Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
F-ie?,52020-0,00 1 /533 61# 56r-e21014' Sr REC;EVLI-P ,,,, ,...44. : .... ., JAN 2 7 2020 CIT Y OF fil(?Aii0 TwyrAT $Lii INC. FIRE PROTECTION, 9095 S.W. Burnham Tigard, OR 97223 COCA COLA CANOPY 15333 SW SEQUOIA PKWY #100 PORTLAND, OR 97224 FIRE PROTECTION EQUIPMENT SUBMITTAL t imicir Worldwide www t co-fire.com Fire Protection Contacts y Products Series TY-FRB, 5.6 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General NOTICE The TYCO Series TY-FRB Sprinklers Description described herein must be installed and .. maintained in compliance with this doc- The TYCO Series TY-FRB,5.6 K-factor, ument, as well as with the applicable :; .` Upright(TY313) and Pendent(TY323) standards of the National Fire Protec- " . ° Sprinklers described in this data sheet tion Association,in addition to the stan- are quick response,standard coverage, dards of any other authorities having decorative 3 mm glass bulb-type spray jurisdiction.Failure to do so may impair sprinklers designed for use in light or the performance of these devices. ordinary hazard,commercial occupan- cies The owner is responsible for maintain- such as banks, hotels,and shop- p �� � ping malls. ing their fire protection system and devices in proper operating condition. The recessed version of the Series TY- The installing contractor or sprinkler FRB Pendent Sprinkler,where applica- manufacturer should be contacted with ble, is intended for use in areas with a any questions. , finished ceiling.This recessed pendent ' sprinkler uses one of the following: Sprinkler • A two-piece Style 15 Recessed p Escutcheon with recessed adjust- Identification ment up to 5/8 inch (15,9 mm) from � the flush pendent position. Number (SIN) • A two-piece Style 20 Recessed Escutcheon with recessed adjust- TY313 Upright 5.6K, 1/2"NPT ment up to 1/2 inch (12,7 mm) from TY323 Pendent 5.6K, 1/2"NPT the flush pendent position. "`- The adjustment provided by the Technical Recessed Escutcheon reduces the Temperature Rating accuracy to which the fixed pipe drops Data 135°F(57°C) to the sprinklers must be cut. 155°F(68°C) Approvals 175°F(79°C) Intermediate level versions of Series200°F(93°C) TY-FRB Sprinklers are described in UL and C-UL Listed 286°F(141°C) Technical Data Sheet TFP357. Sprin- FM, LPCB,and VdS Approved kler guards and shields are described CE Certified Finishes in Technical Data Sheet TFP780. Sprinklers with Polyester Finish are UL Sprinkler: Refer to Table A and C-UL Listed as Corrosion-Resis- Recessed Escutcheon:White Coated, tant Sprinklers. Chrome Plated,or Brass Plated Maximum Working Pressure Physical Characteristics 175 psi(12.1 bar) Frame Bronze 250 psi(17.2 bar)° Button Brass/Copper °The maximum working pressure of 250 psi Sealing Assembly Stainless IMPORTANT (17.2 bar)only applies to the listing by Un- Steel w/TEFLON Always refer to Technical Data derwriters Laboratories,Inc.(UL). Bulb Glass Sheet TFP700 for the "INSTALLER Discharge Coefficient Compression Screw Bronze WARNING"that provides cautions K=5.6 GPM/psi112(80,6 LPM/bar1/2) Deflector Bronze with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FEBRUARY 2014 TFP172 TFP172 Page 2 of 4 Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16"(11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* } I I 5 7/16" (11,1 mm) \ t________. 4 NOMINAL 2'� I-I II 11 MAKE-IN (50,82 m'm) 1 2 2" 1-3/8" 3 (50,8 mm) (34,9 mm) T- --' WRENCH I FLATS 1 r 1/2" NPT** DEFLECTOR* �— 2-7/8" (73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT(TY313)AND PENDENT(TY323)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation Installation The glass bulb contains a fluid which The TYCO Series TY-FRB,5.6 K-factor, WRENCH RECESS expands when exposed to heat.When Upright(TY313) and Pendent(TY323) (USE ONLY the rated temperature is reached, the Sprinklers must be installed in accor- END"A") fluid expands sufficiently to shatter the dance with this section. • glass bulb, allowing the sprinkler to activate and water to flow. General Instructions FIGURE 2 Do not install any bulb-type sprinkler if W-TYPE 6 the bulb is cracked or there is a loss SPRINKLER WRENCH Design of liquid from the bulb.With the sprin- kler held horizontally, a small air bub- Criteria ble should be present. The diameter WRENCH of the air bubble is approximately 1/16 RECESS The TYCO Series TY-FRB,5.6 K-factor, inch (1,6 mm)for the 135°F(57°C) and Upright(TY313) and Pendent(TY323) 3/32 inch(2,4 mm)for the 286°F(141°C) ��- Sprinklers are intended for fire protec- temperature ratings. /i yl tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or should be obtained by applying a min Approval agency(such as, UL Listing imum to maximum torque of 7 to 14 �' is based on the requirements of NFPA ft. lbs. (9,5 to 19,0 Nm). Higher levels err 13, and FM Approval is based on the of torque can distort the sprinkler Inlet requirements of FM's Loss Prevention with consequent leakage or impairment PUSH WRENCH Data Sheets).Only the Style 15 or Style of the sprinkler. IN TO ENSURE 20 Recessed Escutcheon is to be used Do not attempt to compensate for ENGAGEMENT for recessed pendent installations. insufficient adjustment in the Escutch- WITH SPRINKLER WRENCHING AREA eon Plate by under-or over-tightening FIGURE 3 the sprinkler. Re-adjust the position of the sprinkler fitting to suit. W-TYPE 7 RECESSED SPRINKLER WRENCH Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1.Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. TFP172 Page 3 of 4 Step 3. Tighten the sprinkler into the 2-7/8 DIA. sprinkler fitting using only the W-Type (73,0 mm) 6 Sprinkler Wrench(Figure 2).With ref- erence to Figure 1, apply the W-Type 6 2-1/4" DIA. Sprinkler Wrench to the wrench flats. FACE OF r (57,2 mm) Torque sprinklers 7 to 14 ft.-lbs.(9,5 to SPRINKLER 19,0 Nm). FITTING Recessed Pendent Sprinklers I 1 FLUSH The Series TY-FRB Recessed Pendent 3/8±5/16" Sprinklers must be installed in actor- (9,5±7,9 mm) % fl % + I dance with the following instructions. + 1 I Step A.After installing the Style 15 or MOUNTING 1/8 Style 20 Mounting Plate over the sprin- SURFACE (3,2 mm) kler threads, and with pipe-thread sealant applied to the pipe threads, CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) hand-tighten the sprinkler into the TY-FRB PLATE 3/4"(19,1 mm) sprinkler fitting. Step B.Tighten the sprinkler into the FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) sprinkler fitting using only the W-Type WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 7 Recessed Sprinkler Wrench (Figure RECESSED ESCUTCHEON 3).With reference to Figure 1,apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque _ 2-7/8" DIA. sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 (73,0 mm) Nm). FACE OF StepC.After ceilinginstallation and fin- SPRINKLER —2-1/4" DIA. _ ishing,slide on the Style 15 or Style 20 FITTING (57,2 mm) Closure over the Series TY-FRB Sprin- 5/16±1/4" kler and push the Closure over the (7,9±6,4 mm) 1/2"(12,7 mm) Mounting Plate until its flange comes in FLUSH contact with the ceiling. Care and f MOUNTING \ ,7 1/8" ji Maintenance SURFACE (3,2 mm) The TYCO Series TY-FRB,5.6 K-factor, Upright(TY313) and Pendent(TY323) CLOSURE SERIES MOUNTING 1-3/8"(34,9 mm) Sprinklers must be maintained and ser- TY-FRB PLATE 7/8"(22,2 mm) viced in accordance with this section. FIGURE 5 Before closing a fire protection system SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY(TY323) main control valve for maintenance WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 work on the fire protection system RECESSED ESCUTCHEON that it controls, obtain permission to shut down the affected fire protection Modified sprinklers must be replaced. standards of any other authorities hav- systems from the proper authorities Sprinklers that have been exposed to ing jurisdiction. Contact the installing and notify all personnel who may be corrosive products of combustion, but contractor or sprinkler manufacturer affected by this action. have not operated,should be replaced regarding any questions. Absence of the outer piece of an if they cannot be completely cleaned Automatic sprinkler systems are rec- escutcheon, which is used to cover by wiping the sprinkler with a cloth or ommended to be inspected, tested, a clearance hole, can delay sprinkler by brushing it with a soft bristle brush. and maintained by a qualified Inspec- operation in a fire situation. Care must be exercised to avoid dam- tion Service in accordance with local The owner must assure that the sprin- age to the sprinklers before,during,and requirements and/or national codes. fter installation. Sprinklers damaged klers are not used for hanging any a objects and that the sprinklers are only by dropping, striking, wrench twist/ lippage,or the like, must be replaced. cleaned by means of gently dusting s with a feather duster; otherwise, non- Also, replace any sprinkler that has a operation in the event of a fire or inad cracked bulb or that has lost liquid from vertent operation may result. its bulb.(Ref. Installation Section.) Sprinklers which are found to be leak- The owner is responsible for the ing or exhibiting visible signs of corro inspection,testing,and maintenance of sion must be replaced. their fire protection system and devices in compliance with this document, as Automatic sprinklers must never be well as with the applicable standards painted, plated, coated, or other- of the National Fire Protection Associa- wise altered after leaving the factory. tion (e.g., NFPA 25), in addition to the TFP172 Page 4 of 4 P/N* 77 - XXX - X - XXX I � SPRINKLER TEMPERATURE FINISH RATINGS SIN 1 NATURAL BRASS 135 135°F(57°C) 370 5.6K UPRIGHT(1/2-NPT) TY313 g PURE WHITE(RAL9010)'" 155 155°F(68°C) POLYESTER 371 5.6K PENDENT(1/2-NPT) TY323 q SIGNAL WHITE(RAL9003) 175 175°F(79°C) POLYESTER *Use suffix"I"for ISO 7-1 connection; 9 CHROME PLATED 200 200°F(93°C) for example,77-370-4-175-I **Eastern Hemisphere sales only 286 286°F(141°C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for avail- www.tyco-fire.com. ability.When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify:Series TY-FRB Upright or Pen- dent (specify)Sprinkler, SIN (specify), K=5.6, Quick Response, (specify)tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify:Style 15 Recessed Escutcheon with (specify`)finish, P/N (specify`) Specify: Style 20 Recessed Escutch- eon with(specify`)finish, P/N(specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. t co TEFLON is trademark of The DuPont Corporation. Fire Protection Products Eddythread4O A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: • Has a Corrosion Resistance Ratio of 1.0 • Has a Pressure Rating of 300 psi • Is Lighter Weight Than Schedule 40 • Is Approved by Factory Mutual and Listed by Underwriters Laboratories • Is Produced in Accordance to ASTM A-135 and A-795 • Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves • Is Produced From Steel With Excellent Properties of Strength and Threadability • Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* • Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 1 1/4 2.070 1.418 51 1 1/2 2.547 1.654 44 4%4,, 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 1.00 1 1/4 1.00 1.00 1 1/2 1.00 1.00 2 1.00 1.00 *Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems � 1819 Clarkson Road Chesterfield,MO 63017 For additional information, contact your salesperson today at U� DS A � (� 1 I BULL MOOSE TUBE COMPANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED CCC..J77 FAX:(636)5iooset 5 inthe USA, 2 from Canada www.bullmoosetube.com call(800)882-4666 A Le_FAQ)company e-mail:sales@bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 ICI . -- Ductile Iron Fittings- Class 300 UL/FM • c el US APPROVED LISTED A Fig, 35E 3-90°Elbow Size Part Number A Packing Weight -"��y� j in in Inner Master lb _ __4 ... 1:2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 A 1 35E 3010 1.50 40 80 0.5 !RUi I 1-1/4 35E 3012 1.75 t-25 50 0.8 1-1/7 35E 3014 1.94_ 18 36 1.1 2 35E3020 2.25 10 20 1.8 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3- 90°Reducing Elbow B Size A B PackingWeight in Part Number in in Inner Master Ib . 1� ( 3/4 x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 �- 1 x 3/4 35RE3010006 1.38 1.45 50 100 0 4 f i�i A 1-1/4 x 1/2 358E3012004 1.34 1.53 35 70 0.5 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4 x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 351-Th3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 359E3020010 1.73 2.02 16 32 1.2 2 x 1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow Size Part Number A Packing Weight �A in in Inner Master lb �, 1/2 35[ 3004 0.88 150 300 0.2 /t, 4.3/4 35F 3006 0.98 --,80 160 0.3 l 1 35f 3010 1.13 40 80 0.5 I� 1-1/4 35F3012 1.29 25 50 0.7 1-1/2 35F 3014 1.44 20 40 1.0 j�i 2 35F 3020 1.69 10 20 1.6 2-1/2 35F 3024 1.95 i 4 8 2.7 Fig. 35T 3- Tee Size Part Number A Packing Weight - in in Inner Master lb ��iT��I JA 112 351 3004 1.13 80 160 0-3 3/4 351 3006 1.31 30 60 0.5 �1II 35T 3010 t50 25 50 0.7 sa 1-1/4 35T 3012 1.75 ..10 , '.20 1.1 „. ` '' A iE A 1-1/2 35T 3014 1.94 10 20 1.5 - 2 35T 3020 2.25 " k: 6 _ 12 2.4 2-1/2 351 3024 2.70 4 8 4.3 • 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com .-- Ductile Iron Fittings- Class 300 UL/FM t j • c � us 41> APPROVED A Fig. 35CP3 -Straight Coupling with Ribs LesTED • Size Part Number A Packing Weight --_- in in Inner Master_ lb 2 35CP3004 138 200 00 0.1 3/4 35C83006 1.63 100 200 t.'. 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 2; 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 <.: 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Fig. 35RC3 -Hex Reducing Coupling ISize A Packing Weight N; - in Part Numberin Inner Master Ib Ail A 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 ; 1-1/4 x 34 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size A Packing Weight Part Number B in in Inner Master lb ' 1 x 1/2 35HB3010004 1.06 180 360 0.2 ^A 1 x 3/4 35HB3010006 1.06 180 360 0.1 1-1/4 x 1 35HB3012010 1.19 90 180 0.2 1-1/2 x 1 35HB3014010 1:25 75 150 0.4 1-1/2 x 1-1/4 351-)33014012 1.25 75 150 0.3 2 x 1 35HB3020010 1.38 40 80 0.6 2 x 1-1/4 35HB3020012 1.38 40 80 0.6 2 x 1-1/2 I 35HB3020014 1.38 40 1 80 0.6 Fig. 35SP3 -Square Head Plug Size Part Number A Packing Weight in in Inner Master lb 1/2 35SP3004 0.94 600 1200 0.07 A 3/4 35SP3006 1.12 350 700 ,. 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 1r. 1200 t 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 t1 s 90 ' 0.6 Fig. 35U 3- Union with Brass Seat A Size Part Number A Packing Weight ' - iq-- in in Inner Master lb o I 35U 3010 2.19 20 4D 1.0 1.2 ;,�� 1-1/4 35U 3012 2.50 15 30 mI 2 35U 3014 2.62 10 20 1.7 85266r.10_ 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com ES-A-4000E-FP Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Series 4000B-FP Reduced Pressure Zone Assemblies Sizes: 1" - 2° Series 4000B-FP Reduced Pressure Zone Assemblies are x P designed to protect potable water supplies in accordance with national plumbing codes and water authority requirements. This series can be used in a variety of installations, including the prevention of health hazard cross connections in piping systems . or for containment at the service line entrances This series features two in-line, independent check valves, ..` captured springs and replaceable check seats with an inter mediate relief valve. Its compact modular design facilitates easy maintenance and assembly access. 