Loading...
Plans (13) BU P2019-00129 dip • D E 111 RFC;FIVED 1\11\Y 2 2 2019 ARCHITECTS M I M L CITY OF TIGARD 720 NW Davis 503.221,1121 g L U1LDI\fG DIVISION Suite 300 503 221.2077 D Portland OR 97209 www.Irsarchitects.com OFFICE COP( FANNO CREEK BLDGm B REVIEWM) F9R CODE COMPLIANCE ' . tS10 16083 SW UPPER BOONES FERRY RDa y SUITE 250 (,...yrr: NI,J i , 0 : �n } Permit #: ,,..a r2l r� ✓ --if/L-8 .:. �, * ,t' (. !".. rrte : ,,. TIGARD OREGON 97224 • w PERMIT SET 05a22N 19 CONSULTANT: PROJECT DIRECTORY PROJECT SUMMARY CODE SUMMARY (SEE EGRESS PLAN BELOVIO LEGEND (SEE EGRESS PLAN BELOW) VialIDITY THE ISSUANCE OF A PERMIT BUILDING MANAGER: I. GENERAL INFORMATION: EGRESS PATH IN ALL PUBLIC AND TENANT SPACES. SAcIIED ON 'COUSTV'1CT`ION Colliers International Monique Clouser:Monique.Clouser@colliers.com AREA OF WORK: MINIMUM INTENSITY SHALL NOT BE LESS THAN 1 REQUIRED EXITS PER SECTION 1016// AREA OF WORK DL,'_;11,I;' AND H@. 851 SW Sixth Avenue, Suite 1200 ,Rfim _ 44"MIN. EXIT EGRESS PATH r ,`,` "i PI-LEVE.NT PROJECT NAME: GOOD LIFE CO. TI. TENANT AREA: +/-,5,997 R.S.F. FOOTCANDLE AT FLOOR LEVEL ALONG THE ENTIRE OCCUPANCY SPRINKLERED REQUIRED PROPOSED - _ ,�r:y;;;�T„g'�.+ I_ PROJECT ADDRESS: 16083 SW UPPER BOONES FERRY TOTAL TENANT OCCUPANT LOAD:80 LENGTH OF THE PATH. CONNECT TO BUILDING T,`�T C;= ' (,:m: sCIAR. FROM Portland, Oregon 97204 ROAD ELECTRICAL SYSTEM. B Y 2 3 B OCCUPANCY GROUP , ,,, . L.-: cr..pfulE.cmoN Telephone (503)684-6000 SUITE 250 IV. ADA ACCESSIBILITY UPGRADES: OF Es.; ,;x.-„y,, U;:SC 1 05.4 5. PROVIDE EXIT SIGNAGE. EXIT SIGNAGE SHALL BE X ROOM OCCUPANT LOAD PER SECTION 1004 TIGARD, OREGON 97224 CONNECTED TO BUILDING POWER SUPPLY WITH PROPERTY ID: W248495 1. BUILDING HAS BEEN UPGRADED ACCORDING TO THE BATTERY BACK-UP FOR MIN 1-1/2 HOUR DURATION. I MINIMUM DISTANCE ALLOWED BETWEEN EXITS PER 1015.2.1 BUILDING OWNER: ACCESSIBILITY UPGRADES LIST AS OUTLINED IN OSSC (XX) ACCUMULATIVE OCCUPANT LOAD Parkland Development, LLC Su Moran:Su@pidus.com /I, APPLICABLE CODES: 3411, 6. PROVIDE CODE MINIMUM FIRE ALARM CONNECTIONS I OCCUPANCY SPRINKLERED REQUIRED I PROPOSED 16083 Upper Boones Ferry Rd.,Suite 120 AS REQUIRED. ( B Y 56'-4” I 114'-6" UO UNOCCUPIED SPACE Tigard,Oregon 97224 2012 INTERNATIONAL BUILDING CODE(IBC) V. EMERGENCY SYSTEM STANDARDS: 7. SURVEY EXISTING CONDITIONS OF ENTIRE FLOOR 2014 OREGON STRUCTURAL SPECIALTY CODE(OSSC) THAT PROJECT OCCURS,AND PROVIDE NOT LESS EXIT SIGN w/INTEGRATED DIRECTIONAL ARROW Telephone (503)639-0108 2014 OREGON MECHANICAL SPECIALTY CODE(GMSC) THAN ONE APPROVED FIRE EXTINGUISHER WITH WHERE OCCURS AT ALL EXITS, EVERY 100'IN 2014 OREGON FIRE CODE 1. BUILDING IS FULLY SPRINKLERED(NFPA 13). MAKE RATING OF NOT LESS THAN 2A 10B/C FOR EACH 1,500 EXIT ACCESS TRAVEL DISTANCE FROM MOST REMOTE POINT PER CORRIDORS,AND IN SPACES WHERE 2 MODES OF 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE CODE MINIMUM CORRECTIONS AS REQUIRED PER S.F. OF FLOOR AREA OR FRACTION THEREOF. TRAVEL TABLE 1016.2 EGRESS ARE REQUIRED PER SECTION 1011. (REFER (OEESC) NEW PLAN. DISTANCE TO AN EXTINGUISHER FROM ANY PORTION TO ELECTRICAL DRAWINGS FOR MORE ARCHITECT: 2014 OREGON PLUMBING SPECIALTY CODE (OPSC) 2. IN BUILDINGS WITH EXISTING SMOKE DETECTORS: OF THE BUILDING SHALL NOT EXCEED 75 FEET. OCCUPANCY SPRINKLERED REQUIRED PROPOSED INFORMATION). POCHE INDICATES "EXIT"TEXT SIDE 2014 OREGON ELECTRICAL SPECIALTY CODE(OESC) PROVIDE CODE MINIMUM CORRECTIONS AS PROVIDE FIRE EXTINGUISHER IN ACCORDANCE WITH B Y 300'MAX 196'-6" OF SIGN. SIGNS SHOWN IN CORRIDORS ARE LRS Architects, Inc, Peter Kim: PKim@Irsarchitects.com CEILING HUNG. SIGNS SHOWN ON WALL ARE WALL 720 NW Davis, Suite 300 2009 ANSI A117.1 REQUIRED, SMOKE DETECTORS TO BE TIED TO THE CURRENT CODES. PROVIDE NEW FIRE EXTINGUISHER HUNG. BUILDING ALARM SYSTEM. AT ALL EXISTING