Loading...
Plans rPS 269 2G -Q0032_ i/62.9v du/ 1ti Peal y Lip ( SUBMITTAL COVER SHEET Carleton Hart ' Architecture, P.C. CONSTRUCTION IV ttio ,, 10/17/2019 Received FEB 2 7 2020 Date: 10/16/2019 `'T' tl OF TIGARD This review Is for general conformance with plans and ,��.�/� get rY (�f pecifications only.Any deviations from same not clearly noted Project Name: Red Rock Creek Comm; ri�J ...i /l S�11•\rby the subcontactor/supplier have not been reviewed.Review shall not constitute a complete check or detailed dimensions or Attention: Anna Galloway count or serve to relieve the subcontractor/supplier of contractual responsibility for any error or deviation from Architect: Carleton Hart Architecture contract regeire"e"t` DATE 10/16/2019 Submittal #: 33 1100-1.0 PROJECT# 285 Spec Section #: 33 11 00 SPEC.SECTION It 33 11 00 Description: Water Distribution Piping REVIEWED BY Lisa Lipe,Project Engineer Fire Package Subcontractor: Lauzon ❑Reviewed ❑Reviewed*Comments E Rejected ❑Revise&Resubmit H Humber Design Group,Inc. ISI Approved as Noted 0 Rejected 0 Furnish as Corrected 0 Revise and Submit This review is only for general conformance with the design concept of the project and general compliance with the information given in the Contract Documents. Corrections or comments made on the shop drawings during this review do not relieve contractor from compliance with the requirements of the plans and specifications. Approval of a specific item shall not include approval of an assembly of which the item is a component. Contractor is responsible for:dimensions to be confirmed and correlated at the job-site;information that pertains solely to the fabrication processes or to the means, methods,techniques,sequences and procedures of construction;coordination of the Work of all trades; and for performing all work in a safe and satisfactory manner. Job#: CHA079 Date: 10/24/2019 By: Rocco Nguyen, El Transmitted: ❑p Procore ❑Hand Deliver 0 Email 0 Other PROJECT SUBMITTAL , 112:211. COVER PAGE BRANCH: 303 Submittal #: FIRE 33 1100 6720 SW McEwan Road Date: 10/16/2019 Lake Oswego, OR 97035 Project Name: Phone:503-622-9123 Red Rock Creek Commons Location: Tigard, OR Customer: Lauzon Contracting Contact: Laura Brown Email: laurab(a�lauzoncontracti nQ.com SUBMITTAL Spec. Section Description Manufacturer 33 11002.1 D DUCTILE IRON PIPE ZINC MCWANE 33 1100 2.1 G DR18 C900 PVC PIPE JM EAGLE 33 1100 2.2 BELL RESTRAINTS FORD 33 1100 3.11 DETECTABLE TAPE T CHRISTY NON SPEC 12GA BLUE TRACER WIRE PRO LINE SAFETY 33 11002.1 D.1 DOMESTIC DUCTILE IRON FITTINGS ZINC TYLER UNION 33 1100 2.4 A GATE VALVES CLOW 33 1100 2.2 A MEGALUGS EBAA 33 11002.1 D DOMESTIC DUCTILE IRON SPOOLS ZINC CUSTOM PIPE 33 1100 2.5 A DOMESTIC CAST IRON VALVE BOXES EAST JORDAN NON SPEC SUMP PUMP MYERS 33 1100 2.10 A MEDALLION FIRE HYDRANT CLOW 33 1100 2.10 A DOUBLE CHECK DETECTION ASSY WATTS NON SPEC TVWD VAULT SUMP GIBSON STEEL 33 11 00 2.9 CONCRETE VAULTS OLDCASTLE NON SPEC CRUSHED ROCK 33 11 00 2.10 A STANDPIPE &AUTO SPRINKLER CROKER NON SPEC V-BIO POLYWRAP MCWANE DUCTILE McWane Ductile-UT 1401 East 2000 South, Provo, UT 84606 McWane Ductile-OH 2266 South Sixth St., Coshocton,OH 43812 IRON STRONG McWane Ductile-NJ McWAN E 183 Sitgreaves St.,Phillipsburg, NJ 08865 DUCTILE Zinc Coated Ductile Iron Pipe Although zinc coated Ductile Iron Pipe may seem new to North America, it was first introduced for use in North America in the 1980's by McWane Ductile's Canada Pipe Division, which was then known as CANRON. The zinc coating forms a protective zinc oxide dielectric barrier. Zinc by-products, which are left behind after reacting in aggressive soils, form a healing protective barrier that cuts off further corrosion. Although zinc is an enhancement to protecting McWane Ductile Iron Pipe from corrosion, it does not provide stand-alone corrosion protection. Contrarily, V-Bio® Enhanced polyethylene encasement can be used effectively as a stand-alone corrosion protection system for Ductile Iron Pipe. Therefore, V-Bio® Enhanced polyethylene encasement is always the most effective form of corrosion protection for Ductile Iron Pipe. McWane Ductile Zinc Coated Pipe: • Consists of a layer of arc-applied or paint-applied, 99.99% pure zinc coating, having a mass of 200g/m2. • Has a finished layer of standard shop-applied bituminous paint in accordance with AWWA C-151. • Pipe markings shall include the word "Zinc" in the pipe markings or label required by AWWA C-151 and/or other markings as deemed appropriate by the manufacturer. • Shall comply with all applicable parts of ISO 8179 for zinc coatings. • Minor scratches in the zinc coating will not need to be repaired due to the self-healing nature of zinc coatings. Larger areas shall be repaired by field application of a zinc- rich paint, in accordance with ISO 8179, except when the pipe is to be encased in V- Bio Enhanced Polyethylene Encasement. Zinc Zinc Coating=200 g/m2 Zn+2 Compounds Zn+2 Asphaltic Shop Coat ZINC '1". ZINC CURRENT Ductile Iron TYTON0 JOINT PIPE ECHANICAL JOINT PIPE ai ////l///���///////Iffflld b7.?7.i7.7.'J.71JflTllna ,III�.�i,iiiii�i 1 A\\\\\\\\\\\\\\\\\\\\\\\\\\\N. m -- K A • e NOMINAL LAYING LENGTH \\\\\\\\\\\\\� �///////////////f: Y//////////// Tyton®Joint * J --B NOMINAL LAYING LENGTH Pipe Size Pipe Outside *Dimensions In. In. Thickness In. Diameter From To In. A B P' ' Outside * Gland*" 3 .25 .40 3.96 5.80 3.00 Pipe Thick ss Dimension In. Bolts ::II Bolts 4 25 41 4.80 710 315 Size In. Diamete •ight Gasket 6 .25 .43 6.90 8.63 3.38 I In. Lb. Weight 8 .25 .45 9.05 10.94 3.69 From To In. B J K1 K2 No. Size Length In. In. Lb. 10 .26 .47 11.10 13.32 3.75 3 .25 .40 3.96 2.50 6.19 7.62 7.69 4 5/8 3 11 7 12 .28 .49 13.20 15.06 3.75 14 .28 .51 15.30 17.80 5.00 4 .26 .41 •.80 2.50 7.50 9.06 9.12 4 3/4 3- ' 16 10 16 .30 .52 17.40 19.98 5.00 6 .25 .43 : :1 2.50 9.50 11.06 11.12 6 3/4 3 /2 18 16 18 .31 .53 19.50 22.00 5.00 8 .27 .45 9.1 2.50 11.7513.31 13.37 6 3/4 4 24 25 20 .33 .54 21.60 24.12 5.25 10 .29 .47 11.11 2.50 14.00 15.62 15.62 8 3/4 4 31 30 24 .33 .56 25.80 28.43 5.50 30 .34 .63 32.00 35.40 6.55 12 .31 .49 13.20 2.50 16.25 17.88 17.88 8 3/4 4 37 40 36 .38 .73 38.30 41.84 7.00 14 .33 .51 15.30 4.50 18.75 20.25 20.25 10 3/ 4-1/2 61 45 *Nominal laying length is 18 ft. 16 .34 .52 17.40 .0 21.00 22.50 22.50 12 4 4-1/2 74 55 18 .35 .53 19.50 3. ' 23.25 24.75 24.75 12 4 4 4-1/2 85 65 20 .36 .54 21.60 3.5: 25.50 27.00 27.00 14 3/4 4-1/2 98 85 24 .38 .56 25.80 3.50 1.00 31.50 31.50 1' 3/4 5 123 105 *Nominal laying length is 10ft. **Weight shown for regular grey cast ir.I follower glom carton bolts end rubber gasket. STANDARD DIMENSIONS AN t WE HTS OF • I LL AND SOCKET JOINT PIPE 3"THROUGH 36"PUSH-ON JOI T 1 UCTILE IRON PIPE Pipe Pressure Nominal * Wt.of Tyrone Joint Wt.Per Av r Size Class ThicknessOD Barrel g.Wt. / ////� In. psi In. In. aLb. BeIllLb.Wt.oi Lb.t PeLb. 's ' ////%ffjf T 3 350 0.25 3. r 10 7.00 185 9.20 /i.��� . /i/ / 4 350 0.25 0 10. I 9.00 225 11.30 //fffff f.. f//fff////i I B 6 350 0.25 .90 16.0 11.00 300 16.60 8 350 0.25 9.05 21.10 17.00 395 22.00 10 350 0.26 11.10 27.10 24.00 510 28.40 Thickness B Full Length'Aleight-Lb..** Safe 12 350 0.28 13.20 34.80 29.00 655 36.40 Pipe -- End 250 0.28 15.30 40.40 45.00 770 42.90 Size Under Water Class Pipe ainer As Pull 14 300 0.30 15.30 43.30 •5.00 825 45.80 In. (A21 51) T 0.D. I I. Shii d Full of Full of Lb. 350 0.31 15.30 44.70 •.00 850 47.20 Air Water 250 0. 17.40 49.30 5 10 940 52.30 6 55 .40 6.90 13.88 545 240 465 50,000 16 300 0 17.40 52.50 54..I 1000 55.50 8 55 .42 9.05 16.63 770 240 655 70,000 350 4 17.40 55.80 54.0: 1060 58.80 10 55 .44 11.10 19. . .:5 220 860 95,000 250 .31 19.50 57.20 59.00 1090 60.50 12 55 .46 13.20 :10 12 • 155 1080 120,000 18 300 0.34 19.50 62.60 59.00 1185 65.90 14 56 .51 15.30 4.50 1655 160 1410 145,000 350 0.36 19.50 66.20 59.00 1250 69.50 16 56 .52 17.'' 27.00 1990 45 1685 165,000 250 0.33 21.60 67.50 74.00 1290 71.60 56 .53 2375 I 2015 20 300 0.36 21.80 73.50 74.00 395 77.60 18 58* 59 ..50 30.00 2560 11 I 2170 195,000 350 0.38 21.60 77.50 74.00 70 81.60 56 .5' 2810 -200 2375 200 0.33 25.80 80.80 95.00 1- I 86.10 20 21.60 32.75 210,000 59* 3110 100 2635 25 0.37 25.80 90.50 95.00 17 95.80 24 56 .56 25.80 38.25 3700 -620 0 260,000 24 3 0.40 25.80 97.70 95.00 1855 103.00 6 .74 4415 95 37 . 0 0.43 25.80 104.90 95.00 1985 110.20 30 .: .71 32.00 46.25 5855 -900 4920 5 000 50 0.34 32.00 103.50 139.00 2000 111.20 61* .836435 -180 5360 200 0.38 32.00 115.50 139.00 2220 123.20 57 .78 8145 -1300 6880 4000 30" 250 0.42 32.00 127.50 139.00 2435 35.20 59* ,85 38.30 54.25 8725 -725 7330 300 0.45 32.00 136.50 139.00 2595 •4.20 350 0.49 32.00 148.40 139.00 2810 1 .10 Thickness required to overcome buoyancy. 150 0.38 38.30 138.50 184.00 2675 14:*0 **Weights listed are for 18'-0"laying lengths.Nominal full lengths vary by size. 200 0.42 38.30 152.90 184.00 2935 163.Pipe,Bell,Ball and Retainer are ductile iron. Dimensions and weights are subject to manufacturing tolerances. 3 * 250 0.47 38.30 170.90 184.00 3260 181.11 6 in.-24 in.pressure rating:350 psi 300 0.51 38.30 185.30 184.00 3520 195.50 30 in.-36 in.pressure rating:250 psi 350 0.56 38.30 203.20 184.00 3840 213.40 t Including bell;calculated weight of pipe rounded off to the nearest 5 lb. I Including bell;average weight per foot,based on calculated weight of pipe before rounding. * Tolerances of DO of spigot end:3-12 in.=+0.06 in.&-0.06 in.;14-24 in.=+0.05 in.&-0.08 in.; 30-36 in.=+0.08 in.&-0.06 in. **Fastite®Joint DIMENSIONS AND WEIGHTS FOR SPECIAL CLASSES OF PUSH-ON DUCTILE IRON PIPE LAYING CONDITIONS Pipe Nominal Wtot Tyton®Joint y� A- Size Thicknessl Thickness BB Barrel Wt of WL Per Avg.• Class In. Wt. �j - �4 In. In. Per Ft.t Lb. Bell Lb. Lgth-t Lb. Per Ft.#Lb. ,y\�, 'y ��////,,,jj �• 3 ® 0.28 t Ii i o 0.3 Oi :a1 h.0 3 � ��U0� 2.2 au D4 >./ � �� . 11, 3 1 I I 13 7 0® 4.1 ' �'� 4 ®�� 4.80 ®OIL 1.8 �'L>�4♦�� ® 4 4.80 ip i•I 3.1 Y♦ .4 ♦ 4 ®MIEMI 4,80 MEIREIIMMIIMMIRTIN 4.3 Type 1* Type 2 Type 3 Q �� 4.80 ��0 280 5.5 Flat-bottom trench.t Loose hackfill. Flat-bottom trench.t Bean lightly Pipe bedded in 4 in.(100mml 4 ®' 4.60 ®0®i 7.8 consolidated to centerline of pipe. minimum of loose soil++Backfill 6 IIIIIIII�EMI. 6.90 IMEMMIIMIBIIKIIIM 6.6 lightly consolidated to top of pipe. tiIMEiMINIIM:'IM;TI>t '=111MIMr INNM ♦�Vj� 6 ®� 6.90 �0 1 22.0 ��� � �G *For 14 in.(355-mm)and 6 �� 6.90 ®DIIIII. 9 23.a ® t •r ® �� � larger pipe,consideration 6 6.90 I0 i 25.6 4 ` ;.= should be given to the use 6 I �� 6.90 �� 490 27.3 1 ," 0 4, ; •Ok 4, N ♦ noj ,t of laying conditions other 8 ������ 23.7 . +, -,y�- +•1,. than Type 1. B ® 1 1 ®�� 26.1 ...� a�V- . " , / t"Flat-bottom"is defined as 8 MUM MN=rrili®0® 28.6 undisturbed earth. : �MI �LiMT1��IMYMII : 1 Type4 Types 8 0��®0 60D 33.4 Pipe bedded in sand,gravel,or Pipe bedded in compacted ++"Loose soil"or"select : ®IIMITIMMI IMUMEMEM MI= 35.7 crushed none to depth of 1/8 pipe granular material to centerline material"is defined as 8 IIMM WPM MI®� 0 685 38.1 diemetec 4 in.(100 mm)minimum. of pipe.Compacted granular native soil excavated from 1 I�l511=1•III3311IIIIIM= 31.4 Elackfill compacted to top of or select material++to top of the trench,free of rocks, 0 ®WMIERE ®m WPM 34.5 pipe.(Approximately a0 percent pipe.(Approximately 90 percent foreign materials,and 0 F I ' MCI MN= 37.5 Standard Proctor,AASHTD T-99.) Standard Proctor,AASHTO T-99.) frozen earth. 0 I®�F'� 39.2 �®1 40.5 0 0WIEMmiriMENIMENTIO 780 43.4 Notes: 0 ® 0.44 ®i 11E111111110IMIM 46.4 Consideration of the pipe-zone embedment 0 IIIIIMIWIEE1111®i 48 0 890 49.3 conditions included in this figure may be 2 OMERMIIOn 38.4 m®i 40.0 American Association of State Highway and ®���® 43.6 influenced by fa ctors other than pipe strength. 2 ® 1 For additional information on pipe bedding and Transportation Officials,444 N.Capitol St NW., 2 ®NICEMQt '�1 _ 850 47.2 backfill,see ANSI/AWWA C600. Suite 225,Washington,DC 20001. 2 ' 0.40 MEI IIIIMEMETIN IKIIIM 50.8 2 I0WE=IZEI MIEREIN0 980 54.4 2 MIME 0.46 MU nomMla 1040 57.9 STANDARDS APPLICABLE TO DUCTILE IRON PIPE AND FITTINGS 2 0 0.49 EMI=NM0MEM 61.5 THICKNESS DESIGN OF DUCTILE IRON PIPE ANSI/AWWA C750JA21.5D 4 �1'�� __ 900 51.0 4 ®�iI®m� 54.2 DUCTILE IRON PIPE FOR WATER AND OTHER LIQUIDS ANSI/AMA C151/A21.51 4 NISTRIIMEEMIEVEIMIXIIIMIEWECEI 58.4 FEDERAL WWP421D,Grade C 4 ®WIER=MI NVOIMENCIIIM® 62.6 DUCTILE IRON PIPE FOR GRAVITY FLOW SERVICE ANSVASTM A746 4 MIMI 11•71•1111110 mormuurimmErim 66.7 DUCTILE IRON FITTINGS FOR WATER AND OTHER LIQUIDS 4 ® 0.48 II(•T1 68.4 I0® 70.9 3 in.through 36 in, ANSI/AMA CII0/A21.10 4 MIIIMIIMMIIIIREI®0INETEI 75.0 DUCTILE IRON COMPACT FITTINGS 6 Im 1EMI8_ am 1060 5:.8 3 in.through 24 in. ANSI7AWWA C153/A21.53 6 1®�� 60.6 _ 63.6 FLANGED FITTINGS hS ANSI/AWWA C110/A21.10 6 ® 0.40 R1l�0� 63. 