Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
• EMBASSY SUITES OFFICE COPY TIGARD, OR <11./G CTTY OF TIGARD REVIEWED FOR CODE COMPLIANCE SCOPE: EIFS REPAIR & ENTRY DOORS INSTALL Approve) ] OTC: [ ] Permit#: f�,,�ap )9 -. pn,'3 Address: 9� w..<�, ��c` ,. �.Suite #: Tatley Grund By: 4 y Date: J7..1)-) C1 REPAIR I RESTORE 1 RENEW Project Name: EMBASSY SUITES Applicant: TATLEY-GRUND, INC. - /" Ma CCB is: 147461 a W ' Iff . I Contact: JOEL McBROOM ■ I Phone: (503) 207-3175 , i1 ■ I Site Address: . I 9000 SW WASHINGTON SQUARE RD. I TIGARD OR, 97223 III I _ In t Map &Taxlot ID 1S126BC01500 k I i e ' '. Real Property Account#: R235560 • efrY i ., DEC10 2019 ' , ' ".' 44141440. ' ..,r 4„,,,_,t.,, . -.7 - _.....- ...... oN,...414411111r7.'4,4 y1. � CITY OF TIGARD .. ,..:. -'311f 1 ; 4.0, ,., - 3 .` " ' '1,‘g ; prayed by Planning s Date: lz%1°� l� Initials: ITY1 6 .__,. ." Sc EMBASSY SUITES TIGARD, OR SCOPE: EIFS REPLACEMENT <1111G Tatley 6rund REPAIR I RESTORE I RENEW [REMOVE AND REPLACE EIFS „00,00,0 Project Name: EMBASSY SUITES Irrijor 4110 t . Applicant: TATLEY-GRUND, INC. - - +. CCB#: 147461 $' ,:, _ �, Contact: JOEL McBROOM Phone: (503) 207-3175 4 v. Fr Site Address: s 9000 SW WASHINGTON SQUARE RD. • y TIGARD OR, 97223 ./ - Map &Taxlot ID #: 1S126BC01500 Real Property Account s: R235560 Oil J 1120 "I REPAIRED a • A ra La Outsulation® Plus MD System® EXISTING FRAMING ---,...` EXISTINGi<i"TG ' . OUTSULATION PLUS MD SYSTEM 3� £ DRWITADHESIVEINVERTICALNOTCHEDTROWEL Tatley Grund CONFIGURATION APPLIED TO BACK OF EPS i . _ EPS INSULATION BOARD NORMAL IMPACT 1: EXISTING SUBSTRATE(DENSGLASS) REPAIR I RESTORE I RENEW 6'AND ABOVE :ik; i DRYVIT WRB COATING(LIQUID APPLIED) PO Project Name: EMBASSY SUITES ll DRWIT BASE COAT _ } DRWIT REINFORCING MESH Applicant: TATLEY-GRUND, INC. 0 EMBEDDED IN DRYVIT BASE COAT CCB #: 147461 DRWIT BASE COAT in DRYVIT FINISH;; Contact: JOEL McBROOM v.11. • 't-:"I --- DRWIT DRAINAGE STRIP''ADHERED WITH DABS Phone: (503) 207-3175 :0„� - OF DRYVIT AP ADHESIVE(SEE NOTES 2 AND 3) Site Address: 9000 SW WASHINGTON SQUARE RD. EXISTING FRAMIMG TIGARD OR, 97223 DRYVIT ADHESIVE IN VERTICAL NOTCHED TROWEL CONFIGURATION APPLIED TO Map & Taxlot ID#: 1S126BC01500 - BACK OF EPS R I EPS INSULATION BOARD Real Property Account#: R235560 d _,,, AI I EXISTING SUBSTRATE I DENSGLASS I HIGH IMPACT ritt 8'AND BELOW 'AI 1DRYVIT WRB COATING(LIQUID APPLIED) pi I DRYVIT BASE COAT •i. DRYVIT PANZER REINFORCING MESH 'N 1 Al ..e. DRWIT BASE COAT 'jr II DRYVIT REINFORCING MESH gli EMBEDDED IN DRWIT BASE COAT 4.0 - DRWIT BASE COAT S7 DRYVIT FINISH ;hi: DRWIT DRAINAGE STRIP ADHERED WITH DABS OF 1 IV - DRWIT AP ADHESIVE(SEE NOTES 2 AND 3) NOTE: 1.DRWIT RECOMMENDS THAT GROUND FLOOR APPLICATIONS AND ALL FACADES EXPOSED TO ABNORMAL STRESS,HIGH TRAFFIC.OR DELIBERATE IMPACT HAVE BASE AT STANDARD NDARD M SH. CA dryvit A PANZER,MESH PRIOR TO STANDARD OR STANDARD PLUS MESH.LOCATION OF HIGH IMPACT ZONES SHOULD BE INDICATED ON CONTRACT DRAWINGS. Outsulation Plus MD System Application Instructions DS218 I. General Installation Requirements A. Project Conditions 1. Storage a. Materials shall be stored at the job site, and at all times, in a cool, dry location, out of direct sunlight, protected from weather and other sources of damage. Minimum storage temperature shall be as follows: 1) DPR, PMRTM', HDPrm, Weatherlastic'', and E FinishesT"", Color Primerm", Primus', Genesieand NCBTM': 40 °F (4 °C). <WING 2) For all other products, refer to specific product data sheets. b. Maximum storage temperature shall not exceed 100 °F (38" C). NOTE: Minimize exposure of materials to temperatures over 90 °F (32°C). Finishes exposed to temperatures over 110 °F Tatley Grand (43 °C)for even short periods may exhibit skinning, increased viscosity and should be inspected prior to use. REPAIR I RESTORE I RENEW c. Protect all products from inclement weather and direct sunlight. 2. Application a. Application of wet materials shall not take place during inclement weather unless appropriate protection is provided. Protect materials from inclement weather until they are completely dry. Project Name: EMBASSY SUITES 1)At the time of Dryvit product application, the air and wall surface temperatures shall be from 40 °F (4 `C) minimum to 100 "F (38° C) maximum for the following products: Applicant: TATLEY-GRUND, INC. a) DPR, PMR, HDP, Weatherlastic and E Finishes, Color Prime, Primus, Genesis and NCB: 40 °F (4 °C). b) For all other products, refer to specific product data sheets. CCB : 147461 3. These temperatures shall be maintained with adequate air ventilation and circulation for a minimum of 24 hours (48 hours for Weatherlastic Finishes, AmeristoneTM', TerraNeo"'and LymestoneTM')thereafter, or until the products are completely dry. Refer to published product data sheets for more specific information. Contact:JOEL McBROOM B. Inspection of Substrate 1. Acceptable substrates for application of the Dryvit Outsulation Plus MD System are listed in the Dryvit Phone: (503) 207-3175 • Outsulation Plus MD System Specification, DS137. 