2" 4000BM2-FP-GV Features •Single access cover and modular check construction for ease of maintenance •Top entry — all internals immediately accessible •Captured springs for safe maintenance •Internal relief valve for reduced installation clearances •Replaceable seats for economical repair •Bronze body construction for durability — 1"to 2" •Ball valve test cocks — screwdriver slotted — 1"to 2" •Large body passages provides low pressure drop •Compact, space saving design •No special tools required for servicing •Gear operated, slow close shutoffs •Pre-wired tamper switch(2)per shutoff Specifications A Reduced Pressure Zone Assembly shall be installed at each potential health hazard location to prevent backflow due to back- siphonage and/or backpressure.The assembly shall consist of NOTICE an internal pressure differential relief valve located in a zone The information contained herein is not intended to replace the full between two positive seating check modules with captured product installation and safety information available or the experience springs and silicone seat discs. Seats and seat discs shall be of a trained product installer.You are required to thoroughly read all replaceable in both check modules and the relief valve.There installation instructions and product safety information before begin- shall be no threads or screws in the waterway exposed to line ning the installation of this product. fluids. Service of all internal components shall be through a single access cover secured with stainless steel bolts.The assembly shall also include two gear operated slow close resilient seat- ed isolation valves,four resilient seated test cocks and an air gap drain fitting.The assembly shall meet the requirements of: USC Manual 8th Editiont;ASSE Std. 1013;AWWA Std.C511; CSA B64.4.The assembly shall be an Ames Fire&Waterworks Series 4000B-FP. # Ames Fire&Waterworks product specifications in U.S.customary units and metric are approximate and are provided for reference only.For precise measure- ments,please contact Ames Fire&Waterworks Technical Service.Ames Fire&Waterworks reserves the right to change or modify product design,construction, FIRE' AT E R W Q R KE specifications,or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire&Waterworks products previously or subsequently sold. A WATTS Brand Materials Pressure-Temperature Bronze body construction, silicone rubber disc material in the Suitable for supply pressures up to 175 psi(12.06 bar)and first and second check plus the relief valve. Replaceable poly- water temperature to 180°F(75°C)continuous. mer check seats for first and second checks. Removable relief valve seat,cover bolts. Available Models Standardly furnished with NPT body connections. Series No suffix Female NPT Inlet/Outlet 4000B-FP furnished with gear operated,full port, resilient seat- GV Grooved Inlet/Outlet ed, bronze ball valve shutoffs. Standards AWWA C511-92, IAPMO File No. 1563 Approvals S51F,FO c SP® 0 �L NOTICE p Inquire with governing authorities for local installation requirements us 1013 B64.4 Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Dimensions — Weights E Top View IIEl 11111111 r 'Al- 1 A*0111 , 1 1-11 � (M j + r r _ . - � _ _ F � -�- `II let es, ite no 111 1011111111 11113111111.11111 11111: G Ilnl 1111111��'�11li!I���1 III!IIIII: B l , J A MODEL SIZE DIMENSIONS WEIGHT A B C D E F G H I FNPT GROOVED in. in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs. I kgs. 4000BM2-FP 1 131/4 337 131/4 343 513/6 148 3/ 89 25A6 59 914 235 53/4 146 2% 73 2% 73 15% 397 15.8 7.2 4000BM2-FP 11/4 155/6 397 16 406 61/6 156 33/4 95 2% 60 111/6 283 61/6 154 2% 73 33/s 81 17% 454 19.1 8.7 4000BM2-FP 11 16% 416 161h 419 6% 162 4 102 2% 60 115/16 287 61A 159 2%6 73 3% 86 18% 473 20.8 9.4 4000BM2-FP 2 1916 486 192%6 500 71/4 191 41/4 108 31% 83 13'/6 341 61/4 165 2% 73 3% 92 21% 543 30.4 13.8 Strainer sold separately **Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. 2 Capacity Performance as established by an independent testing laboratory. "Typical maximum system flow rate(7.5 feet/sec., 2.3 meters/sec.) 1 1'h° y kPa psi * kPa psi O 207 30 y 207 30 - 172 25 J 172 25 7 138 20 d 138 20 O 103 15 N 103 15 - d 69 10 i 69 10 34 5 0_ 34 5 0 0 0 0 0 5 10 20 30 40 50 60 70 80 gpm pp 0 10 20 30 40 50 60 70 80 90 100 110 120 gpm AP 0 19 38 76 114 152 190 228 266 304 Ipm 0 38 76 114 152 190 228 266 304 342 380 418 456 Ipm 7.5 15 fps 5 7.5 10 15 fps 2.3 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate kPa psi 1'/4" 2" * kPa psi y 172 25 207 30 —I• 138 20 vi 172 25 ca 103 15 J 138 20 vyi 69 10 ----- d 103 15 H 69 10 • 34 5 i 34 5 0 o a 0 10 20 30 40 50 60 70 80 gpm o pp0 20 40 60 80 100 120 140 160 180 200 gpm AP 0 38 76 114 152 190 228 266 304 Ipm 0 76 152 228 304 380 456 532 608 684 760 Ipm 5 7.5 10 15 fps 5 7.5 10 15 fps 1.5 2.3 3.0 4.6 mps 1.5 2.3 3.0 4.6 mps Flow Rate Flow Rate 3 For additional information, visit our web site at: AmesFireWater.com FIRE&WATERWORKS A WATTS Brand USA:Backflow Tel:(978)689-6066•Fax:(978)975-8350•AmesFireWater.com USA:Control Valves Tel:(713)943-0688•Fax:(713)944-9445•AmesFireWater.com Canada: Tel:(905)332-4090•Fax:(905)332-7068•AmesFireWater.ca Latin America: Tel:(52)55-4122-0138•AmesFireWater.com ES-A-4000B-FP 1935 ©2019 Ames Fire&Waterworks �" re Proteci©n Expans orlid ri gtgs �� AMTROL, 175 PSIG Working Pressure Construction Application Shell ASME Approved Steel • For use in fire protection systems. Diaphragm High-Performance Rubber Compound •Accommodates the expanded volume of system fluids that result from Liner Material Polypropylene temperature changes. System Connection Stainless Steel • Keeps system pressure below the pressure limitations of system components to prevent damage. Finish FPT Red Air Valve Schrader Valve w/EPDM Seats •Can be used with water, glycerin and propolyne glycol systems. Factory Precharge 25 PSIG(1.7 bar) • Designed and constructed per ASME Code Section VIII, Division 1. •Sight glass and seismic restraints available on Models FPT-20VC Performance through FPT-210VC. Min./Max.Operating Temperatures -20°F(-29°C)to 200°F(93°C) Maximum Working Pressure 175 PSIG(12 bar) Warranty 1-Year ASME In-Line Models SYSTEM CONNECTION SYSTEM CONNECTION Model System g CHARGING g Tank A B Shipping VALVE Number Volume Tank Height Tank Diameter . Weight VALVE GING Conn (NPTF) Gal Lit In mm In mm In Lbs Kg MODELS. MODELS FPT-1C 1.5 5.7 8% 222 8% 210 ' 16 7 A FPT-1-C FPT-20V-C FPT-5-C FPT-5C 2.1 8.0 10% 264 10 254 ' 21 10 FPT-12-C FPT-3oV-C A FPT-42v-C FPT-12C 6.4 24.0 15% 397 12 305 % 36 15 FPT-60V-C FPT-70V-C ASME Stand Models Tank A g C System Shipping Model Volume Tank Height Tank Diameter Stand Conn. Weight Number Diameter (NPTF) �-C--• Gal Lit In mm In mm In mm In Lbs Kg B CHARGING FPT-20VC 8.0 30 19% 495 12 305 10% 273 % 52 24 VALVE FPT-30VC 14.0 53 19% 486 16% 419 12' 324 ' 97 44 FPT-42VC 17.5 66 24% 616 16% 419 12% 324 ' 116 53 MODELS FPT-80V-C FPT-60VC 25.0 95 33 838 16% 419 12' 324 ' 154 70 A FPT-120V-C FPT-180V-C FPT-70VC 34.0 129 41% 1054 16% 419 12' 324 ' 197 90 FPT-210V-C FPT-80VC 53.0 200 35% 908 24 610 16 406 1'% 251 114 FPT-120VC 66.0 250 43' 1111 24 610 16 406 1% 281 128 CONEc ION FPT-180VC 77.0 292 48% 1235 24 610 16 406 1% 353 160 FPT-210VC 90.0 341 55% 1410 24 610 16 406 1% 382 173 All dimensions and weights are approximate. Job Name Notes t' Engineer ® UL APPROVED Contractor goot:? P.O.No. •E"Sales Rep. MADE IN USA F" o Model No. MC4400(06/19) Worthington Industries Inc., 1400 Division Road,West Warwick,RI 02893 USA T:401.884.6300 www.amtrol.com 91 Pipe Hangers Fig. 200- "Trimline" Adjustable Band Hanger (B-Line Fig.B317ONF) OTOLCO- Fig. 200F- "Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig.B317ONFF) Fig. 200C- "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig.B317ONFC) LISTED Fig.200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm)thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications ,,� Function: For fire sprinkler and other general piping purposes. Knurled u swivel nut design permits hanger adjustment after installation. �% Features: ®1. • (1/2" (15mm)thru 2" (5omm)) Flared edges ease installation for all pipe `_a types and protect CPVC plastic pipe from abrasion. Captured design w keeps