Plans (2)
OFFICE COPY INSTALLATION NOTES SITE INFORMATION - WIND SPEED: 97 MPH AND SNOW LOAD: 10 PSF AERIAL VIEW 1.STRUCTURAL ROOF MEMBER LOCATIONS ARE SR. NO. OF ARRAY AREA ROOF FRAME FRAME MAX RAIL OVER AZIMUTH PITCH ROOF TYPE ATTACHMENT FRAME TYPE L. ESTIMATED AND SHOULD BE LOCATED AND NO MODULES (SQ. FT.) EXPOSURE SIZE SPACING SPAN HANG 3 VERIFIED BY THE CONTRACTOR WHEN LAG BOLT J PENETRATION OR MECHANICAL ATTACHMENT TO MP 01 180° 20° 14 250.4 COMPOSITION FLASH FOOT 2 ATTIC PRE-FABRICATED TRUSSES 2 X 4 2'-0" 4'-0" 2'-0" ► THE STRUCTURE IS REQUIRED. SHINGLE 2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. CITY OF TIGARD 3.LAGS MUST HAVE A MINIMUM 2.5" THREAD plans + EMBEDMENT INTO THE STRUCTURAL MEMBER. ApprovedREVIEWED FOR CODE COMPLIANCE 4.ALL PV RACKING ATTACHMENTS SHALL BE shall be on job site, BY ROW BETWEEN THE ROOF FRAMING Approved: [Vi MEMBERS AS NECESSARY. O'TC: [ i w 5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE / �f r" THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL Permit #: O,S �i02.0 ' 06 d i�! SHALLGREAT COND THANUCTORS 40'. 01�1.1,0 S� 0 th9t,,� ST RECEIVED 6.ALL CONDUCTORS AND CONDUITS ON THE ROOF Address: SHALL BE MINIMUM 2.5" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH Suite #: MODULES AND RACKING). I3}: Dat@� ��j� _�f r�'I/1 JAN 1 5 2020 7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY 'Prk ` . .02A PLUMBING, MECHANICAL OR BUILDING ROOF CITY OF TIGARD VENTS. BUILDING DIVISION ROOF ACCESS PATHWAYS AND SETBACKS: IFC 605.11.1.2.2 HIP ROOF LAYOUTS PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS WITH HIP ROOF LAYOUTS SHALL BE Smartenergy today' LOCATED IN A MANNER THAT PROVIDES TWO, SOLAR 3-FOOT WIDE ACCESS PATHWAYS FROM THE EAVE TO THE RIDGE ON EACH ROOF SLOPE WHERE PANELS AND MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE AT A LOCATION ON THE k BUILDING CAPABLE OF SUPPORTING THE FIRE CONTRACTOR:SMART ENERGY TODAV,INC LICENSE NO:CCB 198547 FIGHTERS ACCESSING THE ROOF. ELECTRICAL CONTRACTOR:C1151 IFC 605.11.1.2.3 SINGLE-RIDGED ROOFS /// /./d, �/ ////�/////� CUSTOMER INFORMATION PANELS AND MODULES INSTALLED ON GROUP R-3 v � BUILDINGS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO, I � � _;_ : •_-_.._...+,- _-_ ._ __.., ___.. _ - __*._..___.,*.,_.. ___ NAME:BRUCE ALLERT 3-FOOT WIDE ACCESS PATHWAYS FROM THE EAVE / i f I TO THE RIDGE ON EACH ROOF SLOPE WHERE E C PANELS AND MODULES ARE LOCATED. ' j i 1 �_ .-,_ __ ., ._ ADDRESS:9210 SW OMARA ST,TIGARD, IFC 605.11.1.2.4 ROOFS WITH HIPS AND / ; OR 97223 VALLEYS ' PANELS AND MODULES INSTALLED ON GROUP R-3 ! j ♦ • ° 1 45 25'18.7"N 122°46'18.0"W BUILDINGS WITH ROOF HIPS AND VALLEYS SHALL ! APN: 2S102DC00508 NOT BE LOCATED CLOSER THAN 18 INCHES TO A HIP OR A VALLEY WHERE PANELS/MODULES ARE TO E AHJ:OR-CITY OF TIGARD BE PLACED ON BOTH SIDES OF A HIP OR VALLEY. WHERE PANELS ARE TO BE LOCATED ON ONLY ONE SIDE OF A HIP OR VALLEY THAT IS OF EQUAL UTILITY:PGE LENGTH, THE PANELS SHALL BE PERMITTED TO BE �4'-- PLACED DIRECTLY ADJACENT TO THE HIP OR PRN NUMBER:SET-007250 VALLEY. EXCEPTION: THESE REQUIREMENT SHALL NOT VALIDITY OF PERMIT ALUMINIUM RAILS • APPLY TO ROOFS WITH SLOPES OF TWO UNITS THE ISSUANCE OF A PERMIT a ILLUMINE VERTICAL IN 12 UNITS HORIZONTAL (2:12) OR BASED ON CONSTRUCTION ARRAY MP-01 w. LESS. DOCUMENTS AND OTHER Because quality matters DATA SHALL NOT PREVENT 2 X 4 PRE-FABRICATED THE CODE OFFICIAL FROM TRussEs@ 2' o"SPACING LIABILITY REQUIRING THE CORRECTION MOUNTING DETAIL The City of Tigard and its OF ERRORS.ORSC 105.4 / \ DESIGNER/CHECKED BY: employees shall not be --, N -I-- RK/BH responsible for discrepancies + which may appear herein. OFFICE COPY SCALE:AS NOTED REV:A SCALE:1"=10'-0" DATE:12/31/19 M-1 DEAD LOAD CALCULATIONS ATTACHMENT DETAIL-FLASH FOOT 2 MODULES DATA BOM QUANTITY LBS/UNIT TOTAL WEIGHT AXITEC SOLAR AC-310MH/1205 (LBS) MODULES 14 40.79 571.06 SOLAR MODULE FLASH FOOT 2 MODULE DIMS 65.94"x39.06"x1.38" MID-CLAMP 24 0.050 1.20 6" MAX LAG SCREWS 5/16"x3.5":2.5"MIN END-CLAMP 8 0.050 0.40 RAIL EMBEDMENT RAIL LENGTH 93 0.680 63.24 "� ,�- SPLICE BAR 6 0.400 2.40 FLASHING •1 FLASH FOOT 2 26 1.88 48.88 J s� (— TOTAL WEIGHT OF THE SYSTEM (LBS) 687.18 / TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 250.41 WEIGHT PER SQ. FT.(LBS) 2.74 WEIGHT PER PENETRATION (LBS) 26.43 STAINLESS STEEL 5/16" HANGER BOLT 2.5" EMBEDMENT PILOT HOLE REQUIRED -~'` L ----" J -L-rar+energy today' SOLAR MID-CLAMP AND END-CLAMP ANATOMY ROOF FRAMING DETAILS 5/16" X 3.5" LAG SCREW 1 BOLT PER PENETRATION CONTRACTOR:SMART ENERGY TODAY,INC LICENSE NO:CCB 198547 MODULE MID CLAMP END CLAMP =COMPOSITION SHINGLE ROOF ELECTRICAL CONTRACTOR:C1151 MODULE MODULE -- RUSSES ©2 2.OTSPACI G CUSTOMER INFORMATION f V&A� AvA--��N• ___m!__m_liI._ff1ff0 NAME:BRUCE ALLERT W4F��AYAYA WAV•A•••i IAt����;;;Alli_ VOOpOA YAVAVAVAVA = ADDRESS:9210 SW OMARA ST, TIGARD, LOAD BEARING WALL OR 97223 SCALE:NTS GROUNDING DETAILS 45°25'18.7"N 122°46'18.0"W APN: 2S102DC00508 MODULE TO MODULE & MODULE TO RAIL GROUNDING LUG RAIL TO RAIL AHJ:OR CITY OF TIGARD UTILITY:PGE MID CLAMP PRN NUMBER:SET-007250 ASSEMBLY SELF-DRILLING SCREW IRONRIDGE RAIL .0 ILLUMINE i MODULE •,. FRAME Because quality matters RAIL STRUCTURAL DETAIL DESIGNER/CHECKED BY: GROUNDING MID-CLAMP T-BOLT RK/BH SCALE: NTS SCALE: NTS IRONRIDGE INTERNAL SPLICE SCALE:AS NOTED REV:A DATE:12/31/19 M-2 SINGLE Lir. vr OPTIMIZEK P320 DC5» �D_ 0 T VOLTAG : 48OV VDROP 240x 1 4,ALL CoC ISE NO TION MODEL g VDC INVERTER STRING VOLTAGE:VOC UNLESS OTHERW SIZES CONFORM SPECIFICATION TO MSP KERIFUSE MODULE 5 AXITEC SOLAR MAX INVERTER G VOLTURRENT ® pV AC DISCONNECT S,gREA SECTION. ELECTROD 1205 MIN INPUT VOLTAGE 4S VDC =0.10% NEC 240.6 CODE 10 TIONS qC 31010WMH/ VOLTAGE MAX SHORT CIRCUIT ° 21A x1.2x5X2GROUNDING NEC 250•66' 10 1 SPECIFICATIONS MODEL 310W MAX INPUT 11 ADC CURRENT VDROP�O_ 24 6.AC SIZED PER CORRCFCT NVERTER- SO�pREDGE TECHNOLOGIES MAX INPUT CURRENT OPERATING UM : "5° CONDUCTOR us(2 15 ADC TEMPERATURE 40.o1V TURF MINIM ° NEC 690 3 ( ) SE5000H MODULE POWER UP RTC DATA: TEMPERA 7.ASS OTT EASED ON MAXOUTPUT CURRENT MAXIMUM : 32 ADJUSTMEN 5000W CIRCUIT VOLTAGE:V�C CALCULATIONS EXTREME TORE OR IS TEMPERATURE NEB OPEN TEMPERA FACT ON NG CORRECTION EXTREME $AMgIFNT IS BASED MAX POWER VOLTAGE.VmP TEMPERATURE = 0 g60 THE UTILITY FACTOR • f CURRENT ° 0.29%/°C))o °C87 NOTE; FAR FROM 310.15(g)(2)(C) CORRECTION I" SHORT CIRCUIT VOLTAGE:ISc VocMAX=(1+( 5°C 25 °)(25°C)(-0.39/°/ )) SYSTEM VOLTAGE VMPHOT-(1+(32°C+29 C" AC DISCONNECT IS 5' TED EFFICIENCY 9ER NECARE SIZED PER WIRE • MAX POWER CURRENT:ImP PER N 690.7. CURRENT 4SOV DOCTORS 310.16. AMPAC TABLE NEC )LTAGE AMPACITY '9' yp 240V 1PH 60HZ SOLAR EXISTING 120/ ` METER#:PGE 249g8966IN (EXTERIOR) ''',, �` 310MHI120S, TODAY,INC UTILI (N)AXITEC SOLAR AC- CONTRACTOR;SMART ENERGY MODULES coNTRA C1ISI GRID 31oW LICENSE NO'.CCB 19854� ELECTRICAL CONTRACTOR. pV MODULES 14 MODULES WIRED R (E)200A END FED �(� IN(1)SERIES OF 14 MODULES CUSToME MAIN PANEL (N)SOLAREDGE TECHNOLOGIES ECHS O W IFS US(240V), (N)JUNCTION SESOOOH 1 zTINVERTER •0 OR EQUI 11112 2 NAME:BRUCE ALLER Y/ (E)100A SUB t. .1 Wl PANEL (N)60A AC TIGARD, o�\ pISCONNECT _ 3 SOLAREDGE POWER DMARA ST, IleOPTIMIZERS pDDRESS:9210 SW o m _ 3 OR 97223 DC DISCONNECT&AFCI W WILOAD RATED COMPLIANCE) N 122°46118'01 30A PV BREAKER pG222URB OR SHUTDOWN 45°25'18.7 C00508 EATON (RAPID 2S102D FEEDER AT OPPOSITE END EQ ON PV SYSTEM ACOPEN (INTERIOR) APN 70A SUB OF THE BUS BAR DISCONNECT SWITCH CITY OF TIGARD BREAKER ELECTRO D (INTERIOR) NON FUSED VISIBLE MAIN BREAKER RATINLE•20 CKFEED 40A E�ECT0.0DE IS AH]:OR- 60A,120/240V 2P BA (INTERIOR) _ (INTERIOR) NOTE: 200A, _40A=>ALLOWAB 1 25) MAIN PANEL RAT AX: 00A, A- 5°25'iY:PGE 120%RULE. ( CONTINUOUS LOAD( • SET-007250 GROUND CALCULATIONS: ION=INVERTER 0/P I X PRN NUMBER: CONDUIT SCHEDULE COPPER OCPD CALCU�A' REQUIREMENTS• (1) lOAWG BARE O DESIGNED I TE BREAKER= 30A s • THHN/THWN"2 INVERTER 26 25A= >30A PV BREAKER 705.12(g)(2) ILLUMINE NONE (1) 10AWG =21X1.25= 40A= MEETS THE CONDUCTOR BACKFEED INTERCONNECTION a THHNITHWN 2 ALLOWABLE INTERCON quality Matter CONDUIT SIZE (2) 10AWG pV WIRE NONE (1) 10AV`/G THE DESIGNED Because U TAG ID NONE THHN/THWN"2 THHN/THWN 2 • (2) 10AWG (1) lOAWG E UIV THHNITHWN-2 TING:90°C SINGLE LINE DIA�7RA 3/4"EMT OR Q (2) 10AWG CALCULATIONS TEMPERATURE RA UCTOR AMPACITY CHECK © E UIV ELECTRICAL CA1- TION DERATED CONv 23 20A ELE CALCULATIONS:-MATERIAL:COPpFR& 314"EMT OR Q CALCULA © DC WIRE CORRECTED AMPACI v�23.20A�v BY: o.5s © ,�� DESIGNER/CHECKED ®�a"1010 40 v 0.71 © 0.8 ING EQUX Isc( >X #OF REQUIRED CONDUCTOR AMP© RK/BH OF FOLLOW X Isc(A) ©v�®©®� REV' TIONS BASED o PER 690•$(A)(1) X 125% PER TA©v©®©©�® ° CHECK SCALE:AS NOTED SIZING CALCULA ©® TORE RATING:90 C E . 125/o PER 690.a(A)(1) DC WIRE AMPACI CURRENT TORE DEBATE v TEMPERA ED CONDUCTOR MAX B (2)(a) TEMPERA DERATED CONDUCTOR AMPAC 34 BOA •REQUIRED STRINGS X 11111111111 CALCULATIONS:-MATECORRC TED A & CALCULATION v DATE:12/31/19 PARALLEL , _MAX. . CURRENT PERA690.(:AMPACITY AMpACITY 2) < CALCULA _ _ ,-�r.�nUCTOR � �.a0.8(B)(2)( AC WIRE CORRECTED AMPACITY .i4,80A WARNING PLACARD PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH -----1 RATED AC OPERATING CURRENT 21.00 AMPS AC ELECTRIC SHOCK HAZARD AC NOMINAL OPERATING VOLTAGE 240 VAC WARNING . I THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE • ■ ENERGIZED LABEL LOCATION AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION [PER CODE: NEC 690.54] POWER TO THIS BUILDING IS ALSO DC DISCONNECT,INVERTER [PER CODE: NEC henin inverter WARNING SUPPLIED FROM THE FOLLOWING [To be used when inverter is ungrounded] INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS SOURCES WITH DISCONNECTS LOCATED AWARNING OVER-CURRENT DEVICE ELECTRIC SHOCK HAZARD LABEL LOCATION AS SHOWN DO NOT TOUCH TERMINALS POINT OF INTERCONNECTION �� (PER CODE: NEC 705.12(D)(7) TERMINALS ON BOTH LINE AND LOAD SIDES MAY Q� -- [Not Required if Panel board is rated not less than sum of ampere BE ENERGIZED IN THE OPEN POSITION ratings of all overcurrent devices supplying it] \ I / DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR CAUTION: SOLAR CIRCUIT \ // MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, [ SOLAR AC DISCONNECT,POINT OF INTERCONNECTION RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY PHOTOVOLTAIC [PER CODE: NEC 690.17(E)] 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL ARRAYS ON ROOF �rriarl energy today' COMBINER/JUNCTION BOXES. (PER CODE: IFC605.11.1.4) (E) SUB PANEL (INTERIOR) • ., SOLAR DISCONNECT CONTRACTOR:SMART ENERGY TODAY,INC ELECTRIC SHOCK HAZARD LABEL LOCATION DO NOT TOUCH TERMINALS LICENSE AL CON CONTRACTOR: DISCONNECT, POINT OF INTERCONNECTION ELECTRICAL CONTRACTOR:C1151 TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION [PER CODE: NEC690.13(B)] CUSTOMER INFORMATION LABEL LOCATION A WARNING AC DISCONNECT,POINT OF INTERCONNECTION DUAL POWER SOURCE SECOND NAME:BRUCE ALLERT [PER CODE: NEC 690.17(E)] SOURCE IS PHOTOVOLTAIC SYSTEM WARNING-Electric Shock Hazard LABEL LOCATION No User Serviceable Parts inside ADDRESS:9210 SW OMARA ST, TIGARD, Contact authorized service provide POINT OF INTERCONNECTION OR 97223 for assistance [PER CODE: NEC705.12(D)(4)] / LABEL LOCATION CAUTION: SOLAR ELECTRIC (E) MAIN SERVICE PANEL (N) PV INVERTER (INTERIOR) 45°25'18.7"N 122°46'18.0"W INVERTER, JUNCTION BOXES(ROOF), (INTERIOR) AC DISCONNECT SYSTEM CONNECTED APN: 2S102DC00508 [PER CODE: NEC 690.13.G.3 &NEC 690.13.G.4] (E)UTI METER (N) AC DISCONNECT(INTERIOR) (EX LABEL LOCATION (EXTERIOR) AHJ:OR- CITY OF TIGARD WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, WARNING:PHOTOVOLTAIC UL969 AS STANDARD TO WEATHER RATING (UL LISTING ADDRESS : 9210 SW OMARA ST, TIGARD, OR 97223 UTILITY:PGE POWER SOURCE OF MARKINGS NOT REQUIRED), MIN 3/8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN PRN NUMBER:SET 007250 LABEL LOCATION THE MAIN SERVICE DISCONNECT,PLACED ON THE CONDUIT, COMBINER BOX OUTSIDE OF THE COVER WHEN DISCONNECT IS ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE [PER CODE: NEC690.31(G)(3)(4) & NEC OPERATED WITH THE SERVICE PANEL CLOSED. RED WITH WHITE LETTERING U.O.N. 690.13(G)(4)] (PWER CODE: NEC690.15 ,690.13(B)) PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. ILLUMINEFASTENERS APPROVED BY THE LOCAL JURISDICTION i INVERTER 1 SOLAR PV SYSTEM EQUIPPED I, Because quality matters WITH RAPID SHUTDOWN RATED MAXIMUM POWER- 'I1 42 A POINT CURRENT(Imp) TURN RAPID SHUTDOWN RATED MAXIMUM POWER- 380 V SWITCH TO THE WARNING PLACARDS POINT VOLTAGE(Vmp) "OFF"POSITION TO SOLAR WC TEE:. PV PANELS MAXIMUM SYSTEM SHUT DOWN PV SYSTEM VOLTAGE(Voc) 480 V AND REDUCE , DESIGNER/CHECKED BY: MAXIMUM CIRCUIT SHOCK HAZARD RK/BH 15 A CURRENT(Isc) IN THE ARRAY LABEL LOCATION LABEL LOCATION SCALE:AS NOTED REV:A AC DISCONNECT,DC DISCONNECT,POINT OF DC DISCONNECT[PER CODE: NEC690.14(C)(2)] INTERCONNECTION DATE:12/31/19 PL-� (PER CODE: NEC690.56(C)) SPEC SHEET www.axitecsolar.us www.axitecsolar.us -A-XI-1tC® -A-Xl-1 tC® 310 - 320 Wp high quality german solar brand high quality german solar brand AX l blackpremium HC 310-320 W AXIbl aCkpreml Um HC Electrical data(at standard conditions(STC)irradiance 1000 watt/m2,spectrum AM 1.5 at a cell temperature of 25°C) 120 cell monocrystalline Type Nominal output Nominal voltage Nominal current Short circuit current Open circuit voltage Module conversion High performance solar module Pmpp Umpp Impp Ise Uoc efficiency AC-310MH/1205 310 Wp 32.74 V 9.47 A 9.96 A 40.01 V 18.66% German engineered-made for America ` AC315MH/120S 315 Wp 32.97 V 9.56A 10.03A 40.13 V 18.96 ! AC-320MH/120S 320 Wp 33.21 V 9.64 A 10.11 A 40.25 V 19.26% ® 15 years manufacturer's warranty Five more years than industry standard Smart energy today' In Highest module performance through Design Limit values S 0 L A R ® Half-Cut-technology and tested materials $. Frontside 0.13 inch(3.2 mm)hardened,low-reflection white glass System voltage 1000 VDC(UL)1000 VDC(IEC) Cells 120 monocrystalline high efficiency cells Module Fire Performance TYPE 1(UL 1703) ''h t11 eil Positive power tolerance from 0-5 Wp Backside Composite film or CLASS C(IEC 61730) CONTRACTOR SMART ENERGY TODAY,INC 0 Higher guaranteed yield Frame 1.38 inch(35 mm)black aluminium frame LICENSE NO:CCB 198547 NOCT(nominal operating cell temperature)* 45°C+l-2K ELECTRICAL CONTRACTOR:C1151 ': Max.load-carrying capacity 113 PSF INSnow load of up to 113 psf Mechanical data Reverse current feed IR 20.OA CUSTOMER INFORMATION Stable module for a long life in extreme conditions L x W x H 65,94 x 39.06 x 1.38 inch(1675 x 992 x 35 mm) Permissible operating Weight 40.79 lbs(18.5 kg)with frame temperature -40°C to 85°C/-40F to 185F Gil100%electroluminescence inspection NAME:BRUCE ALLERT Ems Micro crack and hotspot free modules Power connection (No external voltages greater than Vo Socket Protection Class IP67 may be applied to the module) LIEAxitec-Soft-Grip-Seam aluminum frame Wire 43.3 inch,AWG 11 Plug-in system Plug/socket IP67,MC4 •NOCT,irradiance 800 W/m';AM 1.5; ADDRESS:9210 SW OMARA ST,TIGARD, Ezra Higher stability and easier handling wind speed 1 m/s;Temperature 20°C OR 97223 is High quality junction box and connector < 45°25'18.7"N 122°46'18.0"W system for a longer life time are Temperature coefficients APN: 2S102DC00508 _ -,, as Voltage Uoc -0.29%/K Exclusive linear AXITEC high performance guarantee! Current Isc 0.04%/K AHJ:OR CITY OF TIGARD Output Pmpp -0.39%/K •15 years manufacturers guarantee on 90%of the nominal performance I �`°n�a'°' A I haea UTILITY:PGE •25 years manufacturers guarantee on 85%of the nominal performance 25 Low-light performance(Example for AC-310M/120S) iL nx06wes°n9 I-U characteristic curve Current 1pp Voltage Upp PRN NUMBER:SET-007250 C O 200 WIm' 1.90A 32.15 V 400 W/m° 3.81 A 32.39 V • to v O AXITEC 800 W/m2 5.68 32.68 V ILLUMINE ����' 't00% 97% �/ EC Warranty Add s soo w/mY 7.57 A 3zs8 v a. so% iI�/////f/lvite”..._ ed Vatue! 100o w/m 9.47 A 32.7a v s 0,0 2 a5% 85% 1-8%more power Lid■ �S Because quality matters E eo ; ao% after 25 years ✓ Packaging la commercial LISTED Module pieces per pallet 30 a level warranty (PHOTOVOLTAIC MODULE OVER 600 VOLTS)5JK4 Module pieces per HC-container 780 MODULE SPEC SHEET m o% E487509 All dimensions in inch 3 1 _ 10 15 20 25 Years DESIGNER/CHECKED BY: Technical data are subject to change without prior notice,errors excepted. The measurement tolerances are+/-3% RK/BH SCALE:AS NOTED REV:A DATE:12/31/19 SS-1 SPEC SHEET / Single Phase Inverter With HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ Single Phase Inverter Z SE7600H-US SE11400H-US SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US � OUTPUT With HD-Wave Technology < Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 10000 „400 @ 240V VA 3300 @ 208V 3800 @ 240V 5000 @ 208V 10000 @ 208V 6000 @ 240V t1400 @ 240V for North America Maximum AC Power Output 3000 5000 7600 10 VA FAC Output Voltage Min.-Nom.-Max. I i 5000 @ 208V I 10000 @ 208v ♦ iVac SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / (2 240-264, 3300 @ 208V AC Output Voltage Min.-Nom:Max. ♦ Vac SE7600H-US / SE10000H-US / SE11400H-USmmi AC r Frequency "' AC Frequency(Nominal) 59.3-60-60.50 Hz 12-2 5 m Maximum Continuous Output 12.5 16 21 25 32 42 47.5 A Current YEAR Maximum Continuous Output 6 solar, a- -,,HD,L,, WARRANTY Current©208V 16 24 48.5 A V/ GFD!Threshold 1 A Utility Monitoring,!standing A solar,z,,: „HD..,., O i Protection,Country Configurable Yes Thresholds Smart ens today. INPUT ,. S LAR 5, Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power(0208V - 5100 - 7750 - - 15500 W ' ® ® ( - '.:: Transformer-less,Ungrounded Yes a'1 1 1 ' I Maximum Input Voltage 480 Vdc CONTRACTOR:SMART ENERGY TODAY,INC •••• LICENSE NO:CCB 198547 Nominal DC Input Voltage 380 400 Vdc ELECTRICAL CONTRACTOR:C1151 Maximum Input Current @240Vi 8.5 10.5 13.5 16.5 20 27 30.5 Adc O ® 1 Maximum Input Current ' 9 1313.527 Adc CUSTOMER INFORMATION .:♦ ::�, ::'" ..--. -:�. �k '�•. Max.Inpu[ShortCircuitC@went Current 45 Adc 0 q Reverse-Polarity Protection Yes p .-_.. 0 0 Ground-FaufIsolation Detection 600koSensitivity NAME:BRUCE ALLERT Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V % 98.5 @ 208V O 0 0 ® Nighttime Power Consumption <2.5 W IF 'III • • ADDITIONAL FEATURES ADDRESS:9210 SW OMARA ST, TIGARD, OR 97223 Supported Communication Interfaces RS485,Ethernet ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optionayn Rapid Shutdown-NEC 2014and 45°25'18.7"N 122°46'18.0"W Optimized installation with HD-Wave technology 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect APN: 25102DC00508 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 AHJ:O R- CITY OF TIGARD Specifically designed to work with I Extremely small Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) power optimizers Emissions FCC Part 15 Class B UTILITY:PGE I Record-breaking efficiency .1 Built-in module-level monitoring INSTALLATION SPECIFICATIONS AC output Conduit Size/AWG 3/4°minimum/14-6 AWG 3/4`minimum/14-4 AWG PRN NUMBER:SET-007250 Range I Fixed voltage inverter for longer strings I Outdoor and indoor installation DC Input Conduit Size/#of Strings/ 3/4"minimum/1-2strings/14-6AWG 3/4'minimum/1-3 strings/14-6 AWG AWG Range Dimensions with Safety Switch in/ d Integrated arc fault protection and rapid shutdown for Optional:Revenue grade data,ANSI C12.20 (HxWxD) 177x14.6x6.8/450x370z,74 21.3 x14.6 x 7.3/540 x 370 x185 mm � ILLUMINE i NEC 2014 and 2017,per article 690.11 and 690.12 Class 0.5(0.5%accuracy) Weight with Safety Switch 22/10 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA ► Because quality matters i UL1741 SA certified,for CPUC Rule 21 grid cooling Natural Convection compliance Operating Temperature Range -40 to+140/-25 to+600'(-40°F/-40°C option)G' °F/°C Protection Rating NEMA 4X(Inverter with Safety Switch) INVERTER SPEC SHEET „ n .For other regents settings please contact Sdarter v support s o I a r ' R1 A higher current source may be used;the inverter will limit its Inputcurrent to the values Rated vs. n "° 'a Revenue grade inverter P/N:SbooaH-USOOONNC2 solaredge.eom .For power de-rating information refer to httpsy/wwwsolaredge.com/sites/default/files/se-temperature-derating-note-na.pdf et ` e'-40 version P/N SEbno,H-USOOONNU4 DESIGNER/CHECKED BY: e SolarEdge Technologies,Inc.AS rights reserved sOWtEDGE,the SdarEdge bgo,OPTIMIZED BY sOLAREDGE are trademarks or registered trademarks of solarEdge Technologies,Inc.All Ro H S other trademarks mentioned hares are trademarks of Mee respective owners.Data:12ROt8/V01/ENG NAM.subject to change without notice. RK/BH SCALE:AS NOTED REV:A DATE:12/31/19 SS-2 SPEC SHEET Power Optimizer ; i. i..s. O.r. ra : 48 _ . - -10 For North America Power Optimizer O P320 / P340 / P370 / P400/ P405 / P505 P340 P370 P400 P505 For North America Optimizer model P320 (for higher- P405 (for high- (for 72&96- (for higher (typical module (for 60-cell power (for thin film P320/ P340 / P370 / P400 / P405 / P505 compatibility modules) Power 60-cell 60 and 72-cell cell modules) current modules) modules) modules) modules) m INPUT Rated Input DC Powedtl 320 I 340 370 400 405 505 W Absolute Maximum Input 2 Voltage 48 60 80 125w 8310 Vdc (Voc at lowest temperature) ( YEAR0 MPPT Operating Range 8-48 8-60 8-80 12.5-105 12.5-83 Vdc 1 WARRANTY MMaxrrnum Short Circuit Current 11 10.1 14 Adc Maximum DC Input Current 13.75 12.63 17.5 Adc _.,...,_,_,„. ..... -- - Maximum Efficiency 99.5 % 1111.1.1.1 Weighted Efficiency 98.8 98.6 % Overvoltage Category D E01.1101 OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output CurrentM 15 Adc energy may OUTPUTU Output DURING Voltage 60 I 85 Vdc SOLAR G STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE . INVERTER OFF) Safety Output Voltage per IPower Optimizer 1±0.1 Vdc t ri STANDARD COMPLIANCE CONTRACTOR:SMART ENERGY TODAY,INC EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 LICENSE NO:CCS 198547 ELECTRICAL CONTRACTOR:C1151 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS CUSTOMER INFORMATION Maximum Allowed System 1000 Vdc Voltage NAME:BRUCE ALLERT Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(W x L x H) 128 x152 x28/5 x 5.97 x 1.1 128x152x36/ 128x152x50/ 128x152x59! mm/in 5x5.97x1.42 5x5.97x1.96 5x5.97x2.32 Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/lb Input Connector MC40 ADDRESS:9210 SW OMARA ST, TIGARD, Output Wire Type/Connector Double Insulated;MC4 OR 97223 Output Wire Length 0.95/3.0 I 1.2/3.9 m/ft Input Wire Length 0.16/0.52 m/ft Operating Temperature Range -40-+85/-40-+185 'C/F 45°25'18.7"N 122°46'18.0"W PV power optimization at the module-level Protection Rating IP68/NEMA6P APN: 2S102DC00508 Relative Humidity 0-100 % m Rated SIC power of the module.Module of up to+516 power tolerance allowed AIJ:OR- CITY OF TIGARD m NEC 2017 requires max Input voltage be not more than 80V 7 Specifically designed to work with SolarEdge ' Fast installation with a single bolt wFor other connector types please contact SolarEdge inverters UTILITY:PGE I Next generation maintenance with module- PV System Design Using Single Phase Single phase Three Phase 208V Three Phase 480V I Up to 25%more energy level monitoring a SolarEdge Inverter'''' HD-Wave Minimum Stung Length P3 P340,P370, 8 to 18 PRN NUMBER:SET-007250 I Superior efficiency(99.5%) if Meets NEC requirements for arc fault (Power Optimizers) P405/P505 6 8 14 protection(AFCI)and Photovoltaic Rapid Maximum String Length 25 25 50.' ;; I Mitigates all types of module mismatch losses, (Power Optimizers) ILLUMINE i 9 YP Shutdown System(PVRSS) s7oo(6000witn from manufacturing tolerance to partial Maximum Power per String SE7600-US-5E11400- 5250 6000o 12750m W ,E shading I Module-level voltage shutdown for installer us) f. Parallel Strings of Different Lengths Yes Because quality matte's and firefighter safety or Orientations if Flexible system design for maximum space For detailed string sizing information refer to:http7/semsolaredge.com/sites/defaulVfiles/string-sizingna.pdf N It is not allowed to mix P405/P505 with P320/P340/P370/P400/P600/P700/P800 in one string utilization w A string with more than 30 optimizers does not meet NEC rapid shutdown requirements,safety voltage will be above the 30V requirement m For 5E14.4KUS/SE43.2KUS:R is allowed to install up to 6,500W per string when 3 strings are connected to the inverter(3 strings per unit for SE43.2KU5)and when OPTIMIZER SPEC SHEET the maximum power difference between the strings is up to 1,000W m For SE30KU5/SE33.3KUS/SE66.61W5/SEIODKUS:it is allowed to install up to 15,000W per string when 3 strings are connected to the inverter(3 strings per unit for SE66.6KUS/SE100KUS) and when the maximum power difference between the strings is up to 2A000W solar DESIGNER/CHECKED BY: solaredge.com r C SolarEdge Technologies ad.MI rights reserved.SOIAREDGr the SolarEdge logo,OPtIMRED BY 501AREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc. C E Ro H S RK/B H All other trademarks mentioned herein are trademarks of their respective owns.Dote:12/2018/V01/ENG NAM.Subject to charge without nonce. SCALE:AS NOTED REV:A DATE:12/31/19 SS-3 SPEC SHEET I,Allilk IRONRIDGE FlashFoot2 Installation Features The Strongest Attachment in Solar ,,. - 0 Ai Alignment Markers IronRidge FlashFoot2 raises the bar in solar roof ; protection.The unique water seal design is both „ - Quickly align the flashing with chalk lines to find pilot holes. elevated and encapsulated,delivering redundant layers of protection against water intrusion. In addition,the , - twist-on Cap perfectly aligns the rail attachment with the lag bolt to maximize mechanical strength. "` »�,, =" : 0 B Rounded Corners F ._ x r, .-. ...� Makes it easier to handle and insert under the roof shingles. I '. C 4 Reinforcement Ribs rart energy today° 0 SOLAR Twist-On Cap 'i Help to stiffen the flashing and prevent any bending or FlashFoot2's unique Cap design encapsulates r crinkling during installation. the lag bolt and locks into place with a simple Three-Tier Water Seal ,rr:Ir,,, twist.The Cap helps FlashFoot2 deliver FlashFoot2's seal architecture utilizes three r CONTRACTOR:SMART ENERGY TODAY,INC superior structural strength,by aligning layers of protection.An elevated platform LICENSE NO:CCB 198547 the rail and lag bolt in a concentric diverts water away,while a stack of rugged ELECTRICAL CONTRACTOR:C1151 load path. *� components raises the seal an entire inch. The seal is then fully-encapuslated by the , Cap.FlashFoot2 is the first solar attachment CUSTOMER INFORMATION to pass the TAS-100 Wind-Driven Rain Test. 4 k 1200 NAME:BRUCE ALLERT Benefits of Concentric Loading ,. N 1000°'FwhFoo42 Traditional solar attachments have a .n ,,,. 3 c^.+x' �, 800 »FNahFoot '- - .. horizontal offset between the rail and lag r0 -Leaping competitor bolt,which introduces leverage on the lag a 600 ADDRESS:9210 SW OMARA ST, TIGARD, ,Mary.. bolt and decreases uplift capacity. aoo OR 97223 ' _•Low-Coat Competitor FlashFoot2 is the only product to align the D 200 45°25'18.7"N 122°46.18.0"W "" rail and lag bolt.This concentric loading APN: 2S102DC00508 design results in a stronger attachment for o 1 2 3 the system. Rail-to-Lag Offset(in) AH1:OR- CITY OF TIGARD t UTILITY:PGE ' Testing &Certification PRN NUMBER:SET-007250 Structural Certification- :� W` Designed and Certified for Compliance with the International Building Code&ASCE/SEI-7. 4(.9 ILLUMINE i; r Single Socket Size z �' . Because quality matters '^ 37' Water Seal Ratings A custom-design lag bolt allows . ` ." you to install FlashFoot2 with a,'' Water Sealing Tested to UL 441 Section 27"Rain Test"and TAS 100-95"Wind Driven Rain Test"by Intertek. the same 7/16"socket size used on other Flush Mount Ratings applicable for composition shingle roofs having slopes between 2:12 and 12:12. MOUNT SPEC SHEET System components. Water-Shedding Design UL 2703 An elevated platform diverts water DESIGNER/CHECKED BY: a_ away from the water seal. Conforms to UL 2703 Mechanical and Bonding Requirements.See Flush Mount Install Manual for full ratings. RK/BH a Atr ..+. 'Y . .s4 ;. xg. R.,=4 ;'" G 59 a� r .a _ 1:w , w.: „� e w....... - Y i...S ...v ,.., � . _ , it, c z��w.3x... ....x..�' s 4. N .__S ri. SCALE:AS NOTED REV:A DATE:12/31/19 SS-4 SPEC SHEET .A�,;. IRONRIDGE XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads,while minimizing material costs. Depending on your location,there is an XR Rail to match. Solar Is No Always Sung Over their lifetime,solar panels experience countless >' - extreme weather events. Not just the worst storms in years, . x ' .