Loading...
Report n' za w -4,c,oJ3 s7344( sit/ ' clee )/ Equipment List HEATCRAFTProject Name: REPLACEMENTS FOR Project Location: US,OR \_Worldwide Refrigeration RUSSELL COND UNIT& Quote Expiration: 10/20/2019 EVAPS Submitted On: 01/15/2020 Quote ID: R736006 Submitted By: Jim Cellini NOTE:THIS EQUIPMENT IS PROHIBITED FROM USE IN CALIFORNIA WITH ANY REFRIGERANTS ON THE"LIST OF PROHIBITED SUBSTANCES"FOR THAT SPECIFIC END-USE,IN ACCORDANCE WITH CALIFORNIA CODE OF REGULATIONS,TITLE 17,SECTION 95374.THIS DISCLOSURE STATEMENT HAS BEEN REVIEWED AND APPROVED BY HEATCRAFT REFRIGERATION PRODUCTS LLC AND HEATCRAFT REFRIGERATION PRODUCTS LLC ATTESTS,UNDER PENALTY OF PERJURY,THAT THESE STATEMENTS ARE TRUE AND ACCURATE. Project Detail Prepared For Project Information THERMAL SUPPLY REPLACEMENTS FOR RUSSELL COND UNIT&EVAPS-PROJECTTYPE PAUL HEKKER US,OR Equipment Detail " Material Description OTV Number 1000 COND UNIT LZT060M6CF CU LK SCRL 6HP 208-230V 3PH 60HZ MED 1 Ambient Temp:95°F Suction Temp:25.0°F Voltage:208-230/3/60 Capacity:52,340 BTU/H Refrigerant Type:R404A FACTORY LIQUID LINE OPTIONS LIQUID STANDARD 1 per unit 2000 EVAPS LCA6110AB UC LK LOP AIR 2 FAN 115V 1 PH 60HZ 4 Evap.Temp:25.0°F Voltage:115/1/60 Room Temp: Capacity:11,000 BTU/H Refrigerant Type:R404A FACTORY VOLTAGE ASSEMBLY SELECTION 115/1/60 PSC 1 per unit 3000 TXV's SBFSEAC3X4ODF30 TXV R-404A/R-507 MEDIUM TEMP 4 4000 SOLENOID VA ME10S240-HP 1/2 SOLENOID VALVE 1 LVE 5000 SOLENOID VL MKC2-120V SOLENOID COIL 1 V COIL 6000 TEMP/DEFROS 20611 KE2 TEMP/DEFROST CONTROL 1 T CTRL Notes i ' ' L Project Name: REPLACEMENTS FOR Project Location: US,OR I RUSSELL COND UNIT& EVAPS Item#: 1000 Quote ID: R736006 Submitted On: 01/15/2020 LARKIN Submitted For: PAUL HEKKER Submitted From: THERMAL SUPPLY Submitted By: Jim Cellini Tag: COND UNIT Identity#: COOLER ❑ For Record 0 For Approval By: Date: General Product Information Product Family: LZT Compressor Brand: Copeland Application: Outdoor Compressor Type: Scroll Temperature Range: Medium Temp Compressor Hp: 6 Voltage:(Volts/Ph/Hz) 208-230/3/60 Compressor Model: ZS45K4E-TF5 Refrigerant Type: R404A Number of Compressor(s): 1 - Piping: Standard Coil Type: Microchannel NOTE:THIS EQUIPMENT IS PROHIBITED FROM USE IN CALIFORNIA WITH ANY REFRIGERANTS ON THE"LIST OF PROHIBITED SUBSTANCES"FOR THAT SPECIFIC END-USE,IN ACCORDANCE WITH CALIFORNIA CODE OF REGULATIONS,TITLE 17,SECTION 95374.THIS DISCLOSURE STATEMENT HAS BEEN REVIEWED AND APPROVED BY HEATCRAFT REFRIGERATION PRODUCTS LLC AND HEATCRAFT REFRIGERATION PRODUCTS LLC ATTESTS,UNDER PENALTY OF PERJURY,THAT THESE STATEMENTS ARE TRUE AND ACCURATE. Technical Information Performance Data Ambient Saturated Suction Capacity Altitude AWEF Value Temperature(°F) Temperature(°F) (BTU/H) (ft) 95 25.0 52,340 0 8.35 Compressor(s) Fan Motor(s) y v, yr RLA LRA Quantity Hp FLA Defrost High or Number of MCA MOPD Evap.Fan Defrost Type Low Amps? Contactors Amps Heater Amps 21.5 156 1 1/3 3.5 AIR DEFROST NA 30 50 Unit Specifications _r an Blade(s) :rdx.Net Sound Data ,9 meter (dB) Weight Liquid Line Suction Standard Over Sized ''<,n (lbs) 1/2 1-1/8 20.0 F! 22 r 76 317 Dimensional Drawings) , :a.....