CABINETS WHERE MISSING. ALL Portland,Oregon 97209 /II. BUILDING STANDARDS: REUSED EXISTING FIRE EXTINGUISHERS ARE TO BE 3. IN BUILDINGS EQUIPPED WITH AN EXISTING VISUAL COMMON PATH TRAVEL DISTANCE FROM MOST REMOTE POINT REQUIRED EXIT Telephone(503)221-1121 STROBE SYSTEM:PROVIDE CODE MINIMUM INSPECTED AND/OR RECHARGED, AS NECESSARY, BEFORE 2 WAYS PROVIDED PER TABLE 1014.3 BUILDING TYPE: TYPE II-B CORRECTIONS AS REQUIRED. IF A SYSTEM DOES NOT JUST PRIOR TO SUBSTANTIAL COMPLETION. BUILDING OCCUPANCY: B- OFFICE BUILDING EXIST, DO NOT ADD ONE. OCCUPANCY SPRINKLERED REQUIRED I PROPOSED GENERAL CONTRACTOR: TOTAL BUILDING FLOOR RENTABLE AREA: +/-49,963 S.F. 4. PROVIDE EMERGENCY EGRESS LIGHTING FOR THE B Y 100'MAX 53-10" Built Environments Northwest Mike James: mikej@BE-nw.com 135 E Hereford Street Gladstone,Oregon 97027 Telephone(503)650-44086 PROJECT NUMBER: 219121 Good Life Co. T.I. UNDER SEPARATE PERMIT DRAWING MECHANICAL SYSTEMS SHEET NAME ELECTRICAL SYSTEMS(INCLUDING EGRESS LIGHTING) MINIMUM DISTANCE ALLOWED BETWEEN EXITS AREA OF WORK Fenno Creek I PLUMBING SYSTEMS PER SECTION 1015.2.1 EXCEPT.2(SPRINKLERS PROVIDED): 16083 SW Upper Boones A001 COVER SHEET FIRE ALARM ALLOWED DISTANCE: 169'-0"(TOTAL DIAGONAL DISTANCE)/3=56-4"MIN. Ferry A100 REFERENCE:ACCESSIBILITY COMPLIANCE SPRINKLER SYSTEMS ACTUAL DISTANCE= 114'-6" A201 DEMO&FLOOR PLAN / 77;7 — , Oregon 97224 A202 POWER/DATA&FINISH FLOOR PLAN A203 REFLECTED CEILING PLAN , , f---,}4( ,2 OCC/ // / 1 -- % 2 \ , ,: / ---a // // / •,,,, OF,.E O ICE, OF-CE OF //f` GENERAL NOTES / F.Y'` /� /r'_ • / las 2a7 zsa ! A301 INTERIOR DETAILS �.-�-% f oN-RO. � �� �;,..__ _ _ 4 �.� ;� THE SITE PLAN AND SUITE LOCATION PLAN ARE FOR REFERENCE ONLY, SEE ALL 1/ EXIT ACCESS TRAVEL DISTANCE FROM MOST -" ; ,„4:-. V - ' / ,>_. ". .. - / OTHER PLAN SHEETS FOR CONTRACT DOCUMENT INFORMATION. THE PROJECT Sr25s .RAFF SUMMARY IDENTIFIES SOME SPECIFIC OSSC REQUIREMENTS BUT IS NOT REMOTE POINT PER TABLE 1016.2: f: 1 ' ' ' INTENDED TO LIST ALL OSSC REQUIREMENTS, ALLOWED DISTANCE: 300'MAX. LENGTH r`'"�;;� � . (SPRINKLERS PROVIDED) - 15 OCC .' `. '27 " •PF / 2 / / ACTUAL DISTANCE= 196_6„ r,` > TM Jt OFF E /r. !���.+'`�� �/ i ,,, /"�.1 a r” ,.nr // L riT'11 II .. v i -,, ,' - ... I. r,:. a f.,.,, /_ __ _ _ ia. _ , Ti'w, a` ,. i�,v >.t .MN ''':::Y:'.77?-'�..,,, ...f ':A `', /////,,,,,,,,_,>. Fr G / /': jF i X .:�T( #.,.,m1s r.: : .. 1 ,. ) ':/( 18Y r Y, � ,` � �<:` .,° :'"` r._�, ����r�, ,., ■ ,/, �� 4 .. �..a ._. sro y>Ay ��� / / r �i �.. IBJ ',,i ."- .,� ._, :,) I"'� / / 1 / r f "��^,i'F '. / 'fes 1.1 '"., //f �.,.�. //,', /pr .� , �;, .,., ,,r fir. �. r � ', a� ^7 .,y��a .,- of u m i' `{ _ , / / 0"!CE 0 F'.E R f 4`F'CE, I rc., /.> tirgilits.,h, i ',1` ,, t yy::� a. .7s ' .kT 1 2S3 ST ./ „r�� I ,, f F i A t +..��yygri [�tit ." r , _ _ .... y, rf: 8 C» - Y tr - *.+r �/1..,:: _�', ,i*O) '- .ter_ �r� ..rte.! Y ...�.. �.�: -. `®. =x� �a, 14 L '�;r 4i.j ; �� — HALCWA HALLWAY y= w. 1 r [ 1 1►' r =� �a z �. ,� r .�-, y �. ? ,� r \- _r o evrcamrc .i - - :r ..-..-. p - #: z4 ? t,., _ + �- \.. ,\ STAIRS % C• _ __'�^ STAtRS 1erttrto S • ti i SHEET TITLE: i �T� v,, v , :. a tr r* 4 -`; r' rte' 7 , _. m • Cover Sheet 7 - 4. - . fix; s At c'ri- [� ,:j r ,, d- tirIIIII I "{�� p �'�,° �� �", �/ ,� MINIMUM DISTANCE ALLOWED BETWEEN EXITS � \`\ Beth r � '; * /', '` •. '`" PER SECTION 1015.2.1 EXCEPT,2(SPRINKLERS p +'i/ , ." y- ;> ' o PROVIDED)= 114'-6" \ \,c"u„,, rr,,`�. , 1. °�//' COMMON PATH TRAVEL DISTANCE FROM MOST �. N4,/:, \\ ; '; , '' ,' F'� '41p/ REMOTE POINT BEFORE TWO WAYS PROVIDED < � ,y+h` a \ ,/.�, ;`,w / ` t'/' 100'MAX, (SPRINKLERS PROVIDED)PER TABLE 1014.3; o n$ / «` is s`; .)