Report (2) FP,SZo/�-00/4/3 /6200 8 tv P'TC/ftc r44W M RECEIVED CO® NOV 2 0 2019 Worldwide www.tyco-fire.com Contacts CITY OF TIGARD BUILDING DIVISION Series DS-1 Dry-Type Sprinklers • 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General having jurisdiction. Failure to do so may impair the performance of these ' i Description devices. The owner is responsible for maintain- TYCO Series DS-1 Dry-Type Sprinklers, ing their fire protection system and 5.6K Pendent, Upright, and Horizontal devices in proper operating condi- Sidewall,Quick Response(3 mm bulb) tion. Contact the installing contrac /, - and Standard Coverage are decora- tor or product manufacturer with any tive glass bulb automatic sprinklers questions. designed for commercial use.Dry-type The Series DS-1 Dry-Type Sprinklers ) sprinklers are typically used where: must only be installed in fittings that • pendent sprinklers are required on meet the requirements of the Design dry pipe systems that are exposed Criteria section. to freezing temperatures (e.g., sprinkler drops from unheated Sprinkler portions of buildings) • sprinklers and/or a portion of the Identification connecting piping are exposed to freezing temperatures;for example, Numbers (SINS) sprinkler drops from wet systems into freezers, sprinkler sprigs 3/4 in.NPT: into unheated TY3935 —Hors Pendent from wet systems TY3735 —HrizontalSidewall • attics, or horizontal piping exten- sions through a wall to protect an 1 in.NPT. unheated areas such as loadingTY3235 —U TY3135 —Uprightpright endent docks, overhangs, and building TY3335 -Horizontal Sidewall exteriors • sprinklers are used on systems that Technical are seasonally drained to avoid Data freezing (e.g.,vacation areas) Approvals NOTICE UL and C-UL Listed Temperature Ratings The Series DS-1 Dry-Type Sprinklers FM Approved Refer to Tables A and B described herein must be installed NYC Approved under MEA 352-01-E Finishes and maintained in compliance with this Previous New York City Approval and Sprinkler:Natural Brass,Chrome Plated, document,as well as with the applica- MEA certification numbers apply to or Signal White ble standards of the National Fire Pro- product as shown in this data sheet. Escutcheon:Signal White,Chrome Plated, tection Association(NFPA),in addition In accordance with Section BC 3502 or Brass Plated to the standards of any authorities of the Construction Code,current NYC Approvals for use in the City of New Physical Characteristics IMPORTANT York apply to all products that contain Inlet Copper Refer to Technical Data Sheet UL or FM Approvals and Listings; Yok Copper gPP g Yoke Stainless Steel TFP2300 for warnings pertaining to therefore, not all products currently Casing Galvanized Carbon Steel regulatory and health information. Approved for use in the City of New Insert Bronze York will carry an actual MEA Certifi- Bulb Seat Stainless Steel Always refer to Technical Data cation number. Bulb Glass Sheet TFP700 for the `INSTALLER Compression Screw Bronze WARNING" that provides cautions Refer to Tables A and B. Deflector Bronze with respect to handling and instal- Maximum Working Pressure Frame Bronze ration of sprinkler systems and corn- 175 psi(12,1 bar) Guidet Tube Stainless Steel ponents. Improper handling and Inlet Thread Connections Spring Stainless Steel installation can permanently damage 3/4 in.NPT Plug Spring' Stainless Steel a sprinkler system or its compo- Sealing Assembly. Beryllium Nickel w/TEFLON - nents and cause the sprinkler to fail 1 in.NPT or ISO 7-R 1 Escutcheon Carbon Steel - to operate in a fire situation or cause