Loading...
Report FfS2ozo- )(7 .• . . WYAT T FIRE PROTECTION , INC. 9095 S.W. Burnham Tigard, OR 97223 PROAMPAC DENSITY UPGRADE 7400 SW LANDMARK LN TIGARD, OR 97224 PROFFS GN s �F v� 2089P yt N ! ,� MAY20,19?) O�/,qN C. [Jan 31,2020 EXPIRES: 12/31/2020 FIRE PROTECTION EQUIPMENT SUBMITTAL t CQ I Fire & Building Products CENTRAL Customer Service/Sales: Technical Services:Tel: (800)381-9312/Fax: (800)791-5500 Tel:(215)362-0700/(800)523-6512 Fax:(215)362-5385 Series ELO-231B — 11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage sentative of all possible corrosive at- General mospheres.Consequently,it is recom- mended that the end user be consulted Description with respect to the suitability of these corrosion resistant coatings for any The 11.2 K-factor, Series ELO-231B, given corrosive environment. The ef- # Standard Response, Standard Cover- fects of ambient temperature, concen- age, Upright and Pendent Sprinklers tration of chemicals,and gas/chemical (Ref. Figure 1) are automatic sprin- velocity, should be considered, as a klers of the frangible bulb type. They minimum, along with the corrosive na- are "standard response - spray sprin- ture of the chemical to which the sprin- . ' klers" that produce a hemispherical klers will be exposed. water distribution pattern below the P g deflector. An upright intermediate level version of the Series ELO-231B Sprinklers for The 11.2 K-factor, ELO-231B Sprin- in-rack applications can be obtained klers were subjected to full scale,high- by utilizing the Series ELO-231B Up- piled storage, fire tests to qualify their right Sprinkler with the WSG-2 Guard • use in lieu of 5.6 or 8.0 K-factor stand- & Shield, and a pendent intermediate and spray sprinklers for the protection level version of the Series ELO-231B of high-piled storage. Sprinklers can be obtained by utiliz- Higher flow rates can be achieved at ing the Series ELO-231B Pendent 4 1, much lower pressures with the 11.2 Sprinkler with the WS-2 Shield. If there K-factor, ELO-231B Sprinklers — is a possibility of the pendent interme- making their use highly advantageous diate level version being exposed to in high density applications, such as mechanical damage, a G-2 Guard can the protection of high-piled storage. be added. Wax or lead coatings can be used to WARNINGS extend the life of the copper alloy com- The 11.2 K-factor, Series ELO-231B ponents used in Series ELO-231B Upright and Pendent Sprinklers de- ,t„ sprinklers beyond that which would scribed herein must be installed and otherwise be obtained when exposed maintained in compliance with this to corrosive atmospheres. Although document, as well as with the applica- wax, lead,and polyester coated sprin- ble standards of the National Fire Pro- klers have passed the standard corro- tection Association, in addition to the sion tests of the applicable approval standards of any other authorities hav- agencies, the testing is not repre- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- IMPORTANT ing their fire protection system and de- Always refer to Technical Data vices in proper operating condition. Sheet TFP700 for the "INSTALLER The installing contractor or manufac- WARNING" that provides cautions turer should be contacted with any with respect to handling and instal- questions. lation of sprinkler systems and com- ponents. Improper handling and in Installation of Series ELO-2318 Pen- stallation can permanently damage dent Sprinklers in recessed escutch- a sprinkler system or its compo- will void all sprinkler warranties, nents and cause the sprinkler to fail as well as possibly void the sprinkler's to operate in a fire situation or cause Approvals and/or Listings. it to operate prematurely. Page 1 of 6 MARCH, 2007 TFP342 Page 2 of 6 TFP342 SPRINKLER FINISH TYPE TEMPERATURE BULB NATURAL CHROME LEAD WAX WAX LIQUID BRASS PLATED COATED COATED OVER LEAD UPRIGHT 155°F/68°C Red 3 (TY5151 200°F/93°C Green & 1,2,3,4 TY5851) 286°F/141°C Blue 3 3(a) 155°F/68°C Red 3 PENDENT 200°F/93°C Green (TY5251 1,2,3,4 286°F/141°C Blue 3 3(a) NOTES: 1. Listed by Underwriters Laboratories, Inc. (UL Listed). 2. Listed by Underwriters Laboratories, Inc.for use in Canada(C-UL Listed). 3. Approved by Factory Mutual Research Corporation(FM Approved). 4. Approved by the City of New York under MEA 291-04-E. (a). FM Approved for a maximum ceiling temperature of 150°F/66°C. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K-FACTOR SERIES ELO-231B UPRIGHT AND PENDENT SPRINKLERS (Refer to the Design Criteria Section) Model/Sprinkler Technical Design Criteria Identification Data UL and C-UL Listing NumbersApprovalsRequirements The 11.2 K-factor, Model ELO-231 B UL and C-UL Listed. FM and NYC Ap- (TY5151, TY5251 & TY5851) Sprin- TY5151 - Upright 11.2K, 3/4"NPT proved.(Refer to Table A for complete klers are to be installed in accordance TY5251 - Pendent 11.2K, 3/4"NPT approval information including corro with NFPA 13 standard sprinkler posi- TY5851 - Upright 11.2K, 1/2"NPT sion resistant status. The approvals tion and area/density flow calculation TY5151 is a redesignation for C5151. apply to the service conditions indi requirements for light, ordinary, or ex- cated in the Design Criteria section.) tra hazard occupancies, as well as TY5251 is a redesignation for C5251, Maximum Working Pressure high piled storage occupancies (solid G1871, and S2531. 