Loading...
Plans Y PROJECT INFORMATION SITE PLAN— KOSMALA i �j ((���I► SOLAR IDFFICE CV} CONTRACTOR: ENERGY SOLUTIONS LLC PO BOX 887 P BEAV0.3718 K OR97004 CITY OFTIGARD �`r� CCB#2.3718 REC■ �/ ccB#zozooz REVIEWED FOR CODE COMPLIANCE OWNER: Approved: [ Vr Hwy MAR 2 2�2ryrt MICHAEL KOSMALA OTC: I l _ VIITYan®�(���+ '��trlinJ 11205 SW FAIRHAVEN ST.TIGARD Permit#: ��© vU� vl��lly`^ 1�1U�SI OR 97223 I lane; 503.956.5574 Address: .c Approved p� BUILDING Suite #: ;,hall be on Soy s . DATA: Date: 3 ;� SINGLE FAMILY RESIDENTIAL B) A APPLICABLE CODES: 43 2017 OREGON STRUCTURAL LIABILITY/3+6I LI TY INSTALLATION SPECIALTY CODE The City of Tigard and its 2017 NEC CODE employees shall not be ROOF SPECS: responsible for discrepancie 0 111 COMPOSITION SHINGLE ROOF which may appear herein. W/2X4 PRE-ENGIN.TRUSSES DOUGLAS FIR#2 @ 24"ON CENTER ROOF AREA GREE'SQ ,,,I,,',' TILT=16 DEGREES AZ= 175 DEGREES ,, �,,�,�,� LOWEST READING=84% SYSTEM INFO: ,,, TE0.MPIp�POl (22)SILFAB SOLAR 380-WATT MONO MODULES P PGC M0 NER PPREI VALIDITY OF PERM T (22)ENPHASE IQ7A MICRO INVERTERS W/ a I - RMIT S STEM SIZE = COMBINER WITH ENVOY :THE I ON CONSTRUCTION MONITORING m SYSTEM ARE=8.36KW PROPERTVURE DOCUMENTS AND OTHER SYSTEM AREA=a9o•sQ <25°r° DATA SHALL NOT PREVENT N THE CODE OFFICIAL FROM ENERGY w�E REQUIRING THE CORRECTION Solutions QF ERRORS. ORSC 105.4 ....- s PROJECT NOTES I. 303.2-PV SYSTEMS AND SUPPORTING STRUCTURE SHALL 6. ...CONTINUED...SECTION IS LARGER THAN 150 FEET MEASURED 10. PER 305.4 ITEM 3-TOTAL SYSTEM WEIGHT SHOULD NOT COMPLY WITH REQUIREMENTS OF OSSC CHAPTER 6 OR THE IN LENGTH OR WIDTH.EXEMPTION I A:WHERE PV ARRAY DOES EXCEED 4.5 PSF.PV MODULES AND RACKING SHALL BE ORSC AS APPLICABLE NOT EXCEED 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF DIRECTLY ATTACHED TO ROOF FRAMING.ATTACHEMENTS 2. 303.3-ALL PV MODULES TO BE UL 1703 LISTED AREA OF THE STRUCTURE,A MINIMUM OF 12"UNOBSTRUCTED SPACING WILL BE 48"ON CENTER MAX,WHEN ATTACHMENT IS 3. 303.5-PV SYSTEM SHALL HAVE A FIRE CLASSIFICATION THAT PATHWAY SHALL BE MAINTAINED ALONG EACH SIDE OF ANY LOCATED WITHIN 3'OF ROOF HIP,EDGE,EAVE,AND RIDGE IS EQUAL TO OR GREATER THAN THE ROOF ASSEMBLY HORIZONTAL RIDGE. SHALL BE 24"ON CNETER MAX REQUIRED BY OSSC SECTION 1501.1 7. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED WOOD I I. MAX MODULE HEIGHT WILL NOT EXCEED 12"OFF ROOF 4. 303.6-ALL COMPONENTS OF THE PV SYSTEM SHALL BE CONSTRUCTION WITH 2X4 TRUSSES AT 24"ON CENTER MAX SURFACE RATED FOR THEIR USE. EXEMPT FROM ALLOWABLE SPAN REQUIREMENTS IN TABLE 12. SECTION 304.7-MECHANICAL EQUIPMENT CLEARANCES OF 30" 5. 303.4-303.8-PV LAYOUT SHALL NOT RESTRICT EGRESS, 305.4.1 MINIMUM ON ROOF. LIGHT,VENTILATION,OR ROOF DRAINAGE 8. 304.9.5-DISCONNECTS,J-BOXES,COMBINER BOXES OR 6. 304.9.1 GERNERAL PATHWAYS REQUIREMENTS EXEMPTION l: GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED PATHWAYS ON STRUCTURE WITH A PV ARRAY AREA OF 1,000 SF OR LESS OR CUTOUTS ATTACHMENTS EVERY 24"ON CENTER INSTALLED ON A ROOF WITH A SLOPE THAT EXCEEDS 2:12 9. ROOF MATERIAL IS COMPOSITION ROOF,IF METAL,FOLLOWS WHEN UNDER 36"FROM ANY HIP,EAVE, Air. arsirf AND WITH AN INTERSECTING ADJACENT ROOF WHERE NO PRECRIPTIVE PATH IN 2010 OREGON SOLAR CODE RIDGE,OR VALLEY.ATTACHMENTS ARE EVERY 48"WHEN OVER 36" ° .