Loading...
Report (2) t�?EC20� -r'032ZJ 70e? sta , Fetlx/(Z I VT UL SYSTEM NO.W-L-8071 MULTIPLE PENETRANTS THROUGH GYPSUM WALL ASSEMBLY F-RATING = 1-HR. OR 2-HR. T-RATING = 1/2-HR. FRONT VIEW E A az L A SECTION A-A O © 0 0 43 1.11 4 Sheet 1 of 2 Drawing No. 'MI,&nil.I HILTI, Inc. Scale 5132"=1" WL Tulsa,Oklahoma USA(800)879-8000 Hilti Firestop Systems Date Aug.01,2006 8071b Saving Lives through Innovation and Education /,'2 2O/ ao32z 700 9t/ owtf'1/77Z SY UL SYSTEM NO.W-L-8071 MULTIPLE PENETRANTS THROUGH GYPSUM WALL ASSEMBLY F-RATING = 1-HR.OR 2-HR. T-RATING = 1/2-HR. 1. GYPSUM WALL ASSEMBLY(UL/cUL CLASSIFIED U300, U400 OR V400 SERIES)(1-HR. OR 2-HR. FIRE-RATING) (2-HR. SHOWN). 2. [NOT SHOWN]WOOD STUDS TO CONSIST OF NOMINAL 2"x 4" LUMBER. STEEL STUDS TO BE MINIMUM 3-1/2"WIDE. 3. ONE OR MORE OF THE FOLLOWING PIPES, CONDUITS OR TUBES MAY BE INSTALLED WITHIN THE OPENING : A. MAXIMUM 2" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 2" NOMINAL DIAMETER CAST OR DUCTILE IRON PIPE. C. MAXIMUM 2" NOMINAL DIAMETER STEEL CONDUIT OR EMT. D. MAXIMUM 2" NOMINAL DIAMETER FLEXIBLE STEEL GAS PIPING (WITH OR WITHOUT PLASTIC COVERING) MANUFACTURED BY OMEGA FLEX, INC. OR WARD MFG., INC. E. MAXIMUM 1" NOMINAL DIAMETER FLEXIBLE STEEL GAS PIPING (WITH OR WITHOUT PLASTIC COVERING) MANUFACTURED BY GASTITE, DIVISION OF TITEFLEX. 4. MAXIMUM 2" NOMINAL DIAMETER ENT. 5. MAXIMUM 4" DIAMETER CABLE BUNDLE TO CONSIST OF ANY OF THE FOLLOWING : A. MAXIMUM 200 PAIR NO. 24 AWG TELEPHONE CABLE WITH PVC JACKET. B. MAXIMUM 1/C NO. 500 KCMIL COPPER CONDUCTOR POWER CABLE WITH KLPE JACKET. C. MAXIMUM 3/C (+GROUND) NO.2/0 AWG ALUMINUM CONDUCTOR SER CABLE WITH PVC JACKET. D. MAXIMUM 3/C NO. 8 AWG COPPER CONDUCTOR METAL CLAD CABLE. E. MAXIMUM 4 PAIR NO. 24 AWG COPPER CONDUCTOR COMMUNICATION CABLE. F. MAXIMUM RG/U COAXIAL CABLE WITH PVC JACKET. 6. MINIMUM 5/8" DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 7. MINIMUM 1/2" BEAD HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT APPLIED AT POINT OF CONTACT. ANNULAR SPACE MINIMUM MAXIMUM BETWEEN METALLIC PENETRANTS AND PERIPHERY OF OPENING 0" 2" BETWEEN METALLIC PENETRANTS, ENT AND CABLES 1/2" 1-1/2" BETWEEN ENT AND PERIPHERY OF OPENING 1/4" 2" BETWEEN CABLES AND PERIPHERY OF OPENING 0" 2" NOTE : MAXIMUM DIAMETER OF OPENING = 8". Sheet 2 of 2 Drawing No. 114,111.1n , HILTI,Inc. Scale WL Tulsa,Oklahoma USA(800)879-8000 Hilti Firestop Systems Date Aug.01,2006 8071b Saving Lives through Innovation and Education UL SYSTEM NO.W-L-8079 MULTIPLE PENETRATING ITEMS THROUGH GYPSUM WALL ASSEMBLY F-RATING = 1-HR. OR 2-HR. o T-RATING = 0-HR., 112-HR., 3/4-HR., 1 1/2-HR., OR 2-HR. N 0 FRONT VIEWSECTION A-A o J O O 1 —1 ,, p 0 ,J2j>>i / r • . 