Report I=PS ZOIS—caa023 DELT,� «7a 7z�a 14795 S.W. 72'° Avenue PORTLAND, OR 97224 PHONE 503-620-4020 FIRE, INC. CCB#64;674 1058 RECEIVED FEB 17 2015 CITY OFTIGARD BUILDING DIVISION SERVPRO Tigard, OR DATA SUBMITTAL FOR FIRE PROTECTION SYSTEM January 15, 2015 DELTA FIRE, INC. WORK ORDER # 25167 FIRE PROTECTION CONTRACTORS SERVPRO January 15,2015 Page 2 of 2 TABLE OF CONTENTS Pipe & Fittings Steel Pipe Ductile Iron Fittings Sprinkler Heads Reliable Model F IFR-56 'A" 155 Degree Chrome Pendent Reliable Model FlfR-56 %" 200 Degree Chrome Pendent FIRE PROTECTION CONTRACTORS 14795 S.W. 72nd Avenue • o, 'xA PORTLAND, OR 97224 PHONE 503-620-4020 FAX 503-620-1058 CCB#64174 Pipe Fittings FIRE PROTECTION CONTRACTORS a III a SINSIU s nnr. amnr a a- . �. _- - >Pipe and Supply Corp. Pipe Specification A135 Specification A135 NPS 1/4-- 30", Schedules 10, 40 and XL THD, Lightwall Scope Covers two grades of electric resistance welded steel pipe. Grade A is adapted for flanging and bending and is suitable for welding. Purpose for which pipe is intended should be stated on order. Kinds of Steel Permitted Open-hearth Basic-oxygen For Pipe Material Electric-furnace Permissible Variations The minimum wall thickness at any point shall not be more than 12.5%under the nominal wall thickness specified. in Wall Thickness Threadable,Lightwall(XL)must meet manufacturers minimums. Chemical C max% Mn max% P max% S max% Requirements Seamless or ERW Grade A 0.25 0.95 0.05 0.06 Grade B 0.30 1.20 0.05 0.06 Tensile Grade A Grade B Requirements Tensile Strength,min.,psi 48,000 60,000 Yield Strength,min.,psi 30,000 35,000 NDE& Hydrostatic inspection test pressures for plain end and threaded are specified. Hydrostatic pressure shall be maintained Hydrostatic for not less than 5 seconds for all sizes of electric resistance weld pipe. Non-destructive electric test should be in accordance Testing with practices E213,method E227 or practice E213. Permissible Variations Plus or Minus 10%schedule 10 in Weights per Foot Plus 10%minus 3 1/2%schedule 40 Permissible Variations Plus or minus 1% in Outside Diameter Mechanical Tests Tensile Test--Transverse returned on pipe NPS 8 and larger. Specified Flattening test--Three steps required with weld located 0°or 90°from the line of direction of force required. Number of Flattening and tensile on one length of pipe from each lot of 400 lengths or less of a style. Tests Required . Lengths Pipe shall be furnished in 38'with a minimum of 20 ft. Pipe furnished to schedule 10 shall be in a specified length between 16 and 22 tt. Required Markings Rolled,Stamped or Stenciled(Mfgrs.Option) on Each Length Name or brand of manufacturer. (On Tags attached to Kind of pipe,that is,electric-resistance welded A,electric welded B,same schedule wall thickness,schedule 10 or 40,NL each Bundle in case ASTM A135 of Bundled Pipe) Length of pipe. General End finish may be plain end beveled or plain end square cut. Information (119, 4..wtir; SO' ELBOW Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fiftings are UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to AS1v1E B16.3 Threads are NPT per ANSI/ASME B1.20.1. •NOTICE:Ductile iron ti011egs ham higher fernfe 5trength than that of steel pipe,Therefore,twer tightening oon cause doinoge to pipe*we**whi.aw may toase leckoge.Ode iron hefec s should be tightened three iTJMS beyond hoed 6*.but no mote than four tutns, eC)13. LEIS APPROVO LA4VV4Ptmea NO* SO ELBOW wo..414,te UN*Hit044PRIS0A, Nominal size Max_Working Dimensions Pressurt, A Vit E96 1 SRI ISO 1.50 D.62 Ti 34.52 0 38,10 0 18 500 135 1/5 090 34.5) 44 45 44 46 B : SOO 1.94 1.94 1.20 4.9 3490 40114 0 54 2 500 2.25 225 4 1.05 50 ' A 'M. yourrIxI Anwf 