Loading...
Plans (40) M EC2017-00476 2 of 2 A 3/4" 120°R—\ COPYRIGHT 2017 This document is an instrument of service,and �1" 130° as such,remains the property of the Architect. Permission for use of this document is limited and can be extended only by written jj agreement with vega architecture IIc AQUA 1 `�-THERMOMETER GAS LOAD SUMMARY STAT = _ -�' 4" CONCENTRIC 1" DCW CP-1 VENTS SUPPLY OPERATING MINIMUM REQURIED AIR GAPS : 2009 IPC & UPC N BATHROOM AND MOP lit �/ -3/4" 120°R- - - - —I. .......--CHECK VALVE (TYP) gir=b Natural Grocers PEAK MBH PRESSURE - --' / ° - 1 , MINIMUM AIR GAP SINK EF TIME CLOCK. 1 120 jl ith&FIXTURE AWAY FROM A WALL CLOSE TO A WALL COORDINATE WITH T&P VALVE I 10 119 sm (INCHES) (INCHES) ELEC CONTRACTOR DISCHARGE TO BE EXPANSION TANK RTU-1 150 3.5"WC- 14"WC LAVATORIES AND OTHER FIXTURES WITH EFFECTIVE OPENING NOT 1 1-1/2 ROUTED TO FS _ AMTROL ST-12-C boucher RTU-2 150 3.5"WC-14"WC GREATER THAN 1/2" IN DIAMETER (TYPICAL)------„,,. •,. __4 _ F-1 80 3.5"WC- 14"WC SINK,LAUNDRY TRAYS,GOOSENECK BACK FAUCETS AND OTHER FIXTURES 1-1/2 2-1/2 _-- 130° ° - ENGINEERS F-2 80 3.5"WC- 14"WC WITH EFFECTIVE OPENINGS GREATER THAN 3/4" IN DIAMETER 3/4" GAS LINE WITH 25501 west valley parkway,suite 200 F-3 80 3.5"WC-14"WC OVER-RIM BATH FILLETER AND OTHER FIXTURES WITH EFFECTIVE GWH-1 THERMA- DIRT LEG AND COCK STOR c i Olathe, ks 66061 F-4 60 3.5"WC- 14"WC OPENINGS NOT GREATER THAN 1" IN DIAMETER 2 3 (TYPICAL) 130° (BY 1" DCW phone 913.345.2127 fax 913.345.0617 WATER HEATER WH-1 76 3.5"WC-14"WC DRINKING WATER FOUNTAINS, SINGLE ORIFICE NOT GREATER THAN 7/16" \� OTHERS) project number 1718100 GENERATOR 315 7"WC-14"WC IN DIAMETER OR MULTILE ORIFICES WITH A TOTAL AREA OF 0.150 SQUARE 1 1-1/2 u 11. III_ ___kr- - I .i-i I_ _ INCH (AREA OF CIRCLE 7/16" IN DIAMETER • TWO TIME THE THREE TIME THE CIA I-1 N_ TOTAL MBH LOAD OF METER 991 3.5"WC- 14"WC EFFECTIVE OPENINGS GREATER THAN 1" DIAMETER OF THE DIAMETER OF THE _ • EFFECTIVE OPENING EFFECTIVE OPENING UNION vega DRAIN VALVE FLOOR (-n,p ) CONDENSATE COMP. SINKS (TYPICAL) SINK 1i 1-1/4" 1-1/4" LAMB'S TONGUE 90° ELBOW DRAIN LINE INSTALLED HALF GRATE DRAIN LINE iBY PC architecture IIc I 1I I IGENERATOR 1 /1 1 1 RTU-1 IF i HALF GRAT PROVIDE SEISMIC SUPPORT WHEN REQUIRED AT 315 MBH t 150 MBH RTU-2 9 4 THE UPPER AND LOWER 2/3 RD OF TANKS. 