Loading...
Report (2) 7a0 FIZZ test' 4T HP Project: -Untitled232 11/12/2019 Prepared By: RECEIVED 4T HP JAN 21 2020 CITY OF TIGARD BUILDING DIVISION Submittal Cover Sheet Unit Report Performance Summary Report Acoustic Summary Certified Drawings Feature Sheet Residential Carrier Products Bldr 1.29k Page 1 of 10 • Unit Report For 4T HP Project: —Untitled232 11/12/2019 Prepared By: 11 1 �r Outdoor Unit Parameters Indoor Coil Parameters Unit Model. 25HCE Unit Model. FB4C Unit Size- 4 Tons (Size 48) Unit Size. 48,000 Btuh (Size 048) Voltage. 208/230-3-60 V-Ph-Hz Cabinet Style. TXV Voltage. 208-1-60 V-Ph-Hz Refrigerant Type. Puron Heating Size No Heat Outdoor Unit Dimensions and Weight Indoor Coil Dimensions and Weight Unit Length• 31.1875 in Unit Length 22.0625 in Unit Width 31.1875 in Unit Width. 21.125 in Unit Height. 28.6875 in Unit Height. 49.625 in Unit Shipping Weight. 232. lb Unit Shipping Weight. 157. lb RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and subsequent owners only to the extent and as stated in the Warranty Conditions and below. The limited warranty period in years,depending on the part and the claimant,is as shown in the table below. Limited Warranty (Years) Item Original Owner _ Subsequent Owner Parts 10* (or 5) 5 Compressor 10* (or 5) 5 *If properly registered within 90 days of original installation,otherwise 5 years(except in California and Quebec and other jurisdictions that prohibit warranty benefits conditioned on registration).See Warranty Conditions below. OTHER APPLICATIONS The warranty period is five(5)years on the compressor,and one(1)year on all other parts. The warranty is the original owner only and is not available for subsequent owners. Ordering Information Part Number Description Quantity Outdoor Unit 25HCE448A005 Comfort Series Heat Pump with Puron 4 Tons Cooling 4 14 SEER @ ARI Conditions Indoor Coil FB4CNP048L00 FB4C Base Series Fan Coil with Puron 48000 BTU Cooling 208/230- 4 1-60 TXV Aluminum Accessories KFAHD0101SLP Gasket Kit for Indoor Unit KFCEH3101 C15 15 kW Electric Heater with Circuit Breaker and Relays for Indoor Unit • The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product Residential Carrier Products Bldr 1.29k Page 2 of 10 Unit Report For 4T HP Project: —Untitled232 11/12/2019 Prepared By: literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29k Page 3 of 10 • Performance Summary For 4T HP Project: -Untitled232 11/12/2019 Prepared By: System Performance System: 25HCE/FB4C Actual Clg Airflow- 1600.0 CFM System Quantity- 4 Standard Clg Airflow 1600.0 CFM Altitude' 0.0 ft Total Net Clg Capacity- 46.77 MBH Linear Pipe Length• 0.0 ft Net Sensible Clg Capacity- 34.62 MBH COP @ 47 F. 3.64 Htg HP Capacity 45.56 MBH COP @ 17 F. 2.56 Htg HP Integrated Capacity 45.56 MBH SEER @ ARI Conditions- 14.0 Heating HP Compressor Power 3.58 kW EER @ ARI Conditions. 11.5 Total System Power 3.99 kW HSPF @ ARI Conditions. 8.2 System Parameters Outdoor Unit Parameters Indoor Coil Parameters Unit Model. 25HCE448A005 Unit Model. FB4CNP048L00 Unit Size(Nominal). 4 Tons(Size 48) Unit Size(Nominal). 