Loading...
Plans 4 Project Data JFFICE COPY Sheet Index x sikuC T UR 5���tp PRaf7ss< Ted Clark A.01 Project Information A.05 Elevation and Details ��� �Gt AFF Owner 13890 SW 114th Ave LIABILITY i �� x'183 E� Tigard, OR 97223 TheCity of Tigard d ® A.02 Site Plan E.01 Single Line Diagram f� Ir �►ees shall notb L )1/ I ',a Project Address 13890 SW 114th Ave OR GON Tigard, OR 97223 ittpohtibie for discrepancies A.03 Roof Plan E.02 Electrical Notes hoc �g� whiiah may appear herein. dF h 19, ���, Project No. 19-70-7034 A.04 Floor Plans E.03 Label Sheet �' R. G� Project Type Solar Photvoltaic CITY OF TIGARD EXPIRES= 6-3o-21 - Residential REVIEWED FOR ODE COMPLIANCE Vicinity Map Approved:rP [ Contractor Neil Kelly Company OTC: [ ] 804 N Alberta St Permit#: 'MS-Vac/9-- Ct459 Portland, OR 97217 Address: 13$9 0 SW I lya`"Avit-i Contact: Zane Goff Suite #: Izivi 1� z Phone: 503.335.9218 B): HIS Date: i 1M Lu Applicable Codes 2014 Oregon Structural Specialty Code (Section 3111) D z 2010 Oregon Solar Installation Specialty Code = m 2017 Oregon Electrical Specialty Code m / Project Notes SW VIEWMONT LN / / / PV System 8.45kW-Grid Tied Photovoltaic System / (26)x Q.CELLS Q.Peak Duo-G5.2 325W PV Modules w/Solar Edge Location of / Descritiption P320 DC Optimizers proposed Solar • SW GAARDE ST (1) Solaredge 7600H-US DC to AC power inverter PV System Q.CELLS Q.Peak Duo-G5.2 325W PV Module Module Dimensions: (W)39-1/16"x(L)66.3"x (H)1 -3/8" Type & Module Weight: 39.7 lbs Combined weight of modules and racking <4.5 PSF Specifications VALIDITY OF PERMIT Roof & Composite Shingle Roof Age: <10 years Layers: 1 THE ISSUANCE OFA PERMIT Structural Roof Framing: 2x6 DF#2 @ 24" OC Approved plans 120/240v 1 Phase-3w Service BASED ON CONSTRUCTION Roof Tilt: 21° Array Azimuth: 87° shat] be on job site. Electrical Panel make/model: Square D QOB 30X200-3 DOCUMENTS AND OTHER Specifications Area of Roof: 2896.7sq ft Information Main Breaker rating: 200A DATA SHALL NOT PREVENT Area of PV Array: 475.3sq ft Bus Bar rating: 200A THE CODE OFFICIAL FROM Array= 16.4% of roof area REQUIRING THE CORRECTION 36" Pathway not required per OSISC 3111.4.8.1 Exception 1.1 OF ERRORS. ORSC 105.4 CONFIDENTIAL THE t Neil Kelly Company INFORMATION CONTAINED IN Ted Clark REVISIONS OR CCB# 1663 THIS DOCUMENT IS THE SOLE 13890 SW 114th Ave N— °'a PROPERTY E NEIL KELLY. MM/DD/YY REMARKS .. I . 804 N Alberta St ANY REPRODUCTION USE OR 1 - / -/-- ... O .q4. DISCLOSURE OF THIS Tigard, OR 97223 2 , ti i { ` , Portland, OR 97217 INFORMATION IS PROHIBITED " k:,r.. A., WA L&I# WITHOUT THE WRITTEN 3 --/--,-- TEL: 503.288.7461 NEILKC118702 CONSENT OF NEIL KELLY. 