45° ELBOW %Z, ANVIL t Ductile Iron MATERIAL SPECIFICATIONS Ductile hart threaded fittings are Ul&ULC Listed& FM Approved for 500 psi service. Ductile iron per ASTM A536 Class65-45-12. Dimensions conform to ASME B 16.3 Threads are NPT per ANSI/ASME B 1.20.1. NOTICE:Nettie iron freineR have higher heregle Prength thetn that of steel pipe,Tleseelore,over tightening or to pipe winds "cause leakage.Duals iron fittings einneed be tightened three earns beyond h: el tight but no awe than lour tixnt e es ammo Inti45' ELBOW r< WNW*We 600 Y0A IPAW, IXNiIT Nominal Sire Mow.Waning 0&rtiensians gyAppear.. Ir MIKOA A $ Ttt,iWd! 500 1.12 1.12 0.46 2 31 :€N 2244 )21 • 1'k 5003 1.29 129 0.73 weir 32 3450 32 7t X'33 €333 A ._ ,,. 1't 1.43 1.13 092 fi • t1 Rr 133.a 3i32 0 32 2 500 1.68 1.68 1,50 34 0 A 42 32 42 37 264 A-VN+crkig Rre6e4TD ore lar refew000nly told homed err Sat*,40 pipc Far thebsexe reel FM prep ere nein:m. r pipe Ithedvic preen visit onelin treat or carded}pow incel Anvil STRAIGHT TEE Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore 111& UtC listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Ckiss 65-45-12. Dimensions conform to ASME B16.3 Threads are NPT per AN$I/ASME B1.20.1-- -- ---- -- - ---------- NOTICE:Dud&irte kings ho kicker tensile strength than than sser4 pips.ihereions,over Agidening ow=pm doisnov to p.pa*Tooth slush may cause leakage.beak iron teems should he tightened titres eons beyond hard AO,but no more+or .6Jr Amu. t013 UREA APPROVED PoLOPDOPORmi DAT0 aol adberax. STRAIGHTTEE ft0E wr,antoze.a*ovwea§,Arg wanucl al,Mae%a**Nvv,ew tWY, Max.%firing Dimensions Honied Size ,L riessurtA A Wh..Each At-A0107,-- -7/0V87 f ieii- 500 1.30 1.50 0,85 B 26 3450 a 10 560 1.75 1J5 1.22 32 3450 44 45 44,500 1. i 0 55 1.94 1.55 • 40 340 4P,2 A A—4-1 2 500 2.25 2.25 2.15 57/5 r -Waking Presses Passe Pro hr nekesseetertty and based an Sch.40 pipe Fur Ps keg UtAttC, and Pre narestre ratings rases six seheiste please vi$i <19Telfiriii.03431 Kit woad veer kat Asset itoreteroom.s. BUSHINGS "" " A !'!!. = Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL&ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45.12. Dimensions conform to ASME 816.14 Threads are NPT per ANSI/ASME B1 .20.1. NOTICE:Ruchle won 4+mrigs h mvo Nose twssita erength tfvan thud of sfael pipe.Tiwelate,o»+er t afeening eav*MO&mega to pipe Creech which may cease leakage.Ductile iron beligs should 6e tightened three hear be hood light,but no ova thaet 6o dons, ere fit► btu apPoveo use:us 41 eanw.na tffiftft d LT'ea« Nominal has Max.larkkin ° Oimerslans Approx. eressorea A 8 [ 544. 1Yt Nth *., C,.: t 7* ' k,f 1, - C m' 1 x 500 (175 0,25 1.42 an t - € $ 25 x 5 345E : €5 - x 6 . ,,,.a; 1 • 1 x 0 0.75 25 m 1,42 Ouisido 0.17 25 r 70 34 iFa S 4.35 3E:1 t l t o i WO OM0,28 '' 1.76 Ouhrde 11.28 Inside Head • 32 P 5 34 . 7 7,PI 44.70- 0 4 1 A x I S00 0,13 0,31 2.00 04414 0.15 x7z 3450 71. R 7.1114 5a3.8 E23 11411% 5OO 0.83 0.31 2.00 Ott.* 0.30 !, 1 - f : ,32 3,lid P A5 I534 54 E 0)4 } .6. B 2 x 1 500 0,88 0M 1.95 0.67 A v,r$a d5t7 Y35 iE.4dd 4V3 3 r 2 x 114 SOO 0.88 0.34 2.48 0.13 02 E4 22,,35 8.636 425t' 4.33 Outside Head 2 x I* 500 018 034 2.48 - 0.61 r to € !