Loading...
Report 4 2oz©a2ozio , i '`.gyp sW Agfio it W z3 , 'x"x8" v4°` 43,: . .�.-1 ' 'a";£ y A"xg xi .i., r::. y b 7; + gym? Al Portland General Electric Company r.1 , I 4GE 12/31/19 . 04 CONTACT: Tony Nguyen IN PHONE: 971-313-2892 �3 s CUSTOMER NAME: Starbucks Coffee ra W ADDRESS: 16200 SW PACIFIC HY TIGARD RECEIVE DR A JAN 2 1 202C ,t SDPM/ENGR: Travis Smallwood WR: M2707375 CITY OF TIGARD 4 ac PHONE: 503-672-5428 BUILDING DIVISION A�, 3-PHASE SECONDARY LINE-LINE FAULT CURRENT (RMS) rgr 4 LITCt' w TRANSFORMER DATA PAD MOUNT? YES . , XFMR Impedance (%): 2.12 % 3-PH SUBMERSI YES ql - .1 V ' TRANSFORMER SIZE: 150 KVA XFMR? NO Secondary VOLTAGE (L to L): 208 v WYE OH BANK? NO Ai,- rAtiA f VAULT--> VAULT ( or Pole --> Pole) SECONDARY Secondary Wire LENGTH: 0 Feet WIRE SIZE ,x$ ` i:i' Number of SECONDARY RUNS: 1 Run(s) of: HIM ° - Secondary WIRE Resistance R: 0.0180 Ohms/1000' a Secondary WIRE Reactance X: 0.0258 Ohms/1000' : VAULT ( or Pole) --> PANEL SECONDARY (or Svc Drop) fi : Service Wire LENGTH: 60 Feet WIRE SIZE 1 r * 4 Number of Service RUNS: 2 Run(s) of: 350 QX UG t Service WIRE Resistance R: 0.0600 Ohms/1000' =i Service WIRE Reactance X: 0.0330 Ohms/1000' . a„y, 3 5. .i ar 4. a 4 MAXIMUM FAULT CURRENT*: 14,701 Amps *Maximum fault current based upon transformers/conductors sized for 100% of electrical panel rating. R; �� Based on a panel size of: 400a A444 t To Print This Page: "Ctrl M"and choose"Print 3-Phase Data" Type 3R Current Transformer Hinge Cover Enclosures Data Sheet Construction • Enclosure and cover are fabricated from code gauge galvaneal steel, (see table) • Enclosure body has mounting holes on the back • .250-20 mounting studs are furnished on the enclosure body of most sizes for Utility current transformer mounting equipment, (see table) • Covers are secured to the body with a heavy-duty slip-hinge on the left side and mounting studs and wing nuts with Utility sealing hole provisions on the opposite side • Covers are completely removable when in the open position i 'l , • Fixed door handles(new design not shown) • Ground lug is mounted on the inside bottom end of each cabinet Finish 4 • Wash and phosphate undercoat • ANSI 61 gray acrylic electrocoat finish , Accessories • Touch-up paint • See Accessories section Application • Designed to house current transformers • Used as wiring boxes,junction and pull boxes • Protects against falling rain, sleet and external ice formation Standards • UL 414 listed, Type 3R • Conforms to NEMA standard for Type 3R • IEC 60529, IP32 Enclosure Enclosure Size Height x Width x Depth AxBxC D E F G Catalog Number in. mm Gauge in. mm in. mm in. mm in. mm 203611 HRTCT 36.00x20.00x11.00 914x508x279 14` - - - - - 243011 HRTCT 30.00x24.00x11.00 762x610x279 14 12.00 305 8.00 203 8.00 203 - - 244811 HRTCT 48.00x24.00x11.00 1219x610x279 14 21.00 533 -8.00 203 8.00 203 303611 HRTCT 36.00x30.00x11.00 914x762x279 12 15.00 381 7.00 178 8.00 203 8.00 203 304811 HRTCT 48.00x30.00x11.00 1219x762x279 12 21.00 533 7.00 178 8.00 203 8.00 203 363611 HRTCT 36.00x36.00x11.00 914x914x279 12 15.00 381 10.00 254 8.00 203 8.00 203 364811 HRTCT 48.00z36.00x11.00 1219x914x279 12 21.00' 533 10.00' 254 8.00 203' 8.00 203 Consult the local Utility for area acceptance. 