�. ,, ' ` . • tiF, , `' t ` .= :•74..46:07:410:. 1 A 1 :iirll' al I riii t a t 1 411111111511 V r k t. LOWEST RE.OIhO ��' _ [ L�� w s^ i ENERGY SOLUTIONS,LLC MICHAEL KOSMALA PO BOX 887 11205 SW FAIRHAVEN ST. N BEAVERCREEK,OR 97004 TIGARD OR 97223 ENERGY 503.680.3718 503.956.5574 W -.gel' ` E Solutions CCB#202002 8.36 KW SOLAR ARRAY-RESIDENTIAL • ENLARGED ROOF PLAN r s ,9T i i i i i i i i i i i i i i i i 1 1 I 1 1. i i i i 3 Iv V i i o i i .__ • --i----- -- -- obi. , . cr -- i , 1 cc VIi i i W M I 1 _ MOUE ENO CLAMP rXe MANUFACTURED TRUSS 1-l - am= .- -i-, 1111M m . _... ,,......_rol: 1 1 1 MOORE CU& ..----- t!do,Il• :ki __,. _-- 4 ...—24"V.M.—.*I 1 1 I PVMOOULE nv. 1 i MODULE FT CLAMP 1 _,-....„....--- 1.-FOLYT i 1 . NANG HAL _,4 id FLASHING I 1 I 1 1 4 ------,---- - r--i- ,_--_ ---'-'—:. r-14-1 1 ' I -'ailigilliairr" 5/164.5!MOM L- 1 - -I I ' f' - MUD 11 14" -Pitt MIN 2.1:211tREMPENSRATION WI C$4811M MI(OR EDON) 1 -t 1 i 1 I ! , 11111 ! , ' ' I i i .., _48N mAx...._—, (D MOUNTING PLAN VIEW IPO3TRAM 0 ___ SCALEr MOUNTING 06A11. ECM F. 1^is 1.4. t 74* —__ _ -- -- .— _ —_-- 5.25:jr. cis\w" - -,,,-;---7-,"---- .oP•"'' OR . -:,,,,,•••""s OA ....; (9) MOWING METHOD MALE 1`1,7.0' - - - — System Information Labels PV Module Ratings Inverter Ratings Photovoltaic AC Disconnect Module Make Silfab Inverter Make Enphase AC Output Current = 31.9 A E NERGY Module Model SIL-380 NT Inverter Model IQ7A-72-2-US Nominal AC Voltage = 240 V Max Power = 380 W Max. Output Power = 349 W Solutions Open Circuit Voltage = 47.95 V Max. DC Voltage = 58 V Max Power Point Voltage = 39.25 V Norminal AC Voltage = 240 V P.O. Box 887 Short Circuit Current = 10.29 A Max. AC Current = 1.45 A Beavercreek, Oregon 97004 Max Power Point Current = 9.69 A GEC Inverter Efficiency = '37.0% Phone: 503-680-3718 Meter Main 1 (/v,j //��� Panel ILIT ` �� r/ O ©O \0 J Q SETRVII $ 'el +! 11 Modulesw! Main )200A �1a J-Box AC Main Solar \ \ OCPD A+A# Micro-inverters ! (at array) Combiner AC A1•' II Branch#1 / t e A Panel Disconnect \ / w/(2)20A / w/ Circuit - Unfused - M11 icrc-invertersModules Breakers // I ^ 40A Branch#2 [ // / / d D c3 6 � G u 270A Bus = BUILDING GROUNDING ELECTRODE PV System meets requirements for Rapid Shutdown as defined in 690.12 EQUIPMENT SCHEDULE REF DESCRIPTION PN NOlnS Notes: 1 SOLAR P✓MODULE SIL-380 NT SILFAB 380W MONOCRYSTALLINE MODULE o Equipment, conductors and conduit 2 AC/DCMICRO-IM/ERTER IQ7A-72-2-US ENPHASE349WMICRON/I:HiHt as listed or equivalent. 3 ARRAY HARDWARE TBD FLUSH MOUNT ROOF RACKING o DC side of the Micro-Inverter is 4 JUNCTION BOX TBD FOR TRANSFIION FROM TRUNK CABLE TONM CABLE(ROME() isolated. A DC CEG is not required. 