6 ©IMERNINIF�MIUMm® 73.1 ANSI B16.1 6 0 0.46 MFAILEIMITIMI0 1400 77.9 DUCTILE IRON PIPE WITH THREADED FLANGES ANSI/AWWA C115/21.15 6momuctrzunrcimmtmwm 1490 82.7 COATINGS AND LININGS 6 O�III1;!1]1 84.4 �® $7,4 a IM7=1111171RM UM 64.4 MIMI MEIN 67.7 Asphaltic ANSVAWWA C151/A21.51 8 ® 0.38117121 69.8 0® 73.1 ANSVAWWA C110/A21.10 8 UWE=IrEl®orriewirm 78.5 ANSI/AWWAC153/A21.53 8 10 0.44 ®i 80.6 III 83.• Cement Lining ANSI/AWWA C104/A21.4 8 IMZ=IINEEIMIPEI 86 MIEM MEM 89.3 Various Epoxy Linings and Coatings MANUFACTURER'S STANDARD 8 immcmazimrsiminommim 94.. Exterior Polyethylene Encasement ANSI/AWWA C105/A21.5 8 .1 O M 1800 100.0 JOINTS-PIPEANDolyethGS 20 1 i P g J& 27.. 20 ®����� 83.6 Push-0 n and Mechanical Rubber-Gasket Joints ANSI/AWWA C111/A21.11 20 ®�EIEI IZIM0WWII 89.6 FEDERAL WWP421D 20 ®MEEMI 21.60 iiiiiMIMMINFECM 95.6 Flanged ANSI/AWWAC115/A21.15 21 0.08 1111171=WM MIMI 1830 101.6 ANSI B16.1 20 ® N BEI MIERM0M'4.� 107.5 Grooved and Shouldered ANSI/AWMNA C606 20 0INTIMEEMEMM0 2040 113.4 PIPE THREADS ANSI 821 24 0��1�0� .; INSTALLATION ANSI/AWWAC600 24 ®� 25.80 II 01895 105.4 24 ® 0.44 EMI IMIIIIMIOWM 112. 24 1®IMMIN 25.80 MiliBEMIKIM® 119.7 24 MIEMIEVIIN 25.80 ingriE0l. 126.9 24 ®WPM 25.80 128.8 MIM MUM 134.1 VD 2' 1 !Mi 25.80 MF 1♦�� 141.2 Canada Pipe 30 0 � 11 ���}a 126.2 McWANE I IRON STRONG Company ULC 30 ®� rr ®i 0 2490 138.2 DUCTILE 30 ®� 11 ��� 150.2 30 ®MEM FEEIINEEINIMEIN MEM 162.1 NEW JERSEY OHIO UTAH CANADA 30 �� t1 ��®i 174.0 183 Sitgreaves St. 2266 S.6th St 1401 E 2000 S. 1757 Burlington St.E 30 ® 1® r r 1111��� 185.9 Phillipsburg,NJ tI8885 Coshocton,OH 43612 Provo,UT 84803 Hamilton,ON LaSt.E 30 I7 I I 190.0 �� 197.7 908-454-1161 740-622-6651 101-373-6910 7-3251 36 �� 38.30 3000 166.7 mcwaile.com mcwe2-6651ile.com mcwa3-6910le.com cen547-32e.com 36 ® 0.48 IM� 184 ® 184.7 36 MM.MN= 38.30 WEIN=ENS 202.6 36 ® 0.58 EMI MIMI 184 Man 220.5 36 MMIniiiiii. 38.30 MUM IMITNI 4290 238.3 P111"'t 36 15 0.68 ®i t 184 4610 256.1 ® ® NSF 61 .4 ®ISO 9001 DIPRA am Ramified I..o,�,, 36 56 0.73 38.30 263.7 184 4930 273.9 tlncluding bell;calculated weight of pipe rounded off to the nearest 5 lb. :including bell;average weight parka;based on calculated weight of pipe before rounding. "Tolerances of OD of spigot end;3-12 in.z0,06 in.,14-24 in.+0.05 in.,-0.O8 in.,30-38 in.+0.08 in.,-0.06 in. • ,. jam f.e z‘ BLUE BRUTETM �/ PERFORM Building essentials SUBMITTAL AND DATA SHEET y• Sa., for a better tomorrow- V �SO` N": YvARR.14 g17 Gill ^ iast�e � gi�• �f`� PIPE SIZE AVERAGE O.D. NOM.I.D. MIN.T. MIN. E APPROX. D9 APPROX. Yj_ A�p� y �� (IN) (IN) (IN) (IN) (IN) (IN) WEIGHT T) V�� /�/��. *f ° PRESSURE CLASS 165 psi(DR 25) �'!'NA/TEED..... N 4 4.80 4.39 0.192 5.25 5.57 1.9 o 0 6 6.90 6.31 0.276 6.40 8.00 3.9 H 8 9.05 8.28 0.362 7.05 10.50 6.7 v� 10 11.10 10.16 0.444 8.20 12.88 10.1 0 12 13.20 12.08 0.528 8.80 15.31 14.4 2' w PRESSURE CLASS 235 psi (DR 18)* o p 4 4.80 4.23 0.267 5.25 5.87 2.6 2 tu 6 6.90 6.09 0.383 6.40 8.43 5.3 '‹ a 8 9.05 7.98 0.503 7.05 11.06 9.2 m 10 11.10 9.79 0.617 8.20 13.57 13.9 m CD 12 13.20 11.65 0.733 8.80 16.13 19.7 PRESSURE CLASS 305 psi (DR 14)` a c. 4 4.80 4.07 0.343 5.25 6.17 3.2 m 6 6.90 5.86 0.493 6.40 8.87 6.7 v 8 9.05 7.68 0.646 7.05 11.63 11.6 y Ch 10 11.10 9.42 0.793 8.20 14.27 17.6 m a 12 13.20 11.20 0.943 8.80 16.97 25.10 Consult JM Eagle'for CSA and other listing availability prior to shipment. a) Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. o o in f m 0 D9 I.D. : Inside Dameter O.D. :Outside Diameter 5 \\\\ \\\\ \\\\ \\\\ \\\\ \ \ \\\\ T. a)O D D. :Bell Outside Diameter T I.D. E ) E :Distance between Assembly Mark to the end of spigot. m Assembly Mark E. Product Standard: ANSI/AWWA C900 Certifications: ANSI/NSF Standard 61 Pipe Compound: ASTM D1784 Cells Class 12454 UL Standard 1285 = al Gasket: ASTM F477 Pipe Length:20 feet laying length s Integral Bell Joint: ASTM D3139 Installation: AWWA C605 • JM Eagle" Installation Guide SUBMITTAL INFORMATION ... r� . Restraint Series UFR1390-C-x-I for C900 PVC and , Ductile Iron Pipe SERIES 1390-C RESTRAINT DEVICE FOR C900 PVC AND DUCTILE IRON PIPE PIPE BELL JOINTS CAST SIZES 4" -12" 1300 SPLIT RESTRAINER I 1390 ASSEMBLY I 1300 UNIT(SPLIT RING) 1300 UNIT(SPLIT RING) 1! �AI RESTRAINER ESTRAINER 'I C } RESTRAINING ROD(D)&(E) BC MAX i ;Alrirp....7.14: ,L.�, I I.� i � B kr.l. I I i.;,11 '� �. I,SERRATIONS TO BC MIN B �� GRIP PIPE +II �jI / PIPE SPIGOT PIPE BELL CLAMPING BOLTS I (F)&(G) NOM PVC PIPE WITH RESTRAINING CLAMPING BOLTS PIPE DI PIPE OD B C Roos A BC MAX BC MIN /SUBMITTED SIZE STYLE 1390-C APPROX MAX NO. SIZE No. SIZE ITEMS OD CATALOG No. D E F G 4" 4.80 UFR1390-C-4-I , 1-1/8" 9-1/8" 12" 2 3/4"x 17" 4 5/8"x 3-1/2" 7.50" 7.14" 1 6" 6.90 UFR1390-C-6-I 1-1/8" 11-1/8" 13" 2 3/4"x 17" 4 5/8"x 3-1/2" 9.50" 9.14" 8" 9.05 UFR1390-C-8-I 1-1/4" 14-5/8" 15" 2 3/4"x 17" 4 3/4"x 4" 12.98" 11.36" 10" 11.10 UFR1390-C-10-I 1-3/8" 16-5/8" 16" 4 3/4"x 24" 4 7/8"x 5" 15.00" 13.50" 12" 13.20 UFR1390-C-12-I 1-3/8" 19-1/4" 18" 4 3/4"x 24" 4 7/8"x 5" 17.62" 15.62" FEATURES • 4" - 12" Sizes: Cast Ductile Iron per ASTM A536 Grade 65-45-12. • 360° contact and support of the pipe wall. • Restraining rods are high strength, low alloy steel per ANSI /AVWVA C111 /A21.11. • Rated at full rated pressure of any class of PVC Pipe, minimum 2:1 safety factor. • Ductile Iron Pipe shall have the following pressure ratings: 4" through 8" = 250 PSI 10" and 12" = 200 PSI. • Black E-coat epoxy-coated The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications,are subject to change without notice. Please verify that your product information is current. ThFe Ford Meter Box Company, Inc. Submitted By: Oc,..z P.O. Box 443, Wabash, Indiana U.S.A. 436992-0443 L. , E R D Phone: 260-563-3171 / Fax 800-826-3487 q'= Overseas Fax: 260-563-0167 http://www.fordmeterbox.corn 08/03/09 eat& ' TM — PRODUCT INFORMATION & SPECIFICATIONS — Detectable Marking Tape Christy's'"Detectable Marking Tape provides for easy buried pipeline detection and below ground identification and warning.The tape can be located below ground with a non-ferrous metal detector, when buried at the proper depths. Christy's"'Detectable Tape Must Be Adir Buried Flat For Maximum Detectability and Line Protection. We recommend bury depths of: ` " rammed l � 5'IrlgrtRux1 TAPE WIDTH 2" 3" 6° 12"or wider TAPE BURY DEPTH 6"-18" 6"-28" 6"-36" 6"-36" Detectable Marking Tape SPECIFICATIONS Tape consists of Minimum 4.5 MIL overall thickness, with 0.0035 MIL solid aluminium foil core. The warning mes- sage is"Buried, or Encased"to prevent ink rub-off and is impervious to acid, alkalis and other destructive elements found in soil. All Christy's tape meets or exceeds the industry standards including the America Public Works As- sociation (APWA)color code. TEST DATA VALUE MATERIAL IDENTIFICATION 3" &6"WIDE 4.5 MIL OVERALL FOIL THICKNESS 0035 MIL TEST PROCEDURE ASTM-D-8820, METHOD A 90% SPECIMEN CONDITIONS 73°F/50% R.H TEST TEMPERATURE 73°F ELONGATION 90% TENSILE STRENGTH TRANSVERSE 5530 PSI TENSILE STRENGTH LONGITUDINAL 4544 PSI ROLL WEIGHT 3"X 1000' +/ 7.5 LBS ROLL WEIGHT 6"X 1000' -V-15 LBS MINIMUM WEIGHT 10 LBS PER 1000' UNIT MAXIMUM IMPRINT LENGTH 36" COLOR CODE DESCRIPTION BLUE WATER&ASSOCIATED LINES BROWN FORCE MAINS&ASSOCIATED LINES GREEN SANITARY&ASSOCIATED LINES ORANGE TELECOMMUNICATIONS &TELEPHONE LINES PURPLE RECLAIMED WATER LINES RED ELECTRIC &ASSOCIATED LINES YELLOW GAS &ASSOCIATED LINES The tape is manufactured by T. Christy Enterprises, Inc. (800)258-4583. The model number is (TA-DT-XX-XXX). See model number designations on the following page. Subject to change without notice. May 2011. www.tchristy.com • (800) 258-4583 4 , TM eft rs — PRODUCT INFORMATION & SPECIFICATIONS - STANDARD COLOR/LEGEND COMBINATIONS How to Order Underground Marking Tapes TA.XX.XX.XXXXX Example: TA.DT.2.PRW is 2"Detectable Purple Reclaimed Water. T of T:.e w.. of Tape Colors Legend DT-Detectable ® b-blue CP-Cathodic Protection RAW-Raw Water 3-3" P-Purple E-Electric RJ-Restrained Joint 6-6" Y-Yellow F-Fire RW-Reclaimed Water 12-12" G-Green FM-Force main STDR-Storm Drain R-Red FO-Fiber Optic T-TPlrphnn W-White G-Gas W-Water 0-Orange I-Irrigation NPW-Non-Potable Water STANDARD COLOR/LEGEND COMBINATIONS Color Legend Text Blue BI "Caution Irrigation Line Buried Below" Blue BNPW "Caution Non-Potable Water Line Buried Below" Blue BPW "Caution Potable Water Line Buried Below" Blue BW "Caution Water Line Buried Below" Blue RJ "Caution Restrained Joint Buried Below" Brown BFM "Caution Force Main Buried Below" Green GFM "Caution Force Main Buried Below" Green GI "Caution Irrigation Line Buried Below" Green GNPW "Caution Non-Potable Line Buried Below" Green GPW "Caution Potable Line Buried Below" Green GRAW "Caution Raw Water Line Buried Below" m Green GS "Caution Sewer Line Buried Below" Green GSTDR "Caution Storm Drain Buried Below" Orange OFO "Caution Fiber Optic Line Buried Below" ti - Orange OT "Caution Telephone Line Buried Below" Orange OCP "Caution Cathodic Protection Cable Buried Below" 101...1011 Purple PRW "Caution Recycled/Reclaimed Water Line Buried Below" Purple PNPW "Caution Non-Potable Line Buried Below" Red RE "Caution Electric Line Buried Below" NOTE: Not all widths are Red RF "Caution Fire Line Buried Below" available as standard for Yellow YG "Caution Gas Line Buried Below" the stock color/legend combinations shown. Contact Christy's" SPECIAL AND CUSTOM LEGENDS for stock availability of Christy's"'offers a full range of non-standard legend/color combinations in addition to the specific products. Non- combinations listed below, including specialty applications such as Telemetry, Irrigation stock combinations are and additional water line wording.All standard combinations listed are available in at subject to minimum least one color/width combination.We offer specific agency legends,designations or requirements and plate color combinations. Custom legends can include the use of specific wording, insignias charges. and phone numbers. Call for special pricing. Subject to change without notice. May 2011 www.tchristy.com • (800) 258-4583 W ` HF-CCS PE30 (HIGH-FLEX / OPEN-TRENCH) Ce Tracer Wire • High-Flex Copper Clad Steel(HF-CCS)• 21%IACS Conductivity•Corrosion Resistant High-Density,High Molecular Weight Polyethylene(HMWPE-HDPE)Insulation• Moisture,Chemical,and Oil Resistant Impact,Crush,and Abrasion Resistant• RoHS Compliant• Direct Burial Rated•30 Volts• Made in the USA la C.) "PRO-TRACE HF-CCS -- FLEXIBILITY& STRENGTH -- IT'S THE FUTURE OF TRACER WIRE" Applications and Information I II • PRO-TRACE®HF-CCS PE30 is used for tracer wire applications not exceeding 30 Volts. Tracer wire is used to conductively locate buried utility lines for the gas,water,sewer, telecommunication,and electrical markets. • PRO-TRACE®HF-CCS PE30 is designed to embody the flexibility,memory,and feel of copper. It also has a 43%higher break-load,minimizing damage during installation and while in service. Equal to copper in signal tracing performance. It simply outperforms copper tracer wire. Designed for open-trench and plow-in installations using 1 wire. • Considerably lower in cost and great price stability compared to copper. • RoHS Compliant,made in the USA,and works with connectors you already use. (1) Cr) IX Cr) Standards and References ix PRO-TRACE®HF-CCS PE30 conductors meets or exceeds all applicable ASTM specifications, T LU and requirements of the National Electrical Code. O ® • ASTM B910/B190M: Standard Specification for Annealed Copper-Clad Steel Wire �M • ASTM B170: Standard Specification for Oxygen-Free Electrolytic Copper W a • ASTM D1248: Standard Specification for Polyethylene Plastics Extrusion Materials CIFor Wire and Cable V mA♦ Co) ' Construction 1' 02 Cr O PRO-TRACE®HF-CCS PE30 is a flexible,copper-clad steel tracer wire. A low carbon steel elcore,metallurgically bonded with a copper cladding,that is uniform and continuous,creating EL a bi-metal conductor that acts as one and is corrosion resistant.Special annealing processes T are performed during the cladding process giving HF-CCS the flexibility and feel of copper, i f THE but 43%higher in strength which means less breaks then copper tracer wire. O '? PRO-TRACE®HF-CCS PE30 uses a 30 mil,high-density,high molecular weight polyethylene W (HDPE)insulation. HDPE provides an excellent balance of surface smoothness,processing w ease and electrical consistency. HDPE provides superior strength against underground pR� elements that help prevent accidental breaks caused buy rocks in shifting soil conditions. aids Lim Specification Example CO