Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (3)
4. Mee2D2o'-armIr n 9 1,,,,oks.,a �r 4/60Job Name: Tag# . . . ... ... . Submittal Data Sheet FTX36NVJ1 • �/Ri3gN FJEJ• : 3-Ton Wall Mounted Heat Pump System ... ... . . .. .. Cffilei ict Cooling: : "' "' SAQattng SEER 15.9 HSPF 9.2 EER 9.10 COP 2.78 Performance Cooling(Btu/hr) * i ' —_ / Rated(Min/Max) 34,400(10,200/34,400) fr"-r- .�.---i Sensible @ AHRI 22,160 f' .r J#—. J Standard Operating Range 50°F–115°F I i t'I T P D Extended Operating Range* -4°F–115°F J 1 === Rated Cooling Conditions: Indoor:80°F DB/67°F WB Outdoor:95°F DB/75°F WB *Nunne�_ *With field settings and wind baffle Heating(Btu/hr) _, _ - 1:@ 47°Rated(Min/Max) 36,000(10,200/36,000) Complete warranty details available from your local dealer or at 2:@ 17°Rated 22,800 www.daikincomfort.com.Warranty registration not required to 3:@ 5°Max 15,740 receive the 10-Year parts limited warranty for residential or Operating Range 5—65°F commercial installations. 1:Rated Heating Conditions: Indoor:70°F DB/60°F WB Outdoor:47°F DB/43°F WB 2:Rated Heating Conditions: Indoor:70°F DB/60°F WB Indoor Specifications Outdoor:17°F DB/15°F WB 3:Rated Heating Conditions: Indoor:70°F DB/60°F WB Cooling Heating Outdoor:5°F DB/5°F WB H M H M Airflow Rate(cfm) 915 742 960 791 Electrical L SL L SI 208/60/1 230/60/1 572 512 629 544 System MCA 19.8 19.8 Sound(dBA) System MFA 20 20 H/M/L/SL 54/47/40/37 53/46/38/35 Compressor RLA 18.25 18.25 Dimensions(H x W x D)(in) 13-3/8 x 47-1/4 x 10-3/16 Outdoor fan motor FLA .83 .83 Weight(Lbs) 38 Outdoor fan motor W 123 123 Indoor fan motor FLA .37 .37 Outdoor Specifications Indoor fan motor W 64 64 Compressor Hermetically Sealed Swing Type MFA: Max.fuse amps MCA:Min.circuit amps(A)FLA:Full load amps(A) RLA:Rated load amps(A) W:Fan motor rated output(W) Refrigerant R-410A Piping Refrigerant Oil PVE(FVC50K) Liquid(in) 1/4 Cooling Heating Gas(in) 5/8 Airflow Rate(cfm) Drain(in) 5/8 H 2,811 H 2,352 Max.Interunit Piping Length(ft) 98.4 Sound Power Level(dBA) 59 Max.Interunit Height Difference(ft) 65.625 Dimensions(H x W x D)(in) 28-15/16 x 34-1/4 x 12-5/8 Chargeless(ft) 32.8 Weight(Lbs) 133 Additional Charge of Refrigerant(oz/ft) .32 Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date:July 2017 Page 1 of 4 e"' 4 Z ' ' - .4. 0 0 L N LIIII 3 a, O d N LC 11111111 0 v Sv, LE .0 4 C ik THE MARK(->)SHOWS PIPING DIRECTION 13 47-1/4(1200mm) j/ // ������������������������1 (0 f REAR f / '4111 LO VI 0 0 z w .@ LEFT RIGHT ¢ a U } = Oa v } LL O - 1,,_ } = 111 = c O f r i i - / L_I ( o00 / C. a o b, z• co 0 o �^ u o 1-15/16(50mm)MIN 1 15/16(50mm)MIN • o E47 1/4(1200mm) (SPACE FOR (SPACE FOR v a m S.' "c c 42-11/16(1085mm) Eco MAINTENANCE) REQUIRED SPACE MAINTENANCE) v -o5 CD .. 1-3/8(35.5mm) _ - 2-5/16(58.5mm) c E .5 o -at ! _(INCLUDING MOUNTINGPLATE) • .,a0.