2. The substrate must be securely fastened per contract documents. 3. The substrate attachment method must comply with all contract documents. 4. The substrate must be clean, dry, structurally sound, free of loose material, voids, projections, hot spots, release Site Address: agents, coatings, or other materials that may affect adhesion. 9000 SW WASHINGTON SQUARE RD. 5. There shall be no planar irregularities greater than 1/4 in (6.4 mm)within any 4 ft(1.2 m) radius. TIGARD OR, 97223 6. Wood based sheathings require a 1/8 in (3.2 mm) gap between adjacent sheets per the guidelines published by the APA. C. Flashing at System Terminations Map & Taxlot ID #: 1S126BC01500 1. General a. Ensure that flashing is installed in accordance with applicable code requirements and the contract Real Property Account#: R235560 documents. As a minimum, opening preparation is required as shown in the Outsulation Plus MD System Installation Details, DS110. 2. Transition at Roof Lines a. Ensure the roof has positive drainage, i.e. all runoff shall be directed to the exterior and away from the structure. b. Roof flashing (by others) shall be installed in accordance with industry guidelines, manufacturer's instructions and contract documents. c. Runoff diverters (i.e. kickouts, crickets and saddles) (by others) shall be installed in accordance with industry guidelines, manufacturer's instructions and contract documents. Particular attention must be paid to the eaves/chimney intersections and sloped roof/wall intersections. Refer to the Dryvit Outsulation Plus MD System Installation Details, DS110. d. Hold system a minimum of 8 in (203 mm) above flat roofs; 2 in (51 mm) above sloped roofs. 3. Openings a. Heads,jambs and sills of all openings shall be prepared with Dryvit Backstop`'NTT"', AquaFlash", Flashing TapeTm or other approved flashing material selected by the design professional prior to window/door, mechanical equipment, or other component installation. For proper application, refer to the Dryvit Outsulation Plus MD System Installation Details, DS110. NOTE: Sill piece shall extend to the inside face of wall and continue a minimum of 4 in (102 mm) up at the jambs. b. Continuous flashing at heads of openings as indicated in contract documents. NOTE: For windows or doors that do not have integral flashing, a field-applied flashing shall be installed (by others) in accordance with industry guidelines,manufacturer's instructions and contract documents. Refer to the Dryvit Outsulation Plus MD System Installation Details, DS110. c. Individual windows that are ganged to make multiple units require the heads to be continuously flashed and the joints between the units to be fully sealed. Outsulation Plus MD System Application Instructions DS218 4. Decks and Patios a. Wood decks shall be properly flashed prior to system application. See the Dryvit Outsulation Plus MD System Installation Details, PS1 10. b. Verify that the system terminates above poured decks, patios, landings, etc. and that they are properly sloped and waterproofed to direct water away from the walls. 5. Utilities a. Provisions must be made to ensure that the system terminates properly at lighting fixtures, electrical outlets, hose bibs, dryer vents, etc. Refer to the Dryvit Outsulation Plus MD System Installation Details, DS 110,for general information and guidance. Tatley Grund 6. Grade Level Terminations a. Hold system a minimum of 8 in (203 mm) above finished grade. REPAIR I RESTORE I RENEW D. Sealants 1. Dryvit materials shall be completely dry prior to installation of sealant materials (typically 48 - 72 hours). Humid or cool conditions may require longer drying times. Notify the general contractor andlor architect andlor owner of all discrepancies. Do not proceed until all Project Name: EMBASSY SUITES unsatisfactory conditions have been corrected. II. Materials Required for Completing Installation of the Outsulation Plus MD System Applicant: TATLEY-GRUND, INC. A. Materials Supplied by Dryvit Systems, Inc. 1. AquaFlash and AquaFlash Mesh CCB#: 147461 