// a°' r ACTUAL DISTANCE=53'_10” / � , • /,'/01./�� BY: PMK FANNO CREEK , � . ��,, DRAWN \\‘‘.. �'r' \ �� BLDG. B `� DATE ISSUE®: 05.22.19 \ The tr1t> rtD4,:4,,,,, - PERMIT SET 05.22.19 t l+qr r , - 1 N N 5 LAN ill ilk 3. SUITE LOCATION AND EGRESS PLAN iii,11,411 ,, cV A001 E 1'SCALE: NOT TO SCALE SCALE: NOT TO SCALE SCALE: 1/16"= 0" 0. a: t SHEET: 2. cv LRS Architects,Inc.a 2018 yl 1= Date: - 1-1 initials: �- GENERAL NOTES . ,... .. . . 1. ALL DIMENSIONS INDICATED ON THIS SHEET ARE CLEAR MINIMUM TO FACE OF FINISH. DIMENSIONS TO TOILET ROOM ACCESSORIES ARE TO THE CENTER ARCHITECTS LINE AS NOTED OR TO THE HIGHEST PORTION OF THE OPENING OR 720 NW Davis 503.221.1121 OPERATING DEVICE. 2. ALL ITEMS INDICATED BELOW MAY NOT OCCUR ON THIS PROJECT. SEE Suite 300 503 221.2077 D PROJECT PLANS AND ELEVATIONS FOR ITEMS THAT OCCUR. SEE ARCHITECTURAL PLANS FOR ACCESSIBILITY AND/OR ADAPTABILITY Portland OR 97209 www.Irsarchitects.com CONFORMANCE IN THE HORIZONTAL PLAN LAYOUT. 3. CONFORMANCE TO FIXTURE MOUNTING HEIGHT REQUIREMENTS ARE APPLICABLE IN ANY PUBLIC AREA OR EMPLOYEE AREA MORE THAN 1000 SF, AS THEY OCCUR PER PROJECT. 4. VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE � � WITH REQUIRED MOUNTING HEIGHTS. 441% 5. PROVIDE CODE-COMPLIANT BLOCKING WITHIN WALLS AS REQUIRED FOR PROPOSED AND FUTURE ACCESSORIES AND GRAB BAR MOUNTING FIXTURES. BLOCKING IS REQUIRED FROM STUD SPACE TO BACK OF SURFACE OF ALL ) x: C. FIXTURES INCLUDING BUT NOT LIMITED TO TUB/SHOWER ENCLOSURES. / / r 6. FLOOR DRAINS:ACCESSIBLE FIXTURES REQUIRE A CLEAR FLOOR SPACE it CONTIGUOUS OR OVERLAPPING THE ACCESSIBLE ROUTE. FLOOR DRAINS ' SHOULD NOT BE PLACED IN THIS CLEAR FLOOR SPACE. EXCEPTION: DRAINS MAY RESIDE IN CLEAR FLOOR SPACE PROVIDED DRAIN HOLES DO NOT 14�S EXCEED 1/2"DIA. MAX.; FLOOR SLOPE DOES NOT EXCEED 2%IN ANYOF ' DIRECTION;AND THE ELEVATION CHANGE AT THE DRAIN LIP DOES NOT EXCEED 1/8". CONSULTANT: PROJECT NUMBER: 219121 Good Life Co. T.1. TOWEL DISPENSER AND WASTE RECEPTACLE HAND DRYER EXIT SIGN COAT& UTILITY i SOAP 39"-41" GRAB BAR, 18"MIN TYPICAL DOOR -- HOOK Fanno Creek Bldg. B OPENING --Ar------Ar---- TO RAISED 36"MAX GRAB BAR, 42"MIN 16083 SW Upper Boones CHARACTERS 12"MAX 4"MIN ACCESSORY ZONE Ferry Rd, Suite 250 �' �` DISPENSER J.. 0 0 ' Tigard, Oregon 97224 I - d co � Z bo - 2 � Z � Z r i9 CARD a, o v - _ - U - U �/ _ ' ori READER .4. 12 ' H � o � o �, � �„ ti .• 1 , N. , j. 42"MAX • 110,........„111 - = w J ` TYPICAL AT DOOR TOILET-SURFACE MOUNT I rr< '� z �r� z r 1 TOILET ROOM MOUNTINGS it oe g Vii''"'WrP ---• ACCESSORY ZONE(SECTION 604.7) ;��„ r V ��I!1P L H" J VISIBLE SYMBOLS,EACH FIRE ALARM SIGNAL/STROBE ANNUNCIATOR PANEL IL �• r s jr0"MAX MIN. 2 1/2"HIGH OPERABLE THERMOSTAT WALL MOUNTED FIRE ti �t' EXISTING ELEVATOR 54"MAX FIRE EXTINGUISHER SIGN EMERGENCY POWER 2'-6" ELEVATOR TO COMPLY WITH MOUNTED PHONE EXTINGUISHER •► Fig. 308.2.1 Fig, 308.3.1 CALL BUTTON RECESSED FIRE OFF PUSH BUTTON AHJ.AND ADA MANUAL PULL CLEAR FLOOR SPACE CLEAR FLOOR SPACE UNOBSTRUCTED UNOBSTRUCTED 39"-41" GRAB BAR, 18"MIN STATION EXTINGUISHER CABINET ELECTRICAL OUTLET ti�, TACTILE PARALLEL APPROACH FORWARD APPROACH FORWARD REACH SIDE REACH 36"MAX GRAB BARc. ,42"MIN INTERCOM SIGNAGE O' ELECTRICAL OUTLET TELEPHONE STATION ��' ,, 1 4"TACCSS:RYONE WORK OUTLETAND —�', �' _;1 �,., 4MAX CHARACTER � 0 1 ElJo Ltio_l , Or'd.►� I1i7�i j w Qa oww ' ' zo � Z o z � zr t- 7 F �` w w w =i ice, "� Ail ►'`�� i • . O Q Q _ a ° © - 0 O Q Fz 4 to sr �/ r// ( 1✓'1 �I/ ji, ••1- Q w r w w Co w c? coV I�►� s� y I�1U`, z ..rte/ CO © `� g �' p z ¢ z M z o `7 CO CO a v O `r © m "' Q „' °' `r SHEET TITLE: >2 - 5 - O w Fig.308.2.2 h `-�� 42 J MAX r '� �� r • �� y n� •i ri•„ r•„ r. vi• �,, sReference: OBSTRUCTED HIGH FORWARD REACH f- - AAccessibility 10"MAX > 10"-24" `~ TOILET-RECESSED MOUNT TYPICAL AT ELEVATOR MISCELLANEOUS WALL MOUNTINGS 5 0 4' �+ 0 OTHER FIXTURES ACCESSORY ZONE(SECTION 604.7) LOWED IN THIS AREA 12"MIN 32"CLEAR AT w -4. ` `` �'�', • LIMITS OF PROTRUDING OBJECTS 3 1/2"MAX 3'4" X24"MIN ACCESSIBLE LL Compliance ' FOR PARALLEL - REFLECTIVE SHELF AND 12 MAX ,I o , EXCEPTIONS. 