48,000 Btuh (Size 048) Voltage- 208/230-3-60 V-Ph-Hz Voltage- 208-1-60 V-Ph-Hz Clg Ent Air DB Ambient 95.0 °F Ent Air DB• 80.00 °F Htg Ent Air DB Ambient 47.0 °F Ent Air WB• 67.00 °F Ent Enthalpy• 31.44 BTU/lb Lvg Air DB• 59.97 °F Lvg Air WB• 57.86 °F Lvg Enthalpy 24.94 BTU/lb Htg Ent Air DB• 70.0 °F Htg Lvg Air DB• 96.4 °F Heating Size(Nominal)• No Heat Total External Static Pressure- 0.50 in wg Electrical Data Outdoor Electrical Data Indoor Electrical Data Unit Voltage. 208/230-3-60 V-Ph-Hz Unit Voltage. 208-1-60 V-Ph-Hz Fan Motor FLA• 1.40 Amps Motor HP• 3/4 HP MCA• 14.5 Amps Motor FLA. 6.0 Amps Max Fuse- 25 Amps Operating Range Min- 187 V Accessory Electric Heater Data Operating Range Max• 253 V EH Part Number KFCEH3101C15 Compressor RLA• 10.4 Amps Electric Heater kW- 15.0 kW Compressor LRA• 123.0 Amps For 4 wire operation (dual circuit): Heater Amps L1/L2- 36.2 Amps Heater+ Motor MCA L1/L2- 53.8 Amps Heater+ Motor MOCP L1/L2- 60 Amps Heater Amps L3/L4- 18.1 Amps Heater+Motor MCA L3/L4• 22.7 Amps Heater+Motor MOCP L3/L4• 25 Amps Accessory Voltage- 208-1-60 V-Ph-Hz The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29k Page 4 of 10 Acoustic Summary For 4T HP Project: —Untitled232 11/12/2019 Prepared By: Outdoor Unit Parameters: Unit Model. 25HCE . Unit Size. 4 Tons (Size 48) Variations. Standard Octave Band Center Frequency, Hz 125 250 500 1k 2k 4k 8k dBA Sound Power,dB 53.0 66.0 69.0 71.0 67.0 64.0 57.0 A-Weighted Sound Power, dBA 79.0 . Indoor Coil Parameters: Unit Model. FB4C Unit Size. 48,000 Btuh (Size 048) Cabinet Style. TXV Octave Band Center Frequency, Hz _ 63 125 250 500 1k 2k 4k Sound Power,dB 69.0 65.0 61.0 58.0 56.0 54.0 50.0 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29k Page 5 of 10 Certified Drawing For 4T HP Project: —Untitled232 11/12/2019 Prepared By: A AIR O13CHARGE l f ! AIR IN ALP ..--F • DISCHARGE .1 i r � 1 t a. kI 1 il• ‘ ''%,,.741F.:,- =NIA, N,..;...,N.s.,..sry, ,..7 , FIELD PO1ER SUPPLY CONN AIR I:—� B Ue;s 22s1lN axoui i ''� �, ryl aEP a rc I I I ill` ` FIELD CONTROL SUPPLY CON.HOLE V "ky... ���Q5T78'IQ122.21 NOLEn0ll6'I¢59.51L[3 li IINE CON.. K 1 4 4 w`1 J alit 19iO1 IPAi9t l 1 d p t l 1 H ,. 0 CVAPOR LINE CONK. + �- �� 1 131k8' `' I16 1I Ii2' NOTES: I 'Y�- II?.TI 6-.. I 3/8'19.5i TIEDONN MOUNTS (2) PLACES • 1.ALLOW 24'(609.6)CLEARANCE TO SERVICE SIDE OF UNIT,49'(1219.2)ABOVE UNIT. z CENTER OF GRAVITY 0. ? 1 I71i' 19 6"{152.41 ON OFE SIDE.12'{304.9)ON REMAINING SIDE.AND 24•{609.6)BETWEEN ill 11 UNITS FOR PROPER AIRFLOW. 3.SERIES DESIGNATION tS THE 131H POSITION OF THE UNIT MODEL NUMBER. Outdoor Model Unit Model. 25HCE Shipping Dimensions and Weights Outdoor Unit Unit Size. 4 Tons (Size 48) Height 33.19 in Voltage. 208/230-3-60 V-Ph-Hz Width 33.31 in SEER 14 Length 33.31 in PartNumber 25HCE448A005 Operating Weight 197. lb Shipping Weight 232. lb Dimensions A B C D E F • G K L M N P 31.19 in 28.69 in 0.88 in 6.56 in 24.69 in 9.13 in 1.13 in 33.25 in -- -- -- -- The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29k Page 6 of 10 Certified Drawing For 4T HP Project: —Untitled232 11/12/2019 Prepared By: UNIT CONNECTION SIZES - NOTE: SUCTION: Ot8 1 024 - S/8' I.O. SWEAT NOTE ALLOW 21' FROM FRONT 030 A 036 - 3/4' 1.D. SWEAT 1. SERIES DESIGNATION IS THE 1ATH POSITION FOR SERVICE 042 THRU 060 - 7/8" I.O. SWEAF OF UNIT PRODUCT NUMBER LIQUID. 