1111. Notes: B-Line Systems can provide special sizes,finishes and other modifications. COOPER B-Line 91 Consult the factory for your special requirements. Type 3R Current Transformer Hinge Cover Enclosures Illustration Sheet B C { - E F — G - dslip hinge o 0 3- cover mounting o stud with utility sealing hole provision 0 0(32) 0 slip hinge A 1.75 (omit where"A" (44) .250 20 device 6.00D A is less than 48) mounting stud o (152) B-1.25 0.38 (l0) mounting hole(4PL) —0 0 _J 11- ground lug Side View Front View (cover removed) (cover removed) 92 COOK B-Line Notes: Dimensions are in inches.Millimeters shown are for reference only. Data subject to change without notice. Utility/ Current Transformer Metering - 800 Amp/ 50K AIC/ Bussed Current Transformer Enclosure APPLICATION • For remote metering when main service is 201-800 amps • For use with utility supplied bar type current transformers that meet ANSI C 12.11 • CON STR U CTION . 4.. lit, r .* • Type 3R construction • Removable hinged door with sealing provision • Cover has newly designed fixed handles(not shown) 4 STAN DARDS • UL 414 listed,complies with ANSI C 12.7 FIN ISH • ANSI 61 gray acrylic electrocoat finish 803 HEE Overhead/ Underground—Surface Mount 03rnucroa LUG R.ReACE UMEN906(ItOES) CATALOG AIC A.Ipaar V SRV10E PHASE atZUCTCR NEUTRAL HU�G1-IT WIDTH DiH NUN188 RATING MAX. Gaff. OLTAC� TYPE LINE/Loa) CXJDUCTCR (H) (W) (D) 803 HEE 50K 800 800 800 304W STUDS STIRS 48 3 12 C 1 a y Utility/ Current Transformer Metering t2 400-800 Amp/ 10K & 50K AIC/ Bussed Current Transformer Mounting Base L 0 • 1 E ' APPLICATION 7 C 4' ' . • For use with CT rated metering enclosures El V 60 {.I 0 , , �l' i • For use with bar type CT that meet ANSI C12.11 N --.. • t/2"studs on 13/4"centers-line& load __ STAN DARDS al n • UL 414 listed,complies with ANSI C12.7 '%� . j FINISH it 7 i lS ss s `' • ANSI 61 gray acrylic electrocoat finish (mounting plate only 6019A 6019HA Overhead/ Underground—Surface Mount 0 Noucrm LW RAC CATALOG I NC rcFCT. At1PACTr VOLTAGE SERACE PHasECXJDUCTCR NEUTRAL Tv"N.SZE NuraEER 1 RATING P nsaas QM. , Max. TYPE LINE LOAD CONDUCTOR ECLCSURE 6019A 10K 2 400 1t70 10a 30 3W ST1C6 STUDS STAS 24" 6O19HA 50K 2 400 80D 10a303W STIRS STUDS STAB 24' 6018E 10K 2 800 MO 10a 30 3W STUJ6 STUDS STUC6 24" 6019HE 50K 2 800 600 10a303W -STAB SRLE Sil S 24' 6067A 10K 3 400 800 30 3W or 4W STUDS SILOS STAG 30" 6067M 50K 3 400 600 333Wcr4W STUDS STUDS STU:6 30' 6067EE, 10K 3 800 600 30 3Wa 4W STUDS STAS STAB 30" 60671f 50K 3 MO 600 303Wor4W 'STUDS STAB STAB 30" 1 1U riOO!'• R B-Line Data subject to change without notice.Consult local utility for area acceptance.All dimensions in inches. Utility/ Current Transformer Metering 400-800 Amp/ 50K AIC/ Bussed Current Transformer Mounting Base APPLICATION .