2. Backstop NT— Texture, Smooth and Spray, or Backstop DMS 3. Grid TapeT" 4. Dryvit Flashing Tape and Flashing Tape Surface Conditioner Contact: JOEL McBROOM 5. AP Adhesive TM 6. Drainage Track Phone: (503) 207-3175 7. Drainage Strip TM 8. Starter StripT'& optional 9. Track -optional Site Address: 10. Genesis, Genesis DM, Genesis DMS, Primus, Primus DM, Dryflex" 9000 SW WASHINGTON SQUARE RD. 11. NCB TIGARD OR, 97223 12. Rapidry." DM 35-50, RapidryT"' DM 50-75, RapidPatchT"" 13. Standard Mesh, Standard Plus Mesh, Intermediate Mesh, Panzer°15, Panzer 20, Corner Mesh, and Detail Mesh a. It shall be colored blue for product identification bearing the Dryvit logo. Map & Taxlot ID#: 1S126BC01500 14. Dryvit Finishes 15. Dryvit Coatings and Primers Real Property Account#: R235560 NOTE: Materials listed above are those contained or referenced in the Outsulation Plus MD Specification, pS137. Typically, the project specification will identify the specific materials necessary to complete application. B. Materials Supplied by Others 1. Portland Cement: Type I or II 2. Clean Potable Water 3. Expanded Polystyrene Insulation Board meeting J51.31 END DF SECI1DN EMBASSY SUITES TIGARD, OR 1 SCOPE: ENTRY DOORS INSTALLATION <1 IT G , . Tatley Grund d REPAIR I REStORE I RENEW INSTALL (2) NEW VESTIBULE DOORS Pro ect Name: EMBASSY SUITES Applicant: TATLEY-GRUND, INC. /010 { CCB #: 147461 410 , u r Contact: JOEL McBROOM ft' . i # Phone: 5 t ( 03) 207 3175 i - — Site Address: / 9000 SW WASHINGTON SQUARE RD. P !if p ,.� I �� TIGARD OR, 97223 �r Map&Taxlot ID z: 15126BC01500 PI i siv- t �++ _ µ i — 7 Real Property Account : R235560 :::"''''''t*w'7._t,,,.4..;,:::::',.ili:,, /# it; moron, IL '-,4,.- -: • ' ''' - '''' 404s ir . ::-.T:::::!'"-°•4m7. -i.' 7:,,,......:. ii ' . �1 ' F. t ill! .. Y 4:111144,,,, . f , ,.. . ....... 1 , P� .. ,,,, i , ,_ r ..., go .... \. ".. - ..= s ,,, -, ,, ,, ,,,, .... ,,, w ry / // /lr C/ Z G/ � � 7/� / i ,�/ <TG .,., msGf - ,• ... ,. Tatley Grund ..... . REPAIR I RESTORE I RENEW `�` - �,� \` Project Name: EMBASSY SUITES j Applicant: TATLEY-GRUND, INC. I 1 CCB #: 147461 • `p Contact: JOEL McBROOM r 1 A Phone: (503) 207-3175 I _ f ( Site Address: i 9000 SW WASHINGTON SQUARE RD. • l TIGARD OR, 97223 I ,,i.. N. Map & Taxlot ID#: 15126BC01500 L---11 `' Real Property Account#: R235560 1% • OX/ 71/ 4 Vr1ttI �" P4A ' -311--- _. _ __ ____ , ..., ‘„,,,,, a _, . . , (TG . .. . • , ,,...., ...; , 4be Cr /- .!---,•/ - I 111.'' 'f Existing doors to remain and I Tatley Grand should be closed and inoperable ourng venter months Only s.de 000rs to REPAIR I RESTORE I RENEW be used • ` es- --_. .��, . ._ � --- -- \_ Project Name: EMBASSY SUITES �.__ �_ I < Remove existing Storefront frames Applicant: TATLEY-GRUND, INC. / , I entrety mciuding I transom head anC CCB #: 147461 Remove ex'isting glass Install new storefront frames f vertical jamb at entirelynd+long I ‘ each enc condt,' Contact: JOEL McBROOM ; ( transom head and Nir New motion activated single ' 1 to pnovde closure glass. Install new I siding ooars equal to Horton Phone: (503) 207-3175 vertxa+jamb at 1010 ( roSlhde Series 2003 each end condition Belt Dive)to match ex-sting to provOoe clos,,,e 1 .FIXED dark bronze aluminum frame FIXED I. .. Site Address: i tempered clear I 9000 SW WASHINGTON SQUARE RD. glass Additional anorage I TIGARD OR, 97223 anchorage of fixed leaf rs required at floor t 1111 and head conditions Use of Map &Taxlot ID #: 15326BC01500 these doors is hilted to wrter mortis. Relocate seaang to CA i Real Property Account#: R235560 allow for traffic Sow _ - s.--, • ' •N Exrstng doors shall remar and mobon senor aojusled to close doors more quickly ' durng wintor months OPTION A • EMBASSY SUITES WASHINGTON SQUARE - TGARD OR / M , i . * ' ; • ,fir? -1 CTRICAL SERVIC: OVERALL F.W.(VARIES) TRANSOM FRAM NG' T 20 VAC.60HZ.ISA OPTIONAL TOAPPLICATION: JUNCTION BOX ,r .Y ELECTRICAL ll . FIXED SIDELITE LEFT HAND, AUTOMATIC oNmAcroa, II ©�l M.I•N PRESENCE SLIDING DOOR SYSTEM. INFRARED SENSOR o d�l NOTE: DRAWING IS DIMENSIONED IN BOTH INCHES & METRIC (mm) N OPTIONAL HOLD-OPEN f l � X BEAMS CH.AT 11,0c7 / <TG • ` ` i vT ° I F 24&48"AFF a .0 4 1/2" I e m (609.6&1219.2) M/P SENSOR TatleyGrund 0 c N v. (114.3) I -o i— TYP. _-_ FIN.FLOOR ^ �� REPAIR I RESTORE I RENEW opnoNA EXTERIOR ELEVATION MUN N=TT. i O 1 II EMERGENCY �� i'II N .. - Project Name: EMBASSY SUITES KABRENviEw BPAi OUT2fM,rI(E) " ,. `,. �t0 PIAN V EW T EXTERIOR r`l' el Applicant: TATLEY-GRUND, INC. tC P ft N rY �Y OD EQUAL PANELS, (C) . M I I CCB#: 147461 \ 1/2" 2 1/4" NET