175 psi (12,1 bar) piled,palletized,rack storage,bin box, TY5851 is a redesignation for C5851. Discharge Coefficient and shelf storage including but not lim- K= 11.2 GPM/psi1i2 ited to Class I-IV and Group A plastics) (161,4 LPM/bar1i2) with a minimum residual (flowing) pressure of 7 psi (0,5 bar) for wet or Temperature Ratings dry pipe systems. Refer to Table A Finishes FM Approval Refer to Table A Requirements Physical Characteristics The 11.2 K-factor, Model ELO-231B P hysiBronze (TY5151, TY5251 & TY5851) Sprin- FrameCap Bronze klers are to be installed in accordance Assembly with the applicable"control mode den- Sealing Nickel w/Teflont sity/area" guidelines provided by Fac- BerylliumBulb (5 mm die.) Glass tory Mutual. (FM guidelines may differ Compression Screw Bronze from UL and C-UL Listing criteria.) Deflector Bronze t Registered trademark of DuPont. TFP342 Page 3 of 6 *Temperature rating is indicated on deflector. **Pipe thread connections per ISO 7/1 can be provided on 1/2"(12,7 mm) special request. [NOMINAL MAKE-IN 3/4"** 7 i • 1 _ NPT • Components: /// rl�T // \R, III 'I 2 4 �\ 1 Frame 2-13/16" 1) 3 nk,A 2 - Seal Assembly (71,4 mm) WRENCH THREAD I I 3 - Cap TYP. FLATS RELIEF 4 4 - Bulb mil A. / \ 5 ,., 5 Compression Screw — —Wa „_ _„ ___Om 6 - Deflector* NPT NPT L 7/16"(11,1 mm) L 1/2"(12,7 mm) NOMINAL MAKE-IN NOMINAL MAKE-IN UPRIGHT UPRIGHT PENDENT CROSS TY5851 TY5151 TY5251 SECTION FIGURE 1 11.2 K-FACTOR SERIES ELO-231B UPRIGHT-3/4"NPT(TY5151), UPRIGHT- 1/2"NPT(TY5851),AND PENDENT-3/4"NPT(TY5251)SPRINKLERS Operation Installation "FITTING SIDE" TOWARDS SPRINKLER The glass bulb contains a fluid that The Series ELO-231B Sprinklers must FITTING expands when exposed to heat.When be installed in accordance with the fol- the rated temperature is reached, the lowing instructions: fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to NOTES activate and water to flow. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of WRENCH liquid from the bulb. With the sprinkler RECESS held horizontally, a small air bubble should be present. The diameter of the (END"A") air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68°C to 3/32 FIGURE 2 inch (2,4 mm) for the 286°F/141°C W-TYPE 3 SPRINKLER temperature ratings. WRENCH A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 installed in the pendent position, and to 20 ft.lbs. (13,4 to 26,8 Nm).A maxi upright sprinklers are to be installed in mum of 30 ft.lbs. (40,7 Nm) of torque the upright position. is to be used to install sprinklers with 3/4 NPT connections. A leak tight 1/2 Step 2. With pipe thread sealant ap- inch NPT sprinkler joint should be ob- plied to the pipe threads, hand tighten tained with a torque of 7 to 14 ft.lbs. the sprinkler into the sprinkler fitting. (9,5 to 19,0 Nm). A maximum of21 ft. Step 3. Tighten the sprinkler into the lbs. (28,5 Nm) of torque may be used sprinkler fitting using only the W-Type to install sprinklers with 1/2 NPT con- 3 Sprinkler Wrench (Ref. Figure 2), nections. Higher levels of torque may except that an 8 or 10 inch adjustable distort the sprinkler inlet and cause Crescent wrench is to be used for wax leakage or impairment of the sprinkler. coated sprinklers. With reference to Do not attempt to make-up for insuffi- Figure 1, the W-Type 3 Sprinkler cient adjustment in the escutcheon Wrench or the adjustable Crescent plate by under- or over-tightening the wrench, as applicable is to be applied sprinkler. Readjust the position of the to the wrench flats. sprinkler fitting to suit. When installing wax coated sprinklers The Series ELO-231B Upright and with the adjustable Crescent wrench, Pendent Sprinklers must be installed additional care needs to be exercised in accordance with the following in- to prevent damage to the wax coating structions. on the sprinkler wrench flats or frame Step 1. Pendent sprinklers are to be arms and, consequently, exposure of Page 4 of 6 TFP342 . bare metal to the corrosive environ- It is recommended that automatic ment. The jaws of the wrench should Care and sprinkler systems be inspected, be opened sufficiently wide to pass �/� tested, and maintained by a qualified over the wrench flats without damag- Maintenance Inspection Service in accordance with . ing the wax coating. Before wrench local requirements and/or national tightening the sprinkler,the jaws of the Series ELO-231B Sprinklers must be code. wrench are to be adjusted to just con- maintained and serviced in accord- tact the sprinkler wrench flats. After ance with the following instructions: Limited wrench tightening the sprinkler,loosen the wrench jaws before removing the NOTES wrench. Before closing a fire protection system Warranty After installation, the sprinkler wrench control valve for maintenance work on flats and frame arms must be in- the fire protection system that it con- Products manufactured by Tyco Fire& trols, permission to shut down the af- Building Products (TFBP) are war- spected and the wax coating re- fected fire protection system must be ranted solely to the original Buyer for touched(repaired)whenever the coat- obtained from the proper authorities ten(10)years against defects in mate- ing has been damaged and bare metal and all personnel who may be affected rial and workmanship when