Loading...
Report (2) 4487-2019-00Y5Ce 1562O *1 E-Mregf YE-PRAC - Sheet RECEIVED Enphase Microinverters Region:AMERICAS DEC 1 2019 CITY OF TIGARD BUILDING DIVISION Enphase The high-powered smart grid-ready P Enphase IQ 7X Micro" dramatically simplifies the IQ 7X M icroi nverter installation process while achieving the highest system efficiency for systems with 96-cell modules. Part of the Enphase IQ System,the IQ 7X Micro integrates with the Enphase IQ Envoy", Enphase IQ Battery'",and the Enphase Enlighten" monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple I 1101 • Faster installation with improved,lighter two-wire cabling el • Built-in rapid shutdown compliant(NEC 2014&2017) Efficient and Reliable • Optimized for high powered 96-cell*modules • Highest CEC efficiency of 97.5% • More than a million hours of testing • Class II double-insulated enclosure ENPHASE. s ®IQ • UL listed = E------ „...,1,9..-?1(-=.- Smart Grid Ready nil � 9 !i I (a. • Complies with advanced grid support,voltage and ®mll CL ^..)i ! frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7X is required to support 96-cell modules. SAFEPY US-G E341165 EN PHASE E To learn more about Enphase offerings,visit enphase.com a En phase IQ 7X Microinverter INPUT DATA(DC) IQ7X-96-2-US Commonly used module pairings' 320 W-460 W+ Module compatibility 96-cell PV modules Maximum input DC voltage 79.5 V Peak power tracking voltage 53 V-64 V Operating range 25 V-79.5 V Min/Max start voltage 33 V/79.5 V Max DC short circuit current(module Ise) 10 A Overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @ 240 VAC @ 208 VAC Peak output power 320 VA Maximum continuous output power 315 VA Nominal(L-L)voltage/range° 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 1.31 A(240 VAC) 1.51 A(208 VAC) Nominal frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuits 12(240 VAC) 10(208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor(adjustable) 0.85 leading...0.85 lagging EFFICIENCY @240 VAC @208 VAC GEC weighted efficiency 97.5% 97.0 MECHANICAL DATA Ambient temperature range 40°C to+60°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7X-96-2-US) MC4(or Amphenol H4 UTX with optional Q-DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class 8, ICES-D003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions, 1.No enforced DC/AC ratio.See the compatibility calculator at https://enohase com/en-us/support/module-comoatibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com e EN P H A S E h 2019 Enphase Energy All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2019-3-26