3/8' I.D. SWEAT 2. ALL DIMENSIONS ARE IN "INCHES' UNLESS NOTED. CONDENSATE. 3/4' FPT -- -- + 22 1216' 10 3/16" 11' r—7/8' .:'L - " .- I CC ° 7(8', t 3/32' . 2 1/8"- —` t.. OUTLE7 AIR I-3/1" 2' DIA. N 0 'S { 'ISCONNECT OR FOR HIGH VOLTAGE / �` ` POYEA WIRING i CIRCUIT BREAKER N rB"DIA. N.O. ill Ill LOCATION t _ FOR LOW VOLTAGE LTERNATE a CONTROL WIRING T18'.1 WIRING 2'DIA. N.O.'S LOWER, CONTROL, ,�/� FOR NIGH VOLTAGE NOTE MODULAR 1 ELECTRIC HEATER A ALTERNATE' J POWER WIRING IM ITS WILL HAVE ACCESS PANEL T 7r8'DIA H 0. OPPOSITE SIRE CABINET IECE t 15l16' 1' FOR LOW VOLTAGE • 1 318' CONTROL WIRING TOP VIEW r-OPTIONAL FIELD CONVERTED RIGHT SIDE RETURN OPENING INLET 4IR (SLOPE COIL UNITS ONLY) ' OIL ACCESS A' 1 1/2' PANELmi 2 5/8' y� 4 11/16' .1('' (' ITTING �• -LIQUID LINE ' E LIQUID LINE ° 1 1 I ° ' I PANEL IOU ID LINE CONNECTION 3 1216"-ill CONNECTION 4 .44 SUCTION LINE CONNECTION . CONNECTION d I a ��, FOR• jjj jGUCTIoR 14' NODULAR UNITS +�') LINE . I ( tMt`� I9 3/d" CONNECTION __..P, .NO\ (t) 41) MP 6 3/16" i -iits , w_ • . 5' A''-FILTER ACCESS L OPENING PANEL 1 lid" —�1 19 13/16" OPENING ACCESS PANEL CONF LG. FOR d SLOPE COIL DETAILS SLOPE COILS RIGHT SIDE VIEW z CONNECTION LOCATIONS SHOWN FOR OPFLOW OR H DOWNFLOi OR HOWOR I2. RIGHT APPLICATION' AND -"'�� INLET AI� LEFT APPLICATIONS "� INLET AIR FRONT VIEW "A" COILS SHOWN WITH "A' COIL DETAILS CONNECTION OOWNFLOW APPLICATI_:t. LOCATIONS FOR UPFLOW OR HORI2 APPLICATIONS Indoor Coil Unit Model. FB4C Dimensions and Weights Indoor Coil Unit Size- 48,000 Btuh (Size 048) Height 49.63 in Voltage' 208-1-60 V-Ph-Hz Width 21.13 in Cabinet Style. TXV Length 22.06 in PartNumber FB4CNP048L00 Shipping Weight 157. lb Dimensions A B C D E F G H J 49.63 in 21.13 in 19.25 in 19.13 in 15.69 in 23.44 in 23.13 in -- -- The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29k Page 7 of 10 Certified Drawing For 4T HP Project: -Untitled232 11/12/2019 Prepared By: —Ills'TYP. r HORIZONTAL MOOT LOCATIONS- DIMPLES PROVIDED IN TOP PANEL, AIRFLON 44 PLACES) RIRFLO'N AND BACK OF CABINET IN CABINET BOTTOM HOLES PROVIDED t 3/Ib TIP, .136' DIA. HORIZONTAL HANGING HARDNARE TO BE FIELD SUPPLIED. 1-12 PIACESI«Ρ .:tir..1.L1:> 1 [i] TYP, T PLACES) SECONDARY 6RAI F 4 3'4" ..�.. Di PRIMARY DRAT 3 I;I6' SECONDARY DRAIN PRIMARY DRAIN (1 PRIMARY DRAIN 1 13;16" — ICI t illiall -5116' SECONDARY DRAT TYP4 a,� r TYPE]_,- — ECONDARY DRAIN . I PRINARY DNA' Q mot") [I] o_ J o f \ I wm— 14 1:1, D �� 3" 118 �. 2 PLACEDA I, 1♦111,11 i II ` __ v. ' S 71B" I/2" I I/2" 5/16' �1 TYP► 5 TB° TYP► IIId 3�A„ 2 11/16' it PLACES)► t 716' T''N s NO' ' PIP 111 2 3116" 113/16"4- .4— TYP► T 7/8" TYP. DOWN FLOW LOW TYP. 12 PLACES). NOR I Z. RIGHT T.P , HORIZ. LEFT UPFLOW (FIELD CON4'ERTE ) (FIEP CONVERTED) (AS SHIPPED) (AS SHIPPED) LEL Indoor Coil Unit Model. FB4C Unit Size. 48,000 Btuh (Size 048) Voltage. 