25107 genesee trail road ROOF Ili C 1 1 li+�150 MBH SIMILAR TO HOLDRITE QUICK-STRAP 24 GAUGE golden, co 80401 ,f „ „ „ �, ft „ „ „ �, MODEL Q5-50 INSTALL AS PER MANUFACTURERS 3" 1" 2" 1-1/4" DOME ; L FINISHED , L FINISHED r INSTALLATION GUIDELINES. ++I I t I I `1i1-1 F^3 3" 3" 3" STRAINER FLOOR FLOOR 303.872.0487 t1 80 MBH ./- r t l C 1 1 t l 1" I I vegaarchitecture.com 0 -- >� DOME WATER HEATER PIPING DETAIL I 1i+1 WH-1 fl" -1" 1" ++ AdMC" STRAINER • 3"- 76 MBH 2 t - i GENERAL NOTES: ' ! f 1,r RECEJ%TEJJ 1-1/4" I� 1► { NOT TO SCALE F-4 F-1 F-1 I f 1. PC SHALL BE RESPONSIBLE FOR AIR GAP NOV 1 6 2017 60 MBH 80 MSH 80 MBH DIMENSIONS IN ACCORDANCE WITH _t 4._ I LOCAL CODE AMENDMENTS AND Iil IOFIt . 3 .... JURISDICTIONAL REQUIREMENTS. !WILDING DIVISION Oi �� `'-j 2. RIM OF FLOOR SINK SHALL BE FLUSH OR ��' `��DRAIN OUTLET rCLEANOUT PLUG DRAIN OUTLET) SLIGHTLY BELOW FINISHED FLOOR COORDINATE WITH ARCHITECTURAL AND CONCRETE PAD-1PAVEMENTLEI , OTHER TRADES. PC IS RESPONSIBLE TO OR GRADE 6" L.__J . , .. .• - r MAIN LEVEL VERIFY FLUSH MOUNTING SINK WITH + e LOCAL CODES AND JURISDICTION. IF .'� ENJI UTILTIY GAS METER: 7"-10" W.C. DELIVERY FLUSH MOUNTING FLOOR SINK IS NOT =. • ` PRESSURE, 991 MBH CONNECTED LOAD. ALLOWED NOTIFY ENGINEER PRIOR TO /.--1= 220 FT TO FURTHEST CONNECTED APPLIANCE, ROUGH IN. oI 1.0 PSI PRESSURE DROP b' cmc 8" SQ. GAS SERVICE, SIZED Q MIME4" IIIII AND PROVIDED BY UTILITY SEE PLANS FOR r PIPE SIZEW I CL ii--- - le ---if• GAS RISER AND LOAD SUMMARY FLOOR SINK DETAIL GRADE CLEANOUT DETAIL NO SCALE NO SCALE NOT TO SCALE i �. co U c\I i. f..-TO BUILDING N TO BUILDING REDUCED PRESSURE SHUT-OFF WATER SERVICE ailj C\I n BACKFLOW PREVENTER VALVE (TYP) 11 WATER PRESSURE `/ r , () BASKET _ GAUGE (TYP.) H . STRAINER 4_ if i IT �� I..L O PRESSURE REDUCING BALL VALVE AND P VALVE WITH LOW FLOW BYPASS 0 3'-0" AIR GAP FITTING--�� . ;. 1. _ • `'+✓^ LOW & MEDIUM 1-1/2" �\ END OVER " PORTS IRRIGATION RPZ �`� ` FLOOR DRAIN Q ��/ TEMP �C_ Li- INTO TS m` FLOOR-END OVER d,, (V Q THE THERMASTOR SHALL HAVE AN II AQUA-STAT/ AQUASTAT TO SENSE THE TANK C�] GRADE _iiDRAIN O r /'9 SENSOR n. N t t�J TEMPERATURE. THE TANK SHALL (I) � � � _— LOCATION. NOT EXCEED 175F. IF THE TANK - - - 1A11 COORDINATE REACHES 175E THEN THE HOT GAS •■• ••■ BUILDING IRRIGATION METER PER r WITH FOUNDATION I CITY'S REQUIREMENT. REFRIGERATION4 BYPASS VALVES SHALL OPEN TO `7 ``� 44+- it I = BYPASS GAS PAST THE f + ��� eI ( "CPQ ( - _ _ _ 1 � ---_ CO 1-1J2" TO CI ty of Tigard PERMIT+ HEATCRAFT �CONTRACTOR THERMASTOR. - 0 ■ __ --- .1' ,� ( IRRIGATION ' `t' r•V@, PIanS 00 6/20/17 CONSTRUCTION \\\ �� - 1``\�•. I SYSTEM . 'T" 0_ , INTERFACE WITH ` B RTU TSTAT _,,� ��`�\ �`� PIPE SLEEVE ] Pt ` ! Date �` 11/15/17 RESPONSE TO CITY �, .� �� `THERMASTOR REFRIGERATION \� t3( /J i4f"( COMMENTS t_ TS-II-2HFAUTOMATION CAULK WATERTIGHT Z \, CONCRETE• - THRUST REVISION -° �\ °c 1 SYSTEM �, .. . .