Loading...
Plans (2) CITY OF arc ,: P ;. WFICE COPY . PROJECT INFORMATION REVIEWED FOL' C9DE COMP CE . - 1 OWNER EPSTEIN RESIDENCE CONTRACTOR SUNBRIDGE SOLAR Approved: [ 15520 SW EMPIRE TERRACE 421 C ST, UNIT 5A OTC: [ ] TIGARD, OR 97224 WASHOUGAL, WA 98671 :CENED (541)521-7890 CONTACT: JORDAN WEISMAN Permit #: S"T4<)19 OO - S(o BUILDING SINGLE FAMILY PHONE: (360)313-7190 Address: 1 562.0 Si,,.) CN1pl C. ..1346ILASHFORD ST JEC 12 2019 DATA RESIDENTIAL ROOF SPECS COMPOSITE SHINGLE ROOFING APPLICABLE 2014 OREGON STRUCTURAL 2X4 TRUSSES SPACED C 24" O.C. Suite #: /I CITY OF TIGARD CODES SPECIALTY CODE(SECTION 3111) DOUGLAS FIR#2(TRUE DIMENSION) By: A-� Date: I /(7 f BUILDING DIVISION SYSTEM PANASONIC VBHN320KA03 320W ! ," TILT: 32°, 38° o ��}% ` 24 MODULES AZIMUTH: 270°, 180°, 90° !�.�� • �„ 24 X 320W= 7.68 kW w �,��, +�� . a • :,;�, � 24 ENPHASE IQ7X-96-2-US MICRO-INVERTERS AREA OF ROOF(PLAN VIEW)= 1,750 SF w • -�� 6* -��+f !/ �Y MODULE PANASONIC VBHN320KA03 a %0�E% •. Z. ,' `' , SPECS AREA OF NEW ARRAY=433 SF w ''.,: . l;_ , (L)62.6"X(W)41.5"X(H) 1.50" (ARRAY< 25% OF ROOF AREA) - ' =�iy WEIGHT=41 LBS ° -�� gwri; 017 COMBINED WEIGHT OF MODULES �' Approv nians • AND RACKING =c 4.5 PSF. ,\ ' ,; Thal! be ( :h slf,*_ ./ �J.1 .`_ PROJECT NOTES ;:,(, 1. PV SYSTEMS AND SUPPORTING STRUCTURE UNOBSTRUCTED PATHWAY SHALL BE PROVIDED ,%i SHALL COMPLY WITH REQUIREMENTS OF 2014 IN ADDITION TO A MINIMUM 12"UNOBSTRUCTED �+� �_ "_��al, Y ��r, OREGON STRUCTURAL SPECIALTY CODE PATHWAY ALONG EA. SIDE OF ANY HORIZONTAL 1j�.� �>�/- (SECTION 3111) RIDGE. ":/1�1�1' 2. 3111.3.2- PV RACKING AND ATTACHMENTS SHALL BE UL 6. ROOF STRUCTURE IS CONVENTIONAL LIGHT Utility Dismnnect 1703 CERTIFIED. FRAMED WOOD CONSTRUCTION WITH 2X4 TRUSSES Electrical Panel 3. 3111.3.4- PV SYSTEM SHALL HAVE A FIRE AT 24"O.C. REFER TO ALLOWABLE SPAN Enphase Combirer Box • CLASSIFICATION THAT IS EQUAL TO OR GREATER REQUIREMENTS IN TABLE 305.4.1. Utility Meter ��; THAN THE ROOF ASSEMBLY REQUIRED BY OSSC 7. 3111.4.8.5.1 -DISCONNECTS, J-BOXES, COMBINER -1,,1;.r SECTION 1505.1. BOXES OR GUTTERS SHALL NOT BE PLACED .. �%, �..} �- 4. 3111.4.3- 3111.4.7-PV LAYOUT SHALL NOT RESTRICT IN ANY REQUIRED PATHWAY OR CUTOUT. �� ,�rw'. �,Y� �• EGRESS, LIGHT VENTILATION, OR ROOF DRAINAGE 8. 3111.5.3.1 -TOTAL SYSTEM WEIGHT �: .1 REQUIREMENTS. SHALL NOT EXCEED 4.5 PSF. PV MODULES ,"Wyk. /�r�� ill �%J. 5. 3111.4.8.1 -GENERAL PATHWAY REQUIREMENTS:ALL PV AND RACKING SHALL BE DIRECTLY ATTACHED INSTALLATIONS SHALL INCLUDE A 36 INCH WIDE TO ROOF FRAMINGS AS SHOWN IN PATHWAY MAINTAINED ALONG THREE SIDES OF THE CONNECTION DETAIL#2. ATTACHMENT SOLAR ROOF. SPACING WILL BE 48"O.C. MAX,AND WHEN EXCEPTION 1: ON STRUCTURES WITH A PV ARRAY ATTACHMENT LOCATED WITHIN 3'OF ROOF _ _ AREA OF 1,000 SF OR LESS INSTALLED ON A ROOF EDGE, HIP, EAVE, RIDGE SHALL BE 24"O.C. MAX. ' ��" WITH A SLOPE THAT EXCEEDS 2:12 AND WITH AN 9. 