Plans /MJS72020-000 51
//200 A/ 83*1 4"
OVERVIEW OF THE SNAPNRACK ULTRA RAIL SNAPNRACK,ADJUSTABLE END CLAMP. BIN: REVISION:
SYSTEM INSTALLED ON A TYPICAL ROOF SELECT TO MATCH MODULE HEIGHT ife'MODULE SPACING ALL 1 5/7/3014 NEW DETAIL M]A
REFER TO SPECIFIC"ATTACHMENT DETAIL" SNAPNRACK,MID CLAMP. —
FOR DETAILS ON ATTACHING AND SELECT TO MATCH _
WATERPROOFING THE VARIOUS FIN MODULE HEIGHT PV MODULE,TYP. —
SNAPNRACK ROOF ATTACHMENT PRODUCTS ,11
REFER TO SPECIFIC"COMPONENT DETAIL" ��_ PV MODULE,TYP. SNAPNRACK,ULTRA RAIL PV MODULE FRAME,TYP.
!.
FOR DETAILS ON VARIOUS SNAPNRACK ��� `\,,,
SNAPNRACK UNIVERSAL END CLAMP.
• ACCESSARY AND COMPONENT PRODUCTS t ' ' ` MODULE HEIGHT AGNOSTIC AND
►' SNAPNRACK,ULTRA RAIL
BOTH THE SNAPNRACK UNIVERSAL END �� / Y � HIDDEN BENEATH MODULES
CLAMP AND SNAPNRACK,ADJUSTABLE END DETAIL A: ��'� DETAIL B: ���'� DETAIL C: SNAPNRACK,ULTRA RAIL
CLAMP CAN BE USED ON END MODULES SNAPNRACK,ADJUSTABLE END CLAMP SNAPNRACK, MID CLAMP SNAPNRACK, UNIVERSAL END CLAMP
MODULES MAY BE CLAMPED ON SHORT OR / C PV MODULE,TYP.
LONG SIDE PER MODULE MANUFACTURER j ��� I I ..
REQUIREMENTS :,�` c
s I
RAILS MAY BE MOUNTED UP/DOWN OR
ACROSS THE SLOPE OF THE ROOF
k\.--
SNAPNRACK,ULTRA RAIL
REFER TO SNAPNRACK INSTALLATION "RAIL END OVERHANG" "RAIL SPAN"DISTANCE BETWEEN
MANUAL FOR Xe"0 HARDWARE TORQUE DISTANCE FROM RAIL END CENTERS OF TWO ROOF ATTACHMENTS SNAPNRACK ROOF ATTACHMENT,
SPECIFICATIONS TO OUTER ROOF ATTACHMENT CENTER. VARIES WITH ROOF TYPE
NOT TO EXCEED 34%OF ALLOWABLE SPAN
STRUCTURAL MEMBER
SNAPNRACK,ADJUSTABLE SNAPNRACK,MID CLAMP.
END CLAMP.SELECT TO SELECT TO MATCH MODULE HEIGHT
MATCH MODULE HEIGHT / SNAPNRACK ULTRA RAIL "MODULE OVERHANG"
/ DISTANCE FROM RAIL SIDE TO MODULE EDGE.
PV MODULE,TYP. NOT TO EXCEED 25%OF MODULE LENGTH OR
/ AllirP. '
MODULE MANUFACTURER RECOMMENDATIONS
�� �� '��� SNAPNRACK ULTRA RAIL
"-- = T40v- plIPIP Air' CAP,OPTIONAL
1�/i" PPP' /
ROOFING MATERIAL, 110
/} COMP SHINGLE SHOWN,TYP.
-I- ROOF SHEATHING AND
2i 4. UNDERLAYMENT MATERIAL,TYP.