Discharge Coefficient 'For 3/4 Inch NPT only . ' it to operate prematurely. K=5.6 gpm/psi1/2(80,6 Ipm/bar1/2) Page 1 of 10 AUGUST 2018 TFP510 TFP510 Page 2 of 10 PLUG WITH ? +P, INLET Operation SEALING i -1 ASSEMBLY111111 t When the TYCO Series DS-1 Dry-Type YOKE Sprinklers,5.6K Pendent, Upright,and 1 4 Horizontal Sidewall, Quick Response PLUG VIM (3 mm bulb) and Standard Coverage SPRING ( 'E� BAND are in service, water is prevented from Ientering the assembly by the Plug with mm, iii Sealing Assembly in the Inlet of the WATER 1 SPRING Sprinkler.See Figures 1 and 2. TUBE 1 CASING The glass bulb contains a fluid that 11111 a expands when exposed to heat.When the rated temperature is reached, the GUIDE 1� _, INSERT fluid expands sufficiently to shatter TUBE 1 the glass Bulb, and the Bulb Seat is released. ULB Ilk SEATThe compressed Spring is then able FRAME 'fe SEAT to expand and push the Water Tube as �I,G0 well as the Guide Tube outward. This 3 mm BULB action simultaneously pulls inward on VENT HOLE 1I� �i1 the Yoke, withdrawing the Plug with lk ig Sealing Assembly from the Inlet and — COMPRESSION allowing the sprinkler to activate and DEFLECTOR ., SCREW flow water. FIGURE 1 Design SERIES DS-1, 3/4 INCH NPT, DRY-TYPE SPRINKLER ASSEMBLY Criteria The TYCO Series DS-1 Dry-Type Sprin- PLUG WITH crkval INLET klers, 5.6K Pendent, Upright,and Hor- SEALING / lir izontal Sidewall, Quick Response ASSEMBLY ; ill' (3 mm bulb) and Standard Cover- il•i4 YOKE age are intended for use in fire sprin- kler systems designed in accordance SPRING _ INLET with the standard installation rules �� recognized by the applicable Listing '.._.�4 BAND or Approval agency; for example, WATER ti1111 iml t UL Listing is based on NFPA 13 requirements. TUBE 1 CASING Sprinkler Fittings Install the 3/4 or 1 inch NPT Series GUIDE t INSERT DS-1 Dry-Type Sprinklers in the 3/4 or TUBE k MI% 1 inch NPT outlet or run of the follow- 1 ing fittings: �� SEAT • malleable or ductile iron threaded FRAME 1pm tee fittings that meet the dimen- kr �i sional requirements of ANSI B16.3 , (Class 150) 111.1 3 mm BULB VENT HOLE ' II • cast iron threaded tee fittings that meet the dimensional requirements COMPRESSION of ANSI B16.4(Class 125) DEFLECTOR __.___ SCREW Do not install the DS-1 Sprinklers FIGURE 2 into an elbow fittings. The Inlet of the SERIES DS-1, 1 INCH NPT AND ISO 7-R 1 DRY-TYPE SPRINKLER sprinkler can contact the interior of the ASSEMBLY elbow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figure 13. You can also install the Series DS-1 Dry-Type Sprinklers in the 3/4 or 1 inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. TFP510 Page 3 of 10 3/4 Inch NPT TY3935 Pendent TY3935 Pendent TY3735 Horizontal Sidewall with Top of Deflector-to-Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 inches (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) without Escutcheon (Figure 10) Temperature Bulb Finish Rating Color Code Natural Chrome White Natural Chrome White Natural Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F(57°C) Orange 155°F(68°C) Red 175°F(79°C) Yellow 1,2 1,2 1*,2* 200°F(93°C) Green 286°F(141°C) Blue Notes: 1. Listed by Underwriters Laboratories,Inc.