---: 1235 E.636 83 f9 J 28 ♦-Working Pressure Raines ore lar reference nrie and based Ors 44 pipe For law UtAIC, and pM preltSin.ratirras ranee pqm scheduda,please visa one eariente Of ce=W I year loyal Anvil Peprenertener P CA { +wwurwrsF�l� FdfiV ) Ductile Iron MATERIAL SPECIFICATIONS ^'1" Ductile iron threaded fittings are LJL& LAC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12, Dimensions conform to ASME B 16.14 Threads ore NPT per ANSI/ASME B1.20.1. NOTICE-Ductile krah 6n+rleS/100,41 hirer*Ante strelaniti the that of steel pipe,Theeeiare,aver tigietenieg cart came&imago-to pipe broach which may came leakage.Ductile iron kliegs should be th hIa116d three lures beyamt Rand tight,but rro recce than lour heck 1ffi1t3 APPRGYED riuharre laentifte4, CAP tar -aexMwv *mm Max Working [ Dimensions Approx. Oatnimcd Size pPressuno. A Wtt..Lath �`w41 [y4�{ IDR%?6 j Iit11R", iW�ye.y€.YOB 500 1.16 012 ` -z a`.0 0:33 ''- rI'.. A 500 1.28 0.43 1 h SOO 1.33 0.60 3450 0.2 fi SOD 1.45 0.91 A—Working A+esssnsr&encia are kit'renannne nebtand Wuxi Cm So,40 pipe,Far he lateie MAX, and FM preserve renrsgs*trues rope schedule.pose visit Simi can Of Carded your local Arrr# Eir,,, ANvic COUPLING ... .....,...... Ductile Iron .• MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC Listed & FM Approved for 500 psi service. Ductile iron per ASTM A.536 Class 65-45-12. Dimensions conform to ASME B16.14 Threads are NPT per ANSI/ASME 81.20.1. NOTICE Ductile iron fittings hone fininat ensile erertget than that of ittel pipe Threiceo,ow tighteeiieg eon ow*domege to pipe itroadk whkh may COW.ieakoge.Ductile;foe fie hould be etillteneci three NMI buyooti hand tight but ro mote thoo kyr!vow teams APPIttIVO) Ps*uoivi,sowav*INkuph*A tawhocra, COUPLINGmg ax motwo NW Art.06,4 CM Qe 00.04/ail AI'Ve%P$.ittOnterArot Max.Wanting [ RiflIVISi011$ Apprzl, Nominal Size Prossinei i 4 WI.Eqd1 ,. C....4. I 500 1.67 0.40 25 3450 I 4Z4,7 a 4' IN. 512,VE-, ;;Nor i , 1 1% 500 1.93 0.57 M 345e 4?..02 a26 1W 500 2.15 0.75 . 40 3490 544, 0 34 2 , t 500 2.53 1.15, "sil f 34,56 6,418 , ., A-1A1644tiga Reeve feetege ere 6 relwencv griy and bond on$6,40 pee for the k* LA/ULC, and FM.Ptig44411"Xir91‘'ar445 PceICIWIVIR,0140{0 VESII ISOIAIVIII,Cart or‹ntertzt yo.e Imo!heel Repreterettere CROSS A = ( petvj Ductile Iron MATERIAL SPECIFICATIONS "µ Ductile iron threaded fittings are UL&ULC Listed & FM Approved For 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. ' d ',' Dimensions conform to ASME 816.3 Threads are NPT per ANSI/ASNtE 81.20.1, - W-- NOTICE::Ductile iron fittings have higher issisile*tenth*on kit 01 steal pipe.Therefore..0Vef eriering col tom damage air pipe lied mvy muse Ignitor.Ductile iron kings should be tightened three terns heyoott hand tigist,but no MTV diet tour wins,. rnitiorgargirrioNnirnand CROSSwsaur reow.umaetl men w tdox.gtatrarsg ttimei i nc Apprmz. Narltsaal Site Pre€wren A ` A Wt.Each . nit . i._ 1 500 1,50 1.50 0.18 25 3433 36.70 13 394• w 8a B 1%; 500 1.75 1.75 1,5t9 12 3453 4445 4445 as T r 1 500 1,P4 1.94 I, A : ,....igaR. tp 345d 4922,E 492 2 S00 2,25 2.25 2.95 yyy W _ 53 345 51,t 5173 i 34 . IS 11 500 1758 L67 1 A 1'h x 1 500 1.65 1.30 1.48 40 r 25 1453 41.91 45 42 331 2 x 1 500 1.73 2.0p2ry 2.10 v 15 3450 43.94 s a 015 A—Working Prowire cater odeostos only and bosndon SDK 40gpeFtr the Wed Lk/111C, ardFM prossiro uotings term Opt scbodoievssits�aiirad.weear owed your local Anvil REDUCING 90° ELBOW 7JA6 > Ductile Iron MATERIAL SPECIFICATIONS Ductile iron !brooded fittings ore UL& UtC Listed FM Approved for 500 psi service. Ductile iron per ASTM A536 Class 65-45-12. . "" Dimensions conform to ASME 916.3 Threads are NPT per ANSI/ASME B1.20.1. NOTICE Ductile iron filings hove lisker DADDE PrentEkt dmn that of steel pipe.Theroloro.ogee tightening eon covet elegroge tg pipe giviKach.Wilieit may coxes leekige Duce iron fittiega should be lightened three isms beyond hated tight bur no ream ihon foto ho ns> acre APPROVED REDUCING BO° ELBOW r ` a4 1ANx.W rking , 0itnensinws Approx. 0anunat Size rieESapta A B Wt,Each dx m F5t 1t = t'�i l '. . I I lit I c 500 1.26 1.36 0.44 32A, 04:54 0 20 1 8 2 560 1.37 1,45 0,52 r r- .-.,,. 1. x 500I _ 1434 «• 15.3 . 