Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
Vgc2&19-00Y '7 ',? zo s() 8 ,q RECEIVED �.... DEC 16 2019 CITY OF TIGARD RI D BUILDING DIVISION Date: Dec 12 2019 Job: ALL STATE Ut 1 RUUD Equipment list for project: ALL STATE -Dated: Dec 12 2019 Units Tag No Model No Qty Description RGEA14: 14 SEER gas heat and electric cool residential RTU- 1 RGEA14042AJT101AA 1 packages Voltage:208-230V- 1 PH-60Hz Factory Options: None RGEA14: 14 SEER gas heat and electric cool residential RTU-2 RGEA14042AJT081AA 1 packages Voltage:208-230V- 1 PH-60Hz Factory Options: None Accessories Tag No Field Model Description RTU - 1 AXRF-FAA1 Manual Fresh Air Damper RTU -2 AXRF-FAA1 Manual Fresh Air Damper Notes Dec 122019 Performance Summary Tag: RTU -1 Model No: RGEA14042AJT101AA AHRI Ref: 7493371 Project: ALL STATE City: PORTLAND INTL ARPT State: OR Altitude: 108 Air Discharge: Downflow/Horizontal Cooling Performance AHRI Rating-Capacity: 40,000 EER: 12 SEER: 14 Gross Cap @ AHRI Rating Conditions(btuh)-Capacity:41,092 Ambient Air(F)-Dry Bulb: 87.5 Wet Bulb: 66.5 Airflow(CFM)-CFM: 1,462 SCFM: 1,462 System Entering Air(F)-Dry Bulb:80 Wet Bulb: 67 % RH: 51.1 System Leaving Air(F)-Dry Bulb:60.1 Wet Bulb: 57.8 Air Enthalpy(btu/lb)-Entering: 31.4 Leaving: 24.9 Design Net Cooling Capacity(btuh)-Total: 42,800 Sensible: 31,400 Latent: 11,400 Design Gross Capacity(btuh)-Capacity: 44,700 Sensible: 33,300 Total Power-Watts: 3,286.5 KW:3.3 Heating Performance Gas Heating Values(btuh)-Input: 100,000 Output: 81,000 Heating Airflow(CFM)-CFM: 1,462 Air Dry Bulb (F)-Outdoor: 29.5 Entering Air:70 Leaving Air: 121.3 Air Temperature Rise (F)-Rise: 51.3 Air Moving System Characteristics External Static Pressure (inches WG)-ESP: 0.5 Blower Speed or Speed Tap-Tap: Next Higher Drive: Direct Motor Characteristic(watts& BHP)-Power: 538.2 Electrical Supply Power Supply(Volt/Hz/Ph)-Volt/Hz/Ph: 208-230160/1 Minimum Ampacity(amps)-Ampacity: 30 Max Overcurrent Protection (amps)-Fuse: 45 HACR Breaker: 45 Dimensions, Weight & Clearances Dimensions-Length: 52 -7/16 Width: 47 -1/2 Height: 41 Weight(lb)-Weight: 446 Clearances(inches)-Front: 48 Cond. Coil: 18 Duct Side: 12 Clearances(inches)-Evap End: 36 Top: 60 411111111,....o Product Submittal#: 5ad192f2-cbce-437a-826c-a772a2724123 RUUD Submittal Printed on: 12/12/2019 7:01:22 PM 0"^"■1111111, For Model: RGEA14042AJT101AA In keeping with its policy of continous progress and product improvement,reserves the right to make changes without notice. Gross capacity does not include the effect of motor heat.AHRI rating is net capacity and includes the effect of fan motor heat.All net capacities also accounts for the effect of motor heat. ASHRAE Weather Data©2009 American Society of Heating,Refrigerating and Air-Conditioning Engineers,Inc.,Atlanta,GA,USA.www.ashrae.org All rights reserved.Used by permission in this program. Model: RGEA14042AJT101 AA "r. ' TOP VIEW _ BOTTOM ,mg., Mir iM9E VIEW 11 11111 I BOTTOM RETURN ��� PM") OPEN1Vcs 1 1v s`i DUCT EJJ ' OPENING �J]YJ1' OUTDOOR FAN GRILLE& ^+'1—1 �a^i COIAPRESsORACCESS i [ I Designates Metric Conversions „'i;q FEATURES 1. All models feature Scroll®compressors for maximum 10. Inside the easily accessible furnace compartment is the efficiency and quiet operation.5 Ton RGEA15 models draft inducer motor.This motor is specially designed for feature UltraTech'Scroll 2-Stage compressors with quiet reliable operation.In addition to the draft inducer Comfort Alert`"diagnostics(see below),high/low pressure motor,the in-shot gas burners and manifold efficiently switches,and hard start kits. regulate the flow of gas for combustion.These new 2. Louvered condenser compartment for protecting the coil gas/electric units also feature direct-spark ignition and against yard hazards and/or weather extremes, remote flame sensors for added reliability and efficiency. 