paid for is exposed. The wax coating on the by this action must be notified. and properly installed and maintained wrench flats can be retouched by gen- under normal use and service. This tly applying a heated 1/8 inch diameter Sprinklers that are found to be leaking warranty will expire ten (10) years steel rod to the areas of wax that have or exhibiting visible signs of corrosion from date of shipment by TFBP. No been damaged,to smooth it back over must be replaced. warranty is given for products or com- areas where bare metal is exposed. Automatic sprinklers must never be ponents manufactured by companies NOTES painted, plated, coated or otherwise not affiliated by ownership with TFBP Only of the wax coating ap- altered after leaving the factory. Modi- or for products and components which Only retouchingto the flats and frame fied sprinklers must be replaced. have been subject to misuse,improper armsplied is permitted,hewrench and and frame Sprinklers that have been exposed to installation, corrosion, or which have to is performed only thet the time of corrosive products of combustion, but not been installed, maintained, modi- ishave not operated,should be replaced fied or repaired in accordance with ap- the initial sprinkler installation. if they cannot be completely cleaned plicable Standards of the National Fire The steel rod should be heated only to by wiping the sprinkler with a cloth or Protection Association, and/or the the point at which it can begin to melt by brushing it with a soft bristle brush. standards of any other Authorities the wax, and appropriate precautions Care must be exercised to avoid dam- Having Jurisdiction. Materials found need to be taken, when handling the by TFBP to be defective shall be either age to the sprinklers—before,during, - heated rod, in order to prevent the repaired or replaced, at TFBP's sole and after installation. Sprinklers dam- installer from being burned. option. TFBP neither assumes, nor aged by dropping, striking, wrench authorizes any person to assume for it, If attempts to retouch the wax coating twist/slippage, or the like, must be re- any other obligation in connection with with complete coverage are unsuc- placed.Also,replace any sprinkler that the sale of products or parts of prod- cessful,additional wax can be ordered has a cracked bulb or that has lost ucts.TFBP shall not be responsible for in the form of a wax stick (the end of liquid from its bulb (ref. Installation sprinkler system design errors or inac- which is color coded). Only the correct Section Note). curate or incomplete information sup- color coded wax is to be used, and Frequent visual inspections are rec- plied by Buyer or Buyer's repre- retouching of wrench flats and frame ommended to be initially performed for sentatives. arms is only permitted at the time of corrosion resistant sprinklers,after the In no event shall TFBP be liable, in initial sprinkler installation. With the installation has been completed, to steel rod heated as previously de- contract, tort, strict liability or under scribed, touch the rod to the area re- verify the long term potential integrity any other legal theory, for incidental, of the sprinkler coatings. Thereafter, indirect,special or consequential quiring additional wax with the rod an- p dam- annual inspections per NFPA 25 es,a includingbut not limited to labor gled downward, and then touch the should suffice; however, instead of in- g wax stick to the rod approximately charges, regardless of whether TFBP specting from the floor level,a random one-half inch away from the area re- sampling of close-up visual inspec was informed about the possibility of quiring retouching. The wax will melt such damages, and in no event shall tions should be made, so as to better TFBP's liabilit exceed an amount and run down onto the sprinkler. determine the exact sprinkler condi- y equal to the sales price. tion and the long term integrity of the corrosion resistant coating, as it may The foregoing warranty is made in lieu be affected by the corrosive conditions of any and all other warranties. ex- present. press or implied. including warranties of merchantability and fitness for a par- The owner is responsible for the in- ticular purpose. spection, testing, and maintenance of their fire protection system and de- This limited warranty sets forth the ex- vices in compliance with this docu- clusive remedy for claims based on ment, as well as with the applicable failure of or defect in products, materi- standards of the National Fire Protec- als or components, whether the claim tion Association (e.g., NFPA 25), in is made in contract, tort, strict liability addition to the standards of any other or any other legal theory. authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. TFP342 Page 5 of 6 Ordering P/N 50 - XXX - X - XXX Procedure A Part Number (P/N) is not specified when ordering sprinklers with thread connections per ISO 7/1. Contact your local distributor for avail- SPRINKLER ability. TEMPERATURE TYPE 1 NATURAL BRASS RATING Sprinkler Assemblies with NPT Thread Connection: 510 UPRIGHT 9 CHROME PLATED 155 155°F/68°C Specify: (specify SIN), 11.2 K-factor, 3/4"NPT (specify temperature rating), Series (TY5151) 6 WAX COATED 200 200F/93°C ELO-231 B Standard Response(spec- ify Pendent or