adjusting nut from separating with hanger. Hanger is easily B ,,' / I- ,' nstalled around pipe. A -I For hanger with non-captured nut order Fig. 200S. • (21/2" (65mm)thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm)thru 8" (200mm)) Fig.200-1/z.200-3/4 in the USA(UL)and Canada (cUL)for steel and CPVC plastic pipe and 3 Fig.200-1 to 200-2 Fig.200-21/2 to 200-8 Factory Mutual Engineering Approved(FM) ( /4" (20mm)thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E &A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel y materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. ;* Fig.200 Fig.200C Fig.200E Pipe Size Rod Size A B Approx.Wt./100 Part No. in. (mm) in. (mm) in. (mm) lbs. (kg) 200-1/2 1/2" (151 3/8"-16 31/8" (79.41 25/8" (66.7) 11 (5.0) 'r 200-3/4 3/4' (20) 3/8"-16 31/8" (79.4) 21/2" 163.5) 11 (5.0) } 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.51 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) x 200-11/2 11/2" (40) 3/8"-16 37/" (98.4) 27/8" (73.01 14 16.4) ; 200-2 2" (50) 3/8"-16 41/2" (114.3) 3" 176.3) 15 16.9) j 200-21/2 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.71 27 (12.3) 200-3 3" (75) 3/8"-16 57/8 (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/a"-16 73/s" (187.3) 51/4" (133.31 34 (15.6) 200-4 4'' (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 116.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"-13 101/8" (257.2) 63/4' (171.4) 73 (33.4) 200-8 ' 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B Fire Protection Solutions - ine 21 byEA*Pi Threaded Accessories B32O5 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig.103) B3205L - Threaded Rod (right& left hand threads) TL �l Size Range: 3/8"-16 thru 3"-4 rod Specify Length Material: Steel _ Function: Recommended for use as a hanger support in hanger assemblies. TL 110° Rod is threaded on both ends with right hand threads of the length shown.Also ��11 available with left and right hand threads-specify Fig. B3205L when ordering. %) n Thread Size Maximum Temperature: 750°F(399°C) Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Part number, rod size, length and finish Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2" (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2" (63.5) 1350 (6,00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2" (63.5) 2160 (9.61) 1692 (7.52) 03205-3/4 x11.' 3/4"-10 3" (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2" (88.9) 4480 (19.93) 3508 (15.60) B3205-1 x'L' 1"-8 4" (101.6) 5900 (26.24) 4620 (20.55) 83205-11/8 x'L' 11/8"-7 41/2" (114.3) 7450 (33.14) 5830 (25.93) • B3205-1114 x'L' 11/4"-7 5" (127.0) 9500 (42.25) 7440 (33.09) B3205-11/2 x'L' 1 /2"-6 6" (152.4) 13800 (61.38) 10807 (48.07) B3205-13/4 x'L' 13/4"-5 7" (177.8) 18600 (82.73) 14566 (64.79) B3205-2 x'L' 2"-41/2 8" (203.2) 24600 (109.42) 19625 (87.29) B3205-21/4 x'L' 21/4"-41/2 9" (228.6) 32300 (143.67) 25295 (112.51) 83205-21/2 x'L' 21/2"-4 10" (254.0) 39800 (177.03) 31169 (138.64) B3205-23/4 x'L' 23/4"-4 11" (279.4) 49400 (219.73) 38687 (172.08) B3205-3 x`L' 3"-4 12" (304.8) 60100 (267.32) 47066 (209.35) ATR -All Threaded Rod 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length el 111>1'111 Size Range: 3/8"-16 thru 11/2"-6 rod in 120"(3.05m)lengths or cut to length '�11111 �lll Material: Steel g �� � Maximum Temperature: 750°F(399°C) / 01 i Finish: Plain. Contact B-Line for alternative finishes and materials. m L. at Order By: Part number, rod diameter and finish 4 . Part No.-Size x Length Threads Recommended Load Approx.Wt./100 Ft. ATR Fig.99 Per Inch Lbs. (kN) Lbs. (kg) '2: AIR 4/4"x 1 - . 99_1/4"x length 20 240 (1.07) 12 (5.44) 3/ f'120 - `9-3/8"x length i 16 730 (3.24) 29 (13.15) 'AIR 1/2"tx 120 99...1/2"x length , 13 1350 (6.00) 53 (24.04) ATR 5/8"x 120 : -5/8"x length 11 2160 (9.60) 89 (40.37) 5 AT0 3/4"x 120 5 ' 33/4"x length 10 3230 (14.37) 123 (55.79) ATR if"rX 120 �' -'1"/e x length 9 4480 (19.93) 170 (77.11) ATR1"xlie 1°xlength 8 5900 (26.24) 225 (102.06) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. „ tt Pipe Hangers&Supports 236 Revised 4/28/2014 B EL I e by A.IV i5t=; , VERTICAL MOUNT SAMMYS® ,-,: . ,. SAMMYS® for Steel =` Installs VERTICALLY into the bottom of steel structures easily arid quickly! r . 2 1414U''' 1 —" Product Features £IL r* no 1 ;n t •Made with Teks®self-drilling fasteners- . . n Pre' required 1 no pre-drilling required. a �.: .->. 'kW Install into steel ran a from t . .... 22 9 ti �' gauge-1/2 thicknesses. -�.< -{` g. 1- :z ` i Saves time from traditional methods. i t i Wait V u r I •Reduces installation cost. " 1 •Quick to install using the Sammy Nut . Driver with an 18V cordless drill/driver. '0.,:ilUtt,O, ' =,--4,4---,.........e-Fr--.- ,- -.-- -'.'--:,',...-. :,::-..-,...:-..,,--../..,,,,..Ar 4,-;*.w-144-.4*,.. ',- .1'-,'4;•-•:.,n.'-.-"'" ,L,,.; ' esteig',',.--,',,z--,Fp'Or.,,-,ve--o.v,-:§,:,.--o,,,,; Load 1 Ibs `N `. -=.; 1/4" 8024957 DSTR 100* 1/4-20 x 1"TEKS 3 1510 20 a. r fi ( g ) ,A , . .036"-20 ga 3/16"� 25 125 1/4" 8025957 DST 100 1/4-14 x 1''TEKS 3 446 (20 ga.) 036"-20 ga 3/16" 25 125 ?Y �� � 1/4" 8026957 DST 150 1/4-14 x 1-1/2"TEKS 3 970(16 a. • ���'. .r ;:µsr 9 ):;'*'+; . �'�, .036"-20ga 3/16" 25 125` 1/4" 8027957 DST 200 1/4-14 x 2"TEKS 3 446 (20 ga.) 036"-20 ga 3116" 25 125 �. : 1/4" 8030957 TEK 500 12-24 x 1-1/2"TEKS 5 3125 (3/16")'`€,' ,,,_ r _ , . �� .187°-3/16" 1/2" 25 125 ; fi; > .NQ,0 3/8" 8038957 DSTR 1* 1/4-20 x 1"TEKS 3 1510 (20 ga.) 1500 1475 .036"-20 ga 3/16" 25 125 r Q O 3/8" 8037957 DSTR 1-1/2* 12-24 x 1-1/2"TEKS 5 1510 (3/16") 1500 060"-16 a. 1/2" 25 125 " `� IZ Q„0 3/8" 8039957 DSTR 516* 5/16-18 x 1-1/4"TEKS 3 2200 (20 ga.) 1500 1475 .036"-20 ga 1/8" 25 125 446(20 ga.) / - ;, 3/8" 8040957 DST 10 1/4-14 x 1"TEKS 3 ,, .036%20 ga 3/16" 25 125 #14 Black -`_ 970(16 ga.) ;<�� - ��` - %< Nut Driver � 3/8" 8077925 DST10-SS 1/4-14x1"TEKS3 446 (20ga.) Part#8113910 970 (16 ga.) 036"-20 ga 3/16" 25 125 446 20 a. °""`--'>_',"- ; - ,,-,s 2. 3/8" 8041957 DST15 1/4-14x1-1/2"TEKS3 ( 9 ) ' -x-„-u 970 16 a. 036"'-20 ga 3/16" 25 125 } { 9 ) x' 41, ` > 3/8" 8078925 DST 15-SS 1/4-14 x 1-1/2"TEKS 3 446 (20 ga.) 036"-20 a 3/16" 25 125 �:> 970 (16 ga.) 9 446 20 a. itt - 3/8" 8042957 DST 20 1/4-14 x 2 TEKS"3 ( 9 ) A36"-20 ga 3/16" 25 125 1` x'` 970 16 a. 3/8" 8043957 DST 25 1/4-14 x 2-1/2"TEKS 3 446 (20 ga.) 970 (16 ga.) .036"-20 ga 3/16" 25 125 .� 3/8" 8044957 DST 30 114-14 x 3"TEKS 3 970 16 a :,036"-20 ga 3/16" 25 125 ( 9 ) ' ,x :, ;: ww 0 3/8" 8045957 DST 516 5/16-18 x 1-1/4"TEKS 3 1500 (3/16") 1500 �1475 .125"-1/8" 1/8" 25 125 _- �� sx 3/8" 8046957 TEK 50 12-24 x 1-1/2"TEKS 5 3125(3/16") 1500 1475 :: 1,;.187"-3/16" 1/2" 25 125 .,,„,, 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 446 (20 ga.) _ aT 970 (16 ga.) .188"-3/16" 1/4" 25 125 , _ 1/2" 8033925 DSTR 1.0* 1/4-20 x 1"TEKS 3 1510(20 ga.) T "' t�- - T " �.,.r'. ,a ,-'•436"-20 ga 3/16" 25 125 . .,. 1/2" 8034925 DSTR 5.16* 5/16-18 x 1-1/4"TEKS 3 2220 (20 ga.) .036"-20 ga 1/8" 25 125 - '�-� 112" 8035925 DST 5.16 5116-18 x 1-l/4"TEKS 3 1500(3/16") __ v' ``.925"-118" 118" 25 125 = 1/2" 8036925 TEK 5.0 12-24 x 1-1/2"TEKS 5 3125 3/16" ( ) 187"-3/16" 1/2" 25 125 #14 SW Red n:z_ *Includes retaining nut Nut Driver Part#8114910 .:> .:.,:ffi SAMMY wive ea ° or tee .