5 AC COMBINER PANE X-IQ-AM1-240-2 ENPHASE IQ COMBNER+PANEL MID ENVOY, 125A BUS BAR 6 BRANCH CIRCUIT OCPD BRK-20A-2-240 EATON BR220,20A,2-POLE,240V CIRCUIT BREAKER(BACK-FED) ONE-LINE STANDARD R ECTPoCAL DIAGRAM 7 MAIN SOLAR AC DISCONNECT DU222NRB SQUARED,SAFETY SWITCH,60A,240V,2-POLE,UNFUSED PROJECT REF: Mchael Kosrnala 8 MAIN SOLAR OCPD TBD 40A,2-POLE,240V CIRCUIT BREAKER(BACK-FED) SIrEADDRES: 11205 SW Fairhaven St,Tigard, 9 METER MAIN N/A 200A BUS W/200A MAN BREAKER,240V(EXISTING) OR 97223 CONDUIT&CONDUCTOR SCHEDULE SYSTEM SIZE 8.36 kW REF DESCRIP./CONDUCTOR TYPE CONDUCTOR GAUGE NUMBER OF CONDUCTORS CONDUIT TYPE CONDUIT SIZE 2 Branches of 11 Modules/Inverters(Silfab 380/ A ET'M HASEQ-12-20-200 CABLE #12 2(Fr Cable) IN FREE AR Enphase IQ7A) B BARECU #6 r 1 IN FREE AR Sheet 1 of 3 C NM or NMC(Romex) #12/#8 2/1 (x 2) IN FRQAR Date: March 15, 2020 D THWN-2 #8/#8 3/1 BUT 1" NOT TO SCALE PORTLAND/HILLSBORO Elev. High Temp Distance above roof Extreme ENERGY 0.4% 2%Avg. 0.5" 3.5" 12" Min Solutions 62 m 37 °C 32 °C 54°C 49 °C 46 °C -8 °C Correction Temperatures Voltage Drop calculations: P.O.Box 887 .61- °°id=-8°C-25°C=-33°C ATn°t=(37°C +35°C)-25°C=47°C DC voltage drop is insignificant because of micro-inverters mounted at Beavercreek,Oregon 97004 Flush Roof mount PV modules. Phone: 503-680-3718 Module Voltage Calculations Tables for IQ7A internal branch circuit voltage drop not yet available Silfab 380W NT Mono(SIL-380 NT) from Enphase. Calculations on voltage drop per module for 6 Voc=47.95V Vmp=39.25V Voc Temp Coefficient=-0.30%/°C modules worked out to be 0.21%. That number is consistent with = = Coefficient=-0.38%/°C voltage drop for a branch of 6 IQ7X microinverters in portrait lsc 10.29A Imp 9.69A Pmax Temp orientation-given as 0.19%in the Enphase Technical Brief on Cold Voc=47.95V+(47.95V x-0.30%/°C x-33°C)=47.95V+4.74V=52.7V Calculating AC Line Voltage Rise for IQ-Series Micros with Q Cable. Hot Vmp=39.25V+(39.25V x-0.38%/°C x 47°C)=39.25V-7.01V=32.2V (0.19%x 1.45A/1.31 A=0.21%) Branch circuits are to be Center-fed. Enphase IQ7A-72-2-US Worst case branch circuit drop on branch of 11. Max DC Input Voltage: 58V Max Isc: 15A AC conductor run from junction box to AC Combiner is 40 ft(est) DC Operating range: 18V-58V Start Voltage: 30V Micro-inverter output voltage is 240V, 1.45A x 11 = 15.95A AC output voltage:240V AC output current: 1.45A (2 x 40ft x 15.95A x 1.980/kft x 100)/(1000ft/kft x 240V)= 1.05% Max Branch Circuit Size: 11 Max Branch Circuit OCPD: 20A AC conductor run from AC Combiner to Interconnection is 15 ft(est) Conductor Amoacitv. OCPD&Disconnects Micro-inverter output voltage is 240V, 1.45A x 22=31.9A Branch Circuit: (2 x 15ft x 31.9A x 0.7780/kft x 100)/(1000ft/kft x 240V)=0.31% 1.45A x 11 x 125%= 19.9A 0.21%+1.05%+0.31%= 1.57%total worst case voltage drop Conditions of use-2 separated branch circuits in nonmetallic sheathed cable (2 current carrying conductors per)not on the roof: 19.9A+1.0= 19.9A #12 AWG NM(rated for 20A into 60°terminals and required OCPD) 20A,240V,2-Pole Back-Fed Circuit Breaker in AC Combiner Panel AC Combiner Output Circuit: 1.45A x 22 x 125%=39.9A #8 AWG(rated for 50A into 75°terminals and required OCPD) 40A,2-Pole,240V Back-Fed Circuit Breaker in the Main Service Panel 60A,2-Pole,240V, Unfused AC Disconnect at the service entrance Table 1.13:Internal Q Cable VRise (Portrait Cable, Q-12-10-240) IQ 