Upright) Sprinkler with 512 PENDENT 7 LEAD COATED 286 286°F/141°C (specify finish), P/N (specify from Ta- 3/4"NPT ble B). (TY5251) 8 WAX OVER LEAD Sprinkler Wrench: 501 UPRIGHT Specify: W-Type 3 Sprinkler Wrench, 1/2"NPT P/N 56-895-1-001. (TY5851) Wax Sticks: TABLE B (for retouching wrench damaged PRODUCT SYMBOL NUMBER SELECTION wax coating) 11.2 K-FACTOR SERIES ELO-231B Specify: (Specify color) color coded STANDARD RESPONSE UPRIGHT AND PENDENT SPRINKLERS Wax Stick for retouching (specify tem- perature rating)temperature rated Se- ries ELO-231B Sprinklers, P/N (spec- ify). Red for 155°F P/N 56-065-1-155 Blue for 200°F and 286°F P/N 56-065-1-286 NOTES Each wax stick is suitable for retouch- ing up to twenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200°F sprinklers, and, therefore,the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 150°F). Page 6 of 6 TFP342 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 Eddy Flow The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems systems with a working pressure of 300 psi or less. in commercial and residential construction, Bull Please check with appropriate sources for up-to-date Moose Tube has added Eddy Flow to its listings and approval information. comprehensive line of sprinkler pipe products. As an added benefit, it is more economical to use than Eddy Flow is a specially engineered replacement for schedule 10 due to reduced delivery costs and ease schedule 10, offering better flow characteristics while of handling. Furthermore, Eddy Flow's larger ID providing design flexibility. This product is FM provides an opportunity for downsizing and further approved, as well as UL listed (for U.S. and Canada) cost savings. for roll grooving and welding for use in fire protection COMPARISON 1 1/4 1.660 1.530 1.442 1.380 1.98 1.00 1 1/2 1.900 1.728 1.682 1.610 3.44 1.00 2 2.375 2.203 2.157 2.067 2.78 1.00 2 1/2 2.875 2.705 2.635 2.469 1.66 1.00 3 3.500 3.334 3.260 3.068 1.00 1.00 4 4.500 4.310 4.260 4.026 1.00 1.00 * Corrosion Resistance Ratio BENEFITS • Dual Certified to ASTM A135 and A795. • FM Approved for roll grooved,and welded,and plain-end application in wet systems. • UL Listed(for U.S.and Canada)for joining by welding or by listed rubber gasketed fittings for use in wet,dry, preaction,and deluge type sprinkler systems. • UL Listed(for US and Canada)and FM Approved for use with Victaulic®FIT®Fittings in plain end applications. • Lightweight-saves shipping costs,and offers easier handling, • Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. • Floor stock available in various lengths produced in Casa Grande(AZ),Gerald(MO),and Masury(OH).Also can be ordered in custom lengths.. • Can be used for wet and dry*systems. *Eddy Flow can be hot dipped galvanized to meet FM's requirement for dry systems. PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, C V� us /A 8 Chesterfield,MO 63017 contact your salesperson today at LISTED LOA BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 41> AU A O company e-mail:sales(&,bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 Victaulic® FireLockTM Fittings ✓ctaulic° 10.03 • 1.0 PRODUCT DESCRIPTION Available Sizes • 11/4—8"/DN32— DN200 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic FireLock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS u� DS ® LPCB vds ( E LISTED EN 10311 Regulation(EU) No.305/2011 3.0 SPECIFICATIONS- MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: ❑ Orange enamel. ❑ Red enamel in Europe, Middle East, Africa, and India. ❑ Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION,MAINTENANCE OR SUPPORT. • System No. Location I Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. 1 ✓ctaul.c victaulic.com 4.0 DIMENSIONS I«ctoEl t -1 (7111 ctoE o _6 oe No.001 No.003 No.002 No.006 No.001 i No.003 No.002 No.006 90°Elbow 45°Elbow Straight Tee j Cap ! Actual Approximate Approximate ! i Approximate Approximate Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each 1 inches inches inches lb inches lb inches lb inches lb i DN mm mm kg mm kg mm kg mm kg 1'/4 1.660 - - - - - - 0.82 0.3 DN32 42.4 - - - - - - 21 0.1 1 1 1.900 - - 0.82 0.4 DN40 48.3 - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 �. 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 - 165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - • 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctauhc° victaulic.com • • 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No.002 Actual Elbows Straight Tee Nominal Outside No.001 No.003 Size Diameter 90°Elbow 45°Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1 Ya 1.660 - - _ - DN32 42.4 - - - - 1 1/2 1.900 - DN40 48.3 - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 2 Y2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 -4- 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 _ DN125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 i 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 , 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 219.1 4.0 1.5 10J 4.0 8.515 13.0 - i 33.0 13.0 216.3 4.0 - 1 10.1 4.0 ' The flow data listed is based upon the pressure drop of Schedule 40 pipe. • • 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctauluc' victaulic.com • • 6.0 NOTIFICATIONS General Notes NOTE: When assembling FireLock EZTm couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZTM Style 009N/009H couplings, use FireLockTM No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS VictaulicQ1 F. kor k'RigidCoupling S1_ 005H with Vic-Plus"Gasket System. 