18ft 6 VERTICAL N 17"TO 25" iz a _ 1. HANDRAILS MAY PROTRUDE 41/2"MAX, APPROACH SURFACE POLE - w v 'v Ill v � 'I 15"MIN FOR 5"MAX GRAB BAR 12"MIN �. '� w M j; M I 2. DOOR CLOSERS AND DOOR STOPS / z m M I- ., FORWARD FOR FORWARD // 42 GRAB BAR cn LAVATORY&LAV z • SHALL BE PERMITTED TO BE 78' MIN w O %/ �� w IN COUNTER o DRAWN BY: PMK ABOVE FLOOR APPROACH ` APPROACH m z •'' Fig. 308.3.2 - - �`g3 Z .> - —�` ' : `. .V' c7 URINAL v INSULATE EXPOSED 8"MIN `�' SPOUT OUTLET LI, ¢ > i , ,a m0 v p 'v• SCREEN RIM .� c z_ ` • O DATE ISSUED: 05.22.19 o OBSTRUCTED HIGH SIDE REACH ICC/ANSI A117.1 2009 SECTION 308 REACH �- LAV HOT WATER RANGES(ALL DIMENSIONS ARE NOT TO SCALE) ? 8"MIN 8 Z w a,0 •1 /ii ; f- O 1-1* 1 SUPPLY AND �� zrn �^ ¢ ° v m Z sr o _ �: `� o, st -irt) m �" 18"VERTICAL h / DRAIN °' PERMIT SET X5.22.19 _ a _ M o URINAL �' 1 GRAB BAR PIPES TYP I N 0 6"M• • 11"MIN --'., "co- SIDE APPROACH `n L16-18 42"GRAB BAR i 6"MAX I_di. • 11"N'IN DRINKING FOUNTAIN(SECTION 602) MIRRORS(SECTION 603.3) SHELVES(SECTION 603.4) WATER CLOSET(SECTION 604) FLUSH CONTROLS ON WATER CLOSET-PLAN URINALS(SECTION 605) LAVATORY AND SINKS(SECTION 606) OPEN SIDE OF WATER CLOSET (SECTION 604) 1. ACCESSIBLE FIXTURE MOUNTING REQUIREMENTS PER ICC/ANSI A117. 1-2009 a SCALE: NOT TO SCALE A100 a g SHEET:N LRS Architects,Inc.©2018 E c, m 0 E Y n GENERAL PLAN NOTES A. REMOVE EXISTING FLOORING&BASE UNLESS OTHERWISE NOTED. B. PROTECT ALL ADJACENT AREAS DURING DEMOLITION&FROM DUST AND ARCHITECTS TRASH INTRUSION. 720 NW Davis 503.221.1121 -,'-- C. REMOVE BLINDS&WINDOW COVERINGS FOR REUSE.CLEAN AND REINSTALL Suite 300 503 221.2077 0 41 it PRIOR TO JOB COMPLETION. REPAIR AND/OR REPLACE ANY MISSING AND/OR V EQ EQ DAMAGED WINDOW COVERINGS TO MATCH EXISTING AS NEEDED Portland OR 97209 www.Irsarchitects.com 1 1 f.1 THROUGHOUT ENTIRE AREA OF WORK. f_ `1 1 " --z`I I— D. REMOVE AND SALVAGE FIRE EXTINGUISHERS&CABINETS FOR REUSE. I J J D r j Ll INSTALL AS REQ'D PER CODE, ( 1' — 1 f i r----1 f -s. L -f 1� i`�►�► -J. o (cl_ -__4jj E. DIMENSIONS ARE TO FACE OF WALL UNLESS OTHERWISE NOTED. ADVISE L k .___1__= 1--L.LJ z OFFICE OFFICE OFFICE OFFICE Q OFFICE ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. iy . ./ z _ I Z z C9 264 265 266 267 `� 268 ALIGN U' o r I� CONE ROOM t? Il f _ :.±: ) to N. N or N N IV'- 1_� ¢ 260 L ¢ l 1 H— ,1 ALIGN co i co co co ', F. SOUND CAULK ALL WALL/GLASS&WALL/MULLION JOINTS. , ; 15 FJa //./ ''f--- —11-1 111-- q- -i ce 2 Q 1 Z r , r Z r '�' , �} L l J_ J l_sJl IL____J l J b ,' a STAFF p ��s} B} B} BI: G. WHERE NEW DOORS, FRAMES&HARDWARE ARE PROVIDED,MATCH EXISTING gyri, ,---- STOR f 301 4, 9'-10" '�. � J BREAKI BUILDING STANDARD TYPE,SIZE, FINISH&COLOR. TOUCH UP EXISTING SYSTEM .r. I, i , r 9 262 FURNITURE FRAMES&DOORS WHERE NEEDED TO APPEAR AS NEW. 'c „� �' X6.3' ° \ / � ! Q^.e cP !s I ,L. ` 3 - - _ _ �� C� H. PATCH AREAS ADJOINING AND/OR ADJACENT TO DEMOLITION WORK TO r ` ` �% u % C A} C c} O'er CI) r IF 1 I! 1 IF T- IF 1 `m OFFICE MATCH EXISTING AND/OR NEW CONSTRUCTION. OF o COPY / 263 �—� io U 273 ALIGN II 1--- --1 II I —I OPEN II G- --I 11 1- __I N269 269 I a]�] c ii I IIII cx il I OFFICE II I Ii I A ow O �E� F 'C 270 o �- O l �m ..* 9 ,-- ,.6\s„, pt , I I I..» 1 1 6,_0„ / l \ )N i i I I I I I I 10_0„ %; F � �' h I I II I II 1 II I ,7 e 7-',-, a L. ._Li LL _l IL 11 �J_ li CLR \ t` "► j L.�__ CONSULTANT: COPY `', COLLAB. '• 257 AREA WAITING /. 7 PLAN KEYNOTES \ 258 9 1 261 a �. o G - �/ STO272 R. 1 CENTER NEW WALL ON WINDOW MULLION,TYP. SEE DETAIL 7/A301. SYSTEM ( I FURNITURE - — AL i'� HALL = / ,\ REMOVE AND RELOCATE EXISTING PLUMBING PIPE INSIDE NEW CORRIDOR NT __. _ 271 \� — - 6 _ WALL. HALL 256 i I l - - - �g� N B} N CD N ( B N l WOMEN L 4,_0„ I -1 MEN ..r II — 1- -I I- -I I1 z SUITE CLR .