-:;tails VERTICALLY and 6.ii,velsp to 17' in steel struvtu/e Product Features "_ •Eliminates distortion of threaded rod in •Installs into angled Z-Purlin;Allows sloped roof applications. threaded rod to hangplumb. ,..f ` ": •Accommodates 3-1/2 x 12 pitch. •Allows 17°deflection from vertical. - ` Approvals Rod Part Screw Ultimate t .Test FM Test 1Mo Max Box Case :VDescriptions Pullout(ibs) Load(lits) Load x u _ Size Number DescriptionsThick Thick try _ . . :, 3/8" 8137957 Ski-C1STR 1 1l4 E , - 0 3€f6 035" 3116' 25 125 ' f t. , "Includes retaining nut (Does not comply with ROHS requirements)9 1 #14 Black r"'a'- - Nut Driver . SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 ' <= ' contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 6 0 " ' Its torira 4.::,„,- ' ,, '\/// . : ., VERTICAL MOUNT SAMMYS° = }{0 . SAMMYS® for Wood n #s,1';'S ,, -,, the vi:atot rreee: easily et aTi quief , 0 1: -- Not less than 2"nominal width Wood Flooring Product Features (1-1/2") X �� •No pre-drilling required. ``.:'.tom :. Not less than i 3"nominal •Quick to install using the Sammy Nut Driver with an 18V cordless =;m-- = ' V thickness(2-1/2") .: , (depth or side Wood Joist I drill/driver. ,. .. of vertical member) s lir •Saves time from traditional Double Sheetrock methods. For vertical use- Ceiling $ install in center of lower face •Reduces installation cost. Minimum 2'•embedment into base ` � material for NFPA t3 compliance. Composite I Truss Consult truss manufacturer for 'Made in the U.S.A. -_ ' recommended installation point. F " 'Pre-drilling may be required for GST _ T' M' 25-360.Tool available on page 10. tss .,,„4,41:1111 0 g Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case zS ` Size Number Descriptions Pullout(Ibs) Load(Ibs) Load(Ibs) Qty Qty — kikr.{ ` _'. 210(7/16"OSB) 25 125 ` 1/4" 8002957 GST 100 1/4 x 1" 670(3/4"Ply) - s= 1/4" 8003957 GST 200 1/4 x 2" 1760 (Fir) 25 125 1/4" 8004957 GST300 1/4x3" 2060 (Fir) - t 3/8" 8006957 GST.75 1/4 x 3/4" 564 (3/4"Ply) 25 125 -i ' 210(7/16"OSB) 3/8" 8007957 GST 10 1/4 x 1" 300 25 125 _' 3: 670(3/4"Ply) — cl.•0 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 itte*- 3/8" - 8068925 GST 20-SS 1/4 x 2" 1760(Fir) 850 25 125 3/8" 8009925 GST 25-380 3/8 x 2-1/2" 2113 (Fir) 1500 25 125 3, `i . 3/8 8010957 GST 30 1/4 x 3" 2060 Fir Fy #14 Black (Fir) 1500 4475 25, 125 Nut Driver 3/8" 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#8113910 t '':,, . 3/8" ;#.-8011925 GST 40 1/4 x 4 2180(Fir) s,� 1: ., _ f, 25" . 3/8" 8012925 GST 60 1/4 x 6" 2230(Fir) 25 125 5a ` 1/2" 8013925 GST 2 1/4x2" 1760(Fir) 251 1/2" 8014925 GST 2.5-380 3/802-1/2" 2113 (Fir) 25 125 �� 8015925 GST 3 1/4 x 3" 2275(Fir) 25 1/2 8016925 GST 4 1/4 x 4" 2180 (Fir) 25 125 8017925 GST 6 1/4 x 6" 2230(Fir) ., =1 2 : #14 SW Red Nut Driver Part#8114910 ' K SAMMY Swivel Head for Wood : Product Features ,i •Eliminates distortion of threaded rod, •Saves time from traditional methods. •Accommodates up to 3'/"x 12 pitch roof. •Reduces installation cost. kit'Vik4" '.l;- •Allows 17°deflection from vertical. •Made in the U.S.A. : f Part Screw Ultimate UL Test FM Test :A-> Approvals ,, Case ,- .,'.;.Number Descriptions .Pullout(Ibs) Load(fbs) Load fibs) e - .0.� 3/8" 8139957 SH-GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 125 a•0 3/8" 8141957 SH-GST 30 1/4 x 3" 1720(Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into Part#8113910 - contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.sammysuperscrew.com 41:,:, iumnrs:4 \yr licea RFC4FIVIZIN4 C .. w yA T T INC. 311/171:DjVAPV ''.. N2r174I(V7.? S'-:r°P,N\i E PROTECTION ,. . .., .a . : . • , * FIR - P S.W. Burnham . . .. „..... . , , . 9095 OR 97223 Tigard, . ....,„ , '4..,COCA COLA CANOPY 15333 SW SEQUOIA P1(97224wy #100 R PORTLAND, OR FIRE PROTECTION ONS C HYDRAULIC CALCULATI CALCULATION SUMMARY Project Name:COCA COLA CANOPY Project Location: 15333 SW SEQUOIA PKWY#100 Drawing No.:C20-10 City: PORTLAND, OR 97224 Design Areas Design Area Calc. Mode Occupancy Area of Total Water Pressure @ Min. Min. Min. Calculated Hose Margin To Name (Model) Application Source Density Pressure Flow Heads Streams Source (ft2) (gpm) (psi) (gpm/ft2) (psi) (gpm) # (gpm) (psi) 1 Demand(HW) Light Hazard 230 130.3 Required 0.129 7 14.8 2 100 57.2 42.8 File:C:\JOBS 2020\Coca Cola Canopy\Coca Cola Canopy.dwg Date 1/22/2020 Copyright©2002-2012 Tyco Fire Protection Products Page 1 HYDRAULIC CALCULATIONS for Job Information Project Name:COCA COLA CANOPY Contract No.:C20-10 City: PORTLAND, OR 97224 W Project Location: 15333 SW SEQUOIA PKY#100 Date: 1/17/2020 Contractor Information Name of Contractor: Wyatt Fire Protection Address: 9095 SW Burnham St City: Tigard, OR 97223 Phone Number: 503-684-2928 E-mail:M.COLLEY@WYATTFIRE.COM Name of Designer: M.COLLEY Authority Having Jurisdiction: TIGARD Design Remote Area Name 1 Remote Area Location Canopy Occupancy Classification Light Hazard Density(gpm/ftz) 0.129 Area of Application(ft2) 230 Coverage per Sprinkler(ft2) 115 Number of Calculated Sprinklers 2 In-Rack Demand(gpm) 0 Special Heads Hose Streams(gpm) 100 Total Water Required(incl.Hose Streams)(gpm) 130.3 Required Pressure at Source(psi) 42.8 Type of System Wet Volume-Entire System (gal) 184.1 gal Water Supply Information Date 12/17/2018 Location Home Depot Hydrant Source W1 Notes Glycol System File:C:\JOBS 2020\Coca Cola Canopy\Coca Cola Canopy.dwg Date 1/22/2020 Copyright©2002-2012 Tyco Fire Protection Products Page 2 Job:COCA COLA CANOPY Hydraulic Analysis for : 1 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (Ib/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (Ib.s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters Supply 1 :W1 Flow(gpm) Pressure(psi) 0 100 2224 96 Supply Analysis Residual Available Static Pressure Flow Total Demand Required Pressure Node at Source Pressure Pressure (psi) (psi) (gpm) (psi) (gpm) (psi) W1 100 96 2224 100 130.3 42.8 Hoses Inside Hose Flow/Standpipe Demand(gpm) Outside Hose Flow(gpm) Additional Outside Hose Flow(gpm) Other(custom defined) Hose Flow(gpm) Total Hose Flow(gpm) Sprinklers Ovehead Sprinkler Flow(gpm) 30.3 InRack Sprinkler Flow(gpm) 0 Other(custom defined)Sprinkler Flow(gpm) 0 Total Sprinkler Flow(gpm) 30.3 Other Required Margin of Safety(psi) 0 W1 -Pressure(psi) 42.8 • W1 -Flow(gpm) 30.3 Demand w/o System Pump(s) N/A File:C:\JOBS 2020\Coca Cola Canopy\Coca Cola Canopy.dwg Date 1/22/2020 Copyright©2002-2012 Tyco Fire Protection Products Page 3 . Job:COCA COLA CANOPY Hydraulic Analysis for : 1 q 11 I „, ft� f . , 1 I } 1 di 41 i ii 1 loops s ravel 4 i I I ! .,$ l ! 9 s i1 = ' { .' 1 I. i , ° . , , i 1 . ' -1 i, 1 --i 1-, .�r._.,___. .._ ..__ , t 1 y 1i1 , r Li 1 l , ` I ° i 1. R ! i e 1 I i. r i 4 ; y } ' #.. di-� G i , Yq i __ { 41- - # 1 - 1111 6 ` I 1 y � j 111 i k 1 ! 8 1 I f 9 f i t ; t € I 6 - i i ! Ll 1H71 P [ 11 p 1. i 1 1 1 l 1 p ` w it tr � �_�_� � � �_ ,# �--_} � _t _... �- 111.- r 1 1 i r : i,F q.. I . 1 1 d3 masmsoolCIC0105UM 1302 t400 i:-:.160E 11L22 1.92 1600 2092 2100 T*'" 220 3 . Flom,'gp i '.. File:C:\JOBS 2020\Coca Cola Canopy\Coca Cola Canopy.dwg Date 1/22/2020 Copyright©2002-2012 Tyco Fire Protection Products Page 4 Job:COCA COLA CANOPY Hydraulic Analysis for : 1 Curve Intersections & Safety Margins Intersection Safety Margin Curve Name Pressure (psi) Flow (gpm) Pressure (psi) @ Flow (gpm) Supply 100 50 57.2 130.3 Open Heads Required Calculated • Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) Si Overhead 115 5.6 0.1 11.5 7 0.129 14.8 7 Sprinkler s2 Overhead 115 5.6 0.1 11.5 7 0.135 15.5 7.7 Sprinkler File:C:\JOBS 2020\Coca Cola Canopy\Coca Cola Canopy.dwg Date 1/22/2020 Copyright©2002-2012 Tyco Fire Protection Products Page 5 Job name:COCA COLA CANOPY Sheet number: PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added(q)* Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (ft) (ft) (psi) (psi) (in) sl 9 5.6 14.8 1 10.25 120 7 s2 9 5.6 14.8 1.083 0 0.0637 0 10.25 0.7 s2 9 5.6 15.5 1 lx(coupling)=1.17 14.41 120 7.7 06-0 15 30.3 1.083 3x(us.90)=7.01 8.18 0.2397 -2.6 22.58 5.4 ` 06-0 15 0 1 0.79 0 10.5 Ames4000B 06-I 15 30.3 0 0 13.3164 0 *** 0.79 10.5 06-I 15 0 1 1x(us.90)=2.34 26.68 120 21 10 15 30.3 1.083 2.34 0.2397 0 29.02 7 10 15 0 1.251x(us.Tee-Br)=6.85 11.48 120 28 12 14 30.3 1.4181x(us.90)=3.42 10.27 0.0645 0.4 21.76 1.4 12 14 0 3 2x(us.90)=20.99 175.05 120 29.8 15 14 30.3 3.334 20.99 0.001 0 196.04 0.2 15 14 0 4 1x(coupling)=1.39 7.13 120 30 16-0 6.87 30.3 4.31 1.39 0.0003 3.1 8.52 0 16-0 6.87 0 4 2.78 0 33.1 Wilkins 16-I 4.09 30.3 0 0 1.927 1.2 350ADA G&G 2.78 5.4 *** 16-I 4.09 0 41x(us.90)=13.94 7.09 120 39.7 18 -3 30.3 4.31 13.94 0.0003 3.1 