��';: • For use with CT rated metering enclosures • For use with bar type CT that meet ANSI C 12.11 4; eaLkt, ; • Integral mechanical lugs-line&load P :y STANDARDS mom. • UL414listed,complies with ANSI C12.7 } FINISH *4* +►** • ANSI 61 gray acrylic electrocoat finish (mounting plate only) 6067 HEEL Overhead/ Underground—Surface Mount Ccnoucra3 LLG FINCE CATALOG AC #cF C.T. Pn,PAOTY VaTac,E SITN10E LUG WIRE Rave f k uan RA11 PROVISOS MAX. Cora. TrPE LINE&LOAD 60191W.. 531( 2 400 400 600 10or 30'3W (1)4 ANG-6001(amil or(2)1/0-250kcmil 6019 HH. : 50K 2 800 100 600 10or 303W (3)4 ANG-6001cmil or(6)1/0-2E010ril 606714 L 50K 3 400 400 600 304W (1)4 AWG-600kanil or(2)1/0-250kanil 60671fEL 50K 3 800 800 803 304W (3)4 AW3-600krril or(6)1/0-250karil C APPLICATION - • For use with CT rated metering enclosures • For use with bar type CT that meet ANSI C12.11 -- , 4;41 • Studs line side lugs load side C ` • 1/2"studs on 13/4"centers CD , - lD STAN DARDS • UL414listed,complieswithANSIC12.7 �'� # � FINISH • ANSI 61 gray acrylic electrocoat finish (mounting 6067 HEELS plate only (Q Overhead/ Underground—Surface Mount CamucrcA LLG Rarer CYTALDG PJC #CF CT. AnoPaarr VaTnG< Si3RVICE LUG WIRE R NUMBER{ RATING PROVISOS MAX. Carr. T(PE LINE LOAD 6019 HALS `.' 50K 2 400 400 COO 10or 303W STUDS (1)4 AWG-600kanil or(2)1/0-250karil 6019 HIS 90K 2 600 800 600 10a 3PY3W SRAS (3)4 AWG-600I(anil or(6)1/0-250 aril 6067 H6LS 50K 3 400 400 E00 304W STUDS (1)4 AWG-600kar it or(2)1/0-250karil 6067 HAS 501( 3 800 003 600 304W STUB (3)4 AW3-600knril ar(6)1/0-250karil Data subject to change without notice.Consult local utility for area acceptance.All dimensions in inches. COOgR B-Line y 1 y Single Meter Sockets CT Rated With Test Switch Bypass Provision Application -^ - '''' • Test switch section under separate cover 41 • Test switch perch included �� • Receive ANSI C12.10 watthour meters t • Overhead and underground feed (see chart) • Surface mount �}� Construction �1;■ � 'r • Ring type `�.�r c �� .. NEMAType 3R • ANSI 61 gray E-coat finish • Aluminum snap ring included ice. #.,.b.. .: Standards 121413(closed) 121413(open) • UL 414 Listed • ANSI C12.7 • EUSERC 339 Accessories • AW Hub • Screw Type Ring-25016D Part/UPC Catalog Amp Service Connections Number Number Rating Jaws Type Access Line Load Neutral 78205146000, 12144 20 4 10 OH/UG #14-#10 114 #10 #14-#10 78205146010 12145 20 5 10 OH/UG #14-#10 #14-#10 #14-#10 78205146020 12146 20 6 10 OH/UG #14-#10 #14 #10 #14-#10 78205144640 12148 20 8 10 or 30 OH/UG #14-#10 #14-#10 #14-#10 78205144650 121413 20 13 30 OH/UG #14 #10 #14-#10 #14-#10 78205144065 121415 20 15 30 OH/UG #14-#10 #14-#10 #14-#10 78205146070 1214208* 20 8 10 or 30 OH/UG #14 #10 #14 #10 #14-#10 78205146060 1214213* 20 13 30 OH/UG #14-#10 #14-#10 #14-#10 78205180265 1214215* 20 13 30 OH/UG #14-#10 #14-#10 #14 #10 Part/UPC Catalog Overall Dimensions Top Knockout Number Number Height Width Depth Provision Layout 78205146000 12144 20" 12" 45/t" AW Hub Fig.1 78205146010 12145 20" 12" 45/e" AW Hub Fig.1 78205146020 12146 20" 12" 45/8" AW Hub Fig.1 78205144640 12148 20" 12" 45/e" AW Hub Fig.1 78205144650 121413 20" 12" 45/e" AW Hub Fig.1 78205144065 121415 20" 12" 45/e" AW Hub Fig.1 78205146070 1214208* 20" 243/8" 45/e" AW Hub Fig.2 78205146060 1214213* 20" 243/e" 45/e" AW Hub Fig.2 