�- ii L � OPEN ILS b I ENTRY � OFFICE OFFICE OFFICE OFFICE OFFICE P 1 r , f) I 9 II 255 <- 254 253 252 251 �' y ,9 6\i RALAiltel JO' 4 I 711F- I _ LI 11 11 I 1 I -1 is f __ ®, 5'-5" I. 20'-10" / 10'_5" / 10'-5" 10'_5" / 10'_5' / 101-5"± fi EXISTING PARTITION = = = EXISTING PARTITION TO BE DEMO'D NEW BUILDING STANDARD PARTITION(SEE DETAIL 5/A301) SCALE: 1/8"= 1'-0" ,,,,,,..,.---- NEW BUILDING STANDARD FULL-HEIGHT HALLWAY PARTITION(SEE DETAIL 6/A301) 0 o RELITE PARTITION NEW(X ), DOOR FRAME&RELITE TYPES(SEE 3,4/A301) 0 DEMO PROJECT NUMBER: 219121 Good Life Co. TEL Fenno CreekBldg. 16083 SW Upper Boones Ferry , Suite 250 Tigard, Oregon SHEET TITLE: Demo & Floor Plan E; ‘7,-, 6A 5, 5 a 0 o 4g DRAWN BY: PMK d 3 DATE ISSUED: 05.22.19 a M PERMIT SET 05.22.19 Qa C7 cv as rn E., -0"2 fC0 O Al 0.. SHEET: A201 LRS Architects,inc.@ 2018 E m 0 +n ,- E Az a. GENERAL ELEC. & FINISH NOTES A, PROVIDE NEW FLOORING&RUBBER BASE AS INDICATED ON PLAN. [ B. REPAINT ENTIRE SUITE UNLESS OTHERWISE NOTED. ARCHITECTS C. ALL ELECTRICAL WORK IS DESIGN BUILD-ALL ELECTRICAL OUTLETS, DATA& SWITCHES SHOWN FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS. 720 NW Davis 503.22'1.1121 SUBMIT ELECTRICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO Suite 300 503 221.2077 D CONSTRUCTION. Portland OR 97209 www.Irsarchitects.com D. WHEN NEW LIGHT SWITCHES ARE ADDED TO ANY PORTION OF THE SUITE, II I --" -1 __ _I(R _ _ 1 t.,,_ ii _:-. , 1 1.- -, ar REPLACE ALL EXISTING LIGHT SWITCHES WITH NEW BUILDING STANDARD Ea a - i E—1 -•,fli OCCUPANCY SENSOR SWITCHES. _ E E tjDE E J .. L 1 1-- Aht. ___i e 1 . __.i * I E. PROVIDE J-BOX AND PULL STRING FOR TENANT-SUPPLIED VOICE&DATA. r I r I r— 1 1 r 1' ' L _1\40 ' --140' -. _jr,.gf OFFICE OFFICE OFFICE OFFICE05+ --OFFICE F. ALL OUTLETS SHOWN TO BE CONSIDERED NEW UNLESS OTHERWISE NOTED. 264 ° .4 265 ° ,,,,A 266 Cabe-. 267 714 268 „.. -- CONF. ROOM I-1 , 1 F.--- — —0 r -i_ (---- os ' C) , p, ,.., c„, OP Tr"--T—11----1=="1-1---1---r---1, S L I , / i 1 JL JLJ ( JL__J 6, ' % J.^. 7 z % STAFF VCT , _CPT-1 _, , f ' 11 # .. .-- STOR. - ' is 259 'fl'. ( 262 (j) 1 \\.\ Ni 1 OS (1)05 ..,. - II, ---------,<,------ - ED-. , so 0, _ i i i ,,,,...• , - OFFICE 1 ELEC. & FINISH KEYNOTES . r T il T Il --T---' 11--T-- HALLOF COPY cp ,273,, II L --I II [-- --IOPEN II I- --I II I- -I 269 ed 263 1-2- ri.-. PROVIDE AND INSTALL NEW FLOORING,RUBBER BASE&PAINT TO MATCH ------ \--s\--" .ed & Fl Cu) 111 0E1 N 775j: 1_ 11 EL I! i H I OFFICE II I H I re„„, ‘,..„, '-r \--:-/ EXISTING CORRIDOR FINISH. ,..s % 7 f air " --fr-,...21---- --1 0 , __ 0 H 270 11 el II (ficx H all _ 4 ,,,---;:,------- ded Jr 2-AL-- • Lin-.) , L2 \ 1, 1- ' ---„,_,-, I! ac:1;9 ii ap ii 0 I I ap PROVIDE POWER AND BLOCKING FOR TENANT-PROVIDED WALL MOUNTED TV. . „,..\\) 9 ded OPY ..--;, , ' COLLAB. - "\ ---., 1 ,-,- "N 1F- --q1 ET r0 IF -q IF q C) LL __Ii IL_ A - LI_ _ii LL A , , \ / il. ' . . 11'V li T1 17 it FIX. I I u_a_17 PROVIDE DEDICATED POWER FOR TENANT-PROVIDED COPIER(S). CONSULTANT: 257 AREA WAITING / -\\\ \ 7 i / i, 258 \-- 261 , \ -;' 1') , / \\ ' a a [,-4- PROVIDE DEDICATED OUTLET AND VENTING FOR TENANT PROVIDED ., 4101 ' 9 ,, 9 STOR. \-L-/ ADA-COMPLIANT ELECTRIC RANGE COOKTOP. PROVIDE VENTILATION PER 2014 272 OMSC SECTION 505.1 &SECTION 507.2.3 FOR DOMESTIC COOKING APPLIANCE, E HALL - PROVIDE BUILDING STANDARD SEMI-RECESSED FIRE EXTINGUISHER CABINET. 271 r f= ....'--..--' = = = IT _=__ = = 1.3= I — (',)) r) ‘„„,, lAI- PROVIDE BUILDING STANDARD ACCESSIBLE PLASTIC LAMINATE CASEWORK HALL „' \ M_,E N„ " WOMEN MEN : -Is 256 !I- — -1- HI IF T -0- - L_ __ , 1 SUITE , , 1 \- -/ WITH STAINLESS STEEL SINK FAUCET,AND ADA DISHWASHER. iLLO Il -C714 L Ji [1._ _i ENTRY , (1) PROVIDE DEDICATED OUTLET FOR TENANT-PROVIDED MICROWAVE. II OPEN os4„,e, 0 A 1 0 Alk W OS W I 250 1 II N... OFFICE OFFICE , OFFICE „,,,,,.. OFFICE .. OFFICE ,,--, I J I 14 t4 i 255 254 .W"w 253 Nogyr"- 252 IV 251 ,...