO-INVERTERS IN BRANCH CIRCUIT#1 0 METER 1-PHASE,3-W, 120V/240V • • • - PROJECT NAME (E)MAIN SERVICE PANEL, lLari / I l�/ I ll�' 200A RATED,120/240V I I -"'-1V/ I (N)Q BOX PV " ) 4�, 1 OMQB-J1 B 15A (N)40A PV BREAKER 200A d- N W Q 6 0 0 U C Z E - - I -1 20A (E)MAIN BREAKER TO W Z co 15 MICRO INVERTERS IN BRANCH CIRCUIT#2 40A HOUSE 240V,200A/2P r 1' ; L1 • °— INSIDE THE HOUSE - 0 N •�O L ,1 �.1 ( r 11 j -1 1 . . . �7 L 20A L2 0 I W .c I-- r 0 ( i4t , � N N ly Q 0) CV 0- `N':" t$iYti"i'' N i i T'Y'f 3 �..TyF' T G 71 N M ii r 1, j A, H I G G ! I 1 ' __ L ' (3)#8 AWG THWN-2 _GEC Q W Z* J (1)#8 AWGW THN-2 GND GROUNDING Z CO < IL I- IN 3/4"PVC OR EMT Q 31 ENPHASE M215 60-2LL-US-S22 (2)ENGAGE CABLE (4)#10 AWG THWN-2 CONDUIT RUN ELECTRODE SYSTEM MICROINVERTERS(240V) (4)#12 AWG TRUNK CABLE (1)#12 AWG THWN-2 GND W (n (LOCATED UNDER EACH PANEL) (1)#6 BARE COPPER GND IN 3/4"EMT OR NMB ROMEXI°\— CONDUIT RUN I- O BRANCH TERMINATOR VOLTAGE DROP CALCULATIONS o E-TERM-10(TYP.) WIRE RUN #OF MODS V(VOLTS) I(AMPS) L(FT) VD** VD(%) WIRE SIZE* RACEWAY BRANCH#1(MODULE)TO Q BOX 16 240 14.4 50 2.29 0.95% 12 AWG FREE AIR PROJECT BRANCH#2(MODULE)TOO BOX 15 240 13.5 35 1.50 0.63% 12 AWG FREE AIR 20-1123 Q BOX TO AC COMBINER 16 240 14.4 35 1.01 0.42% 10 AWG 3!4"EMT/NMB ROMEX SHEET NAME Q BOX TO AC COMBINER 15 240 13.5 35 0.94 0.39% 10 AWG 3/4"EMT/NMB ----- ROMEX ELECTRICAL LINE AC COMBINER TO MSP 31 240 27.9 8 0.28 0.12% 8 AWG 3/4"PVC OR EMT DIAGRAM MAX VOLTAGE DROP: 1.49% SHEET SIZE WORST CASE VALUES _ ANSI B Worst Isc=Max(9.6A,9.74A)=9.74A ( ELECTRICAL LINE DIAGRAM Worst Voc= Max(43.65V,38.13V)=43.65V SHEET NUMBER I jSCALE: NTS PV-5 ©Copyright Elemental Energy 2020. All rights reserved. SOLARMODULESPECIFICATIONS AC CONDUCTOR AMPACITY CALCULATIONS: MANUFACTURER/ HYUNDAI HID-S29ORG BK 290 FROM JUNCTION BOX TO COMBINER BOX: ee ELEMENTAL MODEL# (290W)MODULES AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT ENERGY VMP 31.9V PER NEC 310.15(B)(2)(c) +27 IMP 9.2A EXPECTED WIRE TEMP(In Celsius) 37+27=59° 1339 SE 8TH AVE, VOC 39.6V TEMP.CORRECTION PER TABLE(310.16) 0.71 PORT- ND,OR 97214 Phone hone (541)316-5786 ISC 9.7A NO.OF CURRENT CARRYING CONDUCTORS 4 Contractor#OR CCB#:195141 MODULE DIMENSION 65.95"L x 39.40'W x 1.3"D(In Inch) CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 0.8 CIRCUIT CONDUCTOR SIZE 10 AWG REVISIONS DESCRIPTION DATE REV INVERTER SPECIFICATIONS CIRCUIT CONDUCTOR AMPACITY 40A FIRST DRAFT 02120\2020 MANUFACTURER/MODEL# ENPHASE M215-60-2LL-US-S22 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) NOMINAL AC POWER 215KW18A - _ 1.25 XMicro-Inverters(Max.String Length)X Max Output Current NOMINAL OUTPUT VOLTAGE I 240 VAC DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 NOMINAL OUTPUT CURRENT 1 0.9A TEMP.CORRECTION PER TABLE(310.16)X 22.72A CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)X Electrical Contractor AMBIENT TEMPERATURE SPECS CIRCUIT CONDUCTOR AMPACITY I'RECORD LOW TEMP _8° Result should be greater than(18A)otherwise less the entry for circuit conductor size and __ ampacity AMBIENT TEMP(HIGH TEMP 0.4%) 37° - - ROOFTOPTEMP 59° AC CONDUCTOR AMPACITY CALCULATIONS: CONDUCTOR TEMPERATURE RATE 90° FROM COMBINER BOX TO MSP: PROJECT NAME MODULE TEMPERATURE COEFFICIENT OF VOC -0.31%/°C No.OF INVERTER 26 EXPECTED WIRE TEMP(In Celsius) 37° TEMP.CORRECTION PER TABLE(310.16) 0.91 w Q NUMBER OF CURRENT i NO.OF CURRENT CARRYING CONDUCTORS 30 PERCENT OF CARRYING