21.03 0 18 -3 0 4 119.99 140 42.7 W1 -3 30.3 4.3 0 0.0002 0 119.99 0.0 * Discharge shown for flowing nodes only ©2006 National Fire Protection Association Page 6 . f. W YAT T �- > FIRE PROTECTION, INC. 9095 S.W. Burnham Tigard,OR 97223 Fire Hydrant Fire Flow • PROJECT Sequoia Pkwy. / Home Depot ADDRESS 14800 SW Sequoia Pkwy. CROSS STREET FLOW HYDRANT NE corner of Home Depot property LOCATION STATIC 100 PITOT RESIDUAL 35 GPM 2224, 4" port hose monster used for flow test GPM AT 20 PSI 11,211 calculated per NFPA 291 DATED 12.17.18 7:35 AM MONITOR HYDRANT West side of Home Depot LOCATION STATIC 100 RESIDUAL 96 DATED , 12.17.18 7:35 AM WITNESS WITNESSED BY TITLE ORGANIZATION City of Tigard Public Works SIGNATURE PERFORMED BY Jack Gardner TFP1680 Page 6 of 6 Limited Ordering Testing Instruments Recommended instruments for testing LFP®Antifreeze for installation or main- Warranty Procedure tenance can be purchased through For warranty terms and conditions,visit Contact your local distributor for avail- FISHER SCIENTIFIC, using the follow- www.tyco-fire.com. ability.When placing an order,indicate ing part numbers: the full product name and Part Number Hydrometer 13202421 (P/N). Graduated Cylinder 115822 Thermometer 13201647 LFP®Antifreeze Refractometer 12561346 Specify: LFP®Antifreeze, (specify net contents), P/N(specify): Pallet of 5 gal(19 L)pails, 36 per pallet 54028 Pallet of 30 gal(114 L)drums, 5 per pallet 54029 Note: Minimum order quantity is 1 pallet of 36 pails or 5 drums. Smaller quantities may be purchased through a Johnson Controls authorized distributor. 1400 Pennbrook Parkway,Lansdale,PA 19446 l Telephone+1-215-362-0700 {ten /' �� I)2019 Johnson Controls.All rights r d.All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson Ison �/ ,I LFP is a registered trademark of Johnson Controls;NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; FLOWGUARD GOLD*,BLAZEMASTER*,CORZAN*,and FRC'.SYSTEM COMPATIBLE PROGRAM is a licensed trademark of The Lubrizol Corporation or its affiliates; Controls FISHER SCIENTIFIC is a trademark of Fisher Scientific of ilk TFP168O Page 5 of 6 Care and 3. Discharge a 1/2 gal (2 L) of fluid 3. Discharge a 1/2 gal (2 L) of fluid from the fluid sampling valve con- from the fluid sampling valve con- nection. Collect and seal the sam- nection. Collect and seal the sam- Maintenance ple in a clean and dry 3/4 gal (3 L) ple in a clean and dry 3/4 gal (3 L) The sprinkler system owner is respon or larger container. Allow the sam- or larger container. _ Bible for the inspection, testing, and ple to warm until it reaches the min 4. To measure the refractive index, maintenance of their fire protection imum temperature in Table C. use a digital refractometer that is system and devices in compliance 4. Once the solution reaches the mini- temperature compensating. Fill the with this document,as well as with the mum temperature, fill the 500 ml well in the refractometer with solu- applicable NFPA standards,in addition calibrated cylinder with the solu- tion and shut the cover. Note the to the standards of any authority having tion and gently insert the hydrom- refractive index as shown on the jurisdiction.Contact the installing con- eter into the cylinder to allow it to refractometer. tractor or product manufacturer with float. Fluid may be added to the 5. Verify the refractive index falls with any questions. cylinder until the hydrometer is in the acceptable range listed in Ta- It is recommended that automatic floating. Note the specific gravity as ble C. If the test results for all the sprinkler antifreeze systems be shown on the hydrometer. Check samples are within the acceptable inspected,tested,and maintained by a the temperature using an appropri ranges,the inspection is complete. qualified inspection,testing,and main- ate thermometer. tenance service. 5. Verify the specific gravity falls with- 6. the test results efrom theany cf the samples in the acceptable range listed in Ta- Fluid fall outside of accept Fluid Test ble C. If the test results for all the able ranges, drain out the system, are within the acceptable and pump in new LFP®Antifreeze. At least once a year, an inspection, samplesp Take samples and test again. If the testing,and maintenance service shall ranges,the inspection is complete. samples continue to fall outside of take a measurement of the specific 6. If the test results from any of the the acceptable specifications, then gravity or refractive index of the fluid in samples fall outside of the accept- the system shall be emptied and the LFP®Antifreeze system. The fluid able ranges, drain out the system, vacuumed clean of any remaining must be replaced if either property and pump in new LFP®Antifreeze. fluid. Recharge the system per the deviates from that originally supplied Take samples and test again. If the Existing System Installation sec- within the allowed tolerance,as speci- samples continue to fall outside of tion. If the samples fall within the fied in Table C. the acceptable specifications, then acceptable range, top off the sys- A detailed description of an appropri- the system shall be emptied and tern to replace the liquid removed ate hydrometer or refractometer can vacuumed clean of any remaining for the samples. be found in the sections titled Using a fluid. Recharge the system per the Hydrometer and Using a Refractometer, Existing System Installation sec- NOTICE respectively.A recommended hydrom- tion. If the samples fall within the Contaminants or other foreign materials eter,refractometer and accessories are acceptable range, top off the sys within a sprinkler system may adversely available for purchase, as listed in the tem to replace the liquid removed impact the properties and performance Ordering Procedure section. for the samples. of LFP®Antifreeze.See the Installation It is required to have test equipment Using a Refractometer section for instructions on flushing and calibrated annually to reduce the risk of 1. Ensure that your refractometer is recharging the system if the solution incorrect test results.Two test methods temperature compensating and falls outside of the acceptable range are acceptable per NFPA 25,and either that it measures refractive index. since the last inspection. may be used to verify that the anti- The range of refractive index mea- freeze is within the specification limits. surements should cover the ac- NOTICE ceptable refractive index range list- Using a Hydrometer ed in Table C and the refractometer Use of LFP®Antifreeze shall be in con- 1. Ensure that your hydrometer mea- should have increments of at most formance with all state and local health sures specific gravity. The range 0.0001. and environmental regulations for the of specific gravity measurements location where it is installed. If a small should cover the acceptable spe- 2. Ensure the main supply valve is amount of antifreeze solution is spilled, cific gravity range listed in Table C closed prior to taking a sample to absorbent towels are recommended to and the hydrometer should have in- test. If the valve is open,supply wa- clean up spill. Towels used to clean up crements of at most 0.002. ter will be pulled into the system spill can be disposed of in the garbage. when the first sample is removed Use caution following a spill as the floor 2. Ensure the main supply valve is from the system. Test separate may remain slippery in the area of the closed prior to taking a sample to samples from the top of each sys- spill. Consult with a local waste water test. If the valve is open,supply wa- tem and at the bottom of each sys- treatment plant or council for informa- ter will be pulled into the system tem,or otherwise required by appli- tion on procedures to follow for the dis- when the first sample is removed cable NFPA standards. If the most posal of large amounts of waste water. from the system. Test separate remote portion of the system or the samples from the top of each sys- interface with the wet pipe system Disposal tem and at the bottom of each sys- is not near the top or the bottom Any disposal of LFP®Antifreeze shall tern,or otherwise required by appli- of the system, additional samples be in conformance with all federal, cable NFPA standards. If the most must be checked. state, and local waste regulations. remote portion of the system or the Refer to the LFP® Antifreeze Safety interface with the wet pipe system Data Sheet for more details. is not near the top or the bottom of the system, additional samples must be checked. A z• TFP168O Page 4 of 6 Installation NOTICE NOTICE Storing or carrying the antifreeze solu- Storing or carrying the antifreeze solu- tion in any container other than the tion in any container other than the NOTICE original may introduce contaminants original may introduce contaminants LFP® Antifreeze is pre-mixed at the and reduce the functional life of the and reduce the functional life of the factory per NFPA 13, 13R, 13D. Do solution. solution. not dilute LFP®Antifreeze with water. 