Plans ` VALIDITY OF PERMIT 1FFICE COPY THE ISSUANCE OFA PERMIT Photovoltaic Installation Electrical Diagram 7!� p, - Look Residence BASED ON CONSTRUCTION DOCU ►T r► a • _ R _ ... RAT- t Mild ErnMI iii L __ i '1' �E • '•'S. •RSC 105.4 77 ,, I0r, ... y0 y ,,, pep 1._.. .. ____ ._ . .., . a, , . `_ H CITY OF TIGA1tD • REVIEWED FOftti, LDE COMPLIANCE IApproved: I 00 2 Strings of 14 Modules. DC Voltage Drop: ( [i;: [ ..., ` .0 28 SolarEdge P400 Optimizers A maximum distance of 562 feet will limit the voltage drop to 2%or less with a#10 copper Permit conductor delivering 15 amps on a 840 volt system ''• 1 J �� \! /� r (60 Vmp x 14 modules=840). I d E.(rc!^+s: 1.66 T./V •rI3 i�}-V�r LIABILITY30.0 Amps Rated ampacity of selected conductor ! ' f 1.14 Ohms Resistance(Ohms per 1000 feet) S.'; 1 t C: It: The City of Tigard and its 0.05 Ohms Reactance(Ohms per 1000 feet) employees shall not b 8.84 volts maximum allowable voltage drop at2% Bjy: , �� Date: � �)l� 0.9 Power Factor 4 ffffllll 1111 LC� responsible for discrepan ies AC Voltage Drop: i /' /0 A maximum distance of 119 feet will limit the - - which may pgar herei . voltage drop to 2%or less with a#8 Copper r ge conductor delivering 32 amps on a 240 volt , SE7600H-US(240)Inverter system. 1 GFP 1 40.0 Amps Rated ampacity of selected conductor �� eoov A oc 0.7421 Ohms Resistance(Ohms per 1000 feet) 2P 40A Breaker 0�� \� 0.052 Ohms Reactance(Ohms per 1000 feet) 0 Internal 4.8 volts maximum allowable voltage drop at 2% DC 0.9 Power Factor y �\ �\i Disconnect 0E L1,L2,N#8 THHN in Li,L2,N#8 THHN in 5' %"PVC 5'of a"PVC Approved plans 200A Main Panel 2 Positive,2 Negative and Ground Ground THHN,USE-2 \ shall be on job site. In 60'of 3:"EMr ^Q Inverter Specifications: Specifications: Ground#10 THHN Panasonic 320 VBHN320KA03 SolarEdge SE7600H-US 60A AC Disconnect Pmax: 320 Watts Compliance:UL-1741 `` Vmpp: 58.7 V Max DC Input Voltage: 480VDC J Voc: 70.5 V Max DC Input Current: 20 Amps Contractor Customer !mop: 5.46 A Max AC Output Power:7600 Watts Nathaniel Look Single Line Is cp 5.89 A OutputP g Max Current: 32 Amps Premier Solar NW Nominal Volta e:240 VAC PREMIER SOLAR 12399 NW Waker Dr. 15080 SW 93rd Ave. Max Series Fuse:15A 9 Tigard OR.97224 Max System Voltage:600V Portland, Or. 97229 January 30, 2020 Dimensions:62.6"x41.5"x1.57" NORTHWEST 503 349-1366 Weight:40.81 lbs. Look Site Plan Roof Structure&Site Map ADJACENT PROPERTY i 1 / 22 IIIII v_ __--- 21' n 3it ----- ,A 11 1.I II'I�, x �I LL� N � 1 D / , .'"'".''''."''''''. ' O •'� m ry ................111111111111 0 A m b O .�� a v D m 70 \\\\V . a X o .. 1 T 15 ro s c O iu 10' la" I / � ADJACENT PROPERTY 110' H Contractor: Customer: f 44,.... �► GENERAL CONTRACTOR: C&B RENEWABLE ENERGY,LLC Nathaniel Look 1239P R.E M I E R PORT NWAN WAR R,9 DR229 15080 Tigard SW 93rd Ave. Wig SOLAR PORTLAND OR.,97229 Tigard OR.97224 ofr � .>��}� ��.�. 503828-9500 503349-1366 Plot Map January 30,2020 CONTACT:CLIFF BARRY Legend: =Sun Eye Reading Location Look Residence Scale 3/32" = 1" 1 . 56' o... -4.- No Less Than 12"From Ridge ,..., (28) Panasonic 320W ,./ .,, . I Modules ...... w/(1) SolarEdge SE7600H-US Inverter / . . .. .... . ...... . 5!----`-12' ,iiii ,//// , ..A._..._ 4 . *'N*.‘ - IF ----,„. NN ... ‘N , . ,--- „ , \AC 200A Service Inverter ‘4*' Utility Meter ' 0 Disconnect r.. ' Panel , 1 Roof Mounting Datail: Mounting Notes 1. Eng. Trusses @ 24" O.C. 2. Roof penetrations: 24-48" O.C. So\a Modu\e 3. Composition Roofing 4. Panel height off roof< 18 inches 5. Weight of PV modules and assembly `` less than 4.5 lbs per sq. ft. � , 6. Azimuth: 90° Ironrid 7. Module Tilt: 21-o e XR100 Rail g 8. Integrated Grounding Hardware 6 inches 9. All installations comply with positiarvRtrofin manufacturer's installation instructions 10. All horizontal ridges kept clear of PV components at least 1 ft. either side 11. PV array to cover less than 25% of total roof area g 12. Solar Code 305.4#3.2: Attachments En .Trusses shall be spaced no greater than 24" O.C. in at 24"OC any direction when located within 36" of a roof edge, hip, eave, or ridge. 5/16"X6"SS Hanger Bolt 13. Solar array not to exceed height of any 3" Lag thread for 2.7"Thread horizontal ridge line. penetration in to roofing member Total Roof Area: 3,410 sq. ft. January 30,2020 Total Solar Area: 539 sq. ft. Solar Covers 16% of Roof Area Nathaniel Look EQUIPMENT 15080 SW 93rd Ave. Tigard OR.97224 (28) Panasonic 320 503 349-1366 VBHN320KAO3Modules ----- -------- a GENERAL CONTRACTOR: / (1)SolarEdge SE7600H US Inverter C&B RENEWABLE ENERGY,LLC 12399 NW WAKER DR. Iron Ridge Mounting System PORTLAND OR.,97229 503 828-9500 PREMIER SOLAR CONTACT:CLIFF BARRY Aluminum PV Roof Flashings ORTi:.-HWES f'