-. "..,x. .. ,.. AGENCY LISTINGS 30 1/2 --____......--j C CL us - — -— 4 7/16 AIR FLOW-0. LIQUID 29 5/8 —. --- — - _ - - 31/16 SUCTION - -'"" - — - 3 1/4 �,v ----. 313n6 i =, a.tirkr c7 2 9/16 I• ` ! F 23 1/8 CL— i' IF. 42 7/8 CL I I 4 7!8 1 15l16 t 43 7/8 43/8 --+- —211/16 4 7/16 UOM:Inches Project Name: REPLACEMENTS FOR Project Location: US,OR RUSSELL COND UNIT& EVAPS Item#: 1000 Quote ID: R736006 Submitted On: 01/15/2020 I 1 L1.I 1 I Submitted For: PAUL HEKKER Submitted From: THERMAL SUPPLY Submitted By: Jim Cellini Tag: COND UNIT Identity#: COOLER Standard Features QUALITY SERVICEABILITY • ALL UNITS ARE COMPLETELY LEAK TESTED IN A HELIUM ENVIRONMENT,BUMP • LARGE ELECTRICAL PANEL FOR EASE OF ACCESS TESTED AND ALLOWED TO CYCLE OFF ON THE HIGH AND LOW PRESSURE • PREFABRICATED WIRING HARNESSES FOR TIGHT CRIMP CONNECTIONS AND CONTROL. CONSISTENT LABELING • EACH UNIT HAS A COPY OF THE RUN DATA SHIPPED INSIDE THE ELECTRICAL • RECEIVER WITH FUSIBLE PLUG,LIQUID SHUTOFF VALVE AND CHARGING PORT IS PANEL STANDARD • ELECTRICAL CIRCUITS ARE COMPLETELY CHECKED FOR CONTINUITY • SIGHT GLASS IS EASILY VIEWABLE • ENCAPSULATED,AUTO-RESET,HIGH AND LOW PRESSURE CONTROLS TO • UNIT STAYS ON IF THE HOOD IS REMOVED FOR SERVICING ELIMINATE LEAKS(STANDARD ON ALL HIGH AND MEDIUM TEMPERATURE MODELS, ADJUSTABLE LOW PRESSURE CONTROL STANDARD ON LOW TEMPERATURE MODELS) • PIPING IS LAID OUT TO MINIMIZE STRESS AND VIBRATION AND IS PRE-BENT TO ELIMINATE LEAKS COMPONENT CABINET AND CONSTRUCTION • COMPRESSOR: 1/2 TO 1 HP COMPRESSORS ARE RIGID MOUNTED AND HAVE A • HEAVY DUTY STEEL RAISED BASE WITH 1-1/2'LEGS DISCHARGE LOOP • PAINTED STEEL CABINETS FOR SUPERIOR STRENGTH AND CORROSION • COMPRESSOR: DISCHARGE SERVICE VALVES COME STANDARD ON ALL UNITS PROTECTION • FAN: SPECIFICALLY MATCHED WITH MOTOR AND COIL TO ATTAIN MAXIMUM AIR MOVEMENT AND COOLING Options Mounted Options • DEFROST TYPE-AIR DEFROST • DEFROST TIMER OPTIONS-NO TIMER • BRAND LABEL OPTION-LARKIN • CRANKCASE HEATER OPTIONS-CRANKCASE HEATER • DISCHARGE LINE OPTIONS-HEAD PRESSURE VALVE • SUCTION LINE OPTIONS-SUCTION TUBE ONLY • CABINET OPTIONS-PAINTED-OUTDOOR • COIL SELECTION-ALUMINUM FIN COIL • LIQUID LINE OPTIONS-LIQUID STANDARD Minimum Unit Clearances Walls or Obstructions for Multiple Units with Horizontal Air Flow Horizontal Air Flow AIR FLOW AIR FLOW AIR W* � *W = MIN. FLOW -" MIN• • //• unit width W* MIN. W*iTMIN. wC,."..'`^�j'^"--- A •, ^- r�: -- ``.