(maximum order length of 48 inches) 2. Listed by Underwriters Laboratories for use in Canada(maximum order length of 48 inches) Light and Ordinary Hazard occupancies only TABLE A 3/4 INCH NPT SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 1 Inch NPT(and ISO 7-R 1) TY3235 Pendent TY3235 Pendent TY3335 Horizontal Sidewall with Top of Deflector-to-Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 inches (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) TY3135 Upright without Escutcheon without Escutcheons (Figure 10) (Figure 7) Temperature Bulb Finish Rating Color Code Natural Chrome White Natural Chrome White Natural Chrome White Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F(57°C) Orange 155°F(68°C) Red 1,2,3,4 1,2,4 175°F(79°C) Yellow 1,2,3,4 1,2,4 1*,2*,3**,4 1*,2*,4 200°F(93°C) Green 286`F(141°C) Blue 1,2,4 Notes: 1. Listed by Underwriters Laboratories,Inc.(maximum order length of 48 inches) 2. Listed by Underwriters Laboratories for use in Canada(maximum order length of 48 inches) 3. Approved by Factory Mutual Research Corporation(maximum order length of 48 inches) 4. Approved by the City of New York under MEA 352-01-E 5. The Upright Sprinkler without an Escutcheon(TY3135)is available in 1 inch NPT only Light and Ordinary Hazard occupancies only Light Hazard occupancies only TABLE B 1 INCH NPT(AND ISO 7-R 1)SERIES DS-1 QUICK RESPONSE,STANDARD COVERAGE DRY-TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP510 Page 4 of 10 SPRINKLER FITTING SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN (REFER TO DESIGN (REFER TO DESIGN CRITERIA SECTION) CRITERIA SECTION) CRITERIA SECTION) FACE OF \ FACE OF \ FACE OF \ SPRINKLER \ SPRINKLER \ SPRINKLER \ FITTING }}} _ FITTING 'f FITTING } • \ _ __ \ L -J I \ L I ORDER LENGTHS: ORDER LENGTHS: ORDER LENGTHS: 3-1/2" DIA. 2-3/4"to 48" 1-3/4" DIA. 3-3/4"to 48" 1/2"to 46" (88,9 mm) (69,9 to 1219,2 mm) (44,5 44,5 mm) (95,3 to 1219,2 mm) (12,7 to 1168,4 mm) 2-1/2" DIA. IN 1/4"(6,4 mm) IN 1/4"(6,4 mm) 2-1/4" DIA. IN 1/4" (6,4 mm) INCREMENTS INCREMENTS (57,2 mm) INCREMENTS (63,5 mm... ( ____ 1 FACE OF I • • � FACE OF CEILING . FACE OF' CEILING rill I I ��IIIV CEILING ' . . 4-1/4"t 1/8" (108,0±3,2 mm) 2-3/16"±1/8" 3" DIA. 1-3/8"±1/8" 2-7/8" DIA. (55,6±3,2 mm) (76,2 mm) (34,9±3,2 mm) (73,0 mm) l [tit FIGURE 3 FIGURE 4 FIGURE 5 PENDENT TY3235 AND TY3935 PENDENT TY3235 AND TY3935 PENDENT TY3235 AND TY3935 WITH STANDARD WITH RECESSED WITH DEEP ESCUTCHEON ESCUTCHEON ESCUTCHEON SPRINKLER FITTING / (REFER TO DESIGN TOP OF CRITERIA SECTION) DEFLECTOR FACE OF \ SPRINKLER FITTING ORDER LENGTHS: 5"to 48" (127,0 to 1219,2 mm) ORDER LENGTHS: IN 1/4"(6,4 mm) • 5"to 48" INCREMENTS (127,0 to 1219,2 mm) IN 1/4"(6,4 mm) INCREMENTS FACE OF 1 SPRINKLER ow FITTING MINIMUM t - 71-3/4"(44,5 mm) DEFLECTOR TO CEILING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 6 FIGURE 7 PENDENT TY3235 AND TY3935 UPRIGHT TY3135 WITHOUT WITHOUT ESCUTCHEON ESCUTCHEON 1 INCH NPT ONLY TFP510 Page 5 of 10 ORDER LENGTHS: The configuration shown in Figure 12 2-3/4"to 48"(69,9 to 1219,2 mm) is only applicable for wet pipe systems IN 1/4"(6,4 mm)INCREMENTS where the sprinkler fitting and water- _ 2-3/8"t 1/8" filled pipe above the sprinkler fitting are . (60,3±3,2 mm) not subject to freezing and where the FACE OF FACE OF length of the Dry-Type Sprinkler has the — SPRINKLER MOUNTING minimum exposure length depicted in FITTING SURFACE \� Figure 11.Refer to the Exposure Length section. For wet pipe system installations of [ 3" DIA. the 1 inch NPT Series DS-1 Dry-Type (76,2 mm) Sprinklers connected to CPVC piping, ---,-,,,, -' ..