7X 240V P IQ 7X Microinverters per branch ELECTRICAL CALCULATIONS PROJECT REF: Mchael Kosrnsla 1 2 3 4 5 6 7 8 9 10 11 12 SITEADDRESS: 11205 SW Fairhaven St,Tigard, OR 97223 Current(A) 1.3 2.6 3.9 5.3 6.6 7.9 9.2 10.5 11.8 13.1 14.4 15.8 SYSTEM SIZE 8.36 kW 2 Branches of 11 Modules/Inverters(Silfab 380/ VRise(V) 0.02 0.07 0.13 0.22 0.33 0.47 0.62 0.80 1.00 1.22 1.46 1.73 Enphase 07A) Sheet 2 of 3 VRise(%) 0.01 0.03 0.06 0.09 0.14 0.19 0.26 0.33 0.42 0.51 0.61 0.72 Date: March 15, 2020 Notes: • PV System compliant with requirements for Rapid Shutdown per 690.12. ENERGY • Each microinverter is attached to the racking at the back of the corresponding PV module. • Enphase Raw Q Cable(#12 AWG)is used to span from the Enphase Q Solutions Trunk cable of each branch to the penetration through the roof. Once below the roof,conductors are transitioned to Nonmetallic Sheathed Cable(Romex or equivalent). The Raw Q Cable is installed below the array and attached to P.O.Box 887 Beavercreek,Oregon 97004 racking frame members. Phone: 503-680-3718 • Branch circuits penetrate the roof where the transition from Enphase Trunk or Enphase Raw Q Cable to Nonmetallic Sheathed Cable is made. • The AC Combiner Panel&Main Solar AC Disconnect are located on the south side of the residence,adjacent to the Meter Main Panel. • Interconnection via a back-fed circuit breaker in the Main Service Panel. Complies with 705.12. • Nonmetallic Sheathed Cable will be run(per Code)in open space. No deratings for condition of use will be required. • Circuit breakers in the AC Combiner Panel serve as disconnecting means for each branch of microinverters. • The Q Cable will be connected in a"Center-Fed"configuration to minimize AC voltage drop in each branch. • Enphase recommends maintaining a total voltage drop for 2%or less from the array to the point of interconnection,and a less than 1%for the Q Cable. • Conductor run lengths and voltage drop to be confirmed. Conductors will be upsized as required to maintain 2%or less total voltage drop. • Conductor sizing listed is minimum required based on NEC ampacity calculations for CU conductors or voltage drop calculations. • Conduit sizing based on listed conductors and NABCEP recommended maximum fill of 25%. Conduit sizing may need to be recalculated for conductors of a different type. Conduit may be sized to comply with NEC, Annex C. • All electrical work must be made in accordance with the local and applicable National Electrical Code ANSI/NFPA 70. • PV System to be installed and labeled per National Electric Code. Specifically: -690.4(D) -690.31(B) -690.5(C) -690.35(C)and(F) -690.13(B) -690.5(C) -690.17(E) -705.12(D) • Inverters listed to UL-1741 for grid-interactive use and GFDI protection. • All equipment used UL listed. DESIGN/BUILD NOTES PROJECT REF: Mchael Kosmala SITEADDRESS: 11205 SW Fairhaven St,Tigard, OR 97223 SYSTEM SEE 8.36kW 2 Branches of 11 Modules/Inverters(Silfab 380/ EnphaselQ7A) Sheet 3 of 3 Date: March 15, 2020 Classic Composition Mount QMSC /--THIS EDGE TOWARDS N"-Z RACKING COMPONENTS 2.50 ROOF RIDGE 1 NI 1 NOT