CONDUCTORS IN CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 1 Z VALUES EMT w .80 4-6 I CIRCUIT CONDUCTOR SIZE 8 AWG z co .70 7-9 CIRCUIT CONDUCTOR AMPACITY 55A - O N 'j w .50 10-20 CO ti CD REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) Q D7 fNO a. 34.88A co O 1.25 X TOTAL NO.OF INVERTER X MAX INVERTER OUTPUT CURRENT Cl) DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 CO U TEMP.CORRECTION PER TABLE(310.16)X 36.4A Q CL 1* J CONDUIT FILL CORRECTION PER NEC 310.15(6)(2)(a)X 0 J Z CIRCUIT CONDUCTOR AMPACITY z1221.. 6 DI- Result should be greater than(34.88A)otherwise less the entry for circuit conductor size > , and ampacity CL 1 CD i- d- 0 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. CALCULATIONS NOTES: PROJECT 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET 1. WIRE SIZES INCLUDE DE-RATING FACTORS SUCH AS AMBIENT TEMPERATURE AND MORE THAN 3 CURRENT CARRYING CONDUCTORS ENVIRONMENT. IN CONDUIT. 20-1 1 23 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY 2. BRANCH CABLE VOLTAGE DROP AND LENGTH DATA FROM MICRO INVERTER MANUFACTURER.LENGTH FROM BRANCH TO SOLADECK TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP,OR VALLEY. INCLUDED. SHEET NAME 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL 3. WHERE AC UNGROUNDED CONDUCTORS ARE INCREASED IN SIZE, EGC SHALL BE INCREASED IN SIZE PROPORTIONATELY ELECTRICAL COMPLY WITH NEC 110.26. ACCORDING TO THE CIRCULAR MIL AREA OF THE UNGROUNDED CONDUCTORS, CALCULATION & 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL ELECTRICAL NOTE APPLICABLE CODES AND STANDARDS. 6.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,THE SHEET SIZE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. ANSI B 7.)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. SHEET NUMBER 9.)MODULE O GBL SUPPORT -4DBT LAY-IN LUG. BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG ORILS PV-6 © Copyright Elemental Energy 2020. All rights reserved. ee ELEMENTAL DO NOT RELOCATE THIS = BRANCH#1 DISCONNECT N OVERCURRENT DEVICE 240VAC 14.4 AAC WARNING:DUAL POWER SOURCES PRESENT. \ — ♦ I 7540 WATT PHOTOVOLTAIC ARRAY LOCATED ON ROOF. 1339 5E 8TH AVE, PORTLAND,OR 97214 LOCATION: AC DISCONNECT QUANTITY:1 LOCATION: COMBINER PANEL QUANTITY:1 AC DISCONNECT LOCATED IN HOUSE ELECTRICAL PANEL Phone-(541)316-5786 Contractor#OR CCB#:195141 I 3„ LOCATION:AT METER QUANTITY:1 REVISIONS X / 1 1/2 ,Jr DESCRIPTION DATE REV - \ \ FIRST DRAFT 0212012020 BRANCH#2 DISCONNECT N TWO POWER SOURCES PRESENT.SECOND 240VAC 13.5 AAC .= SOURCE IS A PV ARRAY.AC DISCONNECT - - \ LOCATED IN HOUSE ELECTRICAL PANEL. LOCATION: COMBINER PANEL QUANTITY:1 - Electrical Contractor SOLAR PV SYSTEM ' LOCATION: INTERCONNECTION PANEL QUANTITY:1 EQUIPPED WITH 5.25" RAPID SHUTDOWN PROJECT NAME /LL�J Q RAPID SHUTDOWN SWITCH W Z CO SOLAR PV SYSTEM Z1e o o N o LJJ I in in(yQ0) N a m O N } LOCATION: RSD INITIATION DEVICE QUANTITY:1 fb 0 (- TURN RAPID SHUTDOWN Q 5 z SWITCH TO THE "OFF" I z m - Q j POSITION TO SHUT = 0) )r 2 ,' ` DOWN PV SYSTEM AND o REDUCE SHOCK HAZARD CAUTION: 1 1/2 ,A • PHOTOVOLTAIC SYSTEM _ / - IN THE ARMY PROJECT COMBINER PANEL.DO NOT ADD LOADS. SOLAR AC DISCONNECT N \ 20-1123 240VAC 27.9 AAC '- -- -- \ \ SHEET NAME 3 4 3., LOCATION: COMBINER PANEL QUANTITY:1 LOCATION: AC DISCONNECT QUANTITY:1 / / WARNING LABELS LOCATION: MAIN DISCONNECT QUANTITY:1 SHEET SIZE ANSI B SHEET NUMBER PV-7 rJ Copyright Elemental Energy 2020. All rights reserved. I