064 r a':l • .:r i5 3455 34 IS MS ,5,.age 114x16 500 1,45 1.62 012 A :21.4416- 37x20 3450 3603 4124 01 111 x 1 500 1.58 1.67 0.75 W z 25 344550 45133 42.41 i.34 1lix1 1 500 1.65 1.011 0,92_ 40505 3450 4301 - 4532 2.J 1%M 1 500 1.82 1.89 1.08 40 c 32 3450 45.22 4 15 0 40 2 x1i. 500 1.49 1.88 1.08 50x15 3450 2234 4111 945' 2 x 503 1.60 1.97 1.24 5 R20 3450 4l2m 5013 0SD 2 x 1 500 1,73 2.02 1.40 551 2450 43.24 5 t.31a 4.64 2 x 1 grit _ 1.90 2,10 _ 1.52 53432 3453 43.26 53.34 01 2 x 154 500 2.02 2.16 1.65 ,.0x 40 3453 A are 54,56 2li Al.-WeNtitiog Prosksrat Retkgs are krr and hewed en SA.40 pig,.For tea Ideal 4."J14, end Frh petniere mono."Asters Ova vhodule,pitote volt 4:m4A a nr°r sorarAer rot bed,nnl DepremntaDos. REDUCING COUPLING ':VrjANV11:, <CC/FWNT. -EFF Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& UtC Listed & FM Approved for 500 psi service. i'44444' Ductile iron per ASTM A536 Class 65-45-12. Dimensions conform to ASME 816.3 Threads are NET per ANSI/ASME B1.20.1, NOTICE:Durivie Iron klioss krit hightir kool****Eitti th +of of stocd PiPe.Thc-'40.0o,0,,oe 40,4*damage to pipothreo(hvoh1/41 may rouse leakor.Dixiftie iron fit siload bet lightitiood three woo boyood hood tight,two no fr**4*on jr hem. Os 420' MEI APPROMEO Liirroorctioo DOW&A0,44 REDUCINGCOUPLING .".0***7,45,3A,Kvio wortet ocet,ar aVfEtaaM mme iii.044:401,11rAt Werkirl Approx, Menial!!Size Num, A Wt.Earl -4 141011,-- x 500 1.69 A 25,r 160 4? 1 Kg 500 1,69 r 3450 12 72 11 24 —WOrAttrc Pe Ratings are for itArrerre only aoti baud co Sirk 40 pipe.Far**blest MAC. • ord FM promo*roto Ova orrilinttroo or=too your kcal okov4 Reponcoloive. . REDUCING TEE gap,• 12 ( ' :))) Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL& ULC Listed& C FM Approved for 500 psi service. I_ 1 Ductile iron per ASTM A536Class 654512. 1) 1 Dimensions conform to ASME B16.3 I-.-A ; B_..l Threads ore NPT per A1S1/ASME B1.20.1, REDUCING TEE NOTICE:Ductile iron fittings have higher tunsde stoma*than thief of cteti pipe.Therefore.OKI Vetoing con pewee Aga to ppe throe*welch Math Dimensions Approx. may case teckage.Ductile WO timings be tightened wee toms Amnia l Site Wort ng WI.Each beyond hxuul t;r st,but no more thole lour tome Pressures A B C ,- , r y l . t(S)4 ■ : ma i O a nrana uo I 4xl . 500 1.50 1,36 I Po uwookm..11 "LaraldlOnr. 7 7 5 3 25 3450 70 *AM meweinalli",k+aRr*Av 5>s#A eaW*emn.x 1141x1 500 1.50 1.45 1.50 0,73 5 j4 « REDUCING TEE ixioi 5A0 126 1.26 y 1,36 031 44 5715 ,a" 2 x 1 x14 ` .31 4 0.776 Max. Oiinensimms rcx,. x Li 4 3450 "^€fir' 34.50 35 4 oi4 Nominal Sin WaEirg I W.Each 1 x x h 1.67 1.6 1.58 0. Pressure*, A B C 4 3° 3450 42 41 474; 4P3 6- r x1rx11�> I: 1:'t ' 165 116iil u, =A x` s2 a 3433 451 4577 4141 .. 3 113 x 1%4 3 S , S x�'4 4' IA x 1 x lei 1.34 1.26 1.53 0,82 c ( '' • r25x'S 345€ 7404 $030 031 45x11ix1 ,fit., «65 La Lao 1.30 as 444 3 0 tp 329253 « .3500 3' 334 4162 0,901 his 1 x i 73 3515 1182 82 1. 1. 1.c `z 8 1%x l x 1 590 1,58 1.50 1.67 100 403 40 932 3450 434 4343 4775 0.51 7757 75 7431 3' a3273 47 12 ?.4' IAx14fx2 500 216 216 ` 2,02 Loa114 x l e l% 504 1.75 1,67 1,75 1. 40 x 4a'03 4950 5445 347 5I.30 0,29 975777 794 ..... 4- .. V li 4t45.. 244 • 2x1x2 500 2.25 2.02 2.25 ' 2.15 %x14lh 1,80 182 1.42 i 5tt x. 3453 57 1 7,5 $q 432 e 5x4i, 4 4:75 4`77` 49 2x1%x 500 225 ,'1 .25 2.30 r x1§4x'I �. 34 1. t%32#30 3450 577 3344 5715 1,04 L 5 4 4. 32 ' x1Ysx§4 500 1,49 1.41 1.8 1.50 37x42x1; 16x1t4x11 5 1.4 .4� 62 92 q a15 4' 7" 01 4,77 . 4 32x32C712 y4 3t7? _ «4 4l7; 51 i4ax59 $ .6U 1 '2 10 i,62 1 xh4x1 504 1.58 1.58 1.67 1d.95 a40s 3 O,r40 4t` 4 . , y ,1. I a "x225 MO 13 4373 4247 R 2x ilizi S 1,7 165 '2,02 - ,64 x x 1 x Ili 1.1 188 182 1,45 x 5 3 , 4244 I;U2 - $1 l 74 32x3d 240 34:2.. ... 