� '' , i t BLOCK �'-I O O u_ t I I OFFICE COPY I I N N Ce 1 THERMASTOR HOT 1 o BALANCING I HAS INLET SENSOR I GAS SERVICE ENTRANCE o VALVE i ,� 1 WATER SERVICE ENTRANCE SCHEMATIC i ` •f_ THERMASTOR SEQUENCE: DETAIL NOT TO SCALE �� ��' IN z�R > > t _�j,� _ ., O ��*� NOT TO SCALE `� '� ' �tPE `'. 0 0 o RECEIVER t I I I 11F_Fr - RI- 1-1 1c . - .0- t_ THE SYSTEM SHALL SENSE TANK DTI /z z �_ TEMPERATURE AND INLET HOT GAS DOUBLE CHECK BACKFLOW A l ct a' >� >, HOT GAS BYPASS DIVERTING VALVE LOW OR TEMPERATURE. IF THE TANK TEMPERATURE /PREVENTER cl J (l o .E a a •-e OREGON J` a a AS REQUIRED MEDIUM TEMP IS BELOW SETPOINT (175F AD]) AND THE 1 WITH O.S.&Y. GATE VALVES "3 4 ,�A �� o a HOT GAS HEAT SENSOR TIED INTO ,q a,.- c c TEKMAR CONTROLLER REFER TO COMPRESSORS 22 INLET HOT GAS TEMPERATURE THEN THE CONTINUOUS HOT WATER LOOP + PRESSURE GUAGE `r>vp Y 9, P�O� /� a HEATING SYSTEM DIAGRAM DIVERTING VALVE SHALL OPEN TO SEND FULL SIZE. SEE FLOOR PLAN • FLOW SWITCH HER E• I o -I - l RI" = I HOT GAS TO THE THERMASTOR. FOR ROUTING AND SIZE. -�•.. 4 t COMPRESSOR ROOM I ■ I.N. I_I 1 1 a I •m FP EXPIRES: 12�13i ite q 0 L 3 �� FP TO REMOTE FIRE - U HEATCRAFT (AIR RECLAIM COIL) SEQUENCE: CONTINUOUS HOT DEPARTMENT 2" MAIN o REFRIGERATOR L N WATER LOOP FULL SIZE. �I I +f1 EVAPORATORS CONNECTION SYSTEM o/ FOR REFERENCE ONLY. REFRIGERANT PIPING THE HEATCRAFT DIVERTING VALVE SHALL SEE FLOOR PLAN FOR �- DRAIN TO _ 15 co a DESIGN REMAINS THE RESPONSIBILITY OF THE BE INTERLOCKED WITH THE ROOFTOP HVAC ROUTING AND SIZE. --��� 1 SPRINKLER o REFRIGERATION SYSTEM CONTRACTOR. o: SYSTEM z N. c .a UNIT THERMOSTAT. UPON A CALL FOR ° ° -1—� i� o j = o N EXTEND TO SINK CHECK VALVE _ - _ -- - ---c-- _ - a STAGE ONE HEATING FROM THE STAT THE N N FAUCET /�� DIVERTING VALVE SHALL OPEN AND SEND - _ 2"�„� 1 BALL DRIP DETAILS -,.— o HOT GAS TO THE RECLAIM COIL. STAGE O o GRADE MECHANICAL AND _x TWO HEATING CALLS SHALL ACTIVATE THE FLOOR DRAIN r LOWER LEVEL 4:-.:ROOFTOP HVAS UNITS INTERNAL HEATING +I f ELECTRICAL CIRCUITS. + i BUILDING SAN C..; cn WHEN THEIR IS A CALL FOR HEATCRAFT FOUNDATIONS li HEATING OR THERMASTOR THEN THE a • DIVERTING VALVE FOR EITHER OR SHALL CONNECT 1/2" DHW -i: SBI Z F- I OPEN. IF BOTH PIECES OF EQUIPMENT CALL WITHIN 10" OF STOP. I _'- in �'a w WATTS MMV MIXING —' 0 FOR HEAT THEIR VALVES SHALL OPEN _ _- -z • VALVE I i I...............„.•,-CONCRETE THRUST BLOCK o WITHOUT OVERRIDING THE OTHER. ANGLE STOP TYPICAL. Z'—Fp �/� ,/ Q m • a,'; :n Opo CL •• t13 BMM QJ LIJw • _ - Z Lr_ 0' m I- Q 0 0 SUGGESTED LOW AND MEDIUM DOMESTIC HOT WATER LOOP 1.0 FIRE PROTECTION ENTRANCE DETAIL E4 . 1 °f a ,, C E . � o REFRIGERANT DIAGRAM CIN SERIES) SINK CONNECTION DETAIL NOT TO SCALE I NOT TO SCALE NOT TO SCALE 1 N