3. One-piece top with a deep flange to help keep water out 11. All units feature an internal trap on the condensate line of the unit. eliminating the need for installing an on-site external trap. 4. Supply and return air openings feature a one-inch tall 12. Easily accessible control box. flange to prevent water migration into the ductwork. 13. Single point wiring simplifies installation. 5. Access panels have"weep holes"and channels to further 14. Our gas/electric package units feature a tubular heat help manage water run-off. exchanger design.Tubular heat exchangers are more 6. Side and down discharge options available on all models. efficient and durable than older-style clamshell heat All models are shipped ready for horizontal application. exchangers. 7. Easily accessible blower section complete with slide-out 15.Thermal expansion valve standard on all models for blower.The RGEA15 comes standard with variable speed superior superheat control,reliability,and energy motor with adjustable airflow in heating and cooling.The efficiency at all operating conditions. variable speed motor also comes with a interface that 16. Filter drier standard on all models(not shown). allows for dehumidification when used in continuous 17. Rugged baserail included for improved installation and humidistat.The variable speed system is capable of 1 handling inch external static. 18. Complete factory charged,wired and run tested. 8. Refrigerant connections are conveniently located for easy 19. Molded compressor plugs. service diagnostics. 9. Condenser and evaporator coils feature enhanced fins for better heat transfer and rifled copper tubing for greater efficiency. FIELD INSTALLED ACCESSORIES Roof Curb(8"[2032 mmj, 14"[355.6 mmj Low Pressure Control 0 &24" [609.6 mm]High Full Platform) ❑ Economizer(Enthalpy Controlled)Downflow Only 0 Roof Curb(14" [355.6 mm&24"[609.6 mm] Manual Fresh Air Damper 0 Sloped Platform) ❑ L.P.(Propane) Kit 0 Filter Accessory ❑ Transition(Rectangular-Round)Downflow/Sideflow 0 Lift Kit(For Rigging) 0 Concentric Diffuser and Grille 0 Time Delay Relay 0 High Pressure Control 0 Start Assist 0 Thermostat 0 Low Ambient Control ❑ Before proceeding with installation,refer to installation instructions packaged with each model,as well as complying with all Federal,State,Provincial,and heem les Company,Inc. Local codes,regulations,and practices. P.O.Box 17010,Fort Smith,AR 72917 "In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice." PRINTED IN U.S.A. 5-16 OG FORM NO.X33-1565 AXRF-FAA1 - Manual Fresh Air Damper FRESH AIR DAMPER AXRF-FAA1 (Fixed-0-35%) The 0-35% manual outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required.The amount of outside air(0-35%)is controlled by sim-ply adjusting the side damper. AXRF-FAB1 (Motorized-0-35%) The 0-35% motorized outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required. The control motor opens the adjustable slide damper when the unit blower motor is energized. '1F..i 4i ..." .."