--/‘ 3.5° use only the following TYCO CPVC SPRINKLER FITTING 1-3/4"DIA. fittings: (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16" • 1" x 1" NPT Female Adapter (P/N CRITERIA SECTION) OF WATERWAY (7,9 mm) 80145) FTY3335 AND TY3735 Adapter HORIZONAL SIDEWALL GURE 8 • x 1" x Sprinkler Head Adapter Teee (P/N 80249) WITH STANDARD ESCUTCHEON For wet Y pipe e system installations of the the 3/4 inch NPT Series DS-1 Sprin- ORDER LENGTHS: klers connected to CPVC piping, use 1/2"to 45-3/4"(12,7 to 1162,1 mm) in the 3/4"x 3/4" NPT Female Adapter IN 1/4"(6,4 mm)INCREMENTS (P/N 80142). I 4-1/4"t 1/8" 2-1/2" DIA. FACE OF (108,0 t 3,2 mm) For dry pipe system installations, use FACE OF (63,5 mm) MOUNTING only the side outlet of maximum 2-112- SPRINKLER , SURFACE inch reducing tee when locating the FITTING \��\' S} the'es braDS-1 nch line. Otherrinklers wise,tluseelow the ■`� _ configuration shown in Figure 13 to 3-1/2"DIA. assure complete water drainage from IIIIIIIIIIIIII_`jJ (88,9 mm) above the Series DS-1 Dry-Type Sprin- 3.5° klers and the branch line. Failure to do �` ! so may result in pipe freezing and water 10 SPRINKLER FITTING damage. - (REFER TO DESIGN CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) NOTICE FIGURE 9 Do not install the Series DS-1 Dry-Type • TY3335 AND TY3735 HORIZONAL SIDEWALL Sprinkler into any other type fitting WITH DEEP ESCUTCHEON without first consulting the Technical Services Department.Failure to use the ORDER LENGTHS: appropriate fitting may result in one of - 5-1/2"to 48"(139,7 to 1219,2 mm) _ the following: IN 1/4"(6,4 mm)INCREMENTS MINIMUM • failure of the sprinkler to operate 2-1/4"(57,2 mm) properly due to formation of ice FACE OF - - DEFLECTOR TO over the inlet Plug or binding of the SPRINKLER MOUNTING Inlet Plug FITTING SURFACE • insufficient engagement of the Inlet pipe threads with consequent leakage Drainage �, „ �� In accordance with the minimum / 3.5° 5/16„ requirements of the National Fire Pro- (7,9 mm) tection Association for dry pipe sprin- SPRINKLER FITTING (REFER TO DESIGN CENTERLINE kler systems, branch, cross, and CRITERIA SECTION) OF WATERWAY feed-main piping connected to Dry Sprinklers and subject to freezing tern- FIGURE 10 peratures must be pitched for proper TY3335 AND TY3735 HORIZONAL SIDEWALL drainage. WITHOUT ESCUTCHEON Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use TFP510 Page 6 of 10 / - _ RUN FACE OF I I TO WET SIDE O OUTLET SPRINKLER J SYSTEM OUTLET l PLUGGED ' FITTING PLUGGED \ \� , -y r-'' SPRINKLER • HEATED TO DRY FITTING HEATED EXPOSURE AREA (SEE DESIGN AREA LENGTH SYSTEM CRITERIA (SEE DESIGN SECTION) DSB-2 CRITERIA D8B-2 SPRINKLER AREA INTENDED SECTION) INTENDED FITTING SUBJECT DSB-2 FOR FREEZER FOR FREEZER (SEE DESIGN TO INTENDED STRUCTURES STRUCTURES CRITERIA FREEZING FOR FREEZER SECTION) A,STRUCTURES N --'\\ -)7 ir FIGURE 11 FIGURE 12 FIGURE 13 EXPOSURE SPRINKLER FITTING SPRINKLER FITTING LENGTH HEATED AREA UNHEATED AREA STRAP TIES 1-3/4' DIA. • (ENDS ON (44,5 mm) 7 OPPOSING CLEARANCE INSULATED SIDES OF HOLE FREEZER WRENCH BOOT) ADHESIVE STRUCTURE RECESS / /-DSB-2 BOOT DSB-2\ / ADHESIVE BOO., - i , \ IIIMEI il Ail __„_--ADHESIVE CLEARANC1-3/45" DIA.EI WRENCH I �I (44, mm) �III ��I III FLAT I\ 10 ` v HOLE INSULATED \ /I PUSH WRENCH FREEZER 1INTO ENSURE • � STRUCTURE I / ENGAGEMENT STRAP TIES MN DS-1 (ENDS ON DS-1 WITH SPRINKLER g`NO SHOWN WITH OPPOSING SHOWN RIDH WRENCHING AREA STANDARD SIDES OF ESCUTCHEON ESCUTCHEON BOOT) FIGURE 14 FIGURE 15 FIGURE 16 MODEL DSB-2 SPRINKLER MODEL DSB-2 SPRINKLER W-TYPE 7 BOOT WITH PENDENT SERIES BOOT WITH SIDEWALL SERIES SPRINKLER DS-1 DRY SPRINKLER DS-1 DRY SPRINKLER WRENCH TFP51O Page 7 of 10 meet the requirements of the Design Temperatures for Heated Areal Criteria section. Refer to the Design Criteria section for other important Ambient Temperature 40°F 50°F 60°F requirements regarding piping design Exposed to (4°C) (10°C) (16°C) and sealing of the clearance space Discharge End of Sprinkler Minimum Exposed Barrel Length2, around the Sprinkler Casing. - Inches Do not install any bulb-type sprinkler (mm) if the bulb is cracked or there is a loss 40°F of liquid from the bulb. With the sprin- (4°C) 0 0 0 kler held horizontally,a small air bubble should be present.The diameter of the 30°F air bubble is approximately 1/16 inch (-1°C) 0 0 0 (1,6 mm)for the 135°F(57°C) rating to 20°F 4 1/8 inch(3,2 mm)for the 286°F(141°C) (-7°C) (100) 0 0 rating. 