29.O1,Victaulic®Terms and Condition_;of i_aie. • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,and the applicable building codes and related Victaulic reserves the right to change product specifications,designs and standard regulations as well as Victaulic performance,maintenance,safety,and warning equipment without notice and without incurring obligations. instructions.Nothing in this or any other document,nor any verbal recommendation, Installation advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale,installation instructions of the product you are installing.Handbooks are included with each shipment guide,or this disclaimer. of Victaulic products,providing complete installation and assembly data,and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product,service,or design is intended,or should be constructed,to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design,or as a recommendation for the use of such Trademarks material,product,service,or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic Company,and/or its affiliated entities,in the U.S.and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. • • 10.03 1539 Rev N Updated 09/2017 ©2017 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic' Victaulic® FirelockTM Rigid Coupling ✓ctaulicl Style 009N 10.64 Patented 1.0 CERTIFICATION/LISTINGS c0us FM LPCB] V`S ushn C104-1a/36 2.0 PRODUCT DESCRIPTION • The FireLock EZTM Style 009N Installation-ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling's unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZTM Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange enamel (North America, Asia Pacific) ❑ Red enamel (Europe) ❑ Hot dipped galvanized Gasket: (specify choice') Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry(oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest •-;,Hection,lade for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. System No. ( . Location I Spec Section Paragraph ti Submitted B I ��y Date Approved Date • • victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. 1 ✓ctaulic' victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 4.0 LISTINGS/APPROVAL 2 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus i FM Vds LPCB j Sch.5 Sch. 10 1 Sch. Sch. Sch. 10 Sch.40 inches 1 psi psi 1 psi psi psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 1 Y4 232 365 1 365 I 175 363 363 i 363 363 32 I 1600 2517 2517 1205 2502 2502 2500 i 2500 1/ I 232 365 365 175 363 363 363 363 40 1 1600 2517_ 2517 1205 2502_ 2502 2500 2500 2 1� 363 365 365 175 363 � 363 363 363 50 1 2502 2517 2517 1205 { 2502 2502 2500 2500 2 Yz I N/A 365 365 175 363 363 363 363 65 2517 2517 1205 2502 2502 2500 2500 3653 3634 363 363 76.1 mm I N/A- 25173 ' N/A N/A 25024 N/A _ 2500 2500 Ii — 1-- .M_ __ 1 3 365 365 175 , 363 363 363 363 80 i N/A 2517 2517 j 1205 2502 2502 2500 2500 4 1365 365 175 363 363 363 363 363 100 2517 2517 1205 2502 2502 2500 2500 708.0mm N/A N/A N/A - 175 363 363 N/A N/A ' 1205 2502 4 2502 5 290 365 363 363 232 125 • N/A ! 2000 2517 N/A 2502 2502 • 1600 N/A a 133.0 mm N/A N/A N/A N/A 2502 4 N/A N/A N/A -I 139.7 mm N/A 290 6 N/A N/A ^�MA 363 4 N/A 232 N/A 6 2000 2502 1600 159.0 mm N/A N/A N/A j N/A 363 4 N/A • N/A N/A 2502 4 165.1 mm N/A 290 6 N/A N/A 363 4 N/A j N/A N/A 1 2000 6 2502 4 6 N/A 290 365 1 N/A 363 363 232 N/A • 150 2000 1 • 2517 2502 2502 1 1600 216.0mm ' N/A N/A N/A F N/A I 250 4 N/A N/A N/A 8 290 365 I 363 363 232 200 N/A ! 2000 2517 � N/A 2502 ' 2502 • 1600 N/A 2 Listed/Approved for wet and dry pipe systems(>—40°F/-40°C)for continuous use in freezing conditions,use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic rs'al!ar;on Manual 000N/009H for details concerning when supplemental lubrication is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 mm pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. • . 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctauI.c® victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 4.1 LISTINGS/APPROVAL Speciality Pipe Pipe Size Pressure Rating Pipe I Size Pressure Rating Pipe I Size Pressure Rating cULus FM cULus FM cULus ? FM inches psi psi inches psi psi inches psi psi kPa kPa kPa kPa kPa kPa 300 365 300 365 t 300 365 j BLT i 11/4-2 EZT 11/4-2 MT , 11/a-2 2068 2517 2068 2517 2068 2517 DF 14-4 300 365 FF I 1 Ya-4 300 365 MLT 1/a—2 N/A 365 2068 2517 2068 2517 2517 r DT 1 Ya—2 2068 2517 FLF 300 365 I I 1 Ya—4 N/A 365 ST 1�/a—2 N/A 365 - — 2517 2517 EF 1 Ya-4 175 175 ' FLT , 1�/a-2 N/A 365 STF 1'/a-4 N/A 365 1206 1206 2517 257 EL I 1 1/a—2 300 365 FLTL 1 Ya—2 N/A `365 TF 2 Ya—4 N/A 365 _ 2068 ; 2517 _ 2517 2517 ET40 7 ya—2 ' 300 I�365 GL /a_2 300 365 �y�LS 1 Ya_2 300 365 2068 2517 2068 2517 f( 2068 2517 EZF 3 4 ' 300 i 365 MF ' 1 Ya-4 300 365365 2068 2517 2068 1 2517 WST 1 1/4-2 N/A 2517 XL 1 Ya—2 300 365 2068 2517 NOTES • BLT=BLT steel pipe manufactured by Allied Tube&Conduit Corp. • DF=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • DT=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • FLF=Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT=Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL=Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL=GL steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ST=STD wall pipe in accordance with ASTM A53. • STF=Steady Flow steel pipe manufactured by AMS Tube Corp. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • WST=WST steel pipe manufactured by Wheatland Tube Company. • XL=XL steel pipe manufactured by Allied Tube&Conduit Corp. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic° victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 5.0 DIMENSIONS Style 009N Y ---, Y Z rTi ���c IIJII tar it Erg '4 III Style 009N Pre-Assembled (Push On Condition) Style 009N Joint Assembled Dimensions Pre-assembled Actual Maximum Maximum Allow. Approx. Nominal Outside Working End Pipe End Bolt/Nut 9 I (Push On Condition) Joint Assembled Weight Size I Diameter Pressure 7 Load 7 Separation8. Size 1 X Y X Y Z Each inches ' inches psi lbs. inches inches 1 inches j inches inches inches inches lbs. mm mm kPa N l mm 'No.l mm mm I mm mm mm mm kg 1• 1/4 1.660 365 j 790 0.10 l 3/8 x 2 I 3.13 I 5.00 2.75 5.00 2.00 1.4 32 42.4 2517 3514 j 2.54 ' 2 M10 x 2 79 127 70 127 51 0.6 1 1/2 I 1.900 365 1035 0 10 12 3/e x 2 3.38 r 5.13 3.00 5.13 2.00 1 1.5 d 40 48.3 2517 4604 2.54 M_10 x 2 86 130 76 130 51 0.7 t.� 2 2.375 '. 365 � -1616 -t 0.12 2 3/e x21h '�4.00 5 63 3.50 1 5.63 2.00 � 1.9 50 60.3 2517 7193 3.05 M 10 x 21h' 102 143 89 143 51 0.9 r_-- T 21/2 2.875 365 2370 0.12 2 3/8 x 2 Yz 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 j 3.05 M 10 x 2 1 114 156 102 156 51 1.0 76.1 mm 3.000 365 2580 0.12 ! 2 3/e x 21/2 4.63 6.00 1 4.13 6.13 2.00 2.1 76.1 2517 11476 3.05 I M 10 x 21 I 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 2 1 Vex 21/2 5.13 6.75 4.63 6.75 2.00 2.3 1 80 88.9 2517 15622 3.05 ! M10 x 21 1 130 171 117 171 51 1.0 _I - 4 I 4.500 365 5805 -1- 0.17 12 l 3/8 x 21/2 1 6.00 - 7.88 5.63 I 7.50 2.13 2.9 ' 100 114.3 2517 25822 4.32 I M10 x 21 ; 152 200 143 191 54 1.3 4.250 365 5175 0.17 ! 3/e x 21/2 1 5.63 7.38 5.38 j 7.38 2.13 3.1 108.0 mm i 108.0 2517 t 2 1 23020 4.32 M10 x 21 i_152 1.87 137 187 54 I 1.4 I - • 5 5.563 365 8870 0.17 j 2 1 x 3 j 7.25 9.25 6.75 9.13 2.25 j 5.0 ; 125 141.3 2000 39456 4.32 i ; M 12 x 3 I 184 235 171 232 57 2.3 j 133.0mm 5.250 365 1 7897 0.17 2 1/2 x 3 6.63 9.00 6.38 9.00 2.25 4.8 I 133.0 2517 _ 1 35106 4.32 M12 x 3 ' 168 229 162 229 57 2.2 j _ 139.7 mm ! 5.500 365 I 8667 0.17 2 1/2 x 3 ( 6.88 9.25 6.75 9.13 2.25 4.9 1 139.7 2517 38529 4.32 a-- M12 x 3 _175 235 171 I4.1' 232 57 2.2 i 159.0 mm 6.250 365 11192 0.17 j 1/2 x 3 Y4 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 12 M12 x 3 1/4' 200 i 254 187 251 I 57 1 2.5 I 165.1 mm 6.500 365 12105 0.17 T 1/2 x 31/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 2517 53813 4.32 ' 2 M 12 x 31/4 203 260 197 ; 257 57 2.7 1 6 6.625 365 12582 0.17 1 Y2 x 31/4 8.38 10.38 W 7.88 10.13 2.25 6.0 1 150 168.3 2000 44469 411 -I .32 12 I M12 x 3 Y4. 213_ 264 200 257 57 2.7 C 8.500 365 ( 20712 0.17 i 5/e x 4 j 10.63 . 13.25 10.25 10.1311'1- 2.63� 11.4 216.0 mm 216.0 1 2517 1._ 55968 I 4.32 2 M 16 x 4 = 270 337 _4_ 260 257 67 5.2 I 8 8.625�' 365v 21326 0.17 5/e x 4 10.88 . 13.38 10.25 �13.13 2.50 11.4 1 200 219.1 1620 94863 4.32 1 M 16 x 4 i 276 340 ! 260 333 64 5.2 2 7 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See the Listings/Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. NOTES • When assembling FireLock EZT"'couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZTM Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZTM couplings are supplied with FireLock EZTA9 Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic Flush-SealTM gaskets are not compatible and cannot be used with the FireLock EZT^'couplings. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • • 6.0 REFERENCE MATERIALS Puc Seal Selection Guide I Ju9N Installation Instructions FireLock EZIO Rigid Coupling • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,as well as Victaulic performance,maintenance, Victaulic reserves the right to change product specifications,designs and standard safety,and.warni ng instructions.Nothing in this or any other document,nor any verbal equipment without notice and without incurring obligations. recommendation,advice,or opinion from any Victaulic employee,shall be deemed to Installation alter,vary,supersede,or waive any provision of Victaulic Company's standard conditions Reference should always be made to the 1.0I 3N i rql i ',k t Z Ri C o ipan; of sale,installation guide,or this disclaimer. Ir s`:a t o: rstruc:hons for the product you are installing.Handbooks are included with Intellectual Property Rights _., � O P Y 6 each shipment of Victaulic products,providing complete installation and assembly data, No statement contained herein concerning a possible or suggested use of any material, and are available in PDF format on our website at www.victaulic.com. product,service,or design is intended,or should be constructed,to grant any license Warranty under any patent or other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design,or as a recommendation for the use of such material,product,service,or design in the infringement of any patent or other intellectual Trademarks property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic,FireLock EZT°,Flush-Sear.,and Installation-Ready'.are trademarks or or patent applications for articles and/or methods of use in the United States and/or other registered trademarks of Victaulic Company,and/or its affiliated entities,in the U.S.and/ countries. or other countries. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic' Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) ®TDLCO Fig. 200E - "Trimline" Adjustable Band Hanger with Felt Lining (B line Fig.B317ONFF) CO OS Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B317ONFC) LlsrE0 Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig.200 - 1/2" (15mm)thru 8" (200mm)pipe Material: Steel, Pre-Galvanized to G90 specifications �I Function: For fire sprinkler and other general piping purposes. Knurled --- V' swivel nut design permits hanger adjustment after installation. � . Features: • (1/2" (15mm)thru 2" (50mm)) Flared edges ease installation for all pipe `"' types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily a B installed around pipe. A For hanger with non-captured nut order Fig. 200S. • (21/2" (65mm)thru 8" (20omm)) Spring tension on nut holds it securely in � _ i' hanger before installation.Adjusting nut is easily removed. (i Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) Fig.200-1/2.200-3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and Factory Mutual Engineering Approved(FM) (3/4" (20mm)thru 8" (200mm)). Fig.2001to200-2 Fig.200-21hto200-8 Conforms to Federal Specifications WW-H-171 E &A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, t,_ Type 10. >; Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts ;' in place of a knurl nut. Order By: Figure number and pipe size , 1 Designed to meet or exceed requirements of FM DS 2-0. . ., , Fig.200 Fig.200C Fig.200E Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. Imm) lbs. (kg) 200-1/2 1/2" (15) 3/8%16 31/8" (79.41 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.41 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 200-21/2 21/2" (65) 3/8"-16 55/8" (142.91 41/8" (104.7) 27 (12.3) 4...,-- 200-3 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (901 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5' 1125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6' (150) 1/2%13 101/8" (257.2) 63/4' (171.4) 73 (33.4) 200-8 8" (200) 1/2%13 131/8" (333.4) 83/4" (222.2) 136 162.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) 63205E - Threaded Rod (right& left hand threads) TL Size Range: 3/8"-16 thru 3"-4 rod specify Length 1�1$ Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. TL 11�1 Rod h with with left and right hand threads-specify Fig. B3205L when ordering.Also �11111 A available Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 83205-3/4 x'L' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) 133205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) B3205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) B3205-11/4 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) 83205-11/2 x'L' 11/2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) B3205-21/2 x'L' 21/2%4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L` 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x'L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR - All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig.100) Fig. 99 - All Threaded Rod Cut To Length ������ �,�,oiv��111�11�111��1 Size Range: 3/8"-16 thru 11/2"-6 rod in 120" (3.05m)lengths or cut to length 1111 Material: Steel N ad Maximum Temperature: 750°F(399°C) c Finish: Plain. Contact B-Line for alternative finishes and materials. L m Order By: Part number, rod diameter and finish �Q Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) ATR 1/4"x 120 99-1/4"i x length 20 240 (1.07) 12 (5.44) AIR 3/8"x 120 99-3/8"`x length 16 730 (3.24) 29 (13.15) AIR 1h"x 120 99-1/2"x length 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 99-5/8"x length 11 2160 (9.60) 89 (40.37) AIR 3/4"X 120 99-3/4"x length 10 3230 (14.37) 123 (55.79) AIR 7/8"x 120 99-7/8"x length 9 4480 (19.93) 170 (77.11) AIR 1"x 120 99-1"x length 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers&Supports 236 Revised4/28/2014 B-Line by E . ®TOLCO. Fig. 4L Longitudinal "In-Line" Sway Brace Attachment c us Size Range — 2"through 8" IPS. LISTED Material — Carbon Steel of APPROVED Function — For bracing pipe against sway and seismic disturbance. ' .,, Approvals — Underwriter's Laboratories Listed in the USA(UL)and Canada(cUL)2"-8". r 10 ; ItfJ Approved by Factory Mutual Engineering(FM), 21/2"-8" pipe. %y --,- Installation Instructions —The Fig.4L is the"braced pipe"attachment component of a longitudinal sway brace assembly. It is intended to be combined with the"bracing pipe"and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. D A To Install — Place the Fig.4L over the pipe to be braced and tighten bolts.Then engage "bracing pipe" into jaw opening and tighten set bolt until hex head snaps off.Jaw attachment can pivot for adjustment to proper brace angle. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. G L Order By — Figure number, pipe size and finish. jl ' '' Y p 4, I• x rot 0 1 II 4-Way Riser Brace r-y (Plan View) i i i I I Dimensions•Weights i i i i Sizes Max.Rec.Load *Max.Rec. Approx. o A C D Bolt Size Lbs.(cULus) Load Lbs.