5. Fill the system with LFP®Antifreeze. 5. Fill the system with LFP®Antifreeze. Diluting with water or other constitu- The use of a pump with a backflow For LFP® Antifreeze to work cor- ents in the field can adversely impact preventer and pressure capabili- rectly, purge as much air as pos- the properties and performance of the ties to get the system to the sup sible from the system. Accelerat- solution. The functional life of the solu- ply pressure is recommended. For ed corrosion may occur where air tion may be impacted by the end use LFP® Antifreeze to work correctly, pockets exist in the system. environmental conditions. It is recom purge as much air as possible from mended to only use antifreeze in closed 6. After filling the system with LFP® the system. Accelerated corrosion systems as oxygen can contribute to an may occur where air pockets exist Antifreeze,test the system again to increased rate of corrosion. in the system. verify the solution has not been di- luted with remaining liquids in the New Systems 6. After filling the system with LFP® system. Take samples of the solu- Use the following guidelines when pre- Antifreeze, test the system to veri- tion from a high and low point in the paring a new sprinkler system for LFP® fy the solution has not been diluted. system. The test results from the Antifreeze installation: Take samples of the solution from samples shall be the same before 1. Make certain the system has been a high and low point in the system. and after installation for the instal outfitted with air vent valve(s) and The test results from the samples lation to be successful. fluid sampling valve connections shall be the same before and after System Tag per the plans provided by the sys- installation for the installation to be A system tag must be present on an tern designer. The upper sampling successful. antifreeze system main valve identify valve(s) should be easily accessi- Existing Systems in g the following: ble by contractors.The drain valves Use the following guidelines when pre-should be located and oriented in a •paring an existing sprinkler system for Type and manufacturer of the anti- way that allows a variety of connec- LFP®Antifreeze installation: freeze solution used tions with ease. • Volume of antifreeze used 2. The system should be air tight to 1. Inspect all sprinklers for mechani- prevent leakage. cal damage, corrosion, and evi- • Percent concentration by volume of dence of leakage. If any of these antifreeze used 3. Use water to conduct a complete conditions are present, replace the If using LFP®Antifreeze, the percent flush of branch lines and mains to sprinkler per NFPA 25. concentration by volume would be prevent potential risks of contami- 2. The system should be air-tight to 100% since it is a pre-mixed solu- nants. Perform a pressure test per prevent leakage. Air vents are rec- tion. A tag for inspection, testing, NFPA 13, 13R, 13D, to ensure no ommended to reduce the oxygen in and maintenance can also be hung leakage is present.Loss can be de- the system. at the system riser to record annual termined by drop in gauge pressure testing data.Tag design is available on or visual leakage. The water shall 3. Use water to conduct a complete www.tyco-fire.com. be completely removed from the flush of branch lines and mains to system prior to introducing LFP® prevent potential risks of contami- Storage Antifreeze to the system. nants.The water shall be complete Store the product in original con 4. Prior to system with LFP® ly removed from the system prior to tamer and at a temperature Antifreeze,t fillingu the an appropriate introducing LFP® Antifreeze to the between 40°F (4,4°C) minimum and ntifomz and/or hydrometer re-to system. 90°F (32,2°C) maximum. Do not mix frtest the solution to demonstrate 4. Prior to filling the system with LFP® the product with other liquids.Eye and compliance to property ranges in Antifreeze, use an appropriate re- hand protection are recommended Table C. A detailed description of fractometer and/or hydrometer to when handling the antifreeze solution. an appropriate hydrometer or re- test the LFP®Antifreeze to demon- fractometer can be found in the strate compliance to property rang- sections titled Using a Hydrometer es in Table C.A detailed description and Using a Refractometer,respec- of an appropriate hydrometer or re- tively. If the solution is discolored or fractometer can be found in the the container has dirt present,con- sections titled Using a Hydrometer tact Customer Services. and Using a Refractometer,respec- tively. If the solution is discolored or the container has dirt present, con- tact Customer Services. r TFP168O Page 3 of 6 Design NOTICE Fluid Contraction and Expansion gFluids expand and contract when LFP®Antifreeze is not listed for use in exposed to changes in temperatures, Criteria protecting extra hazard occupancies, resulting in changes in fluid density. flammable liquids, or use with ESFR Thermal expansion shall be taken into LFP® Antifreeze is a solution spe- sprinklers. p cifically tested and listed by UL for account when designing or retrofitting use within the strict parameters and Use of LFP®Antifreeze shall be limited a sprinkler system that will use LFP® requirements in this Technical Data to 40 gal in concealed space and attic Antifreeze by use of an expansion tank. Sheet. occupancies. Table A shows the thermal expansion ofer- All fireprotection systems shall conform Hydraulic Calculations a temperaturesp of the solutionprinklat stem Y ent in sprinkler system to state, local,and NFPA requirements For systems greater than volumes, using the equation for sizing if employing the use of LFP®Antifreeze. 