10°F 8 1 • A leak-tight 3/4 inch NPT sprinkler (-12°C) (200) (25) 0 joint should be obtained by applying a minimum-to-maximum torque of 0°F 12 3 10 to 20 ft.-lbs. (13,4 to 26,8 Nm). (-18°C) (305) (75) 0 • A leak-tight 1 inch NPT sprinkler -10°F 14 4 1 joint should be obtained by applying (-23°C) (355) (100) (25) a minimum-to-maximum torque of 20 to 30 ft.-lbs. (26,8 to 40,2 Nm). -20°F 14 6 3 Higher levels of torque can distort the (-29°C) (355) (150) (75) sprinkler Inlet with consequent leakage -30°F 16 8 4 or impairment of the sprinkler. (-34°C) (405) (200) (100) Do not attempt to compensate for -40°F 18 8 4 insufficient adjustment in an Escutch- (-40°C) (455) (200) (100) eon Plate by under or over-tightening -50°F 20 10 6 the sprinkler. Re-adjust the position of (-46°C) (510) (255) (150)(-46°C) sprinkler fitting to suit. Step 1. Install pendent sprinklers only -60°F 20 10 6 in the pendent position, and install (-51°C) (510) (255) (150) upright sprinklers only in the upright position.The deflector of a pendent or Notes: upright sprinkler must be parallel to the 1. For protected area temperatures that occur between values listed above,use the next ceiling. _ cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph(18,6 kph). Install horizontal sidewall sprinklers in the horizontal position with their cen- TABLE C terline of waterway perpendicular to EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS the back wall and parallel to the ceiling. MINIMUM RECOMMENDED LENGTHS Ensure the word"TOP"on the Deflector faces the ceiling. Table C to determine a sprinkler's build-up can occur that might damage Step 2. With a non-hardening pipe- appropriate exposed barrel length to the dry-type sprinkler and/or prevent thread sealant such as TEFLON tape prevent water from freezing in the con- proper operation in a fire situation. applied to the Inlet threads, hand- necting pipes due to conduction. The Use of the Model DSB-2 Dry Sprin- tighten the sprinkler into the sprinkler exposed barrel length measurement kler Boot, described in Technical Data fitting. must be taken from the face of the Sheet TFP591 and shown in Figures 14 sprinkler fitting to the surface of the and 15,can provide the recommended Step 3. Wrench-tighten the sprinkler structure or insulation that is exposed l using either: sea. to the heated area. Refer to Figure 11 • a pipe wrench on the Inlet Band or for an example. the Casing (Ref. Figures 1 and 2) Clearance Space Installation • the W-Type 7 Sprinkler Wrench on In accordance with NFPA 13, when The TYCO Series DS-1 Dry-Type Sprin- the Wrench Flat(Ref. Figure 16) connecting an area subject to freez- klers,5.6K Pendent, Upright,and Hori- ing and an area containing a wet pipe zontal Sidewall,Quick Response(3 mm Apply the Wrench Recess of the sprinkler system, the clearance space bulb) and Standard Coverage must W-Type 7 Sprinkler Wrench to the around the sprinkler barrel of Dry-Type be installed in accordance with this Wrench Flat. Sprinklers must be sealed. Due to section. temperature differences between two areas,the potential for the formation of General Instructions condensation in the sprinkler and