Tracer wire for open-trench installation shall be a 12 AWG solid,PRO-TRACE®HF-CCS PE30. Conductor shall be soft-drawn, 21%IACS,copper clad steel,utilizing a AISI 10061ow carbon steel core(required to meet break load and flexibility),with /^•� breakload of 282 lbs(55,000 psi). Conductor shall be extruded with a 30 mil,high density,high molecular weight polyethylene li (HMW-HDPE)persuant to ASTM D1248 standard. Tracer wire shall be rated for direct burial use at 30 volts and RoHS compliant. Tracer wire shall be PRO-TRACE®HF-CCS PE30 as manufactured by Pro-Line Safety Products and made in the USA. Specification Updated: 9.26.2011 09:23:00 CST PRO-TR is a registered trademark of Pro-Line Safety Products Co. TABLE 1: CONDUCTOR (Physical, Mechanical and Electrical Properties) W 18 WG _.,°.16AW c:,• et ° Conductor Type HF-CCS HF-CCS HF-CCS HF-CCS HF-CCS HF-CCS Conductor Temper Annealed Annealed Annealed ' Annealed Annealed Annealed Steel Grade AISI 1006 AISI 1006 AISI 1006 AISI 1006 j AISI 1006 AISI 1006 Copper Grade UNS C10200 UNS C10200 UNS C10200 UNS C10200 UNS C10200 UNS C10200 at W V�Rated Break Load 70 lbs 111 lbs 177 lbs 282 lbs 448 lbs 713 lbs Rated Tensile Strength 55,000 psi 55,000 psi 55,000 psi 55,000 psi 55,000 psi 55,000 psi II‹ 20.0% 20.0% 20.0% 21.0% 21.0% 22.0% �y Nominal Copper Thickness(%of Diameter) 3.0% 3.0% 3.0% 3.0% 3.0% 3.0% CC Nominal Copper Weight(Per 1,000') 13.0% 13.0% 13.0% 13.0% 13.0% 13.0% Nominal DC Resistance 30.399 ohms 19.119 ohms 12.024 ohms 7.562 ohms 4.756 ohms 2.991 ohms TABLE 2: INSULATION (Physical, Mechanical and Electrical Properties) TEST DESCRIPTION ASTM STANDARD TYPICAL VALUES ,' Density @ 23°C ASTM D1505 0.945 g/cm' Melt Flow Rate ASTM D1238 0.70 g/10 min Tensile Strength ASTM D638 3,400 psi Tensile Strength Retention ASTM D638 90%after 48 hours @ 100°C Tensile Elongation ASTM D638 500% Tensile Elongation Retention ASTM D638 90%after 48 hours @ 100°C Environmental Stress Cracking ASTM D1693 0 failures @ 48 hours Thermal Stress Cracking ASTM D2951 0 failures @ 96 hours _,.. *, '�. Brittleness Temperature ASTM D746 -76°C Melting Temperature ASTM D3418 260°C :)" ' ° `,°, Oxidative Induction Time ASTM D3895 170 min @ 200°C Dielectric Constant ASTM D1531 2.32 @ 1 MHz Dissipation Factor ASTM D1531 0.00006 @ 1 MHz DC Volume Resistivity @ 23°C ASTM D257 >1 x 10's ohm-cm . " ••.,"• RATED' RA D-' - HOPE ' ' RODUCT PRODUCT s NOM 1,000 - STANDARD PART N0. DESCRIPTION BREAK TENSILE INSULATK)N LOAD STRENGTH THICKNESS O° SHIPPING '' PACKAGES EIGHT WEIGHT 1 CO WEIGHTS,MEASUREMENTS AND PACKAGING 74418XXXX 18 SOL HF-CCS PE30 70 lbs 55,000 psi 0.030" 0.101" 4.4191 7.14 500'/1000'/2500' 74416XXXX 16 SOL HF-CCS PE30 111 lbs 55,000 psi 0.030" 0.111" 7.0219 10.15 CUSTOM ORDER _ 74411XXXX 14 SOL HF-CCS PE30 177 lbs 55,000 psi 0.030" 0.124" 11.1800 14.82 5007 1000'/2500' i I 74412XXXX 12 SOL HF-CCS PE30 282 lbs 55,000 psi 0.030" 0.141" 17.7644 22.05 500',1000'/2500' IIJ 74413XXXX 10 SOL HF-CCS PE30 448 lbs 55,000 psi 0.030" 0.152" 28.2537 33.35 500'/1000'/2500' 74414XXXX 8 SOL HF-CCS PE30 713 lbs 55,000 psi 0.030" 0.189" 44.9297 51.05 CUSTOM ORDER , INSULATION COLOR & REEL LENGTH ',. •EEL & PACKAGING INFORMATION irs. •. .. .+�,` -- s i000'REEL Makall SIZE LENGTH MATERIAL REEL ARBOR PALLET 4 BLACK 0132 0141 0147 DIMENSION HOLE QUANTITY BLUE 0232 0241 0247 500 PLYWOOD(TREATED) 8"x 4" 1.5" 162,000 FT GREEN 0532 0541 0547 14 AWG 1000 PLYWOOD(TREATED) 8"x 9" 1.5" 180,000 FT WI ORANGE 0632 0641 0647 2500 PLYWOOD(TREATED) 12"x 6" 1.5" 180,000 FT , PURPLE 0832 0841 0847 500 PLYWOOD(TREATED) 8"x 6" 1.5" 126,000 FT RED 0932 0941 0947 12 AWG 1000 PLYWOOD(TREATED) 8"x 9" 1.5" 108,000 FT WHITE 1132 1141 1147 2500 PLYWOOD(TREATED) 12"x 9" 1.5" 120,000 FT YELLOW 1232 1241 1247 500 PLYWOOD(TREATED) 8"x 9" 1.5" 72,000 FT Ce """SOME PART NUMBERS MAYBE SUBJECT TO MINS"•" 10 AWG 1000 PLYWOOD(TREATED) 12"x 6" 1.5" 80,000 FT 2500 PLYWOOD(TREATED) 12"x 12" 1.5" 80,000 FT 500 PLYWOOD(TREATED) 8"x 9" 1.5" 54,000 FT CO 8 AWG 1000 PLYWOOD(TREATED) 12"x 9" 1.5" 48,000 FT let 2500 PLYWOOD(TREATED) 16"x 10" 1.5" 45,000 FT ,a•'" • J}41 T .4" OSpecification Updated: 9.26.2014 09:23:00 CST d'/hO-L//YE PRO-LINE SAFETY PRODUCTS COMPANY . SAFETY PRODUCTS 1099ATLANTICDRIVE,UNIT1 •• WEST DIVISION OFPRPPAK IND.INC, TOLL FREE: 800.554.3424 Zinc Coatings for Ductile Iron Fittings Revised 3/2018 TYLER UNIONS Quality Waterworks Products SUBMITTAL: ZINC COATED DUCTILE IRON FITTINGS (Current revisions for the noted Standards apply) Zinc coating forms a protective zinc oxide dielectric barrier.Zinc by-products,which are left behind after reacting in aggressive soils,form a healing protective barrier that cuts off further corrosion. Tyler Union Ductile Zinc Coated Fittings: • Zinc Coating applied per applicable requirements of ISO 8179 and ANSI/AWWA C104 • Applied Zinc coverage of 235 grams/meter'per ISO 8179-2:2017 • Zinc coated fittings shall be cement lined*as per ANSI/AWWA C104 • Has a finished layer of standard shop applied bituminous paint inside and out in accordance with ANSI/AWWA C104 • Zinc coated fittings will be stenciled with a blue"ZINC"for easy identification • V-Bio Enhanced Polyethylene Encasement is suggested in highly corrosive soils "Note:Contact your Tyler Union Sales Representative for special linings or top coats Fitting Sire Minimum AWWA *Double Cement Tyler Union Zinc Tvolcal Tyler Union Cement lining Thicknesl tinin Thickagn Coating Thickness 84,Thickness 2in.to 12in or 76 to 305mm. 1/16"or 1.6mm 1 8"or 3.2mm 3 mil 2—4 mil 14in.to 24in.or 356 to 610mm 3/32"or 2.4mm 3/16"or 4.8mm 3 mil 2-4 mil 30in.to 64in.or 762 to 1600mm 1/8"or 3.2mm 1/4"or 6.4mm 3 mil 2-4 mil 'NOTE:You must specify double cement lining upon order placement Bituminous Coating Top Coat 111 Zinc coating Stenciled"ZINC"for 1 ( Base layer easy identification 1 1 Bare Fitting . 1 • Ps diiipP___ Cement Lining& Bituminous Coating Anniston:(800)226-7601 Corona:(866)527-8471 Tyler:(800)527-8478 W ww.Iy I Brun ion.com -......., 23U - Mechanical Joint.41.511141.1 ANSI/AWWA C153/A21.53 TYLER UNION* Compact Ductile Iron Fittings Revised 4/2014 Quality Waterworks Products www tylcrunion.co n DOMESTIC PRODUCT SUBMITTAL Current Revisions Apply for all Listed Standards SIZES' 2"through*64"(2" not included in ANSI/AWWA C153)(*Contact Tyler Union for 54"-64"information) STANDARDS' ANSI/AWWA C153/A21.53, NFPA 13/24,3"-12" UL and 3-10"FM listed &approved(File-Tyler Union) Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability. PRESSURE RATING: *Flanged fittings rated at 250 psi. Mechanical joints 2"-24" rated at 350 psi and 30"-48"at 250 psi. *Note: With the use of rubber annular ring flange gasket,2"-24"fittings can be rated at 350 psi. Note: Wyes over 16"are not pressure rated. Contact Tyler Union for rating in your application. DEFLECTION' Max joint deflection 2"-12",5°and 14"-48",3°.Reduces by 50%at nominal pipe&fitting diameters NSF-61 &NSF-372• Meets all requirements including Annex G,Tyler Union's Underwriters Laboratory listing MH16439. ASPHALTIC COATING: Per ANSI/AWWA C104/A21.4 and ANSI/AWWA C153/A21.53. CEMENT LINING- Per ANSI/AWWA C104/A21.4,with double cement lining available upon request. EPDXY COATING' Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request. BARE' Available upon request FASTENERS' Per ANSI/AWWA C111/A21.11 and/or ASTM A242 high strength low alloy weathering steel INSTALLATION' Per AWWA C600 and C651 using pipe conforming to ANSI/AWWA C151/A21.51 or AWWA C900/905. 10.19 M.1 T umme Dom uuliuuVu��ll�rli�i' ii ; Pli 7 7 r. l,*/��rA if,IIF,r /f 1_ ANSI/AWWA/A C153/A21.53-Compact Flange ���`�•� • �: NominalThkMnessDimensionsinlnches(T=+/..060"j ��`1�_"_ � if Size T She T Size T II 0.12 n.-. A 075t N �«f 1 3 60 30 .75 18 .93 O P-1 4 .63 12 .81 20 .96 i e f 6 .63 14 .87 24 1.00 J o C F A x1 8 .70 16 .90 36 1.10 s�- Ille..on1o� MECHANICAL JOINT• NOMINAL JOINT DIMENSIONS IN INCHES BOLTS Size A Dia. B Hub C Dia. D Dia. F Dia. J Dia. K'Dia. K'Dia. L M S T X Size Qty. Inches DI Pipe Depth GLAND GLAND GLAND GLAND 2 2.51 2.50 3.50 3.60 2.61 4.75 6.19 6.89 0.58 0.62 0.36 0.30 3/4 5/8x3.0 2 3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 0.58 0.62 0.39 0.33 3/4 5/8x3.0 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 0.60 0.75 0.39 0.34 7/8 3/4x3.5 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 0.63 0.88 0.43 0.36 7/8 3/4x3.5 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 0.66 1.00 0.45 0.38 7/8 3/4x4.0 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 0.70 1.00 0.47 0.40 7/8 3/484.0 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 0.73 1.00 0.49 0.42 7/8 3/4x4.0 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 0.79 1.25 0.55 0.47 7/8 3/4x4.5 10 16 17.40 350 18.50 18.64 17.54 21.00 22.56 22.50 0.85 1.31 0.58 0.50 7/8 3/4x4.5 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 0.68 0.54 7/8 3/4x4.5 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 0.69 0.57 7/8 3/4x4.5 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1,02 1.56 0.75 0.61 7/8 3/4)(5.0 16 30 32.00 4.50 33.29 33.46 32.17 36.88 39.12 39.12 1.31 100 0.82 0.66 1-1/8 1x6.0 20 36 38.30 4.50 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 0.74 1-1/8 1x6.0 24 42 44.50 4.50 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.25 0.82 1-3/8 1-1/4x6.5 28 48 50.80 4.50 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 0.90 1-3/8 1-1/4x6.5 32 *Tyler Union Waterworks Contact Information* Tyler:11910 CR 492•Tyler,Texas 75706•(800)527-8478 Anniston:1501 W 17th St.•Anniston,AL 36201•(800)226-7601 Corona:1001 El Camino Ave.• Corona,CA 92879•(866)527-8471 61 28U - Flange Joint ANSI/AWWA C110/A21.10 TYLER UNION® Full Body Ductile Iron Fittings Quality Waterworks Products Revised 4.2013 www.tyterunbn.cam DOMESTIC PRODUCT SUBMITTAL Current Revisions Apply for all Listed Standards SIZES' 2"through*64"(*Contact Tyler Union for 54"-64"Flange fitting information) STANDARDS' ANSI/AWWA C110/A21.10, NFPA 13/24,3"-12" UL listed and approved(File-Tyler Union) Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability PRESSURE RATING: *2"through 48"flanged fittings rated at 250 psi. *Note: With the use of rubber annular ring flange gasket,2"-24"fittings can be rated at 350 psi DEFLECTION' Deflection is"not"recommended for flange joint fittings due to the rigidity of the joint upon completion of installation. NSF-61 &NSF-372• Meets all requirements including Annex G,Tyler Union's Underwriters Laboratory listing MH16439 COATING: Asphaltic or Primer per ANSI/AWWA C104/A21.4,Standard primer is Tnemec Pota Pox 140N-1211 Contact Tyler Union for additional coating options CEMENT LINING- Per ANSI/AWWA C104/A21.4,with double cement lining available upon request. EPDXY COATING- Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request. BARE' Available upon request FLANGES' ANSI Class 125 per ASME B16.1 and ANSI/AWWA C111/A21.11 Note: *ANSI Class 250 ASME B16.1 flanged fittings available upon request Note:*Due to larger bolt sizing and bolt circle, Class 250 flanges are"not"compatible with Class 125 flanged fittings. AWWA C110 and AWWA C115 Class 125 flanges are compatible. FLANGE THICKNESS:. ANSI/AWWA C115/A21.15 standard class 125 template for drilling bolt holes Note:Drilling templates are in multiples of 4,so that fittings may be made face to in any quarter. Bolt holes shall straddle the center line. FASTENERS' Per ANSI/AWWA C111/A21.11 and/or ASTM A242 high strength low alloy weathering steel INSTALLATION* Per AWWA C600 and C651 using pipe conforming to ANSI/AWWA C151/A21.51 -- FLANGE DETAILS IN INCHES BOLTS • 0 4 Size Diameter Flange Bolt Circle Flange Bolt Hole Size Qty. Inches DI Pipe O.D. Diameter Thickness"T" Diameter O j•�<(' 0 B.C. 3 3.96 7.50 6.00 0.75 0.750 5/8 x 2.25 4 O O 4 4.80 9.00 7.50 0.94 0.750 5/8 x 3.00 8 O Q } 6 6.90 11.00 9.50 1.00 0.875 3/4 x 3.50 8 8 9.05 13.50 11.75 1.12 0.875 3/4 x 3.50 8 10 11.10 16.00 14.25 1.19 1.000 7/8 x 4.00 12 12 13.20 19.00 17.00 1.25 1.000 7/8 x 4.00 12 1 14 15.30 21.00 18.75 1.38 1.125 1 x 4.50 12 16 17.40 23.50 21.25 1.44 1.125 1 x 4.50 16 ~ O'D" • 18 19.50 25.00 22.75 1.56 1.250 1-1/8x5.00 16 20 21.60 27.50 25.00 1.69 1.250 3-1/8x5.00 20 24 25.80 3200 29.50 1.88 1.375 1-1/4 x 5.50 20 T 30 32.00 38.75 36.00 2.12 1.375 1-1/4 x 5.50 28 38 38.30 46.00 42.75 2.38 1.625 1-1/2 x 7.00 32 T 42 4450 53.00 49.50 2.62 1.625 1-1/2x7.50 36 48 50.80 59.50 56.00 2.75 1.625 1-1/2 x 8.00 44 *Tyler Union Waterworks Contact Information* Tyler:11910 CR 492•Tyler,Texas 75706•(800)527-8478 Anniston:1501 W 17th St.•Anniston,AL 36201•(800)226-7601 Corona:1001 El Camino Ave.• Corona,CA 92879•(866)527-8471 67 The original, and the definitive standard. 