INCLUDED I. .5l I ' 1 II O I I II © O u 0 O ill 12.00 I 1.50 eZ I © ,Ir 3.00 1 0 ITEM DESCRIPTION QTY. 6.00 NO 1 FLASHING, 12"X 17'X.050",5052,MILL 1 12.00 2 QBLOCK,CLASSIC,A360.1 CAST AL.MILL I 3 HANGER BOLT,PLAIN CENTER,5/16"x 6", 18-8 SS I r 1Li 1 4 WASHER,SEALING, 5/16"ID X 3/4"OD,EPDM BONDED SS I s"11 5 NUT.HEX.5/16-18,UNC-28, 18-8 SS 2 i� `4 6 WASHER.FLAT, 19/64"ID x 7/8"OD x 1/8" EPDM 1 t 1.30 7 WASHER,FENDER,5/16"ID X 1"OD,18-8 SS 1 _ f ' 8 WASHER,SPLIT-LOCK,5/16"ID.18-8 SS 1 4 $.00 Quick Mount PY' TITLE: 1. QMSC: CLASSIC COMPOSITION MOUNT AVAILABLE IN MILL,CLEAR ANODIZED, AND BRONZE ANODIZED FINISHES. UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY; RAD REV DIMENSIONS ARE IN INCHES TOLERANCES. A DATE'. 7 PRORlMRV ANDCONFIOW14t FRACTIONAL NA /23/2013 6 HxrNIORNATI pi 114 o1Awme 61W OWE WOPexu ON ,011 mowPv AN,x npp0CIOH Iry PART Ol AS DO NOT SCALE DRAWING IW OMCE DECIMAL tlg A Wiii,.T MMOUS NM(wemtx eERHHSfq,OIOACR MOAN!w 6150,e,PD THREE PLACE DECIMAL -.125 SCALE-Ia WEIGHT:1.24 SHEET I OF I 5 4 3 2 I Lag pull-out(withdrawal)capacities(Ibs)in typical lumber: Lag Bolt Specifications Specific Gravity 5/16'shaft per 3'thread depth 5716'shaft per 1'thread depth Douglas Fir,Larch .50 796 266 Douglas Fir,South .46 705 235 Engelmann Spruce,Lodgepole Pine(MSR 1650 f&higher) .46 705 235 Hem,Fir .43 636 212 Hem,Fir(North) .46 705 235 Southern Pine .55 921 307 Spruce,Pine,Fir .42 615 205 Spruce.Pine,Fir(E of 2 million psi and higher grades of MSR and MEL) .50 798 266 Sources:American Wood Council,NDS 2005,Table 11.2 A,11.3.2 A Notes: I)Thread must be embedded in a rafter or other structural roof member. 2)See NDS Table 11.5.1 C for required edge distances. Quick Mount PV"' RESPECT THE ROOF BI 7.2.3-7 Apr-2014,Rev 6 .Os% L • ) i lfaID---..„1, S L — 380 ., SOLAR .. .JUST =PVtL TIER 1 0'. ARRA PHoou -IN- __ BANKABLE / ONV.GLa(11 ry a TIME n�,,, $$$ HIGH 72 CellINDUSTRY LEADING WARRANTY All our products include an industry leading 25-year product workmanship and 30-year performance warranty. '� —-- _.._! Monocr stalline -_ _ Y 35+YEARS OF SOLAR INNOVATION PV Module Leveraging over 35+years of worldwide _� experience in the solar industry,Silfab ` is dedicated to superior manufacturing , ,__„_ processes and innovations such as Bifacial and Back Contact technologies, . -- to ensure our partners have the latest in solar innovation. -- NORTH AMERICAN QUALITY • C E fJ� l 0l ® I EC Silfab is the largest and most automated M,J..* 1.9 i.:.v.� -• solar manufacturer in North America. --- � ® . Utilizing premium quality materials and Flt �Fraunhofelat r _strict quality control management to deliver the highest efficiency,premium quality PV • . • modules 100%made in North America. CHUB B "Chubb provides error and o n,ssinn insurance to 911ab Solar Inc. BAA/ARRA COMPLIANT DOMESTIC PRODUCTION Silfab panels are designed and manufactured to meet Silfab Solar manufactures our PV modules in two automated Buy American Act Compliance.The US State Department, locations within North America.Our 300+North American US Military and FAA have all utilized Silfab panels in their