sub- The Series DS-1 Dry-Type Sprinklers sequent ice build-up is increased. If must only be installed in fittings that • this condensation is not controlled,ice TFP51O Page 8 of 10 Note; if sprinkler removal becomes if they cannot be completely cleaned Ordering necessary, remove the sprinkler using by wiping the sprinkler with a cloth or the same wrenching method noted by brushing it with a soft bristle brush. Procedure above.Sprinkler removal is easier when Care must be exercised to avoid a non-hardening sealant was used damage to the sprinklers before, Contact your local distributor for avail- and torque guidelines were followed. during, and after installation. Sprin- ability.When placing an order,indicate After removal, inspect the sprinkler for klers damaged damage. 9 by dropping, striking, the full product name and Part Number wrench twist/slippage,or the like,must (P/N). Step 4. After installing the ceiling or be replaced. Also, replace any sprin- DS-1 Dry-Type Sprinklers wall and applying a ceiling finish, slide kler that has a cracked bulb or that has When ordering TYCO Series DS-1 on the outer piece of the escutcheon lost liquid from its bulb. (Ref. Installa- Dry-Type Sprinklers, 5.6K Pendent, until it comes in contact with the ceiling tion Section.) Upright, and Horizontal Sidewall, or wall. Do not lift the ceiling panel out The owner is responsible for the Quick Response(3 mm bulb)and Stan- of its normal position. inspection,testing,and maintenance of dard Coverage, specify the following When using the Deep Escutcheon, their fire protection system and devices information: hold the outer piece in contact with the in compliance with this document, as • SIN: mounting surface(ceiling or wall).Then well as with the applicable standards Pendent—TY3935 or TY3235 rotate the inner piece approximately 1/4 of the National Fire Protection Asso- Sidewall—TY3735 or TY3335 turn with respect to the outer piece, ciation (e.g., NFPA 25), in addition to Upright—TY3135 to hold the Deep Escutcheon firmly the standards of any other authorities together. having jurisdiction.Contact the install- • 5.6 K-factor ing contractor or product manufacturer • Deflector Style: Care and with any questions. Upright, Pendent, or Horizontal Automatic sprinkler systems are rec- Sidewall Maintenance ommended to be inspected, tested, • Quick Response, Standard Cover- and maintained by a qualified Inspec- Dry-Type a e, Sprinkler The TYCO Series DS-1 Dry-Type Sprin- tion Service in accordance with local g klers,5.6K Pendent,Upright,and Hori- requirements and/or national codes. • Order Length: zontal Sidewall,Quick Response(3 mm Dry-Type Sprinklers are furnished bulb)and Standard Coverage must be Limited based upon Order Length as maintained and serviced in accordance measured per Figures 3 through with this section. warranty 10. After taking the measurement, Before closing a fire protection system round it to the nearest 1/4 inch main control valve for maintenance For warranty terms and conditions,visit increment. work on the fire protection system www.tyco-fire.com. • Inlet Connections: that it controls, obtain permission to 3/4 in. NPT, 1 in. NPT, or ISO 7-R 1 • shut down the affected fire protection systems from the proper authorities • Temperature Rating and notify all personnel who may be • Sprinkler Finish affected by this action. • Escutcheon Style and Finish, as Absence of the outer piece of an applicable escutcheon, which is used to cover a • Part Number(P/N)from Table D clearance hole, can delay the time to sprinkler operation in a fire situation. The Upright