3111.5.4- MAX MODULE HEIGHT< 18"OFF ROOF ':%,1.� INTERSECTING ADJACENT ROOF AND WHERE NO SURFACE. (t. ` SECTION IS LARGER THAN 150 FEET MEASURED IN LENGTH OR WIDTH. EXCEPTION 1.1:WHERE PV ARRAY DOES NOT EXCEED LIABILITY i:'; 25%AS MEASURED IN PLAN VIEW OF TOTAL The City Of Tigard and its '��,�-' ROOF AREA OF A STRUCTURE,A MINIMUM OF 12" ' �" Pmployees shall not be - ..Allf.,` UNOBSTRUCTED PATHWAY SHALL BE MAINTAINED responsible for discrepancies EXCEPTION 1.2:WHERE THE SOLAR ARRAY EXCEEDS which may appear herein, _ 25%AS MEASURED IN PLAN VIEW OF TOTAL ROOF AREA OF THE STRUCTURE,A MINIMUM OF ONE 36" DATE:November 19.2019 I SITE PLAN VALIDITY OF PERMIT C St, 5A THE ISSUANCE OF A PERMIT - ------- - ---•- Washougal,WA 98671 Epstein Residence 4 BASED ON CONSTRUCTION TEL:503-407-6820 15520 SW Empire Terrace hi tits DOCUMENTS AND OTHER WA:421 C St,Unit9882NF Tigard,OR 97224 ll. .' .1 CCB(OR): 198787 (541)521-7890 ii DATA SHALL NOT PREVENT `� OFFICE l THE CODE OFFICIAL FROM REQUIRING THE CORRECTION OF ERRORS. ORSC 105.4 I rt of _ L MP3-SOUTH DORMER , AIO O 0 0-0 0 0 • 0 _ _IIIk TILT:/ AZIMUTH: 180° 0 0 E-- 0 O aik II O O 0 —0 0 / 2F O O 0 ----0 O C' nL _ MP1 / O 0 0 0 TILT: 32° AZIMUTH:270° / C O 0 TRUSS CONNECTION POINTS SPACED @ 48"O.C.MAX. MP2-NORTH DORMER TILT:38° / AZIMUTH: 180° 2X4 PRE-ENGINEERED MANUFACTURED TRUSS SPACED 2,. @ 24"O.C. TRUSS CONNECTION POINTS al — al — 0 — 0 SPACED @ 24"O.C.WHEN WITHIN ___A 36"OF ROOF EDGE Ha- 0 — 0- - -0 0 0 — 0 — 0 - 0 3-0" 0 - 0 - 0 0 MP4 0 TILT:32° AZIMUTH:90° 0 0 DATE:November 19,2019 ROOF PLAN I TILT=32',38° I AZIMUTH=270°,180°,90° 421 C St, Unit 5A Epstein Residence System: �1 Washougal,WA 98671 .W TEL:360.313.7190 15520 SW Empire Terrace 124)Panasonic VBHN320KA0 //� •��� WA: SUNBRSL882NF Tigard,OR 97224 (24)Enphase I07X-96-2-US ..� CCB(OR): 198787 (541)521-7890 7.68 kW `\`�J "'COMPASS IN RELATION TO MP1"" 1 . Roof Detail 2. Connection Detail Scale: NTS Scale: NTS SOLAR COLLECTOR MODULE DIMENSION MODULE(4 PSF, r VARIES I MAX.) II II it _ _ II 14 l i i i I I 1f i I NEW SOLAR MODULE i I4 c I I i II ARRAY AND SEC ON A ._._ ATTACHMENT SYSTEM i TO EXISTING ROOF - CONNECT SOLAR I' 1. TRUSS MODULE TO RAILS A I•, WITH 1 CONNECTOR _14 4- FOR EACH 8.SO FT. rink'iN OR LESS OF MODULE i' O�M):t:� II SURFACE I ! I `:..:*:.�. 30' sV4 CORROSION RESISTANT „, METAL RAIL ANCHOR TO n II „ �' O n ALTERNATE ROOF FRAMING it II 72"MAX.ON CENTER PER EXISTING 2X4 PRE-ENGINEERED SECTIONOV A-MA TYPICAL- MANUFACTURED TRUSS SPACIN MANUFACTURED TRUSSES @ 24" PROVIDE A MINIMUM OF 2 .�— tgp 24"MAX ON CENTER M.C. RAILS PER MODULE. 