team is ready to help our partners win the hearts and minds solar installations. of customers,providing customer service and product delivery that is direct,efficient and local. LIGHT AND DURABLE Engineered to accommodate low load bearing structures up SLEEK DESIGN to 5400Pa.The light-weight frame is exclusively designed for Sleek design in silver frame with white backsheet. wide-ranging racking compatibility and durability. PID RESISTANT LOWEST DEFECT RATE PID Resistant due to advanced cell technology and material Total automation ensures strict quality controls during the selection.In accordance to IEC 62804-1 entire manufacturing process at our ISO certified facilities. 48.18 ppm as per December 2018. Printed on recycled paper. CS h Electrical S 1 ecifications SIL-380 NT mono PERC Test Conditions STC NOCT _ Module Power(Pmax) Wp 380 287.6 Maximum power voltage(Vpmax) V 39.25 35.32 Maximum power current(Ipmax) A 9.69 8.14 Open circuit voltage(Voc) V 47.95 44.36 Short circuit current(Isc) A 10.29 8.43 Module efficiency % 19.2 18.2% Maximum system voltage(VDC) V 1000 Series fuse rating A 20 Power Tolerance Wp -0/+10 Measurement conditions:STC 1000 W/m2•AM 1-5•Temperature 25°C•NOCT 800%Wm'•AM 1.5•Measurement uncertainty 5 3% •Sun simulator calibration reference modules from Fraunhofer Institute.Electrical characteristics may vary by±5%and power by-0/+10W. Temperature Ratings SIL-380 NT mono PERC Temperature Coefficient 1st %l°C 0.03 Temperature Coefficient Voc %/°C -0.30 Temperature Coefficient Pmax %/°C -0.38 NOCT(±2°C) °C 45 Operating temperature °C 40/+85 Mechanical Prorerties and ComIonents SIL-380 NT mono PERC Module weight(t 1 kg) kg 23.5 Dimensions(HxLxD;t1mm) mm 1992x994x38 _ Maximum surface load(wind/snow)* N/m' 2400 Pa rear load/5400 Pa front load Hail impact resistance 0 25 mm at 83 km/h Cells 72-Si mono PERC-5 busbar-158.75 x 158.75 mm Glass 3.2 mm high transmittance,tempered,DSM anti-reflective coating Backsheet High durability,superior hydrolysis resistance,multi-layer dielectric film Frame Anodized Al Bypass diodes 3 diodes,20SQ040(45V,20A) Cables and connectors 1200 mm 13 5.7 mm(4 mml,MC4 compatible(refer to installation manual) unction Box UL 3730 Certified,IP67 rated Warranties SIL-380 NT mono PERC Module product workmanship warranty 25 years** 30 years Linear power performance guarantee 97%end 1" ear , a 90%end 12"' ear a 82%end 25nh ear z 80%end 30t ear Certifications SIL-380 NT mono PERC ULC ORD C1703,UL 1703,IEC 61215,IEC 61730-1 and IEC 61730-2 Certified.FSEC and Product CEC listed.IEC 62716 Ammonia Corrosion,IEC 61701:201,Salt Mist Corrosion Certified R a UL Fire Rating:Type 1 (1500V)or Type 2(1000V)or Type 1 on request o Factory ISO 9001:2015 8 13 EEE Modules Per Pallet:25 ' Eff vs.Irr Performance SIL-380 NT o an Pallets Per Truck:30 21 EH Modules Per Truck:750 20 __ - - 10°C __ •c I • o *Please refer to the Safety and Installation 19 - __- -25°C Grounding 'N Manual for mounting specifications. Z' 'f{,- + --- 55°C ondn(ge(x8) W. - Hub `_ 0 51 2 **12 year extendable to 25 years subject to ' 15 1V1' -- - Max Eff@ 25°C[700W/m'] 19.33% !7 tMounting) u\ E registration and conditions outlined under 17�i c "Warranty'at www.silfabsolar.com. g' 16 r» .e 70°C ._i a A Warning:Read the installation and User c 14 YF _ Eff@ 25°C,1000W/m' 19.21% s Manual before handling,installing and r Rel.Eff@ 25°C,600W/m' +0.60% `( .J , operating modules. 