4 /-- ©2018NEILKELLYCO. Drawing: Project Information Date: November 4, 2019 Q 5 / i (e) Utility Meter on exterior .„, . SYSTEM DETAILS (n) 60AAC Lockable Disconnect and Rapid MODULE Q.CELLS Q.Peak Duo-G5.2 325W \ \ \ / i Shutdown Initiation switch `\1 / \ INVERTER Solaredge 7600H-US 'N \ \ " ,/,i ,' located adjacent to meter �',G <�\\ SYSTEM SIZE 8.45kw o \ f7._-— 0 — < , \ L\ \\ \ \ ROOF TILT 21° *I= _ O _ - Property line ± ,a ARRAY ORIENTAT16N 87° --> (---- _ I� � II L O _ , c I ( \ --- �J I / 1 1\ \.,,\\ 'i\C `� <\ 1.1111111111 :\:::::1/014k\\ / � -o�j , a IIS_—I�+ Imm. o \ m. X183 6P;1'f I4� IORM ' \\ / F 0/.c 1°' � F h 19, # : (e) 200A electrical panel ; - _ 0 at GARAGE i o G EXPIRES: 6-30-21 100_ (n) Solaredge 7600H-US \ \1L:/,� i,\ Inverter �` - IN7 rn 1- CD ,m,, i—. . , , II ,\\ , 1 . L. Ism— _ _ , , • a„i� _ . _ _ _ _ 1 .:_._ • ,..._ •. < /// \\ � \� ✓ I ! %�— Suneye Capture N. • Location #8 \ II TSRF 75% (n) 26x Q.CELLS • \ \ �\ ;. ,'� Q.Peak Duo-G5.2 325W j� .�I\; 1\/ �/� 'ill�I\; \/ ��� o PVModules I �� I - — • �\ �� Property line J `-- -� A- `-- �'\! ✓ - Scale: 1” = 10' -0" ' "I•I/1 /�N ---\, �"/I/1 I--N i I I i I I --_—_—_\ CONFIDENTIAL:THE Ted Clark REVISIONS /�� Neil Kelly CompanyCONTAINED THIS DOCUMENTIISHE SOLE (� c :NrE: 804 N Alberta St Portland, OR 97217 OR CCB# 1663 PROPERTY OF NEIL KELLY. 13890 SW 114th Ave MM/DD/YY REMARKS ANY REPRODUCTION,USE,OR --/__/__ DISCLOSURE OF THIS Tigard, OR 97223 2 __/__/-- O INFORMATION IS PROHIBITED WITHOUT THE WRITTEN 1 TEL: 503.288.7461 NEILKC118702 CONSENT OF NEIL KELLY. Drawing: 4 Site Plan Date: November 4, 2019 / / Q ©2018 NEIL KELLY CO. 5 / / .. (n) 26x Q.CELLS Q.Peak - Z_0' Duo-G5.2 325W 7-47 7 (e) chimney II I ,-. / I I (n) ironridge XR10 rail max cantilever 2'10" �_��.._.. �._.. .p.... ..®._ ® _... .�.._ per manufacturer \ j' I r (n) ironridge flashfoot2 _®_. .._..®._.._.®..._ .0._ ._•. _..•@ _0_. solar stanchion (e) 2x6 DF rafter 48" OC max -0-.•...®. _-0-•• -••@•-•._.® ••-•• ; ..[.. .._ .•,§1. @24" OCtyp • 3-••-••4)• -{®}.. ...4§1._.._..._..g3._.. .CO-.._ .-1§'.t • q (e) 200AAC load center& I (n) point of interconnection (e) 2x6 ridgeboard 'C•UCTIM (n) Solaredge 7600H-US inverter I .\lcR0 PRaf£ss,< I1834•r CP Y11101 j \ \ I \ -O OR GON �\ X40 h 19, �e',•:?3, R. GO I \\ EXP!RES' 6-30-21 1 (e) meterbase & utility service entrance (n) 60AAC disconnect and rapid • o N shutdown switch AW ' V Scale 3/16" = 1'-0" CONFIDENTIAL THE Ted Clark REVISIONS INFORMATION CONTAINED IN Neil Kelly Company THIS DOCUMENT IS THE SOLE 13890 SW 114th Ave CO 804 N Alberta St OR CCB# 1663 PROPERTY OF MM/DD/YY