2" THROUGH 12" MODEL 2639/2640 11> •wnoVED AWWA C509 250 PSI • UL/FM Approved 200 PSI • NSF 61 Certified Full Water Way • Fusion Bond Epoxy Coated • 10 Year Limited Warranty CLCW M VALVE CO. Clow Valve is a division o{MCWane,Inc. For Generations www.clowvalve.com I . E I E In 1975,Clow recognized the increased requirements and Clow was the first to introduce,and still leads in the design escalating maintenance cost of water systems in the and technical development,of the bubble-tight resilient United States. seating valve. Clow responded by introducing the first RAN(Resilient The Clow Resilient Wedge Valve,with its unique features and Wedge)Valve in America.This introduction revolutionized benefits,were the first to be manufactured with both AWWA the valve market in the U.S. and UL/FM approval for all water system requirements. A. -1 IL E L4-1 fill ell Li1 I S! : ir: �tM III I II A Imo-D n F-6100 F-6102 F-6103 F-6106 MECHANICAL JOINT FLANGED THREADED ENDS FLANGED X MJ 2"-12" 2"-12" 2"-3" 3"-12" P:=1 x x iiiiT [ to iii .. if i 1,111111 II. I�' I,�� I n e u 4 o—.I F-6110 F-6111 F-6112 F-6113 PUSH ON FOR MECHANICAL TYTON ENDS FOR DUCTILE FLANGED X TYTON SDR PVC CUTTING IN JOINT IRON AND C900 PVC PIPE 4"-12" 2"-12" 4•"-12" 4"-12" ¶: E -11 1 �1 61 flkill$ " M NOTE: It is recommended that valves be il 1I III ' I installed with stems vertical when 1111 used in raw sewage or sludge HD v 1,1.1 '1* A applications or in water with excessive sediment Flanged end F-6114 F-6120 F-6136 connections not recommended MECHANICAL JOINT MECHANICAL JOINT FLANGED OS&Y for buried service. FOR TAPPING POST INDICATOR VALVE CONSTRUCTION 3"-12" 2"-12'" 2"-12" NO.OF TURNS VALVE SIZE A B C D E G H P O R S U V TO FULL OPEN 2" 7 3-1/4 - 5-3/8 10-7/8 - - 3 10 12 7-1/4 - - 6-1/2 2-1/2". 7-1/2 - - 7-1/B 11-3/8 - - 3-1/4 16-3/8 13-7/8 7-1/4 - - 8 3" B 3-1/2 - 7-1/8 12-3/8 - 5-3/4 3-1/2 18-7/8 15-5/3 10 5-3/4 8-1/4 ID 4" 9 4-1/2 6-3/4 - 14-3/4 4-5/8 6-3/4 4-1/2 22-3/4 18-1/4 10 6-3/4 9-1/4 13-1/2 6" 10-1/2 5-1/2 7-7/8 - 19 5-1/4 8 5 30-1/6 23-3/4 12 8 10-1/2 19-1/2 8" 11-1/2 8-1/8 6-1/2 - 22-1/2 5-5/8 9-3/4 5-1/2 37-3/4 29-1/4 14 10-3/4 13-1/4 25-1/2 10" 13 10-1/2 10 - 26-1/2 7 11-3/4 7 45-3/4 35-3/8 18 12-1/2 14-7/8 31-1/2 12" 14 10-3/4 11-1/4 - 30 8-1/2 12 8-1/2 53-1/8 40-5/8 18 12-1/2 15 37-3/4 www.clowvalve.com q flMery. i A �o • AO 'L,MIIj COMMITTED TO ENVIRONMENTAL RESPONSIBILITY CLOW VALVE COMPANY IS COMMITTED TO PROTECTING OUR NATURAL RESOURCES THROUGH ENVIRONMENTALLY RESPONSIBLE MANUFACTURING PRACTICES,INCLUDING THE USE OF B0+%RECYCLED CONTENT IN OUR HYDRANTS AND VALVES. To learn more about our commitment to the environment,call 800-829-2569. RECOMMENDED SPECIFICATIONS 1. Valves shall conform to the latest revision of 7. All stems shall have two 0-rings located above AWWA Standard C509 covering resilient seated thrust collar and one 0-ring below.Stem 0-rings gate valves for water supply service. shall be replaceable with valve fully opened and subjected to full pressure.The stems on 2"—12" 2. The valves shall have an iron body,bonnet, shall also have a low torque thrust bearing located and 0-ring plate.The wedge shall be totally above and below the stem collar to reduce friction encapsulated with rubber. during operation. 3. The sealing rubber shall be permanently bonded 8. Waterway shall be smooth,unobstructed and free to the wedge per ASTM D429. of all pockets,cavities and depressions in the seat area.Valves 2"and larger shall accept a full size 4. Valves shall be supplied with 0-ring seals at all tapping cutter. pressure retaining joints. No flat gaskets shall be allowed. 9. The body,bonnet and 0-ring plate shall be fusion-bonded epoxy coated,both interior and 5. The valves shall be either non-rising stem or rising exterior on body and bonnet.Epoxy shall be stem,opening by turning left or right,and provided applied in accordance with AWWA C550 and with 2" square operating nut or a handwheel with be NSF 61 Certified. the word"Open"and an arrow to indicate the direction to open. 10. Each valve shall have maker's name,pressure rating,and year in which it was manufactured 6. Stems shall be cast copper alloy with integral cast in the body.Prior to shipment from the collars in full compliance with AWWA.All factory,each valve shall be tested by hydrostatic stems shall operate with copper alloy stem nuts pressure equal to the requirements of AWWA independent of wedge and of stem(in NRS valves). C509(and UL/FM where applicable). 11. Valves shall have all component parts cast and assembled in the USA and shall be manufactured by the Clow Valve Company. ISO 9001 www.clowvalve.com CL WW Wn--)VALVE CO. 902 South 2nd Street • Oskaloosa, Iowa 52577 For Generations PHONE 641-673-8611 FAX 641-673-8269 Clow Vale is a division of MCWane,Inc. SERIES 2000PV EBinktir,„ IROBMechanical Joint Restraint Your Connection to the Future" F O T PVC Pipe Features and Application: • Sizes 3 inch through 36 inch — Sizes 42 inch and 48 inch $'° Accommodated by Series 2200 _ u • MEGA-BONDTM Restraint Coating System For more information on MEGA-BOND, refer to www.ebaa.com/products/mega-bond z • Constructed of ASTM, + . 1 ' 65-45-12 Ductile Iron. ^^ - -- • The Mechanical Joint follower "' 1s 1..•. t1 f r gland is incorporated into the restraint. • Heavy Duty thick wall design • Support Products Available: •Split MJ repair style available for 3 inch through 12 inch. EBAA Series 2000SV Series 2012Pf/ for 12"Mechanical Joint Pipe or Fittings • Solid restraint harness available for C905 PVC pipe bells. EBAA Series 2800 • Split restraint harness available for C900 and C905 pipe bells and Nominal Series Shipping PVC fittings. Pit Size Number INei'hts EBAA Series 1500,1600 and 2500 3 2003 7.0 1 4 2004 8.8 • All 2000PV and related restraint 2006 12.1 ! products can be furnished as 6 8 2008 1E6 packaged accessories complete 26.0 12 2012 31.4 with appropriate restraint,gasket, 14 2014 47.6 lubrication and bolting hardware. 16 2016 52.8 18 2018 61.8 • For use on water or wastewater 20 2020 70.9 pipelines subject to hydrostatic 24 2024 828 pressure and tested in accordance 30 2030 128,5 36 2036 161.3 with either AWWA C600 or Note:For applications or pressures other than the one,show r;, ASTM D2774. please cant-art EBAA for assistance. U.S. Patent No. 4627774, 4896903, 5071175. 0605-5-H Copyright 2003©EBAA IRON,Inc. Mechanical Joint Restraint Sample Specification (The text of the specifications below can be copied and pasted from www.ebaa.com/download/2000spec.doc) Restraint devices for mechanical joint fittings and appurtenances conforming to either ANSI/AWWA C111/A21.11 or ANSI/AWWA C153/A21.53,shall conform to the following: Design Approvals Restraint devices for nominal pipe All physical and chemical test results Mechanical Joint Restraints shall be sizes 3 inch through 36 inch shall shall be recorded such that they can Listed by Underwriters Laboratories in consist of multiple gripping wedges be accessed via the identification the 4 inch through 12 inch sizes. incorporated into a follower gland number on the casting. These Mechanical Joint Restraints shall be meeting the applicable requirements Material Traceability Records(MTR's) Factory Mutual Approved in the 4 inch of ANSI/AWWA C111/A21.11. are to be made available, in hard copy, through 12 inch sizes. The devices shall have a working to the purchaser that requests such documentation and submits his gland Mechanical Joint Restraints,4 inch pressure rating equal to that of the through 24 inch pipe on which it is used. Ratings are body identification number. g shall meet or exceed the requirements of ASTM F1674 of for water pressure and must include a Production pieces that are too small to the latest revision. minimum safety factor of 2:1 in all accommodate individual numbering, sizes. such as fasteners and wedges,shall Mechanical joint restraint shall be Material be controlled in segregate inventory Series 2000PV produced by EBAA Iron until such time as all quality control Inc.or approved equal. Gland body,wedges and wedge tests are passed. These component MEGA-BONDT"" Restraint Coating System actuating components shall be cast parts may then be released to a from grade 65-45-12 ductile iron general inventory for final assembly All wedge assemblies and related parts material in accordance with ASTM and packaging. All components shall shall be processed through a phosphate A536. be manufactured and assembled in wash,rinse and drying operation prior to the United States. The purchaser coating application.The coating shall Three(3)test bars shall be shall,with reasonable notice,have the consist of a minimum of two coats of incrementally poured per production liquid Xylan®fluoropolymer coating with shift as per Underwriter's Laboratoryright to plant visitation at his/her expense. heat cure to follow each coat. (U.L.)specifications and ASTM A536. All casting bodies shall be surface Testing for tensile,yield and elongation Installation pretreated with a phosphate wash, rinse shall be done in accordance with Mechanical joint restraint shall require and sealer before drying.The coating ASTM ES. Chemical and nodularity conventional tools and installation shall be electrostatically applied and tests shall be performed as procedures per AWWA C600,while heat cured.The coating shall be a recommended by the Ductile Iron retaining full mechanical joint polyester based powder to provide Society,on a per ladle basis. deflection during assembly as well as corrosion,impact and UV resistance. Traceability allowing joint deflection after assembly. The coating system shall be MEGA- An identification number consisting of BOND by EBAA Iron, Inc.or approved year,day, plant and shift Proper actuation of the gripping equal. Requests for approved equal (YYDDD)(plant designation)(Shift wedges shall be ensured with torque must submit coating material and number),shall be cast into each gland limiting twist off nuts. process details for review prior to bid. body. For more information regarding MEGA-BOND,refer to the MEGA-BOND brochure or visit www.ebaa.com. Support Products for more information concerning these products please consult the catalog or www.ebaa.com - ..1: -: Series 2200 Series 2500 MEGALUG Restraint for Restraint for C900 and C905 : ' 471 /r / C905 PVC Pipe at PVC pipe at PVC fittings : I.. 'fl Mechanical Joint Fittings (Now Available in Sizes �` ' , , ,- (Sizes 42 and 48 inches) 42 and 48 inch), 4!-. - 1 . 4 Series 2800 , ,, Bell Restraint Harness ; .' ,, for C905 PVC Pipe Series 2000SV I ,�h0R i�►"""'' (Now Available in Sizes Split 2000PV Restraint ..., 4, ,..m,,,,,,a 42 and 48 inch) L—� for Existing Mechanical Joints .. Series 2000PV Submittal Reference Drawing A 1111 Allififtii% M-I I- D Iva %'`�A li �SPACERe AA $ H ) C K2 J F C Any Uii P n it* 0.125-- 1 0.125-1 C F Li S c� �1_ii- � ( A 121 SECTION A-A SECTION B-B CDF M P P R 1 K2 Wedge Bolt Weight Nominal Series (with Qty Qty IBS Pile Size Number nuts Off 3 2003 4.84 1.55 3.60 0.50 9.8 8,6 3/4 6.19 7.69 4 4 7.0 4 2004 5.92 1.68 4.90 0,50 10.5 9.5 7/8 7.50 9.13 4 4 8.8 6 2006 8.02 1.68 7.00 0.50 13.0 12,1 7/8 9.50 11.13 6 6 12.1 8 2008 10.17 1.68 9,15 0.62 14.5 13.6 7/8 11,75 13,38 6 6 16.3 10 2010 12.22 2,10 11.20 0.62 17,0 16,0 7/8 14,00 15.63 8 8 26.0 12 2012 14,32 2.10 13.30 0,75 19,0 18,1 7/8 16.25 17,88 8 8 31.4 14 2014 16,40 2,25 15.49 0,88 21,7 20,9 7/8 18,75 20.38 10 10 47,6 16 2016 18,50 2,25 17.58 0.88 23.8 23,0 7/8 2L00 22.63 12 12 52.8 18 2018 20.60 2,25 19,68 L13 25.9 25,1 7/8 23.25 24.88 12 12 61.8 20 2020 22,70 2.25 21.79 1.25 28.0 27.2 7/8 25,50 27.13 14 14 70.9 24 2024 26.90 2.75 25,99 1.42 32.3 31.5 7/8 30.00 31.63 16 16 92.9 30 2030 33.29 2.70 32,22 1.50 38,5 37.7 11/8 36.88 39,12 20 20 128.5 36 2036 39.59 2,70 38.52 1.50 44.8 44.0 11/8 43,75 46.00 24 24 161.3 Pressure Ratings Note:Dimensions are In inches and are subject to change without notice, Nominal Ratings for Ordinary Ratings for Peak Pressures used in Sewage Force Mains Series WaterWorksw/iransientSurgesOnly and Other Installations Designed for Cyclic Surges of1•Mi11.Cycles C905 PVC Pipe Pipe Size Number DR•14 DR•18 DR.25 SDR•17 SDR-21 SDR•26 DR•14 DR•18 DR•25 SDR•17 SDR•21 SDR•26 DR•18 DR•25 DR•32,5 3 2003 200 150 100 250 200 160 200 150 100 200 160 120 • 4 2004 200 150 100 250 200 160 200 150 100 200 160 120 • 6 2006 200 150 100 250 200 160 200 150 100 200 160 120 • 8 2008 200 150 100 -250 200 160 200 150 100 200 160 120 • 10 2010 200 150 100 250 200 160 200 150 100 200 160 120 • 12 2012 200 150 100 250 200 160 200 150 100 200 160 120 • 14 2014 235 165 • 16 2016 235 165 • 18 2018 - 235 165 • 20 2020 - - 235 165 • 24 2024 235 165 • 30 2030 - • 165 • 36 2036 - 125 Note:For applications or pressures other than those shown,please contact EBAA for assistance, ' E B EBRI MEGALUG • • IR :.