OPENING, (D) / • V- I I RAIL OPTIONAL FIXED r Lo " EXTERIOR .Li Li. PANEL z r • ■ Contact: JOEL McBROOM _ w 1_ (44.5) \ a I. TEMPERED r1 �1 INTERIOR rvr ���_ GLASS I I Phone: (503) 207-3175 \ vE 0 r�_ 1 / 1 g I I I 7V �/ 0 Zii Site Address: \ PIVOT / I I / I-MOLDINGBOTTO 9000 SW WASHINGTON SQUARE RD. \N` POINT -1 2" 2 1/4" 9 _ GUDEM TIGARD OR, 97223 ,(44.5) 13/4" EXTERIOR (12.7)� � (57.2) le1::,� _ ...1 3/4" ` ` ` }.. w+ (it s1 (44.5) 1/4" -®I: V!TITI `4 . I. ' ION Map & Taxlot ID #: 1S126BC01500 1/4" , 0/ (6.4) OVERALL FRAME WIDTH, (A) (6.41 ROUGH OPENING WIDTH, (B) Real Property Account#: R235560 i 0 HORIZONTAL SECTION" ; UNIT DESCRIPTION DITEC O—SX : OVERHEAD CONCEALED FIXED SIDELITE AUTOMATIC SLIDING DOOR OPERATOR SHALL BE'DS-1B"CUL USA SINGLE SLIDE DOOR SYSTEM, NARROW STILE DOORS. APPROVED,CONFORMING TO UL STD.325&ANSI-BHMA STD.A156.10 STD. PACKAGE SHALL INCLUDE AUTOMATIC OPERATOR, FRAME AND CERTIFIED TO CAN.CSA STD.C22.2s24-93 AS MANUFACTURED By ENTREMATIC GROUP AB. DOORS WITH MUNTINS, BOTTOM RAILS WITH CONCEALED STANDARD FINISH: ANODIZED, CLEAR;DARK BRONZE; SWEEPS BRUSH-PILE WEATHER STRIPPING. EMERGENCY BREAKAWAY, SPECIAL FINISHES ARE AVAILABLE MS LOCK. GLAZING STOPS FOR TEMPERED GLASS. BOTTOM GUIDE SYSTEM IN 'J' MOLDING OF FIXED LATE, 3-POSITION ' SWITCH & MOTION/PRESENCE SENSORS ON BOTH SIDES OF UNIT. OVERALL ROUGH EQUAL NET BREAK SIZE FRAME A OPENING B PANELS C DOOR p OUT E WIDTH WIDTH WIDTH OPENING DIMN. 84" 84" 84 1/7' 41 9/16" 35 1/4" 38 7/8' (2133.6) (2146.3) (1055.7) (895.4) (987.4) +96" 96 1/7' 47 9/16" 41 1/4" 44 7/8" 96", (2438.4) (2451.1) (1208.1) (1047.8) (1139.8) 108" 108" 108 1/7' 53 9/16" 47 1/4' 50 7/8' (2743.2) (2755.9) (1360.5) (1200.2) (1292.2) KEY INCHES [B-1/2] [A+1/2] [N2-7/16r [A/2-63/4 [A/2-3 1/8] KEY( mm ) (B-12.7) (A+12.7) (A/2-11.1) (N2-171.5) (A2-79.4) IAPPLICATION: FIXED SIDELITE RIGHT HAND,AUTOMATIC SLIDING DOOR SYSTEM. NOTE: DRAWING IS DIMENSIONED IN BOTH INCHES & METRIC (mm) 7l p P <111111111G ., a M/P SENSOR NET OPENING, (D) 2 1 4" 1 2" / `� (ua.$) TYP r / / •0 (57.2)�� (12.7) FIXED I I LI* Tatley Grund PANEL • I �- 1. o o II I REPAIR I RESTORE 1 RENEW m ,;, .-, M i O n 4f I EQUAL PANELS, (C) t / N w Project Name: EMBASSY SUITES 2 1/4" 1/2'—� PIVOT / M ^+so II II liii (szz)° 1 (12.7) POINT • 0. ° me II II MUNTIN MID Applicant: TATLEY-GRUND, INC. 1 3/4' EXTERIOR 1 3/4" = v v v RAIL OPTIONAL 1/4" (44.5) (44.5) 2 W x EXTERIOR x MI = (a34 5)SQ. CCB #: 147461 I. 1/4" k S ,7 TEMPERED r'1 r� (6.4) OVERALL FRAME WIDTH, (A) (5.4� ° = GI ASS 1111 1I ROUGH OPENING WIDTH, (B) liz4,IN.TERIOR Contact: JOEL McBROOM D � 8 II II II 11 ". 0 HORIZONTAL SECTION" J-MOLDING Phone: (503) 207-3175 c BOTTOM `a v, - din GUIDE 1V J faiM i tY• Site Address: 9000 SW WASHINGTON SQUARE RD. TIGARD OR, 97223 Map &Taxlot ID#: 1S126BC01500 AUTOMATIC SLIDING DOOR OPERATOR SHALL BE "DS-18" CUL USA APPROVED, CONFORMING TO UL STD. 325& ANSI-BHMA STD. A1.56.10 Real Property Account#: R235560 CERTIFIED TO CAN. CSA STD. C22.2#24-93 AS MANUFACTURED BY P y ENTREMATIC GROUP AB. LECTRICAL SERVIC' OVERALL F.W.(vARiEs) TRANSOM FRAMING STANDARD FINISH: ANODIZED, CLEAR; DARK BRONZE; 120 VAC.60 HZ ISA OPTIONAL SPECIAL FINISHES ARE AVAILABLE TO]UNCTION BOX . ----.. .-. ... • - • onrnxrOR II ' UNIT DESCRIPTION II ®: MOTION/PRESENCE INFRARED SENSOR ��. DITEC OPTIONAL _c o ,. SX-0 : OVERHEAD CONCEALED FIXED SIDELITE HOLD-OPEN n SINGLE SUDE DOOR SYSTEM, NARROW STILE DOORS. BEAMS C/L AT m STD. PACKAGE SHALL INCLUDE AUTOMATIC OPERATOR, FRAME AND 24&48"AFF F--- t DOORS WITH MIXJTINS, BOTTOM RAILS WITH CONCEALED (609.6& 1219.2) ,Q, ij — I II m SWEEPS BRUSH—PILE WEATHER STRIPPING. EMERGENCY BREAKAWAY. MS LOCK, GLAZING STOPS FOR TEMPERED GLASS. ��I, BOTTOM GUIDE SYSTEM IN 'J' MOLDING OF FIXED LITE 3—POSITION FIN FLooR____ ___ SWITCH & MOTION/PRESENCE SENSORS ON BOTH SIDES OF UNIT. EXTERIOR ELEVATION OPTIONAL OVERALL ROUGH EQUAL NET BREAK MU. IN BAR SIZE FRAME A OPENING B PANELS C DOOR D CUT E ci WIDTH WIDTH ,WIDTH OPENING DIMN. II 84" 84 1/2" ' 41 9/16" 35 1/4" 38 7/8" ' EMERGENCY ILA p BREAXAWAr (2133.6) (2146.3) (1055.7) (895.4) (987.4) BCEdt1T DIMI'I:E) PLMJ VIEW 96"96" 96 1/2' 47 9/16" 41 1/4" 447/8" —�C 96" (2438.4) (2451.1) (1208.1) (1047.8) (1139.8) EXTERIOR 108" 108" 108 1/2" 53 9/16" 47 1/4" 50 7/8" (2743.2) (2755.9) (1360.5) (1200.2) (1292.2) KEY INCHES [8-12] [A+1/2] '[A/2-7/16j [A/2-6 3/41 [A/2-31/8] KEY'( mm ) (8.12.7) (A+12.7) (A/2-11.1)(A/2-171.5) (A/2-79.4) ENTRE .MATIC <TG , , . ,_ , , . Tatley Grund ' :' _ _�' K REPAIR I RESTORE I RENEW i ' '+.. mat ' �, Gj _-- '''- tioloiProject Name: EMBASSY SUITES ,. i ---.Z..,;` _ _...7 • € �' �` f { Applicant: TATLEY GRUND, INC. UP f CCB #: 147461 Contact: JOEL McBROOM s I , F t3 _ i..t Ake. Phone: (503) 207-3175 -;.. . 