Loading...
Reportr . 7409 SW Tech Center Dr,Ste.145 Tigard,OR 97223 1111=0 '°`"sTS Ph:503-443-3799 Fax:503-620-2748 OILS 503.443.3799 Special Inspection Final Report Date: November 14,2019 Job#19-8626-24 Permit#BUP2019-00278 Mail To: Project: ENGINEERED PRODUCTS a PAPE' CASCADE WINDOW COMPANY 6713 SW BONITA SUITE 2701 9800 40TH AVE S. TIGARD,OR 97224 SEATTLE,WA 98118 PO#95024 To Whom It May Concern: ACS Testing, Inc.attests that their inspectors performed special inspection(s)on a continuous and/or Periodic basis as required by the specific jurisdiction and/or IBC. Special inspection(s)were performed for the following: Anchors-Expansion Based on personal observation, inspection and reports reviewed by me for the above project, I attest on behalf of ACS that work was performed to the best of my knowledge, in accordance with approved plans, specifications,and the applicable codes and standards for the jurisdiction. Approved by: �k.-- Bob Brown/President BB/KS / e- Proud to be Nationally Accredited by International Accrediting Service ACCREDITED 7409 SW Tech Center Dr.Ste. 145 Tigard,OR.97223 ariuu Ph:503-443-3799 Fax:503-620-2748 c ""E DAILY FIELD REPORT FOR PROPRIETARY ANCHORS a� TESTING, INC a03. 1,i.3799 Date: Nov 13, 2019 Permit#: BUP2019-00278 ENGINEERED PRODUCTS a PAPE' CASCADE WINDOW COMPANY Continuous 6713 SW BONITA SUITE 2701 9800 40th AVE S. TIGARD, OR 97224 SEATTLE, WA 98118 Periodic n PO#95024 Inspector/Certification# Jerry Frampton Cert#OBOA 859 ACS Job# 19-8626-24 Anchor Embedded in: Concrete Is this a re-inspection?: ❑ Yes ❑✓ No Compressive Strength: EXISTING UNKNOWN Approved plans available?: ❑✓ Yes ❑ No HOLE DETAIL/CONDITION Work acceptable per approved n Yes El No plans?: Size:Anchor 1/2" Hole 0: 1/2" Embed 3-1/2" Installation complies with Depth: manufacturer's evaluation report?: n Yes ❑ No Holes cleaned properly?: ❑✓ Yes No LOCATION OF ANCHORS Embedment per plans?: El Yes ❑ No GRIDLINES New racking base anchors INSTALLATION GRIDLINES ESR REPORT# GRIDLINES ESR-1917 TZ CARBON&STAINLESS in CONCRETE ANCHOR TYPE: WEDGE ANCHOR IS THERE AN RFI? ❑ Yes Q No RFI ATTACHED? EPDXY TYPE: N/A ❑ Yes 7 No INSPECTION DETAILS: EXP. DATE: N/A ACS representative on site for inspection of installed mechanical anchors for new racking base connections per the approved racking details, no revision. All required anchors were installed and met the manufactures published installation torque requirements. No issues noted. Foreman notified of ❑ Yes Li No ❑✓ N/A nonconformance items? Foremans Name: Reviewed ,c),)( Date: cc: 11-14-2019 Bob Brown, President BB/JF ACS-1 I s7 ACCREDITED