� SERIES 1100 Your Connection to the FutureTM Mechanical Joint Restraint For Ductile Iron Pipe Features and Application: • Sizes 3"through 48" - : ` ` `' '- �� •• Constructed of ASTM A536 Ductile Iron A. - • Torque limiting Twist-Off Nuts .T/ 4101P. • MEGA-BONDTM' Restraint Coating System 441111 r 2 :� '_ a e, , ro ' - For more information on MEGA-BOND, refer o . to www.ebaa.com/products/mega-bond + • The Mechanical Joint follower ° gland is incorporated into the restraint. !."..;-'a 4* ♦ - • Heavy Duty thick wall design „ `, ,I, %s't ;,' n' • Support Products Available: •Split repair style available 3 inch through 48 inch. : '- EBAA Series 1100SD • Solid restraint harness available for push-on pipe bells. ' EBAA Series 1700 Series 1112, for 12"Mechanical Joint Restraint of Pipe or Fittings. • Split restraint harness available for existing push-on bells EBAA Series 1100HD • All MEGALUG and related restraint Nominal Series Shipping Deflection Pressure Rating products can be furnished as Pi'eSite Number INei:hts De:rees (Ps0 packaged accessories complete 3 1103 6.1 3° 350 with appropriate restraint,gasket, 4 1104 7.7 3° 350 lubrication and bolting hardware. 11.1 0 350 • For use on water or wastewater 10 1110 23,9 3° 350 pipelines subject to hydrostatic 12 1112 312 3° 350 pressure and tested in accordance 14 1114 48.5 2° 350 with either AWWA C600 or 16 1116 56.4 2° 350 ASTM D2774. 18 1118 63.1 Ph° 250 Megalug wedge im.ression on ductile iron pipe. 20 1120 72.3 1Ih° 250 24 1124 133,1 1'h° 250 30 1130 194.6 1° 250 36 1136 234.0 1° 250 42 1142 536.0 1° 250 48 1148 653,0 1° 250 • .,* as i1 j! Note:For applicationsor pressuresotherthan those shown,please contact EBAA for assistance. 'II,' �. iiiiimmlimgiiiiMiNINMIIIIIIMIIIIM Made In ft) U.S. Patent No. 4092036, s' <'rr The U S A 4627774, 4779900, 4896903, 5544922 0306-5-E Copyright 2006©EBAA IRON,Inc. Mechanical Joint Restraint Sample Specification (The text of the specifications below can be copied and pasted from www.ebaa.com/download/1100Spec.DOC) Restraint devices for mechanical joint fittings and appurtenances on Ductile Iron Pipe conforming to either ANSI/AWWA C111/A21.11 or ANSI/AWWA C153/A21.53,shall conform to the following: Design Traceability Approvals Restraint devices for nominal pipe sizes An identification number consisting of Restraint devices shall be Listed by 3 inch through 48 inch shall consist of year,day, plant and shift(YYDDD)(plant Underwriters Laboratories(3"through 24" multiple gripping wedges incorporated designation)(Shift number),shall be inch size)and Approved by Factory into a follower gland meeting the cast into each gland body. Mutual(3"through 12"inch size). applicable requirements of ANSI/AWWA All physical and chemical test results Mechanical joint restraint for ductile Iron C110/A21.10. shall be recorded such that they can be pipe shall be Megalug Series 1100 The devices shall have a working accessed via the identification number produced by EBAA Iron Inc.or approved pressure rating of 350 psi for 3-16 inch on the casting. These Material equal. and 250 psi for 18-48 inch. Ratings are Traceability Records(MTR's)are to be for water pressure and must include a made available, in hard copy,to the MEGA-BONDTM Restraint Coating System minimum safety factor of 2 to 1 in all purchaser that requests such All wedge assemblies and related parts sizes. documentation and submits his gland shall be processed through a phosphate body identification number. wash,rinse and drying operation prior to Material coating application.The coating shall Production pieces that are too small to Gland body,wedges and wedge consist of a minimum of two coats of accommodate individual numbering, actuating components shall be cast from such as fasteners and wedges,shall be liquid Xylan®fluoropolymer coating with grade 65-45-12 ductile iron material in controlled in segregate inventory until heat cure to follow each coat. accordance with ASTM A536. All casting bodies shall be surface such time as all quality control tests are For applications requiring restraint 30 pretreated with a phosphate wash, rinse passed. These component parts may inch and greater, an alternate grade of and sealer before drying.The coating then be released to a general inventory iron meeting the material requirements shall be electrostatically applied and heat for final assembly and packaging. of ASTM A536 is acceptable, providing cured.The coating shall be a polyester the device meets all end product All components shall be manufactured based powder to provide corrosion, performance requirements. and assembled in the United States. impact and UV resistance. The purchaser shall,with reasonable Ductile iron gripping wedges shall be notice, have the right to plant visitation The coating system shall be MEGA-BOND heat treated within a range of 370 to by EBAA Iron, Inc.or approved equal. at his/her expense. 470 BHN. Requests for approved equal must submit Three(3)test bars shall be Installation coating material and process details for incrementally poured per production Mechanical joint restraint shall require review prior to bid. shift as per Underwriter's Laboratory conventional tools and installation (U.L.)specifications and ASTM A536. procedures per AWWA C600,while For more information regarding MEGA- Testing for tensile,yield and elongation retaining full mechanical joint deflection BOND, refer to the MEGA-BOND brochure shall be done in accordance with ASTM during assembly as well as allowing joint or visit www.ebaa.com. E8 deflection after assembly. Chemical and nodularity tests shall be Proper actuation of the gripping wedges performed as recommended by the shall be ensured with torque limiting Ductile Iron Society,on a per ladle basis. twist off nuts. Support Products for more information concerning these products please consult the catalog or www.ebaa.com fh,1, Series 1100SD a Split MEGALUG Restraint �'‘ Series 1700 for Existing Mechanical Joints l MEGALUG Restraint for Push-On Bells Series 1100SDB it. Split MEGALUG Restraint ' a" 404 n Series 1100HD o for Mid Span Applications Split MEGALUG Restraint for Existing Push-On Bells Series 1100 Submittal Reference Drawing .1/4A M _--_ D - �� � -- 0.75 _ -0.75 m ( E I' a 1 ...- . B eA M'A 4 0r p nCJ&IK2 IIR �` 1 J J 0.125-4 0.125�� C uo FC F N ,�� P ` ! 11 11 A4\-. 1 I a B �J SECTION A-A SECTION B-B I C D F M P X 1 K2 Wedge Bolt Weight Press Series (with NominalPly Qty LBS Ratings PiieSize Number nuts Off 3 1103 4,48 2,27 4.06 0.62 9.06 0.750 6.19 7.69 2 4 6.1 350 1104 5.92 2.27 4.90 0.75 9.90 0.875 750 9.12 2 4 7.6 350 6 1106_ 8.02 2.27 7.00 0.88 12.00 0.875 9.50 r 11.12 3 6 11.8 350 B 1108 10017 2,31 915 1.00 14.15 0.575 11J5 13.37 4 6 14.9 -„,_3 10 1110 12.22 2.37 11.20 1,00 16.20 0.875 14.00 15.62 6 8 23.9 350 12 1112 14,32 2,37 13,30 1,25 18.30 0,875 16.25 17,88 8 8 31.2 350 14 1114 16.40 2,69 15.44 1.50 20.94 0,875 18.75 20.25 10 10 49.7 350 16 1116 18.50 2.69 17.54 1,56 22,90 0.875 21.00 22.50 12 12 56,4 350 18 1118 20,60 2.69 19.64 1.63 25.00 0.875 23.25 24,75 12 12 63.6 250 20 1120 22.70 2.69 21.74 1.69 27,10 0.875 25.50 27.00 14 14 71.0 250 24 1124 26.90 3.20 25.94 1.81 32.64 0.875 30.00 31.50 16 16 128.7 250 30 1130 33.29 3.20 32.17 2.25 38.87 1.125 36.88 39.12 20 20 190.7 250 36 1136 39.59 3.20 38.47 2.25 45.17 1.125 43.75 46.00 24 24 226.5 250 42 1142 45.79 4,56 44,67 3.88 55.57 1,375 50.62 53.48 28 28 518.9 250 48 1148 52.09 4.56 50.97 3.88 61.87 1.375 57.50 60.36 32 32 608.3 250 Note: Dimensions are in inches and are subject to chan:e without notice. Important Notes • The 1100 Series should not be used on plain end • EBAA Seal Gaskets are provided with the 30"through fittings. 48" MEGALUG restraints.These are required on the • For test pressures above the rated pressures shown, above referenced sizes to accommodate the pressure contact EBAA for recommendations,such as tandem ratings and safety factors shown. restraint for high pressure applications. • Extra length T-bolts are provided with the 42"and 48" • If you experience the need to install the 1100 Series in sizes to facilitate easier assembly of the mechanical an unconventional manner please consult our joint. engineering department. • All MEGALUG components are made of ductile iron.The • The 1100 Series is intended for use on ductile iron wedges are heat treated to a hardness range of 370 to pipe.The restraint can be used on grey iron pipe if the 470 BHN. pipe is not severely corroded and is in sound condition • LISTINGS AND APPROVALS Sizes 3"through 24"are and has an outside diameter that can be listed by Underwriters Laboratories,Inc.Category HJKF accommodated. For more information on the use of the "Fittings, Retainer Type,"with a deflection angle of 5 MEGALUG restraint on grey iron pipe ask for degrees(3"through 12")and 2-1/2 degrees(14" Connections Bulletin DI-1. through 24".)The listing file number is EX2836.Sizes 3"through 12"are Factory Mutual approved. Custom Pipe & Coupling 10560 Fern Avenue Stanton, Ca 90680 Phone 714-761-8801 Fax 714-761-3417 To: HD Supply Waterworks Re: Submittal Information This will certify that all Ductile Iron pipe spools fabricated by Custom Pipe and Coupling are made to conform to, ANSI/AWWA C115/A21 .15, C151/A21 .51 , C606 standards. Custom Pipe and Coupling is a member of the National Association of Pipe Fabricators. Custom Pipe and Coupling fabricates all spools in Stanton, California. Sincerely, Michael T. Litty Sales Manager Custom Pipe and Coupling Material used in accordance with AWWA & ANSI Standards Pipe AWWA/ANSI C151 / A21 .51 Flanged AWWA/ANSI C115 / A21 .15 Grooved AWWA/ANSI C606 Lining AWWA/ANSI C104 Coating AWWA/ANSI C104 PRODUCT DATA SHEET TNE�t b.c TNEME-ZINC SERIES 90-97 PRODUCT PROFILE L. GENERIC DESQIPNON Aromatic Urethane,Zinc-Rich COMMON USAGE An advanced technology,two-component,moisture-cured,zinc-rich primer providing extraordinary performance.It's user friendly and rapid curing so chemical-and corrosion-resistant topcoats can be applied the"same-day."Also used for field touch-up of inorganic zinc coating.Application methods include"dry-fall"under certain conditions(see Application). COLORS 90-97 Reddish-gray ZINC PIGMENT 83%by weight in dried film SPECIAL QUALIFICATIONS Series 90-97 meets AISC requirements of Class B surface with a mean slip coefficient no less than 0.50 and a tension creep not in excess of.005 inches(.13mm). Tneme-Zinc uses a zinc pigment which meets the requirements of ASTM D 520 Type ID and contains less than.002% lead.This level qualifies it to be classed as"non-lead"(less than 0.009%lead by weight)as defined in 16 CFR Part 1303 of the Consumer Product Safety Commission regulations.Conforms to SSPC Paint 20,Type II. PERFORMANCE aim Extensive test data available.Contact your Tnemec representative for specific test results. COATING SYSTEM TOP(QA1S Series 1,6,27,27WB,46H-413,66,L69,L69F,N69,N69F,V69,V69F,73,104,113,114,115, 135,161,394,1028, 1029, 1074, 1074U,1075,1075U Note:Certain topcoat colors may not provide one-coat hiding depending on method of application.Contact your Tnemec representative.Note:Series 90-97 must be exterior exposed for three days prior to topcoating with Series 1028 or 1029. Note:Series 90-97 must be exterior exposed for one day prior to topcoating with Series 27WB. • SURFACE PREPARATION Severe Exposure:SSPC-SP1O/NACE 2 Near-White Blast Cleaning with a minimum angular anchor profile of 1.5 mils, Moderate Exposure:SSPC-SP6/NACE 3 Commercial Blast Cleaning with a minimum angular anchor profile of 1.5 mils. TECHNICAL DATA YOWMESOUDS 63.0 t 2.0%(mixed) RECOMMENDED DFT 2.5 to 3.5 mils(65 to 90 microns)per coat. CURING lIME Without 44-710 Temperature t To Handle To Recoat 75°F(24°C) 1 hour 4 hours 65°F(18°C) 1 1/2 hours 5 hours 55°F(13°C) 2 hours 6 hours 45°F(7°C) 2 1/2 hours 7 hours 35°F(2°C) 3 hours B hours t 50%relative humidity.Curing time will vary with surface temperature,humidity and film thickness. Note:For faster curing,low humidity and low-temperature applications,add No.44-710 Urethane Accelerator(see separate product data sheet). VOLATILE ORGANIC COMPOUNDS Unthinned:2.68 lbs/gallon(321 grams/litre) Thinned 2.5%(No.2 or No.3 Thinner):2.79 lbs/gallon(334 grams/litre) Thinned 10%(No.2 or No.3 Thinner):3.10 lbs/gallon(371 grams/litre) HAPS Unthinned:5.12 lbs/gal solids Thinned 2.5%:5.41 lbs/gal solids(No.2 Thinner);5.13 lbs/gal solids(No.3 Thinner) Thinned 10%:6.27 lbs/gal solids(No.2 Thinner);5.16 lbs/gal solids(No.3 Thinner) THEORETICAL COVERAGE 1,011 mil sq ft/gal(24.8 mt/L at 25 microns).See APPLICATION for coverage rates. NUMBER OF COMPONENTS Two:Part A and Part B PAQAGING Four-Gallon and One-Gallon Kits:Consist of one premeasured container of liquid(Part A)and one premeasured container of powder(Part B).When mixed,yields four gallons(15.1L)or one gallon(3.79L). NET WEIGHT PER GALLON 23.94±0.60 lbs(10.86±.27 kg) STORAGETFMPERATURE Minimum 20°F(-7°C) Maximum 110°F(43°C) TDAPERAATIIRE RESISTANCE Dry(Continuous)250°F(121°C) Intermittent 300°F(149°C) SHELF LIFE Part A:12 months at recommended storage temperature. Part B:24 months at recommended storage temperature. RASH POINT•SETA Part A:78°F(26°C) Part B:N/A HEARTH&SARI( Paint products contain chemical ingredients which are considered hazardous.Read container label roaming and Material Safety Data Sheet for important health and safety information prior to the use of this product. Keep out of the reach of children. ©August 5,2015 b Tnemec Company Inc. Published technical data and instructions are subject to change without notice.The online catalog at Page 1 of 2 U Y P Y www.memec.com should be referenced for the most current technical data and instructions or you may contact B your Tnemec representative for current technical data and instructions. TNEME-ZINC I SERIES 90-97 COVERAGE RATES Dry Mils(Microns) Wet Mils(Microns) Sq Ft/Gal(ma/Gal) Suggested 3.0(75) 5.0(125) 337(31.3) Minimum 2.5(65) 4.0(100) 404(37.5) Maximum 3.5(90) 5.5(140) 289(26.9) Allow for overspray and surface irregularities.Film thickness is rounded to the nearest 0.5 mil or 5 microns.Application of coating below minimum or above maximum recommended dry film thicknesses may adversely affect coating performance. 