2 IRONRIDGE CONTINUOUS SUPPORT RAIL AND CONNECTION POST BY RAIL MANUFACTURER v. IRONRIDGE L-FOOT. INSTALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS DATE:November 19,2019 421 C St, Unit 5A Washougal,WA 98671 Epstein Residence TEL (360)313-7190 15520 SW Empire Terrace WA: SUNBRSL882NF Tigard, OR 97224 CCB(OR): 198787 (541)521-7890 3-3 COND.IN CONT. MAX CIRCUIT CONDUCTOR MP. DROP PV CIRCUITS FROM ARRAY TO COMBINER BOX COND.1D 10 AWG PV VV1RE,Cu CONDUIT CONDUIT 6 AWG BARE,COPPER CURRENT CUR5AANT 30.4 AED LENGTH 0.97%T RECEIVED INVERTER TO 200A SERVICE PANEL 8 AWG THWN-2,CU 3 3/4'EMT 6 AWG BARE,COPPER 31.44A 39.3A 43.5A 10 FT 0.20% DEC 12 2019 INTERNAL VOLTAGE DROP WITHIN CABLING=0.72% CITY OF TIGARD TOTAL VOLTAGE DROP=1.89% BUILDING DIVISION AC DISCONNECT WITHIN 10 FT OF UTILITY METER MODULES& ENPHASE MICRO-INVERTERS COMBINER 200A SERVICE BOX PANEL BOA NON FUSED INTERCONNECTION Stung Size:12 modules ••— AC DISCONNECT 200A Main _ gY 40A CIRCUIT 120/240 VOLT, Breaker // BREAKER + - r / THREE-WIRE,SINGLE-PHASE C) O O Utility Skiing Size:12 modules ••— V_ [ N #6 BARE COPPER GROUNDING ELECTRODE VOLTAGE DROP CALCULATION NEC PV LABELING REQUIREMENTS 1.INTERNAL VOLTAGE DROP WITHIN CABLING OMAIN PANEL PLACARD(NOT REQUIRED) iJ JUNCTION BOX&AC DISCONNECT&PANEL 12 micro inverters per branch circuit=0.72% PV SYSTEM CHARACTERISTICS &UTILITY DISCONNECT(690.17)(PLACARD) 7.68 KW SOLAR ELECTRIC SYSTEM 2.VOLTAGE DROP FROM SOLADECK TO ENPHASE °MODULES(690,51) 24 PANASONIC VBHN320KA03 320W SOLAR MODULES I WARNING:ELECTRICAL SHOCK HAZARD COMBINER 24 ENPHASE 107X-96-2-US INVERTERS DO NOT TOUCH TERMINALS. 12 mbroinverter circuit: OPERATING CIRCUIT VOLTAGE: 70.5 V TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE OPERATING VOLTAGE: 58.7 V bb�� ENERGIZED IN THE OPEN POSITION. %Vdrop=(1.31 A'12)'(Y60 6)'(0.00124 ohms/8)1(240 V) MAXIMUM SYSTEM VOLTAGE: 600 V VAC CIRCUIT BREAKER(690.64-705.12) =0.00974100%=0.97%AC VOLTAGE DROP OPERATING CURRENT: 5.46 A WARNING:INVERTER OUTPUT CONNECTION UCONDUITS&JUNCTION BOX(690.31)(STICKER) SHORT-CIRCUIT CURRENT: 5.89 A DO NOT RELOCATE THIS CIRCUIT BREAKER 3.VOLTAGE DROP FROM ENPHASE COMBINER TO MAXIMUM POWER: 320 W - _ WARNING:PHOTOVOLTAIC POWER SOURCE l MAIN ELECTRICAL PANEL AC DISCONNECT&PANEL(690.54) 0 PANEL(705.12)(STICKER) %Vdrop=(1.31 A•24)•(Y10 e)'(0.000778 ohms/10/(240 V) °AC DISCONNECT(690.13) •0.00204100%=0.20%AC VOLTAGE DROP 1I RATED AC OUTPUT CURRENT: 31.44 A WARNING:DUAL POWER SOURCE,SECOND SOURCE IS J PHOTOVOLTAIC AC DISCONNECT II NOMINAL OPERATING AC VOLTAGE: 240V PHOTOVOLTAIC SYSTEM TOTAL VOLTAGE DROP=0.72%•0.97%•0.20%=1.89% - 1J _. _ _ _ 421 C St,Unit 5A Epstein Residence System size:7.65 kW SINGLE LINE DIAGRAM,GRID TIED SOLAR PV SYSTEM Sun Washougal,WA 98671 15520 SW Empire Terrace (24)Panasonic VBHN32OKA03 320W Modules 5 O L A R TEL:(360)313 7190 Tigard,OR 97224 (24)Enphase IQ7X-96-2-US Micro-Inverters DATE:November 19,2019 DRAWN BY:SM CCB(OR): 198787 (541)521-7890 VOLTAGE DROP:1.89%