7 • r r r J, "it:-., 0 v ' S / Of /---141. J r r r r:_-/r r c)4 / <<C�i C I_ ;;; A 1. GYPSUM WALL ASSEMBLY(UL CLASSIFIED U300, U400 OR V400 SERIES) (1-HR. OR 2-HR. FIRE-RATING) (2-HR. SHOWN) TO INCLUDE THE FOLLOWING CONSTRUCTION FEATURES : A. [NOT SHOWN] WOOD STUDS TO CONSIST OF NOMINAL 2"x 4" LUMBER(SPACED MAXIMUM 16"OC). STEEL STUDS TO BE MINIMUM 3-1/2"WIDE (SPACED MAXIMUM 24"OC). B. NOMINAL 5/8"THICK GYPSUM WALLBOARD.TYPE, NUMBER OF LAYERS,AND SHEET ORIENTATION AS SPECIFIED IN THE INDIVIDUAL UL DESIGN. Sheet 1 of 2 Drawing No. MILT' HILTI,Inc. Scale 118"=1" WL Tulsa,Oklahoma USA(800)879-8000 Q Hilti Firestop Systems Date Feb.11,2009 8079b Saving Lives through Innovation and Education UL SYSTEM NO.W-L-8079 MULTIPLE PENETRATING ITEMS THROUGH GYPSUM WALL ASSEMBLY F-RATING = 1-HR. OR 2-HR. T-RATING = 0-HR., 1/2-HR., 3/4-HR., 1 1/2-HR., OR 2-HR. 2. ONE OR MORE OF THE FOLLOWING PIPES, AND IN ANY COMBINATION MAY BE INSTALLED WITHIN THE OPENING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE (SCH 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER CAST OR DUCTILE IRON PIPE. C. MAXIMUM 3" NOMINAL DIAMETER COPPER PIPE OR TUBING. D. MAXIMUM 3" NOMINAL DIAMETER STEEL CONDUIT OR EMT. E. MAXIMUM 2" NOMINAL DIAMETER PVC PLASTIC PIPE (SCH 40, CELLULAR OR SOLID CORE) (VENTED OR CLOSED PIPING SYSTEM). F. MAXIMUM 2" NOMINAL DIAMETER CPVC PLASTIC PIPE (SDR 13.5) (CLOSED PIPING SYSTEM). 3. [OPTIONAL] ONE OR MORE METALLIC PIPES MAY BE INSULATED WITH THE FOLLOWING TYPES OF PIPE INSULATION : A. MINIMUM 1" TO MAXIMUM 2"THICK GLASS-FIBER PIPE INSULATION (3.5 PCF DENSITY). B. MINIMUM 1/2"TO MAXIMUM 314" THICK AB/PVC PIPE INSULATION. 4. ONE MAXIMUM 3" DIAMETER CABLE BUNDLE CONSISTING OF ANY OF THE FOLLOWING : A. MAXIMUM 25 PAIR NO. 24 AWG TELEPHONE CABLE WITH PVC JACKET. B. MAXIMUM 7/C NO. 12 AWG COPPER CONDUCTOR POWER CABLE WITH PVC JACKET. C. MAXIMUM 1/2" DIAMETER FIBER-OPTIC CABLE WITH PVC JACKET. D. MAXIMUM 3/C NO. 8 AWG,WITH BARE ALUMINUM GROUND, STEEL METAL CLAD CABLE. E. MAXIMUM 3/C (WITH GROUND) NO. 8 AWG NONMETALLIC SHEATHED CABLE (ROMEX)WITH PVC JACKET. F. MAXIMUM 1/2" DIAMETER RG/U COAXIAL CABLE WITH PVC JACKET. G. MAXIMUM 3/4" DIAMETER COPPER GROUND CABLE WITH OR WITHOUT PVC JACKET. H. MAXIMUM 1-1/4" DIAMETER SINGLE OR MULTI-CONDUCTOR MINERAL-INSULATED COPPER-CLAD CABLE. 5. MINIMUM 1-1/4"THICKNESS MINERAL WOOL (MIN.4 PCF DENSITY)TIGHTLY PACKED AS A BACKER AROUND THE PERIMETER OF THE OPENING. 6. MINIMUM 3-1/2"OR 4-3/4"THICKNESS MINERAL WOOL (MIN.4 PCF DENSITY)TIGHTLY PACKED FOR 1-HR. OR 2-HR. FIRE-RATING, RESPECTIVELY. 7. MINIMUM 5/8" DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 8. MINIMUM 1/2" BEAD HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT APPLIED AT POINT OF CONTACT. NOTES : 1.WITH STEEL STUDS, MAXIMUM AREA OF SQUARE, RECTANGULAR, OR CIRCULAR OPENING IS 240 SQ. IN. WITH A MAXIMUM DIMENSION OF 20". 