6 Always use the entire contents of A and B components.Use an air-driven power mixer and keep material under constant agitation while mixing.Slowly sift powder(Part B)into liquid(Part A). -Do Not Reverse This Procedure-Adjust mixer speed to break up lumps and mix until the two components are thoroughly blended.Strain through a 35 to 50 mesh(300 to 600 microns)screen before using.For spray application,keep under low RPM agitation to prevent settling.For brush or roller application,stir frequently to prevent settling.Do not use mixed material beyond pot life limits. INIINDN6 For spray,thin up to 10%or 3/4 pint(380 mL)per gallon with No.2 Thinner if temperatures are below 80°F(27°C).Thin up to 10%or 3/4 pint(380 mL)per gallon with No.3 Thinner if temperatures are above 80°F(27°C).For brush or roller, thin up to 10%or 3/4 pint(380 mL)with No.3 Thinner. POT LIFE 8 hours at 77°F(25°C)and 50%R.H. Caution:This product cures with moisture acting as a catalyst Incorporation of moisture or moisture laden air(humidity)during use will shorten pot life.Avoid continual agitation at high RPM.When feasible keep containers of mixed material covered during use. APPU(AIION EQUIPMBIT Note:When finish coats are white or light colors,best hiding of this dark color primer can be achieved by spray application. Air Spray Gun Fluid Tip Air Cap Air Hose ID Mat'l Hose ID Atomizing Pot Pressure Pressure DeVilbiss 5/16"or 3/8" 3/8"or 1/2" 40-50 psi 10-20 psi JGA t E 765 or 704 (7.9 or 9,5 mm) (9'Smm)or 2.7 (2.8-3.4 bar) (0.7-1.4 bar) t(with heavy mastic spring)Low temperatures or longer hoses will require additional pressure.Use pressure pot equipped with an agitator and keep pressure pot at same level or higher than the spray gun.Compressed air must be dry. Airless Spray Tip Orifice Atomizing Pressure Mat'l Hose H) Manifold Filter 0.017"-0.021° 2400-3000 psi 1/4"or 3/8" 60 mesh (430-535 microns) (165-207 bar) (6.4 or 9.5 ram) (250 microns) Reversible Tip Use appropriate tip/atomizing pressure for equipment,applicator technique and weather conditions. Keep material agitated to prevent settling. Roller.Use 1/4"or 3/8"(6.4 ram or 9.5 mm)synthetic woven nap roller covers.Stir material frequently or keep under agitation to prevent settling. Brush:Use high quality natural or synthetic bristle brushes. SURFACE TEMPERATURE Minimum 35°F(2°C) Maximum 140°F(60°C) Maximum for Brush&Roller 120°F(49°C) The surface should be dry and at least 5°F(3°C)above the dew point.Note:Series 44-710 Accelerator must be used if the surface temperature is 35°F to 60°F(2°C to 16°C)and 20%to 40%relative humidity. AMBIENT HUMIDITY Minimum 20% Maximum 90% CLEANUP Flush and dean all equipment immediately after use with the recommended thinner or xylene. CAUTION Dry overspray can be wiped or washed from most surfaces.Satisfactory dry-fall performance depends upon height of work,weather conditions and equipment adjustment.Low temperature is of particular concern.Test for each application as follows;Spray from 15 to 25 feet towards paint container.The material then should readily wipe off.Note:Heat can fuse-dry overspray to surfaces.Always clean dry overspray from hot surfaces before fusing occurs.Be aware that surface temperatures can be higher than air temperatures. WARRANTY&LIMITATION OF SELLER'S LIABILITY:Tnemec Company,Inc.warrants only that its coatings represented herein meet the formulation standards of Tnemec Company,Inc.THE WARRANTY DESCRIBED IN THE ABOVE PARAGRAPH SHALL BE IN LIEU OF ANY OTHER WARRANTY,EXPRESSED OR IMPLIED,INCLUDING BUT NOT LIMITED TO,ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.The buyer's sole and exclusive remedy against Tnemec Company,Inc.shall be for replacement of the product in the event a defective condition of the product should he found to exist and the exclusive remedy shall not have failed its essential purpose as long as Tnemec is willing to provide comparable replacement product to the buyer.NO OTHER REMEDY(INCLUDING,Br NOT LIMITED TO,INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR LOST PROFITS,LOST CAT ES,INJURY TO PERSON OR PROPERTY,ENVIRONMENTAL INJURIES OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL LOSS)SHALL BE AVAILABLE.TO THE BUYER Technical and application information herein is provided for the purpose of establishing a general profile of the coating and proper coating application procedures.Test performance results were obtained in a controlled environment and Tnemec Company makes no claim that these tests or any other tests,accurately resent all environments.As a..11cation,environmental and des:n factors can va si:Brand,due care should be exercised in the selection and use of the coatin 6800 Corporate Drive Kansas City,Missouri 64120-1372 1-800-1NEMECI Fox: 1-816.483-3969 www.tnemec.(om ©August 5,2015 by Tnemec Company Inc. PDS9097 Page 2 of 2 CUSTOM PIPE a PABRICATIOf Inc. CERTIFICATE OF MS COMPLIANCE • Pipe is manufactured in accordance with ANSI/AWWA C151/A21.51 Class 53 minimum pipe class used for fabrication, thicker classes available upon request. • Flanged pipe is manufactured in accordance with AWWA/ANSI C115/A21.15 and ANSI B 16.1 • Pipe is manufactured by ACIPCO. • Flanges are manufactured by Tyler Union. • Pipe grooved depth dimension is manufactured in accordance with all applicable requirements of ANSI/AWWA C606 • Pipe interiors coated with asphalt are in accordance with NSF/ANSI 61 • Pipe requiring cement linings are manufactured in accordance with the requirements of ANSI/AWWA C104/A21.4 • Induron Protecto 401, Ceramapure PL90&Ceramawrap linings and coatings are applied to pipe in accordance with Induron specifications. • The exterior of pipe is coated in accordance with ANSI/AWWA C151/A21.51 • All flanges are ductile iron hi-hub with(NPT)tapered threads in accordance with ANSI B 1.20.1 • All ductile iron flanges and pipe for fabricated spools, will be DOMESTIC. Material will meet AIS requirements. • Material is fabricated in the USA at one of the 8 locations noted below. • Each pipe barrel is threaded to match the assigned flange, a 2 part epoxy is applied to both surfaces, then tightened and two holed to the other flange if applicable. • Pipe and flange are faced together after fabrication in order for the gasket to seat properly. Cordially, Kathy Olsen �E at�fy e�aaa, Custo Pipe&Fabrication Inc. Arizona California California Florida New Mexico Oregon Texas Texas Phoenix Fresno Stanton Plant City Clovis Woodburn Conroe Lubbock 602.276.2944 559.834.1342 800.553.3058 813.752.1999 575.769.1961 503.981.0223 936.539.2210 800.460.4906 Page 1 CUSTOM PIPE a PAI3RICATIOn Inc. Arizona California California Florida New Mexico Oregon Texas Texas Phoenix Fresno Stanton Plant City Clovis Woodburn Conroe Lubbock 602.276.2944 559.834.1342 800.553.3058 813.752.1999 575.769.1961 503.981,0223 936.539.2210 800.460.4906 Page 2 GN71t IRO M E�,D1"e'33 800-626-4653 I www.ejiw.com MADE IN USA S8 rn PRODUCT NUMBER xi g 1 00363912 I' CATALOG NUMBER li FRONT VIEW '' 3639Z1 18T 18"VALVE BOX �y TOP SECTION obi LOAD RATING ; j m =1 HEAVY DUTY I COATING DIPPED BACK VIEW ESTIMATED WEIGHT 18" TOP: 43 LBS 19kg [457mm 5/16" ` MATERIAL SPECIFICATION [Bmm]/j T TOP SECTION—GRAY IRON 1" I ASTM A48 CL358 0 7 7/8" 0 7" [25mm] 0 8" 0 12" [200mm] [178mm] [203mm] [305mm] OPEN AREA 1 N/A ',DESIGNATES MACHINE SURFACE 0 7 5/B" I 1" 3/8" DRAWN DATE [194mm [25mm] [10mm]'{I` TLC 11/07/05 LAST REVISED DATE SECTION VIEW SMH 01/31/07 REFERENCE INFORMATION - 00363912.1C CONFIDENTIAL: TIA.drawing Ft the property of east Jordan Fan Wert.,Inc.and embodies 00363912.1D \ conflOwntld Information,bade*eon'Warmer/on,old/or Fmo he.that le the property of raft Jordan Iran Waite,he.0 Copyright 2X1 East Jordon Iron Wake,Inc. \ I EllWIRON WORKS nt 800-626-4653 www.ejiw.com g J i q - - MADE M USA r \0, PRODUCT NUMBER CD00363926 •' I CATALOG NUMBER �W .' ,' 3639A1 u s A 1 1/2" RAISED LETTERING VALVE BOX PLAN VIEW 3/8 COVER BOTTOM VIEW LOAD RATING HEAVY DUTY 7 3/4" DIA COATING DIPPED in ESTIMATED WEIGHT 3/4" COVER: 14 LBS 2 1/2" MATERIAL SPECIFICATION 6 1/2" DIA COVER — GRAY IRON cj ASTM A48 CL358 SECTION VIEW ~' 1" OPEN AREA N/A q'`�/ 2" .: ' J DESIGNATES MACHINED 1" `+�'/�� ' DRAWN DATE R 1/2" „-- I �— 1 3/4" TCL 12/os/o5 R 2 LAST REVISED DATE DEW 07/1 1/07 PICKBAR DETAIL REFERENCE INFORMATION (PICKBAR CORE #11062012) 00363926.IC ooKreamr, nr*Wei r a■nw.b a Ent J.Yw...W,r,he.K+.Kb.ew 00363926.3D STAINLESS STEEL SUMP PUMPS MYERS® DS SERIES .4 The Myers DS series pumps are designed for basement sumps, but are also ideal for dewateringO. '"' duties in a variety of applications. This versatile pump features ! . , 4 stainless steel construction for , f extreme resistance to corrosive environments and will provide years of superior service. .1 lg.- APPLICATIONS i 1` Basement sumps, dewatering, utility `` a SPECIFICATIONS - - Capacities-45 GPM [170.3 LPMI Shut-off Head-26' [98.4 m) FEATURES Operation-On: 13.5" [342.9 mml Versatile Performer Double-protected Motor Off: 6.75" [171.5 mml Ideal for dewatering in construction Long-life carbon/ceramic seal and Solids Handling-3/4" [19 mml sites, ponds, pits,tanks and water additional lip seal protect motor Liquids Handling-Drain water extraction from foundations and against water leakage Continuous Liquid Temperature- flooded basements 1 D4°F(40°C) Extended Service Stainless Steel Tough Fully lubricated bearings and shaft Motor/Electrical Data - 1/3 HP,2.7A; Stainless steel housing and volute seal for longer service life 1/2 HP,4.BA;3/4 HP,6.4A, 115V;60Hz, case resist corrosion and withstand permanent split capacitor type,3450 RPM Smooth Operation P P YP the harshest conditions Impeller is designed for clog Acceptable pH Range-5-9 Powerful Start-ups resistance and effectively handles Shaft Seal-Dual lip with ceramic High-torque, permanent split solids up to 3/4" in diameter shaft seal capacitor[PSC) motor; no relays or Housing-Stainless steel Fittings Included starting switches to wear out 1-1/4"NPT x 1-1/4"NPT 90°discharge Power Cord- 15',SJTW, 18/3 Runs Cooler elbow, 1-1/4" NPT x 1-1/2"adapter Discharge,NPT- 1-1/4" Rugged, oil-filled motor for continuous Min.Sump Diameter- 14" bearing lubrication and maximum heat dissipation ORDERING INFORMATION Approx. Catalog Phase/ Discharge Switch Cord Wt. Number HP Volts Cycles Amps Size Type Length Lbs. I0S33P1 11/3 115 1/60 2.7 1-1/4'. Automati Tetheredc* 15. 13 0550P1 1/2 115 1/60 4.8 1-1/4- Aut Tethered omatic* 15' 16 DS75P1 3/4 115 1/60 6.4 1-1/4'. TetheredAutomatic* 15. 19 'Piggyback PENTAIR , STAINLESS STEEL SUMP PUMPS MYERS® DS SERIES PUMP PERFORMANCE Capacity liters per minute 0 20 40 60 B0 100 120 140 160 180 I I 1 I I I I I I 1 25 20—_ C::: _6 .`...... ,5111111121M111111111111111—6 ■,'., ,►°S)S, ii 4 c L to '1■.,�■ s° 5d 574 NM ■. ., 2 mu-mu -1 0 0 0 10 20 30 40 50 Capacity gallons per minute ►� PENTAIR USA CANADA 293 WRIGHT STREET,DELAVAN,WI 53115 WWW.FEMYERS.COM 490 PINEBUSH ROAD,UNIT 4.CAMBRIDGE,ONTARIO N1T OAS PH:888-987-8677 ORDERS FAX:800-426-9446 PH:800-363-7867 ORDERS FAX:888-606-5484 Because we are continuously improving our products and services,Pentair reserves the right to change specifications without prior notice. 