Loading...
Report (79) al 5 ..o1 Z - oov 3 1 Moffet Energy Modeling CCB#223372 Phone: 916-342-0742 tylermoffet@moffetenergymodeling.com Blower Door Test Affidavit Permit#: Builder: Polygon I`-11[00 Site Address: Eastridge Lot 123: 2•SW Gold coast Terrace,Tigard, OR 97224 Conditioned Floor Area (sq.ft.): 1390 Source: Calculated from plans Calculated Building Volume (cubic feet): 13300 TEST RESULTS: 825 CFM @ 50 Pa ACH @ 50 Pa = {(CFM x 60)-Volume}: 3.72 Ring: Open OA B Minneapolis Blower Door and DG 700 Manometer I certify that these building leakage rates are accurate and determined using standard BPI testing protocol. Company Name: Moffet Energy Modeling Technician: Tyler Moffet Technician Signature: Date: 1/13/2020 Oregon Residential Specialty Code R318.2 MOISTURE CONTENT ACKNOWLEDGEMENT FORM am the general contractor or the Owner-builder at the following address: Site Address: 1 Lk 2 d �\--) City -� Permit 4: Subdivision/Lot#: \3-3 and/or Map and Tax Lot#: To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and OAR 918-480-0144,I am notifying the building official that I am aware of the moisture content Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement. [Section R318.2 is provided for reference]. 8318.2 Moisture Content: Prior to the installation of interior finishes,the building official RhRtl be notified in writing by the general contractor that all moisture-sensitive wood framing members used in construction have a moisture content of not more than 19 percent by dry weight of dry framing members. Si wsy, tt ' / / Date: f amt 9-C,:` • or Owner-Builder l:\Build atTorm1 ES-MoistureSensitiveWood.doc 09125108 Oregon Residential Specialty Code R408.1 MOISTURE BARRIER ACKNOWLEDGEMENT FORM , am the general contractor or the owner-builder at the following address: Site Address: 1 Lk\lQ o C)L. Lc.)A--S-C City: Permit#: lc - OCDCD 3 k Subdivision/Lot#: 1 and/or Map and Tax Lot#: To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1 Ventilation.I am notifying the building official that I have installed the Moisture Barrier as per Requirement in ORSC Section 408.1 and have taken the following steps to meet this code requirement: [The ground surface of the under-floor space is covered with 6-mit black polyethylene sheeting with Rioints lapped 12"at seams and 1 ding up the foundation walls 12". t Signature: t _ '' Date: 1 /,'�3 �20 • , . , or Owner-Builder I:BBuiidrniffom\RES-Mo stureBarr er.doc 09/13/2016 Oregon Residential Specialty Code N1107.2 HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS Permit No.: 1')% A IN C^CO3\ Jurisdiction: `t� Site Address: 1 LI 1(i'o e nPc S G' Subdivision/Lot#: and/or Map and Tax.Lot#: By my si ature below, I certify that a minimum of fifty(50)percent of the permanently installed lighting fixtures in the above mentioned building have been installed with compact or linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt. (Oregon Residential Specialty Code N1107.2)' ( Date: /X3/Pz D t AS,,_•$tractor/Au or zed Agent Print Name: '©RSC Section N11O71.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that has a minimum efficacy of 40 lumens per input watt. Screw-in compact fluorescent lamps comply with this requirement The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per input watt. 1:1Bui dingWonrs'RES-HighEf>cimcyLightingdoc 07/01/08