1 /1°1 i g .� " ( Site Address: Jy ! I 9000 SW WASHINGTON SQUARE RD. TIGARD OR, 97223 :- I . Ii .= � {� tr HII�.I i Map& Taxlot ID#: 1S126BC01500 `� t j f + , 3 3���S4 1 an.. - - Real Property Account#: R235560 q. `. Ditec DS18D Automc-_} c Sliding Door AVAILABLE IN: Overhead Concealed - Surface Mount - Telescopic - All Glass �h+r. nt*.,,,„,,,„; n a s A A -. 3eest.m;,4- x ,.,z.,, _ O Entrematic Group AB,2018 Ditec DS18D Automatic Ditec 0518D Motor low energy/high efficiency 75 watt Sliding Door System Standard colors aluminum and dark bronze Door opening/closing speed, time Adjustable and force settings (1, 111111111113 FEATURES& BENEFITS Open braking force &torque Adjustable Doors come in single slide, bi-part and telescopic sliders Control settings memory Up to 10 years - - High speed & smooth operation Easy installation and repair Failure detection & auto reset Yes Tatley Grand Reliable & safe operation Control board self-diagnosis Yes User-friendly control functions Break out panels with hydraulic Optional REPAIR I RESTORE I RENEW Plug & Play sensor connections closer Concealed panic bars Optional STANDARD CHARACTERISTICS Header self supporting Up to 16' Meets ANSI A156.10 guidelines for power operated pedestrian doors Carrier Wheels 4 wheels per panel Project Name: EMBASSY SUITES Certified UL/cUL Operating conditions -4 to +120 Fahrenheit Microprocessor control (-20 to +50 Celsius) Applicant: TATLEY-GRUND, INC. Automatic braking stroke adjustment Header size 4 1/2" x 7 1/2" Electro-magnetic lock system available Header fits std glass house frame Yes CCB #: 147461 Compatible with most activation devices:push button, remote control. Glass Stops 1/4'. 5/8" and 1" available motion sensors Failure alert &auto reset mode Switch 5-position rotary switch (key switch optional) Contact: JOEL McBROOM TECHNICAL SPECIFICATIONS Hinged aluminum cover self lock Yes in open position Phone: (503) 207-3175 • Fits into standard storefronts Adjustable end-stop Yes Header Height 7-1/2- 1190mm), Depth 4-1/2- (114mm) Single Sliding Systems'Ito 9'wide/91.5" high(standard) Max door weight per panel 2501bs/113kg Bi-part 10'to 14.wide/91.5" high (standard) Universal threshold Yes Site Address: Custom widths available upon request Technical data subject to change without notice. 9000 SW WASHINGTON SQUARE RD. Input Power 100v-240v AC/50-60Hz/2.5A TIGARD OR, 97223 OPTIONS s Electric solenoid locks(fail safe/fail secure) t Mg Map & Taxlot ID #: 1S126BC01500 Panic bars (recessed/surface mounted) _ • • . - Dual channel hold open beams r� Real Property Account#: R235560 Hydraulic close system (panel reset after breakout) {j�F , r Transom packages I• 11!C«-- All-Glass doors and sidelites provide added elegance and beauty to •-, "' upsca le architecture ' +s - _ _ f All colors are available i�t� g. - Cladding is an option for high end entrances :f f, _' •• •- • ' ' Battery back-up for operation in the event of power failureL? lit cc •L Ut ra .ii, Distributed By: o Entrematic USA Inc. Entrematic Canada Inc. 1900 Airport Road 221A Racco Pkwy U Monroe, NC 28110 Vaughan, ON L4J 8X9 Tel: 704-290-0980 Tel: 416-674-8880 Q Fax: 704-919-5014 Fax: 416-674-8882 Toll-Free: 866-901-4284 Toll-Free: 877-348-6837 www.ditecentrematic.us www.ditecentrematic.ca W CrL :ar,„nor El (g• a®a /p \/� ' American Association of Z c us urns /s ri Au�naticDoorMamfnchrrrrs -.. W ENTREMATIC SECTION 08460 DITEC DS18 AUTOMATIC SLIDING DOOR AING 1. GENERAL 1.01 Summary Tatley 6rund A. Work included: Furnishing and installing factory fabricated and finished Automatic sliding door system. REPAIR I RESTORE I RENEW B. Related Work: [Insert applicable section including] 1. Section 07900—Caulking 2. Section 08400— Entrances and Storefronts Project Name: EMBASSY SUITES 3. Section 08710— Finished Hardware 4. Section 08800-Glazing Applicant: TATLEY-GRUND, INC. 5. Section 12670— Entrance Mats 6. Section 16120— Electrical Supply and Termination CCB #: 147461 1.02 Submittals A. Product Data: Provide manufacturer's product and complete installation data for all materials in Contact: JOEL McBROOM this specification. B. Shop Drawings: Show profiles,joining methods, location of components, anchorage details, Phone: (503) 207-3175 adjacent construction interfacing and dimensions as well as all necessary wiring and electrical requirements. Site Address: C. Samples: Sized to adequately represent