Report (96) ) 1 ST Loll _ (7O 33
Moffet Energy Modeling
CCB#223372
Phone: 916-342-0742
tylermoffet@moffetenergymodeling.com
Blower Door Test Affidavit
Permit#: Builder: Polygon
Site Address: Eastridge Lot 124: 14140 SW Gold Coast Terrace,Tigard, OR 97224
Conditioned Floor Area (sq.ft.): 1390
Source: Calculated from plans Calculated Building Volume (cubic feet): 13300
TEST RESULTS: 715 CFM @ 50 Pa
ACH @ 50 Pa = {(CFM x 60)-Volume): 3.23
Ring: Open A O
Minneapolis Blower Door and DG 700 Manometer
I certify that these building leakage rates are accurate and determined using standard BPI testing
protocol.
Company Name: Moffet Energy Modeling Technician: Tyler Moffet
Technician Signature: 7
ye 101/4 Date: 1/15/2020
Oregon Residential Specialty. Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
, , am the general contractor or the owner-builder
at the following address:
Site Address:
1k-k CD S --D Pc-ST"
City
Permit#:
\ k
Subdivision/Lot#:
4-L-i
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Si .tu*:
. 41, De i / r).-3/ 0
e L , or Owner-Builder
lAiNiicimeTarva\RES-MoistureSaisitivcWood,doc o9r25/os
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
, am the general contractor or the owner-builder
at the following address:
Site Address: 1Ll 1 Lkv
W G--1C> rC)Fg-S.7 L _
City: ` 1
Permit#: 1(4-c 3,21_
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential. Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
ErThe ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
E,. 1 ints lapped 12"at seams and
[T f ctending up the foundation walls 12".
r`
Signature \. Date: 1 l X23/aC)
or Owner-Builder
I\BuiIdm cxm\RES-MoistweBariierdoc 09/13/2016
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.: )�,. t�_OC�3 a- Jurisdiction: i—
Site Address:
tt.� `to &k-• Gc. sem" Z
Subdivision/Lot#:
and/or
Map and Tax Lot#:
By my si r. ture below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature D
-- - - Date; 11 a3
/ry •r :.r+ ttactor/Au • Agent ....._..
Print Name:
`ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt Screw-in compact fluorescent lamps comply with this
requirement.
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
t:\Bu tdingiFcnms\RFS-HighEfficimcyLighcmg.doc 07/01/0$