Report Mr. Cory Borne March 12, 2020 of *. Site Inspection Page 12 10635 SW Cook Ln Tigard, OR • on the upper shaft onto the anvil. The underlying soil strength is determined by measuring the penetration of the lower shaft into the soil after each hammer drop. The number of drops required for a penetration of 4" is then recorded and converted to an equivalent SPT N-values which is reported on the attached boring log (DC-1). The DCP boring extended to a depth of thirteen feet (13'-0") below grade. The upper six feet (6'- 0")of soil consists of soft to medium stiff material. Between six feet (6'-0")and nine feet(9'-0"), a stiff to very stiff layer of material was found. Between nine feet (9'-0") and thirteen feet(13'-0"), a medium stiff to stiff layer of material was found. The DCP boring log (DC-1) is attached to this report. A test pit was excavated on March 4, 2020 adjacent to the footing. The test pit extended to a depth of three feet (3'-0") below the foundation grade beam. The upper two feet (2'-0") of soil consisted of soft to medium soft brown clayey silt, followed by a layer of medium stiff to stiff brown clayey silt, which was encountered to the termination depth at three feet(3'-0"). RECOMMENDATIONS It is our opinion that the settlement is the result of improper foundation drainage and/or undersized foundations.We understand that helical piles are proposed to underpin portions of the north,east, and west sides of the residence. A hydraulic torque driver head is used to install the helical pile. Advancement of the pile will continue until the minimum installation torque is achieved as specified by the torque correlation method to support the allowable design loads of the structure using a torque factor. We recommend that the proposed piles achieve a minimum embedment depth of seven (7)feet. However, it is anticipated the actual pile embedment depth may be greater. The repair work will not interfere with the existing lateral support conditions. Therefore, there are no lateral design concerns. Maintaining uniform moisture around the foundation is very important. The landscape grades around the residence should be maintained to slope away from the residence where required. The landscape grades should slope away from the foundation at a minimum of 1/2" per foot for six (6'-0)feet.The top soil should extend a minimum of one(1'-0)foot above the bottom of the footing and should not extend above four(4")inches below the bottom of the siding.All new fill soil should be clayey sand with a minimum Plasticity Index (PI) of twenty-five (25). Watering the soil around the foundation is also important during dry periods to help maintain uniform moisture in the soil. This report is for the sole use of Ram Jack West and their design consultants for the foundation repair at the referenced site. Northwest Engineering Group assumes no responsibility or liability for any engineering judgement, inspection or testing performed by others outside the scope of this report. Our services do not include any survey or assessment of contamination or potential contamination of the soil or ground water by hazardous or toxic substances. No warranty is expressed or implied by this report. This concludes this report. If I can be of further assistance or should you have any questions about this report, please do not hesitate to contact me. P.O. Box 10393/ Eugene, OR 97440/541.393.7363/WWW.NWENGGROUP.COM 4 Mr. Cory Bome March 12, 2020 Site Inspection Page 13 10635 SW Cook Ln Tigard, OR Sincerely, /7 4, DPROpSs OINEc'P % 9f ,4�j//88 1. Za 01. 