78205180265 1214215* 20" 243/e" 45/e" AW Hub Fig.2 n E "Not EUSERC 339 compliant. co 2 B—Line Data subject to change without notice.Consult local utility for area acceptance.All dimensions are in inches. by E,T•N 69 Meter Mounting Equipment Utility/ Current Transformer Metering • 20 Amp/ Current Transformer Rated With Test Switch Provision APPLICATION • Single meter position _ • Designed to receive watthour positions that meet ANSI C12.10 • For use with separate CT enclosure • Overhead or underground feed CON STRUCTION • Type 3R construction • Test switch provisions • Available with installed pre-wired test switches—add prefix"W"to catalog number • AW hub provision • Snap type sealing ring included • Ring style STAN DARDS • UL 414 listed,complies with ANSI C12.7 FIN ISH • ANSI 61 gray acrylic electrocoat finish 1 21 41 3 ACCESSORIES • Screw type sealing ring— catalog#25016D • AW hubs • Steel or clear lexan covers for socket openings C w overhead/ Underground—Surface MountOlCuCTORLuG RANGE DMBa0NS INas ) CATALOG` MAC AmpAaTy SERVICE NUMEHi HUB CI;CUIZING FIQJRE HBCHc WIDTH DEPTH NUMB Dscoi r MAX. WIT. VaracE TYPE CFJAws PaoV. AL TERMINALS TaoiruL NuoBEIT (H) (W) (D) 4E! 2 12144 NCI`E 20 20 600 10 4 AW 14 AWG-10 MG 14 ANG-2/0 AWG Rg.1 20 12 4% a L 12145 NOTE 20 20 630 10 5 AW ; 14 AVtG-10NAG 14 AWG-2/0 AM Rg.1 20 12 4%' CD 12146 NOTE 20 20 600 10 6 AW 14 Asti-10 AWG 14 ANG-2/0 AWG Rg.1 20 12 4% 12148 10E 20 20 E00 10or 30 8 AW 14 AWG-10 AWG 14AWG-2/0AWG Fig.1 20 12 4`4 U O 121413 NOT 20 20 600 30 13 AW 14 AWG-10 AWG 14 RAG-2/0 AWG Rg.1 20 12 4% 121415 NONE 20 20 633 30 15 AW 14 A1AG-10 AWG= 14AWG-2/OAWG Rg.1 20 12 4% �y C reversible test switch perch allows test switch instaftlion at two heights (13 7 3/16 Diameter Hole (4 places) #1032 Tapped Holes (8 places) I 1,/4 3 v. 3 1/4 3 1/4 41/4 f 41/4 11 7/6 y 13/16 h- 1/4 Offset Test Switch Perch 0 0 COOPER B-Line Data subject to change without notice.Consult local utility for area acceptance.All dimensions in inches. Utility/ Current Transformer Metering 20 Amp/Current Transformer Rated With Test Switch Provision .. W r1 •HA AP p AP p AP AP AP AP Knockouts — Conduit Sizes Fig. 1 3Y4 2a'4 2V4 AP=1 %"-1"-3/4"-1/z" C `—' HA=AW HUB 0�` n 0 3 C CD rt Test Switch Perch Instructions (D CD -5 To offset test switch perch so that additional space is syllable for the use of a test switch cover,see instructions below. (Q Screw Perch 1.Remove(4)screws that hold the perch �7 Enclosure to the enclosure(see Drawing 1) / Drawing 1 Perch 2.Flip perch over as shown(see Drawing 2) Drawing 2 Screw 3.Now use the screws you removed In ,(Perch step one and screw the perch to the Enclosure enclosure,torque screws to 35 i n/lbs. (see Drawing 3) Drawing 3 Data subject to change without notice.Consult local utility for area acceptance.All dimensions in inches. COOgR B-Line 1 0 t E A i Detail Bill of Material Page 1 of 1 Project Name: Starbucks Tigard Town Square Negotiation No: J1891203X9K1 Powering Business Worldwide General Order No: Alternate No: 0000 Item No. :,Qty Product Description 1 Panelboards 42 Circuits,400A,Fully Rated,208Y/120V 