Report Mut 7577 Sc✓Rib C� MiTek® MiTek USA, Inc. 250 Klug Circle Corona,Ca.92880 Telephone 951/245-9525 Fax 951/273-0040 January 30, 2020 To Whom It May Concern Re: End Jack Top Chord over Hip Truss Top Chord Shim note. In regards to the above mentioned subject the engineering note on the End Jack trusses referring to "Beveled plate or shim required to provide full bearing surface with truss chord at joint(s) ( )." Does not require a shim, provided the Roof Live Load (Roof Snow included) is less than or equal to 40 psf. This is referring to the top chord bearing condition at End Jack trusses bearing on the Hip Truss flat top chord. An acceptable condition would provide support where indicated and connection by others or(2)-16d common wire (0.162" dia. x 3.5" long)Toe-Nails at each End Jack top chord to Hip Truss top chord, not to exceed 4' on center along the extension of the End Jack top chord. This is considered a Mechanical Connection. Maximum uplift not to exceed 170 lbs. Anchor hardware required for uplift exceeding 170 lbs. If you have any questions regarding this matter, please feel free to contact me. Very truly yours, David Baxter, P.E., S.E. Chief Engineer tD PR046, s MiTek USA �,1r t �5 �NGINEF ip2 ��04 wnsYc �n� 9200 9r DB oryyL OREGON 1« �<v 51398 '; <O Ik14 20 P+ �S.GIS ER�0 01/30/2020 MFRRIt -' 1/30/2020 ONAL RENEWAL DATE:12-31-2021