0 2014 Pentair Ltd.All Rights Reserved. ft9016SSE 10EP30/141 The Industry's Most Advanced Fire Hydrant LA It .,,, ,':: , :,.. gir:i_ H Y D . ..... . _, _ . .. , - ' . , �a l I d1.• 7jir fj �r 0 APP® o ~ 1 SETTING A NEW STANDARD FOR FIRE PROTECTION AWWA C502 • Has earned both Underwriters Laboratories and FM approval • 250 PSI working pressure • 10-year limited warranty LA v V rM, VALVE CO. ,WANE Clow Valve AS a division of MCWane.Inc. For Generations www.clowvalve.com ' ENGINEERING FEATURES I MOISTURE PROTECTION ' &�� ANTI-FRICTION Durable cast iron weather cap Thrust bearings above and below combines with one piece copper alloy the copper alloy thrust collar provide operating nut and 0-rings to provide \ I ibillow-torque operation even at 250 PSI reliable, corrosion-free oper under all weather connditiolns.on , working pressure. �( E BONNET SEALS LUBRICATION RESERVOIR � 4114 i Standard 0-rings secure mating 0-ring sealed reservoir may be filled r flanges and sealing throughout easily without disassembly. q LL �' the Medallion.All 0-rings are dependable and easy to replace. TGIC Coating provides a longer lasting COPPER ALLOY NOZZLES more durable finish. Mechanically locked, corrosion- Co NEE resistant,field-replaceable copper • 0ETAIL alloy nozzles have 0-ring seals for STAINLESS STEEL SAFETY STEM water-tight connections. COUPLING SYSTEM r Breakaway parts shear cleanly 1 �_ .i _j ��� I below the top of the barrel,preventing • DRAIN VALVE nozzle section damage or opening Rubber valve facing provides tight, of the main valve. long life seal. Copper alloy seat ring has 360 degree drain channel. Double COPPER ALLOY UPPER ports flush with each use. VALVE PLATE Solid design for added strength LOWER VALVE PLATE and durability. Bottoms out in the ductile iron shoe. Prevents seat from falling below the COPPER ALLOY TO seat ring. COPPER ALLOY Copper alloy seat ring threads NUTS &BOLTS into copper alloy drain ring for All fasteners below grade are corrosion-free protection. stainless steel. COMPRESSION SEATING DUCTILE IRON HYDRANT SHOE High-durometer rubber valve Shaped for low turbulence and closes with the water pressure maximum flow,the shoe is offered in for a positive seal. a variety of end connections.Comes standard wfepoxy coating inside PADS y ¢ and out. Pads on hydrant shoe give large Y, ry 'i ; ._ surface areas for standing and z i /r�� . blocking hydrant. ____ .., PRODUCT DATA PRESSURE LOSS VS. FLOW RECOMMENDED SPECIFICATIONS 1. Fire hydrant shall be manufactured in accordance with AWWA Standard C502,he AWWA LIMIT , listed by Underwriters Laboratories,Inc.and 5 be FM Approved. 2. Fire hydrant shall be designed for 250 PSI working pressure and tested to 500 PSI hydrostatic pressure. 4 3. Fire hydrant shall be backed by manufacturer's 10-year limited warranty. 3 4. Fire hydrant shall be dry-top,center stem, 2-2 I/2'HOSE NOZZLES 4-bolt bonnet construction having an 0-ring AWWA MIT sealed lubrication reservoir. 2 5. Fire hydrant shall be manufactured with t-z1/2'HOSE NOZZLE operating nut and thrust nut made of copper alloy,with bearings located both above and AWWA LIMIT below the thrust collar and with operating 4 I/2'PUMPER NOZZLE nut protected by a cast-iron weather shield. 6. Fire hydrant shall be manufactured with e nozzles mechanically locked into the nozzle o 200 400 600 800 1000 section and having 0-ring seals. FLOW(GPM) 7. Fire hydrant shall be a "Traffic Model," ACCESSORIES complete with safety flanges and stainless steel stem coupling.Nozzle section must rotate 360 degrees. SEAT REMOVAL WRENCH—A light-weight universal combination tool is used to remove the main valve components.The copper 8. Fire hydrant shall be manufactured with alloy seat ring unthreads from the drain ring by engaging the a main valve seat ring of copper alloy wrench with the upper stem pin. threaded into a copper alloy drain ring. A 360-degree drain channel shall have a THRUST NUT WRENCH—The wrench fits the thrust nut for minimum of two tapped drain outlets. easy removal. 9. Fire hydrant shall have a solid copper alloy LUBRICATION—The lubrication reservoir is filled with grease upper valve plate with two rubber facings during manufacture.To add lubrication,remove the weather that activate the drain ports. cap and put the lubricant into the reservoir through the opening on the top of the operating nut,or remove operating nut and fill 10. Fire hydrant shall be manufactured with a lubrication reservoir with food grade grease or oil. lower valve plate that bottoms out in the shoe for a maximum opening.Both lower EXTENSION KIT—Contains everything required to extend the valve plate and shoe shall have fusion stem and barrel.Available in 6" increments. bonded epoxy coating. SAFETY FLANGE REPAIR KIT—Includes safety flange,stem 11. Fire hydrant shall be manufactured with a coupling and pins,flange 0-rings,all bolts, nuts and hardware main valve opening of 41/2"or 51/4". to repair a hydrant damaged due to a traffic accident. 12. Nozzle section shall be coated inside and MAIN VALVE SEAT REPAIR KIT—Contains two drain valve out with TGIC coating. facings and pins,seat ring 0-rings,lower valve plate lock 13. Fire hydrant shall be the Clow Medallion washer,main valve seat, container of lubrication. as manufactured bythe Clow Valve Company BONNET REPAIR KIT—Complete with 0-rings for the bonnet, or approved equal. stem and thrust nut.Operating nut thrust washers and lubrication. ` ES-757DCDA/757NDCDA For Non-Health Hazard Applications Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Series 757DCDA, - - =� 757NDCDA r- 1 Double Check Detector Assemblies Sizes: 21/2"-10" (65-250mm) a Series 757DCDA, 757NDCDA Double Check Detector It = Assemblies are used to prevent backflow of non-health hazard pollutants that are objectionable but not toxic, from entering the potable water supply system.The 757DCDA, 757NDCDA may be installed under continuous pressure service and may 757DCDAOSY be subjected to backpressure and backsiphonage. Series 757DCDA, 757NDCDA is used primarily on fire line sprinkler systems when it is necessary to monitor unauthorized use of 3. water. r._-_ ;_ r �, ,,y.+ 11 4 Features - • Extremely compact design •. • 70% Lighter than traditional designs • 304(Schedule 40)stainless steel housing &sleeve - • Groove fittings allow integral pipeline adjustment 757DCDABFG • Patented tri-link spring check provides lowest pressure loss • Unmatched ease of serviceability •Available with grooved butterfly valve shutoffs • May be used for horizontal, vertical or N pattern installations j • Replaceable check disc rubber Specifications .i A The Double Check Detector Assembly shall consist of two � •independent tri-link check modules within a single housing, � sleeve access port,four test cocks and two drip tight shutoff •� .ii valves.Tri-link checks shall be removable and serviceable,with- out the use of special tools.The housing shall be constructed 757NDCDAOSY of 304 Schedule 40 stainless steel pipe with groove end con- nections.Tri-link checks shall have reversible elastomer discs and in operation shall produce drip tight closure against reverse NOTICE flow caused by backpressure or backsiphonage.The bypass The information contained herein is not intended to replace the assembly shall consist of a meter,which registers in either gal- full product installation and safety information available or the Ion or cubic measurement, a double check backflow assem- experience of a trained product installer.You are required to bly and required test cocks.Assembly shall be a Watts Series thoroughly read all installation instructions and product safety 757DCDA, 757NDCDA. information before beginning the installation of this product. Watts pronuct T lions in U.S.cus W try units and m h are change or te many are uct d forconstruction, only.For precise measurements, ` ® please contact Watts TechNcal Service.Watts reserves the right to or modify product design,corestrucfion,specifications,or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. -Available Models Materials Suffix: Housing&Sleeve:304(Schedule 40)Stainless Steel OSY— UUFM outside stem and yoke resilient Elastomers: EPDM, Silicone and Buna-N seated gate valves Tri-link Checks: Noryl®, Stainless Steel BFG— UUFM grooved gear operated butterfly valves Check Discs: Reversible Silicone or EPDM with tamper switch Test Cocks: Bronze Body Nickel Plated *OSY FxG— Flanged inlet gate connection and grooved outlet Pins&Fasteners: 300 Series Stainless Steel gate connection Springs: Stainless Steel 'OSY GxF— Grooved inlet gate connection and flanged outlet gate connection Pressure — Temperature 'OSY GxG— Grooved inlet gate connection and grooved outlet Temperature Range: 33°F—140°F(0.5°C—60°C) gate connection Maximum Working Pressure: 1 75psi(12.1 bar) Available with grooved NRS gate valves-consult factory' Post indicator plate and operating nut available-consult factory* Approvals `Consult factory for dimensions •Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The Unversity of Southern Dimensions — Weight California(FCCCHR-USC) •AWWA C551-92 "4�P56/po, ® el® D U� . ApprovedC US 1048 B64.5 ("BFG&OSY Only) —r 1 iPi 1 [n rl MIC(open) ,�1 -• I tnI li.j.k 1111111111"H- 8011 -I- A L..L_ G-- --------------------- ------- P ------- 757DCDA, 757NDCDA SIZE(DN) DIMENSIONS WEIGHT A C(OSY) D G H I J P 757DCDA 757NDCDA In. mm In. mm In. mm in. mm In. mm In. mm In. mm In. mm in. mm lbs. kgs. lbs. kgs. 21/2 65 30% 781 16% 416 31/2 89 29'/6 738 211/2 546 151/2 393 813/6 223 133/6 335 139 63 147 67 3 80 31% 806 187/8 479 311/16 94 30% 76B 221/4 565 17% 435 93/8 233 14% 368 159 72 172 78 4 100 33% 857 22% 578 4 102 33 838 231/2 597 181/2 470 913/4n 252 153/8 386 175 79 198 90 16 150 431/2 1105 30% 765 51/2 140 443/4 1137 331/4 845 233/6 569 13'/i6 332 19 483 309 140 350 1591 8 200 49% 1264 37% 959 6t1/46 170 54%8 1375 401/8 1019 277/6 697 15"/6 399 213/6 538 494 224 569 258 10 250 573/4 1467 45% 1162 83/16 208 66 1676 491/ 1257 3212 826 176/6 440 24 610 795 361 965 438 si. A.A A. EII�� �t�17mill D _'.•il 1. 757DCDABFG, 757NDCDABFG SIZE(DN) DIMENSIONS WEIGH& A C D G H I J P 757DCDABFG 757NDCDA BF6 in. mm In. mm In. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. kgs. lbs. kgs. 21/ 65 273/4 705 8 203 31/2 89 297/6 759 21%2 546 1416/6 379 813/6 223 13 330 70 32 78 35 3 80 2814 718 85/16 211 311/6 94 301'/6 779 221/4 565 157/6 392 93/6 233 131/2 343 68 31 81 37 4 100 29 737 813/46 227 31%6 94 3115/6 811 231/2 597 161/4 412 9'36 252 14 356 75 34 98 44 6 150 361/2 927 10 254 5 127 433/6 1097 331/4 845 191%6 500 131/6 332 141/2 368 131 59 171 78 8 200 423/4 1086 121/4 311 61/2 165 511A6 1297 40'% 1019 2336 592 151%6 399 183/6 462 275 125 351 159 Noryl5'is a registered trademark of General Electric Company. * * Capacity Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps Series 757DCDA, 757NDCDA flow curves as tested by • Service Flow is typically determined by a rated Underwriters Laboratory. velocity of 7.5fps based upon schedule 40 pipe. • Rated Flow identifies maximum continuous duty Flow characteristics collected using butterfly shutoff valves performance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. Horizontal Vertical N -Pattern • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 10fps. 21/2" (65mm) 6" (150mm) psi Service Flow Rated Flaw 'IL Rated Flow psi Service How Rated How 'UL Rated Flow 14 12 N 12 _... •N 10 V f ia�'���� ••- '_ -s 6 .ter 2• = 6 _ _P 4 4 Rt 2 0 0 1 0 50 100 150 200 250 300 350 gpm 0 300 600 900 1200 1500 gpm 0 190 380 570 760 950 1140 1330 Ipm 0 1140 2280 3420 4560 5700 Ipm 7.5 15 fps 7.5 12 fps 3" (80mm) 8" (200mm) P2 Service Flow Rated Flow 'UL Rated Flow pZ Service Flow Rated Flow *UL Rated Flow 1N 10 H 10 - V 0 8 __��'• y N, c, 6 .. - C 2 `\ _ '' J llr oE o6 0 6 �? �i as 2 d _ 2 0 0 0 100 200 300 400 500 gpm 0 500 1000 1500 2000 2500 gpm 0 380 760 1140 1520 1900 Ipm 0 1900 3800 5700 7600 9500 Ipm 7.5 15 fps 7.5 10 fps 4" (100mm) 10" (250mm) psi Service Flow Rated Flow *UL Rated Flow P 2 Service Flow Rated Flow 11L Rated Flow 24 20 N 10 w N ice . H 16 H 8 • 12 �" ER 6� �� � v c o '< 2 0 0 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 Ipm 0 500 1000 1500 2000 2500 3000 3500 gpm 7.5 13 fps 0 1900 3800 5700 7600 9500 11400 13300 Ipm 7.5 10 fps NOTICE Inquire with governing authorities for local installation requirements A WARNING It is illegal to use this product in any plumbing system providing water for human consumption,such as drinking or dishwashing,in the United States.Before installing standard material product,consult your local water authority,building and plumbing codes. 