REMARKS jç ANY REPRODUCTION,USE,OR 1 O Portland OR 97217 DISCLOSURE OF THIS Tigard, OR 97223 2 ,_ , INFORMATION IS PROHIBITED WA L&I# WITHOUT THE WRITTEN 3 / / TEL: 503.288.7461 NEILKCI18702 CONSENT DFNEIL KELLY Drawing: Enlarged Roof Plan Date: November 4 2019 5 --%-/ .. Q ©2018 NEIL KELLY CO. (e)2x6 ridge beam © 15'6" © ---/— 2x4 ridge bracing @ 48"OC (e)2x6 DF Rafter •04 , 04 (e)2x8 DF ceiling @ 24"0C joist @ 16"OC ---- 8'-8" -----p----- 9'-3" -- - ---- 10'-0" , I co 8'-0" --- , I 400411 I - } 4x14" raised beam . rigill , 1 `I (e)2x4 purlin (e)2x4 stud wall bracing @ 24"OC / 16'-0" / /%'\V �- io M - i co (NI Lo 4--- 7'-11" ---•# - 5'-2" - 4'-8" ¢' 16'-9" 2. Roof Section - Flat Ceiling Scale 1/8" = 1'-0" 17'-8" I o - 9'-0" ---- ---- 9'-0" ----k 5'-0" 12'-6" /-- I-. I T T (e)2x4 purlin , „ „ bracing @ 24 "OC —/f �� 9'-6" �� 13'-6" ,j4 I �� I 21'-0" -f 32'-6" - , /-- 6'-4" -- (e)4x14 DF (e)2x6 ceiling joist@ 16"OC raised beam ,e?,0C Tut, 5��0.1) PRO/- .< I �GINFF % I ,1 q Xlik 183'6P 4 11'-1" ,IV( 24'-1" 1 i) -O 4, V E.• co t ~ °'� �, d111111113. Roof Section Vaulted Ceiling 1. 1st Floor Plan ���FR R. GO' _ Scale 1/8" = 1'-0" lir Scale 1/8 = 1 0 EXPIRES: 6-30-21 CONFIDENTIAL:THE Ted Clark REVISIONS Neil Kelly INFORMATION CONTAINED IN Company THIS DOCUMENT IS THE SOLE 13890 SW 114th Ave MM/DD/YY REMARKS O 804 N Alberta St OR CCB# 1663 PROPEDISCLOSURE TY URE OF IL KELLY. /- / ANY REPRODUCTION,USE,OR 1 Portland OR 97217 FOIS THIS Tigard, OR 97223 2 INFORMATION / IS PROHIBITED --"NliK WA L&I# WITHOUT THE WRITTEN 3 --, -, - . TEL: 503.288.7461 NEILKCI18702 CONSENT OF NEIL KELLY. ©20,8NEIL KELLY CD. Drawing: Floor Plan Date: November 4, 2019 5. --/ / Q ,S�UC T VRAl NS��D PROFtSs, rail configuration typical Ironridge Flashfoot 2 ,.., ,�GtN£F,A q 4 clamps per module. g a, 1836P. l rails and attachments J 1 I i per OSISC and manufacturer ,t i installation requirements - -O •'E.• C 7 FQ�. h 19, D,4, R. G �' EXPIRES= 6-30-21 -- Uy A06 1 N ili 1 IronRidge XR10 / - Rail __--_� 71,__ (e) roofing system (e) 2x4 rafter 2. Rail Connection Detail Scale: 1/4"= 1'-0" (n)Q.CELLS Q.Peak Duo-G5.2 . (n)Ironridge XR100 325W / 7 continuous rail ./� and UFO clamp 'jam i Ironridge FF2 Standoff / 32" OC Max Spacing -; ' S , / �' i (e) roof assembly �Z (n)lag screw per Z manufacturer / 5/16" x 4 1/2" (e) 2x4 rafter 3. Rafter Connection Detail Scale: 3/4" = 1'-0" CONFIDENTIAL THE Ted Clark Neil Kelly Company INFO MATIIONNTON CONTAIN DIN OEEVISIONS 804 N Alberta St OR CCB# 1663 THIDOTYOFN IIL 13890 AlSW 114th Ave MM/DD/YY REMARKS µr ANY REPRODUCTION,USE,OR ______ ... Portland OR 97217 DISCLOSURE OF THIS 