-•,---, CAULK INSIDE OF CORNERSNI - jj�i (TYP.4 PLACES)(334112)MATERIALi!e: ,„.. ..,. , �/. \ .,- --.. [t9 mm) j � , \� „, 204z" ..„ 1521 mm] /, SHIP HOOD REMOVED ���� - `�/ 15'/e" C/// j ,. / [3 84 mm] / - " - (304101)GASKET le"pie mm)x /a" 12.7 mmj I e/a"[15.87 mmj FLANGE ON BACK SIDE 1349 mm),)\, \ 12" -- 1305 mm] Dec 12 2019 Performance Summary Tag: RTU -2 Model No: RGEA14042AJT0B1AA AHRI Ref: 7493371 Project: ALL STATE City: PORTLAND INTL ARPT State: OR Altitude: 108 Air Discharge: Downflow/Horizontal Cooling Performance AHRI Rating-Capacity: 40,000 EER: 12 SEER: 14 Gross Cap @ AHRI Rating Conditions(btuh)-Capacity: 41,092 Ambient Air(F)-Dry Bulb: 87.5 Wet Bulb:66.5 Airflow(CFM)-CFM: 1,462 SCFM: 1,462 System Entering Air(F)-Dry Bulb: 80 Wet Bulb: 67 % RH: 51.1 System Leaving Air(F)-Dry Bulb: 60.1 Wet Bulb: 57.8 Air Enthalpy(btu/lb)-Entering:31.4 Leaving: 24.9 Design Net Cooling Capacity(btuh) -Total: 42,800 Sensible: 31,400 Latent: 11,400 Design Gross Capacity(btuh)-Capacity: 44,700 Sensible: 33,300 Total Power-Watts: 3,286.5 KW: 3.3 Heating Performance Gas Heating Values(btuh)-Input:80,000 Output: 65,000 Heating Airflow(CFM)-CFM: 1,462 Air Dry Bulb(F)-Outdoor:29.5 Entering Air: 70 Leaving Air: 111.2 Air Temperature Rise(F)-Rise: 41.2 Air Moving System Characteristics External Static Pressure(inches WG)-ESP: 0.5 Blower Speed or Speed Tap-Tap: Next Higher Drive: Direct Motor Characteristic(watts& BHP)-Power: 538.2 Electrical Supply Power Supply(Volt/Hz/Ph)-Volt/Hz/Ph: 208-230/60/1 Minimum Ampacity(amps) -Ampacity:30 Max Overcurrent Protection (amps) -Fuse: 45 HACR Breaker: 45 Dimensions, Weight & Clearances • Dimensions-Length: 52-7116 Width: 47 -1/2 Height: 41 Weight(lb)-Weight: 441 Clearances (inches)-Front:48 Cond.Coil: 18 Duct Side: 12 Clearances(inches)-Evap End:36 Top:60 41111111118mmo_ Product Submittal#: 667130b2-bcc8-472d-b22d-855a94d26c2c RUUD Submittal Printed on: 12/12/2019 7:01:22 PM 11"""•11111., For Model: RGEA14042AJT081AA In keeping with its policy of continous progress and product improvement,reserves the right to make changes without notice. Gross capacity does not include the effect of motor heat.AHRI ratings net capacity and includes the effect of fan motor heat.All net capacities also accounts for the effect of motor heat ASHRAE Weather Data®2009 American Society of Heating,Refrigerating and Air-Conditioning Engineers,Inc.,Atlanta,GA,USA.www.ashrae.org All rights reserved.Used by permission in this program. Model: RGEA14042AJT081AA "�F"' TOP VIEW .,. I BOTTOM t } VIEW i soTrou I RE1uRN DUCT , OPFINe , m. / ._��v Isve.nl P++vnl M1 1I till Illil/4 :� �,0 -- — -- BOTTOM \ i ��>- It I f J1JL1 GRILLS OR FAN aw I �r a'I COMPRESSOR ItCCESS [ ]Designates Metric Conversions Iisr FEATURES 1. All models feature Scroll®compressors for maximum 10. Inside the easily accessible furnace compartment is the efficiency and quiet operation.5 Ton RGEA15 models draft inducer motor.This motor is specially designed for feature UltraTech"Scroll 2-Stage compressors with quiet reliable operation.In addition to the draft inducer Comfort AIertr'diagnostics(see below),high/low pressure motor,the in-shot gas burners and manifold efficiently switches,and hard start kits. regulate the flow of gas for combustion.These new 2. Louvered condenser compartment for protecting the coil gas/electric units also feature direct-spark ignition and against yard hazards and/or weather extremes. remote flame sensors for added reliability and efficiency. 