40 gal (151 L), pipe sizing shall be the expansion chamber due to thermal determined using the TYCO Sprink- expansion in NFPA 13. Layout and Design Calc Hydraulic Program and/or the p Flow rates, pipe sizing, sprinkler Darcy-Weisbach and Hazen Williams These values and the NFPA 13, 13R, spacing,hanging methods,and system methods. Because of the density of and 13D Standards for the Installation design must be in accordance with LFP®Antifreeze, the k-factor must be of Sprinkler Systems can be used by NFPA 13, 13R, and 13D. Fire sprin- adjusted and the friction loss must be the installer to determine the proper kler systems utilizing LFP®Antifreeze considered in the system design. The expansion or contraction arrangement shall meet the system size limitations flowing pressures are to be based upon of a sprinkler system containing LFP® as follows: a k-factor calculated using the follow- Antifreeze. NFPA 13D ing equation: Expansion Example No limitations on sprinkler system 1 A sprinkler system containing volume. Antifreeze shall only be used KA=7.94Kw✓yA 50 gal(189 L)of LFP®Antifreeze is sub- in above-ground piping. jected to an environmental temperature KA=sprinkler k-factor discharging the of 0°F(-18°C)in the winter months and NFPA 13R-Occupancies with antifreeze solution an increase of system temperature to • Dwelling Units Only Kw=sprinkler K-factor discharging 100°F(38°C)in the summer months,or No limitations on sprinkler system water a temperature change of 100°F(38°C). volume in buildings only containing 'YA=densityof the antifreeze solution This results in fluid expansion of dwellings.Antifreeze shall only be used at the temperature used for testing in approximately 2 gal(8 L). • in above-ground piping. lb/ft3 NFPA 13R-Mixed Use Occupancies Contraction Example Where buildings contain mixed use Note:See Table E for density in lb/ft3. A sprinkler system containing occupancies that are fed by a single 300 gal (1136 L) of LFP®Antifreeze is cp system,the s size shalle Minimum Design Pressure subjected to an environmental tem- sprinkler toe gal system L). size an The minimum design pressure of the perature of 70°F (21°C) with a later bantifreezeelimitedsor4 sprinkler system feeds re n sprinkler system must be the minimum decrease in°system temperature required pressure for the sprinklers to -10°F (-23 C), or a temperature dwelling units, the system size has no used. limitations. Antifreeze shall only be change of 80°F (27°C). This results in used in above-ground piping. Where Fluid Sampling Valve Connection a fluid contraction of approximately an antifreeze sprinkler system feeds The riser must be installed in an area 9.2 gal(35 L). non-dwelling units,it shall be limited to not subject to freezing with a minimum Expansion Tank 40 gal(151 L).If future building renova- temperature of 40°F(4°C).A fluid sam- Reference NFPA 13 for guidance on the tions result in occupancy classification pling valve connection must be located addition of expansion tanks in new and changes,a fire sprinkler system evalu- at the top of each system riser. The existing systems. Vessel sizing should ation must be performed to determine sampling valves should be located be based on the anticipated operat- if any changes are required for the use for ease of access to the valve by ing conditions the system will experi- of antifreeze. contractors. ence and the corresponding expansion NFPA 13 The sampling connection will facilitate values in Table A. Buildings with occupancy classifi- implementing the service requirements An expansion tank is highly recom- cations of Light Hazard and Ordi- outlined in the Care and Maintenance mended for all systems(including exist- nary Hazard Group 1 and 2 are section. ing).Without an expansion tank there is limited to a sprinkler system volume potential for water to enter the system of 40 gal (151 L). Storage applica- which can alter the performance of tions using non-ESFR sprinklers are LFP®Antifreeze. limited to a sprinkler system volume of 40 gal(151 L). Reference NFPA 13, System Require ments of Antifreeze Systems for alter- nate methods. f. TFP1680 Page 2 of 6 Temperature Change Initial 20°F(-7°C) 40°F(4°C) 60°F(16°C) 80°F(27°C) 100°F(38°C) 120°F(49°C) 140°F(60°C) 160°F(71°C) Fluid Volume • gal(L) Approximate Fluid Expansion/Contraction gal(L) 25(95) 0.2(0,8) 0.4(1,5) 0.6(2,3) 0.8(3,0) 1.0(3,8) 1.2(4,5) 1.4(5,3) 1.6(6,1) 50(189) 0.4(1,5) 0.8(3,0) 1.1 (4,2) 1.5(5,7) 1.9(7,2) 2.3(8,7) 2.8(10,6) 3.2(12,1) 75(284) 0.6(2,3) 1.1 (4,2) 1.7(6,4) 2.3(8,7) 2.9(11,0) 3.5(13,2) 4.1 (15,5) 4.8(18,2) 100(379) 0.8(3,0) 1.5(5,7) 2.3(8,7) 3.1 (11,7) 3.9(14,8) 4.7(17,8) 5.5(20,8) 6.4(24,2) 150(568) 1.1 (4,2) 2.3(8,7) 3.4(12,9) 4.6(17,4) 5.8(22,0) 7.0(26,5) 8.3(31,4) 9.5(36,0) 200(757) 1.5(5,7) 3.0(11,4) 4.6(17,4) 6.2(23,5) 7.8(29,5) 9.4(35,6) 11.0(41,6) 12.7(48,1) 250(946) 1.9(7,2) 3.8(14,4) 5.7(21,6) 7.7(29,1) 9.7(36,7) 11.7(42,3) 13.8(52,2) 15.9(60,2) 300(1136) 2.3(8,7) 4.6(17,4) 6.9(26,1) 9.2(34,8) 11.6(44,0) 14.1 (53,4) 16.6(62,8) 19.1 (72,3) NOTES • Interpolation and extrapolation can be calculated for values outside temperatures and volumes listed in Table A. • For examples on calculating fluid expansion and contraction,see the sections titled Expansion Example and Contraction Example,respectively. TABLE A LFP®ANTIFREEZE EXPANSION Approximate Gallons of Fluid/100 ft Tubing Size Steel Schedule PEX CPVC Copper Pipe 40 Pipe Tube Pipe Type L 1/2 in. 1 1.5 • 3/4 in. 2 3.5 2.5 1 in. 4.5 3 5 4.5 1 1/4 in. 8 4.5 8 6.5 1 1/2 in. 11 6.5 10.5 9.5 2 in. 17.5 11 16.5 16.0 2 1/2 in. 25 24.0 25 3 in. 38.5 35.5 4 in. 66.5 NOTES • Values are approximate. TABLE B LFP®ANTIFREEZE PIPE FILL Concentra- Temperature Viscosity, Density tion Specific Refractive °F(°C) Centipoise Temperature of LFP® Gravity Index at 77°F °F(°C) Antifreeze at 77°F (25°C) 0/010(-23,3) 86.7 lb/gal kg/m3 Ib/ft3' (25°C) 36(2,2) 12.8 -10(-23,3) 9.7 1160.2 72.4 100 1.122-1.129 1.3960-1.3995 70(21,1) 6.0 77(25) 9.4 1129 70.3 TABLE C 120(48,9) 2.6 ACCEPTABLE PROPERTY 150(65) 9.1 1093.1 68.2 RANGES OF 150(65,6) 2.3 NOTES LFP®ANTIFREEZE FOR TABLE D 'This column is used in the k-factor equation MINIMUM USE TEMPERATURE provided in the Hydraulic Calculations section. -10°F(-23,3°C) LFP®ANTIFREEZE VISCOSITY ACROSS TABLE E TEMPERATURE RANGES LFP®ANTIFREEZE DENSITY a Worldwide www.tyco-fire.com ti,co Contacts LFP® Antifreeze Agency Listed Solution for Fire Sprinkler Systems General Typical Description Properties LFP®Antifreeze is a pre-mixed freeze Appearance protection solution designed and Liquid,colorless listed for use in wet sprinkler systems. Freeze Point u, The solution is designed for systems -13°F -25°C �*�:.w=B2e _ subject to freezing temperatures that ) " ^ _ 9 to can cause damageequipment or Note:Freeze point is the temperature at � y impede the proper function of the which crystallization begins. i= t� system. The solution has been devel- Density '� oped to meet the requirements of See Table E UL 2901 for compliance to the 2019 editions of NFPA 13,13R, 13D,and the PH 2017 edition of NFPA 25. 7-8 LFP® Antifreeze remains in a liquid Conductivity state at temperatures as low as 1000-140o NS/cm Compatibility -10°F(-23,3°C). Upon operation of the Refractive Index sprinklers during a fire event,the solu- See Table C The following materials are compatible tion immediately discharges from the with LFP®Antifreeze: sprinklers and is followed by water from Specific Gravity the water supply. Use of the solution in See Table C • Steel piping(not galvanized) sprinkler systems eliminates the deliv- Viscosity • Brass materials ery delay times associated with dry See Table D • Stainless steel piping pipe systems. Pour Point • Black steel Allowable Temperature Range -16.6°F(-27°C) • Copper Minimum use temperature: • Bronze -10°F(-23,3°C) Technical • Cast iron Maximum use temperature: • CPVC 150°F(65°C) Data • PEX Fire Performance Approvals • EPDM LFP® Antifreeze has been tested UL Listed • Natural rubber for exposure to fire and fire fighting UL Certified • Nitrile rubber(BUNA-N) effectiveness. FBCTM System Compatible • Styrene-butadiene rubber(SBR) Safe Handling Procedures Note:FBC°'"System Compatible indicates • Fusion bonded epoxy coated ductile LFP®Antifreeze has been formulated that this product has been tested, and is iron to reduce risks to humans and the envi- monitored on an ongoing basis,to assure ronment.Gloves and eye protection are its ch®mical compatibility with Flow uard Gold®, BlazeMaster®and Corzan®pipe NOTICE recommended when handling LFP® and fittings. FBCT°, FlowGuard Gold®, For use with other materials, contact Antifreeze.For additional product infor- BlazeMaster®and Corzan®are licensed Technical Services. mation and Safety Data Sheet, refer to trademarks of The Lubrizol Corporation or www.tyco-fire.com. its affiliates. When transitioning between dissimi- lar metallic piping materials, the use of dielectric unions should be taken into consideration. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to • regulatory and health information. Page 1 of 6 FEBRUARY 2019 TFP168O