2 / INFORMATION IS PROHIBITED Tigard, OR 97223 1 WA L&I# WITHOUT THE WRITTEN 3 __/__/__ O TEL: 503.288.7461 NEILKCI18702 CONSENT OF NEIL KELLY. ©20,SNEIL KELLY CO. Drawing: Section and Details Date: November 4, 2019 5 -- - - Q 3/4" EMT Conduit 4 -#10 PV Wire Conductors 1 -#10 THWN-2 EGC DC DC DC DC DC DC DC DC 1 2 12 13 3/4" EMT Conduit 1 1 1 2-#8 THWN-2 Conductors 1-#8 TWHN-2 Neutral \ 1-#10 TWHN-2 EGC r I \ K DC \ i/ \ \ AC • Dc Dc Dc Dc \ DC DC DC DC \ — — — — — — 1 2 12 13 -U 1 1 1 1 L _ Solaredge 7600H-US Inverter with integrated DC Disconnect. Inverter is functionally grounded, #6Cu Bonding across rails rapid shutdown compliant with Bonding of modules, optimizers and racking attachments integral anti-islanding protection (26) Hanwha Q.Peak Duo G-5.2 325W PV Modules through IronRidge mechanical attachments of array features. and (26) Solaredge P370 Power Optimizers. 1 Optimizer per module. Optimizers connected in series New Net Meter Zoog 1P Provided by Utility in existing meter base SYSTEM OVERVIEW ,oA —•'. 2P System Size (DC@STC) 8.45kW No of Modules in System 26 I I AC Lockable Disconnect and Module Wattage 325W I Existing 200A/240V Hanwha Q.Peak Duo G-5.2 Distribution Panel Rapid Shutdown initiation switch Module Make and Model — Located in Garage Located within 10' of utility meter 325W Inverter Make and Model Solaredge 7600H-US Existing Building grounding electrode CONFIDENTIAL:THE Ted ClarkREVISIONS I 1--1Neil Kelly Company IN THE 1 3890 SW 114th AveMM/DD/YY REMARKS 804 N Alberta St OR CCB# 1663 PROPERTY OF NEIL KELLY ANY REPRODUCTION,USE,OR 1 �� Portland OR 97217 ANY REPRODUCO IS PROHIBITED WA L&I# WITHOUT THE WRITTEN 3 / / TEL: 503.288.7461 NEILKCI18702 CONSENT OF NEIL KELLY ______ ©2018NEIL KELLY CO. Drawing: Single Line Diagram Date: November 1 , 2019 5 / / W PV MODULE RATINGS @ STC DC SOURCE CIRCUIT DC SOURCE CONDUIT SIZING MODULE MANUFACTURER HANWHA MAX PV STRING CURRENT - STRING #1 15A MODULE MODEL#: Q.PEAK DUO-G5 325 MAX PV STRING VOLTAGE - STRING #1 400V WIRE/TYPE SIZE QTY RATED MAX POWER OUTPUT 325W CONDUCTOR QUANTITY - STRING #1 2 CONDUCTORS- PV WIRE 10 2 OPEN-CIRCUIT VOLTAGE (Voc) 40.4V MAX PV STRING CURRENT - STRING #2 15A STRING#1 OPERATING VOLTAGE (Vmp) 33.7V MAX PV STRING VOLTAGE - STRING #2 400V CONDUCTORS- PV WIRE 10 2 SHORT-CIRCUIT CURRENT (Isc) 10.14A CONDUCTOR QUANTITY - STRING #2 2 STRING#2 OPERATING CURRENT (Imp) 9.66A SOURCE CIRCUIT LENGTH (IN FEET) 80 GROUND THWN-2 10 1 MINIMUM EGC 10NA SERIES FUSE RATING 20A NUMBER OF CONDUCTORS IN CONDUIT 4 - CONDUIT EMT 3/4" - Voc CORRECTION FACTOR (%/deg C) -0.28% PV WIRE CONDUCTOR SIZE 10AWG