\e\1`\\ \\\'&�t\N \\\tip\�\`��\�\1�1�\�\\\�� _. Project Name: REPLACEMENTS FOR Project Location: US,OR RUSSELL COND UNIT& EVAPS Item#: 2000 Quote ID: R736006Submitted On: 01/15/2020 1:1‘.1"P:rtiHI Submitted For. PAUL HEKKER Submitted From: THERMAL SUPPLY Submitted By: Jim Cellini Tag: EVAPS Identity#: COOLER ❑ For Record ❑ For Approval By: Date: General Product Information Product Family: LCA6 Motor type PSC Defrost Type: Air Number of Fans: 2 Voltage:(Volts/Ph/Hz) 115/1/60 Fan HorsePower 1/15 Refrigerant Type: R404A Fins per Inch 6 Technical Information Capacity Air Flow Altitude TD SST Capacity CFM Fan Diameter Air Throw(ft) (ft) AWEF Value (°F) (°F) (BTU/H) (ft) Standard w/Collar ..:, 10 25.0 11,000 1,300 12 0 N/A Electrical Data 'an toibr s ,.. Defrost' oafer(s) 111' Dra Pan Heater(s) Watts Amps Watts Amps Watts Amps 164 2 Connections(in) Approx.Net Weight Coil Inlet Suction External Equalizer Drain Side Port Hot Gas Drain Pan 1/2 7/8 1/4 3/4 51 Dimensional Drawing(s) AGENCY LISTINGS 7/8"Electrical y..,,r, Kno 2i/8 © CO F us NS 1 3/4 I 1/2 f 2 1/4—i aw 1 I---4 3/16 • w A j Refrigerant frigerant Electrical 13 !!4 Connection End f Connection End V �r w 6 1/8 4 ,5 li4- -.a_6 1/8 143/4 I 1 J AIR FLOW f 12[/8 �' ll 16 3/4"MPT(14 t , 12 uoM�inches - 45 5(16 Drain Connection 14 13/16 Project Name: REPLACEMENTS FOR Project Location: US,OR L RUSSELL COND UNIT& EVAPS Item#: 2000 Quote ID: R736006 Submitted On: 01/15/2020 LARKIN Submitted For: PAUL HEKKER Submitted From: THERMAL SUPPLY Submitted By: Jim Cellini Tag: EVAPS Identity#: COOLER Standard Features EASE OF INSTALLATION&SERVICE PERFORMANCE • ALL ELECTRICAL COMPONENTS FACTORY WIRED TO TERMINAL BOARD AND • INTERNAL PANELS ARE ISOLATED FOR QUIET OPERATION IDENTIFIED,MAKING IT EASY TO FIELD WIRE THE UNIT • INTERNALLY ENHANCED TUBING AND FIN DESIGN FOR HIGHER EFFICIENCY • CABINET DESIGN FEATURES FRONT ACCESS PANELS ON EACH SIDE FOR EASY ACCESS TO ELECTRICAL AND REFRIGERATION COMPONENTS • LIQUID LINE SOLENOID WIRE HARNESS IS FACTORY-INSTALLED FOR QUICK INSTALLATION • MOTORS PLUG INTO WIRING HARNESS FOR EASIER SERVICING • ON 4-6 FAN MODELS,DRAIN PAN HAS A LANYARD FOR EASY AND SAFE ACCESS • PRE-DRILLED HOLES ON THE BACK OF THE UNIT FOR ROOM THERMOSTAT RELIABLE&DURABLE VERSATILE • ATTRACTIVE WHITE CABINET • LARGE DIAMETER DRAIN HOLE(3/4"ID)IS LOCATED ON THE BACK OF THE UNIT • MOLDED FAN GUARD DESIGN MADE OF STRONG PLASTIC MATERIAL • MINIMAL HEIGHT OF THE LOW PROFILE SERIES MAKES IT IDEAL FOR LOW CEILING • SWEAT CONNECTIONS TO REDUCE POTENTIAL FOR LEAKS COOLERS Options 'caret#Optr"ons • COIL SELECTION-ALUM W/SHRADER • COIL COATING-ALUMINUM • COIL MECHANICAL OPTION-NONE • CONTROLS-NONE • VOLTAGE ASSEMBLY SELECTION-115/1/60 PSC • FAN BLADE SELECTION-STANDARD FAN BLADE • CARTON OPTIONS-STANDARD CARTON - FAN GUARD SELECTION-LARKIN PLASTIC GUARD • NOZZLE SELECTIONS-R22 NOZZLE KIT • NOZZLE SELECTIONS-R404A NOZZLE KIT • Variant condition-null Minimum Unit Clearances .402021205160, 11/2 y H PLAN VIEW 11/2 H 11+2 H tsi x101 PLAN VIEW AIR FLOW}}t i NOTE: -> 11/2 H �-- 3H -► 11/2 H 4-- 3 H=Total Height evaporator coil surface. 0111 .//r�,,/:I +yy,/E,pAlrrigli �r,�1• 4 Two Evaporators One Evaporator