13 Rel.Eff@ 25°C,400W/m' +0.07% m Third-party generated pan files from Fraun- 12-Rel.Eff@ 25°C,200W/m' -2.0% hofer-Institute for Solar Energy Systems ISE i i i 1 1 i I1 '_, are available for download at o ago ago 600 800 1000 1200 www.silfabsolar.com/downloads -. -.... _.. Irradiance(W/m') Rene Vine 1c g J 5 Gat(.2) B I�':�;;:; Silfab Solar Inc. Grounding Hole :' 240 Courtneypark Drive East ° "',- Mississauga ON L5T 2Y3 Canada ":ro.,,,,, >..nyr.Lra Sit fa b""• Tel+1 905-255-2501 I Fax+1 905-696-0267 _ 501Ag info@silfabsolar.com I www.silfabsolar.com gg] _ ry EOM® Silfab Solar Inc. r301TTOPPERFORMER sa s 800 Cornwall Ave I }pyd °i.°I Bellingham WA 98225 USA l PY MODULE a Tel+1 360-569-4733 RELIABILITY SCORECARD a Data Sheel Enphase Microinverters Region AMERICAS Enphase The high-powered smart grid-ready Enphase IQ 7A Micro' dramatically simplifies the IQ 7A Microinverter installation process while achieving the highest system efficiency for systems with 60-cell and 72-cell modules. Part of the Enphase IQ System,the IQ 7A Micro integrates with the Enphase IQ Envoy', Enphase IQ Battery',and the Enphase Enlighten" monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) - 1 Efficient and Reliable mtm • Optimized for high powered 60-cell and 72-cell modules • Highest CEC efficiency of 97% • More than a million hours of testing "R1137ASE IOTA 1== • Class II double-insulated enclosure • • UL listed t — , ®mom � do Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride through requirements • Envoy and Internet connection required • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) 0 CERTIFIED E N P H A S E To learn more about Enphase offerings,visit enphase.com e Enphase IQ 7A Microinverter INPUT(DC) IQ7A-72-2-US Commonly used module pairings' 295 W-460 W+ Module compatibility 60-cell,66-cell,and 72-cell PV modules Maximum input DC voltage 58 V Power point tracking voltage range' 18 V-58 V Min/Max start voltage 30 V/58 V Max DC short circuit current(module Isc)' 15 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT(AC) @ 240 VAC @ 208 VAC Peak output power 366 VA 295 VA Maximum continuous output power 349 VA 290 VA Nominal(L-L)voltage/range' 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 1.45 A(240 VAC) 1.39 A(208 VAC) Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuits 11 (240 VAC) 11 (208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor(adjustable) 0.85 leading... 0,85 lagging EFFICIENCY @240 VAC @208 VAC CEC weighted efficiency 97.0% 96.5% MECHANICAL Ambient temperature range -40°C to+60°C Relative humidity range 4%to 100%(condensing) Connector type:DC(IQ7A 72-2-US) MC4 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enohase&4m/en-us/supoort/module-comoatibility. 