'fOE STEER. EXPIRES: 6943Q� Sean Morrison, E.I.T. Charles Steffensmeier, P.E. Engineering Technician Civil Engineer Attachment: Site Plan (SK-0) Dynamic Cone Penetrometer Test(DC-1) P.O. Box 10393/ Eugene, OR 97440/541.393.7363/WWW.NWENGGROUP.COM , ' ►. 98.1' +/- . i DETACHED GARAGE i I I I 10635 SW COOK LN + ++ I _ TP-1 DC-1 I �. all. �r r I Il 14.4' +/- I I ENTRY PROPERTY ccd"' I (!"'LINE L _ _ _ _1 98.1' +/- S4,R�D PROFeSS SITE PLAN �v, 101 NFF io I.. 58..• r 1/7 Am TREE PRESERVATION NOTES: { S4F Q 2p�a, „ 1.ALL HOLES ARE EXCAVATED NEXT TO THE STRUCTURE FOUNDATION ✓9 sTEFO- NORTH 2.THE TOTAL AREA OF EXCAVATED HOLES<25 SOFT EXPIRES: zed/el NORTHWEST CORY BOME SHEET: 10635 SW COOK LN SK"O ENGINEERING GROUP TIGARD, OR P.O.BOX 10393 SCALE: DATE: EUGENE,OR 97440 (541)393-7363 1130"=11-0 03/12/2020 .. • WILDCAT DYNAMIC CONE LOG Page 1 of 2 North West Engineering P.O. Box 10393 PROJECT NUMBER: 04117 Eugene, OR 97440 DATE STARTED: 03-04-2020 DATE COMPLETED: 03-04-2020 HOLE#: DC-1 CREW: Sean Morrison SURFACE ELEVATION: PROJECT: Con Borne WATER ON COMPLETION: ADDRESS: 10635 SW Cook Lane HAMMER WEIGHT: 35 lbs. LOCATION: Tigard. OR CONE AREA: 10 sq. an BLOWS RESISTANCE GRAPH OF CONE RESISTANCE 1 TESTED CONSISTENCY DEPTH PER 10 an_ Kg/an2 0 50 100 15( N NON-COHESIVE COHESIVE - 4 17.8 5 LOOSE MEDIUM STIFF - 4 17.8 5 LOOSE MEDIUM STIFF - 1 ft 6 26.6 7 LOOSE MEDIUM STIFF - 6 26.6 7 LOOSE MEDIUM STIFF - 5 22.2 6 LOOSE MEDIUM STIFF - 2 II 4 17.8 5 LOOSE MEDIUM STIFF - 3 13.3 ••• 3 VERY LOOSE SOFT - 4 17.8 5 LOOSE MEDIUM STIFF - 3 ft 5 22.2 6 LOOSE MEDIUM STIFF - 1 m 4 17.8 5 LOOSE MEDIUM STIFF - 6 23.2 6 LOOSE MEDIUM STIFF - 4 ft 5 19.3 5 LOOSE MEDIUM STIFF' - 7 27.0 7 LOOSE MEDIUM STIFF - 6 23.2 6 LOOSE MEDIUM STIFF - 5 ft 6 23.2 6 LOOSE MEDIUM STIFF - 5 19.3 5 LOOSE MEDIUM STIFF - 6 23.2 6 LOOSE MEDIUM STIFF - 6 ft 10 38.6 11 MEDIUM DENSE STIFF - 12 46.3 13 MEDIUM DENSE STIFF - 2 m 13 50.2 14 MEDIUM DENSE STIFF - 7 ft 16 54.7 15 MEDIUM DENSE STIFF - 14 47.9 13 MEDIUM DENSE STIFF - 23 78.7 22 MEDIUM DENSE VERY STIFF - 8 ft 16 54.7 15 MEDIUM DENSE STIFF - 20 68.4 19 MEDIUM DENSE VERY STIFF - 13 44.5 12 MEDIUM DENSE STIFF - 9 ft 16 54.7 15 MEDIUM DENSE STIFF - 12 41.0 11 MEDIUM DENSE STIFF - 13 44.5 12 MEDIUM DENSE STIFF - 3 m 10 ft 12 41.0 11 MEDIUM DENSE STIFF - 14 42.8 12 MEDIUM DENSE STIFF - 12 36.7 10 LOOSE STIFF - 10 30.6 8 LOOSE MEDIUM STIFF - J1uf 12 36.7 10 LOOSE STIFF Gy£p •RQF 33.7 9 LOOSE STIFF �s 30.6 8 LOOSE MEDIUM STIFF f"• NEF, spy 42.8 12 MEDIUM DENSE STIFF - }� 5 Yr 45.9 13 MEDIUM DENSE STIFF 88' ,! 16 49.0 13 MEDIUM DENSE STIFF if ft ,/� 49.0 13 MEDIUM DENSE STIFF 4 ! • - -.• a 'PeF v F 30 20�°' t`4 7 CAW ow,ne u+slwstIwc w_ si.Xls 5 S�Oe SrEFF*N EXPIRES: di'4��f/