47115 4'75. 4721. 0 _., §4x 11/4 , 50) _._1.90 182 2.1 1.30.._.. l4V x 114 x 2 5002.10 2.10 1.90 1J5 gg0 r 90x 32 ' ,i453' d 4m r",7 5334 b.92 i421430_ 74 , 37124 .., 534.2 _ Z3 +?s4 22x144x1#/ 500 202 1.94 216 2.00 14 x 1 x 15 509 1.41 1.34 - 1.66 895 Yid 40 r 3450 57531 42,29 5433 091 41 r75a15 44' 33 3 14Q4 42171 743 2x19x2 500 225 2.16 225 2,35 1%x I x14 500 1,52 137 1.75 1-14 c k @x5 3450 5775 sa, 5,r t55 3- 7 x7 9 34e - F4 44-0 . 1.811 1 7 2 x x r 508 1.49 1.49 1,1 1.60 x x I65 "^ s � a � e , 4 a , x `_ ,, 3� 45x __ x2 xii tr 1. 1.60 11a.,77 1.68 I*x 1 x 500 1.82 4,71. 1.95 _ 1.45 x xis 500 73 1.7 2, 1,85 40x2 a3? «4a0 4�:�} 4'td 4i 73 ll§k 1 x1xl r 500 ' 1.94 1..8 x x 40225a43� 4423 , 45.'2 4175T 066 2x x154 1.90 1.90 2.10 04 l`Wx1Y 414 50C1 1.41 1.34 1.66 1.05 AA-pt.?? 3450. 4445 47.4 4444 4,43 ' V 4V 7 11 _ . 2459 , 35 11 34.54_ _ 42 13._4, ..0.40. 2 x 2 x 144 500 2.02 .02 2.16 2.18 1°�4x1Yx44 500 1.52 1.45 1.75 1.15 503 90X45-3 3453 4445 4242 4441 032 40 x22e 20 3450 le 31 33 #4.45 Oa .. 2 x 2x 214 500 2.60 210 2.37 3.61 Mx 116x1 500 1.65 1,58 1.80 1,25 SO4 Mc55 3434 ._ a4: 4242 _ 44,45 s 33325 22450 4 71 43393 437" 057 25x2x 500 1.74 1.60 232 2.28 1" i 1A x 2 500 2.16 2.10 1-02 190 5A 51420 2357 i 44 45 42 42 1 44 45 40x 5e50 3450 4f4 53574 51r0 G 573A.-VA:eking ftrensure Ratings ore hree rauea+lyoedtesodc kh,40 pbpa.kad+e l it x Rix ha SOO 1.41 1.41 1.16 1,15 hetet t. `LxC. 4N4 r, nfp r schedule,t elseoimitnil or 4js:t 4PJ s 75 ,44F3 35.,s7. J?3° .,.. ?4 45. ...... a eamtve aw kcal kffeve. EL 14795 S.W. 72nd Avenue PORTLAND, OR 97224 PHONE 503-620-4020 FIRE, I FAX 503-620-1058 U CCS# 64174 S • rinkler ea s FIRE PROTECTION CONTRACTORS Bulletin 014 Rev. F I" . ill Model Fl FR56 Series Quick Response ,. Reliable° Standard Spray 5 • Model F1FR56 Sprinkler Types Standard Upright ' w, Standard Pendent Conventional l� . µ Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types 1 Standard Pendent/F1/F2/FP Upright Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Pendent Illi at Listing & Approvals ,, ®" 1, Underwriters Laboratories Inc. and Certified for Canada(cULus). s - 2. Factory Mutual Approvals (FM) Vertical Sidewall Conventional 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH • UL Listing Category .a Sprinklers,Automatic&Open (VNIV) Quick Response Sprinkler ▪ Product Description Reliable Models F1FR56 Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- Horizontal Sidewall Recessed dard sprinkler with the attractive low profile of a decorative Pendent/F1/F2 sprinkler. The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin- f% klers have demonstrated response times in laboratory tests . which are five to ten times faster than standard response ' or' sprinklers. This quick response enables the Model F1FR56 Series sprinklers to applywater to a fire much faster than '�'° " -fn' standard sprinklers of the same temperature rating. z`° The glass bulb consists of an accurately controlled amount Recessed Recessed of special fluid hermetically sealed inside a precisely manu- Horizontal Sidewall Pendent/FP factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Application At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are used in fixed fire protec be seen as a small bubble. As heat is applied, the liquid tion systems: Wet, Dry, Deluge or Preaction. Care must be expands,forcing the bubble smaller and smaller as the liq exercised that the orifice size, temperature rating, deflec- uid pressure increases. Continued heating forces the liquid tor style and sprinkler type are in accordance with the lat to push out against the bulb, causing the glass to shatter, est published standards of the National Fire Protection As- opening the waterway and allowing the deflector to distrib sociation or the approving Authority Having Jurisdiction. ute the discharging water. Quick response sprinklers are intended for installation as • specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1FR56 Quick Response Upright, Pendent & Conventional Sprinklers . Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler IdentificationNumber • Orifice Size Height Organization (SS IN) US Metric Upright Pendent Standard-Upright(SSU)and pendent Deflectors Marked to Indicate Position ▪ 1/2"(15mm) 'h"NPT(R'/2) 5.6 80 2.25"(57mm) 1,2,3,4 RA14251I RA1414(1x2) Conventional-Install in Upright or Pendent Position 15mm11j 1/2"NPT(R1/2) 5.6 80 57mm 3,4 RA1475 111 cULus listed corrosion resistant(Polyester coated)sprinkler. (2)Polyester coated FM approved sprinkler. . S ° a 111 Upright Pendent Conventional • Model F1FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) 1/2"(15mm) 1/2"NPT(R1/2) 5.6 80 2.25"(57mm) RA1414 (I) Refer to escutcheon data table for approvals and dimensions. f 2 5/6"DIt (66.7mmf 2 I/< HOLE 2A HOLE IN CEILING [sLzmm) —2 S/I6'DIA (56.7mr4 I Is/Is'aw CUP (/s.2mmI _ I-K V2'R£DOC£R I I I"X I/26REDUCER TURN COLLAR IT Ti UNTIL no-or AGAINST SPRINKLER I I I WRENCH BOSS I, l 0_) I \ 1 1 �iJJ II r —� ( I ILA- J—Y/���J L -- J fU _�L '=_� �� 71 >7 FACE OF FITTING ro CEDING � ADJUSTMENT(I) 11 CEILING yyDMIENSION I���r�J,�rl ���1%�� t \�` �(ill! �� iqIiI TO FAC OF FIT77NG EE OF CEILING %III�� l VD' 2m I�I I�I DIMENSION 11 4illito ADJUSTMENT .A. 2 22/32'DN. OTAFCOJ -"'..... -- [122mmJ t ViffIX11 TO REFER TO FT A F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS (I) REFER TO FP ESCUTCHEON MTA TABLE FOR APPRONILS AND DONS. Model F1FR56/F1 or F2 Model F1FR56/FP 2. • Model F1 FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal K Factor Sprinkler Nominal Sprinkler Approval Orifice Thread Size US Metric Height Organizations Identification Numbers (SIN) Y"(15mm) 1/2" NPT(R1/2) 5.6 8.0 2.25"(57mm) 1,2,3,4 RA1485 15mm Y2" NPT(R1/2) 5.6 8.0 2.25"(57mm) 407 (I)LPC Approval is for pendent position only. Sprinkler Type Deflector to Ceiling Distance (Min. -Max.) Upright 4"(102mm)-12"(305mm) Pendent 4"(102mm)- 12"(305mm) Vertical Sidewall Model F1FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Height and Type of Approval Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Hazard Numbers(SIN) 1/2"(15mm) 1/2"NPT(R1/2) 5.6 80 2.63"(67mm) 1,2 1 RA1435 FACE OF F7TT1NG(1J TO FACE OF CEILING DIMENSION 1 1/4"MIN. [31.8mm] 2 7/4"HOLE DIA. 7/8. 4'--12' [57.2mm] [32mm] [101.6mm-304.8mm] CEILING TO 1"X 1/2"REDUCER DEFLECTOR �a w7 7 15/16"DA.' I� [49.2mm] --- ---- 2 27/32" OW. 1 Il_ t [722mm] Horizontal Sidewall TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. ADJUSTMENT(7) 01=034 (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. • (2) FM APPROVED FOR 4' - 6'1-101.6MM - 152.4MM] CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. 3. Model F1FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal "K" Factor Thread Temp. Rating Max. Bulb Sprinkler Orifice Size Model Ambient Color Approvals Identification US Metric Sprinkler Cover Temp Number(SIN) 1/"(15mm) 5.6 80 1/2"NPT F1FR 135°F/57°C 135°F/57°C 100°F/38°C Orange 1,2 RA1414 - 1/2"(15mm) 5.6 80 1/2"NPT F1FR 155°F/68°C 135"F/57°C 100°F/38°C Red 1,2,4111 RA1414 1/2"(15mm) 5.6 80 1/2"NPT F1FR 175"F/79°C 165°F/74°C 100°F/38°C Yellow 1,2 RA1414 1/2"(15mm). 5.6 80 Y" NPT F1FR 200°F/93°C 165°F/74°C 100°F/38°C Green 1,2 RA1414 (')For VdS only=155°F/68°C Norbulb and 1/2"[12,7mm]adjustment. 1"x 1/2"REDUCING TEE OR ELBOW I"x I/2"REDUCING _ —..—..—_—.- '-17----- TEE OR ELBOW 4 _..—..—.. .r i - m 1f-------- 1-, r-L 2 5 6"DIA. —�__--.11 i ll.