(FM) Wt./100 Longitudinal Brace 2 5% 2 Y16 2'/6 1/2 2015 — 247 2 1/2 6 7/16 2 1/2 2 3/4 V2 2015 3000 253 3 7 2 3/4 3'V16 1/2 2015 1550 268 4 81/2 3 3/s 31116 1/2 2015 1550 348 5 9 3/4 3 7/e 4 3/e 1/2 2015 1450 380 6 111/2 5 51/8 Y 2015 1450 640 8 13 1/4 5% 5% 1/2 2015 1450 728 * Load shown is allowable with brace installed, between 30° -90°. No reduction of load based on brace angle is required. FM approved when used with 1", 11/4",11 "or 2"Sch.40 brace pipe Cooper B-Line, Inc.'s ("Cooper B-Line")seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line,except that,in addition to the other exclusions from Cooper B-Line's warranty,Cooper B-Line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. COOPER B-LINE 1375 Sampson Ave•Corona,CA 92879•800.786.5266• FAX:951.737.0330 www.tolco.com Oil COOPER B-Line FDLCD www.tolco.com NIBCO Revision 5/27/2008 Fig. 1000 - "Fast Clamp" Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Size Range — Pipe size to be braced: 1" thru 6" Schedule 10 thru 40 IPS.* Pipe size used for bracing: 1" and 11/4" Schedule 40 r c L us LISTED IPS. Additionally(UL)approved for use to brace Schedule 7 sprinkler pipe up to 4" (maximum horizontal design load 655 lbs.) Torque requirement 6 — 8 ft. lbs. Material — Carbon Steel Function — For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace sys- tem: Fig. 1000 is used in conjunction with a TOLCO Fig. 900 Series Fitting and joined together with bracing pipe per NFPA 13*or TOLCO OSHPD Approved Seismic Manual, forming a complete sway brace assembly. Features — Field adjustable, making critical pre-engineering of bracing pipe unnecessary. Unique design requires no threading of ;', bracing pipe. Can be used as a component of a 4-way riser brace. II Can be used as longitudinal brace with Fig. 907. Comes assembled and individually packaged with illustrated installation instructions 44 — sizes are clearly marked. Steel leaf spring insert provided to assure installer and inspector necessary minimum torque has been achieved. Installation — The Fig. 1000 is the "braced pipe" attachment component of a lateral sway brace assembly. It is intended to be Maximum Design Load combined with the "bracing pipe" and TOLCO structural attach- 1" thru 4" pipe size — 2015 lbs. ment component, Fig. 980, 910 or 909 to form a complete bracing 6" size — 1265 lbs. assembly. Follow NFPA 13 and/or OSHPD guidelines. To Install — Place the Fig. 1000 over the pipe to be braced, insert bracing pipe through opening leaving a minimum of 1" extension. FM Approved Design Loads* Brace pipe can be installed on top or bottom of pipe to be braced. 1" - 21" - 600 lbs. Tighten hex nuts until leaf spring is flat. It is recommended that the 3" - 4" - 700 lbs. brace angle be adjusted before hex nuts are fully tightened. Approvals — Underwriters Laboratories Listed in the USA(UL) and Canada(cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development .= (OSHPD). For additional load, spacing and placement informa- tion relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Application Note — Position Fast Clamp and tighten two hex nuts until leaf spring flattens. A minimum of 1" pipe extension beyond f the Fig. 1000 is recommended. " -_, Finish — Plain Note — Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By — Order first by pipe size to be braced, followed by pipe size used for bracing,figure number and finish. Lateral Brace • TOLco®brand bracing components are desgined to be compatible ONLY with other TOLCO®brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO®brand bracing components,in the instance that such TOLCO®brand bracing components are used in combination with products,parts or systems which are not manufactured or sold under the TOLCO®brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,where non-TOLCO brand bracing components have been,or are used. OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951 737 5599•FAX 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco.com Schedule 40 Sprinkler Pipe Youngstown Tube manufactures Schedule 40 pipe in sizes 1" thru 2" using only high quality domestic steel. This ensures a uniform superior product for threading, roll grooving, welding or plain end uses. Youngstown Tube's schedule 40 pipe is produced under ASTM A135/A795 Type E, Grade A,NH standards. Every piece is Eddy-Current tested and conforms to internal SPC testing and recording. Youngstown Tube Schedule 40 steel sprinkler pipe is coated with a black enamel coating, continuous color coded red stencil, and stored indoors ready for immediate shipment. Approvals o UL Listed o CUL Listed o FM Approved Youngstown Tube schedule 40 pipe meets the rigorous testing and certification processes of Underwriters Laboratory and Factory Mutual for steel sprinkler pipe with working pressures of 300 psi or less. It also meets the requirements of NFPA 13 and can be used in wet, dry, deluge and preaction systems. Schedule 40 Pieces Feet UL Pipe Pipe Nominal° Weer r Standard ?Weight per Size OD Wall Foot € Length per per Bundle Threaded Bundle Bundle CRR 1 [ 1.315 .133 ' 1.68 21 61 1,281 2,152 1.00 1 '/ 11.660 .140 2.27 r 21 61 -[1,281 1 2,907 1.00 1.900 .145 2.72 [21 44 9 4 I 2,511 1.00 r 2 ! 2.375 .154 r 3.65 21 F37 777 r 2,836 1.00 Youngstown Tube Company 401 Andrews Avenue Youngstown,Ohio 44505 1-866-The-Tube www.youngstowntube.com