Vmp/Pmp CORRECTION FACTOR -0.37% CONDUCTOR RESISTANCE 1.290 VOLTAGE DROP 0.77% TEMPERATURE CORRECTIONS AC OUTPUT CONDUIT SIZING DC OPTIMIZER RATINGS CONDUCTOR AMPACITY 40A ESIZE QTY MANUFACTURER SOLAREDGE ADJUSTED FOR TEMP @ ROOFTOP 30.4A CONDUCTORS THWWIRE/TYPN-2 8 2 MODEL P370 CONDUIT FILL ADJUSTMENT 24.32A RATED INPUT POWER 370W NEUTRAL THWN-2 8 1 CONNECTION TYPE SINGLE / SERIES GROUND BARE 10 1 MIN MPPT VOLTAGE 8V AC OUTPUT CIRCUIT CALCS MINIMUM EGC - 10 NA MAX MPPT VOLTAGE 60V INVERTER MAX AC CURRENT 40A CONDUIT EMT 3/4" NA MAX SHORT CIRCUIT CURRENT 11A INVERTER OUTPUT VOLTAGE 240V CEC EFFICIENCY 98.80% ___ OUTPUT CIRCUIT LENGTH (IN FEET) 25 MAX OUTPUT CURRENT 15A NUMBER OF CONDUCTORS IN CONDUIT 2 MAX OUTPUT VOLTAGE 60V CONDUCTOR SIZE 8AWG MINIMUM FOR OCPD 8AWG CONDUCTOR RESISTANCE 0.809 INVERTER RATINGS VOLTAGE DROP 0.67% MANUFACTURER SOLAREDGE __ TEMPERATURE CORRECTIONS - MODEL SolarEdge SE7600H- CONDUCTOR AMPACITY 55A US@240 ADJUSTED FOR TEMP @ ROOFTOP 50.05A RATED AC VOLTAGE 240V CONDUIT FILL ADJUSTMENT 50.05A CEC WEIGHTED EFFICIENCY 99.0% MAX AC POWER OUTPUT 7600W MAX DC VOLTAGE 480V MAX DC CURRENT 20A MAX DC INPUT POWER (STC) 1180W INTERCONNECTION AT LOAD CENTER PER GENERAL NOTES MAX MPPT INPUT VOLTAGE 400V NEC 705.12 MAX AC CURRENT 32A OPTIMIZER MODEL P370 MAIN PANEL BUSBAR RATING 200A (1) SYSTEM SHALL COMPLY WITH NATIONAL ELECTRICAL CODE (NEC) (2) SYSTEM SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERAL REQUIREMENTS PANEL MAIN OCPD RATING 200A (3) ALL COMPONENTS SHALL BE GROUNDED PER NEC REQUIREMENTS ASHRAE WEATHER DATA: INVERTER MAX AC RATED CURRENT 31.25A (4) EQUIPMENTALTYPE PV SHALL E LISTED PER NEC (5) TYPE PVVWIRE TO BE USED FOR ALL OUTDOOR WIRING SITE ZIP CODE 97218 PV SYSTEM OCPD RATING 40A (6) THE INVERTER IS EQUIPPED WITH ANTI-ISLANDING PROTECTION PER UL 1741 WEATHER PORTLAND INTL REQUIREMENTS INTENDED TO PREVENT OPERATION OF THE PV EQUIPMENT WHEN THE STATION AIRPORT ALLOWABLE BACKFEED PER NEC 40A UTILITY GRID IS NON OPERATIONAL LOWEST705.12(B)(3)(b) (7) ALL ELECTRICAL COMPONENTS SHALL BE NEW, LISTED FOR THEIR INTENDED PURPOSE, EXPECTED TEMP -6.0°C AND INSTALLED ACCORDING TO FEDERAL AND LOCAL CODES AND MANUFACTURER'S INSTRUCTIONS AVERAGE36.0°C BACKFEED CIRCUIT BREAKER TO BE (8) PERMISSION TO OPERATE THIS SYSTEM IS NOT AUTHORIZED UNTIL FINAL INSPECTIONS HOTTEST TEMP READILY ACCESSIBLE ARE OBTAINED FROM THE LOCAL AUTHORITY HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER CONFIDENTIAL:THE Ted Clark Neil Kelly Company INFORMATION IN REVISIONS CV A-K 804 N Alberta St OR CCB# 1663 THIS PROPERTY OFNEIL NT ISTHEKELLY . 