15,4"
STRUCTURAL MEMBER SNAPNRACK ROOF ATTACHMENT,VAIRES WITH
WOODEN RAFTER SHOWN,TIP. ROOF TYPE.REFER TO SPECIFIC"ATTACHMENT DETAIL"
UR-40 RAIL( UR 60 RAIL FOR ATTACHMENT&WATERPROOFING DETAILS
FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
nn �� "xR s S mnrun South"LLCC DESIGNER: M.AFFENTRANGER SCALE: DNS
DRAWING NUMBER: DESCRIPTION: REV
u u�� �� "'m° " "" DRAFTER: M.AFFENTRANGER DAB 5n/2019 SNR-DC-00329 ULTRA RAIL,SYSTEM OVERVIEW,TYPICAL 1
F'i„ s'7 xiwooucraxsracox ui,oa �m ® inie
wxmE" ,", oxaw,x«�. APPROVED BY: B.PETERSON
SNAPNRACK FLASHED L FOOT FOR COMPOSTION ROOF *THE FLASHED L FOOT BASE IS COMPATIBLE WITH BIN: REVISION:
MOUNTING THE FOLLOWING SNAPNRACK L FOOT ASSEMBLIES:
*3, *5 1 5/7/2019 NEW DETAIL MJA
REFER TO SNAPNRACK ENGINEERING CHARTS FOR �s"0 S.S.SERRATED —_
APPLICABLE RAIL SPANS."BIN"NUMBER ON CHART \,.....1, FLANGE NUTSHOULD MATCH"BIN"NUMBER ON THIS DRAWING '0 i �-� I��i *j
546"0 S.S.LAG SCREW MUST EMBED A MIN.OF 24" SNAPNRACK ULTRA
INTO STRUCTURAL MEMBER 90, 92° RAIL 92°L FOOT SHOWN. SNAPNRACK COMP FLASHING
COMPATIBLE WITH ULTRA FOR L FOOT BASE
REFER TO SNAPNRACK INSTALLATION MANUAL FOR RAIL ALL PURPOSE 90°L FOOT
5116"0 HARDWARE TORQUE SPECIFICATIONS
ULTRA RAIL ALL ULTRA RAIL 92° L FOOT: SNAPNRACK COMP
RAIL CAN BE MOUNTED ON EITHER SIDE OF THE PURPOSE 90° L FOOT: BIN 3 L FOOT BASE
L-FOOT
BIN 5
FOR LEVELING DETAILS,REFER TO SNAPNRACK
DETAIL DRAWING"SNR-DC-00332 ULTRA RAIL
COMPONENT DETAIL,LEVELING EXTENSION KIT'
AND/OR"SNR-DC-00333 ULTRA RAIL,COMPONENT
DETAIL LEVELING SPACER ON FLASHED L FOOT' IMPORTANT:APPLY SEALANT AROUND LAG
SNAPNRACK ULTRA HOLE,BETWEEN THE BASE AND SHINGLE,AND
RAIL 92°L FOOT SHOWN. ON THE LAG SCREW BEFORE MOUNTING TO ROOF
COMPATIBLE WITH ULTRA EXPLODED
RAIL ALL PURPOSE 90°L FOOT
MODULE HEIGHT OFF ROOF,RANGE: L-FOOT TO BASE ATTACHMENT SNAPNRACK COMP FLASHING 10° .
UR-40:334"-4 " DOWNSLOPE FROM MUST SLIP UNDER THE UPSLOPE
ROOF PENETRATION SHINGLE COURSE
UR-60:44"-S*'\#
1 FLASHING SHIELDS ENTIRE
I ROOF PENTRATION
*---
j� ``` 5/a"0 LAG SCREW S.S. \SNAPNRA / �-itiii \�
ULTRA RAIL If'� `%' COMP SHINGLE ROOFING,TYP.
\ \ '
//1- 111, ►��
/ � ` ROOF DECKING,TYP.
" L'j
�` WOOD RAFTER SHOWN,
� SIMILAR AT OTHER
STRUCTURAL
MEMBER TYPES
1 "� lid"-1 2 "MIN.EMBEDMENT '
`� INTO WOOD MEMBER
11141144161
�- FLASHING SHOULD EXTEND
r TO END OF DOWNSLOPE
2 " PENETRATION DETAIL SHINGLE COURSE INSTALLED VIEW
1 "1 .1_____L
UR-40 RAIL 1 UR-60 RAIL
FOR USE WITH SNAPNRACK ULTRA SERIES RAILS
1-��� Sunrun South LLC DESIGNER: M.AFFENTRANGER SCALE: DNS DRAWING NUMBER: DESCRIPTION: REV:
Sna^
`"°"E"'A'°== DRAFTER: M.AFFENTRANGER ULTRA RAIL,ATTACHMENT DETAIL,FLASHED L
""" °""TM°^"�°°� "° " .W DATE: 5 Z SNR-DC-00340 i
" "` °""'"ww � " ®'":,;" '.� APPROVED BY: B.PETERS0N /�/ 019 FOOT TO RAFTER 1