2" GRATE — F.B. i" x 1i" STRAP — F.B. x 1" NOTES: 21"0 I MATERIAL: 10 GUAGE PLAN VIEW ASPHALT DIPPED 22"0 L J "L" 2" x 2" x 14" .-ACV O7 ti 18"0 ELEVATION 18"0 VAULT SUMP TUALITIN VALLEY WATER DISTRICT DWG # PROJ. MAN. DOUG P. DWN. PAUL G. SCALE NONE Z T Gibson Steel Basins DATE: MAY 17, 06 MODEL: GSB—VSB �/ SINCE 1972 247 Washington St. Eugene. Or. 97401 ph:(541) 687 — 8672 fax:344-0207 • • • BIRUCRMAI.NOTES 1. CRICKETS 6'-0' E A ss DRYWMREMNR G A Arm RlRe•4600 PSI POIa STIPPND SOTENGW1c•LEO PM _7'I 5'-6"ro Y r CCATMG OM L IEN•ORCRIG — FX7ETU MMOR EMES A AMR AM5 OR A.706 GRACE 3-7 I S D a MSS%ASMMON GRADE dS L MERE ASIR 0150 fiY SUMP Q 2 TON LIFT ANCHORS 4.DESISIE WICEICATON3A CODES: A 01110171,ASM0815 8.USIA COLONS CODE I♦�IM � 4'-ak6-0'z12"SLAB G AASIRD STARDARD SPEOFlGlIW9 FOR MGNWAY ^ eVd^ -e-� :. ..—_ sue- 5V" =GER 1 I !? .}*•N;.;<: %van¢;? ? I M/4242 DOOR a o6 to aN N�R� Q I: y,'w; + i,;s./.�;:;:is;;,,;�: "GALVANIZED C-C ANNFL f ',�I 2'-0 A ASM ORE,ASd DaW �ti+" .;:.l�.V�':.�` a NSM TRUCK*MEL ON,0IM CT `r.}; ,c'. :i7:;;:;;h.: ,,,�;ti.t;, I (EACH END) D,tawDsmevnGxs PeuAartDNe.17 I? I r':':•'•';��:;:;:{•„Y%.::%J:%•%itt$, : I D.8]L 0907W VD PCF IAmalEO) cr.,D.}y s`":.K.a.2.d� ; ''}Ft'"�` E WAIIATAHEIOPOFS7161CDIREV'- .EON v M " I. %f{;:}t} fi `.`:':`:;•:{',;J:( 4., F.DMIAIBNLFMMFF0mFE SUFFFMS t' J . 1;, . �1 ��� G.sa LATERAL FARM PRF86URE(MIN tt: 7. I ve;:x.y.`/ c•C I It CPSTC LIVE LOAD NOT PCJO NVS r` 4/M.•`•" , •• 'j 0, • i' 0.MEGl4RGE LOADS FROM OD ROUIR133 OR .`'" ' fII I. FOONDASURCHARGELOADSFRCIAOOSSSS UCTURE i`tii%%- --...`S1A-1 Q •I 11=-_1==.. II FMmflILN6 ADNLB1EPT A M AUROF 1:1 MS • . 11 'ROM OrHER F0076633 OR ElN1 :1 PAl1oAWAY —�!_�T—. _ 7.DOORS ARE SUdaE FOR NM MMDNG MOMCTIPgf /.� •PVC Id. CIO 001 1 LOCATORS WHERE NOT MEMO TO RiGmcF315fT? USE TSGS-NO 4742 NONSLIP DRAIN II 00 0•l-1I TRAFFIC. ALUMINUM DOUR PLAN VIEW w-I;--VW-A W/SAFETY ORATES 3 SAFETY OWNS SCALE 3/8'•170" p e}43s r amours (42•x4Y CPEMNG) I��1II�I 2 1 END) I_ li.l--1 I 12.08'NNOCNOUf I / �,.: I��I�1; (EACH END) E qI1 e: — I I 2•, f (}20e•r&(4)-4.5'0 N, TERMADUCTS(EACH ENO) L. M--I- t`l 10. e' V-S. pi1G• 660-LA BASE II Ft I s'-o'GALVANIZED c-CHANNEL VIEW B 1 ®� (E CH SIDE) `1'r HOLE PRODUCT WEIGHTS b 1 I I SCALE:3/8"=1'.0" ROD HOLE SECTION WEIGHT i. — TIC I---_-----. ] 6 gARreDDaN LStlIaS. •l l I BA6E S.1tlL6S b Il 100 I__:-___ .-I 01'I TOTAL 7]IOLBS. I 0 L, >o } •' �� 00 I I OO I (16)-HS0 NNOCKOLII3 ICIOldeastle Precast® ,r Ter -.. __ I l I sd (EACH SIDE,MIAOW TAU) AevR.e•uAs NMI n MIM••Iw1•.OaC•III"•s,•A,eat•WYA•r„m• I I R•wuw,•e.mo••,• •IIIsA•ASA.A•m••e••s. "/GALV.PM IRON .•wrA.•Awee.m•n,m•eA; m it l00 I I I O l° (EACH CORNER) «•••.ememanRv5•<•••Aw 00 ; I 00 . 3"DCV Vault 8e0.I.aW14242 DOOR \ .L, susurrrAL •1 I D 6' 1 9' TWNATNW LRISFATNIDRMCT elle,eide• 5'-4•GALVAMZED DOLT-ON LADDER VIEW A W/ALUMINUM EXTEI ON °"n ..,•. °RA'""EP1O`"E� dUL sues. w WI m I N SCALE:air z I'-0• N.wt iavmw swecr 860.L.7W0 MOMS t OF 1 • • NA 7'_g• SINLCMIAL NOTES 1. CONCSIE o NOR A 20 DAY COMPRESSIVE SRBNGIThft.sS00 PSI a bT1111r74STB9IG11t ft.2400 PSI COWSEAL MATT*ON REIAVOICING 1. GROUND E%TNBORE SURFACES Z A.PEDAL AVM AIlS OR M10A SPACES/ ROD HOLE F 72"o SUMP A. MEC<ASM4HC4 GRAMS].CEMEM:ASTIC100 4.DESIGN SpEaseknore8 CODE& tN, � A ASTMOAST,MTAW SPECIFICATIONS ALUMNA TSS-110 4742 NDNSUP B.ACWM SWANS COVE AL WEI DDDR C.AA.SIIIO STAWURp 9P£CRGTION9WMHLAMAY B -------.- w/54E1Y GRATES&SAFETY DANS MOSES ROTC L:S;;S':i."!<.r;Jr;;Tf:�>{`'•'.Yi (4YN2'OPENING) S.DESIGN LOON& >;S:J`'-'iM1+f:. .c` ,''r4,I`",Y,: A ASTM can.ASTI coo `ib,h`;i;}:.% :,i;};2v' A.LOADDOWIBUIONSK LOAD M )M 22(( iM11}M1' ♦ C.LOAD gNSFFC1I@LSPHSWMOIBAT '•.:ti '.i $, M1 ir C.EDKOENVIT':f10POF(.SCSIF®) G. -I }.y ��pp v'c F'':��i„ E.WATERTIBZ ICPCF STRUCME(ASSUE0) 'y'Y v.,r. .:. $$'i.,T,-Z,M1 F.DRY UTEPAI FARM PRESSURE IEEPA40 PCP Rv,. '• •' .{r?,".6°Sk. 11 SA.LATERAL EARIM PIESSEELBPOIp PGF M1"J JJ#, .:': $ M1 M.UTB1ALlNElCAO r4l 'R-}gib,' SS<;: •r f;;,` %3`2 �1 6 DCDV w/FDC Vault 0. PAST DESIGN♦'DOES NOT NCUCIE ANY LAMM OR l B i�i`iW_=__S;;{j: .•r% `e SURCHARGE LOADS FACIA CRF3BARDHR OR FCHICSTICNS=ACMMTT OAS 0IRUCTUf:E MS S STRNCIME SHMI BE IC R A MMUS OF I:I PATO AWAY I .. MAI OTHER FOOTINGS OR FOLAIDATONS ""�� �� T. DOORS ARE=AdE FOR NS20 LOADING N OFF-STREET LOCATIONSN16E NOT SUSECTED TO HONOENSRY .111k A 1RAFFlC. Ii'PVC DRAIN- V 2 TON LIFT ANCHORS IN TOP PLAN VIEW 4 TON UFT ANHORS IN BASE SCALE:5416'=P-0' 7-2'GALVANIZED BOLT-ON LADDER 4.'-B'OB'x12"SLAB WI ALUMINUM EXTENSION W/4242 DOOR Y F III I I 1 F 1D"x24'WAFFLE KNOCKOUT FA I L N r I L (2 PLACES,EACH END) W`/4241PBD s J } r 1 PRODUCT WEIGHTS I IL �)_ Ir — - . . PROMO' MOW I I I - aunt rush S�WI C°C6 81 SID01/021 TOP Mali 1,363 MS. " 181 191 1 1 AT mar e BASE 14=IDS. IMI I ,; n I I b_'@_� TOM. CUM LEA IN I le 0 I I I I I I I I 4 '. 876-I CO Oldcastle Precast® le to I■[[ I•II[■ I o I NM[I#I+Il�il�l�l WA BASE r11ic�coo.110 1 om [[I III[\ I' I I I[II[Il_ I 'mare > :«'a �..we.w R.w'm a I[I•P_ 'N III[■ I' I I ilia• •It, ' .,wowaA1: " La-7-I-Lii--� JI ' a I I 11nWA W!4242 DOOR SUBMTAL c.-- L_I __71—— 1 ISM ISills DRAWN t110.4PM MKi*O Yus• II VI VIEW A 18'424'WAFFLE KNOCKouT VIEW B Tm'1e„6,�W'9,D.,,a,�,r „rW,,,a, .„<AI SCALE.BIAS'=1'.0 (2%ACEG. EACH SIDE) SCALE SAO,.T-0, 878-1-WA-USE 4242.TYWD NNMIf 1 OF 1 • C-0'sue SiRUCRMAI XNFB: I. CONCRETE NOTEA DI DAT COUPEESSME Sf1¢nm Pt fc.S.40I'S1 a SIEMENS STIERGfIt Ism 2a00 P3 ICMVFALUOATTIG RFACES L A.REBECHQ ul' 1' FITE810A SURFACES A IEMASTM A-015 OR MISES GRAM; 1'A GROUND WMEPNNSODA11 a AESI ASV 0.1f061GRIDE85 CN MEMOS SURFACES S.CEMBfT:ASTMG150 ROD HOLE 4. DESIGN SPECIFICATIONS MUSE 11. A AS111 CAA ARTS C41] a AO-11SUYDPIG CODE T. 6 - USF TSGD-16T(4882 NONSLIP AA&NOSTANDARD PEL xAT 049 ORNtlW AT µ. ;,•.,, `--' ALUMNI DOORB✓mGEYDafTI µ' N rI y,, j� a DESIGN WALING: W/SAFETY CRATE&SAFETY CHAINS a ASIM C457,,AMA MI r1rv,'wr +r a Nu01f0ADIUI1OEL LOA USHIDGT �y`.,% • Yr x. '. '••' ryr ' 1 48'x72.CLFM OPENING) C.WAD CIS11NMfRONSPER AISIRDIELI] T,�hf �:Q{ `:� 1?rJ T/1,,{j✓Nl:•��J'�r[� 1.`15 +1Y4'LS+tin YI V eik.:4 4'L'l i+.ti V, v St��r'J t�?''v+ O.sDaDErsNrtm ws C w" vhh ,' ♦ +.+x E. E. 1MTERTALLERIPOF A� +�^. .�:$'y.';i:%%.'ry ttJ•${;1jrirkviii' f.MT UTERN.MTH P1E9aRE CTUIE LEIS PCF) 4V. htr`fi"' ij' i ',v.'. Jv.'`%{ .„i$hk;fvr,;.1'r 1 0.9U&U194L PARTS PRESSURE 115FPkISPCF :•rti11VM1%•"�\.4."til+ !! :':''`l 4, Y.+V fl LITERAL 4LDID SURCHARGE AWEL r:'�i tii}%'`}n{;�n%! 'r;'i:%ii:%%:i$i f�'••rr' 0.PRECISE GELOADC�N OTHER SWINGS 0R i$t$;;" %nv.x•.}4• �}�l'S�„•'JY/fi; L 91N]NNGE LOIDSFPOM OD6t&RmKS OR' } ri:;'xvJ. '+'>•,%,:1:;•`X M'1 h fGIPWTIIXEADUCENTTONE S RUCIIIPE MS t t}k',%U�.•C'h+:C`•` ♦�5• Ci..4CC'KMAA"titN'.;:}'. }�};',"1,°i;:;}:l$%t ,:, :•„ rr'%%%.}f n xv: SIRICRME BULLKL LOAD ARGE IMF H MTq AWAY FICIE ENSITY _ "°v" x'• ''r' 3"Meter Vault COORSA ER EBUTAN FORTs OR V5LOA CNa :i 1'•� T'LOCATIONS WHERE NOT SMELTED 0MW D TRAFFIC. A Ur PYC DRAIN 2 TON UFT ANCHORS IN TOP 4 TON LIFT ANCHORS IN 845E PLAN VIEW SCALE:5115'=Ta 8'-8'GALVANIZED BOLT-ON IADDER W/ALUMINUM EXTENSION C. 18 x24'WAFFLE KNOCKOUT (2 PLACES,EACH END) f IS-8'18'-B'112'SLAB 4 li •• Aam k�� W/4872 ODOR I I sum PRODUCT WEIGHTS 81 ALANT TCP WI DOOR MGM' P_ 9 Ie1 I I 1 AT JOINT 14Solas. I ►tea I I ,., - I8I I 8 TOTAL I5a4OMA3 1 I I I if e ' *we; '� mum I I 5-B IP O1dcastle Precast' I I ' I 'T '5, I I MI�x Iis am ■0� ��41iioos earll ■ , �,...Of..erI.�,IItA.o.m.6 I I 67G1 WA WI 4872 DOOR I I 1 III m L I___, o1- ..L I LJ LL s__ SUBMITTAL MAVEN VALLEY WATER DISTRICT r_,.' ERIEll 1'-C L_4• I 1'-8' I 3-t>f• w5T41EX o.n u,e:Iauw,...NW/PILO= "Xs:. w VIEW A I-18%2e WAFFLE KNOCKOUT VIEW B awe v>,Awwc&NIN •wor� A a� c1a SCALE:E/18'.T-0' (2 PLACES.ace SCALE5118'=Td A�ww 6T&1-WA-NJrD qry wn 1 Of 1 ir Ro K R FIRE DEPT. INLET CONN. EXPOSED TYPE 6405.6425 SERIES ---. SINGLE CLAPPER TWO-WAY INLETS A--I 4 x 2 1/2 x 2 1/2 ii_ lyAn exposed auxiliary inlet connection with 500 G.P.M. inlet capacity to supplement fire protection water supply. Exposed C design provides an economical method of satisfying Fire Dept. Nip '. j inlet requirements. 41 STANDARD EQUIPMENT: Cast brass two-way inlet body -( only with single swing clapper and pin lug swivel back or angle B Figure No. 6405 outlet connection as selected by figure number. 6405 Back Outlet SPECIFY THREAD. BRANDING: "Auto Spkr." FINISH: Cast Brass . 4„H; *WI_LISTED a OPTIONAL FINISHES: PB- Polished Brass RC - Rough Chrome Plated PC - Polished Chrome Plated B Outlet Dimensions 64051 Bacie k 51/4 8 B64 6 iC/2 All: , c 6407 Angle 6 5/16 7 11/16 4 3/4 - L Figure No.6407 6407 Angle Outlet DOUBLE CLAPPER TWO-WAY INLETS Eli ,-, 4 „ `- . An exposed auxiliary inlet connection with 500 G.P.M. Inlet ��1 capacity to supplement fire protection water supply. Exposed A II "F design provides an economical method of satisfying Fire 44414 ' Department Inlet requirements. • 4 STANDARD EQUIPMENT: Cast brass two-way inlet body only `• • with double drop clappers and pin lug swivels; back or angle B Figure No. 6410-6415 outlet connection as selected by figure number. Branding 6410 Back Outlet as selected. SPECIFY THREAD AND BRANDING. BRANDING:"Standpipe", "Auto Spkr." i . >,"?-4% FINISH: Cast Brass o E OPTIONAL FINISHES: PB- Polished Brass RC- Rough Chrome Plated PC- Polished Chrome Plated c Figure No.6420-6425 6420 Angle Outlet *U/L LISTED NY BSA-MEA APPROVED Outlet Style Dimensions Back Angle Size A B C D E *6410 4 X 2 1/2 X 2 1/2 9 5/8 12 1/4 6420 4 X 2 1/2 X 2 1/2 I 11 3/4 9 5/8 7 1/4 6412 d X 21/2X21/2 101/4 11 3/4 6422 6 X 2 1/2 X 2 1/2 12 1/2 10 1/8 7 1/2 6413 4 X 3 X 3 10 121/2 6423 4 X 3 X 3 121/2 101/8 7 1/2 6414 5X 3 X3 101/8 121/2 6424 5 X 3 X 3 121/4 10 1/2 7 1/2 6415 6 X 3 X 3 10 3/8 12 1/2 6425 6 X 3 X 3 12 1/4 10 7/8 7 1/4 Page 6-15 FD ' l'.' ,` '.:04.04t: , 0 . NO" y e McWANE IRON STRONG - DUCTILE V- BIO V-Bio Enhanced Polyethylene Encasement and Corrosion Control W • ,r r+,;,-.,'g McWane Ductile always looks to improve the products and services we provide the water and wastewater industry, especially because municipalities have come to expect a long service life from our ductile iron pipe. Polyethylene encasement is our most popular, economic, and successful method of protecting pipe from corrosion. Since its first water system installation in 1958, polyethylene has been used to protect hundreds of millions of feet of cast and ductile iron pipe in aggressive environments. McWane Ductile is now taking pipe protection to new heights with the innovative V-Bio, an enhanced polyethylene encasement that provides significantly advanced corrosion protection for ductile iron pipe. Specifically, V-Bio addresses the potential influence of anaerobic bacteria and inhibits the formation of corrosion cells under the wrap. Key facts about V-Bio enhanced polyethylene encasement: • Builds upon a proven method of corrosion control — polyethylene encasement —that has been protecting iron pipe from aggressive soils since it was first installed in 1958. • Consists of three layers of co-extruded linear low-density polyethylene film that are fused into one that results in physical strengths up to 40 percent greater than the old polyethylene film, resulting in more damage resistant protection. • Features an inside surface that is infused with a proprietary anti-microbial to mitigate microbiologically influenced corrosion (MIC) and a volatile corrosion inhibitor to control galvanic corrosion. • Addresses two concerns raised over the years— the potential influence of anaerobic bacteria through MIC and the concern about the possibility of corrosion occurring under intact polywrap. • Protects against corrosion without involving consumption or degradation of either the anti-microbial or the corrosion Standard Dimensions and Weights inhibitor. The film's enhanced properties will not wear out! Pipe Size Lay Flat Length Tape Required' Weight • Meets all requirements of the American (In.) size Per Roll' per Joint(ft.) Per Roll' National Standards Institute and the 4 20 500 5 72 American Water Works Association 6 20 500 6 72 (ANSI/AWWA C105/A21.5)standards for 8 20 500 8 72 polyethylene encasement. 10 27 380 9 73.9 • Is the next step in a proven, successful 12 27 380 10 73.9 method of corrosion control. 14 34 300 11 73.44 16 34 300 12 73.44 18 41 260 13 73.8 For more details about V-Bio enhanced 20 41 260 15 73.8 polyethylene encasement,ductile Iron pipe,or 24 54 210 17 81.6 McWane Ductile,visit www.mcwaneductile.com. 30 67 150 21 72.4 36 81 132 25 75.27 ■ D 'Weights and lengths subject to change. IRON STRONG 2Based on one turn at each end,six 4"long strips to secure loose wrap plus MCWANE approximately 5%extra. DUCTILE