— v) (a o E 10 1/4(261mm) _, Y N o <j'PLATE N Co v 1 E D E co co 000 Ev = CO CO a n � E 0 o NAME cD J � o WALL HOLE FOR EMBEDDED PIPING WALL HOLE E r•• d3P10(680mm)HOLE 3-1/8(080mm)HOLE -et TERMINAL E• 79/16(6' fit•• 3-1/2(89mm) BLOCK / J o • • WITH GROUND a •••• ST/;fyC�99d LOCATIONS OF WALL HOLES TERMINAL WIRELESS REMOTE CONTROLLER E E. 3 ••••. ••• (ARC466A37) 0 • •• •• • • c 0•••• n ••. • • C •• •• Ou I-, ••• •• • • O .--I • •S . • o N • •• >••• • • • .0 • •• •• H N Z••• ` (6 (15 . • In o •••• Y = •••• U ._ m•••• •• • c :° Y t0 O 3 a 3 ii......_Z .6-. O O r m 3 N ••• - d • •••• •••• •• • c •••• ro '... ::••=1-g. 9/16(14) Y 34-1/4(870) 2-3/4(70) v •••• 1/4(7) 12-5/8(32(1)•• •r-3/16(30) OUTDOOR AIR THERMISTOR c BRAND NAME PLATE ELECTRIC WIRE INTAKE c Cill i Pr.Ij"`Viii " •• 1 1 ! /� I �—•• :rim • I P V © , MANUFACTURER'S LABEL Ln c V 3/4(19 ro • • _ :— 4 r4 a n ra II ���. 1111 1 c v / o Si .,. .� . l Y t,4{ii Ill I ii,i p bD 4-HOLES FOR FOUNDATION BOLTS 9/16(14.5 718(23) .� o m (M8 OR M10) 23-5/8(600) 1 4-15/16(125) 13-5/8(346) I 7/16(11) _ n m c (INSTALLATION LEG o z-.z -0 3 V c rn •• 14-1/2(368) n $ co 0 g - C13 7 c` 0 (--.....-4 O III WALL HEIGHT ON AIR OUTLET SIDE v v v• -o 4—+ 1 ! VINIMUM SPACE FOR AIR PASSAGE m Y c 2-GROUND TERMINALS =LESS THAN 47-114(1200) .. .. 0000 0 5 ; u ��. ro 4111 c! 'I � LIQUID 20-11/16 525) / E g', c .a., STOP VALVE %iiiiiiiiiii�iiiri/riiiiiiii Q (D •_ a (/114(Q6.4)CUT) DRAIN OUTLET 4 Y Y c r• 0 GAS (I.D 05/S(p15.9)HOSE FOR i z o STOP VALVE CONNECTION WITH DRAIN JOINT) o _ I .5 Y ® (05(8(15.9)CUT) c i ll m $ o p ti o ! 1-15/16(50) 'r co c� 1.15116(50) I ` v 1-15/16 50) > Q) SERVICE - PORT N m o E 4 E IIIIco I = i cr:: i c 0 D _ o 'O UNIT:inch(mm) 2 No > 6-13/16(173) IN CASE OF REMOVING u STOP VALVE COVER AND ▪ 3 TERMINAL STRIP COVER N v IL zo c (0 i O CO 0v,a O Ct H in Opti#�� I iAc��R �ti�• • •• �/K//VI • • •• • •• • • •••• • • • • •• • •• • • • •• • • •• •• • • ••• •••• •• •• •• • • • • ••• i •• • • •• • • • • ••• • • • • • Indoor Unit ••• • • • •—•—• Included • Pi't•Numblsr ••• ••• • Description BRP072A43 Wireless Interface Adapter otr9 12-0Q$ •• •;• •;• Wired Remote Controller LRCw9(LA:1518: ••: • a Wired Remote Controller Cord-3m • S . • • • • DIVC'R-13RCW9011'10 ••• • Remote Controller Cable,Plenum Rated, 10 ft DACA-BRCW901P25 Remote Controller Cable,Plenum Rated,25 ft DACA-TS1-1 Daikin ENVi Intelligent Thermostat Kit DACA-CP1-1 Inline Condensate Pump(Fits inside all Daikin wall&floor mount units) DACA-CP4-1 External Condensate Pump KRP928BB2S Interface Adaptor for DIII-NET Outdoor Unit Included Part Number Description KEH063A4E Drain Pan Heater(RX) KPW063A4 Air Adjustment Grille(RX&RK) KKG063A42 Back protection wire net Daikin North America LLC 5151 San Felipe,Suite 500 Houston,TX 77056 (Daikin's products are subject to continuous improvements.Daikin reserves the right to modify product design,specifications and information in this data sheet without notice and without incurring any obligations) Submittal Creation Date:July 2017 Page 4 of 4 • •• •• •1, • • • • •• • • • • • • • • • • • a • • • • •• •• • • • • •• •• ••• •• •• ••• • • •• •• • • • • • • 4 'b reez Q I E LTII p Signature 1�1 'I• . '1 1.