2.WITH WOOD STUDS, MAXIMUM AREA OF SQUARE, RECTANGULAR, OR CIRCULAR OPENING IS 210 SQ. IN. WITH A MAXIMUM DIMENSION OF 14-1/2". 3.ANNULAR SPACE BETWEEN PENETRANTS AND PERIPHERY OF OPENING = MINIMUM 0", MAXIMUM 22". 4.ANNULAR SPACE BETWEEN PENETRANTS =MINIMUM 1", MAXIMUM 22". Sheet 2 of 2 Drawing No. HILTI,Inc. Scale WL Tulsa,Oklahoma USA(800)879-8000 Hilti Firestop Systems Date Feb.11,2009 8079b Saving Lives through Innovation and Education , UL SYSTEM NO. W-L-2078 PLASTIC PIPE THROUGH 1-HR. OR 2-HR. GYPSUM WALL ASSEMBLY F-RATING = 1-HR. OR 2-HR. o T-RATING = 0, 1, OR 2-HR. N L-RATING AT AMBIENT= 3 CFMISQ. FT. og L-RATING AT 400° F = LESS THAN 1 CFMISQ. FT. FRONT VIEW SECTION A-A A c=; 0 DOW* '11! !IN 0 .1.,,,,,,11 'll ::::11 ri "Ii: .117"A hi II o A -C--g 0 0 Sheet 1 of 2 Drawing No. CD-P 'TT ' HILTI, Inc. Scale 118"=1" WL FIRESTOP SYSTEMS Tulsa, Oklahoma USA(918)252-6000 Date Dec.28,2004 2078m Saving Lives through Innovation and Education UL SYSTEM NO.W-L-2078 PLASTIC PIPE THROUGH 1-HR. OR 2-HR. GYPSUM WALL ASSEMBLY F-RATING = 1-HR. OR 2-HR. o co T-RATING= 0, 1, OR 2-HR. L-RATING AT AMBIENT = 3 CFM/SQ. FT. L-RATING AT 400° F= LESS THAN 1 CFM/SQ. FT. 1. GYPSUM WALL ASSEMBLY(UL CLASSIFIED U300, U400, OR V400 SERIES) (1-HR. OR 2-HR. FIRE-RATING) (2-HR. SHOWN). 2. (NOT SHOWN). WOOD STUDS TO CONSIST OF NOMINAL 2" x 4" LUMBER. STEEL STUDS TO BE MINIMUM 2-1/2"WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING (ALSO SEE NOTE NO. 3 BELOW): A. MAXIMUM 10" NOMINAL DIAMETER PVC PLASTIC PIPE (CELLULAR OR SOLID CORE). B. MAXIMUM 10" NOMINAL DIAMETER CPVC PLASTIC PIPE (CLOSED PIPING SYSTEM ONLY). C. MAXIMUM 6" NOMINAL DIAMETER ABS PLASTIC PIPE (CELLULAR OR SOLID CORE). D. MAXIMUM 6" NOMINAL DIAMETER FRPP PLASTIC PIPE. E. MAXIMUM 4" NOMINAL DIAMETER PVDF PLASTIC PIPE. 4. HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT: A. (OPTIONAL). MINIMUM 1/4" DEPTH OF SEALANT INSTALLED ON PIPES NOMINAL 6" AND SMALLER. B. MINIMUM 1/2" DEPTH OF SEALANT INSTALLED ON PIPES LARGER THAN NOMINAL 6". 5. HILTI CP 643N OR CP 644 FIRESTOP COLLAR WITH FASTENING HOOKS (SEE TABLE BELOW). 6. ATTACH EACH FASTENING HOOK TO WALL ASSEMBLY WITH HILTI 3/16" TOGGLER BOLTS AND WASHERS. NOMINAL PIPE PRODUCT NO. OF FASTENING MAXIMUM HOLE SIZE DIAMETER DESCRIPTION HOOKS 1-1/2" CP 643 50/1.5" N 2 2-1/8" 2" CP 643 63/2" N 2 2-5/8" I 3" CP 643 90/3" N 3 4" 4" CP 643 110/4" N 3 5" 6" CP 643 16016" N 4 7" 8" CP 644 20018" 10 9-1/2" 10" CP 644 250/10" 12 11-1/2" NOTES : 1. ANNULAR SPACE = MINIMUM 0", MAXIMUM 1/2". 2. CLOSED OR VENTED PIPING SYSTEM. (PVC, ABS, AND FRPP= SCHEDULE 40, CPVC= SDR 13.5, AND PVDF= SDR 32.5). 