material 9000 SW WASHINGTON SQUARE RD. TIGARD OR, 97223 D. Contract Closeout: Submit the Manufacturer's warranty and performance certification (if applicable) Map&Taxlot ID #: 1S126BC01500 E. Installation Guide: Provide written installation and operating manuals and/or installation recommendations. Real Property Account#: R235560 1.03 Quality Assurance A. Installation and maintenance shall be performed by an authorized dealer and in strict compliance with the manufacturer's recommendations. B. Installing dealer shall provide factory authorized and trained service professionals 24 hours a day, seven days a week. The installing and servicing dealer shall be a certified member of AAADM (American Association of Automatic Door Manufacturers). C. ENTREMATIC Sliding Door product(s) and other products provided conform to the following codes and standards: ANSI/BHMA A156.10— Power Operated Pedestrian Doors. ANSI/UL325 — Door, Drapery, Gate, Louver and Window Operators and Systems. CUUUSA Listed —Product Safety. ASTM E283-91 Air Infiltration and ASTM E330-07 Wind Loading. AMSI Z97.1 Glazing Materials and AAMA 1303.5 Forced Entry. Entrematic Canada, Inc.: 877-348-6837, www.ditecentrematic.ca Entrematic USA, Inc.: 866-901-4284, www.ditecentrematic.us ENTREMATIC <11rG 1.04 Product Handling A. All materials shall arrive in the manufacturer's original sealed, labelled containers. B. Store materials in a dry, protected, well-vented area. Reports damaged material immediately to the delivering carrier and note such damage on the carrier's freight bill of lading. C. Remove all protective materials after installation. Tatley 6rund 1.05 Job Condition REPAIR I REBORE I RENEW A. Verify that other trades are complete before installing the automatic sliding door system. B Mounting surfaces shall be plumb, straight and secure; substrates shall be proper dimension and Project Name: EMBASSY SUITES material. Applicant: TATLEY-GRUND, INC. C. Refer to the construction documents, shop drawings and manufacturer's installation instructions. D. Coordinate installation with the glass, glazing and electrical work. CCB #: 147461 E. Observe all appropriate OSHA safety guidelines for this work. Contact: JOEL McBROOM 1.06 Warranty/Guarantee Phone: (503) 207-3175 A. Manufacturer's Standard Limited Warranty: Warranted materials shall be free of defect in material and workmanship for three years after installation. 2. PRODUCTS Site Address: 9000 SW WASHINGTON SQUARE RD. 2.01 Manufacturer: ENTREMATIC Group AB TIGARD OR, 97223 Entrematic Canada Inc. Entrematic USA Inc. 221A Racco Parkway 1900 Airport Rd Map & Taxlot ID #: 1S126BC01500 Vaughan, Ontario, L4J 8X9 Monroe, NC, 28110 Phone: 1-877-348-6837 Phone: 1-866-901-4284 Real Property Account#: R235560 2.02 Automatic Sliding Door System A. Automatic Sliding Door System: Shall be DITEC Series DS18. The system shall consist of sliding aluminum door(s) and sidelight(s) (unglazed) with security glass stops, header,jambs, DITEC digital slide system, guide threshold, actuating and safety controls. The system shall be completely engineered, manufactured and assembled by ENTREMATIC. All components shall be factory assembled in the header and tested. Field wiring consists of connection to job-site power and low voltage actuators. B. Sliding Aluminum Doors: Provide narrow stile through bolted units to dimension heights and widths with corresponding glazing as shown on order confirmation. Glass thickness may be '/:' (6mm) or%" (16mm). The door shall have an intermediate rail(s). The bi-part sliding door system shall include a two-point MS deadlock securing the lead edges of the door stiles together and to the active door carrier assembly or for single slide a one point MS deadlock securing the latch stile to the vertical lock jamb. Each door panel shall include interlocking that securely latches the swing out panel(s) to the sliding panel(s) in the fully closed position. The active sliding door shall be provided with a key cylinder on the exterior and a thumbturn on the interior. Entrematic Canada, Inc.: 877-348-6837, www.ditecentrematic.ca Entrematic USA, Inc.: 866-901-4284, www.ditecentrematic.us ENTREMATIC Breakaway (SX) panels to have top and bottom concealed pivots recessed into the extrudedIrG aluminum. C. Door Operation/ Emergency Breakaway: Shall be single slide or bi-part slide, one-way or two- way traffic. Breakaway (SX& SO) panels shall allow"breakout" (501bs max pressure ANSI/BHMAA156.10)to the full open position to provide instant egress at any point in the door's Tatley Grand