3Ph 4W,Copper Bus, 22k AIC,400A,3P DK Main Breaker[Bottom Fed],Flush Mounted Catalog No P1A400BB42CH01 Designation BRANCH PANEL A Qty List of Materials 1 400A,3P DK Main Breaker 1 400A,Through-Feed Lugs 2 50A,3P QBHW-H Branch Breaker 3 1 P QBHW Branch Provision Only 1 20A,2P QBHW Branch Breaker 2 40A,2P QBHW Branch Breaker 21 20A, 1 P QBHW Branch Breaker 1 30A, 1 P QBHW Branch Breaker 5 20A, 1 P QBHGFT Branch Breaker,GFCI-5mA 1 Copper Main Bus,400 Amps 1 Std,Bolted Al Ground Bar(Al/Cu Cable) 1 Panel Nameplate-White with Black Letters 1 Service Entrance Panel 1 Type 1 Enclosure:EZB2072R 1 EZ Trim, Door in Door,Concealed Hardware Item No. Qty Product ' Description 1 Panelboards 54 Circuits,400A,Fully Rated,208Y/120V 3Ph 4W,Copper Bus, 22k AIC,400A,Main Lugs Only[Top Fed],Flush Mounted Catalog No P1A400LT54CH01 Designation BRANCH PANEL B Qty List of Materials 1 400A,Main Lugs Only 23 20A, 1 P QBHGFT Branch Breaker,GFCI-5mA 4 40A,2P QBHW Branch Breaker 1 50A,2P QBHW Branch Breaker 15 20A, 1P QBHW Branch Breaker 6 1 P QBHW Branch Provision Only 1 Copper Main Bus,400 Amps 1 Std.Bolted Al Ground Bar(Al/Cu Cable) 1 Panel Nameplate-White with Black Letters 1 Type 1 Enclosure:EZB206OR 1 EZ Trim,Door in Door,Concealed Hardware Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required,drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly,andlor if shipment is delayed for any reason,the price of the order will increase by 1.0%per month or fraction thereof for the time the shipment is delayed. Jake Frachiseur Platt Elec Sply Inc Eastside Or 01/20/2020 3:38 PM Eastside Ofc 322 S.e.Taylor Portland,OR 97214-2157 General Information (Section 1 of 1) Blank Cover Service Voltage: 208Y/120V 3Ph 4W Enclosure: Type 1 Bus Rating&Type: 400A Copper Neutral Rating: 400A 3 inches Ground Bar: Std.Bolted Aluminum,Al or Cu cable S.C.Rating: 22kA.I.C.Fully Rated Through-Feed Lugs 400A Main Device Type: Main Breaker-Bottom Cable Entry Main Terminals: Mechanical-(1)2/0-500 kcmil(Cu/AI) 1 QBHW3050H QBHW3050H 2 Neutral Terminals: Mechanical-(2)#4-500 kcmil(Cu/AI) — — Through-Feed Lugs: Mechanical-(2)#4-500 kcmil(Cu/AI) 3_ _4 Box Catalog No.: EZB2072R 5 6 Trim: EZ Trim,Door in Door,Concealed Hardware(EZT2072F) 7 QBHW1020 QBHGFT102( 8 9 QBHW1020 QBHW1020 ic Flush Mounted 11 QBHW1020 QBHW1034__12 Box Dimensions: 72.00"[1828.8mm]H x 20.00"[508.0mm]W x 5.75"[146.1 mm]D 13 QBHW1020 QBHW202C,_14 Min.Gutter Size: Top=5.5"[139.7mm]Bottom=5.5"[139.7mm] 1s QBHW102C 18 Left=6.0"[152.4mm]Right=6.0"[152.4mm] 17 QBHW204C QBHW2040k_1E 19 2C Panel ID Nameplate: (1)BRANCH PANEL A Type: Plastic,adhesive-backed (2)208Y/120V 3Ph 4W 21 QBHW102C QBHW1020 22 Color: White with Black Letters (3) 23 QBHW102c QBHGFT102( 24 25 QBHGFT102( QBHW1020 29 UL 27 QBHW10201/4,QBHW102C 25 Service Entrance Label ***Non-Interchangeable Main Device*** 29 QBHW1020 QBHW1020 3C Trim Lock:Standard Lock&Key(Keyed WEM2) 31 QBHGFT102( QBHGFT102( 32 Circuit Directory:Plastic Sleeve with Card 33 QBHW1020 QBHW1020 34 Main Circuit Breaker Trip Type:Thermal-Magnetic. 35 QBHW1020 QBHW102C 35 Seismic Label(IBC/CBC Seismic Qualified). 