� . 1 Ej� IG80 • • • • • ••. •(80 CFM) • • • • • • ••• 0 • _SAM._ 4"Duct(Standard): MI 111/1 80 CFM/<0.3 Sones @ 0.1 SP,8.7 Watts C43) us CERTIFIED 79 CFM/0.5 Sones @ 0.25 SP,14.0 Watts ••. ••• • • 41. 1 1 1 . 111111 Description TYPICAL SPECdFICQTI�N Low noise ceiling mount ventilating fan for continuous Ventilation fan shall be Delta Breez model IG80; ENERGY running.Fan has been awarded ENERGY STAR'. It is HVI,UL, STAR qualified with Brushless DC Motor engineered to run and cUL certified,and can be used to comply with ASHRAE continuously for a minimum 70,000 hours; airflow rating of 62.2(local and whole building continuous and intermittent 80 CFM and loudness rating of<0.3 Sones at 0.1 static operation). Meets CA Title 24 requirements. pressure as certified by the Home Ventilating Institute(HVI); power consumption of 8.7 Watts with efficiency rating of DC Motor/Blower 9.7 CFM/Watt; fan will feature LED indicator running light, • Power rating of 120 volts/60Hz motor lock protection and self-compensating motor speed • DC brushless motor engineered to run continuously for intended airflow when static pressure is encountered. • Motor equipped with thermal cutoff fuse UL and cUL listed for tub/shower enclosure when used • Removable with permanently lubricated plug-in motor with GFCI-protected branch circuit wiring. • Built-in soft start function to increase bearings'life • Automatically powers off when impeller is locked abnormally • Self-compensating motor speed for intended airflow when static pressure is encountered .00 Housing I! • Galvanized steel body • Detachable 4"diameter metal duct adapter ✓ � o /0./ag , „ • Built-in backdraft damper �/, _ ' \7/4 p �'' i►� / 1N- „ • lr ( . Easy installation with expandable extension bracket I+ �' Grille • Attractive design using ABS material 9�„ i gsla • Attaches directly to housing with torsion springs \',,--- o LED Indicator - • Turn the power switch on/off to operate on/off. LED indicator will be green when power is on -.� Warranty /2.4„�/ ;2-'1'• 3-Year limited warranty Fan Curve 0.90 BreezSignature SIG80 4"Duct(Standard) 0.80 Static Pressure(inches w.g.) 0.1 0.25 I 0.70 Air Flow(CFM) 80 79 G 0.60 0.50soft Sones <0.3 0.5 z Power Consumption(Watts) 8.7 14.0 7 0.40 40ft ' 0.30 301, ^ Energy Efficiency(CFM/Watt) 9.7 6.3 0.25 oft Current(Amps) 0.30 Max 020 Power Rating(V/Hz) 120/60 0.10 fj_ 0 0 30.0 60.0 90.0 120.0 150.0 Air Flow(CFM) -01.- Model ►Model Quantity Comments Project: Location: Architect: Engineer: Contractor: _ Submitted by: Date: 46101 Fremont Blvd., Fremont,CA 94538(tel 1.888.979.9889 I www.deltabreez.com