2.CEC peak power tracking voltage range is 38 V to 43 V. 3.Maximum continuous input DC current is 10.2A. 4.Voltage range can be extended beyond nominal if required by the utility. 5.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com ©2019 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery,Enphase Enlighten,Enphase IQ n E N P H A S E Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change 2019-11-07 �� tyata Sl eel Enphase Networking Enphase The Enphase IQ Combiner+'" with Enphase IQ Envoy' consolidates interconnection IQ Combiner+ equipment into a single enclosure and (X-IQ-AM1-240-2) streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, — I Ethernet,or cellular • Provides production metering and optional consumption monitoring ar t • Supports installation of the ‘' _ Enphase Q Aggregator'" 111 i Simple _ t , If` f' • Eaton BR series panelboard interior • fit, •mrr�iva ��t� • Up to four 2-pole branch circuits for 240 VAC ; plug-in breakers(not included) • BOA total PV or storage branch circuits 1 Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year warranty • UL listed LISTED ENPHASE To learn more about Enphase offerings,visit enphase.com Enphase IQ Combiner+ MODEL NUMBER IQ Combiner+X-IQ-AM1-240-2 IQ Combiner+with Enphase IQ Envoy'for integrated revenue grade PV production metering (ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5%). ACCESSORIES(order separately) ---------- Enphase Mobile Connect' CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G LTE CAT-M1/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring CT CT-200-SPLIT Split core current transformers enable whole home consumption metering*(+/-2.5%). Circuit Breakers BRK-15A-2-240 Breaker,2 pole,15A,Eaton BR215 BRK-20A-2-240 Breaker,2 pole,20A,Eaton BR220 ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 240 VAC,60 HZ Eaton BR series busbar rating 125 A Max.continuous current rating(output to grid) 65 A Max.fuse/circuit rating(output) 90 A Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DO)breakers only(not included) Max.continuous current rating(input from PV) 64 A Max.total branch circuit breaker rating(input) 80 A(any combination) Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy MECHANICAL DATA Dimensions(WxHxD) 49.3 x 46.5 x 16.0 cm(19.4"x 18.3'x 6.3") Weight 7.5 kg(16.5 Ibs) Ambient temperature range -40°C to+46°C(-40°to 115°F) Cooling Natural convection,plus heat shield Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 3 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters(6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet 802.3,CatSE(or Cat 6)UTP Ethernet cable-not included Cellular Optional,CELLMODEM-01 (3G)or CELLMODEM-03(4G)(not included) COMPLIANCE Compliance,Combiner UI.1741 CAN/CSA C22.2 No.107.1 47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Compliance,IQ Envoy UL 916 CAN/CSA C22.2 No.61010-1 *Consumption monitoring is required for Enphase Storage Systems. To learn more about Enphase offerings,visit enphase.com ©2018 Enphase Energy.All rights reserved.All trademarks or brands in this document are registered by their respective owner. E N P H A S E 2018-05-02