Report (2) Oregon Residential Specialty Code R318.2
MOISTURE CONTENT ACKNOWLEDGEMENT FORM
I, , am the general contractor or the owner-builder
at the following address:
Site Address: (cc cs-Lk L.4 TEL
City -
Permit#:
Subdivision/Lot#:
t 4-3
and/or
Map and Tax Lot#:
To conform with the 2008 Oregon Residential Specialty Code(ORSC), Section R318.2 and
OAR 918-480-0140, I am notifying the building official that I am aware of the moisture content
Requirement of ORSC Section R318.2 and have taken steps to meet this code requirement.
[Section R318.2 is provided for reference].
R318.2 Moisture Content: Prior to the installation of interior finishes, the building
official shall be notified in writing by the general contractor that all moisture-sensitive
wood framing members used in construction have a moisture content of not more than 19
percent by dry weight of dry framing members.
Signature: !
Date:
•.tracto or Owner-Builder
I:\BuildingTorm\RES-MolstareSensitiveWood.doc 09/25/08
Oregon Residential Specialty Code R408.1
MOISTURE BARRIER ACKNOWLEDGEMENT FORM
14-&\(-.' a, r , am the general contractor or the owner-builder
at the following address:
Site Address:
tULS—t-1
City:
Pen-nit#:
tet DDLYli
Subdivision/Lot#:
and/or
Map and Tax Lot#:
To conform with the 2014 Oregon Residential Specialty Code(ORSC), Section R408.1
Ventilation. I am notifying the building official that I have installed the Moisture Barrier as per
Requirement in ORSC Section 408.1 and have taken the following steps to meet this code
requirement:
[ ,- The ground surface of the under-floor space is covered with 6-mil black polyethylene
sheeting with
lapped 12"at seams and
rqending up the foundation walls 12".
SI
• Date: CX(10(lc(
or Owner-Builder
IABuildingWormIRES-MoistureBarner,doc 09/13/2016
Oregon Residential Specialty Code N1107.2
HIGH-EFFICIENCY INTERIOR LIGHTING SYSTEMS
Permit No.:
s/j_DICt Jurisdiction:
--TR
Site Address: „
t S-4-4(4 Sk.A kAl.)
Subdivision/Lot#:
and/or
Map and Tax Lot#:
By my signature below, I certify that a minimum of fifty(50)percent of the permanently
installed lighting fixtures in the above mentioned building have been installed with compact or
linear fluorescent, or a lighting source that has a minimum efficacy of 40 lumens per input watt.
(Oregon Residential Specialty Code N1107.2)1
Signature: 1 .111 Date:
tractor/Authoriied Agent
Print Name: nr.„.1 ',.
ORSC Section N1107.2.High-efficiency interior lighting systems. A minimum of fifty(50)percent o the
permanently installed lighting fixtures shall be installed with compact or linear fluorescent,or a lighting source that
has a minimum efficacy of 40 lumens per input watt_ Screw-in compact fluorescent'Amps comply with this
requirement
The building official shall be notified in writing at the final inspection that a minimum of fifty percent of the
permanently installed lighting fixtures are compact or linear fluorescent,or a minimum efficacy of 40 lumens per
input watt.
I:\BuildingWorms\RES-HighEfficieacyLighting.doc 07/01/08
7- - 00077iity) 7 / 63x141-1 _ch.) Q L 56, u-r-E S- c - 1•/
Form 6405 2017
Completion Certification—Site Inspection
Ti-ruNew Homes Program—Single Family
7
ofOregoro
To be completed by Verifier
CLEAResult is a Program Management Contractor for Energy Trust of Oregon,Inc.
Payment information
Incentive Payee Company Name: !William Lyon Homes IIs this payment redirected?: 1No
Builder or Company: Wiliam Lyon Homes Redirect to Name:
Verifier Payee Company Name: Performance Insulation and Energy Redirect Payee Corn
Affordable Housing No
Solar Ready Builder Incentive: No 'Solar ReadyVerifier Incl No
Site Information
Development NE River-Area 3-Med/Std Lot 1123 +.,. i,Axis ID. IREMIRate®ID
Address: 10544 ? 5CHUTEStt+t`, ..,,.. s Vim...
Street Line 2 Multi-Family 'No City: Tigard State' OR Zip: 97224
Total conditioned area(sq.ft.). 3,719 House Volume: I 33,392 Housing Type: Detached single family
Number of Stones: 13 Number of Bedrooms: 4 Foundation Type: Crawlspace
Electric Provider: Portland General Electric Gas Provider: NW Natural Gas
Solar installed None Solar Installer Name/Company:
Blue shaded fields are required for EPS sheet
Verification Type Actual Model Equipment Details&Notes
Slab Perimeter Insulation R- 0.0 Slab Under Insulation R-
Framed Floor R- 30.0 Secondary Framed Floor R- 59.0
Insulation
Above Grade Wall Insulation R- 23.0 Below Grade Wall Insulation R-
Flat Ceiling Insulation R- 49.0 Vaulted Ceiling Insulation R-
Windows Windows U- 0.3 SHGC.10.3 Total window area: 1578
Cooling Air Conditioning SEER: 0 Model#:
Primary Heating System Details AFUE 92.1 Brand Bryant
Type: Gas Fumace HSPF: Model#: 912SC48060S17'
Heating Fuel: Gas SEER:
Primary Heat
Source Comment: COP
Location: Conditioned A Outdoor Unit(for heat pumps)
ECM: No Model#: I
AHRI Certificate:7126231 #of Systems 11
Gallons: I Brand: AOSmith
Water Heater Type Heat Pump EF: 1 Model#. HPTU-BON 130
Water Heating Fuel Electric Location: !Garage or ope
Ducts and Duct Location IConditioned %ducts inside 105% ..'Duct Leakage(CFM)@ 50Pa• 1'pt2
Testing
Infiltration Air Changes per Hour(ACH)@ 50Pa: 2.26
Ventilation Type HRV/ERV Model:
Ventilation
Supply Side-Air Cyder Airflow measured or why untestable? (Roof Termination
Appliances
Refrigerator kwn/yr Model:
ENERGY STAR Diswasher kWh/yr 268 Model: FGID2466`•`A
Percent High Efficacy Interior Lighting(%) 100% Thermostat
Showerhead 1.5 GPH 1 Showerwand 1.5 GPH I Showerhead 1.6 GPH I IShowerhead 1.75 GPH 1
Notes: