Loading...
Report /61320/9-4924/6. i4'/OO 5W7z4A 11/12/19 RECEIVP Curtiss-Wright Corporation DEC 9 2015 14100 SW 72nd Ave, CITY OF CARD Portland,OR,97224-8078 BUILDING DIVISION an OREGON�j to, A7y 13, 7Fa O FIRE ALARM SUBMITTAL BOOK s, 3 oZo ROBERT YOUNG JOHNSON CONTROLS PLEASE PROVIDE GIBBENS DRAKE SCOTT,INC • COMP!:L=TED NFPA 72 9201 E.63rd STREET,SUITE 100 RECORD OF RAYTOWN,MISSOURI 64133 COMPLETION AT Johnson FINAL INSPECTION Controls ENGINEERING Johnson � Controls 1 Product Information Table of Contents Item # Fire Alarm Control Panel 1 ES-50X ASSY, FNL,ADDRESSABLE,50 POINT, FL 2 FCPS-24FS8-A8 24 VOLT,8 AMP REMOTE POWER SUPPLY 4 CLASS B OR A(WITH ZNAC-4 MODULE) 3 TG-7FS AT&T(LTE/3G/4G)CELL ALARM COMMUNICATOR UL COMMERCIAL FIRE 4 ANN-80-A8 LCD ANNUNCIATOR,80 CHARACTER W/ACK, SIL, RES,DRIL BUTTONS 5 06-SSU00672 FIRE DRAWING BOX RED Initiating Devices 1 BG-12LX ADDRESSABLE PULL STATION 2 SD365 ADDRESSABLE LOW-PROFILE PHOTOELECTRIC SMOKE DETECTOR 3 B300-6 WHITE,6"BASE, STANDARD FLANGED LOW-PROFILE MOUNTING BASE 4 D355PL PHOTOELECTRIC LOW-FLOW DUCT SMOKE DETECTOR. 5 RTS151 KEY REMOTE TEST STATION W/KEY TO TEST DUCT SMOKE DETECTORS FROM A CONVENIENT LOCATION Supervising Module & Relay 1 MMF-300 MONITOR MODULE SINGLE INPUT 2 CRF-300 ADDRESSABLE RELAY MODULE DPDT Notification Appliances 1 SRL STROBE, RED,WALL MOUNT,4X4 2 P2RK RED,OUTDOOR HORN STROBE WITH SELECTABLE SETTINGS, BACK BOX INCLUDED 3 P2RL 2-WIRE WALL HORN STROBE, RED,4X4 4 PC2RL 2-WIRE CEILING HORN STROBE, RED ` DF-60953:C ES-50X Intelligent Addressable FACP a Flre•treAtarms with Communicator by Honeywell Addressable Fire Alarm Control Panels General The ES-50X is the latest intelligent addressable fire alarm control _ panel (FACP) from Fire•Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES-50X comes with a pre-installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES-50X programs just like Fire•Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) ...... communicator.The POTS transmits system status(alarms,troubles, AC loss, etc.)to a Central Station via the public switched telephone ,... —.,.' network.The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL-MOD or CELL-CAB-FL. Remote and local programming of the control panel is possible using the FS-Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port(and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk-test data, current status and system volt- • Maintenance alert warns when smoke detector dust accumula- ages by means of a USB flash drive. tion is excessive The power supply and all electronics are contained on a circuit • One-person audible or silent walktest with walktest log&printout board supported on a new quick install chassis and housed in a • System alarm verification selection per detector point _ metal cabinet. Available accessories include local and remote • PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA upload/download software, remote annunciators, and reverse polar- 72 compliant) ity/city box transmitter(4XTMF). • Up to 16 ANN-BUS annunciators-8 per each ANN-Bus Features • Remote Acknowledge, Alarm Silence, Reset and Drill via • addressable modules or remote annunciator • Listed to UL Standard 864, 10th edition • Upload/Download of program and data via USB with optional FS- • Pre-installed IPOTS-COM Ethernet IP and POTS(Plain Old Tele- Tools Programming Utility phone Service)Central Station Communicator • Optional CELL-MOD or CELL-CAB-FL GSM Central Station SLC COMMUNICATION LOOP Communicator over AlarmNet® • Supports LiteSpeedTM and CLIP protocols • Compatible with SWIFT®wireless devices • SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with • Auto-programming (learn mode) reduces installation time. twisted, unshielded wire Reports two devices set to the same address • Single addressable SLC loop which meets NFPA Class B and • Two independently programmable, built-in Style Z (Class A) or Class A requirements Style Y(Class B)NAC circuits • 50 addressable device capacity(any combination of addressable • Selectable strobe synchronization for System Sensor,Wheelock, detectors and modules) and Gentex devices • Compatible with Fire•Lite's addressable devices (refer to the • Notification Appliance Circuit End of Line resistor matching SLC Wiring Manual) • Four programmable function keys for ease of maintenance NOTIFICATION APPLIANCE CIRCUITS(NACS) • Two programmable relays and one fixed trouble relay • Two independently programmable output circuits. Circuits can be • Built-in Programmer configured for the following outputs: • Integral 80-character LCD display with backlighting –Style Y(Class B) • Real-time clock/calendar with automatic daylight savings control –Style Z(Class A) • History file with 1,000 event capacity • Silence Inhibit and Autosilence timer options • Addressable sounder base • Continuous, March Time, Temporal, or California code for main • Multi-criteria detector (smoke, heat, CO) with programmable circuit board NACs with two-stage capability response • Selectable strobe synchronization per NAC • Control module delay timer • 2.5 A special application,250mA regulated, total power for NACs • Automatic detector sensitivity testing(NFPA 72 compliant) NOTE:Maximum or total 24VDC system power shared between all NAC • Automatic device type-code verification circuits and the ANN-BUS is 2.7 A • Point trouble identification PROGRAMMING AND SOFTWARE • Waterflow selection per module point • Alarm verification selection per detector point • Autoprogramming (learn mode)reduces installation time DF-60953:C•7/16/2018—Page 1 of 4 • Custom English labels (per point) may be manually entered or OPTIONAL MODULES selected from an internal library file 4XTMF Reverse Polarity Transmitter Module: Provides a super- • Two programmable Form-C relay outputs vised output for local energy municipal box transmitter, alarm and • 50 software zones trouble. Includes a disable switch and disable trouble LED. • Continuous fire protection during online programming • Program Check automatically catches common errors not linked COMPATIBLE ANNUNCIATORS to any zone or input point ANN-80: Remote, red LCD annunciator mimics the information dis- • OFFLINE PROGRAMMING: Create the entire program in your played on the FACP LCD display. Recommended wire type is un- office using FS-Tools,a Windows®-based software package, and shielded. upload/download system programming locally. Offline program- ANN-100: Remote LCD annunciator mimics the information dis- ming requires an ethernet connection. FS-Tools is available on played on the FACP LCD display. Recommended wire type is un- www.firelite.com. shielded. For use in FM applications only. User interface ANN-I/O: LED Driver Module provides connections to a user sup- LED INDICATORS plied graphic annunciator. (See DF-52430.) ANN-LED:Annunciator Module provides three LEDs for each zone: • Fire Alarm(red) Alarm,Trouble,and Supervisory.Ships with red enclosure. (See DF- • CO Alarm(red) 60241.) • AC Power(green) ANN-RLED: Provides alarm(red)indicators for up to 30 input zones • Supervisory(yellow) or addressable points. (See DF-60241.) • Trouble(yellow) ANN-RLY:Relay Module provides 10 programmable Form-C relays. • Ground fault(yellow) Can be mounted inside the cabinet. (See DF-52431.) • Battery fault(yellow) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF-52429.) • Disabled(yellow) ADDRESSABLE DEVICES • Maintenance(yellow) • Communication(yellow) All feature a polling LED and rotary switches for addressing. • Alarm Silenced(yellow) SD365:Addressable low-profile photoelectric smoke detector. Lite- Speed only. • F1-F4 Programmable Function Keys(yellow) SD365-IV: Addressable low-profile photoelectric smoke detector. KEYPAD Ivory. LiteSpeed and CLIP mode. • 16 key alpha-numeric pad SD365T:Addressable low-profile photoelectric smoke detector with • Acknowledge thermal sensor. LiteSpeed only. • Alarm Silence SD365T-IV: Addressable low-profile photoelectric smoke detector • Drill(Manual Evacuate) with thermal sensor. Ivory. LiteSpeed and CLIP mode. • Four(4)programmable function keys SD365R: Remote test capable addressable photoelectric smoke - etector for use with DNR(W)duct detector housing. LiteSpeed only. • Reset(lamp test) , SD365R-IV: Remote test capable addressable photoelectric smoke Product Line Information etector for use with DNR(W) duct detector housing. Ivory. Lite- Speed and CLIP mode. ES-50X:Addressable Fire Alarm Control Panel with one SLC loop. H365: Low profile 135°F fixed thermal sensor. LiteSpeed only. Includes main circuit board with display, pre-installed IPOTS-COM communicator, chassis with transformer, backbox with door, plastic H365-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed bag containing screws, cables, key, etc. (For ES-50XC, refer to DF- and CLIP mode. 60954.) H365R: Low-profile, intelligent, rate-of-rise thermal sensor. Lite- FS-Tools: Programming software for Windows®-based PC com- Speed only. puter.Available for download at www.firelite.com. H365R-IV: Low-profile, intelligent, rate-of-rise thermal sensor. Ivory. CELL-CAB-FUCELL-MOD:Optional GSM communicators. LiteSpeed and CLIP mode. IPOTS-COM: Dual technology (POTS and IP) communicator. H365HT: Low-profile intelligent 190°F/88°C fixed thermal sensor. (replacement board) LiteSpeed only. DP-ES-R:Optional dress panel for the ES-50X. H365HT-IV: Low-profile intelligent 190°F/88°C fixed thermal sensor. TR-CE:Optional trim ring for semi-flush mounting. Ivory. LiteSpeed and CLIP mode. BB-2F: Optional cabinet for one or two modules. Legacy Devices BB-6F: Optional cabinet for up to six modules mounted on CHS-6 SD355:Addressable low-profile photoelectric smoke detector. chassis. BB-26: Battery backbox, holds up to two 25 AH batteries&CHG-75. SD355T:Addressable low profile photoelectric smoke detector with thermal sensor. BB-55F: Battery box, houses two 55 AH batteries SD355R: Remote test capable addressable photoelectric smoke CHS-6:Chassis,mounts up to six multi-modules in a BB-6F cabinet. detector for use with DNR(W)duct detector housing. C5 H75: Battery charger for lead-acid batteries with a rating of 25 to SD355CO:Addressable, low-profile device that provides fire, heat, 7CHG-120F: Remote battery charging system for lead-acid batteries and carbon monoxide(CO)detection. with a rating of 55 to 120 AH. Requires additional BB-55F for mount- H355: Fast-response, low-profile heat detector. ing. H355R: Fast-response, low-profile heat detector with rate-of-rise BAT Series: Batteries,see data sheet DF-52397. option. PRN Series: UL listed compatible event printer. Uses tractor-fed H355HT: Fast-response, low-profile heat detector that activates at paper. 190°F/88°C. Page 2 of 4—DF-60953:C•7/16/2018 AD355: Low-profile, intelligent, "Adapt" multi-sensor detector W-BG12LX: LiteSpeed Intelligent wireless pull station. (B350LP base included). WAV-RL,WAV-WL,WAV-CRL,WAV-CWL:LiteSpeed Intelligent AV B200S: Programmable, addressable sounder base bases. B200SR:Addressable sounder base. W-USB: Wireless USB radio/antenna dongle that plugs into the BEAM355: Intelligent beam smoke detector. USB port of a PC running SWIFT Tools. BEAM355S: Intelligent beam smoke detector with integral sensitiv- SWIFT Tools: Programming and diagnostic utility for the Wireless ity test. Gateway and devices.Available for download from firelite.com. D355PL: InnovairFlex low-flow non-relay duct detector housing; NOTE: For more information on Compatible Addressable Devices for SD355R. use with the ES-50X, see the following data sheets (document num- includesbers): SD365 Series (DF-61010), H365 Series (DF-61011), AD355 DNR: InnovairFlex low-flow non-relay duct-detector housing. (Order (DF-52386), BG-12LX(DF-52013), CMF-300-6 (DF-52365), CRF-300-6 SD355R/SD365R separately.) (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 DNRW: InnovairFlex low-flow non-relay duct detector housing, with Series (DF-52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 NEMA-4 rating.Watertight.(Order SD355R/SD365R separately.) Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD355/SD355T (DF-52384), and SLC Wiring Manual Addressable Modules (51309). MMF-300: Addressable Monitor Module for one zone of normally- NOTE:Legacy 300 Series detection devices such as the CP300/CP350, open dry-contact initiating devices. Mounts in standard 4.0" (10.16 SD300(T)/SD350(T)and older modules such as the M300, M301, M302, cm.) box. Includes plastic cover plate and end-of-line resistor. Mod- C304, and BG-10LX are not compatible with LiteSpeed polling. If the ule may be configured for either a Style B(Class B)or Style D(Class SLC contains one of these devices, polling must be set for standard A)IDC. CLIP protocol. Please consult factory for further information on previous MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- 300 Series devices. vides two Style B(Class B)only IDCs. ADDRESSABLE DEVICE ACCESSORIES MMF-301: Miniature version of MMF-300. Excludes LED and Style End-of-Line Resistor Assembly (R-47K and R-3.9K): The D option. Connects with wire pigtails. May mount in device backbox. 47k ohm assembly supervises the MMF-300, MDF-300, MMF-301, MMF-302:Similar to MMF-300.Addressable Monitor Module for one and CMF-300 module circuits. The 3.9k ohm assembly supervises zone of conventional two-wire detectors. Requires resettable 24 the MMF-302 module circuit. These resistors are included with each VDC power. Refer to the Device Compatibility Document for listed module. compatible devices and quantity limitation. Power Supervision Relay: Supervises the power to 4-wire smoke CMF-300: Addressable Control Module for one Style Y/Z (Class B/ detectors and notification appliances. A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires Wiring Requirements external 24 VDC to power notification appliances. CRF-300:Addressable relay module containing two isolated sets of While shielded wire is not required, it is recommended that all SLC wiring betwisted-pairrthe panel minimize details. the effects of electrical interfer- Form-C contacts, which operate as a DPDT switch. Mounts directly ence. Refer to a 4.0"(10.16 cm.)box,surface mount using the SMB500. tomanual for wiring BG-12LX: Addressable manual pull station with interface module mounted inside. 1300:This module isolates the SLC loop from short circuit conditions - (required for Style 6 or 7 operation). ISO-6: Six-fault isolator module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SMB500: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CRF-300-6: Six-relay control module(Form-C relays). Mount one or two modules in a BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. SWIFT Wireless Devices W-GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent,wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T: intelligent wireless photo/heat detector. W-H355: LiteSpeed intelligent wireless fixed-temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W-CRF: LiteSpeed Intelligent wireless relay module. DF-60953:C.7/16/2018—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0—49°C/32 • Intelligent Signaling Line Circuits 1 —120°F and at a relative humidity 93%±2%RH(noncondensing)at • Addressable device capacity 50 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's • Programmable software zones 50 standby batteries and the electronic components may be adversely • • Annunciators 16 affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15—27°C/60— Electrical Specifications 80°F. AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto-sensing- no switch required. Wire size: minimum 14 AWG NFPA Standards (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. The ES-50X complies with the following NFPA 72 Fire Alarm Sys- Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger tems requirements: Capacity: 7-18 AH (ES-50X cabinet holds maximum of two 18 AH —LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- batteries.) sory). Communication Loop: Supervised and power-limited. —AUXILIARY (Automatic, Manual and Waterflow) (requires Notification Appliance Circuits: Terminal Block provides connec- 4XTMF). tions for two NACs, Style Y(Class B) or Style Z (Class A). Special —REMOTE STATION (Automatic, Manual and Waterflow) Application power. Power-limited, supervised circuitry. Maximum (Where a DACT is not accepted,the alarm,trouble and supervi- signaling current per circuit: 2.5 amps special application, 250mA sory relays may be connected to UL 864 listed transmitters. For regulated. End-of-Line Resistor: 4.7k ohm, 1/2 watt (P/N 71252 UL reverse polarity signaling of alarm and trouble, 4XTMF is listed)for Style Y(Class B) NAC; system capable of 1.9 ki2-22 kS2 required.) ELR range. Refer to the Fire-Lite Device Compatibility Document for —PROPRIETARY(Automatic, Manual and Waterflow). listed compatible devices. —CENTRAL STATION (Automatic, Manual and Waterflow, and Two Programmable Relays and One Fixed Trouble Relay: Con- Sprinkler Supervised). tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). —OT, PSDN (Other Technologies, Packet-switched Data Net- Form-C relays, non-power-limited, non-supervised. work) —IBC 2012,IBC 2009,IBC 2006,IBC 2003, IBC 2000(Seismic). Cabinet Specifications —CBC 2007(Seismic) Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.)deep. Backbox: 19.00"(48.26 cm.) high x 16.65"(42.29 Agency Listings and Approvals cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE): 22.00" (55.88 cm.)high x 19.65"(49.91 cm.)wide. The listings and approvals below apply to the basic ES-50X control panel. In some cases, certain modules may not be listed by certain Shipping Specifications approval agencies, or listing may be in process. Consult factory for latest listing status. Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high • UL:S624 x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • FM approved • CSFM:7165-0075:0500 • FDNY:COA#6261 NOTE:See DF-60954 for ULC-listed model. AlarmNet®, Fire-Lite®Alarms, SWIFT®, and System Sensor®are registered trademarks of Honeywell International Inc.Microsoft®and Windows®are registered trademarks of the Microsoft Corporation. ©2018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001We try to keep our product information up-to-date and accurate We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. n MCIM:BINC 8 MIWIFACTIAIN& QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX (877)699-4105. Country of Origin:USA www.firelite.com Page 4 of 4—DF-60953:C•7/16/2018 DF-52310:A2•D-050 FCPS-24FS8 Fire LITe Alarms 8-Amp, 24 Volt Power Supply by Honeywell Power Supplies/Accessories General The Fire•Lite FCPS-24FS8(C/E) is a compact, cost-effec- tive, 8-amp remote power supplies with battery charger. The FOPS-24FS8C/E) may be connected to any 12 or 24 volt fire alarm control panel(FACP)or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries.The FCPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module) or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detec- tors. The FFCPS-24FS8(C/E) also contains a battery charger ... capable of charging up to 18.0 Amp hour batteries. FOPS- 24FS8C/E)is ULC-listed. NOTE:Unless otherwise specified, the term FCPS-24FS8 used in this document refers to the standard FCPS-24FS8, FCPS- 24FS8C, FCPS-24FS8E Features • UL-Listed Notification Appliance Circuit(NAC)synchroniza- tion using System Sensor, Wheelock, or Gentex "Com- mander2"appliances. • Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. • Includes integral battery charger capable of charging up to • Contains two fully-isolated input/control circuits - triggered 18 AH batteries. Cabinet capable of housing 7.0 AH batter- from FACP NAC (NAC expander mode) or jumped perma- ies. nently"ON"(stand-alone mode). • Battery charger may be disabled via DIP switch for applica- • Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 tions requiring larger batteries. module)NACs(circuits 1 &3) • Fixed, clamp-type terminal blocks accommodate up to 12 • 8-amp full load output, with 3 amps maximum/circuit, in AWG(3.1 mm2)wire. NAC expander mode(UL 864). • 6-amp continuous output in stand-alone mode(UL 1481). Specifications • Compatible with coded inputs; signals passed through. Primary(AC)Power: • Optional power-supervision relay(EOLR-1). • FCPS-24FS8: 120 VAC,60 Hz,3.2A maximum. • In stand-alone mode, output power circuits may be contig- • FCPS-24FS8/E: 240 VAC, 50 Hz, 1.6A maximum. ured as: resettable, (reset line from FACP required), • Wire Size: minimum#14 AWG (2.0mm2)with 600 V insula- non-resettable,or a mix of two and two. tion. • Fully regulated and filtered power output-optimal for pow- Control Input Circuit: ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. • Trigger Input Voltage: 9 to 32 VDC. • Power-limiting technology meets UL power-limiting require- • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 ments. - 16 V). • Form-C normally-closed trouble relay. Trouble Contact Rating: 5 A at 24 VDC. • Fully supervised power supply, battery,and NACs. Auxiliary Power Output: Specific application power 500 mA • Selectable earth fault detection. maximum. • AC trouble report selectable for immediate 2-hour delay. Output Circuits: • Works with virtually any UL 864 fire alarm control which uti- • +24 VDC filtered, regulated. lizes an industry-standard reverse-polarity notification cir- • 3.0 A maximum for any one circuit. cuit(including unfiltered and unregulated bell power). • Requires input trigger voltage of 9 32 VDC. • Total continuous current for all outputs(stand-alone mode): • Self-contained in compact, locking cabinet- 15"H x 14.5"W —FCPS-24FS8: 6.0 A maximum. x 2.75"D(cm:38.1 H x 36.83W x 6.985D). • Total short-term current for all outputs(NAC expander mode): —FCPS-24FS8: 8.0 A maximum. DF-52310:A2.5/17/13—Page 1 of 4 Secondary Power(Battery)Charging Circuit: Agency Listings and Approvals • Supports lead-acid batteries only. These listings and approvals apply to the modules specified in • Float-charge voltage: 27.6 VDC. this document. In some cases,certain modules or applications • Maximum current charge: 250 mA. may not be listed by certain approval agencies, or listing may • Maximum battery capacity: 7.0 AH. be in process.Consult factory for latest listing status. • UL Listed: S2424 Applications • ULC Listed:S2424 • Example 1: Expand notification appliance power an additional CSFM Approved: 7315-0075:206 8.0 A. Use up to four Class B(Style Y)outputs or four Class A • MEA:219-02E (Style Z)outputs(using ZNAC-4). For example,the FACP noti- • fication appliance circuits will activate the FCPS when reverse- Ordering Information polarity activation occurs.Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. FCPS-24FS8: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, e Example 2: Use the FCPS to expand auxiliary regulated 24- (15"H x 14.5"W x 2.75"D[cm: 38.1H 36.83 . 5D]),and volt system power up to 6.0 A. Both resettable and non-reset- installation instructions. table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one I FCPS-24FS8 is ULC listed. or both of the FCPS inputs. FCPS-24FS8E: 6.0 A,240 VAC remote charger power supply. Example 3: Use addressable control modules to activate the Includes main printed circuit board, transformers, enclosure FCPS instead of activating it through the FACP notification (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and appliance circuits.This typically allows for mounting the FCPS installation instructions. at greater distances* away from the FACP while expanding ZNAC-4: Class A(Style Y)NAC option module. system architecture in various applications. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire For example, an addressable control module is used to acti- smoke detector power. vate the FCPS,and an addressable monitor module is used to BAT-1270: Battery, 12-volt,7.0 AH (two required). sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control PS-1270: Battery, 12-volt,7.0 AH(two required). module. 90286: Optional module mounting kit, is required to install an *NOTE: Addressable FACPs are capable of locating control and addressable module on the power supply main circuit board. monitor modules at distances of up to 10,000 feet(3,046 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24FS8 can track(i.e."follow")the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24FS8 is configured(via DIP switch settings) as a"sync follower,'the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24FS8 is configured (via DIP switch settings) as a"sync generator,"the FCPS's sync input terminals are not used. Rather,the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In "sync genera- tor" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24FS8 complies with the following standards: • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). • UL 1481 Power Supplies for Fire Alarm Systems. Page 2 of 4—DF-52310:A2.5/17/13 NOTE:All NAC outputs can be converted to Style Z with Style Y NAC or ZNAC-4 option module. FCPS Door Holder Trouble Power Style Y NAC Style Y NAC Style Y NAC Contact Output#4 Output#3 Output#2 Output#1 Output 24 VDC min* Specific Application Power AC 11•1 , NAC Control Power Alma Input#2 INPUT/OUTPUT (from FACP) FUNCTIONS are programmable by NAC Control SW1 DIP switch settings , 11111111 Input#1 (from FACP) ,u Sync Input FCPS Battery Charger Simplified Block Diagram DF-52310:A2•5/17/13—Page 3 of 4 It e I'd' is c o a O N `..4. C U = r a E C N Q.co N "O U o 7 o N > j �T a 9 m'?ti' t:, o E > c 5 a a k 3 a O T C .LL G N . irj E,U U N O 2 U Q C C Q, O O 2 LL O U O a O d U 5 o U ¢ . m m E FUc voa Qv •-�Zm •x •x c c c c c y0 E E 3 ..�"o rZj c 00 ¢ ¢ U U O O U U N to ti R O Z o U m 1`oL y y 2 5 i;.�o a o I + I + I + I + I + 04g- I- ¢j X00.2. -)U -,U- O.2 II O O `r /n� e m d,,:0,,,,_ a®a e o �' N molt`imit ionot itot 1 C = O) N O h N (hC , O 0A a. c4 •• IY`� t� C ak 3 C= 7•U O ❑ = 0a� v -rg to UU + 1AA Q�Q ZZ NN u r = = CN D_ 3 UU + I >> .. m Q Q 0,, N > O a_ ZZ » + m NLLCI 00 av m UU >5 Mme zz OO a., U U EZ'e zz o a O 0 Z - E E E ti 2,.t. N _ 2,- u _ o a�'as c o m o r:i arro cy`aap¢ CO 7e4.0.4 000 O o�°��a �m3n to 0 0 E 0 H N LL F O (((�.., 1..r) © .o.ir1- Z m OO ac>° oat O J<COmzU m 00 Ih T2 I 01 1 md 10 j o o m m U U w w 2, Z, 7,- E m w Q Q °' mm d m E 3 J 0 m I ® a o o 0 �) m + y m> ~ I 1 a .. LLo Q- I + 3N I®I III Z» ..Be d ❑ ma= 4 C Q 1®1 m -, -, LLm�F o o ❑ c -3 Z ro ❑ ❑ ❑❑❑ ❑ ❑ ❑❑❑ 0 e "= a e0 Board Layout System Sensor® and FireLite® Alarms are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. ':` We try to keep our product information up-to-date and accurate. : .... C E R T.F I E O We cannot cover all specific applications or anticipate all requirements. MERIN SMAMIFAC11IIMi All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com 9 Page 4 of 4—DF-52310:A2.5/17/13 6 ATA , . . ---.„... ,........_,,... „„ .., .... , , CELLULA ALARM TG - 7FS COMMUNRICATOR TELGUARD LTE -A FOR LTE NETWORKS; VIAETEK • COMMERCIAL FIRE t PRODUCT FEATURES F Certified for use on the AT&T LTE network for sunset-free installations. F Meets UL 864 requirements for sole, primary or backup path communications. 4 P Minimizes false alarms by providing dual paths for self-tests. .. _ .._ ....,„._ -- F Falls back to 3G/4G if an LTE network is not available, for extended network coverage. .. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications :.,- solution for commercial fire systems. The TG-7FS LTE-A transmits "--.) alarm signals from the fire panel over the digital cellular network to the 4' r, . designated monitoring station. '{ t,, Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS t.` LTE-A can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the r master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-A because of the new five or sixty minute supervision modes. The TG-7FS LTE-A can also be installed as a backup path and upgraded to sole path at a later date. Telguard Portal Telguard Cell lar ServIpe °dvanced Reliability Telguard makes adopting cellular Telguard Celluh tri ce bi:f.. ' Features the ability to utilize easy with a secure Internet portal. AT&T LTE network coverage for ,multiple cellular technologies to The straightforward web interface all Telguard units. Telguard s "'} ,'increase availability and reduce allows security dealers and central Communication Center is UL =, false alarms. stations to quickly and efficiently compliant and provides seamless Automatic self-tests with central access Telguard based services 24/7. connectivity between the alarm '..station notification ensure the This advanced tool has multi-level panel,the Telguard family of " ' ellular system is operating. user authorization and provides products and the central station. total account management of Telguard Technical Support provides r Available relay output for tripping UL Listed Telguard cellular alarm a single point of contact for both ;{the alarm control panel when a i trouble condition occurs. communicators. cellular service and Telguard rodup '` questions. a a AU CELLULA ALARM 1( ,,, „ j. `£ TG - 7FS COMMUNICATOR TELGUARDTELGUARD LTE - A FOR LTE NETWORKS VIAETEK Power lc • Transmit Power: (a I>) 200 mW in all bands. ,4LTE ,k ^^�m' 1 IWI • Power Consumption: 1.1 40mA(Standby) A�a,ma^e� TOTFS 1 LTE-A 160mA(Transmission)with link 11 supervision enabled. • Source:12VAC,800mA UL listed plug-in transformer(included). Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for ,. adio Transceiver superior in-building penetration. • LTE Bands:2, 4&17. Telguard products are easy to install, economical, and UL Listed. • 3G Bands:2&5. • Antenna: 9"dipole with 2dBi gain Accessories 12 ft of cable and universal mounting bracket. • ACD 12, ACD 35, ACD 50, ACD 100: • FCC part 15,22,24,27 and 68 12/35/50/100 feet of low loss, high performance cable. compliant. • HGD-0: High gain directional antenna. • EXD-0: External antenna. Physical Details • TG-7FS LTE-A: 7.5"H x 11.5"W x 3.5"D. • Shipping Weight: Bibs. • Operating Environment: 0°C to+50°C;up to 95%humidity UL Listings Commercial Fire Commercial Burglary Residential (non condensing). 864 • Control units& 365 • Police Station 985 • Household fire accessories for fire connected burglar warning systems alarm systems alarm units and 1023• Household burglar Standard Features systems alarm systems 1610 • Central station burglar • Full data reporting alarm units; Line security servcies • Automatic self-test ULC Listings (5 or 60 minute,and daily). S545 • Canadian household fire warning systems • Locking,red metal enclosure. S304 • Canadian commercial burglary alarm systems • Two programmable supervisory 4 S559 • Equipment for fire signal receiving centres and systems C0123• Canadian household burglary alarm systems trip outputs. * For the most current product specifications and UL Listings visit www.Telguard.com. • Alarm format support for SIA2, Contact ID,pulse(3x1,4x2), SECURITY ,,,,....4 s (471 = I/// modem Ile,& Illaz, DMP. SIGNALING :: \I ELECTRONIC "�J... • Telephone line monitor built-in, O 1 ` 1 / SECURITY � '. C L US + % ASSOCIATION" - with Standard Line Security. 4W,:fell NFPA I/Ih Ex- S-r31-£lc Path,er Connected LISTED INTERNATIONAL Gold by AT&T r Telguard,a Division of Telular Corporation•3225 Cumberland Blvd SE•Suite 300•Atlanta,GA 30339•USA it 800.229.2326 I telguard.com•Copyright©2019 Telguard,a Business Unit of AMETEK,Inc.•All Rights Reserved o�za9;ax WIRE REQUIREMENTS:POWER CIRCUIT Agency Listings and Approvals • 14 to 18 AWG(0.75-2.08 mm2)wire for 24 VDC power circuit is The listings and approvals below apply to the ANN-80. In some acceptable. Power wire distance limitation is set by 1.2 volt maxi- cases, certain modules may not be listed by certain approval agen- mum line drop form source to end of circuit. cies, or listing may be in process. Consult factory for latest listing • All connections are power-limited and supervised. status. • A maximum of eight ANN-80 modules may be connected to this • UL: S2424 circuit. / • FM approved Ordering Options (/G • CSFM: 7120-0075:0211 (ANN-80:Red 80 character LCD Annunciator. • MEA:442-06-EI ANN-80-W:White,80 character LCD Annunciator. • ANN-SB8OKIT-R: Red surface mount backbox with angled wedge. ANN-SB8OKIT-W: White surface mount backbox with angled wedge. Fire-Lite®Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. '�O �oo� We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. CERTIFIEEI BYU A L INE 6 MAY S T EM S For more information,contact Fire•Lite Alarms. Phone:(800)627-3473,FAX:(877)699-4105. QUALITY SYSTEMSCountry of Origin:USA www.firelite.com Page 2 of 2—DF-52417:D•3/15/2018 0 (teSFDB • • FIRE DOCUMENT BOX The FDB is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this FIRE, ALARM DOCAMENTS product allows you to do just that. NFPA 72 2010 Records f Programs I Software section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. Along with your fire alarm software you can store your test & inspection documents, service records, manuals & AS built drawings for the system. The FDB is designed to hold critical manuals and Standard Features: documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and • 2 Key ring hooks to hold system keys reference. Inside the cover it has a organized note • Business card holder for key contacts table that allows for documentation for passwords • Overall Dimensions are 12" x 13" tall and 2 1/4 deep and other critical system information. • 16 gauge steel box and cover for security • Durable powercoat baked on finish other colors available • Standard3/"cat 30 key lock other lock as- semblies available • Solid stainless steel piano hinge • Permanently screened white ink 1" high "Fire Alarm Documents" • Legend sheet for passwords and system information /=✓ !r ISO 9001 • I W. .., ���■�� REGISTERED COMPANY Space Age Electronics, Inc. www.lsae.com ADA 800.486.1723 Toll Free NFPA Made In U.S.A. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2013 No Excuses, Just Solutions! ED0447 LT10505 Rev.B 1/2 ___„/ SPACE AGE � _ �. ..ww� u .t....�.., �,�W. ELECTRONICS, INC. Specifications: The fire alarm documents box (FDB) shall be constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS " with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. $ $ Property Information Minimum Requited Documentation(SIG-FUN) Ring Key .u..... .wen axo E,. Lout. m m . ..$' ..1. .... .._ onp OYmwop.M.. R.a w M Hooks �< 161 Satlons antl AP nConl,w. uu▪wm�• ro..+«ro<.m�aa a.mesam ca^oi.v+w w^ r6w.1 Syslem Install t C M lr ,, ut«.m� °.rf^<tom.°v p°nrvmn °$•▪wn^•ewo�. Or�.w.,..m4ai sre� 1A: Pr Med namee ea1,1/A IDnRw End*a At Lor. Business � �a�w "w�a�w ww.a^.�Nwwe. • Phonea �o Eero.ea a l Mrs twa- ww 555... - Card Holder 16.5 Auth tyH gJ 'dM' ditlo^p^ "1a1 isgn/ti AGF, In accordance we rts appoved plans or,.w.,°m..a li„ksta0 em wc^ahere. t �'. I ndosed Or AL tocaton Pronetle Equipment Informationt. o•awk..a aro, 1 sxi ,. oRxerc va°^ a%.a'o�Alt m��e^r<.m<un.mnw�m°«ora.i,w..mm s.<a.�s a; iso rvo,.. mow...En... Lout. ID No u .°R...wad reel .amm.o.,.,a m^. ,. accordance., ac, e., - .rial En..Or AIL Location �. .. _ .. J Spew>ae Eiewaniw,icc. se cnackua Rom s^amp,w7nm5aa RmaeR.t�zf wxxt°aewm 1T10ad4 Rer 1 Legend sheet for storing system information including contacts,sign-off,maintenance & test information,and alternate locations of additional records. Ordering Information: Part # Description A /ir SSU00672 Fire Document Box RED BOX Space Age Electronics, Inc. SSU00673 Custom screening with your Logo www.l sae.com 800.486.1723 Toll Free Check out our Infinity line eFAD single gang 2 Gig digital storage 508.485.0966 Local solutions (IAMEFAD) 508 485 4740 Fax This document is subject to change without notice,see doc#ED0479 for legal disclaimer No Excuses, Just Solutions! ED0447 LT10505 Rev.B 2/2 " DF-52013:D•E-100 BG-12LX Flre•LITeALarms Addressable Manual Pull Station by Honeywell Addressable Devices General The Fire•Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire•Lite's addressable fire alarm control panels (FACPs) F IRE Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station.This leads fire personnel quickly to the location of the alarm. Features I PUSH IN • Maintenance personnel can open station for inspection and PULL DOWN address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to enrf LITe Adan-nS SLC loop(accepts up to 12 AWG/3.25 mm2 wire). by Honeywell • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang,or 4" (10.16 cm)square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- LL lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • • Highly visible. usually needed for semi-flush mounting with 4" (10.16 cm) or • Attractive shape and textured finish. double-gang boxes(not with single-gang boxes). • Key reset. Includes Braille text on station handle. Operation • Optional trim ring(BG12TR). Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 — • Shipping Weight: 9.6 oz. (272.15 g) 99 and MS-92000DLS, 1 —50 for MS-9050UD). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 pA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The BG-12LX will mount semi-flush into a single-gang,double- appear instructions provided on the cover. The word FIRE shall gang,or standard 4"(10.16 cm)square electrical outlet box,or appear on the front of the stations in white letters, 1.00 inches • will surface mount to the model SB-10 or SB-I/O surface back- (2.54 cm) or larger. Stations shall be suitable for surface box. If the BG-12LX is being semi flush mounted, then the mounting on matching backbox SB-10 or SB-I/O;or semi-flush optional trim ring (BG12TR) may be used. The BG12TR is mounting on a standard single gang, double gang, or 4"(10.16 cm) square electrical box, and shall be installed DF-52013:D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10:Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR:Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL/ULC Listed: S711 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E. • CS FM:7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLite®Alarms®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. E ' }'u. . .. .`T,Sac,,n t :x;..•H4+_`c..x.:...'.;3 i:&ub,�'i$i#?.-"'... vim--r is.. 'k€�.:'£._ `,.Stvya .�y.�..; $ice'..¢.:. .6e'U", de'�G +`.' -°.xc.:. '�O 9001 This document is not intended to be used for installation purposes. MN We try to keep our product information up-to-date and accurate. C E R T I F 1 E U We cannot cover all specific applications or anticipate all requirements. --, � EN6INEEIINI B MMIFACTIAIN& All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-52013:D•4/13/2012 D1--61010: SD365 Series 6:1•0Addressable Photoelectric Smoke Detectors Flre-uTe�ALarms by Honeywell Addressable Devices ' The Fire•Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelli-gent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SD355 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire•Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary,decimal address switches,provid- ing exact detector location for emergency personnel to quickly ( 1 locate a fire during its early stages, potentially saving precious res- cue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A)and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features • Plugs into separate base for ease of installation and maintenance SLC LOOP: • Separate base allows interchange of photoelectric, ionization and • Two-wire SLC loop connection thermal sensors • Unit uses base for wiring OPTIONS: • Compatible with LiteSpeedTA9 and CLIP protocol systems • Optional relay, isolator, and sounder bases • Stable communication technique with noise immunity Installation ADDRESSING: SD365 Series plug-in intelligent smoke detectors use a detachable • • Addressable by device base to simplify installation, service and maintenance. Installation • Rotary,decimal addressing instructions are shipped with each detector. (Refer to the Fire•Lite panel manuals for device capacity.) Mount detector base(all base types)on an electrical backbox which ARCHITECTURE: is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes,see DF-60059. • Sleek, low-profile, stylish design single source design to respond quickly and dependably NOTE:Because of the inherent supervision provided by the SLC loop, • Unique to a broue siranges ffires end-of-line resistors are not required. Wiring "T-taps"or branches are permitted for Style 4(Class"B")wiring only. • Integral communications and built-in device-type identification When using relay or sounder bases, consult the 1300(A) installation • Built-in tamper resistant feature sheet 156-3626 for device limitations between isolator modules and iso- lator bases. • Remote test feature from the panel • Walk test with address display (an address on 121 will blink the Construction detector LED. 12-[pause] 1(LiteSpeed systems only) These detectors are constructed of fire-resistant plastic. The SD365 • Built-in functional test switch activated by external magnet Series plug-in intelligent smoke detectors are designed to commer- • Removable cover and insect-resistant screen for simple field cial standards and offer an attractive appearance. cleaning • Expanded color options Operation Each SD365 Series detector uses one of the panel's addresses OPERATION: (total limit is panel dependent)on the Fire•Lite Signaling Line Circuit • Designed to meet UL 268 7th Edition (SLC). It responds to regular polls from the control panel and reports • Factory preset at 1.5% nominal sensitivity for panel alarm thresh- its type and the status. If it receives a test command from the panel old level (or a local magnet test), it stimulates its electronics and reports an • LED "blinks"when the unit is polled (communicating with the fire alarm. It blinks its LEDs when polled and turns the LEDs on when panel)and latches in alarm. commanded by the panel. The SD365 Series offers features and performance that represent the latest in smoke detector technology. • Low standby current Detector Sensitivity Test MECHANICALS: • Sealed against back pressure Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance)when installed/ • SEMS screws for wiring of the separate base connected to an Fire•Lite addressable fire alarm control panel. The • Designed for direct-surface or electrical-box mounting results of the sensitivity test can be printed for record keeping. OF-61010:B•71/2019—Page 1 of 3 Product Line Information B200SA-WH:Same as B200S-WH, ULC listing NOTE:"-IV"suffix indicates CLIP and LiteSpeed device. B200SA-IV:Same as B200S-IV, ULC listing NOTE:A"suffix indicates Canadian version. White, Intelligent, programmable sounder base in SD365:White, low-profile intelligent photoelectric sensor, LiteSpeed(A200SCOA-WH: 1•nglish/French (required in Canada for ULC applications with CO Series detector applications only B200SCOA-IV: Ivory Intelligent, programmable sounder base in SD365A: Same as SD365 but with ULC listing English/French (required in Canada for ULC applications with CO SD365-IV: Ivory, low-profile intelligent photoelectric sensor Series detector applications, ULC listing SD365A-IV: Same as SD365-IV but with ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- SD365T:White,same as SD365 but includes a built-in 135°F(57°C) 10% with a square wave or its equivalent; designed to meet the - fixed-temperature thermal device, LiteSpeed only NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) SD365TA:Same as SD365T but with ULC listing B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable SD365T-IV: Ivory, same as SD365T but includes a built-in 135°F sounder base. Produces a fundamental frequency of 520 Hz +/- (57°C)fixed temperature thermal device 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) SD365TA-IV: Same as SD365T-IV but with ULC listing B200SR-WH:White, Intelligent sounder base capable of producing SD365R: White, low-profile intelligent photoelectric sensor, remote sound output with ANSI Temporal 3 or continuous tone. Intended for test capable,for use with DNR/DNRW, LiteSpeed only retrofit applications. (CSFM: 7300-1653:0213) SD365RA: Same as SD365R but with ULC listing, for use with B200SR-IV: Ivory, Intelligent sounder base capable of producing DNRA sound output with ANSI Temporal 3 or continuous tone. Intended for SD365R-IV: Ivory, low-profile intelligent photoelectric sensor,remote retrofit applications. (CSFM: 7300-1653:0213) test capable,for use with DNR/DNRW B200SRA-WH:Same as B200SR-WH with, ULC listing SD365RA-IV: Same as SD365R-IV but with ULC listing,for use with B200SRA-IV:Same as B200SR-IV in Ivory color, ULC listing DNRA B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- INTELLIGENT BASES 10% with a square wave or its equivalent; designed to meet the NOTE:For details on intelligent bases,see DF-60059. NFPA 72 sleeping space requirement. Intended for retrofit applica- B300-6:White,6"base, standard flanged low-profile mounting base tions. (CSFM: 7300-1653:0238) (CSFM: 7300-1653:0109) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable B300-6-IV: Ivory,6" base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base(CSFM: 7300-1653:0109) 10% with a square wave or its equivalent; designed to meet the 6300A-6:Same as B300-6, ULC listed NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed MOUNTING KITS AND ACCESSORIES B300-6-BP: Bulk pack of B300-6, package contains 10 TR300:White, replacement flange for B210LP(A)base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B210LP(A)base base. UUULC listed(CSFM: 7300-1653:0109) RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single-gang electrical box. For use with B501(A)and B300-6(A). UL/ULC listed(CSFM: 7300-1653:0109) M02-04-00:Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting M02-09-00:Test magnet with telescoping handle base. UUULC listed (CSFM: 7300-1653:0109) CK300:Color Kit(includes cover and trim ring),white, 10-pack B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 CK300-IV: Color Kit(includes cover and trim ring), ivory, 10-pack B224RB-WH:White, relay base(CSFM: 7300-1653:0216) CK300-BL:Color Kit(includes cover and trim ring), black, 10-pack B224RB-IV: Ivory, relay base(CSFM: 7300-1653:0216) B224RBA-WH:White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B22461-WH:White, isolator detector base(CSFM:7300-1653:0216) B224BI-IV: Ivory isolator detector base(CSFM: 7300-1653:0216) B224BIA-WH:White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B200S-WH:White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone, marching tone,and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) Page 2 of 3—DF-61010:B•71/2019 SYSTEM SPECIFICATIONS Sensitivity: Listings and Approvals • UL Applications:0.5%to 4.0%per foot obscuration. Listings and approvals below apply to the SD365 Series detectors. • ULC Applications:0.5%to 3.5%per foot obscuration In some cases, certain modules may not be listed by certain Size:2.0"(5.3 cm)high; base determines diameter approval agencies, or listing may be in process. Consult factory for latest listing status. —B300-6:6.1"(15.6 cm)diameter • —B501:4"(10.2 cm)diameter UL/ULC Listing:S1059 • For a complete list of detector bases see DF-60983 FM Approved • CSFM:7272-0075:0502 Shipping weight:3.4 oz. (95 g) Operating temperature range: • SD365:32°F to 122°F(0°C to 50°C) • SD365T Series: 32°F to 100°F(0°C to 38°C) • SD365R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10%—93%non-condensing Thermal ratings:fixed-temperature set point 135°F(57°C), rate-of- rise detection 15°F(8.3°C)per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") DETECTOR SPACING AND APPLICATIONS Fire•Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors • 30 feet(9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. LiteSpeedTM is a trademark, and Fire•Lite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2019 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. ENSINEEIINS A MANIEACTIMNS QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:Mexico www.firelite.com Page 3 of 3—DF-61010:B•71/2019 jNOTIFIER@ by Honeywell Intelligent Bases Standard, Relay, Isolator, Sounder, and Low-Freq en ounder Bases • General • To meet local code and application requirements, NOTIFIER®offers standard 4"and 6"bases, as well as, specialty base designs includ- ing relay, isolator, sounder and low frequency sounder options for * - /�� ' \ the new 900 Series of addressable detectors as well as previoust generations. w i 1 • • The standard 4"and 6"bases offer a plug-in detector base intended -� '--// for use in intelligent systems, with screw terminals identified with a _ (+ and –). The 4" base offers a compact design while the 6" base - provides compatibility with a wider range of junction boxes. B200S-WH B300-6 Standard The specialty bases support application driven requirements.These 6"Base(White) Sounder Base(White) bases employ a separate mounting plate that installs on various junction box sizes to eliminate unsightly surface-mount boxes. The mounting plate enables pre-wiring of all connections to speed and x�_�• simplify installation. ,; ,. . .•4;f / \\ Relay bases provide one form-C contact relay for control of auxiliary • w� functions, such as door closure and elevator recall. The relay can 1 operate in two different modes(short and long delay).The activation 1 time for the short delay is 60-100 milliseconds, while the activation ik"i • time for the long delay is 6-10 seconds.A shunt with pin headers, \ 1 . located on the base PC board, is used to set the delay timing. N / %' Isolator bases allow the Signaling Line Circuit(SLC)loop to operate �''"!'`' under fault conditions created from a short circuit preventing an B501-WHITE Flangeless B501-BL Flangeless entire communication loop from being disabled. The base isolates 4"Base(White) 4"Base(Black) the section of the loop containing the short circuit from the remain- der of the circuit and automatically restores when the fault is cor- rected. Specifications Sounder and low frequency sounder bases are designed for new NOTE:Specifications applies to all model variants'A", "-BL", "-LF", "-IV", and existing dwelling unit applications. They offer maximum flexibil- -WH, -WHITE. See Product Line Information for detailed model descrip- ity in installation, configuration, and operation to meet or exceed UL tion. 268 and UL 464 requirements. The low frequency sounder bases Diameter are designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +/- 10%with a square • 8501-WHITE:4"(10.16 cm)diameter. wave or its equivalent. Studies show that a lower frequency, cen- • B300-6:6.1"(15.49 cm)diameter. tered around 520 Hz, is the most ideal to wake sleeping occupants, • B224B1, B224RB:6.2"(15.748 cm)diameter. even those with mild to severe hearing loss. • B200S, B200SR, B200SCOA:6.875"(17.46 cm)diameter. The B200SR sounder and -LF sounder bases (B200SR-WH/ Wire gauge: B200SR-IV/B200SR-LF-WH/B200SR-LF-IV) are fully compatible with existing B501BH Series sounder base installations.The device • B224B1, B224RB: 14 to 24AWG. enables users to select one of two B501-supported tones (ANSI • B300-6, B210LP, B501, B200S, B200SR, B200SCOA: 12 to 24 Temporal 3 or Continuous)through a jumper. AWG The B200S sounder and-LF sounder bases(B200S-WH/B200S-IV/ Temperature range: B200S-LF-WH/B200S-LF-IV)adopt the same address as the detec- • B224B1, B224RB, B200S, B200SR, B200SCOA: 32°F to 120°F tor, but use a unique device type on the loop.The Fire Alarm Control (0°C to 49°C). Panel (FACP) can use that address to command an individual B300-6, B210LP, B501:-4°F to 150°F(-20°C to 66°C). sounder—or a group of sounders—to activate.The command set from the FACP can be tailored to multiple event-driven tone outputs Humidity range: 10%to 93%RH, non-condensing. allowing selection of volume(75 or 85 dBA),tone(ANSI Temporal 3, System temperature and humidity ranges: This system meets ANSI Temporal 4, or March Time) and group. In addition, some NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); FACPs will enable custom tone patterns.The B200S series sounder and at a relative humidity (non-condensing) of 85% at 30°C (86°F) bases recognize the System Sensor synchronization protocol. This per NFPA, and 93% ±2% at 32°C±2°C (89.6°F± 1.1°F) per ULC. enables them to be used as a component of the general evacuation However, the useful life of the system's standby batteries and the signal — along with other System Sensor AV appliances —when electronic components may be adversely affected by extreme tern- connected to a power supply or FACP output capable of generating perature ranges and humidity. Therefore, it is recommended that the System Sensor synchronization pulses. this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C(60°F to 80°F). DN-60054:K•7/18/2018—Page 1 of 3 Electrical Ratings Product Line Information FOR B300-6 SERIES BASES: INTELLIGENT BASES Operating voltage: 15 to 32 VDC NOTE:`A"suffix indicates ULC Listed model. Standby current: 170 pA maximum NOTE:"-IV"suffix indicates Ivory color model. FOR B501 SERIES BASES: NOTE: "-BL"suffix indicates Black color model. Operating voltage: 15 to 32 VDC NOTE: "-WH"and"-WHITE"suffix indicates White color model. Standby current: 150 pA maximum B210LP: Flanged mounted base. B210LPA:Same as B210LP; ULC listed. FOR B200 SERIES BASES: B210LPBP:Bulk pack of B210LP, contains 10. External supply voltage: 16 to 33 VDC(FWR) B300-6:White,6"base,standard flanged low-profile mounting base. Standby current: 500 pA maximum. B300A-6: Same as B300-6, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10;. Alarm current: B300-6-IV: Ivory,6" base, standard flanged low-profile mounting • B200S(A)(-IV)(-WH) base. —35 mA maximum at high-volume setting B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, —15 mA maximum at low-volume setting ULC listed. • B200S-LF(-IV)(-WH)High-volume setting: B501-WHITE: White, 4" standard European flangeless mounting —70 mA maximum @ 33.0 VDC base. UL/ULC listed. —90 mA maximum @ 24.0 VDC B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. —140 mA maximum @16.0 VDC B501-BL: Black, 4" standard European flangeless mounting base. • B200S-LF(-IV)(-WH)Low-volume setting: UL/ULC listed. —15 mA maximum @ 33.0 VDC B501-IV: Ivory color, 4" standard European flangeless mounting —20 mA maximum @ 24.0 VDC base. UL/ULC listed. —25 mA maximum @ 16.0 VDC B224RB-WH:White, relay base. • B200SR(A)(-IV)(-WH) B224RB-IV: Ivory, relay base. —35 mA maximum • B200SR-LF(-IV)(-WH) B224RBA-WH:White, relay base, ULC listed. —65 mA maximum @ 33.0 VDC B224RBA-IV: Ivory, relay base, ULC listed. —90 mA maximum @ 24.0 VDC B224BI-WH:White, isolator detector base. —125 mA maximum @16.0 VDC B224BI-IV: Ivory isolator detector base. • B200SCOA(-IV)(-WH) B224BIA-WH:White, isolator detector base, ULC listed. —40mA Max(DC) B224BIA-IV: Ivory isolator detector base, ULC listed. —70mA Max(FWR) B200S-WH:White, Intelligent addressable sounder base capable of SLC operating voltage: 15 to 32 VDC producing sound output in high or low volume with ANSI Temporal 3, SLC standby current: See applicable sensor specification. ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan®protocol. Sound output: B200S-IV: Ivory, Intelligent addressable sounder base capable of • B200S(A)(-LF)(-IV)(-WH), high-volume": Greater than 85 dBA producing sound output in high or low volume with ANSI Temporal 3, minimum. ANSI Temporal 4, continuous tone, marching tone,and custom tone. • B200S(A)(-LF)(-IV)(-WH), low-volume`: Greater than 75 dBA Uses FlashScan®protocol. minimum. B200SA-WH:Same as B200S-WH, ULC listed. • B200SR(A)(-LF)(-IV)(-WH)": Greater than 85 dBA minimum. B200SA-IV:Same as B200S-IV, ULC listed. • B200SCOA(-IV)(-WH), high-volume": Greater than 87 dBA mini- B200SCOA-WH: White, Intelligent, programmable sounder base in mum. English/French (required in Canada for ULC applications with SO • B200SCOA(-IV)(-WH), low-volume"": Greater than 85 dBA mini- Series detector applications. mum `Measured in a UL reverberant room at 10 feet,24 Volts(continuous tone) B200SCOA-IV: Ivory Intelligent, programmable sounder base in "Measured in a ULC anechoic room at 10 feet,24 Volts continuous tone) English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. FOR 822461, B224RB(A)(-IV)(-WH): B200S-LF-WH: White, Low Frequency Intelligent, programmable Operating voltage: 15 to 32 VDC(powered by SLC) sounder base. Produces a fundamental frequency of 520 Hz +/- Standby ratings: <450 pA maximum @ 24 VDC 10% with a square wave or its equivalent; designed to meet the Set time(B224RB(A)(-IV)(-WH)only): short delay 60-100 millisec NFPA 72 sleeping space requirement. onds; long delay 6-10 seconds B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- Reset time(B224RB(A)(-IV)(-WH)only):20 milliseconds maximum 10% with a square wave or its equivalent; designed to meet the • Relay characteristics(B224RB(A)(-IV)(-WH)only): two-coil latch- NFPA 72 sleeping space requirement. ing relay; one Form-C contact; ratings(UL/CSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0 A @ 30 VDC Page 2 of 3—DN-60054:K•7/18/2018 B200SR-WH:White, Intelligent sounder base capable of producing M02-04-00:Test magnet. sound output with ANSI Temporal 3 or continuous tone. Intended for M02-09-00:Test magnet with telescoping handle. retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing CK300:White,detector color kit. Pack of 10. sound output with ANSI Temporal 3 or continuous tone. Intended for CK300-IR: White, detector color kit for use with FPTI and FCO retrofit applications. Series detectors. Pack of 10. B200SRA-WH: Same as B200SR-WH, ULC listed. CK300-IV: Ivory,detector color kit. Pack of 10. B200SRA-IV:Same as B200SR-IV in Ivory color, ULC listed. CK300-IR-IV: Ivory, detector color kit for use with FPTI and FCO - B200SR-LF-WH: White, Low Frequency Intelligent, programmable Series detectors. Pack of 10. sounder base. Produces a fundamental frequency of 520 Hz +/- CK300-BL: Black,detector color kit. Pack of 10. 10% with a square wave or its equivalent; designed to meet the CK300-IR-BL: Black, detector color kit for use with FPTI and FCO ' NFPA 72 sleeping space requirement. Intended for retrofit applica- Series detectors. Pack of 10. tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable Agency Listings and Approvals sounder base. Produces a fundamental frequency of 520 Hz +/ The listings and approvals below apply to intelligent bases as noted. 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- In some cases, certain modules or applications may not be listed by tions. certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. MOUNTING KITS AND ACCESSORIES • UL/ULC Listed: S1115 TR300:White, replacement flange for B210LP(A), B300(A)-6 bases. • FM Approved TR300-IV: Ivory, replacement flange for B210LP(A), B300(A)-6-IV • CSFM: 7300-1653:0109, 7300-1653:0126, 7300-1653:0213, bases. 7300-1653:0236 RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300(A)- 6. Junction Box Selection Guide Single Double 4.0"Sq. Base Models Gang Gang 3.5"Oct. 4.0"Oct. 4.0"Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm mud ring B200S,B200SR, Yes Yes Yes Yes Yes Yes No No No No B200SCOA B501 No No Yes No No Yes Yes Yes Yes No B210LP,B300-6 Yes No Yes Yes Yes Yes No No No No B224B1,B224RB Yes Yes Yes Yes Yes Yes No No No No NOTE:Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. NOTE:Applies to all model variants'A", "-BL", "-LF", "-IV', "-WH", and"-WHITE". See Product Line Information for detailed model description. I® MCIMalf16 I MAYMECnus QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate at requirements. At specifications are subject to change without notice. NOTIFIER FlashScan®, NOTIFIER®and System Sensor®are regis- 12 Clintonville Road tered trademarks of Honeywell International Inc. /� /� F k /\v�.~�/1� Northford,CT 06472 52018 by Honeywell International Inc. All rights reserved. N OT I F If ER 203.484.7161 Unauthorized use of this document is strictly prohibited. by Honeywell O www.notifier.corn Country of Origin Mexico DF-60430:C2•E-650 D355PL(A)/DNRW InnovairFlex Flre•LITe ALaI'ms Intelligent Non-Relay Photoelectric Duct Smoke Detector by Honeywell Intelligent Addressable Devices • General The Fire•Lite InnovairFlex® D355PL(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non- - relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capa- ble of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute(0.5 to 20.32 m/s), temperatures of-4°F to 158°F(-20°C to 70°C), and a humidity range of 0 to 95 percent(non-condensing.) An improved cover design isolates the sensor head, which Specifications allows for ease of maintenance. A cover tamper feature indi- Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) cates a trouble signal for a removed or improperly installed Width,2.5 in(6.6 cm) Depth. sensor cover.The Fire•Lite InnovairFlex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir Size:(Square)7.75 in(19.7 cm)Length;9 in(22.9 cm)Width; ing and mounting of a relay module. 2.5 in(6.35 cm)Depth. The Fire•Lite InnovairFlex duct smoke detector can be custom- Weight: 1.6 lb(0.73 kg). ized to meet local codes and specifications without additional Operating Temperature Range: -4°F to 158°F (-20°C to wiring.The new InnovairFlex product line is compatible with all 70°C). previous Innovair models, including remote test accessories. Storage Temperature Range: -22°F to 158°F (-30°C to Features 70°c). Operating Humidity Range: 0% to 95% relative humidity • Photoelectric, integrated low-flow technology. (non-condensing). • Air velocity rating from 100 ft/min to 4,000 ft/min(0.5 m/s to Air Duct Velocity: 100 to 4,000 ft/min(0.5 to 20.32 m/s). 20.32 m/s). • Versatile mounting options: square or rectangular configu- Accessories ration. • Broad ranges for operating temperature (-4°F to 158°F, - Fire•Lite provides system flexibility with a variety of accesso 20°C to 70°C)and humidity(0%to 95%non-condensing). ries,including two remote test stations and different means of visible and audible system annunciation. As with our duct • Patented sampling tube installs from front or back of the smoke detectors,all duct smoke detectors accessories are UL detector with no tools required. listed. • Cover tamper signal. D355PLs and DNRWs with a date code of 0013 or higher do • Increased wiring space with a newly added 3/4" conduit not require external 24VDC for remote test applications when knockout. used with a remote-test-capable detector. • Available space within housing to accommodate mounting ACCESSORY CURRENT LOADS AT 24 VDC of a relay module. • Easily accessible code wheels on sensor head (sold sepa Device Standby Alarm rately). • Clear cover for convenient visual inspection. RA100Z OmA 12 mA Max • Remote testing capability. RTS151/ • Requires corn line power only. RTS151KEY OmA 12mA Max • Accommodates the installation of an addressable relay module, sold separately, (CRF-300) for applications requir Agency Listings and Approvals ing a Form-C relay. Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL:S1059. • ULC:S1059 DF-60430:C2•12/18/2012—Page 1 of 2 • CSFM: 3242-1653:0209. • FM approved. Product Line Information 4k D355PL: Intelligent non-relay photoelectric low flow smoke detector housinq. Includes SD355R Detector. DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Does not include detector head. SD355R(A): Remote test capable addressable low-profile photoelectric smoke detector. SD355(A):Addressable low-profile photoelectric smoke detec- tor. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1: Metal sampling tube duct width up to 1 ft(0.3m). DST1.5: Metal sampling tube duct widths up to 1 ft to 2 ft(0.3 to 0.6 m). DST3: Metal sampling tube duct widths up to 2 ft to 4 ft(0.6 to 1.2 m). DST5: Metal sampling tube duct widths up to 4 ft to 8 ft(1.2 to 2.4 m). DST10: Metal sampling tube duct widths up to 8 ft to 12 ft(2.4 to 3.7 m). DH4000E-1:Weatherproof enclosure. ETX: Metal exhaust tube duct,width 1 ft(0.3 m). M02-04-00:Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z: Remote annunciator alarm LED. t / RTS151: Remote test station. RTS151 KEY: Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Fire•Lite®Alarms is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEEIINC 8 MANIFACTIIIN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—DF-60430:C2•12/18/2012 DF-52121:E•E-325 MMF-300(A) Series, MDF-300 Flre-LITeALarms Addressable Monitor Modules by Honeywell Addressable Devices". General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices,such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors "" (MMF-302(A)). t • BC.t.Ali ALARM •Et-r. MMF-300(A)is a standard-sized module(typically mounts to a °) aSLC T1 -, 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input '°°"'` devices. PAT 100 5311/)69 MMF-301(A)is a miniature monitor module a mere 1.3"(3.302 as cm) Hx2.75" (6.985cm)Wx0.65" (1.651 cm) Dthatsuper- frr. vises a Style B(Class B)circuit of dry-contact input devices. Its , compact design allows the MMF-301(A) to be mounted in a single gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and41. supervise compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. MDF-300(A)is a standard-sized dual monitor module used to MMF-300(A)(Type H) monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B (Class B)or Style D (Class tems. A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTM is a communication protocol developed by (provided)terminates the Style B circuit. No resistor is required Fire•Lite Engineering that greatly increases the speed of com- for supervision of the Style D circuit. munication between analog intelligent devices. Intelligent MMF-300(A) OPERATION devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU Each MMF-300(A) uses one of the available module stops the group poll and concentrates on single points. The addresses on an SLC loop. It responds to regular polls from net effect is response speed greater than five times that of the control panel and reports its type and the status(open/nor- other communication protocols. mal/short)of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control MMF-300(A) Monitor Module panel. The LED latches steady on alarm (subject to current limitations on the loop). • Built-in type identification automatically identifies this device as a monitor module to the control panel. MMF-300(A)SPECIFICATIONS • Powered directly by two-wire SLC loop. No additional Nominal operating voltage: 15 to 32 VDC. power required. Maximum current draw:5.0 mA(LED on). • High noise(EMF/RFI)immunity. Average operating current: 375 pA (LED flashing), 1 corn- • SEMS screws with clamping plates for ease of wiring. munication every 5 seconds,47k EOL. • Direct-dial entry of address: 01 — 159 on MS-9600 series Maximum IDC wiring resistance: 1500 Ohms. panels, 01 —99 on other compatible systems. • LED flashes during normal operation and latches on steady Maximum IDC Voltage: 11 Volts. to indicate alarm. EOL resistance:47K Ohms. The MMF-300(A) Monitor Module is intended for use in intelli- Temperature range: 32°F to 120°F(0°C to 49°C). gent, two-wire systems, where the individual address of each Humidity range: 10%to 93% noncondensing. module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Device Circuit (IDC) for normally-open-contact fire alarm and 1.25" (3 175 cm) deep. Mounts to a 4" (10.16 cm) square x supervisory devices. The module has a panel-controlled LED 2.125"(5.398 cm)deep box. indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-3O1(A) Mini Monitor Module MMF-300(A)APPLICATIONS • Built-in type identification automatically identifies this device Use to monitor a zone of four-wire smoke detectors, manual as a monitor module to the panel. fire alarm pull stations, waterflow devices, or other normally- • Powered directly by two-wire SLC loop. No additional open dry-contact alarm activation devices. May also be used power required. to monitor normally-open supervisory devices with special • High noise(EMF/RFI) immunity. DF-52121:E•07/30/2015—Page 1 of 4 • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct-dial entry of address: 01 — 159 on MS-9600 series source. panels, 01 —99 on other compatible systems • High noise(EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. 3 1415 0 1 ADDRESS 0 1 • Direct-dial entry entry of address: 01 — 159 on MS-9600 13 I 2 �, 2 series panels,01 —99 on other compatible systems. 3 �� 4 LOOP �� 3 •• LED flashes during normal operation. • LED latches steady to indicate alarm on command from • control panel. 10 9 8 7 6 5 9 $ 7 e 5 The MMF-302(A)Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of • each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status I— Y (normal, open, or alarm) of one full zone of conventional — LU Q detectors back to the control panel. All two-wire detectors } 0 --1 being monitored must be UL compatible with the module. The MMF 302(A) can be used to replace M302(A) modules in existing systems. MMF-302(A)APPLICATIONS II I Use the MMF-302(A) to monitor a zone of two-wire smoke The MMF-301(A) Mini Monitor Module can be installed in a detectors. The monitored circuit may be wired as an NFPA single-gang junction directly behind the monitored unit. Its Style B(Class B)or Style D(Class A) Initiating Device Circuit. small size and light weight allow it to be installed without rigid A 3.9 K Ohm End-of-Line Resistor (provided) terminates the mounting. The MMF-301(A) is intended for use in intelligent, end of the Style B or D (class B or A) circuit (maximum IDC two-wire systems where the individual address of each module loop resistance is 25 Ohms). Install ELR across terminals 8 is selected using rotary switches. It provides a two-wire initiat- and 9 for Style D application. ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A)can be used to replace M301(A) modules in MMF-302(A) OPERATION existing systems. Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from MMF-301(A)APPLICATIONS the control panel and reports its type and the status(open/nor- Use to monitor a single device or a zone of four-wire smoke mal/short)of its Initiating Device Circuit(IDC). A flashing LED detectors, manual fire alarm pull stations, waterflow devices, indicates that the module is in communication with the control or other normally-open dry-contact devices. May also be used panel. The LED latches steady on alarm (subject to current to monitor normally-open supervisory devices with special limitations on the loop). - supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B(Class B) Initiating Device MMF-302(A)SPECIFICATIONS Circuit.A 47K Ohm End-of-Line Resistor(provided)terminates Nominal operating voltage: 15 to 32 VDC. the circuit. Maximum current draw: 5.1 mA(LED on). MMF-301(A) OPERATION Maximum IDC wiring resistance: 25 Ohms. Each MMF-301(A) uses one of the available module Average operating current: 270 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). EOL resistance: 3.9K Ohms. MMF-301(A)SPECIFICATIONSExternal supply voltage(between Terminals T10 and T11): • Nominal operating voltage: 15 to 32 VDC. DC voltage. 24 volts power limited. Average operating current: 350 pA, 1 communication every • Ripple voltage:0.1 Vrms maximum. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC • Current. 90 mA per module maximum. Shorted). Temperature range: 32°F to 120°F(0°C to 49°C). Maximum IDC wiring resistance: 1500 Ohms. Humidity range: 10%to 93%noncondensing. Maximum IDC Voltage: 11 Volts. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC Current:450 NA. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F(0°C to 49°C). MDF-300(A) Dual Monitor Module Humidity range: 10%to 93% noncondensing. The MDF-300(A) Dual Monitor Module is intended for use in Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x intelligent, two-wire systems. It provides two independent two- 0.65"(1.651 cm)deep. wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire Wire length:6"(15.24 cm)minimum. alarm and supervisory devices.The module has a single panel- controlled LED. _ MMF-302(A) Interface Module • Supports compatible two-wire smoke detectors. 11111111111101111111. ^ Page 2 of 4—DF-52121:E•07/30/2015 NOTE: The MDF-300(A)provides two Style B (Class B) IDC cir- MDF-300(A): Monitor module, dual, two independent Class B cults ONLY. Style D (Class A) IDC circuits are NOT supported in circuits. any application. SMB500:Optional surface-mount backbox. MDF-300(A)SPECIFICATIONS NOTE: See installation instructions and refer to the SLC lMring Normal operating voltage range: 15 to 32 VDC. Manual,PN 51309. Maximum current draw:6.4 mA(LED on). Architects'/Engineers' Specifications Average operating current:750 pA(LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Specifications of these devices and all FireLite products are available from FireLite. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance:47K Ohms. Temperature range: 32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125'(5.398 cm)deep box. MDF-300(A)AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm)square, 2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A)module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424. • ULC: S2424. • FM Approved. • CSFM:7300-0075:0185. • MEA:72-01-E. Product Line Information NOTE:"A"suffix indicates ULc-listed model. IMMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module,two-wire detectors. DF-52121:E•07/30/2015—Page 3 of 4 Fire Lite®is a registered trademark and LiteSpeed',"and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E RT F E We cannot cover all specific applications or anticipate all requirements. ENCINEEIINC B MAMMIES All specifications are subject to change without notice. • QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473, FAX:(877)699-4105. www.firelite.com Page 4 of 4—DF-52121:E•07/30/2015 df-60379:A1 •E-400 CRF-300(A) Flre•Lrre°ALarms RelayModule by Honeywell Addressable Devices General The CRF-300(A)Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be iir 0. , activated through panel programming,on a select basis. LiteSpeedTM is a communication protocol developed by -u.. �. Fire•Lite Engineering that greatly enhances the speed of com- * •°E° "^•^< munication between analog intelligent devices. Intelligent •, °� devices communicate in a grouped fashion. If one of the ri devices within the group has new information, the panel CPU .� stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. • a Features • Built-in type identification automatically identifies these % p devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral LED "blinks" green each time a communication is CRF-300(A) received from the control panel and turns on in steady red when activated. • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. Specifications • Direct-dial entry of address:01—159 for MS-9600(A)series Normal operating voltage: 15 to 32 VDC. panels,01 —99 on MS-92000DLS(A)and MS-9050UD(A). Maximum SLC current draw: 6.5 mA(LED on). Average operating current: 230 pA direct poll (CLIP mode), Applications 255 pA group poll(LiteSpeed mode)with LED flashing. The CRF-300(A) may be programmed to operate dry contacts EOL resistance: not used. for door holders,Air Handling Unit shutdown,etc.,and to reset Temperature range: 32°F to 120°F(0°C to 49°C). four-wire smoke detector power. Humidity range: 10%to 93%non-condensing. Construction Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x • The face plate is made of off-white heat-resistant plastic. ' 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x Controls include two rotary switches for direct-dial entry of 2.125"(5.398 mm)deep box. • address setting. Relay Contact Ratings • The CRF-300(A)is configured for a single Class B(Style Y) or Class A(Style Z)Notification Appliance Circuit. Maximum Current • The CRF-300(A) provides two Form-C dry contacts that Load Description Application Voltage Rating switch together. Resistive Non-Coded 30 VDC 3.0 A Operation Resistive Coded 30 VDC 2.0 A Each CRF-300(A)uses one of the addresses on a SLC loop. It Resistive Non-Coded 110 VDC 0.9 A responds to regular polls from the control panel and reports its Resistive Non-Coded 125 VAC 0.9 A type and status, including the open/normal/short status of its Notification Appliance Circuit(NAC).The LED blinks with each Inductive(L/R=5ms) Coded 30 VDC 0.5 A poll received.On command,it activates its internal relay. Inductive(L/R=2ms) Coded 30 VDC 1.0 A NOTE:Open/short supervision is suspended with the CRF-300. Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable)will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. df-60379:A1•08/04/09—Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424 • ULC: S2424 • FM approved • CSFM:7300-0075:185 • MEA:72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. : Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual,document 51309. LiteSpeedTM is a trademark and Fire•Lite®Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. 4CEFt-TIFIECIP We cannot cover all specific applications or anticipate all requirements. ENSINEEI1NC R MANIIFACNRIN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—df-60379:A1•08/04/09 kw. SYSTEM ._*VSENSOR' I1.ttt1I1 IIIIIIIII 111111111 r Selectable- I R yaw R Output Horns, Strobes, and Horn Strobes for Wall Applications � � r System Sensor L-Series audible visible notification products are rich with features guaranteed to cut K .�� ,,:. .• f* z installation times and maximize profits with lower current draw and modern aesthetics. .µz Features _ .. • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela • Field-selectable candela settings on wall units: The L-Series line of wall-mount horns,strobes,and horn strobes 15,30,75,95, 110, 135,and 185 include a variety of features that increase their application versatility • Horn rated at 88+dBA at 16 volts while simplifying installation.All devices feature plug-in designs • Rotary switch for horn tone and two volume selections with minimal intrusion into the back box,making installations fast and foolproof while virtually eliminating costly and time-consuming • Mounting plate for all standard and all compact wall units ground faults. • Mounting plate shorting spring checks wiring continuity before device installation To further simplify installation and protect devices from construction • Electrically compatible with legacy SpectrAlert and SpectrAlert damage,the L-Series utilizes a universal mounting plate for all Advance devices models with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Strobes and Horn Strobes listed for wall mounting only Installers can also easily adapt devices to a suit a wide range • Horns listed for wall or ceiling use of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING ® APPROVED I• I LISTED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383.3057072 AVDS865-05•2/22/2018•Page 1 L-Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 17/8-inch back box,4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit'°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,110, 135,and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize Strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 1.91"D(143 mm L x 119 mm W x 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46"W x 1.91"D(133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D(143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25"L x 3.45"W x 1.25"D(133 mm L x 88 mm W x 32 mm D) 1. Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. AVDS865-05•2/22/2018•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non-Temporal High 43 47 54 95 N/A 121 155 Non-Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Wall Horn Strobe,Candela Range(15-185 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1KTemporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on 2-wire horn strobes.Temporal coding must be provided by the NAC.If the NAC voltage is held constant,the horn output remains constantly on. AVDS865-05.2/22/2018•Page 3 L-Series Dimensions 1.91" -,-.-- 3.46" —a 3.46" 11.25 mm 88 mm 31.25' (9.1 88 mm - 48.5 32 mm155' 32 mm cm) I (3S tm) i��g ioeai�i �Ooo°oo°°lioo, UP 09°69°66 5.27" . , °60000poo°o30 5.38' 133.9 mm I 8111 5.27" °°°0°0°6°0°•a. (13.7 cm) O 1. IJII 133.9mmt i/ - ''r''rr�o114� o " l ;6J til - A0548-00 A0547-00 50557-00 Compact Strobe,Horn Strobe Compact Horn Compact Wall Surface Mount Back Box SBBGRL,SBBGWL 4.70" (11.94 cm) _ 1.91" 4.7" __ (4.85 cm) 119 mm 424c 1.25" 32 mm (1220 cm) �6 ,1 C7..›.....,.... (3.18 mm) a (.._..' ) -� (tam) 1i1 ® , 11 - 5.67" "-'.'-�+' 5.67" o°°°o°44.: 5.78' :44' 7-( (14.4 cm) 144 mm °o°o°o°u°nr�- 11 14.68 cm) - L I:s sos°°1 _ 0 ���r44 A0550-00 A0549-00 A0554-01 Strobe,Horn Strobe Horn Wall Surface Mount Back Box SBBRUSBBWL L-Series Ordering Information Model Description Model Description Wall Horn Strobes orns* LP2RL 2-Wire,Horn Strobe,Red HRL* Horn,Red - P2WL 2-Wire,Horn Strobe,White HWL* Horn,White P2GRL 2-Wire,Compact Horn Strobe,Red HGRL* Compact Horn,Red P2GWL 2-Wire,Comp 2 fits act Horn Strobe,White HOWL* Compact Horn,White P2RL-P 2-Wire,Horn Strobe,Red,Plain Accessories P2WL-P 2-Wire,Horn Strobe,White,Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire,Horn Strobe,Red,FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red P4RL 4-Wire,Horn Strobe,Red SBBWL Wall Surface Mount Back Box,White P4WL 4-Wire,Horn Strobe,White BBGRL Compact Wall Surface Mount Back Box,Red Wall Strobes SBBGWL Compact Wall Surface Mount Back Box,White f SRL Strobe,Red SWL Strobe,White SGRL Compact Strobe,Red SGWL Compact Strobe,White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP Strobe,Red,FUEGO • SWL-CLR-ALERT Strobe,White,ALERT Notes: All-P models have a plain housing(no"FIRE"marking on cover). All-SP models have"FUEGO"marking on cover. All-ALERT models have"ALERT"marking on cover. *Horn-only models are listed for wall or ceiling use. *- SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©2018 System Sensor. j SENSOR Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice,visits ensor.com � for current product information,including the latest version of this this data sheet. www.systemsensor.com AVpS865-05.2/22/2018 SYSTEM �$ SENSOR' Outdoor Selectable- Output Output Horns, 5 - Strobes, and Horn Strobes for Wall Applications SPECTRSert SpectrAlertx Advance outdoor audible visible products ` Ila v a IlN mit are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field-selectable candela settings:15, 15/75,30,75,95, 110, 115, 135, 150, 177,and 185 Like the entire SpectrAlert Advance line,outdoor horns,strobes, and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. •• Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock-outs located on the back eliminate the need to drill SIGNALING ( holes for screw-in mounting.Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3A-inch 7300-1653.187(outdoor strobes) LISTED ® MEA 7125-1653 188 morn strobes, knock-outs at the back.A screw-in NPT plug with an 0-ring gasket aS4011(chimes,horn s!robes,horns) APPROVED pp chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653.189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between—40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110, 115, 135,150,177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature —40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 • 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic Strobe Output(cd) Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal • 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 • tSettings 7,8,and 9 are not available on 2-wire horn strobe. AvDSO1201 SpectrAlert Advance Diagrams 4.7" ► 2.5'•'—or /MT MP 5.6" - •� Wali-count Horn Strobes Wall Pvc)We\� a BacB�o�Ox IF � � I:.. 9IrtatesS1111111 -1 I I 69 Ia Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn StrQJ?es P2RK"t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK"t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK"t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: "Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM ®2012 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Product specifications subject to change without notice.Visit systemsensoccom SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS01201•3/12 SYSTEM �$ SENSOR` Indoor Selectable- Output Strobes and .. .- r Horn Strobes for =- Ceiling Applications, g System Sensor L-Series audible visible notification - products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. /#' Features The System Sensor L-Series offers the most versatile and Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry • with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: 15,30,75,95, 115, 150,and 177 strobes include a variety of features that increase their application versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- • Universal mounting plate for ceiling units consuming ground faults. • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING (20 41> CO LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383 AVDS868-02•12/01/2017•Page 3 L-Series Specifications Architect/Engineer Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit""Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95, 115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 • Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9"diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86B-02•12/01/2017•Page 2 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max.Current Draw(mA RMS),Ceiling Horn Strobe,Candela Range(15-177 cd) 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1K Temporal High 111 164 69 94 147 163 184 229 257 3.1K Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 • Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.1K Temporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output(dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868-02•12/01/2017•Page 3 L-Series Dimensions 2.47"(62.7 mm) 1.37"(34.8 mm) = = 6.92"diam. 2.5" 6.83"diam. (175.77 mm) (64 mm) � (173 mm) a /•on+M\ j --1 III i -g000g , _� _ (.. i 41,i 1 1 c .:.•,-„,_,,-„,,„__:-.s.,.:,.) —goo ®g J A0545-00 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box ., B--1-1,711-111 - OAirP" •-• L) ilicNivii, ,„:„.,,,,, .„...,,, Flt_\ 411 4000 /l r ® fi 0 114 47 :1411: (1/ 4;1411"111 %?0:75'72:1'1—‘V OOO t 3= - wa, ‘��- "O;01, - pAdy s 4 � Op ;_ y1b°/ t S >_r 1. A0494-01 A0531-01 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Model Description Ceiling Horn Strobes Ceiling Strobes IPC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White PC4RL 4-Wire,Horn Strobe,Red SCWL-CLR-ALERT Strobe,White,ALERT PC4WL 4-Wire,Horn Strobe,White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White For a ceiling-listed horn-only device,see AVDS865"Indoor Selectable- Output Horns,Strobes,and Horn Strobes for Wall Applications". `) SYSTEM ©2017 System Sensor. A 3825 Ohio Avenue•St.Charles, IL 60174 Product speciticatons subject to change without notice.Visit systemseosohcom �� SENSOR'SOR Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of this data sheet. AVDS868-02•12/01/2017