-----..�-- 2 5/16" DIA — HOLE IN CEIUNG , —I— ti J HOLE IN8"DIA. EILING CUP t�- 1� I 2 5/16"DIA — - 1 1/2"MAX. CUP t --yt• I A II�Ir �llll FACE OF FITTINGI II[•.51.1111�1� 1 1/2" MAX. I lI JTO FACE OF CEILING FACEOFFITTING1 ' '� I�II�III T,,77777 DIMENSION -; II' I+I T_ _ __ TO FACE OF CEILING p I ,,,,,,,_ + 3' 1 �lpll��I 0/MEI�SION CEILING ��.: j •, •�I�`/l — : __.'= 1 (� ��b CEILING \�l,�I� 7/2" MAX. T 15/76" ER AO STM. T ::: 3/4„ COVER ADJUSTMENT COVER 6"MAX. COVER PLATE— t COVER PLATE— f ASSEMBLY 3 5/16" DIA. - ASSEMBLY S 5/16"DIA. SPRINKLER—/ SPRINKLER 1/2" ADJUSTMENT 5/16" ADJUSTMENT oosixa Figure 1 Figure 2 _ Installation Aid A protective cap is included for use during installation. Sprinkler with a threaded Model CCP cup which is fac- important: The F1FR56 Sprinkler with Model CCP cover tory attached to the sprinkler. The assembly is complet- plate is not an FM Approved combination. ed by the installation of the attractive, low profile, 135°F Installation (57°C) or 165°F (74°C) rated Model CCP push on cover Quick response sprinklers are intended for installation plate assembly. The cover plate and sprinkler cup as- as specified in NFPA 13. Quick response sprinklers and semblies are joined using a cover plate skirt with flexible standard response sprinklers should not be intermixed. tabs for threaded engagement. A choice of two cover The Model F1FR56 Recessed Quick Response Sprin- plate assemblies provide either 1/2" (13mm)or She" (8mm) klers are to be installed as shown.The Model F1 or F2 Es- of cover adjustment. cutcheons illustrated are the only recessed escutcheons Do not install these sprinklers in ceiling which have to be used with the Model F1FR56 Sprinklers. The use positive pressure in the space above. of any other recessed escutcheon will void all approvals After a 25/e" (67mm) diameter hole is cut in the ceil- and negate all warranties. ing, the sprinkler is easily installed with the Model RC1 When installing Model F1FR56 Sprinklers, use the Mod- Wrench. A Teflon* based thread sealant should be el D Sprinkler Wrench. Use the Model GFR2 Wrench for applied to the sprinkler threads only. The Model RC1 installing F1FR56 Recessed Pendent Sprinklers. Any Wrench is then used to engage the sprinkler wrenching other type of wrench may damage these sprinklers. surfaces and to install the sprinkler in the fitting. When NOTE: A leak tight 1/2" NPT (R1/2) sprinkler joint can inserting or removing the wrench from the sprinkler/cup be obtained with a torque of 8-18 ft-lbs(10,8-24,4 N-m). assembly, care should be taken to prevent damage to Do not tighten sprinklers over maximum recommended the sprinkler. DO NOT WRENCH ON ANY OTHFR PART torque. It may cause leakage or impairment of the sprin- OF THE SPRINKLER. The cover plate is then pushed "klers. onto the cup. Final adjustment is made by hand turning The Model F1 FR56/CCP Concealed Sprinkler uses the the cover plate until the skirt flange makes full contact 1/2" orifice, 1/2" NPT (R1/2), 135°F (57°C), 155°F (68°C), with the ceiling. Cover plate removal requires turning in . 175°F (79°C) or 200°F (93°C) Model F1FR56 Pendent the counter clockwise direction. *DuPont Registered Trade Mark 4. After installation, inspect all sprinklers to ensure that Sprinkler Types there is a gap between the cover plate and ceiling and Standard Upright that the four cup slots are open and free from any air flow Standard Pendent impediment to the space above. Conventional Concealed cover plate/cup assemblies are listed only Recessed Pendent • for use with specific sprinklers. The use of any other con- Vertical Sidewall . cealed cover plate/cup assembly with the Model F1FR56 Horizontal