movement. Door(s) and sidelight(s) shall be sized to prevent pinch point at meeting stiles. D. Aluminum Frame & Extrusions: Shall be a minimum .125" (3mm) in integral structural sections. REPAIR I RESTORE I RENEW The frame shall be 4 '/2" (114mm) deep x 1 '/"wide (44mm) section. The bi-part transom package shall contain one vertical transom tube (specify if desired). Transoms are available for V." (6mm) or 1" (24mm)glazing. Aluminum door extrusions to be narrow stile heavy wall (1/8" Project Name: EMBASSY SUITES thick)for maximum strength and maximum door opening width. All extruded aluminum to be 6063-T5. Applicant: TATLEY-GRUND, INC. E. Aluminum Extrusion Finish: Standard anodized finish shall be Clear, or Dark Bronze. Medium CCB #: 147461 Bronze, special anodized, painted and clad finishes are available upon request. Specify type and color. F. Aluminum Sidelight(s): Provide narrow stile through bolted sidelight door panel(s) to dimension Contact: JOEL McBROOM heights and widths as shown on order confirmation with corresponding glazing. Glass stops to Phone: (503) 207-3175 accommodate '/:'(6mm) or%" (16mm) glass. The door shall have intermediate rail(s). Each (SO) door panel shall include interlocking that securely latches the fully closed position. The (SO) sidelight(s) shall swing and allow instant egress at any point in the doors movement. Air infiltration and water penetration will meet or exceed ASTM E283 and ASTM E547 respectively. Site Address: 9000 SW WASHINGTON SQUARE RD. G. Header Case: Shall be 4'W wide x 7'/:" high (108 mm x 180mm) extruded aluminum. The TIGARD OR, 97223 header shall be capable of supporting a single door leaf of 300 pounds or bi-parting door leaf of 225 pounds each over a span of 16'with minimal deflection. It shall contain the DITEC digital slide system and door mounting components. The header cover shall have a continuous hinge Map & Taxlot ID#: 1S126BC01500 and open flush with the top of the header. Real Property Account#: R235560 H. Door Carrier Wheels: Shall be 2'/" (64mm) diameter urethane wheels with precision lifetime lubricated ball bearing centres. The sliding door(s) shall be held on the track by 2 Delrin anti riser blocks. The roller track shall be field replaceable. Doors can be adjusted down up to I. Guide Threshold Track: Aluminum threshold track shall be required to guide the slide panel(s) from close to open and open to close. The guide threshold track is available in the following profiles, surface double bevel; surface combination bevel/square and recessed. Options are field adjustable by snap-off bevelled edge. Surface applied track can either be full length or only below sidelight(s), leaving a clear floor in entrance. J. DITEC Digital Slide System: The drive system shall consist of an electromechanical 75W, brushless DC SPP (Standard Performance Plus) motor and enclosed hypoid gear system that offers higher speed range and faster acceleration with maximum opening speed of 750 mm/sec. Provide 120 VAC, 3 amps single-phase power supply minimum to operator. K. DS18 Ferrite Chip Control Unit: The DS18 control system shall monitor doorway holding beams, door position,electric lock position, activators, motor temperature, and condition of power. The microprocessor control shall perform on a continuous basis a self-diagnostic system check and Entrematic Canada, Inc.: 877-348-6837, www.d itecentrematic.ca Entrematic USA, Inc.: 866-901-4284, www.ditecentrematic.us ENTREMATIC shall display faults by flashing LED's and/or buzzer noise on the control panel. Torque shall be factory set as prescribed by ANSI A156.10. In the event of power failure active doors maybe opened or closed manually. (1G L. Electrical: The electrical contractor shall provide 120V AC, 60Hz Single Phase, 15Amp service to the door operator system on a separate dedicated circuit. All wiring shall be housed in a Tatley Grand separate channel raceway away from all moving parts. (Motor current draw shall be 3 amps or less for each door operator). REPAIR I RESTORE I RENEW M. Doorway Holding Beams: Doorway holding beams (optional if used with code compliant overhead sensors) shall be the factory installed at 24" (610 mm) and 48" (1219 mm)from finished floor. The beam when interrupted shall inhibit an open door from closing. Project Name: EMBASSY SUITES N. Motion Sensor: Activation device provided shall include self-contained motion/presence detector Applicant: TATLEY-GRUND, INC. mounted on each side of the door for traffic detection in each direction. Sensor uses planar K- Band to