3. One-piece top with a deep flange to help keep water out 11. All units feature an internal trap on the condensate line of the unit. eliminating the need for installing an on-site external trap. 4. Supply and return air openings feature a one-inch tall 12. Easily accessible control box. flange to prevent water migration into the ductwork. 13. Single point wiring simplifies installation. 5. Access panels have"weep holes"and channels to further 14. Our gas/electric package units feature a tubular heat help manage water run-off. exchanger design.Tubular heat exchangers are more 6. Side and down discharge options available on all models. efficient and durable than older-style clamshell heat All models are shipped ready for horizontal application. exchangers. 7. Easily accessible blower section complete with slide-out 15.Thermal expansion valve standard on all models for blower.The RGEA15 comes standard with variable speed superior superheat control,reliability,and energy motor with adjustable airflow in heating and cooling.The efficiency at all operating conditions. variable speed motor also comes with a interface that 16. Filter drier standard on all models(not shown). allows for dehumidification when used in continuous 17. Rugged baserail included for improved installation and humidistat.The variable speed system is capable of 1 handling inch external static. 18. Complete factory charged,wired and run tested. 8. Refrigerant connections are conveniently located for easy 19. Molded compressor plugs. service diagnostics. 9. Condenser and evaporator coils feature enhanced fins for better heat transfer and rifled copper tubing for greater efficiency. FIELD INSTALLED ACCESSORIES Roof Curb(8"[203.2 mm],14"[355.6 mm] Low Pressure Control ❑ &24"[609.6 mm]High Full Platform) ❑ Economizer(Enthalpy Controlled)Downflow Only ❑ Roof Curb(14"[355.6 mm&24"[609.6 mm] Manual Fresh Air Damper 0 Sloped Platform) ❑ L.P.(Propane)Kit ❑ Filter Accessory 0 Transition(Rectangular-Round)Downflow/Sideflow 0 Lift Kit(For Rigging) ❑ Concentric Diffuser and Grille 0 Time Delay Relay ❑ High Pressure Control ❑ Start Assist ❑ Thermostat ❑ Low Ambient Control ❑ Before proceeding with installation,refer to installation instructions packaged with each model,as well as complying with all Federal,State,Provincial,and Local codes,regulations,and practices. Rheem Sales Company,Inc. P.O.Box lees Fort Smith,.AR 72017 "In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice." PRINTED IN U.S.A. 5-16 00 FORM NO.X33-1565 , AXRF-FAA1 - Manual Fresh Air Damper FRESH AIR DAMPER AXRF-FAA1 (Fixad-0-35%) The 0-35% manual outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required.The amount of outside air(0-35%)is controlled by sim-ply adjusting the side damper. AXRF-FAB1 (Motorized-0-35%) The 0-35% motorized outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required. The control motor opens the adjustable slide damper when the unit blower motor is energized. �ee rs Ala�.. °"kkt F 10h. "i r % CAULK INSIDE OF CORNERS I (TYP.4 PLACES)(304112)MATERIAL ��j/, - \ .--''''. .... 440 '— [521 mm) SHIP HOOD REMOVED ��� -" ,/� \�r/ 15Ve" / - 15mm] /,• j (304101)GASKET Ye"[3.18 mm]x V2"112.7 mm] � '� '� W [15.87 mm]FLANGE ON BACK SIDE 133ta" ..,,`.� .,'� [349 mm)- �� l'� �' 12" [305 min]