Sidewall Pendent Sprinkler or the use of the Model CCP Concealed Recessed Horizontal sidewall cover plate assembly on any sprinkler with which it is not Concealed pendent specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Maximum Working Pressure Glass bulb sprinklers have orange bulb protectors to 175 psi (12 bar) minimize bulb damage during shipping, handling and 100% Factory tested hydrostatically to 500 psi (34.5 bar) installation. REMOVE THIS PROTECTION AT THE TIME Finishes (1) THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this Standard Finishes Sprinkler Escutcheon Cover plate time may leave the bulb vulnerable to damage. RASCO Bronze Brass wrenches are designed to install sprinklers when covers Chrome Plated Chrome Chrome are in place. REMOVE PROTECTORS BY UNDOING THE White Polyester Plated White CLASP BY HAND. DO NOT USE TOOLS TO REMOVE Coated(4xs) White Painted THE PROTECTORS. Special Application Finishes Sprinkler Escutcheon Cover plate Temperature Ratings Bright Brass(3) Bright Brass Bright Brass Sprinkler Black Plated Black Plated Satin Max.Ambient Black Paint Black Paint Off White Classification Temperature Temp. Bulb Color °C °F Off White(2) Off White Black Paint Satin Chrome Satin Chrome Black Plated Ordinary 57 135 100°F(38°C) Orange (" Other finishes and colors are available on special order. Ordinary 68 155 100°F(38°C) Red Consult the factory for details. Intermediate 79 175 150°F(66°C) Yellow (2) cULus Listed only. Intermediate 93 200 150°F(66°C) Green (3) 200°F(93°C)maximum. High r'r 141 286 225°F(107°C) Blue c<) cULus listed"corrosion resistance"applies to SIN Numbers . ''"Not available for recessed sprinklers. RA1425(Upright)and RA1414(Pendent)in standard black or white. (5) FM Approvals finish as"Polyester coated"applies to SIN Number Escutcheon Data (1) RA1414(Pendent)in standard black or white. ApprovalsFace of Escutcheon acQustmeru Fitting W sly° Ordering Information Model Dimension Dimension Specify: Max Recess 11/2"(38.1mm) 3/16"-15/16" 1. Sprinkler Model F1 1,3,4 Min Recess 3/4"(19.1mm) (5mLm-24rrm) 2. Sprinkler Type F2 1,2,3,a Max 1'/z (38.1mm) 3/,6 /16" 3. Orifice Size Min Recess 1 (25rrrn) (5mm-17mn) 4. Deflector Type FP Push- 1 4 Max Recessed 7/6"(11mn) 1'12"(38.1rrm) Thread-off Min Recessed t5/16(24mn) 1"(25.4rrrn) 5. Temperature Rating ")SIN:RA1435-cULus and FM permits use with F1 or F2 escutcheons for light 6. Sprinkler Finish hazard only. 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Maintenance 9, Cover plate Model The Models F1FR56 and F1FR56 Recessed Sprinklers 10. Cover plate Thread size should be inspected quarterly and the sprinkler system 11. Cover plate Temperature maintained in accordance with NFPA 25. Do not clean 12. Cover plate Adjustment sprinklers with soap and water, ammonia or any other 13. Cover plate Finish cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has Note:When Model F1FR56 Recessed sprinklers are ordered,the sprin- been painted (other than factory applied) or damaged klers and escutcheons are packaged separately. in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. 5. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gaugesldentification signs • Electrical sprinkler alarm switches • Fire department connection • Water flow detectors The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly • qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. - Manufactured by The Reliable Automatic Sprinkler Co., Inc. a Recycled Reliabld (800)431-1588 Sales Offices Paper (914)829-2051 Sales Fax Corporate Offices Revision lines indicate updated or new data. (914)829- 042 www.reliablesprinkler.com Internet Address EG.Panted in U.S.A 02/11 PAN 9999970300