Loading...
Plans (4) a CJ3M�l G t4 Roseburg . ;:loam 1 Forest Products Company f of I CS Beam 2016.1.0.13 FEB 0 7 2019 LmBeamEngine 4.13.15.1 61 Materiels Database 1547 t rr: Member Data ern,' 1)� 13�fy�!-1'N." Description: Member Type:Joist Applicatiorll�r- �' ' �`" Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: U480 live, U240 total i Dead Load: 12 PSF Deck Connection: Glued&Nailed Filename: Beam1 1490 1030 9 0 ° 2500 Bearings and Reactions Input Mn Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 2.750" 1.750" 425# -- 2 14' 9.000" Wall DFL Plate(625psi) 3.500" 3.500" 1097# -- 3 25' 0.000" Wall DFL Plate(625psi) 3.500" 1.750" 287# -36# Maximum Load Case Reactions Used for applying pant loads(or line loads)to carrying members Live Dead 1 332#(249p1f) 94#(70pIf) 2 844#(633p1f) 253#(190p10 3 240#(18oplf) 47#(35p1f) Design spans 14' 7.125" 10' 0.375" Product: 9 1/2a" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1302:# 28204 46% 5.99' Odd Spans D+L Negative Moment 1449.'# 28204 51% 14.75' Total Load D+L Shear 605.# 1220.# 49% 14.74' Total Load D+L End Reaction 425.# 1048.# 40% 0' Odd Spans D+L Int.Reaction 1097.# 1775.# 61% 14.75' Total Load D+L TL Deflection 0.2330" 0.7297" L/751 6.72' Odd Spans D+L LL Deflection 0.1866" 0.3648" L/938 6.72' Odd Spans L Control: Max Int React. DOLs: Live=100% Snow=115% Root=125% Wind=160% MST2019-00323-14255 SW 168TH AVE—LOT 67 MST2019-00324-14271 SW 168T"AVE—LOT 68 MST2019-00325-14279 SW 168TH AVE—LOT 69 MST2019-00326-14293 SW 168TH AVE—LOT 70 MST2019-00327-14297 SW 168TH AVE—LOT 71 SIMPSON All product names are trademarks ol their respective owners KAMI L HENDERSON EWP MANAGER StrongTie Copyright(C)2016 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS "Passing is defined as when the member.floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed en this sheet The design BEAVERTON,OREGON must be reviewed bye qualified designer or design professional as required for approval.This design assumes product installation accordng to the manufacturer's specification& 503-858-9663 �4 Roseburg J4 �:osBn, A Forst Products Company 1 or 1 CS Beam 2016.1.0.13 kmBcamEngine 4.13.15.1 fai erials Database 1547 Member Data Description: Member Type: Joist Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: U480 live, U240 total Dead Load: 12 PSF Deck Connection: Glued&Nailed Filename: Beam1 Other Loads Type Other Dead (Description) Side Begin End Start End Start End Category Point(PLF) Top 0' 0.00" 0 80 Live Point(PLF) Top 0' 0.00" 50 34 Roof f 2 0 0 10 5 0 14 3 0 O 2680 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 2' 0.000" Wall DFL Plate(625psi) 5.500" 3.500" 643# — 2 12' 5.000" Wall DFL Plate(625psi) 5.500" 3.500" 1038# — 3 26' 8.000" Wall DFL Plate(625psi) 2.750" 1.750" 418# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Roof Dead 1 367#(276p1f) 82#(62p1f) 276#(207p1f) 2 832#(624p1f) -17#(-12plt) 205#(154p1f) 3 323#(243p1f) 2#(2p1f) 95#(71 p1f) Design spans 2' 0.000"(left cant) 10' 5.000" 14' 1.125" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 12604 2820.'# 44% 20.17' Odd Spans D+L Negative Moment 1318.W 2820.7$ 46% 12.42' Adjacent 2 D+L Shear 582.# 1220.# 47% 12.42' Adjacent 2 D+L Cant.Shear,Lt 290.# 1220.# 23% 1.99' Total Load D+L End Reaction 418.# 1048.# 39% 26.67' Odd Spans D+L Int.Reaction 1038.# 2000.# 51% 12.42' Adjacent 2 D+L TL Deflection 0.2159" 0.7047" L/783 20.17' Odd Spans D+L LL Deflection 0.1684" 0.3523" L/999+ 20.17' Odd Spans L TL Deft,Lt. 0.0458" 2L/999+ 0' Odd Spans D+L LL Defl.,Lt. -0.0327" 2L/999+ 0' Even Spans L Control: Max Int.React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% Left cantilever allowable shear is for joist only SIMPSON All product names are trademarks of their respective omers KAMI L HENDERSON EWP MANAGER Strong-Tie Copynghl(C)2616 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS m s'Passing is defined as when the member,floor joist,p beam a girder,shown on this ova 1,T meets applicable s prod ct installation for Loads,Loading ing!o Conditions,manufacturer's and Spans e listed on this sheet.The design BEAV 8-9663 OREGON must be reviewed by a qualified designer or design pa waional as requretl for approval.This design aromas product installation according ro the manulac[urer's specifications. 503-358-9663