37 QBHW1020 QBHW1020 38 Heat Loss-Watts(Est.)=241 39 QBHW1020 PROV 4C Weight lbs(Est.)=188 41 PROV PROV 42 Main Breaker 400A DK3400W, Vert Mtd. Device Modifications: Ref# Description Branch Devices Qty Poles Trip Frame Amps kAIC 2 3 50 QBHW 100 22 21 1 20 QBHW 100 22 1 1 30 QBHW 100 22 5 1 20 QBHGFT 100 22 2 2 40 QBHW 100 22 1 2 20 QBHW 100 22 3 1 PROV Main Devices Qty Poles Trip Frame Amps kAIC 1 3 400 DK 400 22 Notes: The information on this document is PREPARED BY DATE created by Eaton Corporation.It is JAKE FRACHISEUR 1/20/2020 Eaton disclosed in confidence and it is only to be used for the purpose in which it is APPROVED BY DATE JOB NAME Starbucks Tigard Town Square supplied. DESIGNATION BRANCH PANELA VERSION TYPE DRAWING TYPE 1.0.0.32 PRL1a Customer Approval NEG-ALT Number REVISION DWG SIZE G.O. ITEM SHEET J1891203X9K1-0000 0 A 1 of 1 General Information (Section 1 of 1) Main Lugs Only Service Voltage: 208Y/120V 3Ph 4W Enclosure: Type 1 400A Bus Rating&Type: 400A Copper Neutral Rating:400A Ground Bar: Std.Bolted Aluminum,Al or Cu cable 1 QBHGFT102(( QBHGFT102( 2 S.C.Rating: 22kA.I.C.Fully Rated 3 QBHGFT102( QBHGFT102( 4 5 ,QBHGFT102( QBHGFT102( 6 Main Device Type: Main Lugs Only-Top Cable Entry 7 QBHW2o4a`_8 Main Terminals: Mechanical-(2)#4-500 kcmil(Cu/AI) 9 ,QBHGFT102( 1c Neutral Terminals: Mechanical-(2)#4-500 kcmil(Cu/AI) 11 QBHW1020 QBHW1020 12 Box Catalog No.: EZB206OR 13 QBHGFT102( QBHGFT102( 14 Trim: EZ Trim,Door in Door,Concealed Hardware(EZT206OF) 15 QBHGFT102`QBHGFT102( ,e 17 QBHGFT102( QBHGFT102( 1E Flush Mounted 19 ,QBHGFT102(/QBHGFT102( 2C Box Dimensions: 60.00"[1524.0mm]H x 20.00"[508.0mm]W x 5.75"[146.1 mm]D 21 QBHGFT102( QBHW1020 22 Min.Gutter Size: Top=5.5"[139.7mm]Bottom=5.5"[139.7mm] 23 QBHW1020 QBHW1020 24 Left=6.0"[152.4mm]Right=6.0"[152.4mm] 25 QBHW1020 QBHW1020 2E 27 QBHGFT102C QBHW205\ 2E Panel ID Nameplate: (1)BRANCH PANEL B 29 QBHGFT102( 3C Type: Plastic,adhesive-backed (2)208Y/120V 3Ph 4W iBus Support I Color: White with Black Letters (3) 31 ,QBHGFT102( QBHGFT102L 32 UL ***Non-Interchangeable Main Device*** 33 QBHGFT102( QBHW204Ck_34 35 QBHW2040 3E Trim Lock:Standard Lock&Key(Keyed WEM2) 37 QBHW102C 3E Circuit Directory:Plastic Sleeve with Card 39 QBHGFT102( QBHW102C, 4C Seismic Label(IBC/CBC Seismic Qualified). 41 QBHW1 020 QBHW1020 42 Heat Loss-Watts(Est.)=211 43 QBHW1 020 QBHW1 020 44 Weight-lbs(Est.)=224 45 C, BHW1020 QBHGFT102( 4E 47 QBHW1020,,, PROV 4E 49 QBHGFT102( PROV Sc 51 PROV PROV 52 53 PROV PROV 54 Blank Cover 5 inches Device Modifications: Ref# Description Branch Devices Qty Poles Trip Frame Amps kAIC 23 1 20 QBHGFT 100 22 4 2 40 QBHW 100 22 1 2 50 QBHW 100 22 15 1 20 QBHW 100 22 6 1 PROV v. Notes: The information on this document is PREPARED BY DATE created by Eaton Corporation.It is JAKE FRACHISEUR 1/20/2020 Eaton disclosed in confidence and it is only to be used for the purpose in which it is APPROVED BY DATE JOB NAME Starbucks Tigard Town Square Supplied. DESIGNATION BRANCH PANEL B VERSION TYPE DRAWING TYPE 1.0.0.32 PRL1a Customer Approval NEG-ALT Number REVISION DWG SIZE G.O. ITEM SHEET J1891203X9K1-0000 0 A 1 of 1