Sprinkler without an A Vent Hole is provided in the Bulb Escutcheon(TY3135)is available in Seat(Ref. Figures 1 and 2)to indicate 1 in. NPT only. if the Dry-Type Sprinkler is remaining Part Numbers are for 3/4 in.and dry. Evidence of leakage from the Vent 1 in. NPT standard order sprin- Hole indicates potential leakage past klers.Orders for all other sprinkler the Inlet seal and the need to remove assemblies must be accompanied the sprinkler to determine the cause of by a complete description. Refer to leakage (e.g., an improper installation the Price List for a complete listing or an ice plug). Close the fire protec of Part Numbers. tion system control valve and drain the Sprinkler Wrench system before removing the sprinkler. Specify: W-Type 7 Sprinkler Wrench, Sprinklers which are found to be P/N 56-850-4-001 leaking or exhibiting visible signs of Sprinkler Boot corrosion must be replaced. Specify: Model DSB-2 Dry Sprinkler Automatic sprinklers must never be Boot, P/N 63 000 0 002 painted, plated, coated, or other- This Part Number includes one (1) wise altered after leaving the factory. Boot, two (2) Strap Ties, and 1/3 oz. Modified sprinklers must be replaced. of Adhesive (a sufficient quantity for Sprinklers that have been exposed to installing one boot). • corrosive products of combustion, but have not operated,should be replaced TFP51O Page 9 of 10 P/N` 60 - XXX - X - XXX i - I SPRINKLER ESCUTCHEON SIN FINISH FINISH.' 01 Pendent with Standard TY3935 SIGNAL WHITE Escutcheon(3/4"NPT) (Figure 3) 0 CHROME PLATED (RAL9003) 02 Pendent with Deep TY3935 1 NATURAL BRASS SIGNAL WHITE Escutcheon(3/4"NPT) (Figure 5) (RAL9003) 03 Pendent with Recessed TY3935 2 NATURAL BRASS BRASS PLATED Escutcheon(3/4" NPT) (Figure 4) Pendent without TY3935 SIGNAL WHITE SIGNAL WHITE 04 Escutcheon(3/4" NPT) (Figure 6) 4 (RAL9003) (RAL9003) 9 CHROME PLATED CHROME PLATED 05 Sidewall with Standard TY3735 Escutcheon(3/4" NPT) (Figure 8) 06 Sidewall with Deep TY3735 TEMPERATURE SAMPLE Escutcheon(3/4" NPT) (Figure 9) RATINGS ORDER LENGTHS2 07 Sidewall without TY3735 0 135°F(57°C) Escutcheon(3/4" NPT) (Figure 10) 055 5.50" 1 155°F(68°C) 082 8.25" 36 Pendent with Standard TY3235 2 175°F(79°C) 180 18.00" Escutcheon(1"NPT) (Figure 3) 3 200°F(93°C) 187 18.75" Pendent with Deep TY3235 - - 33 Escutcheon(1"NPT) (Figure 5) 4 286°F(141°C) 372 37.25" 37 Pendent with Recessed TY3235 480 48.00" I Escutcheon(1"NPT) (Figure 4) 32 Pendent without TY3235 Escutcheon(1" NPT) (Figure 6) 34 Sidewall with Standard TY3335 Escutcheon(1" NPT) (Figure 8) Notes: 43 Sidewall with Deep TY3335 1. Escutcheon Finish applies to sprinklers provided with escutcheons. Escutcheon(1" NPT) (Figure 9) 2. Dry-Type Sprinklers are furnished based upon"Order Length"as measured per Figures 3 through 10,as applicable,and for each individual sprinkler where it is to be installed.After the measurement is taken,round it to the 44 Sidewall without TY3335 nearest 1/4 inch increment. Escutcheon(1" NPT) (Figure 10) Use Prefix"I"for ISO 7-R 1 Connection(e.g.,I-60-010-4-055). 38 Upright without TY3135 Escutcheon(1"NPT) (Figure 7) TABLE D SERIES DS-1 DRY-TYPE SPRINKLERS PART NUMBER SELECTION TFP51U Page 10 of 10 • • • • • 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 o 2058 Johnsen Controls.All rights reserved.all specifications and ether mrnrmetien shown were Current as at document reslslen date and are subject In change without Attlee. Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA arc registered trademarks o'National Fire Protection Association; Controls TEFLON Is a registered Irademark of DuPont Controls