208-1-60 V-Ph-Hz PartNumber FB4CNP048L00 The Product and Ratings Data in this program is subject to change at any time and without notice. Please refer to the latest product literature and the AHRI directory at www.ahridirectory.org for the most up-to-date information. Residential Carrier Products Bldr 1.29k Page 8 of 10 25HCE4 ComfortTM 14 Heat Pump with Rurons Refrigerant Carrier 1-1/2 to 5 Nominal Tons -�"- turn to the experts Product Data INDUSTRY LEADING FEATURES BENEFflS Efficiency • 14 SEER t`11.0-11.7EER/8.2HSPF • Microtube Technology refrigeration system 1. • Indoor air quality accessories available �ill ��, IC I • Sound level as low as 69 dBA I i ' • Sound levels as low as 68 dBA with accessory sound blanket • Illi Illiill i C i Comfort II!!! • System supports CaR' .Edgee or standard thermostat controls • Reliability I n • Non-ozone depleting Puron€1 refrigerant • Scroll compressor • Internal pressure relief valve J_ t • Internal thermal overload • High pressure switch Comfort ` Loss of charge switch • Filter drier 17ot1_ S E R I � S - Balanced refrigeration system for maximum reliability �i Durability WeatherArmor protection package: Carrier heat primps with Purone refrigerant provide a collection of • Solid.durable sheet metal construction features unmatched by any other family of equipment. The 25HCE4 has been designed utilizing Carrier's non-ozone • Dense wire cod guard depleting Purona refrigerant. • Baked-on powder paint NOTE: Ratings contained in this document are subject to Applications change at any time. Always refer to the AHRI directory g • Long-line-upto 250 feet(76.20 m)total g equivalent length,up twww,ahridirector4,org) for the most up-to-date ratings to•00 feet{60.96 in)condenser above evaporator,or upto 80 ft. information. P (24.38 m)evaporator above condenser(See Longline Guide for more information.) • Low ambient(down to-20'F-28.9°C)with accessory kit Residential Carrier Products Bldr 1.29k Page 9 of 10 FB4C Base Series Fan Coil _ Sizes 018 thru 061 Carrier • tum to the experts Product Data AIR HANDLER TECHNOLOGY AT ITS FINEST The FB4C fan cod has the proven technology of Carrier fan coil units with Puron® refrigerant as well as vertical and horizontal applications.The design features contoured condensate pans with rugged drain connections. ensuring that little water is left in the 41100 pu unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life. features homeowners appreciate. Standard features include grooved tubing and louvered fins.Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners. Units come with solid state fan controls, 1-inch (25mm) thick insulation with R-value of 4.2, multi-speed motors, and fully-wettable coils, Units can accommodate factory- and/or field-installed heaters from 3 to 30 kW The FB4C fan coil design is loaded with popular features.These fan coils utiii7e the latest in electronic commutation motor(ECM) technology through the use of high efficiency. multi-tap ECM motors allowing reliable air delivery with increased static pressure. It comes in a pre-painted(taupe metallic)galvani7Pd steel casing and a factory-supplied power plug for ease of installation. The FB4C unit is shipped with a factory-installed Teflon-ring piston FB4CNF(01S-048) or a Puron refrigerant TXV FB4CNP (018-061). In order to meet the California Title 24 requirement of 1.4% air leakage at 0.5" water, an accessory kit is available. (Refer to Accessories section. Al 0082. Residential Carrier Products Bldr 1.29k Page 10 of 10