detect motion and Infrared to detect presence for safety purposes. The presence CCB #: 147461 detection feature never shuts off during the closing cycle of sliding door. The device shall be self monitoring and in physical communication with (DS18) control for door(s)to go into fail safe mode in the event of sensor failure. Sensor adjustments can be made directly or by hand held Contact: JOEL McBROOM remote control. O. Reverse on Obstruction with Safe tly Search Circuitry: The door(s) shall recycle open if an object Phone: (503) 207-3175 is encountered during the closing cycle. The circuitry shall time-out for 5 seconds then search for that object at 50% speed on the next closing cycle. If the obstruction is encountered again the door(s)will recycle open. The door(s) shall keep timing-out and recycling at 50% speed until Site Address: obstruction is cleared. If an object is encountered while opening, the door(s) will stop, reverse 9000 SW WASHINGTON SQUARE RD. direction one inch,time-out for 5 seconds and close at 50%speed. The next opening the TIGARD OR, 97223 circuitry shall search for that object at 50% speed. If the obstruction is encountered again the door(s) shall stop reverse direction one inch, time out and close. The door(s) shall continue recycling at 50% until the object is cleared. Map & Taxlot ID #: 1S126BC01500 P. Door Motion Adjustments: The DS18 control digital interface provides the means for the Real Property Account#: R235560 following door adjustments; open high speed, open low speed, open braking force, close high speed, close low speed, close braking force, opening time. Q. Accessories: The DS18 automatic sliding door package shall have the following accessories to reduce energyloss: Nylon sweep(s) on the bottom of the slidingdoor(s), double pile Y PO weather- stripping for the sliding door lead edges, single pile weather-stripping between the carrier and the header on the lead stile(s) of sidelight(s) and the pivot stile(s) of the sliding door(s). R. Options: a) Medium Stile Door panels. b) Custom height door bottom rails. c) 90 degree Limit arms in SO and SX panels. d) Program switch for daily operation. S. ACCESS CONTROL Options: a) Lock Indicator hardware. b) Hydraulic concealed door closers in SO and SX panels. Entrematic Canada, Inc.: 877-348-6837, www.ditecentrematic.ca Entrematic USA, Inc.: 866-901-4284, www.ditecentrematic.us ENTRE MATIC c) Magnetic Breakaway Latch Device. d) Battery Backup(200 cycle) power supply (concealed within header). e) Electric Lock— Fail Secure or Fail Safe configuration. <TG f) Recessed (86F) Panic device for SX panel(s). g) Keyed Multi-Function Program Switches. 2.03 OPERATING CONDITIONS Tatley Grund A. Climate Conditions: All automatic sliding door system components shall operate between—4 F (- REPAIR I RESTORE I RENEW 20C) and+120F(50C) in all climate conditions. 3. EXECUTION Project Name: EMBASSY SUITES 3.01 Inspection Applicant: TATLEY-GRUND, INC. A. Verify that the automatic sliding door system installation will not disrupt other trades. The door installer shall verify that the installation area is dry, clean and free of foreign matter. Check as- CCB#: 147461 built conditions and verify the manufacturer's automatic sliding entrance system details for accuracy to fit the wall assembly prior to fabrication. Report in writing to the Contractor any detrimental conditions to the proper functioning of the automatic sliding entrance system. Contact: JOEL McBROOM Installation shall proceed once the unsatisfactory conditions have been corrected in accordance to the manufacturer's recommendations. Phone: (503) 207-3175 3.02 Installation of Automatic Sliding Door System A. Installation shall be by an installer approved and trained by the manufacturer in strict accordance with the manufacturer's instructions and fire marshal's listing requirements. Site Address: 9000 SW WASHINGTON SQUARE RD. B. Comply with the automatic sliding door system manufacturer's recommendations and/or TIGARD OR,97223 installation guide when installing the automatic sliding entrance system. Set all units plumb, level and true. Map &Taxlot ID #: 1S126BC01500 C. Provide all fasteners required for installation of the automatic sliding door system. Real Property Account #: R235560 D. Adjustment and Cleaning: After repeated operation of the completed installation, re-adjust door operators and controls for optimum operating condition and safety. Clean all metal surfaces promptly after installation. E. Explain and review the Daily Safety Check Procedure. END OF SECTION