3. L-RATINGS ONLY APPLY ON PIPES NOMINAL 6" AND SMALLER, WHEN HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT IS USED. _ Sheet 2 of 2 Drawing No. D_n _I ' _® HILTI, Inc. Scale VVL FIRESTOP SYSTEMS Tulsa, Oklahoma USA(918)252-6000 Date •■ Dec.28,2004 2078m Saving Lives through Innovation and Education UL/cUL SYSTEM NO. F-C-1059 METAL PIPE THROUGH WOOD FLOOR/CEILING ASSEMBLY F-RATING = 1-HR. OR 2-HR. T-RATING = 0-HR. OR 1/2-HR. TOP VIEW SECTION A-A T � O © © TO O A A ''-:.-moi ,111.1110, 1.WOOD FLOOR/CEILING ASSEMBLY(UL/cUL CLASSIFIED L500 SERIES) (1-HR. OR 2-HR. FIRE-RATING) (2-HR. SHOWN). 2. LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD, OR FLOOR TOPPING MIXTURE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 6" NOMINAL DIAMETER STEEL PIPE (SCHEDULE 40 OR HEAVIER). B. MAXIMUM 6" NOMINAL DIAMETER CAST IRON PIPE. C. MAXIMUM 6" NOMINAL DIAMETER STEEL CONDUIT. D. MAXIMUM 4" NOMINAL DIAMETER EMT. E. MAXIMUM 2" NOMINAL DIAMETER FLEXIBLE STEEL CONDUIT. 4. MINIMUM 3/4" DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT FLUSH WITH TOP SURFACE OF SUBFLOOR OR SOLE PLATE. 5. HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT FLUSH WITH BOTTOM SURFACE OF CEILING OR LOWER TOP PLATE : A. MINIMUM 5/8" DEPTH OF SEALANT FORA 1-HR. FIRE-RATING. B. MINIMUM 1-1/4" DEPTH OF SEALANT FOR A 2-HR. FIRE-RATING. NOTES : 1. MAXIMUM DIAMETER OF OPENING=7-5/8". 2.ANNULAR SPACE = MINIMUM 1/4", MAXIMUM 3/4". 3. CHASE WALL(NOT SHOWN, OPTIONAL) -THE THROUGH PENETRANT MAY BE ROUTED THROUGH A 1-HR. OR 2-HR. FIRE-RATED GYPSUM CHASE WALL ASSEMBLY. Sheet 1 of 1 Drawing No. 1.41 Lair I 1 HILTI, Inc. Scale 1hr=1" FC Tulsa,Oklahoma USA(800)879-8000 Hilti Firestop Systems Date Aug.11,2008 1059h Saving Lives through Innovation and Education UL/cUL SYSTEM NO. F-C-1106 METAL PIPE THROUGH WOOD FLOOR ASSEMBLY F-RATING = 1-HR. T-RATING = 1/4-HR. TOP VIEW SECTION A-A T � 00 00 0 A A � 5 S 2 0 0 1. WOOD FLOOR/CEILING ASSEMBLY(UL/cUL CLASSIFIED L500 SERIES)(1-HR. FIRE-RATING). 2. LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD, OR FLOOR TOPPING MIXTURE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE(SCHEDULE 10 OR HEAVIER). B. MAXIMUM 4" NOMINAL DIAMETER CAST IRON OR DUCTILE IRON PIPE. C. MAXIMUM 4" NOMINAL DIAMETER COPPER PIPE OR COPPER TUBING. D. MAXIMUM 4" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4" NOMINAL DIAMETER EMT. 4. MINIMUM 3/4" DEPTH HILTI CP 606 FLEXIBLE FIRESTOP SEALANT. 5. MINIMUM 5/8" DEPTH HILTI CP 606 FLEXIBLE FIRESTOP SEALANT. 6. MINIMUM 1/2" BEAD HILTI CP 606 FLEXIBLE FIRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING =5". 2. ANNULAR SPACE = MINIMUM 0", MAXIMUM 7/8". 3. CHASE WALL(NOT SHOWN, OPTIONAL)-THE THROUGH PENETRANT MAY ROUTED THROUGH A 1-HR. FIRE-RATED GYPSUM CHASE WALL. Sheet 1 of 1 Drawing No. r — ��_ HILTI, Inc. Scale 5/32',_1„ C FIRESTOP SYSTEMS Tulsa,Oklahoma USA(918)252-6000 Date — 1-Fv July 12,2004 1106b Saving Lives through Innovation and Education