Plans (2) Portland,Oregon VISTA Kansas City,Missouri lilt gni —STRUCTURAL.— February 12,2020 OFFICE COPY t cd ILA" i Mountainwood Homes FEB 19 Z020 8324 SW Nimbus Ave. Beaverton,OR 97008 Approved plans GI l E�iE shall be on job site. - l lLO -� R Re:McGinnis Remodel Bearing Wall Structural Letter: Vista Structural Engineering,LLC was asked to evaluate the change in load path due to a new internal door opening and header addition to a bearing wall for the above referenced project.Field verification shows that the bearing wall of interest supports three roof trusses above.The new header calculations are shown below to confirm the 4x8 header used for the door opening is of sufficient size to support the roof trusses above.Although the addition of an opening with a header will change the load path to the floor below,the loading and stresses on the structure below will not increase.In fact,the load on the structure below will decrease due to the removal of 4'-0"of wall at this location.Therefore,no structural upgrade is required to the structure below. Our firm appreciates the opportunity to serve you. If you have any questions or if you need anything further, please feel free to contact us. Sincerely, LIABILITY VALIDITY OF PERMIT Vista Structural Engineering,LLC THE ISSUANCE OF A PERMIT The City of Tigard and its BASED ON CONSTRUCTION employees shall not be DOCUMENTS AND OTHER responsible for discrepancies DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM Which may appear herein. REQUIRING THE CORRECTION Dennis Heier,P.E. OF ERRORS.ORSC 105.4 Ito �G �c PROF CITY OF TIGARD 0� � INk s Rio REVIEWED FOR ODE COMPLIANCE sans Approved: I OTC: j I OREGON Permit Ih �"C2O � `kiffrmr4M1 31 e Address: er5pvi � Qri)-14- 02/ Suite#: gy: Dates 2% ' ► EXPIRES:8/3OI2021 VISTA STRUCTURAL ENGINEERING, LLC 14718 NW DELIA STREET PHONE: 971.645.0901 PORTLAND, OREGON 97229 - 1 - VISTASTRUCTURAL.COM Title Block Line 1 Project Title: You can change this area Engineer: using the"Settings"menu item Project ID: and then using the"Printing& Project Descr: Title Block"selection. Title Block Line 6 Printed 12 FEB 2020,12 40PM Wood Beam File=C:IUsers1ERICST-11DROPBO-11VISTAJ-11MOUNTA-11MCGINN-11CALCUL-114x10Header.ec6 . Software copyright ENERCALC,INC.1983-2019,Build:12.19.12.31 . Lic.#:KW-06010523 Vista Structural Engineering,LLC DESCRIPTION: NEW HEADER BETWEEN BEDROOMS CODE REFERENCES Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10 Load Combination Set:ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb+ 1,000.0 psi E:Modulus of Elasticity Load Combination ASCE 7-16 Fb- 1,000.0 psi Ebend-xx 1,300.Oksi Fc-Prll 1,000.0 psi Eminbend-xx 1,300.0ksi Wood Species : Fc-Perp 1,000.0 psi Wood Grade : Fv 65.0 psi Ft 65.0 psi Density 34.0pcf Beam Bracing : Beam is Fully Braced against lateral-torsional buckling b b D(0.075)bS(0 125) t --a ,4� 4x8 rA Span=4.0 ft � Applied Loads Service loads entered.Load Factors will be applied for calculations. Uniform Load: D=0.0750, S=0.1250, Tributary Width=1.0 ft,(Roof) DESIGN SUMMARY Design OK Maximum Bending Stress Ratio = 0.136 1 Maximum Shear Stress Ratio = 0.222 : 1 Section used for this span 4x8 Section used for this span 4x8 = 156.55psi = 16.57 psi = 1,150.00psi = 74.75 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 2.000ft Location of maximum on span = 3.401 ft Span#where maximum occurs = Span#1 Span#where maximum occurs = Span#1 Maximum Deflection Max Downward Transient Deflection 0.005 in Ratio= 9576>=360 Max Upward Transient Deflection 0.000 in Ratio= 0<360 Max Downward Total Deflection 0.008 in Ratio= 5985>=180 Max Upward Total Deflection 0.000 in Ratio= 0<180 Maximum Forces &Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values _ Shear Values Segment Length Span# M V Cd C FN C i Cr Cm C t C L M fb F'b V fv F'v D Only 0.00 0.00 0.00 0.00 Length=4.0 ft 1 0.065 0.106 0.90 1.000 1.00 1.00 1.00 1.00 1.00 0.15 58.71 900.00 0.11 6.21 58.50 +D+S 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=4.0 ft 1 0.136 0.222 1.15 1.000 1.00 1.00 1.00 1.00 1.00 0.40 156.55 1150.00 0.28 16.57 74.75 +D+0.750S 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=4.0 ft 1 0.115 0.187 1.15 1.000 1.00 1.00 1.00 1.00 1.00 0.34 132.09 1150.00 0.24 13.98 74.75 +0.60D 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length=4.0 ft 1 0.022 0.036 1.60 1.000 1.00 1.00 1.00 1.00 1.00 0.09 35.22 1600.00 0.06 3.73 104.00 Overall Maximum Deflections Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl Location in Span +D+S 1 0.0080 2.015 0.0000 0.000 Title Block Line 1 Project Title: You can change this area Engineer: using the"Settings"menu item Project ID: and then using the Printing& Project Descr: Title Block"selection. Title Block Line 6 Printed:12 FEB 2020,12:40PM Wood Beam File=C:\UsersIERICST-11DROPBO-11VISTAJ-11MOUNTA-11MCGINN-11CALCUL-114x10Header.ec6 . Software copyright ENERCALC,INC.1983-2019,Build:12.19.12.31 . Lic.#:KW-06010523 Vista Structural Engineering,LLC DESCRIPTION: --None-- Vertical Reactions Support notation:Far left is#1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.400 0.400 Overall MINimum 0.250 0.250 D Only 0.150 0.150 +D+S 0.400 0.400 +D+0.7505 0.338 0.338 +0.60D 0.090 0.090 S Only 0.250 0.250