--) 4. ij - 01 imit 1 - -‘, --eN --1 --1 I P ..I-- C.) „..1 7 =I i -I 1 \... . \- ,%E-L.--- 7 ' F... ,,. -77-f:, /...:4 - -1- -ll- -T-- - — 00 I ! / ,, 1/ 111 I W." 11 1 LO —I 1.1‘.4 1 IWVI '1 1 I .W, 0111= 1 1 0 i Ci) 17 I / s\ii ----;' CO ' X/ srilk FEC LEGEND . „---- S SWITCH $ SWITCH-OCCUPANCY SENSOR I. POWER/DATA & FINISH FLOOR PLAN os TELE/DATA OUTLET SCALE: 1/8"= 1'-0" C# DUPLEX OUTLET 220V OUTLET a BLANK OUTLET E EXISTING N NEW FEC FIRE EXTINGUISHER CABINET ded DEDICATED PROJECT NUMBER: 219121 Good Life Co. T.I. FINISH LEGEND CARPET BE SELECTED Fenno Creek Bldg, B CPT-1 TO 16083 SW Upper Boones VINYL COMPOSITE TILE VCT-1 TO BE SELECTED Ferry Rd, Suite 250 RUBBER BASE Tigard, Oregon 97224 RB-1 TO BE SELECTED PAINT P-1 TO BE SELECTED(GENERAL PAINT) P-2 TO BE SELECTED(ACCENT PAINT) PLASTIC LAMINATE PL-1 (VERTICALS) TO BE SELECTED PL-2 (HORIZONTALS) TO BE SELECTED SHEET TITLE: Power/Data & ,. Finish Floor Plan .v, E; (7) .- c < c.) o ., o DRAWN BY: PMK 0 E DATE ISSUED: 05.22.19 g 0 PERMIT SET 05.22.19 c., (.1 c74 c7) 1'70: A202 ._ a. SHEET: .&- LRS Architects,Inc©2018 g co ,0 c) E :S2 Q. ARCHITECTS GENERAL NOTES 720 NW Davis 503.221.1121 'P A. ALL ELECTRICAL WORK IS DESIGN BUILD-EXISTING&NEW LIGHT FIXTURES Suite 300 503 221.2077 D SHOWN FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND REPORT Portland OR 97209 wwwirsarchitects.corn ANY DISCREPANCIES TO ARCHITECT. SUBMIT ELECTRICAL PLANS TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. CLEAN&RESTORE ALL ___ . ..-7— v i i— : LIGHTS TO WORKING ORDER PRIOR TO JOB COMPLETION. I I , L ___I ,_11 ,r/ 117 I B. ALL MECHANICAL WORK IS DESIGN BUILD-EXISTING DIFFUSERS SHOWN FOR \ ,/ r 7 1 A 1 0 , P 0 I REFERENCE ONLY. VERIFY EXISTING CONDITIONS AND REPORT ANY / ' /\ I / I i 1 DISCREPANCIES TO ARCHITECT. SUBMIT MECHANICAL PLANS TO ARCHITECT 0,,,tttel°1) 44461:10._ i 0 I/ / I * ' / r///I • 0 --- .--- / \ ,/ 1 i '--- D /. ._ Z. ,... , FOR REVIEW PRIOR TO CONSTRUCTION. CLEAN ALL DIFFUSERS PRIOR TO JOB ;sr' COMPLETION. - 1 , : ri-------- _7._ _ 1 ____, .,.........1 / , S' 6* ' __ 1 1 , ' , . 1 0 C SUBMIT PROPOSED LOCATIONS FOR EMERGENCY LIGHTING,STROBES,SMOKE ,.,. i .,. 7 - 'A 17 i \/' r7 Er 7 , / 1 4 7ri DETECTION&SPRINKLERS TO ARCHITECT FOR REVIEW AND COORDINATION II 1 i it . • ,..,---- e I / { —-r 7N7: - / - -V / /1/ '1 / / N, ' / 't / PRIOR TO CONSTRUCTION. RECONFIGURE SPRINKLER SYSTEM,PER OSSC 1 / 1 ' I , / 107.3A,THROUGH SEPARATE PERMIT. • / ! - 0 I / ' / l • / I ° /'/I / \ / : ' " II 1 I II.-) / • , • ,' • / I/ 1,' / 1 1 r _1 ' i ' 7 _. it4 1 • , I 1 1 0 9.-9" L...... /re /I FT I - 1 E. RWEPH LEARCE EN AELWLLDIGAHMTASGAERDECAEDILDINEGD T_IMLAETSC&HGE:IDISTTOINGMAETUCILHDEINXGISSTTINAGNDBAURILDDTyINGPE OF 11. , 1 1 . (-9,4) ' STANDARD. .-- -I , ] . - -, 7 / -A r -A \ 70 , , / 1 / 1 / ' \l ,,Iir I / I , / I 1 , , . , / 1 / 1 AND FINISH. - , ..-'•?' __ L_ Li ' I I/ 1 1, „/ 4.____ v ,, 1 r ; t r , , V i • • • , , • / '''.44 ' ' i I F. REUSE/RELOCATE EXISTING CEILING EQUIPMENT PER PROPOSED LAYOUT AS CONSULTANT: [ 61 / 0 1 i Ii 1 , 1 1 1 i i 1 - NECESSARY.CONTRACTOR TO VERIFY AND CONFIRM WORKING CONDITION OF / aS * 1 / 1 / I 0 ALL EXISTING EQUIPMENT TO BE REUSED/RELOCATED. , , 1 v_ __I , v _i • ' 0 ; • I [1 0 m co r _ _ -- , r -A, I I- 7 1 A u- 0 0 „./ 1 // --A / 1 1 / I 1 / 1 _ 1 / F igN H ... 4 , IC 7A • , - ii' 0 , 0 7 0 = / / r C-9'-O'D C.9'-0';) I 11 1 / 0 -11 1 , , / I • 0 / / , , / I KEYNOTES U - - - . T 1 NAIN />e,,. X . . ,$ _ \ 0 REMOVE A PORTION OF EXISTING 2x4 CEILING GRID SYSTEM FROM SUITE / • --1 -4 --,..---,- ,S.--_---- 0 0 .,..„ AO • 1 , • _ , • • 1 0 : 0 0 ! 