13890 SW 114th Ave MM/DD/YY REMARKS ANY REPRODUCTION,USE,OR 1 /- / O Portland, DISCLO OR 97217 WITHOUT THE RE OF ITT Tigard, OR 97223 z __/__/__ HIS INFORMATION IS PROHIBITED WA L&I# WITHOUT THE WRITTEN 3 _-/--/- TEL: 503.288.7461 NEILKCI18702 CONSENT OF NEIL KELLY. ©2t)18NEIL KELLY CO. Drawing: Electrical Notes Date: November 1 , 2019 4 --/--/-- LU LABELS TO BE PERMANETLY AFFIXED IN CLEAR AND VISIBLE LOCATIONS IN ACCORDANCE WITH THE NEC. a APID STDOW LABELS SHALL BE DURABLE AND SUFFICIENT TO PHOTOVOL 'IC POWER SOURCE SWITCH FOR WITHSTAND EXPOSED CONDITIONS. SOLAR Pi SYSTEM LABELS EXCEPT AS NOTED SHALL BE RED MAX SYSTEM VOLTAGE: 480V BACKGROUND. LETTERING TO BE ALL CAPITAL AND MAX CIRCUIT CURRENT: 15A WHITE COLOR. MAX RATED OUTPUT CURRENT OF Label to be affixed at locations: (RSID) THE DC-TO-DC CONVERTER: 15A Per NEC 2017 690.12 LOCATION KEY: I AC: AC DISCONNECT SOLAR DC DISCONNECT: C: CONDUIT; INTERIOR AND EXTERIOR Label to be affixed at locations: (INV) CB: COMBINER OR JUNCTION BOX Per NEC 2017 690.53 D: DISTRIBUTION PANEL Label to be affixed at locations: (DC) DC: DC DISCONNECT Per NEC 2017 690.13(B) INV: INVERTER LC: LOAD CENTER M: UTILITY METER PCC: POINT OF COMMON COUPLING RSID: RAPID SHUTDOWN INITIATION DEVICE SOLAR PV SYSTEM EQUIPPED WITH PV SYSTEM DISCONNECT RAPID SHUTDOWN WARNING: PHOTOVOLTAIC POWER SOURCE AL (32.OAAC, 240VAC) AL TURN RAPID SHUTDOWN SWITCH TO THE "OFF" Label to be affixed at locations: (C), (CB) POSITION TO SHUT DOWN SOLAR ELECTRIC Label to be affixed at locations: AC Distance between labels 10ft Max ( ) PV SYSTEM AND REDUCE PV PANELS Per NEC 2017 690.31(G)(3) Per NEC 2017 690.13(B), 690.15 SHOCK HAZARD IN THE ARRAY Mill 9 raj"- . _ Label to be affixed at locations: (D) POWARNING: INVERTER RNING: I POWER SOURCE Per NEC 2017 690.12 UTPUT CONNECTION. SOLAR PV SYSTEM PRESENT DO NOT RELOCATE (32.OAAC, 240VAC) T IS OVER CURRENT DEVICE SYSTEM DISCONNECT ADJACENT TO ER Ir 111M POWEIrr Label to be affixed at Label to be affixed at locations: (D), (M)(PCC) ( ) SOURCES PRESEN Per NEC 2017 690.13(B), 690.54 �. Per NEC 2017 690.54 - Label to be affixed at locations: (D),(LC) Per NEC 2017 690.54 CONFIDENTIAL THE Ted Clark REVISIONS Neil Kelly Company INFORMATION CONTAINED IN CO OR CCB# 1663 THIS DOCUMENT IS THE SOLE 13890 SW 114th Ave 1\1( PROPERTY OF NEIL KELLY MM/DD/YY REMARKS 804 N Alberta St ANY REPRODUCTION USE OR 1 /_ / O Portland OR 97217 INFORMATION IS DISCLOSURE OF THIS Tigard, OR 97223 2 WA L&I# WITHOUT THE WRITTEN PROHIBITED 3 / / TEL: 503.288.7461 NEILKCI18702 CONSENT OF NEIL KELLY ------ ©2U,SNEIL KELLY CD. Drawing: Electrical Notes Date: November 1 , 2019 5 --/-/ W