„.- f �,:,- iiii but the worst storms in 40 years. High winds capable of ,. „,'` . 4 i - ` i ripping panels from a roof, and snowfalls weighing t' T t enough to buckle a panel frame. ,- 7l r ' / */ : .7'' 7' 1 -,L* - -f.,1: , -......._.....................4sli -- 41-- XR Rails are the structural backbone preventing ? 1, these results.They resist uplift, protect f �! , XR10 XR100 XR1000 against buckling and safely and efficiently ,: r' .,, ' } 4 XR10 is a sleek,low-profile mounting XR100 is the ultimate residential XR1000 is a heavyweight among transfer loads into the building structure. - . x /j . 1 rail,designed for regions with light or mounting rail.It supports a range of solar mounting rails It's built to handle Their superior spanning capability -.' * no snow.It achieves 6 foot spans,while wind and snow conditions,while also extreme climates and spans 12 feet or y remaining light and economical. maximizing spans up to 8 feet. more for commercial applications. requires fewer roof attachments, t • reducing the number of roof {` f • 6'spanningcapability • 8'spanningcapability • 12'spanningcapability rati energy today' penetrations and the amount * • • Moderate load capability •• Heavy load capability •• Extreme load capability SOLAR • Clear anodized finish • Clear&black anodized finish • Clear anodized finish of installation time. -.. iii, e • Internal splices available • Internal splices available Internal splices available ,ii. Rail Selection CONTRACTOR:SMART ENERGYTODAY,INC LICENSE NO:CCB 198547 g� r-. ELECTRICAL CONTRACTOR:C1151 The following table was prepared in compliance with applicable engineering codes and standards. Values are ; based on the following criteria:ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean CUSTOMER INFORMATION Building Height of 30 ft.Visit IronRidge.com for detailed span tables and certifications. NAME:BRUCE ALLERT Load Rail Span ,. Snow(PSF) Wind(MPH) ' 5'4111311111„ 8 10' v Force Stabilizing Curve ' 100 ADDRESS:9210 SW OMARA ST, TIGARD, s .. '. Sloped roofs generate both vertical and lateral 120E- OR 97223 -�.Y-*` forces on mounting rails which can cause them None I � to bend and twist The curved shape of XR Rails f t is specially designed to increase strength in both 140 XR10 XR100 XR1000 0 0 P Y 9 9 45 25'18.7"N 122 46'18.0"W directions while resisting the twisting.This unique -.,, .. " ;a,,- feature ensures greater security during extreme 160 °. APN: 2S102DC00508 weather and a longer system lifetime. s°aa 100 ;r� , AHJ:OR CITY OF TIGARD a 120 10-20 — �., UTILITY:PGE kG )/ \ 140 3x ,.,,t „ 160 r PRN NUMBER:SET-007250 100 30 x _....�._ 160 ILLUMINE i Compatible with Flat&Pitched Roofs Corrosion-Resistant Materials 100 • ♦s. XR Rails are IronRidge offers All XR Rails are made of marine-grade w. 40 Because quality matters 0 compatible with N.7,,,, a range of tilt leg aluminum alloy,then protected with an 160 i , FlashFoot and t�7 options for flat anodized finish.Anodizing prevents surface ' - other pitched roof i t I roof mounting and structural corrosion,while also providing 50-70 160 Xk-"ra fl.x E RAIL T7 attachments. applications. 4 a more attractive appearance. '°"°" - RAIL SPEC SHEET k 80-90 160 r�,�� .- DESIGNER/CHECKED BY: 4. dlC. .'',g„ 2m.Tsp-.,-, www.r¢a- , r a '' -::'. R / H SCALE:AS NOTED REV:A DATE:12/31/19 SS-5 SPEC SHEET 128357 Industrial Blvd. (28357 Industrial Blvd. IRONRIDGE !Hayward,CA 94545 � IRONRIDGE Hayward,CA 94545 1-800-227-9523 1-800-227-9523 IronRidge.com IronRidge.com Attn:Corey Geiger,COO,IronRidge Inc. �ofESSi Date:September 5th,2019 Sincerely, � a 'K Date: Re:Structural Certification for the IronRidge FlashFoot2 W0 l604 - 201 9.09.05 This letter addresses the structural capacity of the IronRidge FlashFoot2(FF2)component for use as a roof attachment for PV solar tF * 10:51:36 systems. FF2 is composed of an aluminum Cap,a 9"x 12"aluminum flashing,and an aluminum stabilizing base.The flashing *,� component is attached to an underlying roof rafter using a 5/16"lag bolt. The assembly details are shown in Exhibit EX-0013. .• ''' —07'00' Gang Xuan,SE w• ; OFC The referenced uplift and lateral resistance of FF2 is based on structural tests conforming to ASTM D1761-12"Standard Test Methods Senior Structural Engineer for Mechanical Fasteners in Wood." Testing was performed by installing a FF2 component on a sample roof deck composed of composition shingles covering''/"OSB Board over a 2x4 Douglas Fir rafter as shown in Figure 1. The moisture content and specific gravity of the rafter was measured and recorded per ASTM D2395-14"Standard Test Methods for Density and Specific Gravity (Relative Gravity)of Wood and Wood-Based Materials." The moisture content for uplift test samples was between 8%and 15%with an average specific gravity of 0.54. The moisture content for lateral test samples was 13%with an average specific gravity of 0.54. The critical failure mode observed for both the uplift and lateral tests was pullout of the 5/16"lag screw from the rafter. The average Srrirt energy today • peak loads recorded at the critical failure point for the uplift and lateral tests were 3203 lbs.and 1237 lbs.,respectively. A safety factor of 3.0 was applied to certify the allowable uplift capacity to 1067 lbs.and the allowable lateral capacity to 412 lbs.for a SOLAR substrate with a specific gravity of 0.54. 3 , For rafter wood species with specific gravity other than 0.54,the allowable uplift capacity shall be adjusted by a factor of(°) per CONTRACTOR:SMART ENERGY TODAY,INC ``0.54/ 98547 AP&PA National Design Specification Eq. 12.2-1 ,and the allowable lateral capacities shall be per the equation 1— 0.5—G) LICENSE AL CON CONTRACTOR: 9 P ( ) P adjustedcl ( ELECTRICAL CONTRACTOR:C1151 from APA Engineering Wood Construction Guide APA 2011(G is wood specific gravity). For the common wood species,the allowable capacities are provided in Table 1. CUSTOMER INFORMATION Table 1. IronRidge FlashFoot2 Allowable Capacities n) NAME:BRUCE ALLERT NDS Assigned Specific Allowable Uplift Capacity Allowable Lateral Capacity Wood Species Gravityl2) (Ibs)(3) (Ibs))3) Douglas Fir,Larch 0.50 951 396 Douglas Fir,South 0.46 839 380 ADDRESS:9210 SW OMARA ST, TIGARD, Hem,Fir 0.43 758 368 OR 97223 Hem,Fir(North) 0.46 839 380 Southern Pine 0.55 1097 416 Spruce,Pine,Fir 0.42 732 364 45°25'18.7"N 122°46'18.0"W APN: 2S102DC00508 (1)The minimum size rafter is 2x4. (2)The listed specific gravities are per 2015 NOS Table 12.3.3A. AHJ:O R CITY O F TIGARD (3)Values are based on securing lag bolt within center 1/3 of rafter width with a minimum 2.5"end distance,and loading directions as shown in Figure 1. UTILITY:PGE Lateral Uplift PRN NUMBER:SET-007250 e ILLUMINE i Because quality matters Figure 1 CERTIFICATE ©2019 IronRidge,Inc. FlashFoot2 Certification Letter-1 ©2019 IronRidge,Inc. FlushFoot2 Certification Letter-2 DESIGNER/CHECKED BY: RK/BH SCALE:AS NOTED REV:A DATE:12/31/19 SS-6 SPEC SHEET I 1495 Zephyr Avenue 1495 Zephyr Avenue IRONRIDGE 'Hayward,CA 94544 /jr IRONRIDGE Hayward,CA 94544 1-800-227-9523 I 1-800-227-9523 I IronRidge.com IronRidge.com Attn:Corey Geiger,COO,IronRidge Inc. Date:September 7<h,2018 The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments,PV modules,or the underlying roof supporting Re:Structural Certification and Span Tables for IronRidge Flush Mount System members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush Pip Mount System is a proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or �SSr` NaINr landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum Sincerely, 4�� �?.t Date: 91200PE � XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof 0 o•On• o O attachment with 3/8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchionC O 7 that is fastened to the underlying roof structure. Assemblydetails of a OREGON y g typical Flush Mount installation and its core 2 components are shown in Exhibit EX-0015. 'q,�a2X�pta 0 �0 0 •27 _07'001 The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards EXPIRES: 1)0/1012otp listed below,for the load conditions and configurations tabulated in the attached span tables. Gang Xuan,PE,LEED AP Siftedlnlrgy today' • ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures(ASCE 7-10) Senior Structural Engineer SQL A R • 2015 International Building Code(IBC-2015) • 2015 Aluminum Design Manual(ADM-2015) '1,17 CONTRACTOR:SMART ENERGY TODAY,INC The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the LICENSE NO:CCB CONTRACTOR: R:C1151 respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones 1,2&3,and roof slopes from 0°to 45°. The span tables are applicable provided that the following conditions are met: CUSTOMER INFORMATION 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment NAME:BRUCE ALLERT fastener) 2. The underlying roof pitch,measured between roof surface and horizontal plane,is 45°or less. ADDRESS:9210 SW OMARA ST, TIGARD, 3. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from OR 97223 grade,does not exceed 30 feet. 45°25'18.7"N 122°46'18.0"W 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module APN: 2S102DC00508 width shall not exceed 48". AH):OR-CITY OF TIGARD 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. UTILITY:PGE PRN NUMBER:SET-007250 •(J ILLUMINE i Because quality matters CERTIFICATE ©2018 IronRidge,Inc. OR Flush Mount System Certification Letter-1 ©2018 IronRidge,Inc. OR Flush Mount System Certification Letter-4 DESIGNER/CHECKED BY: RK/BH SCALE:AS NOTED REV:A DATE:12/31/19 SS-7