0 c SIDE AND INSTALL NEW 2x4 CEILING GRID SYSTEM TO MATCH EXISTING gI:-9_') ,,,,,,y i rio FS' ; . I -, I ' 0 CORRIDOR CEILING. ALIGN WITH CORRIDOR CEILING GRID.INSTALL 0 I ' BUILDINGSTANOARDRECESSEDcANLIGHT,TYP.STANDARD RECESSED CAN LIGHT,TYP. -- l , — _ _ , ____ _ t: II 11)1:1 , . , 1 „/ i / . -: ' , 1 / / +8+ , , ! ' 1 1 , -Ai , ii , 1 10.4t c) PROVIDE VENTING FOR TENANT PROVIDED ELECTRIC RANGE COOKTOP. ' I ] ; ; .; --I- I 1 ' 4‘41‘ REFLECTED CEILING PLAN SCALE: 1/8"= l'-0" LEGEND NEW SUSPENDED ACOUSTICAL CEILING GRID SYSTEM TO MATCH EXISTING EXISTING 2X4 ACOUSTICAL SUSPENDED CEILING XEXISTING HVAC SUPPLY PROJECT NUMBER: 219121 / EXISTING HVAC RETURN EXISTING BUILDING STANDARD LIGHT FIXTURE Good Life Cos T.1. am PROVIDE NEW OR RELOCATED BUILDING STANDARD 2x4 LIGHT FIXTURE — —I EXISTING LIGHT FIXTURE TO BE REMOVED OR RELOCATED Farm° Creek Bldg. B L_ __I'''' . .1 16083 SW Upper Boones 0 EXISTING BUILDING STANDARD RECESSED LIGHT FIXTURE Ferry Rd, Suite 250 o oir BUILDING STANDARD EXIT SIGNS(WI INTEGRAL ARROW WHERE Tigard, Oregon 97224 OCCURS) • EXISTING SPRINKLER CIA CEILING HEIGHT AFF CO EXISTING OCCUPANCY SENSOR F1 EXISTING FIRE STROBE D DEMO N NEW OR RELOCATED SHEET TITLE: Reflected Ceiling Plan -,„ 5' zz, 0 < ,..) < c, c, 3 DRAWN BY: PMK g DATE ISSUED: 05.22.19 g 5 PERMIT SET 05.22.19 .... (F9 z•-.i a; g g a.: SHEET: A203 71 LRS Architects,Inc,0 2018 E RI C4 .r. .e.- e s2 0. rms ARCHITECTS 1 41, 31-0" 1, A i„,. 3f 43" .10 A -7, 3'-0" ' "t1-1---6 L. 3'-0" fr 3-0" .0 720 NW Davis 503.221.1121 kk 4 0 Suite 300 503 221.2077 D RI X/ 8 VERTICAL A301 SURFACES, 7/' i Portland OR 97209 www.Irsarchitects.com ./ :\-/„ N.1 VCT ,, CPT \ „, 13'-10” PL-x •Pi \ • / \ \ / N / / \ \ 2 el' //._. ALIGN W/LOWER CABINETRY \ \ ”,, / \ , so ,0,i / 4, Eo / ,r, •4 .•,,, P-x 0-- --- / 4,cze dk");10 ss,._ ,- , A,,„-,..,,,,;•. •. .• -•,,k0. 0.4A-•.4'''4,..,i,,4‘4, / / / - A i\ Ei) ,-, Ank STAFF Zn /' AI P : cu . , • ', BREAK 4 4' 77— --. ------7 / = = ''N/ - — ,,7-'---- = = -N / TEMP TEMP TEMP % Pia A301 262 -, Ze) \ — 'Nt,lx"\. — —__-- :\ /‘ / / I c —2—2 ,....?. ---.-- Af- - -1- 'I HOOD --'- -z - '\\- --- ----\:- /- - N T, 4.1,, \E k F 4111310 SINGLE OPENING CD SINGLE OPENING wil-6" CD CONF.ROOM WINDOW •i. fTi HORIZONTAL FLUSH PANEL WIDE RELITE VERIFY BLDG.STANDARD .0, (REFERENCE SUITE 110 CONF. NI ,, ., ,-------------- SURFACES& 10 ROOM) OF t ,, ,, , N._ REF I: 117. , .0- 1 4 —) —1 — I BACKSPLASH, PL-x NOTES: NOTES: REF ',.i (MC) ._- - COOKTOP - I , li r „ -°- - - - REF (MC) - ONLY _ _ DW ,„ 1. ALL NEW DOORS TO BE SOLID CORE WOOD(TYPE"F")TO MATCH 1. ALL NEW FRAMES TO BE"TIMELY"(ALUMATONE)UNLESS OTHERWISE NOTED. .., - (MC) - A z A, A- EXISTING BUILDING STANDARD DOOR TYPE AND FINISH(PREMIUM 0-- - - --, - / , - - _ _ _ AND CLEAR CATALYZED LACQUER FINISH),UNLESS OTHERWISE , , CONSULTANT: , NOTED. 11 7:in En\ RUBBER 4.301 A301 A301 BASE,RB-x 1 , 2. PROVIDE NEW BUILDING STANDARD ADA LEVER STYLE DOOR o• 3`-0" .1'-6" 0 2'-7" . 1'-9" ' 2'-O" , 3'-O" . 3'-O" ,. HARDWARE. • CLR '''' ' VERIFY ''' ''' CLR ` CLR '' 41 3. ALL DOORS TO BE TYPE"F"UNLESS OTHERWISE NOTED. 1. ENLARGED PLAN - STAFF BREAK 262 2. INTERIOR ELEVATIONS - STAFF ROOM 262 3. DOOR TYPES 4. DOOR FRAMES & RELITE TYPES SCALE: 1/4"= 1'-0" SCALE: 1/4"= 1°-0" SCALE: 1/4"= 1'-0" SCALE: 1/4"= V-0" 18 GA.DEFLECTION CHANNEL PROVIDE(2)#8 SHEET METAL SECURE TO METAL DECK W./ SCREWS AT EA.BRACE 1/4"DIA.X 1-1/2"POWER CONTINUOUS ATTACHMENT TO STRUCTURAL . 20 GA,35/8"STUD BRACING TO ACTUATED DRIVEPINS INTO FRENCH CLEAT MEMBER TYP. /- STRUCTURE @ 8'-0"O.C. CONCETE FILLED FLUTES @ 18" O.C. OR#8 S.M.S INTO METAL EXISTING WINDOW MULLION .., 1,-0"U.O.N. I. SEALING GASKET CONTINUOUS 7-3" DECK©18"0.C. PROVIDE FOR 1/8"x 2"NEOPRENE W/ 7 7_PLASTIC LAMINATE AT CONTINUE 3/4"DEFLECTION. SILL BELOW ALL EXPOSED& BETVVEEN WALL&CEILING METAL CAP,COLOR TO GYP.BD.TO ‘,0 CEILING MATCH EXISTING WINDOW / i SEMI-EXPOSED SURFACES OVER 3/4" -. VERIFY HEIGHT e, ., _ SEE RCP MULLION,TYP / '-', . SUBSTRATE;SELF 1 I / , ° EDGE +„ 7-0"MIN. ,114. -- \\------ CEILING SYSTEM AS SPECIFIED 7 KWHERE OCCURS(REFER TO I [ • . PROVIDE(2)FASTENERS @ EA. '',. • BRACE STUD CONNECTION TO TOP 40 PROVIDE SOUND BATTING ABOVE ,--",_ ">, RCP) . . 4 CEILING TILES AT LEAST 2'-0"ON ' CLEAR SEALANT I . -_____ WHITE INTERIOR w/ , EITHER SIDE OF WALL 3-5/8'25 GA(3825125-18)MTL 4' ° . . ADJUSTABLE STUDS @ 24"0.C.WITH 5/Er GYP. -in TT_ SHELVES(TYP) 3-5/V 25 GA(362S125-18)MTL 3,›, ., BD.EACH SIDE. EXTEND MTL ,,. ..- .-. GLAZING ' ' PROJECT NUMBER: 219121 STUDS @ 24"O.C.WITH 5/8"GYP. ,-z,,, ..- STUDS AND GYP.BD.FULL HEIGHT PARTITIONTYPE AS :•• -' ,. . . . ° BD.EACH SIDE. PROVIDE 3"SOUND ,,•, TO UNDERSIDE OF STRUCTURE SCHEDULED,,- ° . ATTENUATION BATT INSULATION - ,--- ABOVE. PROVIDE 3"SOUND .,.. • . • FRICTION FIT IN STUD SPACE AND - \A-- -•\/\- - ATTENUATION BATT INSULATION .. I '' ... ° 4"WIRE PULLS, Good Life Co,. EL, ACOUSTIC SEALANT @ CEILING ,.,C••>' ,,--\, FRICTION FIT IN STUD(SEE NOTE ...' .. ...• BRUSHED -'-' 00. GRID. ?"), BELOW FOR MORE INFORMATION). ALUMINUM(TYP) A POWDER DRIVEN CENTER OF MULLIION TO :: . POWDER DRIVEN ANCHOR AT 2'-O"0.C.THRU MTL. ANCHOR AT 2'-0"O.C. .... :-: I THRU MIL.STUD \ )., ALIGN WITH CENTER OF PARTITION :: •• .. .. ...- 2 •• • A,,,, Fanno Creek Bldg., B 16083 SW Upper Boones STUD TRACK,UON ' -• BASE ON BOTH SIDES AS BASE ON BOTH SIDES AS TRACK,UON ,A„--------- SPECIFIED SPECIFIED - --,A - / L EXISTING SLAB, I -• -F4*--------' EXISTING SLAB .. .... . . .:.: Ferry Rd, Suite 250 •. • Tigard, Oregon 97224 .. ...I .., .. .., . BUILDING STANDARD PARTMON 6. FULL-HT WALL, TYP 7. WALL TO MULLION DETAIL 8. TYPICAL 3' HIGH UPPER CABINET *.il111+.0..a.166.64•....ma 4.44J..6.411 u . , ,. ,,,,,,,,,,,,,...,A, , . , ... y ,o u Mai y N 111.MEN u SCALE: 1/2"= V-0" SCALE' 1/2"= 1'-0" SCALE: 3"= 1-0" SCALE: 1"= V-0" 2P-1" / / CLEAR SILICONE CAULK AT SEAM / 21-1"U.0.N. (TYP) / 2'-1"U.O.N. CLEAR SILICONE CAULK AT SEAM(TYP) CLEAR SILICONE CAULK AT SEAM(TYP) / / CHROME ACCESSIBLE FAUCET PLASTIC LAMINATE COUNTERTOP&SPLASH PLASTIC LAMINATE COUNTERTOP&SPLASH AT ALL ADA COMPLIANT STAINLESS STEEL KITCHEN SINK A /r.:Kz7i!..41 y- PLASTIC LAMINATE COUNTERTOP t'er ...f"--7 &SPLASH AT ALL EXPOSED 7•:er 1 / . EALTEAVINALTEIOXNTOSVEEDRS3U7SAUCBESST&RAETDEGES(SEE / 1" OVER 3/4" SSUURBSFATCRAETSE&EDGES(SEE ELEVATION) --i94 >4 4"WIRE PULLS,BRUSHED \ - ,.,, • ,,, SURFACES&EDGES(SEE 3,---- N • - , ' ., V DRAWER , - -' - MEDIUM-DENSITY FIBERBOARD .0*------------ --- - - - - - - - - SHEET TITLE: k i MADE W/EXTERIOR GLUE. 4"WIRE PULLS,BRUSHED , 4"WIRE PULLS,BRUSHED .s%• = ,00-77v7 ---ALUMINUM(TYP) . Interior Details ALUMINUM PLASTIC. PLAMINATE AT ALL I P PLASTIC LAMINATE AT ALL b E. b -00c PLASTIC LAMINATE OVER 3/4" . -.4(7 --- sl-uEXBsPTORASETDES;sUERLFFACEEDSGEOVER 3SIE4M.,skuELPTORASETDESsUERLFFACEEDSGEOVER es' re SUBSTRATE REMOVABLE BASE . I I < '6•1 (-) CABINET DOORS W/ FULLY re;i WHITE INTERIOR wi ADJUSTABLE gi = WHITE INTERIOR w/ADJUSTABLE F. BLACK HEAT z CONCEALED EUROPEAN HINGE & . . SHELVES(TYP) SHELVES(TYP) el- PROOF WRAP 2 . . QUICK SNAP OFF CAPABILITY E<- O @ EXPOSED %) ' BASE AS SPECIFIED;REFER TO = BASE AS SPECIFIED(TYP) < PIPING ZN.1 ELEVATION ... --0g WHITE INTERIOR(TYP) 0 - < S RUBBER BASE ,-1,,. , 11 c) DRAWN BY: PMK I - 3" ,. 7;31- 1 IAI 44. , DATE ISSUED: 05.22.19 ci iiT.O.FIN.FLR s '.•,\\ 1E, 1 .T.O.FIN.FLR __,, , 1 r ,..4 F., UNDERCUT BY 1/4"FOR FLOOR y4, PERMIT SET 05.22.19 CLEARANCE CONTINUE FLOOR FINISH UNDER 0 O CABINET AT SINK,SEE FLOOR PLAN ,•74 N 0, eS 9. TYPICAL LOWER CABINET wl SINK 10. LOWER CABINET W/DRAWER & DOOR 11. DRAWER BASE SCALE: 1"= V-0" SCALE: 1"= V-0" A301 ._ )., SHEET: m r:a LRS Architects,Inc.0 2018 E el co 'A 7-- E Se" o_